(SIGNERS) SCS User Manual - 02. How To Use SCS& Gram Viewer (VET)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 50

User Manual-02

How to Use
SUPiA CR SYSTEM / Gram Viewer(Optional Product)

This User Manual may be revised for the improvement of the product, without prior notification.
Images in this User Manual may differ from the actual product.

SUPiA CR SYSTEM 1/50 Signers Co., Ltd Rev_08 (2020.07.21.)


Table of Contents

1. How to use ································································································································································ 3


1.0 Frequently used functions ································································································································ 3
1.1 Installation of SUPiA gram ······························································································································ 3
1.2 System start-up procedure ······························································································································ 3
1.3 Operating of SUPiA CR SCANNER and CASSETTE ···················································································· 4
1.4 Operating of SUPiA gram ································································································································ 5
1.4.1 Calibration ······················································································································································ 5
1.4.2 Worklist Screen ············································································································································· 5
1.4.3 Acquire Screen ··········································································································································· 16
1.4.4 Setup Screen ··············································································································································· 23
1.5 System shut-down procedure ······················································································································· 29
1.6 Cleaning after use ············································································································································ 29
1.7 Cautions for USB connection ························································································································ 30
2. How to use gram Viewer ·································································································································· 31
2.1 gram viewer S/W ············································································································································· 31
2.1.1 Log in of gram viewer ······························································································································ 31
2.1.2 Open images ··············································································································································· 36
2.1.3 Tools ······························································································································································ 38
2.1.4 Setting · ························································································································································ 39
2.1.5 Export ···························································································································································· 41
2.1.6 Print ······························································································································································· 45

SUPiA CR SYSTEM 2/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

1. How to use

1.0 Frequently used functions


1. Turn on/off main switch of SUPiA CR SCANNER
2. Insert SUPiA CR CASSETTE into the Tray (cassette slot) of SUPiA CR SCANNER.
3. Checking the status display LED light condition
4. <Start scan> function
5. <New patient> function
6. Image rotation function
7. Image inverting function
8. Image length measurement

1.1 Installation of SUPiA gram


1. Insert the supplied SUPiA gram CD into the PC and install it.
Installation of SUPiA gram should be performed by authorized service
engineer.
CAUTION And we do not recommend connecting to the Internet because of
problems such as hacking, virus infection, etc.

2. Double click installation file ( ). (All installation process is progressed automatically.)

3. After installation, the S/W icon ( ) is generated on the window screen.

1.2 System start-up procedure


1. Make sure that the USB cable is connected between the PC and SUPiA CR SCANNER.
2. Turn on the mains switch of SUPiA CR SCANNER.
3. Turn on the mains switch of the PC installed SUPiA gram.

4. Double click the S/W icon( ) on the PC window, than the below screen is displayed.

SUPiA CR SYSTEM 3/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

5. Initial ID: admin PW: 0000

1.3 Operating of SUPiA CR SCANNER and CASSETTE


1. Insert SUPiA CR CASSETTE exposed by X-ray equipment into the cassette slot of SUPiA CR
SCANNER. After insertion, the cassette could not be removed from SUPiA CR SCANNER until
the scanning is finished.

Please note that the direction of insertion of the cassette.


If the direction is wrong, the cassette is not inserted.
CAUTION

the cassette before booting the equipment can cause noise, so


make sure to put it in green when the equipment is booted.
CAUTION

2. Insert the cassette, then the LEDs equipped on SUPiA CR SCANNER are turned on as green.
(The green “ON” means “under scanning”.)
3. After scanning, the LEDs are flashed as green. (The green “flash” means “under erasing”.)
4. After erasing, the LEDs are turned on as green again. (The final green “ON” means “All
scanning process is finished.”)
5. Remove the cassette from the scanner.

SUPiA CR SYSTEM 4/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

1.4 Operating of SUPiA gram


1.4.1 Calibration
-Before use, calibration must be performed. You can calibrate by cassette size (when size is
different), by bar code (when size is same). If you have two cassettes of the same size, it
means that you can calibrate only one or both. The calibration related interface can be
checked on page 47.

1.4.2 Worklist Screen

- In this screen, inspection standby animal list, inspection paused patient list and inspection
finished patient list are displayed.

- Register a new animal by click <New animal>.


- Screen panel: Panel to search worklist using various function buttons.

Display the list of all animals waiting to be examined or completed

Enter the currently selected animal's ACQUIRE screen

Displays the photographer. You can change the photographer in the preferences,
Admin
and the changed photographer will be reflected.

- Device Status : Below the SW logo, it displays the connection status of the device, such as
whether the device is connected, inserted cassette problem or not.

SUPiA CR SYSTEM 5/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

- Device Connection & Status bar: The notification bar displays a lot of information in real
time so that the user can check the status of the equipment at a glance without any action,
and it is configured to move to the environment setting screen and minimize or close the
window

This window displays the shooting resolution. The resolution can be


differentiated into HD, SD.

Button to eject cassette of CR equipment


If the device is not connected or the cassette has already been removed,
the button is disabled. (If the button is enabled it will appear white.)

If you click on it, you will be prompted to insert a cassette and the erase
will proceed when you insert the cassette.

Check other status: Device connection status, MWL connection status,


server connection status, printer connection status, remaining storage space
(displayed as %). When connected normally, it appears white.

It is a button to go to the configuration screen(setting), a minimize button,


and an exit button.

- Query : Displays the last time the patient information was retrieved.

- Search date button : Button to specify the date range to which patient information to be
displayed belongs.

SUPiA CR SYSTEM 6/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

- Specify the search start date and the search completion date as shown in the screen above.

If you press button, only the patient information of the specified date is displayed.

If you press , the previous condition is restored.

- Quick search : Window to search for animals by ID, name, gender, etc.

- Display search panel : A panel designed to determine whether to display animals waiting to
be examined and animals who have been checked.

You can select the desired attributes to be displayed in the list, change the order of the
attributes, and change the font size. If the worklist is linked, the animal information is
displayed by a query without any additional procedure, and the animal registered by clicking
the new animal registration icon is also displayed. Double click to enter ACQUIRE screen.

- Thumbnail : Displays an image of a animal that has already been studied.


The image of the animal is displayed as shown below. Information about the number of
images, image and shooting area is displayed. If animal information is selected from the
work list and the image is moved, the image is moved to the selected patient.

If there is no recorded image and only the order is taken, the image disappears and only
the remaining information is displayed. In addition, whether the check was completed,
whether it was sent, rejected, etc., is displayed at the top right.

- Add-on Panel : A panel that performs additional functions such as new animal registration,
query barcode, etc.

SUPiA CR SYSTEM 7/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

This icon is used to register emergency patients and patients who are not
connected to MWL. When you click it, you will enter the study
composition screen.
The query icon. If MWL is linked, this icon will bring up patient
information.
Bar code registration button. If you want to use a barcode scanner to scan
a barcode, the color changes to orange and you can scan in any order.
Click again to cancel.

The export button is disabled when the patient’s statue is ‘Waiting’ as


shown above. Click the patient to export the image and then turn on

PACS. This activates the button in the upper right corner.

SUPiA CR SYSTEM 8/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

Patient information edit button. When you click (2) will enter.

Patient information deletion button. When you click (3) pop-up window will
appear, and the selected patient information will be deleted.

SUPiA CR SYSTEM 9/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

(1) Export screen

No. Name Function

1 DICOM SEND Select the displayed server list, and click to send the
selected image to the selected server.

Select the file format and image save path you want to save
2 Image storage
and click to save the image in the selected path.

Determines the layout for the image to be printed when the


3 DICOM PRINT
printer is connected.

Displays images to be exported as thumbnails. If you check

4 Thumbnail at the top right, only the checked image will be


selected, and when you click again, it will be deselected.

SUPiA CR SYSTEM 10/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

If you want to print multiple images on a single film, please refer to the above picture.
Up to four images can be output simultaneously on one film. Click on the images you want to
print and click on the layout icon.

Then you can see the interface like above.


At this time, you can change the position between images and adjust as below.

SUPiA CR SYSTEM 11/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

(2) Screen for animal information edit

You can edit the above information such as the Vet Name, Forma, etc. of the selected animal.

It will be modified when clicked and canceled when clicked . However, it is not
possible to modify the ID of patient information retrieved through MWL linkage.

SUPiA CR SYSTEM 12/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

(3) Screen for animal information delete

The above pop-up window will be displayed. If you click , the selected animal will be

deleted. If you click , the pop-up window disappears.

2. Study composition screen


It is used when animal information or inspection information can not be used by using work
list, or when it is necessary for operator to manually create and use patient information and
inspection information due to emergency situation.

- Enter animal information : Window for inputting information such as animal ID, name,
date of birth, sex, veterinarian name, etc.

SUPiA CR SYSTEM 13/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

If you click the register button without entering ID, name, date of birth, and gender, a
pop-up window will pop up as shown below. The veterinarian is admin by default and can
be edited

- Registration and Acquire : This button registers the entered animal or enters the Image
screen.

Registration icons. If animal information and body part are entered and
clicked, animal information is registered on the work list screen.

Acquire icon. When you click it, you will go to the image screen.

- Study composition: You can organize inspection list by window with main body part, body
part, projection and animal body diagram.

SUPiA CR SYSTEM 14/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

- For example : If you want to configure Thorax, DV scan as shown above,


a. Select Thorax, in the Body Part.
b. Select DV, in the Projection.
c. Make sure that Thorax DV study is created in the Exam List.
When compositing the study list, all of the Main Body Part, Body Part, and Projection
must be selected before the test mode can be entered.

- Exam list : A window that lists the tests that you selected in the study composition screen

The selected study list is displayed in order. Select the check area and click below to
delete the selected study list.

SUPiA CR SYSTEM 15/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

1.4.3 Acquire Screen


It is the screen to check and correct the patient information to be shot, to edit the image of
the patient and to reprocess the image.

- Enter patient information

It is a window to display the ID, birth date, gender, etc. of animal information registered

on the worklist screen. ID and name are displayed in the window.

When you click the button, you can see the list of patients waiting to be studied. In

addition, when you click the Modify button , the following pop-up window will appear
and patient information can be modified.

SUPiA CR SYSTEM 16/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

- Thumbnail : Displays images that have already been studied.

SUPiA CR SYSTEM 17/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

In the case of pre-recorded images, the order of shooting is displayed in the upper left
corner as 1, 2, 3 ..., and the top right shows intuitively whether the image was rejected or
transmitted correctly. At the bottom, you will see a list of the tests you have taken. If it is
not before shooting, the image disappears and only the shooting sequence and inspection
list are left. When you select an image to scan and insert a cassette into the machine, the

image is implemented. Button is a button that moves up and down when the
number of images is large.

No. Name Function

This button adds the body part to be shot. A pop-up window


1
appears when you click to add a body part.

2 It is activated when the printer is connected.

When the server is connected, it is activated and transmits the


3
image taken when clicked to the server.

- Image : Displays images that have already been studied.

SUPiA CR SYSTEM 18/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

No. Name Function

It shows numerical values of Width (0 ~ 65535), Level (0 ~


65535) and Zoom (50% ~ 1,000%) of the displayed image. You
1
can adjust the number by directly entering the number where it
appears.

Displays the recorded image. Only the frame is displayed before


2 shooting. If you are scanning an image, you can preview the
image being scanned in several steps.

This is an intuitive indication of the position of the cassette, and


3
disappears during transmission and printing.

It is designed to know the size of the actual image. When you


enlarge or reduce an image, you can zoom in and out at the
4
same rate to know the size of the actual image.
It disappears during transmission and output.

- Image parameter window : Window to fine tune the parameter value of the displayed
image

SUPiA CR SYSTEM 19/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

No. Name Function

Histogram of the image. Displays the width, level, etc. of the image
1
in a graph.

2 Image processing slide bar. 1, 2, and 3 are fine-tuned.

Parameter reset button. The parameter that was adjusted when


3
clicked is initialized.

Parameter save button. The changed parameter value is saved when


4 clicked. This parameter value also applies for images in the same
area.

The color reversal button. You can use the Invert function which
5
reverses black and white.

- Edit toolbar : Tools for editing images and tools for approving images

SUPiA CR SYSTEM 20/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

1 You can cut to the size of the film or the size you want.

2 Reverses the image vertically.

3 Reverses the image horizontally.

4 Rotate the image 90 ° to the left.

5 Rotate the image 90 ° to the right.

6 Rotate the image by 1 °. You can enter the desired angle directly.

Measure function. You can use the tape measure to overlay length values on the
7
screen.
Measure function. You can use the protractor to overlay the angle value on the
8
screen.

9 You can measure the area or perimeter.

Marking can be done. When you press the button, a list of available markings
appears. You can also input the marking you want, and you can specify the size
10
and position of the marking. The marking list can be configured separately on the
setup screen.

Image reset button. When clicked, the image is initialized to the acquired state and
11
the contents of the edited image are also initialized.

Save button. The edited operation is saved in the image screen. The same
12
conditions apply when shooting the same area after storage.

Copy button. You will create one more image of the current image, and one image
13
will be added to the thumbnail.

The reject button. The selected image will not be sent to the server, and
14
thumbnails will indicate that this image was rejected in the top right corner.

Transfers the selected image to the server. It is disabled if there is no recorded


15
image or communication with the server is not possible.

This button changes the body part. When you click, a pop-up window will appear
16
where you can change the body part. If there is no recorded image, it is disabled.

SUPiA CR SYSTEM 21/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

-Special tool: If you click area icon, you can see special tools like below.

1 Area: You can get the area by taking a points. (Max 25times)

Cobb Angle: Use this to calculate the angle by clicking the spinal cord left / right
2
on the spinal cord curvature.
Laminitis measurement:
3 It is used to measure acute or chronic aseptic inflammation in the hoof of a horse
or horse.

4 VD Thorax: The ratio of the Cardiac Width to the Thorax width.

5 Hip Dysplasia: The Norberg-angle of the hip in dogs and cats.

6 Vertebral heart Score: The size of an animal's heart.

Tibial Tuberoses Advancement (TTA): Determine the appropriate tibial tuberosity


7
advancement distance.

8 Tibial Plateau Leveling Osteotomy (TPLO): The tibial plateau angle or tibial slope

SUPiA CR SYSTEM 22/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

1.4.4 Setup screen


The configuration screen consists of four boards: environment setting, DICOM, anatomical,

and calibration. You can enter the setting screen by clicking the button.

- Configuration
(1) User management
You can add, edit, or delete users. It is recommended that you do not share your ID
and password with other users.
① Add : When the button is clicked, the following pop-up window will appear.
And you can enter the ID name password and add the user.

② Modified : When the button is clicked, the following window will appear.
And user information can be modified.

SUPiA CR SYSTEM 23/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

③ Delete : The selected user is deleted.

(2) Basic setting


① Clinic name : The name of the hospital using the equipment.
② Language : You can select the language to be displayed.

③ Font : You can select the font for the displayed language.

④ Date format : You can select the format of the displayed date.

SUPiA CR SYSTEM 24/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

⑤ Separator : You can select a separator to distinguish the date format.

⑥ Days to keep images : You can set the number of days to keep the image. When it
is 0, it keeps the whole.

⑦ Show storage : Displays the remaining capacity of the total disk. At this time, it can
be displayed as ratio or capacity

⑧ Image storage LOW : Sets the minimum disk usage allowed by the program in %. In
the figure above, it is set to 80%. Therefore, when the disk usage reaches 80% of
the total disk capacity, the oldest scan information is automatically deleted.

⑨ Maximum disk usage : Sets the upper limit of the capacity of the usable disk in %.
The figure above is set to 90%. Therefore, when the disk usage reaches 90% of the
total disk capacity, the setting of the minimum disk usage is automatically deleted to
secure the capacity of the disk.

SUPiA CR SYSTEM 25/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

⑩ Image storage location : Choose where you want to save the image.

(3) Order mapping


You can map the inspection code

① Add
After entering the order code and the order description, select the part and click the
Add button, a new inspection code will be generated. If you press the Cancel button,
the pop-up window will disappear. Select a region from the mapping list and click the
Delete button to delete the region from the mapping list.
② Modified : You can modify the mapping information in the same way when you select
the mapping information and click the Modify button.
③ Delete : You can delete the mapping information by selecting the mapping
information and clicking the Delete button.
(4) Marking
The already entered marking information is displayed. You can set marking information
with the Add and Delete buttons.
(5) Usage information
Displays the number of scans and erases of the equipment and cassette, and displays
the version information of the SW.

SUPiA CR SYSTEM 26/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

- DICOM
You can make settings related to DICOM service.

(1) User management


Displays the value of the corresponding property like IP, Port Called AE Title, Alias,
Default.
(2) The icon to enter the property value.
① Echotest : Test whether worklist, storage, and print are connected. When you
select the item you want to test, it is activated. When you deselect it, it is
deactivated.
② Add / Modified : When you click the pop-up window will appear as below, you can
add / modify work list, storage, and print.

③ Delete : If you select the item you want to delete, it is activated and you can modify
the work list, storage, and print.
(3) DICOM-related automatic request time, character set, Calling AE Title, and whether to
compress.

- Anatomical

SUPiA CR SYSTEM 27/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

(1) You can modify BodyPart and Projection according to MainBodyPart. Click the Modify button
and the following window will appear.

allows you to add BodyParts and Projections and delete

BodyParts and Projections on clicks . If there is an addition, the button is

activated and the content applied at the time of click changes. When the
button is clicked, the window disappears.

(3) The Edit All button. When clicked, the following window will appear. You can change
the PM Tube value, resolution and image parameter value.

SUPiA CR SYSTEM 28/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

-Device info

(1) The resolution according to the cassette size is displayed, and if the calibration is
completed, it is marked as 'X' if it is not completed with '0'.
(2) If applicable, write down the Mammo Licensky and press the Ac

1.5 System shut-down procedure


Please keep it in the oder described below.
1. Close the window of SUPiA gram.
2. Shut-down the PC at window main menu.
3. Turn off the main switch of SUPiA CR SCANNER.

1.6 Cleaning after use


1. Clean the surface of SUPiA CR SCANNER and CASSETTE using a soft cloth.
2. Do not use any kind of liquid to clean SUPiA CR SCANNER and CASSETTE.

SUPiA CR SYSTEM 29/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

1.7 Cautions for USB connection between SUPiA CR SCANNER and PC for SUPiA gram

USB port should be used for connecting PC installed SUPiA gram.


CAUTION

SUPiA gram should be installed at PC complied by IEC/EN 60950-1.


CAUTION If not, electrical harms could be appeared to operator.

The responsible organization should identify, analyze, evaluate and


CAUTION control the risks.

Do not connect the other electrical equipment.


Do not change the network environment after installing SUPiA gram.
CAUTION Do not remove the USB cable while operating the device.
Do not update ofr upgrade the PC after installing SUPiA gram.

SUPiA CR SYSTEM 30/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

2. How to use gram viewer S/W


2.1 gram Viewer S/W
*The viewer Program is CR (SUPiA CR SYSTEM) and DR (Stellar M17) common and
compatible for both human and animal applications.
*Note that the sample images below were taken against people.
*About the installation, refer to installation manual.
Regardless of the connection or possession of the equipment, you can check the patient's image.
The software can integrate data from images obtained from its models SUPiA gram and Stellar
gram. Viewer software with this useful feature is not a default option when purchasing equipment
and should indicate to the manufacturer that it is willing to purchase it.

If you have purchased this optional Viewer S/W, please refer to the below.

2.1.1 Log in of gram viewer


To log in to the Viewer Software, you first need to add an account from the Console software.

Log in with ID:admin, PW:0000 on Console SW.

Click Setting Icon to register a new ID that will be used in gram viewer.

SUPiA CR SYSTEM 31/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

Click Add to register a new user in the Account tab and then create the ID and password.
*Please remember your password as you log in with this account as gram Viewer

If you have added an account in the console software (SUPiA gram), close the window and then run
gram viewer, and place your mouse on the Setup button located at to top left of the screen.

If you activate the Set up botton, a screen like the one above appears.
Input the IP address of the Console PC, default port: 219
(If you don’t know your Ip address, please refer to below).

SUPiA CR SYSTEM 32/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

Ø How to find my IP address

Connect to network and sharing center from the control panel and click the wifi connection button
above.

Click the ‘Details’ button.

SUPiA CR SYSTEM 33/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

Check my IP address.

Enter the IP address and press the ‘OK’ button.

SUPiA CR SYSTEM 34/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

You have to enter added account in Console Software, not ID:admin PW:0000

The ID entered when logging into gram viewer is displayed at the top of the screen.

SUPiA CR SYSTEM 35/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

2.1.2 Open images

Click 'Today' tab, you will get the calender and select the date. And click 'OK' button.

SUPiA CR SYSTEM 36/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

Double click the patient's name.

Click on the patient information to see the desired image on thumbnail.

SUPiA CR SYSTEM 37/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

If you want to open another patient’s image, click down arrow then name list appears.

2.1.3 Tools

Distance Angle Area of ROI

Arrow Square Circle

tape measure protactor to Text


to overlay overlay the
length angle value

Contrast/Bright Reset

SUPiA CR SYSTEM 38/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

2.1.4 Setting

Click the Setting button at the top right of the screen.

1) Option

You are able to change the color of Markings, Line and Text as well as the
language and font in Option tab.

SUPiA CR SYSTEM 39/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

2) DICOM

You can configure the DICOM printer in this window tab. There are more settings that character set,
Image compression type.

SUPiA CR SYSTEM 40/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

2.1.5 Export

Open the image to be exported. and then click this button.

SUPiA CR SYSTEM 41/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

Select the image you want to export by dragging.

SUPiA CR SYSTEM 42/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

1 How to save the image (CD/HDD/USB)

2 Where to save the image ( C Drive, D Drive, etc )

In what format will the iamge be exported? (DICOM format, Image format, Whether to
3
include the viewer?)

When you finish selecting the image to be exported and the addition as above and click the ‘OK’
button located at the bottom right, the above window.

Enter the path you specified to check the exported image.

Click the ‘app’ folder among the two created folders.

SUPiA CR SYSTEM 43/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

Run the ‘Viewer’ program.

You can check the number of exported images, and information including the patient name is
displayed in the upper left corner.

SUPiA CR SYSTEM 44/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

2.1.6 Print

If you want to print to a printer, press the button at the bottom left.

SUPiA CR SYSTEM 45/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

1) Printer Type
You can choose 2 types of printer to print.
Standard printer refers to a network printer with a PC connected to it, and DICOM printer is an
abbreviation for Digital imaging and Communications in Medicine, which applies a kind of standard
communication protocol that is compatible with image information between medical devices.

If you want to output DICOM printer, please press the setting icon located in the upper right
corner. After selecting DICOM tab, please enter DICOM printer information and start ping test.

SUPiA CR SYSTEM 46/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

When all information is entered correctly and the connection is complete, the following notification

pop-up appears and click the OK button .

2) Paper size
If you selected the type of printer to print, select the paper size. You can select six types, in inches.

If the actual paper size differs from the selected paper size, the DICOM printer will display
this error, so check the paper size again and print it out.

3) Zone separation

You can place more than two pictures to print, and you can adjust the position be dragging the
pictures to print.

SUPiA CR SYSTEM 47/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

4) Option
You can print out a logo or text by inserting it into the image.

-Logo

Logo image format must be image format.

-Text

You can insert letters in the image or adjust font size and only fill in the required items through the
checklist.

5) Patient Information

The patient image information to be printed is briefly displayed

SUPiA CR SYSTEM 48/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

6) Output setting

Select the information to be included in the printed image.

7) Tools

Pan Reset

Magnify Contrast/Bright

SUPiA CR SYSTEM 49/50 Signers Co., Ltd Rev_08 (2020.07.21.)


http://signers.co.kr
User manual
(SIG-SUMHE-01)

8) Thumbnail

The images for that patient appear listed. If you have a lot of images, use the scroll to check.

If the ping test is carried out normally at 1) , press the button on the bottom right after all
settings are completed to complete the output.

SUPiA CR SYSTEM 50/50 Signers Co., Ltd Rev_08 (2020.07.21.)