PLATFORM The 6000/6000A Platform must be switched off and, if operating on mains, its supply cable must be unplugged
CHARGING If the instrument is tted with a battery, on connection to the mains: - if the user does not press ON within 20 seconds, the battery will go on to charge. In this case, the Charge indicator will be lit. - if the user presses the ON key, the instrument starts up and the battery will be charged during use. Once the battery is fully charged, the Charge indicator is lit. It is essential to wait until charging is complete to ensure maximum independent operating time, which may otherwise be considerably reduced
TECHNICAL ASSISTANCE
If you need assistance or have questions related to the use of this product, call or e-mail JDSUs Technical Assistance Center for customer support.
Captive screws
TABLE 1
Technical assistance centers Region Phone Number 866 228 3762 World Wide: +1 301 353 1550 +49 (0) 7121 86 1345 (Europe) +33 (0) 1 30 81 50 60 (JDSU France) +852 2892 0990 (Hong Kong) +86 10 6833 7477 (Beijing-China) [email protected]
8 9 10
BATTERY MANAGEMENT
The battery supplied with the Platform must be fully charged before use. The instructions below apply to the removable Lithium Ion (LiIon) batteries inside the battery pack. Asia and the Pacic Southeast Asia, Australia, and New Zealand Europe, Africa, and Mid-East
[email protected] [email protected]
2. Charge and On Indicators Lit in x green when the 6000/6000A Platform is turned on; in blinking green when the 6000/6000A Platform is turned off and connected to mains. 4. File Calls up the le and directory management menu, used to store les, choose a storage media.
3. System: Give access to the conguration menus of the instrument [choice of module(s)] & the conguration menus of the system (date, time). Press SYSTEM SETTINGS to congure the Platform.
5. Setup (depends of the active function) 6. Results Calls up the measurement conguration Calls up the Results page & is used to menu. analyze result
Battery housing Battery
7. Script Calls the Script function. 9. Testing indicator Lit in blinking red during a test.
8. Start/Stop (depends of the active function) Launch the acquisition. 10. Direction keys (depends of the active function) Move the cursors; modify zoom on results page; scroll through the menu in setup pages; validate a selection. 12. Menu keys Different according to the screen displayed.
SAFETY RECOMMENDATIONS
Laser safety (when laser source options are provided)
The provisions contained in two standards dene the safety procedures to be observed both by users and manufacturers when utilizing laser products: - EN 60825-1: 2001 - Safety of laser products Part 1: Classication of products, requirements and user guidelines. - FDA 21 CFR 1040.10 - Performance standards for light-emitting products Laser product Due to the range of possible wavelengths, power values and injection characteristics of a laser beam, the risks inherent in its usage vary. The laser classes form groups representing different safety thresholds. - Talkset option: Laser Class 1 - VFL option: Laser Class 2
MTS/T-BERD 6000 Getting Started Manual 760000032/00 May 2010 6 MTS/T-BERD 6000 Getting Started Manual Ref 760000032/00 May 2010 1
Due to the reduced dimensions of the optical modules, it is not possible to attach the required warning labels to them. In line with the provisions of Article 5.1 of the EN 60825-1 standard, the laser class identication labels are shown below: Ref. EN 60825-1, Edition 1.2, 2001-08 standard Class 1
CLASS 1 LASER PRODUCT
When the 6000/6000A Platform screen is exported on a remote PC, via a VNC window, click with the mouse on the upper banner on the PC screen to display a virtual control buttons bar for a few seconds.
FDA21CFR1040.10
Click on one of the buttons of this bar to get exactly the same result as when using the buttons on the front panel of the Platform. B. CENTRAL ZONE
CAUTION
Class 2
LASER INFORMATION DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT
Display the conguration or the results of measurements. The display depends on the release software installed. C. FUNCTION KEYS At the right side, rigid function keys (or tactile on option). The keys are different according to the function selected and the release software installed.
The user must take the necessary precautions concerning the optical outputs of the instrument and follow the manufacturers instructions. Measurements on optical bers are difcult to execute and the precision of the results obtained depends largely on the precautions taken by users.
AC/DC Safety
In conformance with the recommendations of standard EN 61010, the 6000/6000A Platform should be operated within the manufacturers guidelines. Failure to do so may compromise the protection offered by the instruments design. Do not use any mains adaptor or battery other than those supplied with the instrument, or supplied by JDSU as an option for this instrument. - The 6000/6000A Platform uses one Lithium ion (LiIon) rechargeable battery and a lithium coin-cell. This is a long-life battery, and its possible that you will never need to replace it. However, should you need to replace it, refer to your system documentation for instructions. - Do not dispose of the battery/coin-cell along with household waste. Contact your local waste disposal agency for the address of the nearest battery/coin-cell deposit site.
Central Zone
Function keys
1 SCREEN 2 COUNTRY 3 I/O INTERFACE 4 UTILITY 5 PRINTER 6 TOUCH SCREEN CALIBRATION 7 FACTORY DEFAULT
Allows conguration of the display: backlight, contrast, screen saver Allows conguration of the language to be used and the date / time Allows conguration of the communication interfaces between the 6000/6000A Platform and a PC Allows conguration of the options: VFL, Talkset, automatic shutdown and upgrade parameters. Allows conguration of the printing function This button allows the touch screen to be calibrated, when the option is available on the Platform. This button allows the system to be congured with the original parameters set by default in the factory.
The display is divided into 3 zones: The instrument is ready to be used once the System page or the Result page of the activated function, at the previous start, is displayed. A. UPPER BANNER Display different icons according to the commands activated. Print icon VNC icon VFL icon USB icon Talkset icon Data saving in progress Battery charge
3 MTS/T-BERD 6000 Getting Started Manual Ref 760000032/00 May 2010 4