(SIGNERS) SCS User Manual - 02. How To Use SCS& Gram Viewer (VET)
(SIGNERS) SCS User Manual - 02. How To Use SCS& Gram Viewer (VET)
(SIGNERS) SCS User Manual - 02. How To Use SCS& Gram Viewer (VET)
How to Use
SUPiA CR SYSTEM / Gram Viewer(Optional Product)
This User Manual may be revised for the improvement of the product, without prior notification.
Images in this User Manual may differ from the actual product.
1. How to use
4. Double click the S/W icon( ) on the PC window, than the below screen is displayed.
2. Insert the cassette, then the LEDs equipped on SUPiA CR SCANNER are turned on as green.
(The green “ON” means “under scanning”.)
3. After scanning, the LEDs are flashed as green. (The green “flash” means “under erasing”.)
4. After erasing, the LEDs are turned on as green again. (The final green “ON” means “All
scanning process is finished.”)
5. Remove the cassette from the scanner.
- In this screen, inspection standby animal list, inspection paused patient list and inspection
finished patient list are displayed.
Displays the photographer. You can change the photographer in the preferences,
Admin
and the changed photographer will be reflected.
- Device Status : Below the SW logo, it displays the connection status of the device, such as
whether the device is connected, inserted cassette problem or not.
- Device Connection & Status bar: The notification bar displays a lot of information in real
time so that the user can check the status of the equipment at a glance without any action,
and it is configured to move to the environment setting screen and minimize or close the
window
If you click on it, you will be prompted to insert a cassette and the erase
will proceed when you insert the cassette.
- Query : Displays the last time the patient information was retrieved.
- Search date button : Button to specify the date range to which patient information to be
displayed belongs.
- Specify the search start date and the search completion date as shown in the screen above.
If you press button, only the patient information of the specified date is displayed.
- Quick search : Window to search for animals by ID, name, gender, etc.
- Display search panel : A panel designed to determine whether to display animals waiting to
be examined and animals who have been checked.
You can select the desired attributes to be displayed in the list, change the order of the
attributes, and change the font size. If the worklist is linked, the animal information is
displayed by a query without any additional procedure, and the animal registered by clicking
the new animal registration icon is also displayed. Double click to enter ACQUIRE screen.
If there is no recorded image and only the order is taken, the image disappears and only
the remaining information is displayed. In addition, whether the check was completed,
whether it was sent, rejected, etc., is displayed at the top right.
- Add-on Panel : A panel that performs additional functions such as new animal registration,
query barcode, etc.
This icon is used to register emergency patients and patients who are not
connected to MWL. When you click it, you will enter the study
composition screen.
The query icon. If MWL is linked, this icon will bring up patient
information.
Bar code registration button. If you want to use a barcode scanner to scan
a barcode, the color changes to orange and you can scan in any order.
Click again to cancel.
Patient information edit button. When you click (2) will enter.
Patient information deletion button. When you click (3) pop-up window will
appear, and the selected patient information will be deleted.
1 DICOM SEND Select the displayed server list, and click to send the
selected image to the selected server.
Select the file format and image save path you want to save
2 Image storage
and click to save the image in the selected path.
If you want to print multiple images on a single film, please refer to the above picture.
Up to four images can be output simultaneously on one film. Click on the images you want to
print and click on the layout icon.
You can edit the above information such as the Vet Name, Forma, etc. of the selected animal.
It will be modified when clicked and canceled when clicked . However, it is not
possible to modify the ID of patient information retrieved through MWL linkage.
The above pop-up window will be displayed. If you click , the selected animal will be
- Enter animal information : Window for inputting information such as animal ID, name,
date of birth, sex, veterinarian name, etc.
If you click the register button without entering ID, name, date of birth, and gender, a
pop-up window will pop up as shown below. The veterinarian is admin by default and can
be edited
- Registration and Acquire : This button registers the entered animal or enters the Image
screen.
Registration icons. If animal information and body part are entered and
clicked, animal information is registered on the work list screen.
Acquire icon. When you click it, you will go to the image screen.
- Study composition: You can organize inspection list by window with main body part, body
part, projection and animal body diagram.
- Exam list : A window that lists the tests that you selected in the study composition screen
The selected study list is displayed in order. Select the check area and click below to
delete the selected study list.
It is a window to display the ID, birth date, gender, etc. of animal information registered
When you click the button, you can see the list of patients waiting to be studied. In
addition, when you click the Modify button , the following pop-up window will appear
and patient information can be modified.
In the case of pre-recorded images, the order of shooting is displayed in the upper left
corner as 1, 2, 3 ..., and the top right shows intuitively whether the image was rejected or
transmitted correctly. At the bottom, you will see a list of the tests you have taken. If it is
not before shooting, the image disappears and only the shooting sequence and inspection
list are left. When you select an image to scan and insert a cassette into the machine, the
image is implemented. Button is a button that moves up and down when the
number of images is large.
- Image parameter window : Window to fine tune the parameter value of the displayed
image
Histogram of the image. Displays the width, level, etc. of the image
1
in a graph.
The color reversal button. You can use the Invert function which
5
reverses black and white.
- Edit toolbar : Tools for editing images and tools for approving images
1 You can cut to the size of the film or the size you want.
6 Rotate the image by 1 °. You can enter the desired angle directly.
Measure function. You can use the tape measure to overlay length values on the
7
screen.
Measure function. You can use the protractor to overlay the angle value on the
8
screen.
Marking can be done. When you press the button, a list of available markings
appears. You can also input the marking you want, and you can specify the size
10
and position of the marking. The marking list can be configured separately on the
setup screen.
Image reset button. When clicked, the image is initialized to the acquired state and
11
the contents of the edited image are also initialized.
Save button. The edited operation is saved in the image screen. The same
12
conditions apply when shooting the same area after storage.
Copy button. You will create one more image of the current image, and one image
13
will be added to the thumbnail.
The reject button. The selected image will not be sent to the server, and
14
thumbnails will indicate that this image was rejected in the top right corner.
This button changes the body part. When you click, a pop-up window will appear
16
where you can change the body part. If there is no recorded image, it is disabled.
-Special tool: If you click area icon, you can see special tools like below.
1 Area: You can get the area by taking a points. (Max 25times)
Cobb Angle: Use this to calculate the angle by clicking the spinal cord left / right
2
on the spinal cord curvature.
Laminitis measurement:
3 It is used to measure acute or chronic aseptic inflammation in the hoof of a horse
or horse.
8 Tibial Plateau Leveling Osteotomy (TPLO): The tibial plateau angle or tibial slope
and calibration. You can enter the setting screen by clicking the button.
- Configuration
(1) User management
You can add, edit, or delete users. It is recommended that you do not share your ID
and password with other users.
① Add : When the button is clicked, the following pop-up window will appear.
And you can enter the ID name password and add the user.
② Modified : When the button is clicked, the following window will appear.
And user information can be modified.
③ Font : You can select the font for the displayed language.
④ Date format : You can select the format of the displayed date.
⑥ Days to keep images : You can set the number of days to keep the image. When it
is 0, it keeps the whole.
⑦ Show storage : Displays the remaining capacity of the total disk. At this time, it can
be displayed as ratio or capacity
⑧ Image storage LOW : Sets the minimum disk usage allowed by the program in %. In
the figure above, it is set to 80%. Therefore, when the disk usage reaches 80% of
the total disk capacity, the oldest scan information is automatically deleted.
⑨ Maximum disk usage : Sets the upper limit of the capacity of the usable disk in %.
The figure above is set to 90%. Therefore, when the disk usage reaches 90% of the
total disk capacity, the setting of the minimum disk usage is automatically deleted to
secure the capacity of the disk.
⑩ Image storage location : Choose where you want to save the image.
① Add
After entering the order code and the order description, select the part and click the
Add button, a new inspection code will be generated. If you press the Cancel button,
the pop-up window will disappear. Select a region from the mapping list and click the
Delete button to delete the region from the mapping list.
② Modified : You can modify the mapping information in the same way when you select
the mapping information and click the Modify button.
③ Delete : You can delete the mapping information by selecting the mapping
information and clicking the Delete button.
(4) Marking
The already entered marking information is displayed. You can set marking information
with the Add and Delete buttons.
(5) Usage information
Displays the number of scans and erases of the equipment and cassette, and displays
the version information of the SW.
- DICOM
You can make settings related to DICOM service.
③ Delete : If you select the item you want to delete, it is activated and you can modify
the work list, storage, and print.
(3) DICOM-related automatic request time, character set, Calling AE Title, and whether to
compress.
- Anatomical
(1) You can modify BodyPart and Projection according to MainBodyPart. Click the Modify button
and the following window will appear.
activated and the content applied at the time of click changes. When the
button is clicked, the window disappears.
(3) The Edit All button. When clicked, the following window will appear. You can change
the PM Tube value, resolution and image parameter value.
-Device info
(1) The resolution according to the cassette size is displayed, and if the calibration is
completed, it is marked as 'X' if it is not completed with '0'.
(2) If applicable, write down the Mammo Licensky and press the Ac
1.7 Cautions for USB connection between SUPiA CR SCANNER and PC for SUPiA gram
If you have purchased this optional Viewer S/W, please refer to the below.
Click Setting Icon to register a new ID that will be used in gram viewer.
Click Add to register a new user in the Account tab and then create the ID and password.
*Please remember your password as you log in with this account as gram Viewer
If you have added an account in the console software (SUPiA gram), close the window and then run
gram viewer, and place your mouse on the Setup button located at to top left of the screen.
If you activate the Set up botton, a screen like the one above appears.
Input the IP address of the Console PC, default port: 219
(If you don’t know your Ip address, please refer to below).
Connect to network and sharing center from the control panel and click the wifi connection button
above.
Check my IP address.
You have to enter added account in Console Software, not ID:admin PW:0000
The ID entered when logging into gram viewer is displayed at the top of the screen.
Click 'Today' tab, you will get the calender and select the date. And click 'OK' button.
If you want to open another patient’s image, click down arrow then name list appears.
2.1.3 Tools
Contrast/Bright Reset
2.1.4 Setting
1) Option
You are able to change the color of Markings, Line and Text as well as the
language and font in Option tab.
2) DICOM
You can configure the DICOM printer in this window tab. There are more settings that character set,
Image compression type.
2.1.5 Export
In what format will the iamge be exported? (DICOM format, Image format, Whether to
3
include the viewer?)
When you finish selecting the image to be exported and the addition as above and click the ‘OK’
button located at the bottom right, the above window.
You can check the number of exported images, and information including the patient name is
displayed in the upper left corner.
2.1.6 Print
If you want to print to a printer, press the button at the bottom left.
1) Printer Type
You can choose 2 types of printer to print.
Standard printer refers to a network printer with a PC connected to it, and DICOM printer is an
abbreviation for Digital imaging and Communications in Medicine, which applies a kind of standard
communication protocol that is compatible with image information between medical devices.
If you want to output DICOM printer, please press the setting icon located in the upper right
corner. After selecting DICOM tab, please enter DICOM printer information and start ping test.
When all information is entered correctly and the connection is complete, the following notification
2) Paper size
If you selected the type of printer to print, select the paper size. You can select six types, in inches.
If the actual paper size differs from the selected paper size, the DICOM printer will display
this error, so check the paper size again and print it out.
3) Zone separation
You can place more than two pictures to print, and you can adjust the position be dragging the
pictures to print.
4) Option
You can print out a logo or text by inserting it into the image.
-Logo
-Text
You can insert letters in the image or adjust font size and only fill in the required items through the
checklist.
5) Patient Information
6) Output setting
7) Tools
Pan Reset
Magnify Contrast/Bright
8) Thumbnail
The images for that patient appear listed. If you have a lot of images, use the scroll to check.
If the ping test is carried out normally at 1) , press the button on the bottom right after all