Summary
- System components
- System Setup
Desktop .......................................................................................................................................................................................... 5
- Troubleshooting
.......................................................................................................................................................................... 11
- Product Specification
............................................................................................................................................................... 15
............................................................................................................................................................... 16
.................................................................................................................................................... 17
System components
9
1
5
The tablet is specifically adapted to run the CoRehab Platform software and the
Back Office. On the back of the tablet there is a support stand you can open. Be
sure to read the following before connecting anything to the tablet.
1
2
3
4
5
6
7
8
9
USB HUB: connect to the USB port next to the power button
AC cable: connect to the lateral part of the tablet to recharge it
Display button: used to switch from internal to external display
Volume buttons: used to change the volume from the tablet
AC adapter: connect it into AC outlet to recharge the tablet
HDMI cable: optionally use HDMI to connect to an external display
Sensors
on / off
System components
x2
EN
x2
M
x2
x2
The straps are used to secure the sensors on the body of the user.
Place the strap on the body part and use the velcro to close the strap.
CoRehab Platform comes with 8 straps: 1 green for chest, 1 green for
waist, 2 orange for thigh, 2 yellow for calf or arms, and 2 for wrists.
To use the remote with the tablet, be sure the infrared dongle is
connected. For the best use of the remote, follow these guidelines:
Avoid blocking the signal between the remote and the dongle.
The optimal distance is not more than 3 meters.
Avoid bright light sources behind, or near the display or remote.
Avoid highly reflective surfaces near the infrared dongle or the
structure.
System setup
DONGLE BLUETOOTH
HUB USB
+
+
USB IR
3
3. OPTIONAL: You can use the tablet with
an external AV output, using the mini HDMI
cable to connect to a personal bigger display.
CAUTION: to prevent electric shock, match the wide blade of the plug to the wide slot and insert fully into outlet
Before switching on the tablet using the power button on the superior part,
use the usb port to connect the USB HUB.
After you switch on the tablet using the power button, you will see the main
screen. Ensure that the sensor and footboard are charged and you are ready
to use the software.
1
2
3
External Video
With the CoRehab Platform you have a powerful and ergonomic system
that can follow you around the center and at home, but if you want,
you can also use it connected to an external monitor or TV using the
miniHDMI cable.
To use it, connect the miniHDMI on the lateral port of the tablet using
the miniHDMI cable while the tablet and external display is already
turned on. You will see the images on the external display.
Alternativelly you can mirror the display: connect the miniHDMI on
the lateral port of the tablet using the HDMI cable when the tablet is
turned off. Now turn on the external display and the tablet. Now you
have mirror display on tablet and on external display.
CoRehab Platform
(from v2.1)
When you start the Platform you will see the image above where you
have to insert your personal code (given by physioteraphist optionally by
the bracelets) to proceed
After the login you will find the products you bought active and selectable
and the favorites bar where there are functions chosen as favourites.
To add a function to this bar you have to press the (i) button. (the button
right corner indicates when this is possible)
In the exercise screen you will see the movement you will perform
during the game. On the right of the screen you will see the instructions
of the exercises and information about # of reps, # of series, lenght of
program, and graphical representation (in %) of current daily program
progression.
When all is clear and you are ready to start press OK to proceed.
To create a new patient click on Add Patient (the bottom left icon) and on
the next page insert the patient data. After the creation you can click on the
patient, then click on the chosen day to add an exercise to the program.
Now you can scroll down until you find a movement and then you can drag
the type of exercise you want for selected movement to the right panel. To
reorder the selected exercises drag them up or down in the list on the right.
After an exercise session of Riablo, you can look at the results in the
Back Office.
The Riablosity indicates your overall score of the exercise.
The Precision is high if the user was near the perfect angle to reach.
The Stability indicates how stable the body was during the exercise.
The Accuracy is low if the user compensates too much.
Each result can be printed to be attached to the medical file of the user.
After the user performed a test with Check in Motion or with Back in Action
you can find the results in details in BackOffice. There youll find the score
for each test and with details of angles reached during the exercises.
Each result can be printed to be attached to the medical file of the user.
10
Troubleshooting
Before requesting service
Go through this section if you experience difficulty in operating the
system. Should any problem persist, contact the appropriate customer
service helpline:
turn off the system. Then with only the system and the TV connected,
touch the systems power button to turn the system back on. The video
output setting will automatically be reset to the standard resolution. If
the resolution of the video content is not supported by the TV in use, the
screen may go black. If this happens, try to change TV used for output.
The size of the video image and the TV screen do not match.
Check that the systems video output settngs are correct.
Check that the settings of the connected TV are correct. For details, refer
to the instrictions supplied with your TV.
With some video content, the screen size cannot be changed.
Power
The system does not turn on.
Check that the AC power cord is securely inserted in the system
and the electrical outlet.
Sound
Picture
There is no sound.
Check that the muting function on the TV speakers is turned on.
Also check that the volume is at the appropriate level.
The sound doesnt begin until the game begins.
If an audio device is connected, check the settings of the device.
For details refer to the instructions supplied with the audio device.
There may be a problem with the miniHDMI cable. Try using another
cable that is compatible with the system.
Some contents that support Dolby Digital, DTS, and other formats
may not produce audio from all channels.
Network
A connection to the network cannot be established.
Check that the WiFi is enabled on your computer.
Try to update the network scan if you are sure the system is turned on.
11
The following conditions can interfere with the operation of the remote:
1. Using the remote too close or too far from the system. The optimal
distance is between 1 and 4 meters.
2. Bright light sources (including sunlight) behind or near the TV,
shining towards the remote or reflecting off the TV screen.
3. Highly reflective surfaces near the dongles.
4. Sources of infrared light in the gameplay area such as electric,
propane or kerosene heaters, flames from fireplaces, candles,
stoves or other sources of heat.
5. Radio frequency interference may cause the Remote to work
erratically. Check for and turn off wireless devices such as cordless
phones, wireless computer keyboards mice or other similar
devices.
If you think any of these conditions are affecting the operation of the
remote, try removing or reducing the source of interference.
The following conditions can interfere with the operation of the sensors:
1. Using the sensors in an surround full of WiFi connections.
2. Using the sensors too far from the system. The optimal distance is
between 1 and 4 meters.
12
Troubleshooting
Remote controller
Other issues
Supported accessories
Printers
HP Deskjet series
Televisions
Samsung with FULL-HD compatibility
13
14
Warranty
WARRANTY
Product Specification
Dimensions
Measurements
Sensor: Pitch, Roll, Yaw [degrees]
Board: Roll, Pressure
W
Communication
Communication: Wireless Bluetooth 2.1
Adapter: Bluetooth 2.1 USB dongle
Power supply
Autonomy of battery: up to 3[hours] in streaming.
Recharge time: up to 3[hours] if sensor is completely discharged
Recharge method:
Sensors - Connecting the dock to AC using supplied USB cable.
Board - Connecting the Board to AC using supplied USB cable.
Tablet - Connecting the tablet to AC using the AC adapter.
Battery type: Board: 3.7[V] 1050[mAh] Lion.
Sensor: 3.7[V] 200[mAh] LiPo.
Voltage input: 5[V] DC
Rated current input: Board: 800[mA]. Sensor: 800[mA]
Updates method: Connecting the system to the internet.
Tablet:
Height 19,6 cm
Width 29,6 cm
Sensors
W
W
H
Environmental condition
Sensor:
Height 55 mm
Width 43 mm
Board:
Height 2,7 cm
Width 58,4 cm
Depth 36,4 cm
Functionality
Body attachment method: Velcro straps
15
On AC cables
Regulation
On the AC cables there are labels that indicates the purpose of each cable.
The system has been tested according to the standard ISO 9001 (2008) design
and manufacturing of electro-medical equipment for physiotherapy.
Registered by Board of Health as a class I-M medical device non-sterile and
without measurement functions.
Sensors
The Sensors labeled cable is used to connect the Dock to the tablet, AC
adapter or at the structure.
Tablet
The Tablet labeled cable is used to connect the Tablet to the AC adapter.
Board
The Board labeled cable is used to connect the Riablo Board, to the AC adapter.
On sensors
CPxxx.IS<i>
Copyright
On the sensors there are labels that indicates their product association and
product model.
Information and views expressed in this document, including URL and other
Internet website references, may change without notice. This document
does not provide you with any legal rights to any intellectual property in any
CoRehab product. You may copy and use this document for your internal,
reference purposes.
2015 CoRehab s.r.l.. All rights reserved. CoRehab and Riablo, are trademarks
of CoRehab.
This product incorporates copyright protection technology and intellectual
property rights. Reverse engineering or disassembly is prohibited.
CRxxx.BB
Behind the board there is a label that indicates the product association and
product model.
Device P/N
Corehab s.r.l.
Via Klagenfurt 62, 38121, Trento (TN), Italy
Phone
+39 0461 960157
Mail
[email protected]
VAT
02185760226
REF. CP0200
CoRehab Platform
MEDICAL DEVICE
CLASS I
The names of actual companies and products mentioned herein may be the
trademarks of their respective owners.
Europe and/or international patents pending.
lotto: 000000
16
WARNING
Motion Injuries and Eyestrain
WARNING - Seizures
Some people (about 1 in 4000) may have seizures or blackouts triggered by
light flashes or patterns, and this may occur while they are watching tv or
playing video games, even if they have never had seizure before.
Playing with the system can make your muscles, joints, skin or eyes hurt.
Follow these instructions to avoid problems such as tendinitis, carpal tunnel
syndrome, skin irritation or eyestrain:
Avoid excessive play. Follow the physio programs. Take your time, if you
feel tired take a break.
If your hands, wrists, arms or eyes become tired or sore during exercises,
or if you feel symptoms such as tingling, numbness, burning or stiffness,
stop and rest for several hours before exercising again.
If you continue to have any of the above symptoms or other discomfort
during or after play, stop playing and see a doctor.
Anyone who has had a seizure, loss of awareness, or other symptom linked
to an epileptic condition should consult a doctor before playing a video game.
Parents should watch their children play video games. Stop playing and
consult a doctor if you or your child has any of the following sympoms:
Convulsions - Eye or muscle twitching - Loss of awareness - Altered vision Involuntary movements - Disorientation - Muscle pain - Joint pain
WARNING
Active Medical Device
17
18
CoRehab srl
Via Klagenfurt 62
38121 Trento
ITALY
0039 0461 960157
[email protected]
p.iva 02185760226