Raritan Paragon Manual
Raritan Paragon Manual
Raritan Paragon Manual
Raritan Computer Inc. 400 Cottontail Lane Somerset, NJ 08873 USA Tel. 1-732-764-8886 Fax. 1-732-764-8887 E-mail: [email protected] http://www.raritan.com
Raritan Computer Europe, B.V. P.O. Box 566 2900 AN Capelle aan den IJssel The Netherlands Tel. 31-10-284-4040 Fax. 31-10-284-4049 E-mail: [email protected] http://www.raritan.com
Raritan Computer Japan, Inc. Kuga Building 7F 11-6, Kuramae 4-chome Taitoo-ku, Tokyo 111-0051, Japan Tel. 81-3-5833-6360 Fax. 81-3-5833-6336 E-mail: [email protected] http://www.raritan.co.jp
Raritan Computer Taiwan, Inc. 5F, 121, Lane 235, Pao-Chiao Rd., Hsin Tien Taipei Hsien, Taiwan, ROC Tel. 886-2-8919-1333 Fax. 886-2-8919-1338 E-mail: [email protected] http://www.raritan.com.tw
FCC INFORMATION
FCC INFORMATION
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential environment may cause harmful interference. Product names mentioned in this document are trademarks or registered trademarks of their respective companies. Z-Series, Paragon, MasterConsole MX4, MasterConsole MXU2, MasterConsole II, MasterConsole SMX, ConsoleSwitch and their respective logos are registered trademarks of Raritan Computer, Inc. PS/2, RS/6000, and PC/AT are registered trademarks of International Business Machines Corporation. Sun is a registered trademark of Sun Microsystems. All other marks are the property of their respective owners.
JAPANESE APPROVALS
TABLE OF CONTENTS
TABLE OF CONTENTS
CHAPTER 1: INTRODUCTION 1
PARAGON FEATURES AND ADVANTAGES _____________________________________________ 1 PARAGON SYSTEM COMPONENTS __________________________________________________ 2 PARAGON CABLE INFORMATION ____________________________________________________ 4
CHAPTER 2: INSTALLATION
QUICK START _________________________________________________________________ 7 ADMINISTRATOR USER NAME AND PASSWORD DEFAULTS _________________________________ 9 CONFIGURATION OPTIONS ________________________________________________________ 9 BASIC INSTALLATION ___________________________________________________________ 12 MULTI-TIER INSTALLATION _______________________________________________________ 18 INSTALLING A PARAGON SWITCH _______________________________________________ 19 CONNECTING TIERED RARITAN KVM SWITCHES TO A BASE PARAGON SWITCH______________ 20 Connecting a Paragon Switch as a Second Tier or Third Tier Unit ________________ 20 GUIDELINES FOR PARAGON SYSTEM CONFIGURATION ________________________________ 21 CONNECTING Z-SERIES Z4200U Z-CIMS AS A TIER _________________________________ 22 Connecting a MasterConsole MX4 as a Tier__________________________________ 28 Connecting a MasterConsole MXU2 as a Tier ________________________________ 30 Connecting a MasterConsole II (Model MCC only) as a Tier _____________________ 33 Connecting a MasterConsole P as a Tier____________________________________ 35 EXPANDED INSTALLATION OPTIONS ________________________________________________ 37 HUBPAC _________________________________________________________________ 37 CIMPAC _________________________________________________________________ 40 RACK MOUNT BRACKETS RUMT AND RUST _______________________________________ 43
47
47 48 51 52 55 56
LOGIN ______________________________________________________________________ SELECTING A COMPUTER ________________________________________________________ PUBLIC VIEW MODE ___________________________________________________________ USER CUSTOMIZATION _________________________________________________________ ON-SCREEN USER INTERFACE (OSUI) FUNCTIONS _____________________________________ PARAGON SWITCH FRONT PANEL DISPLAY AND CONTROLS ______________________________
61 63
63 64 66 68
ADMINISTRATION ______________________________________________________________ SYSTEM CONFIGURATION _______________________________________________________ USER CONFIGURATION _________________________________________________________ CHANNEL CONFIGURATION ______________________________________________________
II
TABLE OF CONTENTS
USER STATION PROFILE_________________________________________________________ 70 REFRESH CONFIGURATIONS ______________________________________________________ 71
73
HARDWARE REQUIREMENTS ______________________________________________________ 73 DOWNLOADING OVERVIEW _______________________________________________________ 73 CONNECTING A PC TO UST1 __________________________________________________ 73 OPERATING OVERVIEW SOFTWARE_________________________________________________ 74 EDITING USER PROFILES _____________________________________________________ 76 EDITING DEVICE PROFILES ____________________________________________________ 77 SAVING A COPY OF THE CONFIGURATION FILE TO A PC DISK FILE _______________________ 77 UPLOADING A CONFIGURATION FILE TO YOUR SYSTEM _______________________________ 78 DOWNLOADING A CONFIGURATION FILE FROM UST1 _________________________________ 78 OPENING A SAVED CONFIGURATION FILE FROM A PC DISK FILE _________________________ 78 TROUBLESHOOTING ____________________________________________________________ 79
81
RECOMMENDATIONS ___________________________________________________________ 82
83 85
CIM INSTALLATION: CONNECTING CIM AND SERVER ___________________________________ 87 CONNECTING UTP CABLES ______________________________________________________ 89
91
SYMPTOMS AND SOLUTIONS ______________________________________________________ 91 MULTI-TIER INSTALLATION _______________________________________________________ 92 UTP CABLING FAQS___________________________________________________________ 93
97 103
APPENDIX A: PARAGON UPDATE FIRMWARE UPGRADE _______________________________ 103 UPDATE USER STATION(S)___________________________________________________ 105 UPDATE PARAGON MATRIX SWITCHING UNIT(S) ___________________________________ 106 APPENDIX B: IBM X330 _______________________________________________________ 107
CHAPTER 1: INTRODUCTION
CHAPTER 1: INTRODUCTION
Paragon Features and Advantages
2U design supports 16 users, 64 computers (model UMT1664) 1U design supports 8 users, 32 computers (model UMT8) 1U design supports 4 users, 42 computers (model UMT442) 1U design supports 2 users, 42 computers (model UMT242) 1U design supports 2 users, 42 computers (model UMT2161) Expands to 32 users with Raritans UKVMP2 or CIMPAC8 Expands to 64 users with Raritans HUBPAC8 Locates users and computers up to 1,000 feet apart Supports high-resolution video up to 1600 x 1200 Supports up to 127 customized user profiles Adds remote access over IP or modem with Raritans TeleReach Expands to 10,000 servers with Cascade Matrix Switching Units Enclosed 19 rack mounts with included brackets Simple plug-and-play auto-configure installation Hot-swappable components with no impact on server operation Platform-specific CIMs for PS/2, Sun, USB, ASCII/serial devices Powerful, intuitive on-screen user interface for simple operation Flexible, multi-level security for authorized computer access Three system operation modes - private, public, and share Flash firmware upgrades PC Windows program to maintain Paragon database offline OSUI support for IBM x330 with C2T technology Seamless compatibility with Raritans MasterConsole MXU2 and Z-Series 4200U
Located at each computer Contains transmitter for Category 5e signals and programmable ID memory for auto-configuration Please refer to Specifications on page 85 for a complete description of Computer Interface Modules (CIMs)
Local user console Connections for User Console keyboard, monitor, and mouse RJ45 connection to Paragon Matrix Switch
CHAPTER 1: INTRODUCTION
A complete Paragon setup may be configured as shown:
Up to 32 PCs
CIMs
Cat5E Cable
ESC
FUNC
ENT
Cat5E Cable
Each Paragon switch (UMT2161, UMT242, UMT442, UMT8, or UMT1664) ships with: Two 30 foot Category5e UTP test cables (Part # UCC030) Administrators Installation and Operation Guide Quick Setup and Installation Guide AC Power Cord Admin cable Video terminator (Part # VT100) (with models UMT8 and UMT1664 only)
Each Paragon User Station (UST1) ships with: User Manual AC Power cord Monitor AC power extension cord
When using certified cable, users can transmit video signals at distances up to 1,000 feet at 1024x768 @75Hz; and up to 600 feet at 1600x1200 @75Hz. Use of non-certified cabling can result in video and data degradations that users may find unsatisfactory. Certified Raritan cable products listed above are widely available and competitively priced.
Note: Raritan does not have any marketing relationship with Belden, nor does Raritan receive any financial incentive for recommending Belden products. Please refer to UTP Cabling FAQs on page 93 for more information on Raritan certified cables.
CHAPTER 1: INTRODUCTION
Category 5e Unshielded Twisted Pair (UTP) Cable Mod Plug Requirements for use with Raritan Category 5e UTP Products
T568A
Mod Plug Positions White/Green
T568B
Mod Plug Positions White/Orange
1 2 3 4
Cat 5e Cable
1 2 3 4 5 6 7 8
R J 4 5 C O N N E C T O R
R J 4 5 C O N N E C T O R
Cat 5e Cable
5 6 7 8
CHAPTER 2: INSTALLATION
CHAPTER 2: INSTALLATION
Quick Start
Important: All computers and Paragon components must be powered OFF prior to installation.
Physical Connections: 1. Connect power cord to the Paragon Switch and power ON the unit. Note: Step 2 applies to models UMT8 and UMT1664 only. When working with other units, please skip directly to step 3. 2. 3. 4. 5. 6. 7. 8. 9. Connect VT100 Terminator into top Expansion Port on back of the switch. Connect one end of a Category 5e UTP cable to User Port # 1 on back of the Paragon switch. Connect the other end of cable to RJ45 Cat5 Port on back of User Station (UST1). Connect power cord to User Station (UST1). Power ON UST1. Connect a PS/2 keyboard, mouse and VGA monitor to UST1. Power ON monitor. Connect one end of a Category 5e UTP cable to Channel Port #1 on back of Paragon Switch.
10. Connect the other end of cable to RJ45 port on a Computer Interface Module (CIM). 11. Connect CIM to servers keyboard, video, and mouse ports. 12. Power ON Server.
8
Administrative Setup: 1. 2.
At the Login Menu, displayed at the User Console attached to the UST1, type admin (all lowercase) in the User Name field and press <Enter>. Type raritan (all lowercase) in the Password field and press <Enter>. The monitor displays an On-Screen User Interface (OSUI) Selection Menu with the connected computer displayed in green. Use the <!> or <"> keys to highlight the channel highlighted in green and press <Enter>. Normal computer access and operation indicates a successful connection.
3. 4.
Important: The above steps for a Quick Start can be repeated with all UST1 and CIM units. For more detailed installation instructions, please refer to the rest of this chapter.
Note: A video gain adjustment is available to focus the video image, which may be necessary when using LCD flat panel monitors. Activate the OSUI by rapidly hitting the default Hot Key activator (the <Scroll Lock> key) twice and use the numeric keypad + and - keys to adjust the video image until it appears in focus.
CHAPTER 2: INSTALLATION
User Names: If user names have not been assigned, the default names are user01 through user07 for users, and admin for the administrator. User names are not case sensitive. Passwords: If a password is necessary, you will be prompted to enter one. The administrators password is raritan typed in lowercase. Passwords are case sensitive.
Configuration Options
Basic Installation: Depending on the Raritan model you are working with, you can configure your system for a specific number of users to access up to a specific number of computers:
Multi-Tier Installation: For expanded access, tier multiple Raritan Paragon switches with other Raritan KVM switches for expanded access. Your system can be set up with one base and up to two tier levels. Installation requires basic operation of Paragons On-Screen User Interface (OSUI) menus. Activate the OSUI by rapidly hitting the default Hot Key activator (the <Scroll Lock> key) twice.
10
Menu Title
!
Scan
Skip
NCSH '
1. 2. 3. 4. 5. 6. 7.
Title Line Menu/Screen Body (for text and fields) Scrolling Messages Banner Status Line, which displays: Current OSUI (On Screen User Interface) hot key activator in this case, the <Scroll Lock> key pressed twice rapidly will call the OSUI menu Scan/Skip status - if highlighted in yellow, option is on, if highlighted in white, option is off. <Num Lock> (N), <Caps Lock> (C), and <Scroll Lock> (S) status indicator, followed by Paragon Communication Speed Indicator for low (L) or high (H). The Paragon Communication Speed Indicator displays the communication speed between a User Station (UST1) and a Paragon Switch (UMT2161, UMT242, UMT442, UMT8, or UMT1664). Communication will be at low speed, indicated by the letter L, or at high speed, indicated by the letter H. Speed can depend upon the versions of your Paragon components.
CHAPTER 2: INSTALLATION
11
Function Keys: <F1>, <F2>, <F4>, and <F8> are used to switch among first-level menus. Pressing <F1> while OSUI is active invokes the Help Screen, which details all available options. Whenever the OSUI is invoked, the user console keyboards <Scroll Lock> LED indicator blinks repeatedly.
Help
F1 Help / ESC Exit F2 Channel Selection / Name - F12 Sort by Channel F4 User Profile F5 Administrative Functions F6 Toggle Scan On/Off F7 Toggle Skip On/Off F8 Information Screen F9 Logout - Shft+F9 Release Channel F10 Toggle Disp All Ch. On/Off .. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
Please refer to Operating Paragon on page 47 for a more information on Paragons OSUI.
12
Basic Installation
A predetermined number of users can access up to a certain number of computers through the following Raritan models:
COMPUTERS:
Please use the steps that follow to perform a Basic Installation of a single tier system: Important: Power OFF all computers and Paragon components prior to installation. 1. Initialize Paragon Switch (UMT2161, UMT242, UMT442, UMT8, or UMT1664).
a.
Connect power cord to the Paragon Switch and power ON switch. Note: Step (b) applies to models UMT8 and UMT1664 only. When working with other units, please skip directly to step (c).
b. Connect VT100 Terminator into top Expansion Port on back of the Paragon Matrix Switch.
Note: Installing the VT100 adapter into the top Expansion Port on the back panel of the Paragon Matrix Switch will improve video quality. A VT100 adapter should be installed on each UMT8 and UMT1664 switch in your configuration. UMT2161, UMT242, and UMT442 models do not require installation of the VT100 adapter.
c.
Wait for self-testing (visible on the front panel LCD of the switch) to complete. Unit is ready when first line of LCD on front of switch circulates the message shown below. /1 refers to the UMT8 switch main unit.
CHAPTER 2: INSTALLATION
Note: The Paragon Matrix Switching Units Expansion Ports reserve a location for the future implementation of Raritan Banking Technology, an improved KVM configuration design that conceivably banks or links Matrix Switching Units directly to each other. UMT2161, UMT242, and UMT442 models do not include Expansion Ports.
13
Important: Step 2, below, is optional when installing a UMT2161 unit. The UMT2161 can be connected to a UST1 OR directly to a keyboard, a monitor, and a mouse OR both a UST1 and directly to a keyboard, a monitor, and a mouse. If you are connecting the UMT 2161 to a UST1, please follow step 2. If you are not installing a UST1, but instead are connecting the UMT2161 directly to a keyboard, a monitor, and a mouse, please skip to step 3. 2. Connect User Station (UST1).
a. b. c. d.
Connect one end of a Category 5e UTP cable to User Port # 1 on the back of the switch. Connect the other end of cable to RJ45 Cat5 Port on back of UST1. Connect power cord to User Station (UST1) and power ON UST1. Connect a PS/2 keyboard, mouse, and VGA monitor to UST1 and power ON monitor.
14
3.
a. UST1 will establish communication with the Paragon Switch. b. A Login Menu appears on user console monitor. The <Scroll Lock> LED on the keyboard
blinks to indicate Hot Key mode is operational, which enables keyboards communication with the Paragon OSUI for performing login, computer selection, and administrative functions.
c. Type admin in the User Name field and press <Enter>. d. Type the default password raritan (all lowercase) in the Password field and press <Enter>. e. The monitor displays the OSUI Selection Menu, indicating correct installation of UST1.
Selection Menu
UMT8 Switch HWII 1/4 No Ch. ID
-----------------
--------------------------------------------------
1 2 3 4 5 6 7 8
01 02 03 04 05 06 07 08 NT4.0 Mail Wins95.Bob ! Wins98.Jack MX4-Wing.2 NT4.0-Fax MC2-16.Reg1 UMT8 Switch-Wing.4 .. Scrolling Messages Banner.. | Scan | Skip |
03 03 03 03 -03 ---
ScrlLock
NCSL
CHAPTER 2: INSTALLATION
Note: If user console monitor displays a message ...No Connection to Paragon , UST1 is not properly connected to the switch. Check for loose connections and use only the recommended UTP cables (see UTP Cabling FAQs on page 93 for further information). 4. 5. Repeat steps 2 and 3 for each UST1 to be connected to the Paragon Switch user ports. Connect CIM / Computer.
15
a.
Connect CIM to servers keyboard, video, and mouse ports (using part # APSAT for AT-style PCs if needed) and power ON computer. The blinking green LED on CIM indicates proper functioning. b. Connect one end of a Category 5e UTP cable to Channel Port #1 on back of switch. c. Connect the other end of cable to RJ45 port on a Computer Interface Module (CIM). d. Power ON server.
Note: Please refer to Specifications on page 85 for available CIM types, functions, and any special installation instructions that apply for each CIM unit.
16
6.
a.
Assign a meaningful name for each channel (computer) by pressing <F5> to bring up the Administration Menu.
Administration Menu
Choose Admin Function ---------------------------------------------------------1 System Configuration 2 User Configuration 3 Channel Configuration 4 Keyboard Type -- English 5 Refresh Configurations .. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
b. Use the <!> or <"> keys to highlight the Channel Configuration submenu and press
<Enter> to open the menu.
UMT8 Switch HWII Scn Page: Ch ID Name ---------- ------------------------------------------ ---------1 03 2 NT4.0 Mail 03 3 Wins95.Bob 03 4 Wins98.Jack 03 5 MX4-Wing.2 -6 NT4.0-Fax 03 7 MC2-16.Reg1 -8 UMT8 Switch-Wing.4 -.. Scrolling Messages Banner.. ScrlLock | Scan | Skip |
Channel Configuration
NCSL
CHAPTER 2: INSTALLATION c. d. e. f.
17
Use the <!> or <"> keys to highlight the Name field that corresponds with the Channel ID (Ch ID) where the CIM / Computer was just installed, then press <Enter> - the yellow highlight will turn light blue. Edit name and press <Enter> when finished - the highlight will turn green as you begin to type. Press <S> to save the new name. Press <F2> to return to the Selection Menu and verify that the new name appears on the Selection Menu in green.
7.
18
Multi-Tier Installation
Paragons channel capacity can easily be expanded with a tiered installation. Up to three tiers are possible: a base plus a maximum of two levels of tiered KVM switches. When setting up two tiers, the base unit must be a Paragon switch and the second tier can be any of the Raritan KVM Switches listed below. In a three-tier configuration, both the base unit and the second tier must be Paragon Switches; the third tier can be any of the Raritan KVM Switches listed below. Raritan KVM switches that can be tiered off of a Paragon Switch unit include: other Paragon Switches, Z-Series Z4200U, MasterConsole MX4, MasterConsole MXU2, and MasterConsole II (Model MCC). Up to 2,048 computers can be accommodated with a multi-tier installation. Only computers may be connected to channel ports of the final tier KVM switches.
Important: In multi-tier configurations, the order of powering ON is critical to proper function. Last tier switches must be powered ON before the intermediate level of tier Intermediate tier switches must be powered ON before the base Paragon switch can be powered ON. User Stations (UST1s) can be powered ON and OFF at any time as needed. There is a five-second ON/OFF down time in the UST1 or Paragon power cycle.
CHAPTER 2: INSTALLATION
19
Up to 4 channels
Up to 2 channels
1 channel
1 channel
Up to 4 channels
Up to 2 channels
20
Verify and Save Changes: 1. 2. 3. 4. 5. Press <F2> at the Selection Menu to validate that the second-tier Paragon switch is properly established (all Paragon switch paths should be displayed in purple). Press <F5> to go to the Administration Menu and select the Channel Configuration submenu. Select a channel that has been configured for the Paragon Switch. Press <G> to bring up the Channel Configuration menu to edit computer names. Press <S> to save the new configuration. Press <F2> to go to the Selection Menu to validate that second-tier Paragon Switch is properly configured. Select one Paragon Switch channel and press <Enter> to go to selection menu. Select one Paragon Switch channel and press <Enter> to verify proper access to selected computer.
CHAPTER 2: INSTALLATION
21
2. 3. 4.
22
Cat 5e
Cat 5e
Ca t5 e
Cat 5e
UKVMSPD
Z-CIMs
P D MS V UK
D MSP U KV
D MSP KV U
IN OUT PC
Last Z-CIM
Z-CIM
UKVMSC
Z-CIMs Up to 42
Servers Up to 42
Back of UMT8
Note: All Paragon switches shipped from Raritan after January 1, 2002, are hardware and firmware enabled to support connection to a chain of Z4200U Z-CIMs.
Important: Z-Series installation requires that each computer be assigned a channel name as it is added to the Z4200U Z-CIM chain. Computer channels are organized alphabetically by assigned name (or the default name, which is the Z-CIMs serial number), rather than in the order of their placement within the Z4200U Z-CIM chain. It is recommended that installers assign channel names before connecting all computers to eliminate any difficulty in locating the respective channel for each computer.
CHAPTER 2: INSTALLATION
Note: When following the installation and configuration instructions below, sort the Selection Menu by Channel ID Number, not by Name. Display the menu by pressing < F2> and change the sorting method by pressing <F12>.
23
Important: All Paragon components must be powered ON prior to Z-Series tier installation. All computers in the Z-chain and all Z4200U components must be powered OFF prior to installation. Connect Z-Series Z4200U Z-CIMs as a Tier: 1. 2. 3. Connect a Category 5e UTP cable to the channel port on the Paragon switch reserved for the ZCIM chain. Connect the other end of this Category 5e UTP cable to the UTP OUT port on a Z-CIM, which will be the first Z-CIM in the chain. Connect a computer to the first Z-CIM. For UKVMSPD Z-CIM: a. Connect the 6-pin mini-DIN keyboard and mouse and HD15 video connectors on the UKVMSPD Z-CIM to computers keyboard, mouse, and video ports. b. Place the Z-CIM Terminator in the Z-CIMs UTP IN port. c. Power ON computer.
a. b. c. d.
For UKVMSC Z-CIM with local port: Connect DB25 male end of CCPnn cable to DB25 female port on back of a Z-CIM (UKVMSC). Connect other end to computers keyboard, video, and mouse ports. Place the Z-CIM Terminator in the Z-CIMs UTP IN port. Power ON computer.
24 e.
PARAGON ADMINISTRATORS INSTALLATION AND OPERATION GUIDE Optional: Connect a local user console to the UKVMSC Z-CIM.
Front of UKVMSC
Perform Channel Configuration: 1. 2. 3. 4. 5. 6. At a User Station Login Menu, type admin in the User Name field and press <Enter>. Type raritan (all lowercase) in the Password field and press <Enter>. Press <F5> to go the Administration Menu and select the Channel Configuration submenu. Use the <!> and <"> or the <Page Up> and <Page Down> keys to highlight the Paragon channel where the Z-CIM was just added. Ensure that the Device field reads Zseries. If Zseries does not appear in the Device field:
a.
Press <Tab> until the Device field is active, them press <Enter> - the highlight will turn green. b. Use the <!> and <"> keys to change device type to Z-Series and press <Enter> - the green highlight will return to yellow. c. Press <S> to save the change, or press <Esc> to exit without saving. 7. If a more descriptive name is desired:
a.
Hold the <Shift> key and press <Tab> to go back to the Name column, then press <Enter> - the highlight will turn blue. b. Edit the default name and press <Enter> - the highlight will turn green as you begin to type. c. Press <S> to save the change, or press <Esc> to exit without saving. 8. Press <F2> to go to the Selection Menu to validate that the second-tier Z4200U Z-CIM is properly configured. Select the tiered Z4200U Z-CIM device and press <Enter>.
CHAPTER 2: INSTALLATION
Name the Computer Channel on the Z4200U tiered Selection Menu: 1. 2. 3. 4. 5. When viewing the Paragon Selection Menu or any OSUI menu, press <F5> to go to the Administration Menu. Select the Channel Configuration submenu. Select the Z4200U device channel. Press <G> to bring up a Channel Configuration menu for the Z4200U chain.
25
Use the <!> and <"> keys to highlight the Name field of the computer just connected via Z4200U Z-CIM. The channel for this computer is displayed in green, and the highlight will turn yellow when it is selected. Press <Enter> - the highlight will turn blue. Type the desired computer name - the highlight will turn green as you begin to type. Press <Enter> - the highlight will turn yellow. Press <S> to save the new name.
6. 7. 8. 9.
Verify and Save Changes: 1. 2. 3. 4. Press <F2> to return to the Selection Menu. The Selection Menu will display with the new computer name highlighted in white. Press <Enter> to switch to this selected computer. Normal computer access and operation indicates a successful connection.
26
Important: Repeat the steps on the previous pages: !Connect Z-Series Z4200U Z-CIMs as a Tier !Perform Channel Configuration !Name the Computer Channel on the Z4200U tiered Selection Menu !Verify and Save Changes for each server to be added to the chain. Name and test each computer as it is added. Follow the steps below to build the rest of the Z4200U chain of servers. Attach Z4200U Z-CIM to Computer to be Added: For UKVMSPD Z-CIM: 1. Connect the 6-pin mini-DIN keyboard and mouse and HD15 video connectors on the UKVMSP Z-CIM to computers keyboard, mouse, and video ports.
For UKVMSC Z-CIM with local port: 1. Connect CCPnn cables 6-pin mini-DIN and HD15 connectors to computers keyboard, mouse, and video ports. 2. Connect DB25 male end of CCPnn cable to DB25 female port on back of Z-CIM (UKVMSC).
Attach new Z-CIM to the existing Z4200U chain: 1. 2. 3. 4. 5. Remove Z-CIM Terminator from the last Z-CIMs UTP IN port and set aside. Connect a Category 5e UTP cable to UTP IN port on the Z-CIM that is currently last in the chain. Connect the other end of this Category 5e UTP cable to the UTP OUT port on the next ZCIM/computer currently being added to the chain. Place the Z-CIM Terminator in the added Z-CIMs UTP IN port. Power ON computer.
CHAPTER 2: INSTALLATION
6. Optional: Connect a local user console to the UKVMSC Z-CIM.
27
Front of UKVMSC
Name Computer: 1. 2. 3. 4. 5. At the Selection Menu, press <F5> to go to the Administration Menu. Select the Channel Configuration submenu. Select the Z4200U device channel. Press <G> to bring up a Channel Configuration menu of the Z4200U chain. Use the <!> and <"> keys to highlight the Name field of the computer just connected via ZCIM. The channel for this computer is displayed in green, and the highlight will turn yellow as you select it. Press <Enter> - the highlight will turn blue. Type the desired computer name - the highlight will turn green as you begin to type. Press <Enter> - the highlight will turn yellow. Press <S> to save the new name.
6. 7. 8. 9.
Verify and Save Changes: 1. 2. 3. 4. Press <F2> to return to the Selection Menu. The Selection Menu will display with the new computer name highlighted in white. Press <Enter> to switch to this selected computer. Normal computer access and operation indicates a successful connection.
28
PARAGON ADMINISTRATORS INSTALLATION AND OPERATION GUIDE Connecting a MasterConsole MX4 as a Tier
Set MX4 User Port as a Second Tier Port: 1. 2. 3. 4. 5. 6. Hold the MX4s front panel [FUNC] button down when powering ON the MX4. This will cause the MX4 unit to reset to factory defaults. From the MX4 front panel, press [FUNC] to invoke the Function Menu. Use the <!> and <"> keys to go to the Set Tier function, then press <Enter> Use the <!> and <"> keys to select the proper User Port number. Press <$> to set user port as a second-tier port (T), then press <Enter> Repeat above steps for all User Ports to be connected to the base Paragon Switch.
Connect an MX4 Tiered User Port to a Base Paragon Switch: If using CIM UKVMC: 1. 2. 3. Use a cascade cable (CCPnnE) and connect DB25 connector (female) into one of the user ports designated to be the tier. Connect the cables other DB25 (male) into the DB25 connector on the UKVMC. Repeat above steps to connect remaining tier MX4 user ports to channels reserved on base Paragon switch. Connect the UKVMP keyboard, monitor, and mouse cables into the MX4 CCPnnF user cable. Connect a Category 5e UTP cable between the CIM and one of the 4 channels reserved for MX4 on base Paragon switch. Repeat above steps to connect remaining tier MX4 user ports to channels reserved on base Paragon switch.
Perform Channel Configuration: 1. 2. 3. 4. 5. 6. 7. 8. 9. At a User Station Login Menu type admin in the User Name field and press <Enter>. Type raritan (all lowercase) in the Password field and press <Enter>. Press <F5> to activate the Administration Menu. Use the <!> and <"> keys to select Channel Configuration and press <Enter>. Use the <!> and <"> or <Page Up> and <Page Down> keys to go to channels in which MX4 paths are connected. Use the <Tab> key to move to the Device Column. Press <Enter> - the highlighted area turns green. Use the <!> and <"> keys to set to MX4, MX4-8, MX4-16, or MX4-32 and press <Enter> to save the change. Hold the <Shift> key and press <Tab> to return to the Name column.
10. Press <Enter> and edit the default name. 11. Press <Enter> to retain change.
CHAPTER 2: INSTALLATION
29
12. Repeat these channel configuration steps for each path. You must name all MX4 paths with the same name. This will notify Paragon that these paths are connected to the same MX4. 13. Press <S> to save the new configuration. Verify and Save Changes: 1. 2. Press <F2> to go the Selection Menu to validate that the second-tier MX4 is properly established. All MX4 paths should be displayed in purple. Press <F5> to go to the Administration Menu and select the Channel Configuration submenu. Select a channel that has been configured for MX4. Press <G> to bring up a Channel Configuration menu for the MX4. Edit the computer names. Press <S> to save the new configuration. Press <F2> to go to the Selection Menu to validate that second-tier MX4 is properly configured. Select one MX4 channel, then press <Enter> to go to MX4 selection menu. Select one MX4 channel and press <Enter>. Verify proper access to selected computer.
3. 4.
30
PARAGON ADMINISTRATORS INSTALLATION AND OPERATION GUIDE Connecting a MasterConsole MXU2 as a Tier
Configure the MasterConsole MXU2 Unit as a Second Tier Device: 1. Attach a user console to the MXU2 unit that will be used as a second tier unit.
a.
Connect user console to appropriate ports on back of MXU2 keyboard to port labeled Keyboard (6-pin mini-DIN Female), mouse to port labeled Mouse (6-pin mini-DIN Female), and monitor to port labeled Monitor (HD15 Female). b. Plug in monitor power cord and turn on monitor. 2. Power on the MXU2 and login.
a. b. c. d. e.
Connect power cord to back of MXU2 unit and AC power outlet. Power ON the MXU2 via the power switch on the back of the unit. The Login Menu will appear on the monitor. Type admin in the User Name field of the Login Menu and press <Enter>. Type raritan (all lowercase) in the Password field, and press <Enter>. The Selection Menu will appear.
CHAPTER 2: INSTALLATION
3. Set up the MXU2 as a second tier unit.
31
a. At the Selection Menu, press <F5> to access the Administration Menu. b. Highlight selection number 1. System Configuration and press <Enter> to access the
System Configuration Menu.
System Configuration
--------------------------------------------------------UMT8 Switch HWII No 05 Device ID:
Minutes
Operation Mode: Private P-View Admin Silent: No PC Share Timeout: 01 Sec Login Blank: Off 05 Minutes Allow Blank Password: No Default Login Name Blank: Yes .. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
c.
To set each second tier User Port to Yes, press the <Tab> key or hold the <Shift> key and press <Tab> to navigate to the User 1-2 Tier: field. The First Entry in this field applies to User Port 1 and the second entry applies to User Port 2. d. Press <Enter> to edit each user tier field - the highlighted area turns green. e. Use the <!>, <">, <$>, and <#> keys to select Yes for each User Port that will be connected as a second tier. f. Press <Enter> when finished - the field turns yellow. g. Press <S> to save the changes. The MXU2 is now programmed for second tier use. h. Power off the MXU2 via the power switch in the back of the unit. i. Disconnect the user console from this MXU2 second tier unit. Connect MasterConsole MXU2 to the Paragon Switch. 1. 2. Connect a Category 5e UTP cable to each of the channels reserved for the MXU2 on the base Paragon switch. Connect the other end of this Category 5e UTP cable to the second tier MXU2 user port(s). For MXU2 User 1 (Local User Console Port):
a. Connect the other end of the Category 5e UTP cable to UKVMPs RJ45 port. b. Connect the UKVMPs 6-pin mini-DIN and HD-15 connectors to the appropriate keyboard, monitor and mouse ports of the MXU2 User 1 port.
32 a.
Connect the other end of the Category 5e UTP cable to the RJ45 User 2 port on the back of the MXU2.
Perform Channel Configuration: 1. 2. 3. 4. 5. 6. 7. 8. 9. At the User Station Login Menu, type admin in the User Name field and press <Enter>. Type raritan (all lowercase) in the Password field and press <Enter>. Press <F5> to go the Administration Menu and select the Channel Configuration submenu. Use the <!> and <"> or the <Page Up> and <Page Down> keys to select the channel where MasterConsole MXU2 is connected. Press the <Tab> key to advance to the Device field, then press <Enter> - the highlight turns green. Use the <!> and <"> keys to change the device type to a MasterConsole MXU2 (MXU28 or MXU216). Hold the <Shift> key and press <Tab> to go back to the Name column. Press <Enter> and edit the default name. Press <S> to save the new configuration.
Verify and Save Changes: 1. Press <F2> to go to the Selection Menu to validate that second-tier MasterConsole MXU2 is properly configured. Select and switch to one of the MasterConsole MXU2 channels to ensure proper switching. Press <F5> to go to Administration Menu. Select Channel Configuration submenu. Select the MasterConsole MXU2 channel. Press <G> to bring up a Channel Configuration menu of the MasterConsole MXU2. Edit names. Press <S> to save the new configuration.
2.
3.
33
Connect MasterConsole II to the Paragon Switch: If using a CIM UKVMC: 1. Use a CCPnn cable to connect keyboard, monitor, and mouse connectors to user ports on MasterConsole II. 2. 3. Connect DB25 connector to UKVM. If using the user port of a MasterConsole X model for second-tier connection:
a. Connect a RKVM module to the MasterConsole X model with a CVnn cable. b. Connect a CIM cable to keyboard, monitor, and mouse ports of RKVM module.
4. 5. Connect a Category 5e UTP cable to the CIM. Connect the other end of the Category 5e UTP cable to the channel port reserved on the base Paragon switch.
If using a CIM UKVMP: 1. Connect keyboard, monitor, and mouse cables to MasterConsole II user port. 2. If using the user port of a MasterConsole X model for second-tier connection:
a. Connect a RKVM module to the MasterConsole X model with a CVnn cable. b. Connect a CIM cable to keyboard, monitor, and mouse ports of RKVM module.
3. 4. Connect a Category 5e UTP cable to the CIM. Connect the other end of the Category 5e UTP cable to the channel port reserved on the base Paragon switch.
Perform Channel Configuration: 1. 2. 3. 4. 5. 6. 7. 8. At a User Station Login Menu, type admin in the User Name field and press <Enter>. Type raritan (all lowercase) in the Password field and press <Enter>. Press <F5> to go to the Administration Menu, then select the Channel Configuration submenu. Use the <!> and <"> or the <Page Up>and <Page Down> keys to select the channel in which MasterConsole II is connected. Use the <Tab> key to advance to the Device field and change the device type to a MasterConsole II (MasterConsole II-4, MasterConsole II-8, MasterConsole II-16). Hold the <Shift> key and press <Tab> to go back to the Name column. Press <Enter> and edit the default name. Press <S> to save the new configuration.
34
Verify and Save Changes: 1.
2.
3.
35
Note: All tier MasterConsole P models must be MasterView ready. To determine whether your MasterConsole P model is MasterView ready, check the white label on the bottom of the unit. Locate units firmware version: MDSP-nnn. If firmware version is MCSP1AC or higher (e.g., MDSP-1AD), the unit is MasterView ready. Some MasterConsole P models that are not MasterView ready can be upgraded to MasterView Ready. Please contact Raritan Technical Support for details and pricing.
Important: Connecting a MasterConsole P as a Tier is Not Recommended. This connection should be verified as to the level of user satisfaction prior to continuing. Note: As a tier device to Paragon, MasterConsole P model can be single bank only. Connect MasterConsole P to a Base Paragon Switch: If using a CIM UKVMC: 1. 2. 1. 2. 3. Use a CCPnn cable to connect keyboard, monitor, and mouse connectors of cable into keyboard, monitor, and mouse ports of MasterConsole P unit. Connect DB25 connector into UKVMC. Connect keyboard, monitor, and mouse cables to MasterConsole P user port. Connect Category 5e UTP cable to RJ45 port on UKVMP. Connect other end of Category 5e UTP cable to channel port reserved on base Paragon switch.
Perform Channel Configuration: 1. 2. 3. 4. 5. 6. 7. 8. At the User Station Login Menu type admin in the User Name field and press <Enter>. Type raritan (all lowercase) in the Password field and press <Enter>. Press <F5> to go to the Administration Menu, then select the Channel Configuration submenu. Use the <!> and <"> or <Page Up> and <Page Down> keys to select a channel in which MasterConsole P is connected. Press <Tab> to advance to the Device field and change the Device Type to the specific MasterConsole P model. Hold the <Shift> key and press <Tab> to go back to the Name column. Press <Enter> and edit the Name field. Press <S> to save new configuration.
36
Verify and Save Changes: 1.
2.
3.
CHAPTER 2: INSTALLATION
37
Installing a HubPac The Basic Installation instructions that follow will assist you in creating a 32 user Paragon Matrix Switching configuration.
Cat 5e Cable
UMT8
ESC
FUN C
ENT
ESC
FUN C
EN T
ESC
FUNC
EN T
ESC
FUN C
EN T
Cat 5e Cable
USTI
(1-8)
(1-8)
(1-8)
(1-8)
(Users 1-8)
(Users 9-16)
(Users 17-24)
(Users 25-32)
38
Important: Prior to installation, all Paragon switch units and HubPac units must be powered OFF. Computers and User Stations (UST1s) to be connected can be powered ON. Connect one HubPac to a Paragon Switch model UMT8, creating a 32 user by 8 server configuration: 1. Attach server(s), via CIM, to HubPac.
Connect CIM to server. Please refer to Specifics for Installation of CIM on page 87 for more information. b. Connect one end of a Category 5e UTP cable to RJ45 port on CIM. c. Connect the other end of cable to the RJ45 1-IN port on back of HubPac. d. Power ON server. e. Repeat above steps to connect the remaining servers, connecting the Category 5e UTP cable to the HubPac at the RJ45 2-IN, 3-IN, 4-IN, 5-IN, 6-IN, 7-IN, and 8-IN port for each consecutive server (2 through 8) added.
Note: Up to 8 servers can be connected to one HubPac. Each 5-port cluster on the HubPac represents one server connection, with four associated HubPac user ports. When each HubPac user port in a cluster is attached to a separate Paragon switch, 32 users (4 HubPac user ports x 8 users per Paragon switch) can have access to each server. 2. Connect HubPac to each Paragon Matrix Switch by repeating all of the following steps for each 5port cluster on HubPac:
a.
a. Connect one end of a Category 5e UTP cable to the RJ45 X-1 port on back of HubPac. b. Connect the other end of the cable to channel port # X on the back of Paragon Matrix Switch number 1. c. Connect one end of a Category 5e UTP cable to the RJ45 X-2 port on back of HubPac. d. Connect the other end of the cable to channel port # X on the back of Paragon Matrix Switch number 2. e. Connect one end of a Category 5e UTP cable to the RJ45 X-3 port on back of HubPac. f. Connect the other end of the cable to channel port # X on the back of Paragon Matrix Switch number 3. g. Connect one end of a Category 5e UTP cable to the RJ45 X-4 port on back of HubPac. h. Connect the other end of the cable to channel port # X on the back of Paragon Matrix Switch number 4.
Note: There are 8 five port clusters on the HubPac. For each cluster the number in front of the RJ45 IN port represents the cluster number. For example, cluster 1s first RJ45 port is 1 IN, cluster 2s is 2 IN, etc. In the instructions below, X represents the cluster number (1 through 8). 3. 4. Connect power cord to back of HubPac and power ON HubPac A HubPac represents 8 servers, and utilizes 8 channels on Paragon Matrix Switch connected. Since 32 channels are available on Paragon Matrix Switch model UMT8, up to 3 more HubPacs can be added for a full 32 user by 32 server configuration. Follow Steps 1, step 2, and step 3 above for each additional HubPac to be added. Power ON each of the Paragon Matrix Switches.
5.
CHAPTER 2: INSTALLATION
Perform Channel Configuration: Paragon recognizes a HubPac as an extension of a CIM, rather than as a device. As a result, each server connected to the HubPac is configured as a directly connected server would be. 1. On the Selection Menu (by channel ID number) each green line indicates an active channel (CIM/computer). Highlight the CIM/server to be selected by using the <!> and <"> or the <Page Up> and <Page Down> keys, then press <Enter>. Normal computer access indicates successful connection. If necessary, adjust the computers video quality by keying on <+> or <> while in Hot Key mode. Enter a meaningful name for each server (channel).
39
2. 3.
a. Press <F5> for the Administration Menu and select the Channel Configuration submenu. b. On the Channel Configuration Menu, press the <!> or <"> keys to highlight the Name field c. d. e. f.
4. for channel ID where CIM/computer was just installed. Press <Enter> - the highlight will turn blue. Edit Name and press <Enter> when finished - the highlight will turn green as you begin to type. Press <S> to save the new name. Press <F2> to return to the Selection Menu and verify that the new name appears on the Selection Menu in green.
40
CIMPac
The Paragon CIMPac, part number CIMPAC8-RK, expands user access capability to a maximum of 32 users.
Installing a CIMPac These Basic Installation instructions will assist you in creating two Paragon model UMT8 Matrix Switching configurations with eight users (UST1s) each.
Ca t 5 Port
Ca t 5 Port
Ca t 5 Port
Ca t 5 Port
DB25F
RJ45
Server
CCPnn
Cat 5 Port
Cat 5e Cable
UMT8
ES C
FUNC
EN T
ESC
FUNC
EN T
Cat 5e Cable
UST1
(1-8)
(1-8)
(Users 1-8)
(Users 9-16)
CHAPTER 2: INSTALLATION
41
Important: Prior to installation all Paragon Matrix Switch units and CIMPac units must be powered OFF. Computers and User Stations (UST1s) to be connected can be powered ON.
Create a Paragon Switch model UMT8 configuration with 8 users (UST1s): 1. Attach server(s) to CIMPac.
a.
Connect one end of a CCPnn cable to server, attaching the male HD15 video leg and the male 6-pin mini-DIN keyboard and mouse legs to appropriate video, keyboard, and mouse ports on server. b. Connect the other end of the CCPnn cable to the CIMPac, attaching the male DB25 end of the cable to female DB25 port 1 on the CIMPac. c. Power ON server. d. Repeat above steps to connect the remaining servers, connecting the CCPnn cable to the CIMPac at the DB25 2, 3, 4, 5, 6, 7, and 8 port for each consecutive server (2 through 8) added.
Note: Up to 8 servers can be connected to one CIMPac. Each 3-port cluster on the CIMPac represents one DB25 server connection with two associated Cat 5 CIMPac user ports. When each CIMPac user port in a cluster is attached to a separate Paragon UMT8 Matrix Switch, 16 users (2 CIMPac user ports x 8 users per UMT8 Switch) can have access to each server. 2. Connect the CIMPac to each Paragon UMT8 Switch by repeating all of the following steps for each 3-port cluster on the CIMPac:
Connect one end of a Category 5e UTP cable to the RJ45 Cat 5 Port immediately to the right of DB25 port X. b. Connect the other end of the cable to channel port # X on the back of UMT8 Switch number 1. c. Connect one end of a Category 5e UTP cable to the second RJ45 Cat 5 Port to the right of DB25 port X. d. Connect the other end of the cable to channel port # X on the back of UMT8 Switch number 2.
Note: There are 8 three port clusters on the CIMPac. For each cluster, the number under the DB25 port represents the cluster number. In the instructions above, X represents the cluster number 1 through 8. 3. 4. Connect power cord to back of CIMPac and power ON CIMPac. A CIMPac represents 8 servers and utilizes 8 channels on each UMT8 Switch. Because there are 32 channels available on each UMT8 Switch, up to 3 more CIMPacs can be added for a full 16 user by 32 server configuration. Repeat Step 1 and Step 2 above for each additional CIMPac to be added. Power ON each of the Paragon Matrix Switches.
a.
5.
42
2. 3.
a. Press <F5> for Administration Menu and select the Channel Configuration submenu. b. On the Channel Configuration Menu, press the <!> or <"> keys to highlight the Name c. d. e. f.
4. field for channel ID where CIM/computer was just installed. Press <Enter> - the highlighted area turns light blue. Edit the server name - highlight turns green as you begin to type - and press <Enter> when finished. Press <S> to save the new name. Press <F2> to return to the Selection Menu and verify that the new name appears on the Selection Menu in green.
CHAPTER 2: INSTALLATION
43
DESCRIPTION: 19 Rack Mount Bracket for Paragon Matrix Switch (1U) [for serial numbers that begin with CP] 19 Rack Mount Brackets for UST1 (1U)
RUST-1U
Each of these rack mount brackets can be mounted as either a forward mount or a reverse mount. Forward mount offers access to the front panel of the unit. Reverse mount offers access to the back panel ports of the unit, where cables are connected.
44
Forward Mount Installation
1. 3.
5. 1.
4.
2.
3.
U M T8
4.
1.
5. 1.
3. 4. 2.
UST1
3. 4.
Figure 31 Forward Mount of Paragon User Station (UST1) Switch Rack p/n RUST-1U
Forward Mount Installation: 1. 2. Secure cable support bar to the rear of each side bracket, opposite from the rack mount tabs. Slide Paragon Matrix Switch or User Station (UST1) between the two side brackets, at the front end near the rack mount tabs. The front of the Paragon Matrix Switch or User Station (UST1) should be flush with the front of the side brackets at the rack mount tabs. Secure the Paragon Matrix Switch or User Station (UST1) to side rack mount brackets with three screws on each side. Secure the entire assembly to the rack at rack mount tabs. Drape cables over the cable support bar.
3. 4. 5.
CHAPTER 2: INSTALLATION
Reverse Mount Installation
45
3. 1. 4.
2.
UMT8
3.
1. 5. 4.
3.
2.
UST1
1. 4. 1. 4.
3.
5.
Reverse Mount Installation: 1. 2. Secure cable support bar to the front of each side bracket near the rack mount tabs. Slide the Paragon Matrix Switch or User Station (UST1) between the two side brackets at the rear end, opposite the rack mount tabs. The front of the Paragon Matrix Switch or User Station (UST1) should be flush with the back of the side brackets. Secure the Paragon Matrix Switch or User Station (UST1) to the side rack mount brackets with three screws on each side. Secure the entire assembly to the rack at the rack mount tabs. Drape cables over the cable support bar.
3. 4. 5.
46
47
The name of the Paragon Switch is Device ID. The User Port number is the number of the Paragon Switch User Port (1 through 8) to which this user station is connected. Note: If the user station monitor displays message No Connection to Paragon, then the user station (UST1) is not connected properly to the Paragon switch unit, the Paragon switch unit is not functioning properly, or the Paragon switch is powered off. Check the Paragon switch LCD for proper operational display. Check Category 5e UTP cable to ensure it is secured properly into connectors. Try to recycle AC power on user station (UST1) to ensure it is properly powered.
1.
Enter a user name assigned by the System Administrator and press <Enter>. If user names have not been assigned, the default names are user01 through user07 for users; admin for the administrator (user names are not case sensitive). If a password is necessary, prompting will occur. Type the password and press <Enter>. The default password for user admin is raritan, typed in lowercase (passwords are case sensitive). Please refer to Changing Password within User Profile Menu on page 53 for more details.
2.
48
3. 4.
Selecting a Computer
Immediately following user login, Paragons OSUI displays the Selection Menu. Users who are already logged in should press <F2> while viewing Paragons OSUI to bring up the Selection Menu. Activate the OSUI by rapidly hitting the default Hot Key activator (the <Scroll Lock> key) twice.
The Selection Menu lists devices sorted either by channel ID number or alphabetically by device or computer name. Press <F12> to toggle these views. Default sorting is by channel ID number but will reflect the last sorting method used unless the system is re-initialized. Selection Menu Fields: The Selection Menu displays up to eight channels per page. No lists the number of the channel being scanned Ch. ID indicates physical channel to which each device or computer is connected. Name lists connected device or computer name. Scn (visible when menu is sorted by Ch ID) displays each channels specific scan rate in seconds.
Selection Menu
UMT8 Switch HWII 1/4 No Ch. ID
-----------------
--------------------------------------------------
1 2 3 4 5 6 7 8
01 02 03 04 05 06 07 08 ! NT4.0 Mail Wins95.Bob Wins98.Jack MX4-Wing.2 NT4.0-Fax MC2-16.Reg1 UMT8 Switch-Wing.4 .. Scrolling Messages Banner.. | Scan | Skip |
03 03 03 03 -03 ---
ScrlLock
NCSL
49
Page Ch. ID 07 05 02
1/4
--------------------------------
ScrlLock
Note: The <F10> key toggles between showing and not showing all channels on user OSUI menu . Pressing <F10> will operate only if the Selection Menu is sorted by Channel ID or if the System Administrator has set the System Configuration Menu option for Display All Computers to Yes. When all channels are visible, the channels scan rate is followed by a red S, indicating a group security conflict and making that computer non-accessible to the user.
1.
Press the <!> and <"> or <Page Up> and <Page Down> keys to highlight a channel for a device or computer and press <Enter> to select. When the Selection Menu is sorted by Channel ID number: User can press desired computers key number (1-8), listed in the left-hand column under No (Number), and press <Enter> to quickly jump to that channel. When Selection Menu is sorted alphabetically by Name: User can type the first character(s) of the desired device name to jump to the device name that most closely matches the characters typed, and press <Enter>. Note: A small red triangle on the left of a channel name indicates to which channel user is currently connected.
a.
If channel represents a computer, the user automatically goes to normal computer operation and leaves OSUI. b. If channel represents a connected MasterConsole device (Two-Tier Configuration), an additional OSUI Selection Menu for that device is displayed. c. To return to the base Paragon Selection Menu from any other level of Selection Menu, press the <Home> key. 2. Channel switching can be repeated by returning to the OSUI Selection Menu, or by pressing the Previous Channel key twice rapidly to return to the previously selected channel without seeing the OSUI.
50
Red
Yellow
Purple
White
51
Selecting another computers video to view when in Public View Mode will display a viewing message. This message remains on the screen as long as anothers video is being viewed and cannot be removed. Press the <Esc> key to return to Selection Menu.
P-VIEW
WIN95.BOB
Figure 37 PublicView Only Message
If another user views your computers video in Public View Mode, a message on your screen displays the viewing users name on your monitor. The message will disappear after 3 seconds.
P-VIEW
ACTIVE JAYSON
Figure 38 PublicView Sign On
When the user stops viewing your video - by selecting another channel to view or by logging out of the system - another message alerts you.
P-VIEW
OFF - JAYSON
Figure 39 PublicView Sign Off
52
User Customization
The User Profile Menu displays Paragon configuration and allows for setting or changing preferred operating parameters. Press <F4> while viewing the OSUI to bring up the User Profile Menu.
Activate the OSUI by rapidly hitting the default Hot Key activator (the <Scroll Lock> key) twice.
User
Connected: User: Susan
Profile
UMT8 Switch HWII User Port: 1
Admin: No Group: 45 Scan Mode: Global Global Scan Rate: 03 Seconds ID Display: On 03 Seconds Green Mode: Off 05 Minutes Hotkey: Scroll Lock Display Position: Menu ID Previous Channel Key: NumLck Help: Single Line LocalPC: Off .. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
User Profile Menu Fields: Connected field displays name and Channel ID number of selected device or computer, if user is currently connected to a channel. User field displays user name entered at login. User Port field displays Paragon switch user port to which user is connected. Admin field displays users administrator privileges, if any. Group field displays users group ID(s). 1. 2. 3. 4. Press the <!> and <"> or <Page Up> and <Page Down> keys to highlight a channel for a device or computer and press <Enter> to select. Please refer to the section User Profile Menu Options that follows for instructions on interpreting and editing the menu components. When editing is complete, press <Enter> - the highlight will turn yellow. Press <S> to save changes, or <Esc> to cancel changes.
53
User Profile Menu Options: 1. Scan Mode: Use the <!> and <"> or <$> and <#> keys to toggle between Global and Individual. Global Scan Mode scans each channel for the same amount of time, indicated by the Global Scan Rate. Individual Scan Mode scans each channel for the specified time as shown in Selection Menu. Default setting is Global. (Setting the channels individual scan rate is an administrator function). 2. 3. Global Scan Rate: Type a number from 01 to 24, or use <!> and <"> keys to change the rate number. Default setting is 03 seconds. ID Display: The ID Display is a small window that shows computer name and Channel ID number when switching or scanning between channels. Default setting is On/03 seconds. The two fields of control are: On/Off: Use the <!> and <"> or <$> and <#> keys to toggle between On and Off. Time: Type a number from 01 to 24 or use the <!> and <"> keys to change the number. When a time beyond 24 is chosen, a dash will be displayed, indicating the ID window will be shown all the time. Green Mode (PowerSave Mode): Blanks screen if user console is idle for a pre-specified amount of time. Default setting is Off/05 minutes. The two fields of control are: On/Off: Use the <!> and <"> or <$> and <#> keys to toggle between On and Off. Time: Type a number from 01 to 99 or use the <!> and <"> keys to change the number.
4.
5.
Hot Key: Pressing the selected Hot Key twice rapidly activates Paragons On-Screen User Interface (OSUI). Use the <!> and <"> or <$> and <#> keys to select <Scroll Lock>, <Caps Lock>, or <Num Lock>. Default setting is <Scroll Lock>. Display Position: Set the positioning of the On-Screen Menu and ID Display Window using the <!>, <">, <$> and <#> keys to physically position the selected window. Note: The Hot Key and the Previous Channel Key cannot be the same key (see item 5, above, and item 7, below).
6.
7.
Previous Channel Key: Pressing the selected Previous Channel key twice rapidly enables user to go back to previously selected device without going through the OSUI, provided that device is still accessible to user. Use the <!>, <">, <$>, or <#> keys to select <Scroll Lock>, <Caps Lock>, <Num Lock>, or <None>. Default setting is <Num Lock >.
54
8.
9.
55
View the Help Menu View the Selection Menu for a list of channels, group IDs, or scan rates; or to select a channel View the User Profile Menu to view and change user-specific operating parameters View the Administration Menu (for users with administrator privileges) Toggle On/Off AutoScan (for users with administrator privileges) Toggle On/Off AutoSkip (for users with administrator privileges) View Information Menu, which displays firmware and hardware version numbers, number of accessible KVM switches, and total number of accessible channels (PCs) Logout of Paragon; logs user out and displays the login screen Disconnects user from active channel without logging out when any OSUI is displayed Toggle menu to Display all Channels On/Off. Operational if Selection Menu is sorted by Channel ID and if Display All Computers is set to Yes
Toggle selection menu to sort by Name or by Channel ID Exit the OSUI; returns user to selection menu or login screen when no channel is selected
Note: If a user does not have administrator privileges, then functions <F5>, <F6>, and <F7> are displayed in red, indicating these functions are is not available to user. If the System Administrator has configured the system by setting Display All Computers to No, then <F10> will be displayed in red, indicating this function is not available to user.
56
A
ESC
B
FUNC
H
ENT
E
Figure 42 Paragon Switch Front Panel Buttons
Front Panel Components and Functions: 1. 2. 3. 4. 5. [ESC] button (A) is used for canceling displayed function and returning system to normal state. [FUNC] button (B) is used to select various functions. LCD (C) shows status of system and indicates functions that can be selected by pressing front panel control buttons. ["], [#], [$], and [!] buttons (D), (E), (F), and (G) are used for selecting or setting various options, depending on function being performed. [ENT] button (H) is used for confirming and executing selected function.
Start-Up Display: When Paragon switch is powered on, it performs a start-up test. It checks each channel and user port to ensure proper operation.
57
For a Paragon switch model UMT8, UMT8 Switch is the default name of the Matrix Switching Unit (this name may be changed through the System Configuration Menu). /1 is the UMT8 Switchs banked expansion unit ID. In this example, it is the main unit. All expansion units will have the same device name as the main unit, but will have different unit ID numbers. Note: Banking exemplifies Raritans dedication to future development. Banking Technology, a potentially improved KVM configuration design that conceivably banks or links Matrix Switching Units directly to each other, is currently nonfunctional. As a result, all banked expansion unit IDs will be represented by /1. 2. Line 2: User port status message: A/N User (1, 2, 3 ) None User port status displays a scrolling status of all user ports, one user port per second. The Users active channel, 1 through 256, is displayed after the user port number.
Raritan Computer Paragon: UMT8 Switch HWII/1 Ready A User (1, 2, 3 8) None
A=Active User # 1-8
OR
Raritan Computer Paragon: UMT8 Switch HWII/1 Ready N User (1, 2, 3, 8) None
N=Non-Active User # 1-8
Figure 43 LCD Normal Display
Power Up Option: If you hold down the [FUNC] button on the front panel of the Paragon Switch during Power Up, the Paragon Switch will clear its database and reset to factory defaults. Confirm functions by pressing the [ENT] button on the front panel.
58
Function Selection Screen: Several administrative functions can be performed on the Function Selection Screen on the Paragon switchs front panel.
Set LCD Contrast Display Ver./SN Test User UST1 Test Chan. UKVM Set Bank ID Re-Configure Reset UMT8 Switch
Figure 45 LCD Functions
Selecting a Function: Press the [FUNC] button on the front panel of the Paragon Switch to enter Function Selection mode and use the [$] and [#] buttons to scroll through the Function List. Press the [ENT] button on the front panel to select displayed function and use the instructions below for each specified function. Press the [ESC] button on the front panel at any time to return to Normal Display.
1.
Set LCD Contrast: Modifies contrast level of front panel LCD Display. Press the [$] or [#] button to increase or decrease contrast, and press the [ESC] button to return to normal display.
Note: LCD contrast can also be adjusted by holding the ["] button and pressing the [$] or [#] button at any time.
59
Display Ver./SN (Firmware Version and Serial Number): Displays current version of firmware and units serial number.
3.
Test User UST1 (User Station): Used by administrator to check if user stations (UST1s) are functioning properly. Press the [$] or [#] button to change user port number. Display will read OK, None, or Failed. Press [ESC] to return to normal display. If a failed condition is detected, make sure Category 5e UTP cable is installed properly and secured, or try using another UST1 to see if UST1 under test has become defective.
4.
Test Channel UKVM (CIM UKVM): Used by administrator to check if Computer Interface Module (CIM) is functioning properly. Press the [$] or [#] button to change channel number. Display will read OK, None, or Failed. Press [ESC] to return to normal display. If a failed condition is detected, make sure Category 5e UTP cable is installed properly and secured, or try using another CIM (UKVM) to see if CIM under test has become defective.
5.
Set Bank ID: Press the [$] or [#] button to ensure that Bank ID is set at 1. Press [ESC] to return to normal display.
60
6.
Re-Configure: Paragon will automatically configure the system as computers or devices are added or removed. However, the system administrator can use this function to scan and reconfigure the system manually. When complete, it will return to normal display.
7.
Reset UMT8 Switch (Paragon Unit Switch): Enables restart of Paragon switch unit as if units power had been physically turned off and back on again. However, the Paragon switch will not perform start-up test unless ENT button is held down during restart. With Paragon switch firmware 2B1 and User Station (UST1) firmware 2K10 or higher, either a power reset or a factory function reset can be performed from the front panel of the Paragon switch using shortcut button combinations.
Power Reset: Hold the [$] and [#] buttons on the front panel of the Paragon switch simultaneously for approximately three seconds. When the front panel stops scrolling, release the buttons. Factory Function Reset: Hold the [$] and [#] buttons on the front panel of the Paragon switch simultaneously while pressing the [FUNC] button. When the front panel stops scrolling, release the [$] and [#] buttons, wait an additional three seconds, then release the [FUNC] button.
61
62
CIM models capable of accepting a UST1 Direct Mode connection include: UKVMC UKVMP UKVMPD UKVMP2 USKVMC USKVMP USKVMPD USKVMPA UUSBPD
Setting a UST1 to Direct Mode: 1. 2. 3. 4. 5. 6. 7. 8. Power OFF the UST1. Connect desired CIM directly to the UST1 via Category 5e UTP cable. At the user console connected to the UST1, simultaneously hold down the <Ctrl> and <Alt> keys. Continue to hold the <Ctrl> and <Alt> keys and power ON UST1. Continue to hold the <Ctrl> and <Alt> keys. There will be two beeps. At the second beep, a message on the user console monitor will appear: DIRECT Mode: CIM connected. Release the <Ctrl> and <Alt> keys. The DIRECT Mode: CIM connected message will disappear after 10 seconds. The UST1 is now set in Direct Mode.
Note: If the Category 5e UTP cable is disconnected from either the CIM or the UST1 in the Direct Mode connection for a time period greater than three to four seconds, Direct Mode will be cancelled. To re-establish Direct Mode on the UST1, follow the steps above. Returning a UST1 to Normal Paragon Mode: 1. 2. 3. 4. 5. Power OFF UST1. Disconnect the Category 5e UTP cable from the CIM. Connect the Category 5e UTP cable from the UST1 to a Paragon switch. Connect the Paragon switch to the CIM via Category 5e UTP cable. Power ON UST1.
63
Administration
The Administration Menu1 is used for setting security classes, maintaining user names and privileges, and managing the system configuration, which enables the administrator to control user access to Paragon and all connected devices. 1. 2. Login to the system as admin (or your user name if you have administrator privileges). When the Selection Menu appears, press <F5> to display the Administration Menu, which lists submenu options. Note: The default password for the login admin is raritan (all lowercase).
Administration Menu
---1 2 3 4 5 Choose Admin Function ------------------------------------------------------System Configuration User Configuration Channel Configuration User Station Profile Refresh Configurations .. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
3.
Use the <!> and <"> keys or the numbers 1 through 5 to highlight the desired submenu, and press <Enter> to select it.
Administrative User IDs that have the group ID 00 have complete access to all submenus. Other administrative users have limited access in that they cannot select the top two submenus.
64
System Configuration
The System Configuration Menu is used for setting global parameters. 1. 2. 3. 4. Press the <!> and <"> or <Page Up> and <Page Down> keys to highlight a channel for a device or computer and press <Enter> to select. Please refer to the following section System Configuration Menu Options for instructions on interpreting and editing the menu components. When editing is complete, press <Enter> - the highlight will turn yellow. Press <S> to save changes, or <Esc> to cancel changes.
System Configuration
-------------------------------------------------------UMT8 Switch HWII No 05 Device ID:
Minutes
Operation Mode: Private P-View Admin Silent: No PC Share Timeout: 01 Sec Login Blank: Off 05 Minutes Allow Blank Password: No Default Login Name Blank: Yes .. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
System Configuration Menu Options: 1. Device ID: Type desired name of device. This gives device a unique and meaningful name, which is important with multiple Paragon units. The default name for a Paragon switch model UMT8 is UMT8 Switch HWII. Display All Computers: By setting this option, the system administrator can allow or prevent users to view all devices on the OSUI, whether or not the user has the security privileges to access them. Default setting is No. Logoff Time Out: Amount of time in minutes before an inactive user is logged out of the Paragon system. Default setting is Off/05 minutes. The two fields of control are: On/Off: Use <!> and <"> keys to toggle On and Off. Time: Type a number from 01 to 99, or use <!> and <"> keys to change the number.
2.
3.
65
Private: A computer can be accessed exclusively by one user at a time. Public View: While one user is accessing a computer, another user can select and view that users video. Status messages appear on users monitors when the Public View mode is being exercised. PC Share: A computer can be selected and accessed by more than one user, but only one user can be in control at any one time. If the user in control is idle for duration specified in the PC Share Timeout field, another user can take control of the PC.
5.
View Admin Silent: When Public View Mode is exercised, the user in control of a computer is notified when someone else views the users video. However, when P-View Admin Silent is set to Yes, System Administrators can view other users videos without prompting a notification message. Use the <!> and <"> keys to toggle Yes or No. Default setting is No.
P-VIEW
P-VIEW
6.
PC Share Timeout: If the Operation Mode is set to PC Share, and more than one user has selected a computer, the first user to operate the console (keyboard or mouse) will have control of the computer. However, another user can gain control of the computer after it has been idle for a duration exceeding the Timeout limit. Default setting is 01 seconds. Login Blank: Blanks the Login screen to protect the monitor after user console is idle for a specified amount of time in minutes. When this screen is blanked, press any key to bring back the Login screen. Default setting is Off/05 minutes. The two fields of control are: On/Off: Use the <!> and <"> keys to toggle On or Off. Time: Type a number from 01 to 99 or use the <!> and <"> keys to change the number.
7.
8.
Allow Blank Password: This field controls whether a user may specify a blank password. Use the <!> and <"> keys to toggle Yes or No. Default setting is No. Note: If this field is set to No, a user may not set a blank password. A newly created user has no password by default, unless the user or the administrator sets one.
9.
Default Login Name Blank: This field controls whether the default login name appears in the user name field of the Login Menu. Use the <!> and <"> keys to toggle Yes or No. Default setting is Yes (login name will not appear).
66
User Configuration
The User Configuration Menu enables an administrator to add, delete, or edit user names and security rights, and also displays the current connection status for each user. 1. 2. 3. 4. Press the <!> and <"> or <Page Up> and <Page Down> keys to highlight a channel for a device or computer and press <Enter> to select. Please refer to the following section User Configuration Menu Options for instructions on interpreting and editing the menu components. When editing is complete, press <Enter> - the highlight will turn yellow. Press <S> to save changes, or <Esc> to cancel changes.
USER CONFIGURATION
User: Name --------ADMIN User01 User02 User03 User04 User05 User06 User07 ADMIN Adm Group ----------Yes 00 --No 00 --No 00 --No 00 --No 00 --No 00 --No 00 --No 00 --Page: -------------------
1/1
User Configuration Menu Options: 1. 2. User: Login user name. Name: Displays and edits system user names (not case sensitive). Type up to 8 characters to change a name.
Important: The preset user name admin cannot be changed. 3. 4. Group: Displays group IDs of user. Please refer to Paragon Security: Group ID Settings on page 81 for more information. Adm: Indicates whether user has administrator privileges. Use the <!> and <"> keys to toggle Yes or No. Default setting is No.
67
5.
Connection: The Connection column shows status of each user and displays the channel to which any active user is currently connected.
Adding or Deleting Users: To Add a User: Press the <Insert> key, and when the new default user name is visible, change the default name to the desired user name. The maximum number of users is 127. To Delete a User: Move highlight bar to any user line, and press the <Delete> key. The highlighted user will be removed from system. Login As A New User: Press <L> while viewing the User Configuration Menu. The User ID will appear on the login menu, prompting login.
USER CONFIGURATION
User: John Page: 1/1 Name Connection ------------------------------------------------------------------ADMIN None Jayson Fax-Server Usera None Userb None Userc None Susan WinsNT-east John None .. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
Figure 58 Connection Information In User Configuration Menu (Far Right of User Configuration Menu)
68
Channel Configuration
The Channel Configuration Menu enables an administrator to edit or initialize a CIM. An Administrator can change device names, individual computer scan rates, device type, and group IDs associated with each computer or device. When Channel Configuration changes are saved, Paragon updates each CIM as necessary. 1. 2. 3. 4. Press the <!> and <"> or <Page Up> and <Page Down> keys to highlight a channel for a device or computer and press <Enter> to select. Please refer to the following section Channel Configuration Menu Options for instructions on interpreting and editing the menu components. When editing is complete, press <Enter> - the highlight will turn yellow. Press <S> to save changes, or <Esc> to cancel changes.
CHANNEL CONFIGURATION
3/4 UMT8 Switch HWII Scn Page: Ch ID Name ---------- ----------------------------------------------1 03 2 NT4.0 Mail 03 3 Wins95.Bob 03 4 Wins98.Jack 03 5 MX4-Wing.2 -6 NT4.0-Fax 03 7 MC2-16.Reg1 -8 UMT8 Switch-Wing.4 -.. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
Channel Configuration Menu Options: 1. 2. 3. 4. Ch. ID: Channel ID number. Name: Displays and enables editing of device name. Device names are case sensitive and may contain up to 12 characters. Scn: Displays devices individual scan rate. Type a number from 01 to 24, or use the <!> and <"> keys to change the number. Default setting is 03 seconds. Device: Displays type of connected device. Use the <!> and <"> keys to edit a device type. If a type other than the computer type (CPU) is selected, it is assumed that a Raritan KVM switch has been connected to the channel according to the installation procedure for Multi-Tier Installation. A default device name is created when a KVM switch is selected. It is highly recommended that you change the name to something meaningful, as the name will be programmed to the CIM associated with the device.
69
5. 6.
Ch. ID: Channel ID number. Group: Displays security groups that device is associated with. Please refer to Paragon Security: Group ID Settings on page 81 for more information.
Note: Many Raritan KVM Switches are Paragon ReadyTM, and as a result require no configuration when connected as a tiered device to Paragon, including second or third tier switch units.
CHANNEL CONFIGURATION
3/4 UMT8 Switch HWII Page: Ch ID Group ---------- -------------------------------------------------1 -- -- -- -- -- -- -- -2 00 - - - - - - - - - - - - - 3 -- -- -- -- -- -- -- -4 -- -- -- -- -- -- -- -5 -- -- -- -- -- -- -- -6 00 - - - - - - - - - - - - - 7 - - - - - - 45 - - 62 - - - 8 - - 23 - - - - - - - - - - - .. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
Figure 60 Ch ID and Group Information in Channel Configuration Menu (Far Right of Channel Configuration Menu)
Important: If you have more than one path connecting to MX4, all channels should have the same name to ensure that Paragon will configure the tier channels properly.
70
Video delay -- switching: 00 Sec .. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
Keyboard Type Setting The Paragon OSUI supports English, French, or German keyboard mapping. To select a keyboard type: 1. 2. Press the <!> and <"> keys and select the desired keyboard type. Press <Enter> to register the change, then <S> to save, or press <Esc> to exit without saving. Note: When changing keyboard type, the change is applied only to the User Station where this selection has been made. Video Delay -- Switching Use this field to adjust the amount of delay time (in seconds) when switching from channel to channel. The delay can be programmed to last from 0 to 30 seconds; during the delay, the screen will be blank. To adjust Video delay: 1. 2. Press the <!> and <"> keys to increase or decrease the number of seconds, or use the number keys to type in the amount of time desired for video delay, to a maximum of 30 seconds. Press <Enter> to register the change, then <S> to save, or press <Esc> to exit without saving.
71
Refresh Configurations
Select item 5 - Refresh Configurations on the Administration Menu to refresh the database of all user stations from the Paragon switch database.
Administration Menu
---1 2 3 4 5 Choose Admin Function ------------------------------------------------------System Configuration User Configuration Channel Configuration User Station Profile Refresh Configurations .. Scrolling Messages Banner.. ScrlLock | Scan | Skip | NCSL
72
73
Hardware Requirements
System Administrators can install and run the Overview program from any PC loaded with Internet Explorer.
Downloading Overview
Download Overview from Raritans Web Site to a Floppy Diskette: 1. Open Internet Explorer and go to Raritans Web Site, http://www.raritan.com. 2. 3. 4. 5. 6. Click the menu bar link to Tech Support. Select Firmware Upgrades. When the new page opens, click on the hyperlink Firmware Upgrades. Locate the execution file for Paragon Overview and click on the corresponding hyperlink. Save the file to a floppy diskette.
Connecting a PC to UST1
1. 2. Using a standard DB9 serial cable, plug DB9(F) into one of the Com ports on the PC. Plug the other end of the DB9 cable, DB9(M), into the Admin port of any UST1 connected to a base Paragon Switch.
PS/2
SUN
PS/2
VGA
AC IN (0.5A/0.25A)
Admin.
Mouse
K/M
Keyboard
Monitor
Cat5 Port
Important: All users should be logged out of the Paragon System when configuration data is being changed.
74
Activate PC Communication and Login: 1. 2. 3. Click on the Activate Port button on the Communication Control Panel. Select the COM port to which the DB9 serial cable is installed (default is COM1). The program initiates communication with UST1.
75
Connect to UST1 and Download Configuration: This step downloads UST1s configuration file for offline editing at the PC. 1. 2. The Serial Number from the UST1 unit will be retrieved and displayed in an information window. Click on the OK button to continue. A copy of the configuration file will be downloaded from the UST1 to the PC. Maintenance functions can now be performed. A status window displaying the message Loading data from Paragon will display during download, and user station keyboard and mouse operation will be temporarily suspended.
76
Note: Overview provides the ability to edit only existing user profiles. User profiles may not be added or deleted through Overview. You must add or delete user profiles at the UST1.
77
Note: Overview provides the ability to edit only existing device profiles. Device profiles may not be added or deleted through Overview. You must add or delete device profiles at the UST1.
78
79
Troubleshooting
SYMPTOM: Program begins. After clicking on the Activate Port button, a message appears UMT8 Switch device is not responding. POSSIBLE CAUSE: Make sure DB9 cable is plugged in to PC DB9 serial port properly. Make sure a proper Comm port number is selected. Recycle UST1 AC power. This will not affect computers connected to the Paragon Matrix Switch. Check serial port on PC; it may be defective. Check for loose cable connection between PC and UST1. Make sure serial communication between PC and UST1 is not broken. !Press <Ctrl>+<Alt>+<Del> to bring up the Close Program window. !Select Paragon System Administration Utilities entry. If status is Not responding click on the End task button to terminate the program. !Restart the program from the Start Menu. An alternative status indicates the program is waiting for a slow PC to perform. Convert a DB25 to DB9 using a standard adapter
After a period of trouble free software operation, clicking on the Send to Paragon button causes the Windows status bar to remain on the screen.
80
81
USER GROUPS: Available Group IDs for Assignment Maximum Number of Group IDs Which Can Be Assigned 00 99 5
COMPUTER GROUPS: 00 99 8
Users and computers communicate according to the following Group ID access rules: GROUP ID FOR USERS: 00 For IDs 01 through 09: 0X through 0X For example: 05 For IDs 10 through 99: X0 through X9 For example: 98 00, 09 and 98 00, 0X, and exact same computer ID# as the users ID# 00, 05; and 50, 51, 52, 53, 54, 55, 56, 57, 58, and 59 00, 0X; and X0, X1, X2, X3, X4, X5, X6, X7, X8, and X9 CAN ACCESS COMPUTERS WITH GROUP IDS: 00 through 99 (all computers)
82
GROUP ID FOR COMPUTERS: 00 For IDs 01 through 09: 0X through 0X For example: 08 For IDs 10 through 99: X0 through X9 For example: 12
00, 0X; and X0, X1, X2, X3, X4, X5, X6, X7, X8, and X9
00, 08; and 80,81, 82, 83, 84, 85, 86, 87, 88, and 89
00, 0X, and exact same user ID# as the computers ID#
Recommendations
Systems Requiring High Security: Raritan Computer recommends assigning IDs of 10 through 99 to computers requiring high protection. This will make them less accessible than computers with IDs of 00 or 01 through 09. Main System Administrator and Assistant Administrators: Although any user may be assigned Administrative Privileges, we recommend the user ID 00 for the Main System Administrator, and user IDs 01 through 09 for Assistant Administrators. These IDs provide a broader scope of access.
83
Important: Z-series chains should be added one at a time. The message banner on the screen should read that the DB has been completely updated before an administrator adds a new Z-chain. Installing a Z-CIM for Personal Computer Access: 1. 2. Set up Paragon following the Basic Installation instructions starting on page 12. Choose the UST1 and user console that will access both a local Personal Computer and the Paragon matrix.
84
3. 4.
a.
Connect the Category 5e UTP cable from the chosen UST1 to the UTP OUT port on the ZCIM. b. Connect another Category 5e UTP cable to the UTP IN port on the Z-CIM c. Connect the other end of this UTP cable to the reserved user port on the Paragon Switch. 5. Connect the Personal Computer to the Z-CIM. UKVMSPD: a. Attach the CIM to the computer via its 15-pin male video port, connecting it to the 15-pin female video port on the computer. b. Connect keyboard and mouse cable legs from the UKVMSPD to appropriate 6-pin mini-DIN mouse and keyboard ports on computer. UKVMSC: a. Connect DB25 male end of CCP06 cable to DB25 female port on UKVMSC Z-CIM. b. Connect the other end of the CCP06 cable to appropriate 6-pin mini-DIN mouse and keyboard ports, and the HD15 video port on the Personal Computer. 6. Power ON Personal Computer.
Activate Local PC Mode on UST1: 1. 2. 3. 4. 5. Login from the chosen User Station, which will have access to both a local Personal Computer and the Paragon Switch. Press <F4> to display the User Profile Menu. Use the <!> or <"> keys to go to the Local PC field and press <Enter> - the yellow highlight will turn green. Use the <!> or <"> keys to select On and press <Enter> - the highlight will turn yellow. Press <S> to save the change and return to the User Profile Menu, or press <Esc> to return to the User Profile Menu without saving this change.
Operating Local Personal Computer Access: 1. 2. Press the <Home> key twice to access the local personal computer quickly while viewing any OSUI menu. You will automatically be switched to the local or home PC. To return to Paragon switching, bring up Paragons OSUI by rapidly pressing the hot key activator twice. Then press <F2> to bring up the Selection Menu, which shows all servers and devices connected to Paragon. Note: If you changed the Hot Key activator, remember to use your new Hot Key assignation to activate the OSUI.
CHAPTER 9: SPECIFICATIONS
85
CHAPTER 9: SPECIFICATIONS
ITEM
PARAGON SWITCH
DIMENSIONS (WXDXH)
17.2 (W) X 10.4 (D) X 1.75 (H) 437MM (W) X 265MM (D) X 44 MM (H)
WEIGHT
7.9LBS. (3.59KG)
POWER
100V/240V 47/63HZ, 0.6A
OPERATIN G TEMP.
0-40 C
32-104 F 0-40 C 32-104 F 0-40 C 32-104 F 0-40 C 32-104 F 0-40 C 32-104 F 0-40 C
UMT2161 UMT242 17.2 (W) X 10.4 (D) X 1.75 (H) 437MM (W) X 265MM (D) X 44 MM (H) 17.2 (W) X 10.4 (D) X 1.75 (H) 437MM (W) X 265MM (D) X 44 MM (H) 17.2 (W) X 10.4 (D) X 1.75 (H) 437MM (W) X 265MM (D) X 44 MM (H) 17.25 (W) X 10.75 (D) X 3.5 (H) 438MM (W) X 273MM (D) X 89 MM (H) 11.4 (W) X 10.1 (D) X 1.75 (H) 290MM (W) X 255MM (D) X 44 MM (H) 8.35LBS. (3.8KG) 8.45LBS. (3.82KG) 8.15LBS. (3.7KG) 12.0LBS. (5.44KG) 100V/240V 47/63HZ, 0.6A 100V/240V 47/63HZ, 0.6A 100V/240V 47/63HZ, 0.6A 100V/240V 47/63HZ, 0.6A 100V/240V 50/60HZ, 0.5A
UMT442
UMT8
UMT1664
4.3LBS. (1.9KG.)
32-104 F
4.3 (W) X 3.6 (D) X 1.0 (H) 108MM (W) X 91MM (D) X 23MM (H)
0.7LBS. (0.3KG.)
6VDC
0-40 C 32-104 F
2.0 (W) X 3.125 (D) X 1.125 (H) 51MM (W) X 79MM (D) X 29MM (H)
0-40 C 32-104 F
2.44 (W) X 3.5 (D) X 1.0 (H) 62MM (W) X 89MM (D) X 27MM (H) 0.4LBS. (0.16KG.) 1.68 (W) X 3.5 (D) X 0.75 (H) 43MM (W) X 89MM (D) X 19MM (H) 0.4LBS. (0.16KG.)
DIRECTCONNECT TECHNOLOGY
86
ITEM
CIMS FOR SUN
4.3 (W) X 3.6 (D) X 1.0 (H) 108MM (W) X 91MM (D) X 23MM (H)
0.7LBS. (0.3KG.)
6VDC
0-40 C 32-104 F
2.0 (W) X 3.125 (D) X 1.125 (H) 51MM (W) X 79MM (D) X 29MM (H)
0-40 C 32-104 F
1.68 (W) X 3.5 (D) X 0.75 (H) 43MM (W) X 89MM (D) X 19MM (H) 0.4LBS. (0.16KG.)
NONE
0-40 C 32-104 F
USKVMPA CONNECT ONE SUN COMPUTER - WITH 13W3/COMPOSITE SYNC VIDEO USKVMP + ADAPTER
2.0 (W) X 3.125 (D) X 1.125 (H) 51MM (W) X 79MM (D) X 29MM (H) (X 2 UNITS USKVMP + ADAPTER) 0.7LBS. (0.3KG.)
NONE
0-40 C 32-104 F
CIMS FOR ASCII DEVICES 4.3 (W) X 3.6 (D) X 1.0 (H) 108MM (W) X 91MM (D) X 23MM (H) 0.7LBS. (0.3KG.) 6VDC 0-40 C 32-104 F
4.3 (W) X 3.6 (D) X 1.0 (H) 108MM (W) X 91MM (D) X 23MM (H)
0.7LBS. (0.3KG.)
6VDC
0-40 C 32-104 F
2.0 (W) X 3.125 (D) X 1.125 (H) 51MM (W) X 79MM (D) X 29MM (H)
0-40 C 32-104 F
1.68 (W) X 3.5 (D) X 0.75 (H) 43MM (W) X 89MM (D) X 19MM (H) 0.4LBS. (0.16KG.)
NONE
0-40 C 32-104 F
CHAPTER 9: SPECIFICATIONS
87
USKVMC
USKVMP
USKVMPD
USKVMPA
AUATC
88
CIM MODEL: AUPUSBC
UUSBP
UUSBPD
CHAPTER 9: SPECIFICATIONS
89
Pin-out specifications for RJ45 connectors to Category 5e UTP cable: Paragon supports only T568A or T568B pin-outs
T568A
Mod Plug Positions White/Green
T568B
Mod Plug Positions White/Orange
1 2 3 4
Cat 5e Cable
1 2 3 4 5 6 7 8
R J 4 5 C O N N E C T O R
R J 4 5 C O N N E C T O R
Cat 5e Cable
5 6 7 8
Important: Maximum distance from user console to computer is 1,000 feet. When using certified cable, users can transmit video signals at distances up to 1,000 feet at 1024x768 @75Hz; and up to 600 feet at 1600x1200 @75Hz.
90
CIM Cable Kits (For UKVMC): Additional cables available for desired distances longer than those enabled by the standard length cables are provided with each CIM unit ordered. Universal Cable Kits for connecting computer to CIM: PART NO.: LENGTH: CONNECTORS:
6.5 (2 M) 13 (4 M) 20 (6 M) 30 (9 M)
DB25(M) TO HD15(M), 2x mini-DIN6(M) DB25(M) TO HD15(M), 2x mini-DIN6(M) DB25(M) TO HD15(M), 2x mini-DIN6(M) DB25(M) TO HD15(M), 2x mini-DIN6(M)
Universal Cable Kit adapters for AT-style keyboard and serial mouse: (1) DIN 6F to DIN 5M and (1) DIN 6F to DB9F can be ordered for any CCPdd cable (part number: APSAT). Accessories: PART: RPAR1U DESCRIPTION: 19 Rack Mount Bracket (for UMT8 Switch) - 1U [for S/N beginning with CM] 19 Rack Mount Bracket (for UMT2161, UMT8, UMT442, UMT242 Switch) 1U [for S/N beginning with CP] 19 Rack Mount Bracket (for UMT1664 Switch) - 2U 19 Rack Mount Bracket (for UST1) - 1U Sync on green converter for HP9000 or SGI with HD15 video Sync on green converter for SGI with 13W3 video Sync on green converter for RS/6000 with 13W3 video
RUMT-1U
91
Monitor video display for some connected computers is distorted. Keyboard non-functional, even though there is no keyboard error at power up. Cannot input to any computer. Repeated Keyboard ERROR at computer power-up.
Keyboard suddenly locks-up when a particular computer is selected, but works normally when other computers are selected.
Loose mouse cable from computer to CIM Loose Category 5e UTP cable If error occurs only with new computers being added to system, contact Raritan Technical Support for assistance mouse emulation firmware may need to be upgraded for compatibility with newer computers.
92
SYMPTOM:
Mouse suddenly locks up when a particular computer is selected, but works normally when other computers are selected. On-Screen User Interface (OSUI) non-functional. Video is fuzzy or out of focus.
Multi-Tier Installation
In a multi-tier configuration, the order of powering ON is critical to proper function. Last tier switches must be powered ON before the intermediate level of tier Intermediate tier switches must be powered ON before the base Paragon switch can be powered ON. User Stations (UST1s) can be powered ON and OFF at any time as needed. There is a five-second ON/OFF down time in the UST1 or Paragon power cycle.
93
#1752A
Stranded
#1872A #7702
Solid
Use of non-certified cabling may result in video and data degradations that users may find unsatisfactory. When using certified cable, users can transmit video signals at distances up to 1,000 feet at 1024x768 @75Hz; and up to 600 feet at 1600x1200 @75Hz.
Please note that Raritan does not have any marketing relationship with Belden, nor does Raritan receive any financial incentive for recommending Belden products.
Yes, however, you may not get the same performance as you would with Raritan certified Category 5e UTP or Category 6 UTP cables. Standard Category 5 UTP cable may not have the necessary characteristics for transmitting high-quality video over long distances.
No, because standard Ethernet cable does not have the necessary bandwidth characteristics for transmitting highquality video over long distances.
94
QUESTION:
Yes. Currently only one Category 6 UTP cable product is Raritan certified for use with Raritan products. Raritan continues to test new Category 6 UTP cabling products as they are released to the market.
Cable products that are not specifically certified by Raritan may cause your video to look blurry; in particular if the video signal is of high-resolution, or if the video signal must be transmitted over long distances. Furthermore, LCD monitors can become unusable
95
Because the intended application of UTP cabling is the transmission of digital data, cable specifications are optimized for that application. However, because video data is by its very nature analog, Raritans exclusive technology which enables such high-bandwidth video information to be transmitted over relatively thinly-shielded Category 5 UTP and Category 6 UTP cables requires even stricter tolerances for certain cable properties. One particular UTP cable characteristic has a large impact on how well your Raritan system performs: delay skew. UTP cabling consists of four twisted pairs of wire, each carrying one set of data. In order to minimize cross-interference between the pairs, each pair must be twisted at slightly different rates (twists/foot). Over long lengths of cable, however, slight differences in twist rates results in measurably different rates of data transmission among each twisted pair. The arrival time delta is called delay skew. How does this affect your Raritan solution? Raritan products send red, green, and blue video information each over a different twisted pair; if that information does not arrive at the same time, observed video will be blurry. Raritans unique algorithms correct for this behavior, but physical limitations create upper limits to the success of any algorithm. The TIA/EIA specification for delay skew tolerance is 45 nanoseconds for Category 5 UTP and Category 5e UTP cable. However, in analog video applications, a delay skew longer than 15 nanoseconds usually results in inadequate video performance at high resolutions (XGA and higher). Raritan-certified cable products happen to surpass the acceptable tolerances of the TIA/EIAs specification for delay skew, and hence are best suited for connecting Raritan components.
96
QUESTION: Are there special pin out requirements that I must use?
97
Administration Menu
AutoScan
Channel
CIM Class Security Code Computer Name (Channel Name) Configuration Device
98
TERM: Global Scan Rate
Green Mode
ID Display
Inactive Channel
Key Number
LCD Display
Local Console
One-Tier Configuration
OSUI Password
99
Public View
Reserved Channels
S Model
Scan
Scan Mode
Scan Rate
Time interval in seconds that a channels computer is to remain displayed on monitor when AutoScan is activated. See also Global Scan Rate and Channel Specific (Individual) Scan Rate.
Security Code
Number set assigned to each user and computer to establish useraccess rights. See also Class Security Code, and Group Security Code.
Selection Menu
Set-Password Screen
100
TERM: Sort
Start-Up Display
Displayed on LCD when the Paragon Matrix Switch is powered on system checks for the status of computers and user connections. After this start-up test, system goes to normal display.
System Configuration
For allowing and disallowing blank passwords, turning Time Out on and off, changing Time Out interval, turning Login Screen on and off, and changing Login interval.
Time Out
Length of time that a user port can remain idle that is, since the previous keyboard/mouse or front panel operation before connected console is automatically logged out. User must enter an authorized user name to re-establish access after Time Out.
Two-Tier Configuration
A mix of devices computers, other units and MasterConsole units - are connected to base Paragon Matrix Switch units.
User Configuration
Used by administrator for adding, deleting, and changing user names, security codes, and administrator privileges.
User Console
Keyboard, monitor, and mouse plugged into a user port on UST1 back panel.
User Name
User Port
The RJ45 connector by which a user station (UST1) is connected to a Paragon Matrix Switch.
101
UST1 X Model
Acronym for User Station MasterConsole II models MasterConsole X-4, MasterConsole X-8, and MasterConsole X-16.
102
APPENDICES
103
APPENDICES
Appendix A: Paragon Update Firmware Upgrade
The Paragon Update Utility is a Win32-based program that facilitates the transfer of firmware to Paragon units the Matrix Switching Unit and the User Station (UST1). The Paragon Update Utility and the latest versions of firmware can be downloaded from Raritans web site:
http://www.raritan.com.
Important: Before performing a firmware upgrade, be certain to read the release notes that are included with the firmware distribution on Raritans website.
Note: All Paragon components and connected servers can remain powered ON during a firmware upgrade. Paragons modular redundant design ensures that these devices will not be affected during the update process.
104
Paragon Configuration Backup: Paragon Update is designed to execute the firmware uploading process without disturbing Paragon configuration data files. However, as an added precaution, many users prefer to backup these configuration files, which contain user profile and server name information. 1. Download the Paragon Overview program from Raritans Web site.
a. b. c. d. e. f.
2. 3. 4.
Open Internet Explorer and go to Raritans Web Site: http://www.raritan.com. Click on the menu bar link to Tech Support. Select Firmware Downloads. When the new page opens, click on the hyperlink Firmware Downloads. Locate the execution file for the Paragon Overview download and click on the corresponding hyperlink. Save the file to a floppy diskette.
Log into Paragon on any active Paragon User Station (p/n UST1) and press <F12> to display the Selection Menu by Name. When the Paragon User Station displays the Selection Menu by Name, connect one end of a straight-through serial cable to the port labeled Admin on the back of the User Station (DB9F). Connect the other end of the cable to the serial port of any computer with Paragon Overview installed.
Important: To ensure reliable communication, use as short a serial cable as possible. Do not use a serial cable longer than 50 feet in length. Be sure to use a straight-through serial cable, and not a null modem cable. 5. 6. 7. 8. 9. On the attached computer, double-click on the Paragon Overview icon to launch Overview. Select the correct serial port (COM1 through COM4), and click on the Activate Port button to the right on the Overview program window to initiate communication with Paragon. After the Paragon database is downloaded, a prompt will appear for an administrators User Name and Password. Enter the administrator User Name and Password. Select Save from the File menu, and save the Paragon Configuration database to the hard disk. Select Exit from the File menu to exit the Paragon Overview program.
Paragon Firmware Update Instructions: 1. Download the Paragon Firmware distribution file, ParagonFirmware.zip from Raritans Web site.
a. b. c. d. e. f.
2.
Open Internet Explorer and go to Raritans Web Site: http://www.raritan.com. Click the menu bar link to Tech Support. Select Firmware Downloads. When the new page opens, click on the hyperlink Firmware Downloads. Locate the appropriate version of the Paragon Firmware.zip download and click on the corresponding hyperlink. Save the file to a floppy diskette.
Unzip the downloaded file, and read the release notes for any additional or updated instructions.
APPENDICES
105
Important: To ensure reliable communication, use as short a serial cable as possible. Do not use a serial cable longer than 50 feet in length. Be sure to use a straight-through serial cable, and not a null modem cable. 3. 4. 5. Launch the Paragon Update on the attached computer by double clicking the icon. Select the correct serial port (COM1 through COM4), and click on the Activate Port button on the right on the Overview program window to initiate communication with Paragon. Click on the Load Hex File button and select the User Station firmware contained in the Paragon Firmware distribution file, e.g., UST1-####, where #### is a hexadecimal version number. The upper button in the Upgrade Information section of the Paragon Update window will read Paragon User Station. Click on the Test Hex File button to ensure file integrity. Click on the Check Device Information button to confirm successful communication with the Paragon User Station and to confirm that the firmware upgrade is applicable. Click on the Paragon User Station button to begin uploading the firmware. Note: During the firmware uploading process, the User Station and the computer must be powered ON, and the serial cable must remain firmly connected. 9. Click on the Disable Port button, then exit Paragon Update.
6. 7. 8.
10. After successfully receiving the new firmware, the User Station will reset automatically and a beep will signal the reset. Note: If automatic reset of the User Station does not occur, then recycling power to the User Station will manually reset the unit. No loss of data will occur by resetting power to the user station. 11. Repeat steps 3 through 12 for each User Station to be updated, clicking on the Disable Port button and exiting the Paragon Update each time you have updated a User Station.
106
5. 6. 7.
10. Repeat steps 2 through 9 for each Paragon Matrix Switching unit to be updated, clicking on the Disable Port button and exiting Paragon Update each time you have updated a Matrix Switching unit.
APPENDICES
107
PCs
108
1. 2. 3. 4.
Install an IBM x330 Rack of Servers as a Tier to Paragon: Set up Paragon following Basic Installation instructions starting on page 12, but reserve one channel port for each rack of IBM x330 servers to be connected. Connect a Category 5e UTP cable to the reserved channel port on the back of the Paragon Switch. Connect the other end of the category 5e UTP cable to the RJ45 port on a Raritan CIM UKVMP-x330 or UKVMC-x330. Attach the CIM to IBM Break Out Cable from the x330 rack. UKVMP-x330: a. Connect keyboard, monitor, and mouse cable legs attached to CIM to appropriate 15-pin female video port and 6-pin mini-DIN mouse and keyboard ports on IBM Break Out Cable. UKVMC-x330: a. Connect DB25 male end of CCPnn cable to DB25 female port on UKVMC-x330. b. Connect the other end of the CCPnn cable to appropriate 6-pin mini-DIN mouse and keyboard ports, and HD15 video port on IBM Break Out Cable.
Set the IBM x330 Rack as a Second Tier Device: 1. 2. 3. 4. 5. 6. 7. 8. 9. From a User Station, login as admin, or use your user name if you have administrator privileges, and enter your password. Press the <F5> key to go the Administration Menu, then select Channel Configuration submenu. Use the <!> and <"> or the <Page Up> and <Page Down> keys to select the channel to which the IBM x330 rack is connected. Press the <Tab> key to advance to the Device field - the highlighted area will be yellow. Press the <Enter> key - the highlighted area turns green. Use the <!> and <"> keys to change device type to IBM x330, then press the <Enter> key - the highlighted area turns yellow. Hold the <Shift> key and press the <Tab> key to go back to the Name column. Press the <Enter> key and edit the default name. Press the <S> key to save the new configuration.
Save and Verify Changes: 1. Press <F2> to go Selection Menu to validate that second-tier IBM x330 rack is properly configured. Select and switch to one of the IBM x330 channels. Normal computer access and operation indicates a successful connection. Press <F5> to go to Administration Menu. Select Channel Configuration submenu. Select the IBM x330 channel. Press <G> to bring up a Channel Configuration menu of the IBM x330. Edit names for each IBM x330 server in the rack. Press <S> to save the new configuration.
2.
3.
255-30-5004