GOT1000 Quick Start Guide
GOT1000 Quick Start Guide
GOT1000 Quick Start Guide
uick
G
uide
1
1
Creating project data
2
2
Transferring project data
3
3
Trying to operate the GOT
Quick Guide
Introduction
Appendix
For lamp
switch and numerical display
To be the best!
1
3
2
4
GT Designer2 Version
Screen Design Manual (manual number: SH-080530ENG)
For details, refer to
Reference
For GOT, the factors (such as swtiches and lamps mentioned above) which can be placed on
screen to display actions and set functions are called objects.
Object
Term explanation
POI NT POI NT
P.15
Reference
P.19
Reference
P.21
Reference
P.22
Reference
9
@
@
GOT Quick Guide
1. Creating a screen
2.Setting object functions
3.Setting the position of connection
4.Saving project data
Creating project data
1
1
1-2. Types of objects
The objects can be used in GT Designer2 are listed as below.
Bit switch
The bit device turns
ON/OFF when touching
the switch.
ON display OFF display
1.Switch 3. Numerical display
2. Lamp
Bit lamp
The lamp turns ON/OFF
according to bit devices
ON/OFF.
Numerical display
The data stored in the devices
of programmable controller
(Q series) is displayed.
[Objects] list
The objects mentioned in this guide are explained as below.
ON display OFF display
GT Designer2 Version
Screen Design Manual (manual number: SH-080530ENG)
For details, refer to
Reference
@
@
10
GOT Quick Guide
1. Creating a screen
2.Setting object functions
3.Setting the position of connection
4.Saving project data
1
1
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
1-3. Creating a new project
Starting GT Designer2.
When starting the GT Designer2 to create a new project, the system environment setting screens 1~9
will appear as below, select the [Next] button to proceed to a new screen.
The system includes the following items
GOT(GT15) RS-232 cable
(GT01-C30R2-6P)
Programmable controller(Q series)
2. Starting screen of the project creation wizard
Use project creation wizard to create. Click the [Next] button.
Select type and color setting for the GOT being used.
3. System setting screen of GOT
GOT type:[GT15**-V(640480)]
Color settings:[256 colors]
Select
Select
Click!
Click!
MEMO MEMO
A new project can also be created
without using wizard.
1.Project selection dialog box
Select [New].
Click!
11
@
@
GOT Quick Guide
1. Creating a screen
2.Setting object functions
3.Setting the position of connection
4.Saving project data
Creating project data
1
1
Select the connection I/F for the controller in [5].
Select communication driver for the controller in [5].
7. Setting screen for communication driver of the controller
6. I/F setting screen for controller
Select the controller of GOT.
5. Setting screen for controller
Controller: [MELSEC-QnA/Q
MELDAS C6*]
I/F: [Standard I/F (standard RS-232)]
Communication driver:[A/QnA/Q CPU, QJ71C24]
Select
Select
Select
Click!
Click!
Click!
When the following screen appears, click the [Next] button after checking the displayed contents are OK.
4. Confirmation screen for system setting of the GOT
Click!
Reference
For details on communication
driver, refer to
GT Designer2 Version
Basic Operation/Data Transfer Manual
(Manual number: SH-080529ENG)
GOT1000 series Connection Manual
(Manual number: SH-080532ENG)
@
@
12
GOT Quick Guide
1. Creating a screen
2.Setting object functions
3.Setting the position of connection
4.Saving project data
1
1
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
Set [Switch Device] in [Base Screen].
9. Setting screen for screen switch device
Base Screen: [GD100]
Select
Click!
MEMO MEMO
Easy
M0
bit momentary
OFF (red)ON (Cyan)
Stop
Setting contents of the switch
(the second one)
Easy
Select
Device
Action
Color of the switch
Text
Select
19
@
@
GOT Quick Guide
2. Setting object functions
Creating project data
1. Creating a screen
3.Setting the position of connection
4.Saving project data
1
1
2-2. Setting lamps
Place and set the lamp (bit lamp).
Base
Select [Object]-[Lamp]-[Bit Lamp] from the menu.
Place the lamp. The cursor will change to a cross shape.
Move the cursor to the proper position and then click.
(After placement, right click to exit arrangement mode.)
Step
Set functions for the placed lamp.
Double click the lamp.
A dialog box appears. Set devices on basic page.
Right
click!
Click!
Double
click!
Click!
Click!
Set
[Y0010]
Click!
1
2
3
4
Step
Step
Step
@
@
20
GOT Quick Guide
2. Setting object functions
1. Creating a screen
3.Setting the position of connection
4.Saving project data
1
1
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
Click!
End
Select
Select
Select
Select
Device: D10
Color: (purple)
Size: 22
Shape:Frame: Frame_1
Frame: (purple)
Setting contents of the numerical display
Review
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
After selecting the bit switch [RUN], click of shape in property list. The image list appears.
The guide explains how to create an exquisite screen.
Create an exquisite screen by using the library and changing the font.
Change the Shape by using the library.
Step
Select [Library] list in image list of figure.
Click of [Library] and select figure type, then select the parts to be changed.
Completion
example
* As an example, [Real Push Figure] is selected here.
1
2
Step
Click!
Click!
Click!
Click!
Click!
Click!
Click!
25
@
@
GOT Quick Guide
2. Setting object functions
BREAK TI ME
1. Creating a screen
3.Setting the position of connection
4.Saving project data
1
1
Change the text font and color of [Operation Switch] in property list.
Select the text of [Operation Switch].
Use fonts to change text.
Delete the text input for the switch from property list.
* No need to execute the operation when the text of switch are supposed to be saved.
When the status becomes ON, change the
[Operation Switch] under ON status by taking
Select [12dot HQ Mincho] Select [Sap green]
Click!
Click the [Status] in property list and select [ON].
With the same procedure
3
2
1
Step
Step
Step
3 1
Step Step
~ .
Delete
Click!
End
Click!
Click!
Click!
End
@
@
26
GOT Quick Guide
2. Setting object functions
BREAK TI ME
1. Creating a screen
3.Setting the position of connection
4.Saving project data
1
1
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
Draw the figure frame and select [Figure]- [Rectangle] from the menu.
Change the setting of figure frame and double click the frame.
Change the width and color of the lines.
Enclose the switch in the frame.
The cursor will change to a cross shape.
Move it to the starting position of the figure, and then drag it to draw figure.
(After placement, right click it to exit configuration mode.)
Adding the frame
With the same procedure
Referring to the setting procedure, change the settings of
stop switch, lamp display under operation, and so on, and
create the same screen as the completed example.
1
3
4
2
Step
Step
Step
Step
End
Click!
Click!
Right
click!
Double
click!
Select
Select
27
@
@
GOT Quick Guide
2. Setting object functions
BREAK TI ME
1. Creating a screen
3.Setting the position of connection
4.Saving project data
1
1
Using the library
Listing the library by subject
The library introduced on page 23 has various figures.
The figures listed by subject are shown as following. (The figures can also be listed by function).
The example for setting GOT 1000 series tool library (lamp g switch)
The address for downloading GOT 1000 series library
The necessary parts can be downloaded
from MELFANSweb page of the relevant
information website of Mitsubishi electric FA
equipment.
You can download them after registering as
a member of FA-LAND (free).
@
@
28
GOT Quick Guide
3. Setting the position of connection
1. Creating a screen
2. Setting object functions
4.Saving project data
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
Use [Communication Settings] of GT Designer2 to set GOT communication interface.
GT Designer2 Version
Screen Design Manual (manual number: SH-080530ENG)
For details, refer to
Reference
End
Display [Communication Settings] window.
There are two methods to recall [Communication Settings] menu.
Click [Common]-[System Environment]
Double click [System Environment] in work space
Check if the setting contents are the same as those set in project creation wizard of P10 to P12.
Click to change detail setting of the driver.
The screen of detail setting for the driver appears. Make a selection in the pull-down menu to change
baud rate.
* If there is no need to change the detail setting of the driver, this operation is unnecessary.
1
2
3
Step
Step
Step
Double
click!
Click!
Double
click!
Click! Confirm Confirm
Select
29
@
@
GOT Quick Guide
BREAK TI ME
3. Setting the position of connection
1. Creating a screen
2. Setting object functions
4.Saving project data
1
1
GT Designer2 Version
Screen Design Manual (manual number: SH-080530ENG)
For details, refer to
Reference
The following window appears. Select [Yes].
[Communication Settings] screen appears. Check if the standard I/F-1
is the same with the setting in .
3
Change the connection target!
The operations explained in this guide are taken under the condition that RS232 and the program-
mable controller (Q series) are of direct CPU connection. When connecting it with other equipment
than the programmable controller (Q series) or changing the connection methods, please make the
changes according to the procedure as below.
* The guide changes the connection position to direct CPU connection via [MELSEC-FX] and
[RS232] , and then takes this as example to explain.
The same as step in the previous page. Select [Common]-[System Environment] to display [System
Evironment] window. After the [System Evironment] window appears, change the CH1 setting of [Controller
Type] to the desired equipment, and then click [OK] button.
1
2
1
Step
1
Step
Step
Step
Click!
Click!
Click!
@
@
30
GOT Quick Guide
BREAK TI ME
3. Setting the position of connection
1. Creating a screen
2. Setting object functions
4.Saving project data
1
1
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
The same as step of page 28. Select menu [Common]-[System Environment] to display [System Environ-
ment] window. After the [System Environment] window appears, please change the setting of [GOT Type] to the
desired equipment, and then click [OK] button.
The following window appears. Select [Yes].
Change GOT type!
Click!
The screen size will be larger as the GOT type changes, so the base screen needs to be placed.
Select the position to place and then click .
* When the screen size does not become larger as the GOT type changes, this operation is unnecessary.
The GOT type is changed.
Click!
You can change the GOT type in the setting of project according to the following procedure.
* The guide changes the GOT type from [GT15**-V(640480)] to [GT15**-S(800600)], and
then takes this as example to explain.
1 1
2
3
4
Step
Step
Step
Step
Click!
31
@
@
GOT Quick Guide
BREAK TI ME
3. Setting the position of connection
1. Creating a screen
2. Setting object functions
4.Saving project data
1
1
The [Communication Settings] screen appears. Click after changing the setting contents.
* If [No] is selected in , this operation is unnecessary.
The following dialog box appears. Select [Yes] to set the the Communication Setting and select [No] to skip. 5
6
Step
5
Step
Step
Click!
GT Designer2 Version
Screen Design Manual (manual number: SH-080530ENG)
For details, refer to
Reference
@
@
32
GOT Quick Guide
4. Saving project data
1. Creating a screen
2. Setting object functions
3. Setting the position of connection
1
1
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
Save the created project data.
End
Press the [Save] button after selecting or inputting the saving address and the file name.
Select [Save As].
Select
Specify
Keyboard input
Saving address: [GOT data]
File name: [Introduction data]
File type : [GT Designer2 Files (*. GTE)]
saving address
MEMO MEMO
The name of the folder used in this guide
is GOT data. Any folder name and
saving address can be set.
1
2
Step
Step
Click!
33
@
@
GOT Quick Guide
BREAK TI ME
4. Saving project data
1. Creating a screen
2. Setting object functions
3. Setting the position of connection
1
1
Select [View]-[Preview] from the menu.
Display preview
The created screen data images can be checked by preview.
Switch the [State] in screen preview to check the ON and OFF screen status respectively.
ON
1
2
Step
Step
Click
Click
OFF
Click
@
@
34
Transferring project data
GOT Quick Guide
1. Connecting personal computer and GOT
2. Transferring data
3. Connecting GOT and programmable controller
2
2
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
Connecting personal computer and GOT
* To make USB communication with GOT, the USB driver must be installed.
The data can be transferred by connection methods other than USB cable or by using CF card.
Connecting to
USB connector
When using USB cable
Connecting to
USB connector
GT Designer2 Version
Basic Operation/Data Transfer Manual (manual number: SH-080529ENG)
For details, refer to
Reference
35
@
@
Transferring project data
GOT Quick Guide
2
2
3.Connecting GOT and programmable controller
1.Connecting personal computer and GOT
2.Transferring data
2-1. Setting communication between personal computer and GOT
Set the communication that is used to transfer data to GOT by personal computer.
Select [To/From GOT] in the menu.
Set the communication for the personal computer
transferring data to GOT.
Test the communication to check the personal computer is correctly connected with GOT.
End
Select the connection method, and the click
after it changed.
When the personal computer is correctly
connected with GOT, the above dialog box will
appear.
If errors appear, please check the actual
connection method and setting contents.
1
2
3
Step
Step
Step
Click!
Click!
Click!
Click!
Select
@
@
36
GOT Quick Guide
2
2
3. Connecting GOT and programmable controller
1. Connecting personal computer and GOT
2. Transferring data
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
2-2. Installing OS
Install standard monitor OS, communication driver, extended function OS and option function OS in
GOT. The settings mentioned in this guide do not belong to extended functions or option functions, so
only the standard monitor OS and communication driver OS will be selected to install.
Installation of OS
Install standard monitor OS and communication driver.
Execute the installation according to the displayed windows.
* Never turn off the power during transferring data.
End
MEMO MEMO
Standard monitor OS [All Items]
Communication driver[A/QnA/QCPU, QJ71C24]
Reference
For details of OS and communication
driver, refer to
GT Designer2 Version Basic Operation/Data Transfer
Manual
(Manual number: SH-080529ENG)
GOT1000 Series Connection Manual
(Manual number: SH-080532ENG)
The OS used to monitor for GOT or communica-
tion driver is not installed in GOT.
So, this operation should be done only once
before monitoring for the first time.
1
2
Step
Step
Click!
Select the
desired item
Click!
Click!
Click!
37
@
@
Transferring project data
GOT Quick Guide
2
2
3.Connecting GOT and programmable controller
1.Connecting personal computer and GOT
2.Transferring data
Check OS is correctly installed in GOT.
Check it is the same as the installation in of page 36.
(Standard monitor OS, communication driver)
Click [Drive information] tab.
In this guide, the standard monitor OS and communication driver are installed in [Drive C].
Select the drive name as [C: Built-in flash memory], and click it for details.
End Standard monitor OS
Standard monitor OS [03.10.00]
System Screen Information [03.10.00]
System Screen Data [03.10.00]
Standard Font
TrueType Numerical Font [03.10.00]
Communication driver
A/QnA/Q CPU, QJ71C24 [03.10.00]
The version is GT Design2 Version 2.69X.
1
2
Step
1
Step
Step
Click!
Click!
Specify
@
@
38
GOT Quick Guide
2
2
3. Connecting GOT and programmable controller
1. Connecting personal computer and GOT
2. Transferring data
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
2-3. Downloading project data
Download project data to GOT.
GT Designer2 Version
Basic Operation/Data Transfer Manual (manual number: SH-080529ENG)
For details, refer to
Reference
Execute the installation according to the displayed windows.
End
Click [Project DownloadGOT] tab, and check all displayed project data to start downloading. 1
2
Step
Step
Click!
Select
Click!
Click!
Click!
39
@
@
Transferring project data
GOT Quick Guide
2
2
1.Connecting personal computer and GOT
2.Transferring data
3. Connecting GOT and programmable controller
* When installing communication unit or connecting programmable controller on GOT, always shut off
power supply used by the system beforehand.
3-1. Checking the communication unit
The communication unit can be installed in the GOT extension unit connector when necessary.
3-2. Connecting programmable controller
Use cable to connect GOT and programmable controller. For the necessary equipment, refer to the
description on page 4.
Connecting to RS-232 interface
or
RS-232 communication unit
When connecting the cable to RS-232 communication unit When connecting the cable to RS-232 interface
Connecting
to CPU
module
GOT1000 Series Connection Manual (manual number: SH-080532ENG)
For details, refer to
Reference
@
@
40
GOT Quick Guide
2
2
1.Connecting personal computer and GOT
2.Transferring data
3.Connecting GOT and programmable controller
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
3-3. Checking the communication between GOT and programmable controller
I/O check
I/O check is a function to check whether the communication between GOT and programmable controller
is normal or not.
If the check is normally completed, the settings of communication interface and the connection of cable
are correct.
Select [Debug & self check]-[Self check] from the menu.
Display main menu of utility.
Touch upper left corner of the screen, or touch both upper left and upper right corners simultaneously. ( * )
*The touching position changes according to types of GOT.
[The factory setting for the touching position]
gGT1595Touch the upper left corner of GOT screen
gGT1585, GT157, GT156, GT155: Touch the upper left & right corners
of GOT screen at the same time
*The touching position can be changed through
[Common]-[System Environment]-[GOT Setup] of the drawing software.
GT Designer2 Version
Screen Design Manual (manual number: SH-080530ENG)
For details, refer to
2
1
Step
Step
Reference
41
@
@
Transferring project data
GOT Quick Guide
2
2
1.Connecting personal computer and GOT
2.Transferring data
3. Connecting GOT and programmable controller
Sequence program
The following is the sequence program used by the examples in this guide.
Write the program into the programmable controller by using GX Developer before proceeding to STEP3.
The result of I/O
check appears.
Touch [I/O check] - [CPU] of checking channel. 3
Step
GT15 User's Manual (Manual number: SH-080528ENG)
For details, refer to
Reference
O
MO M1
Y1O
Y1O
4
Y1O
MOV K8888 D1O
7
Y1O
MOV K6666 D1O
1O LND
@
@
42
GOT Quick Guide
1. Displaying the created screen
2. Pressing the Operation switch
3. Pressing the Stop switch
3
3
Trying to operate the GOT
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
Turn on the power of GOT.
The screen created is displayed on GOT.
The actions of the set objects are as below.
Operation Switch After touching, starts operating.
Stop Switch After touching, stops operating.
Operation Lamp When operating, lights up the lamp.
Numerical Display Displays the numerical values stored in programmable controller.
The action images of every object will be explained from the next page.
* The sequence program that drives the programmable controller of the GOT screen on this page is the
same as the program explained on the previous page.
O
MO M1
Y1O
Y1O
4
Y1O
MOV K8888 D1O
J
Y1O
MOV K6666 D1O
1O LND
Sequence program
GT Designer2 Version
Screen Design Manual (manual number: SH-080530ENG)
For details, refer to
Reference
43
@
@
GOT Quick Guide
2. Pressing the Operation switch
3. Pressing the Stop switch
1. Displaying the created screen
3
3
Trying to operate the GOT
GOT: Touch the Operation Switch. Sequence program:
O
4
J
1O
MO M1
Y1O
Y1O
Y1O
MOV K8888 D1O
Y1O
MOV K6666 D1O
LND
GOT: The Operation Lamp becomes ON. Sequence program:
The device Y10 becomes ON,
so the value [6666] is stored in the device D10.
O
4
J
1O
MO M1
Y1O
Y1O
Y1O
MOV K8888 D1O
Y1O
MOV K6666 D1O
LND
GOT: The numerical display is [6666].
The device M0 becomes ON,
so the device Y10 also becomes ON.
@
@
44
GOT Quick Guide
3. Pressing the Stop switch
1. Displaying the created screen
2. Pressing the Operation switch
3
3
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
O
4
J
1O
MO M1
Y1O
Y1O
Y1O
MOV K8888 D1O
Y1O
MOV K6666 D1O
LND
Sequence program:
The device Y10 becomes OFF,
so the value [3333] is stored in the device D10.
O
4
J
1O
MO M1
Y1O
Y1O
Y1O
MOV K8888 D1O
Y1O
MOV K6666 D1O
LND
GOT: The numerical display is [3333].
GOT: Touch the Stop Switch. Sequence program:
The device M1 becomes ON,
so the device Y10 is OFF.
GOT: The Operation Lamp becomes OFF.
45
@
@
Appendix
GOT Quick Guide
2. More about functions
1. More about screen
Besides the objects explained before this page, basic figure and other objects can also be added, and
the screens as below can be created.
Screen example 1
Screen example 2
@
@
46
GOT Quick Guide
1. More about screen
2. More about functions
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
GOT features lots of practical functions.
The following shows a number of the functions.
Lamp, switch
Touch the data set switch to change the value
of word device.
Touch the special function switch to switch the
screen to applicable menu and so on.
Data set switch
D100:
200 350
Special function switch
Touch the go to screen switch to switch basic
screen and window screen.
Go to screen switch
Data change switch
GOT displays the specified key window in the specified
position, and the cursor on the corresponding object.
Base 1 Base 2
Touch the bit switch to turn ON/OFF the bit device.
Bit switch
M0:ON OFF
Switch the station number of the controller that
is monitored.
Change station No. switch
Change the
monitor target
Change the lighting color of lamp.
Lamp display
Key cord switch
Used as the keys for numerical/ASCII input.
47
@
@
Appendix
GOT Quick Guide
1. More about screen
2. More about functions
Numerical value, character display
GOT displays the values of multiple devices in form of list.
GOT displays the value of device in character.
Data list display ASCII display
Input the character codes in the device.
ASCII input
Write the value into the device.
Numerical input
GOT displays date/time.
Time display
GOT displays the value of device with digit.
Numerical display
Comment display
GOT displays comment.
D10:4241H(BA)
D11:4443H(DC)
D10:4241H(AB)
D11:4443H(DC)
@
@
48
GOT Quick Guide
1. More about screen
2. More about functions
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
Alarm
When alarm occurs, GOT errors, communication errors
and the message created by users will be popped up.
And the alarm will be displayed hierarchically.
User alarm display System alarm display
Alarm history display
Advanced alarm popup display
Scrolling alarm display
Advanced alarm display
Parts
Parts movement display Parts display
GOT displays the registered parts. GOT displays the moving parts.
The device of monitor is not set
Part 1 Part 2
When alarm occurs, the message created by users
will be displayed.
When alarm occurs, GOT errors or communication
errors will be displayed.
02/04/18 13:25:40
Production line stops
307 Monitor device
not set
Display the alarm in landscape orientation.
Time Message
Production Line A Stops
Exceeds Upper Limit
Motor Trips
13:25
13:05
13:03
Time Message
Production Line A Stops
Exceeds Upper Limit
Motor Trips
13:25
13:05
13:03
Time Message
Production Line A Stops
Exceeds Upper Limit
Motor Trips
13:25
13:05
13:03
Error Error occurs
When alarm occurs, GOT errors, communication errors
and the message created by users will be displayed in
form of log. And the alarm will be displayed hierarchically.
When alarm occurs, the message created by users will
be displayed in form of history.
Time Message
Production Line A Stops
Exceeds Upper Limit
Motor Trips
13:25
13:05
13:03
49
@
@
Appendix
GOT Quick Guide
1. More about screen
2. More about functions
Graph, meter
Trend graph display Line graph display
Level display Panel meter display
GOT displays the value of device in meter.
GOT displays the value of device in trend graph.
GOT displays the value of device in ratio
comparing the whole.
GOT displays the value of device in line graph.
Scatter graph display Historical trend graph display
Bar graph display
GOT displays the value of device in bar graph.
GOT displays the value of device in scatter graph.
Statistical graph display
According to the ratio comparing with the whole,
GOT displays the value of device in graph.
Pie chart
Bar chart
GOT displays the data collected by logging
function so far in trend graph.
@
@
50
GOT Quick Guide
1. More about screen
2. More about functions
I
n
t
r
o
d
u
c
t
i
o
n
S
T
E
P
1
C
r
e
a
t
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
2
T
r
a
n
s
f
e
r
r
i
n
g
p
r
o
j
e
c
t
d
a
t
a
S
T
E
P
3
T
r
y
i
n
g
t
o
o
p
e
r
a
t
e
t
h
e
G
O
T
A
p
p
e
n
d
i
x
M
o
r
e
f
u
n
c
t
i
o
n
s
Formula
Advanced recipe function Recipe function
ConditionAction
Time action function Logging function
Collect and store the value of device.
Execute the operations such as device writing
at specified time.
Read
Read
Write
* Only several of the functions will be explained.
External I/O * Only several of the functions will be explained.
Barcode Operation panel
Video display Report
Write
Monitor the status of device, and read/write the
value of device when conditions are met.
One value can be specified to a device.
Monitor the status of device, and read/write the
value of device when conditions are met.
Multiple values can be specified to a device.
The value of device can also be read/written by
using the utility of GOT.
Collect and print the data about production
management and production status and so on.
Write the data that is read by barcode reader into
the device.
Use operation panel to execute the device writing.
GOT displays the video image.
51
@
@
Appendix
GOT Quick Guide
1. More about screen
2. More about functions
GT Designer2 Version
Basic Operation/Data Transfer Manual (manual number: SH-080529ENG)
GT Designer2 Version
Screen Design Manual (manual number: SH-080530ENG)
For details, refer to
Reference
Others
System monitor Backup/Restore
Language switching Document display
Monitor the status of devices in programmable
controller.
Switch and display multiple languages. GOT displays the file data on GOT.
M10 ON
M20 OFF
D100255
Backup
Restore
* Only several of the functions will be explained.
Ladder monitor Network monitor
GOT displays the operation status of the
sequence program.
Gateway function MES interface
Perform remote monitoring and remote
maintenance for production field from the office.
MITSUBISHI programmable controller
D100 250
OMRON programmable controller
TIM50 330
Ethernet
Back up setting contents for the controller,
and restore through GOT.
Monitor the network status of MELSECNET/H,
MELSECNET/10, MELSECNET ( ), MELSECNET/B.
Synchronization of the GOT controller data and the
information systems data library (execution system)
can be done without using the communication
gateway.
Quick
Guide
1
1
Creating project data
2
2
Transferring project data
3
3
Trying to operate the GOT
Quick Guide
Introduction
Appendix
For lamp
switch and numerical display
To be the best!