Xilica XP Series Manual
Xilica XP Series Manual
Xilica XP Series Manual
User Manual
12. USE ONLY WITH CART, STAND, TRIPOD, BRACKET, OR TABLE SPECIFIED BY THE
MANUFACTURER, OR SOLD WITH THE APPARATUS. WHEN A CART IS USED, USE
CAUTION WHEN MOVING THE CART/APPARATUS TO AVOID INJURY FROM TIP-OVER.
Do not place this unit on an unstable cart, stand, tripod, bracket, or table. The unit may
fall, causing serious injury to someone, and serious damage to the appliance. A unit and
cart combination should be moved with care. Quick stops, excessive force, and uneven
surfaces may cause the product and cart combination to overturn.
13. UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR
LONG PERIODS OF TIME.
For added protection for this unit during a lightning storm, or when it is left unattended
and unused for long periods of time, unplug it from the wall outlet and disconnect the
antenna or cable system. This will prevent damage to the unit due to lightning and power
line surges.
15. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPARATUS TO RAIN OR MOISTURE.
Shipped contents:
- XP Unit
- User Manual
- XConsole Software
- Power Cord
1
For XP-2040M / 3060M / 4080M / 8080M only.
1 3 5 6 7
2 4 8
When the <<Menu or Menu>> key is held down, the Mute Buttons
selects the corresponding channel for the LCD menu display and is
acknowledged by a green LED below the button. The last modified menu
will be displayed on the LCD. Multiple channels can be linked or
unlinked by pushing the desired channels. This eases programming for
same parameters across multiple channels. Multiple Inputs can be linked
together and multiple outputs can be linked together. Inputs and Outputs
are linked separately.
5. Peak Level LED – Indicates the current peak level of the Signal:
1,2,3 4 5
2
XLR connectors for XP-2040 / 3060 / 4080, Euro Connectors for XP-8080
** XILICA XP **
XP-4080 v9.00B
• The initialization process takes several seconds and during that period
the unit boots and displays the device model and firmware version.
• After the initialization process is finished the XP displays its main screen:
** XILICA XP **
P01*
• The screen shows the current program number and program name
assigned to the unit. If the program number ends with *, it means that no
program is assigned, the last data before previous power down is
recalled instead.
Channel Linking – While holding down the <<Menu or Menu>>, more than
1 channel from the same group (Input or Output group) can be selected to
link the channels together. The green LEDs below the Mute buttons are lit
for the linked channels. Any modification of the data for the selected
channel will be applied to the linked channels as well. To cancel the linking,
simply deselect the desired channel while the <<Menu or Menu>> key is
still pressed, or just press the Exit key to deselect all channels.
I1:______ Mic
LEVEL:0dB
LEVEL:
The level (or gain) ranges from 0dB to +45dB in 3dB steps. This level will
only have an affect on the input channel when Mic Input is selected from
the System Menu. Please refer to page 22 for more details.
LEVEL:
The level (or gain) ranges from -40.00dB to +15.00dB in 0.25dB steps.
I1:______ Signal
LEVEL:0.00dB
POL:
The polarity (or phase) can be normal (+) or inverted (-).
I1:______ Signal
POL:+
3
For XP-2040M / 3060M / 4080M / 8080M models only.
I1:______ Signal
DELAY:000.000ms
EQ#:
Each input channel has 8 bands of equalization. This control selects one of
the 8 available bands.
I1:______ EQ1
EQ#:1
BYPASS:
This control will un-bypass (Off) or bypass (On) the currently selected band.
I1:______ EQ1
BYPASS:Off
TYPE:
The 5 types of EQ that can be used are: parametric (PEQ), low shelf (LO-
SHF), high shelf (HI-SHF), 1st degree all-pass (AP-1), and 2nd degree all-
pass (AP-2).
I1:______ EQ1
TYPE:PEQ
FREQ:
The EQ center frequency ranges from 20Hz to 30kHz in either 1Hz steps or
1/36 octave steps. The frequency steps can be selected in the System
Menu. Please refer to page 21 for more details.
I1:______ EQ1
FREQ:1000Hz
LEVEL:
The EQ level (or gain) ranges from -30.00dB to +15.00dB in 0.25dB steps.
I1:______ EQ1
LEVEL:0.00dB
GEQ#:
The graphic equalizer has 31 bands of equalization from 20Hz to 20kHz.
This control selects one of the 31 available bands. The frequency
corresponding to each band is also shown.
I1:______ GEQ1
GEQ#:1 f=20
LEVEL:
The GEQ level (or gain) ranges from -30.00dB to +15.00dB in 0.25dB steps.
I1:______ GEQ1
LEVEL:0.00dB
BYPASS:
This control will un-bypass (Off) or bypass (On) the entire GEQ for this
channel.
I1:______ GEQ1
BYPASS:Off
TYPL:
The 3 available filter types for the low frequency crossover point (high pass)
are: Butterworth, Linkwitz Riley or Bessel.
O1:______ XOver
TYPL:Off
FRQL:
The filter cut-off frequency for the low frequency crossover point (high pass)
ranges from 20 to 30kHz in either 1Hz steps or 1/36 octave steps. The
frequency steps can be selected in the System Menu. Please refer to
page 21 for more details.
O1:______ XOver
FRQL:1000Hz
SLPL:
The filter slope for low frequency crossover point (high pass) ranges from 6
to 48dB/octave. The available slopes are 12, 24, 36 or 48 dB/octave.
O1:______ XOver
SLPL:24dB
TYPH:
The 3 available filter types for the high frequency crossover point (low pass)
are: Butterworth, Linkwitz Riley or Bessel.
O1:______ XOver
TYPH:Off
O1:______ XOver
FRQH:1000Hz
SLPH:
The filter slope for high frequency crossover point (low pass) ranges from 6
to 48dB/octave. If the selected filter type is Linkwitz Riley, the available
slopes are 12, 24, 36 or 48 dB/octave.
O1:______ XOver
SLPH:24dB
THRESH:
The compressor threshold ranges from -20 to +20dBu in 0.5dB steps.
O1:______ Comp
THRESH:+20.0dB
ATTACK:
The compressor attack time ranges from 0.3 to 1ms in 0.1ms steps, then
ranges from 1 to 100ms in 1ms steps.
O1:______ Comp
ATTACK:10ms
RELEASE:
The compressor release time can be set at 2X, 4X, 8X, 16X or 32X the
attack time.
O1:______ Comp
RELEASE:8XAtck
RATIO:
The compressor ratio is the slope in which the signal is compressed. It
ranges from 1:1 to 1:40.
O1:______ Comp
RATIO: 1:1
NAME:
A 6 characters name can be assigned to each channel.
I1:______ Name
NAME:______
THRESH:
The limiter threshold ranges from -20 to +20dBu in 0.5dB steps.
O1:______ Limit
THRESH:+20.0dB
ATTACK:
The limiter attack time ranges from 0.3 to 1ms in 0.1ms steps, then ranges
from 1 to 100ms in 1ms steps.
O1:______ Limit
ATTACK:10ms
RELEASE:
The limiter release time can be set at 2X, 4X, 8X, 16X or 32X the attack
time.
O1:______ Limit
RELEASE:8XAtck
IN1-8:
This sets the input channel source for the current output channel. It can be
used to mix the input source (in dB) or disable it (Off). If more than one
input sources are enabled, they will be added together as the source for the
current output channel.4
4
Number of Inputs is dependent on the model.
The System Menus allow the user to control and change parameters that
are related to the system behavior and general operation. It can be
accessed by pressing the Sys key in the main menu (when no Input/Output
or System Menu is activated). All System Menus require pressing the Enter
key to confirm and save the settings.
P:
This control selects which program to recall from the non-volatile memory.
The program name is displayed to the right of the program no.
SYSTEM Recall
P:1 ____________
P:
This control selects which preset location in the non-volatile memory to be
saved.
SYSTEM Store
P:1
SYSTEM Store
NAM:____________
IN1-8:
The user can choose between Line input or Mic input. For Mic input, the
input will receive a 30dB gain. Each input channel can be selected
individually.
SYSTEM Mic/L
IN1:Line
The optional microphone preamp also comes with 48Volt Phantom Power,
which can also be enabled or disabled per channel in this menu.
SYSTEM Phantm
IN1:On
Copy Channels from the source to the target. When the Source and Targets
are both Inputs and Outputs, all audio parameters will be copied. When one
of the Source or the Target is an input while the other is an output, only the
Level, Polarity, Delay, EQ, Crossover, and Channel Name are copied.
SOURCE:
This is the channel to be copied from.
5
For XP-2040M / 3060M / 4080M / 8080M only, applies to Phantom Power as well.
TARGET:
This is the channel to be copied to.
SYSTEM Copy
TARGET:In2
FREQ MODE:
This changes the frequency control mode for EQ and crossover filters. It
can be 36 steps/octave or All Frequencies (1 Hz resolution).
SYSTEM Generl
FREQ MODE:All
DELAY UNIT:
This sets the time unit for input and output delay to ms, ft, or m.
SYSTEM Generl
DELAY UNIT:ms
Eth-IP:
A unique IP address should be assigned to each unit in the network.
SYSTEM Eth-IP
:255.255.255.254
Eth-GW:
The gateway address of the network. Usually, this should be the IP address
of your router/switch/hub address.
SYSTEM Eth-GW
:255.255.255.255
Eth-SM:
The sets the subnet mask used by your network.
SYSTEM Eth-SM
:255.255.255.255
NOTE: User must power cycle the unit for this settings to take effect.
DEVICE ID:
This control assigns a device ID from 1 to 16 to the unit. This ID is only
useful when a network of more than 1 unit is used in conjunction with 1 or
more XPanels.
SYSTEM Comm
DEVICE ID:1
SYSTEM Comm
BAUD RATE:115200
NETWORK ID:
This control assigns a network ID from 0 to 60000 to the unit. This ID is
used for future network expansion only, please leave it at 0.
SYSTEM Comm
NETWORK ID:0
PASSWORD:
The password is 4 characters in length. The factory default of a new unit
does not require a password.
The device can be protected for unauthorized parameter and /or system
abuse. The securtity settings can be controlled and stored in the device with
the XConsole GUI only.
When the correct password is entered in the device all the locks are
disabled. After reientering the password or powercycling the device, the
locks are automatically enabled again.
SYSTEM Secure
PASSWORD:____
CURRENT:
This resets all the current parameters back to factory default settings only,
while stored presets and system settings stay untouched.
SYSTEM Reset
CURRENT:Yes
SYSTEM ISO
THRESHOLD:102
SYSTEM ISO
BYPASS:On
SYSTEM Info
NAM:____________
SYSTEM Info
FIRMWARE:v9.00
And the third and last screen displays the security code.
When no password is set the factory default code is 11110000.
SYSTEM Info
CODE:11110000
Menu Field
Parameters <<Menu <<Cursor> Min Max Steps Units
>> >
Mic Level Mic LEVEL 0 +45 3 dB
Level Signal LEVEL -40 +15 0.25 dB
Polarity Signal POL +/-
10us
Delay Signal DELAY 0 62400 1
steps
EQ Number EQ EQ# 1 8 1
EQ Bypass EQ BYPASS Off /On
EQ Type EQ TYPE PEQ / Lo-Shf / Hi-Shf / AP-1 / AP-2
EQ Level EQ LEVEL -30 +15 0.25 dB
EQ Frequency EQ FREQ 20 30,000 1 Hz
EQ Bandwidth EQ BW 0.02 3.61 0.01 Octave
GEQ Number GEQ GEQ# 1 31 1
GEQ Level GEQ LEVEL -30 +15 0.25 dB
GEQ Bypass GEQ BYPASS Off / On
Off / Butterworth / Linkwitz-Riley /
XOver Low Type XOver FTRL
Bessel
XOver Low Frequency XOver FRQL 20 30,000 1 Hz
XOver Low Slope XOver SLPL 6 48 6 dB/octave
Off / Butterworth / Linkwitz-Riley /
XOver High Type XOver FTRH
Bessel
XOver High Frequency XOver FRQH 20 30,000 1 Hz
XOver High Slope XOver SLPH 6 48 6 dB/octave
Compressor Threshold Comp THRESH -20 +20 0.5 dBu
Compressor Attack Time Comp ATTACK 0.3 100 0.1 / 1 ms
Compressor Release Time Comp RELEASE 2 / 4 / 8 / 16 / 32X Attack time
Compressor Ratio Comp RATIO 1:1 to 1:40
Limiter Threshold Limit THRESH -20 +20 0.5 dBu
Limiter Attack Time Limit ATTACK 0.3 100 0.1/1 ms
Limiter Release Time Limit RELEASE 2 / 4 / 8 / 16 / 32X Attack time
1, 2, 3, 4, 5,
Source Source Off +15 0.25 dB
6, 7, 8
Channel Name Name NAME 6 characters
6
The latest version of XConsole and USB driver are available at www.xilica.com.
Audio Performance
Frequency Response: +/- 0.1dB (20 to 30kHz)
Dynamic Range: 115dB typ (unweighted)
CMMR: > 60dB (50 to 10kHz)
Crosstalk: < -100dB
Distortion: 0.002% (1kHz @+4dBu)
Connectors
Analog Inputs: 3-pin Female XLR7
Analog Outputs: 3-pin Male XLR8
RS-232: Female DB-9
USB: Type B
Power: Standard IEC Socket
General
Power: 90-240 VAC (50-60Hz)
7
3-pin Euro Block for XP-8080 model
8
3-pin Euro Block for XP-8080 model
System Parameters
No. of Presets: 30
Program Names: 12 character length
Delay Units: ms, ft, m
Frequency Modes: 36 steps/oct, 1Hz resolution
For factory service, please call or email for a Return Authorization (R/A)
number before shipping. If the product is shipped, the following information
must be included in the package:
1. Owner’s complete name, daytime phone number, return street address
and return authorization number.
2. The serial number of the product being returned and a copy of the retail
sales receipt, if possible.
3. A complete description of the problem(s) experienced, including a brief
description of how the equipment is being used and other equipments
involved.
www.xilica.com