User Manual and Installation Notes: UT2000 - 3000 Series Digital Storage Oscilloscopes
User Manual and Installation Notes: UT2000 - 3000 Series Digital Storage Oscilloscopes
User Manual and Installation Notes: UT2000 - 3000 Series Digital Storage Oscilloscopes
UNI-T
UNI-T
Uni-Trend Group Limited
Copyright Information
1. 2. Uni-Trend Group Limited. All rights reserved. Products of the Company have been authorized or are pending approval for patents in the Peoples Republic of China. Information contained in this manual supercedes all information in previously published versions. The Company reserves the right to change specifications and prices.
3.
4.
UNI-T
Uni-Trend Group Limited
USB Lead
UNI-T
Chapter Three: Installation guide for UT2000_3000 Series Computer Testing & Control Software ... . . . . . . . 13
1. Hardware ................13 2. Installing the driver ... ............13 3. Installing the software ..... ............27
4 . All right reserved 2007 ___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Notes on menu:
1. Document: Load waveform, save waveform, load intersection, print preview, print preview, print, exit. Function: Mathematics function: User can select the calculation method of the channels or window function.
2.
UNI-T
Uni-Trend Group Limited
Remote control: Control of the serial interface can be performed from a remote point.
UNI-T
Uni-Trend Group Limited
3. 4.
Refresh waveform: single refresh; waveform time interval setup Help: Content; About
Notes on front panel Channel status: Current status of the oscilloscope is displayed. When transmitting data, this status bar displays the current status. When the oscilloscopes status changes, so will this status bar, but you cannot use this bar to control the current status of the oscilloscope.
1. CH1: Coupling method (DC, AC, GND); Bandwidth suppression (On Off); Filter type (low-pass, high-pass, band-pass, band-stop); Digital filter (when the indicator lights up the function is ON, when the indicator lights off the function is OFF); Reverse (when the indicator lights up the function is ON, when the indicator lights off the function is OFF); Probe (1X, 10X, 100X, 1000X). CH2: Coupling method (DC, AC, GND); Bandwidth suppression (On Off); Filter type (low-pass, high-pass, band-pass, band-stop); Digital filter (when the indicator lights up the function is ON, when the indicator lights off the function is OFF); Reverse (when the indicator lights up the function is ON, when the indicator lights off the function is OFF); Probe (1X, 10X, 100X, 1000X).
2.
UNI-T
Uni-Trend Group Limited
3. 4. 5.
Sampling method; Random; Real-time; SCAN Interpolation (Yes, NO) Current activated channel (MATH; CH1; CH2)
Channel selection: CH1; CH2; MATH Deviation factor adjustment: Vertical; Horizontal Range adjustment: Voltage range; Time base range Real-time Control: Equipment selection (Serial, USB); ON/OFF (when the indicator
lights up the function is ON, when the indicator lights off the function is OFF); Data transmission (when the indicator lights up the function is ON, when the indicator lights off the function is OFF); Transmission screen (when the indicator lights up the function is ON, when the indicator lights off the function is OFF).
Reverse Mathematic function: Indicator on means reverse mathematic function is in process. Indicator off means reverse mathematic function is not in process. Mathematic function: Select with the MATH option in the function menu in the
menu bar.
Auto Refresh: Set up the refresh time interval with the waveform refresh menu in the
menu bar.
UNI-T
Uni-Trend Group Limited
UNI-T
Uni-Trend Group Limited
5.
6.
Click Series on the above screen so the oscilloscope can transmit continuously as indicated below. You can now control the oscilloscope.
7.
Note: When starting step 5 after completing step 4, you can select [Function] and then [Remote Control] in the menu bar instead of clicking [Data Interface]. The following screen will pop up to allow control of the oscilloscope but no waveform is displayed. This operation is similar to Serial Interface Controls explained below.
10
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Press OK. 2. Click the [Equipment ON/OFF] knob to turn it on. When the indicator lights up the function is ON. When the indicator lights off the function is OFF. Click the [Data Transmission] knob to turn it on. When the indicator lights up the function is ON. When the indicator lights off the function is OFF.
3.
11
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Note: This process may take several seconds. 4. Click the [Function] knob on the menu bar than select remote control. The following screen will appear. You can now control the oscilloscope.
Important: The above screen will not display waveform. Operation of this screen will be indicated in the oscilloscope. 5. At the end of operation press [CLOSE] to close this screen. To switch to USB connection follows the steps for USB connection stated above. When you have finished all operations, press [CLOSE] to switch off the UT2000_3000 Series Digital Storage Oscilloscope software, then power off the oscilloscope and disconnect the USB lead and RS-232 power cord.
12
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Chapter Three: Installation guide for UT2000_3000 Series Computer Testing & Control Software 1. Hardware
There are one USB device communication port and one RS-232 communication port for computer connection on the rear panel of the UT2000_3000 Series digital storage oscilloscope. By connecting a host (computer or control computer) to any one of the two ports, you can control the oscilloscope with the host from a remote location.
You will also see an icon prompt that says Found New hardware UT2000/3000 Series Digital Storage Oscilloscope.
A Found New hardware dialogue box will pop up in a little while, as shown below:
13
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Set up as follows: Step 1: Select [Yes, this time only] and click [Next] once. Step 2: In the Found New hardware Wizard wizard select [Install from a list or specific location (Advanced)], then click [Next].
14
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
The following screen will appear. Select [Browse]. In the popped up [Browse Folder] box, select the DSO directory in the directory where you intend to install UT2000_3000, then click [Next]. (As shown below).
15
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
The dialogue box below will appear but it will not affect the software or your computer. Click [Continue Anyway].
The system will automatically jump to the [System Restore Setup] screen and the document is copied.
16
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
The following screen will appear while the document is being copied.
Click the left arrow of [Browse] to select the directory you have defined in Step 2. If you have not defined any, find one in [Browse].
17
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
18
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Note: If no [Found New Hardware] wizard pops up on your computer screen when the computer is properly connected to the oscilloscope and the latter is powered on normally, right click [My Computer] and select [Attribute]. In the [System Attribute] dialogue box select the [Hardware] box. Click the [Device Manager] button. In the pop up [Device Manager] dialogue box, you can see a yellow UT2000/3000 icon that indicates incomplete installation.
19
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Right click your mouse and select [Update Driver Application] to pop up the [Found New Hardware] wizard. Follow step 1 to install the driver.
20
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
21
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Note: 1. The Ultra scope for UT2000_3000 Computer Testing & Control Software installation kit downloaded online must first be unzipped. 2. This software supports Windows 2000 and Windows XP. Step 2: Begin installation. The software installation wizard pops up as shown below :
22
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Step 3: Confirm that you wish to install this software. Click the [Next] button.
Step 4: Read the installation licensing agreement carefully. Select I agree with the terms and conditions of the licensing agreement, then click [Next].
23
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Step 5: Enter your user name and company name, then click [Next] once.
Step 6: Enter the installation path in the installation path field or click [Change ( )H..] to select an alternative installation path. Then click [Next] once.
24
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Step 7: Depending on your specific requirement, select [Quick installation for the current user only] or [Make quick installation applicable to all users], then click [Next] once.
25
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
26
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Step 10: When installation is complete as shown above, click [Finish (F)] once on the screen. The software has been installed in your host. If you wish to change any setup, simply click [Back (B)] once during any stage of the wizard. If you wish to stop the installation, click [Cancel] once during any stage of the wizard to quit. 3. Running the Software
There are two ways to find this software and run it on your computer.
1.
After finishing installation, a shortcut icon __________ appears on your desktop. Double click this icon to run the computer testing & control software.
2. Alternatively find the software in All Programs (P) in the Start Menu. Select the computer testing & control software and run.
27
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Uni-Trend Group Limited
Troubleshooting
1. 1 2 3 4 If the system prompts you to check serial or USB configuration when you enter [Equipment ON/OFF], take the following steps: Check whether the oscilloscope power plug is properly connected. Check whether oscilloscope ports match the testing and control software setups (Factory default: RS-232 baud rate 4800). Check whether the cable connection between module and PC is in order. After carrying out the above checks, restart the software to continue operation.
28
___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software
UNI-T
Copyright Statement
Uni-Trend Group Limited owns copyright of this User Manual. Unless with prior written authorization from the company, no individual or firm may release, publish or change any contents contained in any way whatsoever.
Thank you.
29 . All right reserved 2007 ___________________________________________________________________________________________ User Manual for UT2000_3000 Series Computer Testing & Control Software