GT3A 2AF20 Idec Datasheet Temporzador1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

GT3A Series Timers

GT3A Series — Analog Timers


Key features of the GT3A series include:
• 4 selectable operation modes on each model
• External start, reset, and pause inputs
• Panel mount or socket mount
• Large variety of timing functions
• Power and output status indicating LEDs

UL, c-uL Listed


File No. E55996

GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6


Operation Multi-mode Multi-mode with inputs (11 pins)
Time Range 0.05s to 180 hours
100 to 240V AC, 50/60Hz
Rated Voltage 12V DC
24V AC, 50/60Hz / 24V DC
125V AC/250V AC, 3A; 125V AC/250V AC, 5A;
Contact Ratings 30V DC, 1A (resistive load) 30V DC, 5A (resistive load)
Minimum Applicable
5V, 10mA (reference value)
G Load
AF20 (100V AC): 85 to 264V AC
Voltage Tolerance AD24: 20.4 to 26.4V AC/21.6 to 26.4V DC
Timers

D12: 10.8 to 13.2V DC


Error ±0.2%, ±10 msec (repeat, voltage, temperature)
Setting Error ±10% maximum
Reset Time 60msec maximum
Insulation Resistance 100MΩ minimum
Specifications

Between power and output terminals: 2,000V AC, 1 minute


Dielectric Strength Between contacts of different poles: 2,000V AC, 1 minute
Between contacts of the same pole: 750V AC, 1 minute
Delayed SPDT +
Delayed SPDT Delayed DPDT Delayed DPDT
instantaneous SPDT
10.8VA 13.5VA 14.4VA 4.7VA (100V AC, 60Hz),
Power Consumption (200V AC, 60Hz) (200V AC, 60Hz) (200V AC, 60Hz) 14.4VA (200V AC, 60Hz)
(approximate)
12VDC/1W 12VDC/1.1W 12VDC/0.8W
– 24VDC/0.7W 24VDC/0.6W 24VDC/0.6W
24VAC/1.2VA 24VAC/1.3VA 24VAC/1.3VA
Mechanical Life 10,000,000 operations minimum 5,000,000 operations minimum
Electrical LIfe 50,000 operations minimum (rated load) 100,000 operations minimum (rated load)
Weight (approximate) 63g 73g 79g 80g
Vibration Resistance 100m/sec2 (approximate 10G)
Operating extremes: 100m/sec2 (approximate 10G)
Shock Resistance Damage limits: 500m/sec2 (approximate 50G) GT3A Table of Contents
Operating Temperature –10 to +50°C Specifications — G-14
Operating Humidity 45 to 85% RH Part Number List — G-15
Storage Temperature –30 to +80°C Timing Diagrams/Schematics — G-16
Instructions: Setting Timer — G-22
Housing Color Gray
GT3 Accessories — G-48
GT3 Instructions: Wiring Inputs — G-50
GT3 Dimensions — G-52
Timing Diagrams Overview — G-4

G-14
Timers GT3A Series

Part Number List

Part Numbers: GT3A-1, -2, -3


Mode Of Time Complete Part No.
Rated Voltage Code Output Contact
Operation Range 8-Pin 11-Pin
AF20: 100 to 240V AC (50/60Hz) Delayed SPDT GT3A-1AF20 GT3A-1EAF20
250V AC, 3A, GT3A-2AF20 GT3A-2EAF20
30V DC, 1A Delayed SPDT +
A: ON-delay 1 0.05s. (resistive load) Instantaneous GT3A-2D12 GT3A-2ED12
B: Interval 1 to SPDT
AF20: 100 to 240V AC (50/60Hz) GT3A-2AD24 GT3A-2EAD24
C: Cycle 1 D12: 12V DC 180
D: Cycle 3 AD24: 24V AC (50/60Hz)/24V DC hours GT3A-3AF20 GT3A-3EAF20
240V AC, 5A,
24V DC, 5A Delayed DPDT GT3A-3D12 GT3A-3ED12
(resistive load)
GT3A-3AD24 GT3A-3EAD24
1. For wiring schematics and timing diagrams for GT3A-1, -2, -3, see pages G-16, G-17, or G-18 respectively.
2. For more details about time ranges, see instructions on page G-22.
3. For socket and accessory part numbers, see page G-48.

Part Numbers: GT3A-4, -5, -6


Mode of Time Complete Part No.
Rated Voltage Code Output Contact Input
Operation Range A (11-pin) B (11-pin)
A: ON-Delay 2 GT3A-4AF20 GT3A-4EAF20
AF20: 100 to 240V AC (50/60Hz)
B: Cycle 2 D12: 12V DC GT3A-4D12 GT3A-4ED12
C: Signal ON/OFF-Delay 1
D: Signal OFF-Delay 1 AD24: 24V AC (50/60Hz)/24V DC
GT3A-4AD24 GT3A-4EAD24
G
A: Interval 2 0.05 GT3A-5AF20 GT3A-5EAF20
250V AC, 5A, Start

Timers
B: One-Shot Cycle seconds Delayed
24V DC, 5A Reset
C: Signal ON/OFF-Delay 2 to DPDT
(resistive load) Gate GT3A-5AD24 GT3A-5EAD24
D: Signal OFF-Delay 2 180 hours
AF20: 100 to 240V AC (50/60Hz)
A: One-Shot AD24: 24V AC (50/60Hz)/24V DC GT3A-6AF20 GT3A-6EAF20
B: One-Shot ON-Delay
C: One-Shot 2 GT3A-6AD24 GT3A-6EAD24
D: Signal ON/OFF-Delay 3
4. For wiring schematics and timing diagrams GT3A-4,-5,-6, see pages G-19, G-20, and G-21 respectively.
5. For more details about time ranges, see instructions on page G-22.
6. A (11-pin) and B (11-pin) differ in the way inputs are wired.
7. For socket and accessory part numbers, see page G-48.
8. For the timing diagrams overview, see page G-4.

G-15
Timers GT3A Series
GT3A-4 Timing Diagrams

Delayed DPDT
(A Type) Note: T = Set time
(Contact Input) (Transistor Input) (B Type)
Ta = Shorter
than set time
Start Reset T = T' + T"
6 6 6
5 7 5 7 5 7
4 8 Reset Start Gate 4 8
4 8
ResetStartGate
3 9 3 9 3 9
2 10 2 10 2 10
Operation (-) 1 11 (+) 1 11 (+) (-) 1 11 (+)
Mode Selection (-)
POWER POWER POWER
Item Terminal No. Operation
Power 2-10 (POWER)
Start 2-6 (A)
5-7 (B)ON or L
Input

ON-Delay 2 Reset 2-7 (A)


6-7 (B)ON or L
MODE Gate 2-5 (A) ON or L
1-4
A Delayed 8-11(NC)
Contact 1-3
9-11(NO)
POWER
Indicator
OUT
Set Time T Ta T' T"
Note: While the gate input is on
during time-delay operation, the
POWER indicator flash rate slows down. G
Item Terminal No. Operation
Power 2-10 (POWER)

Timers
Start 2-6 (A)
5-7 (B)ON or L
Cycle 2
Input

Reset 2-7 (A)


6-7 (B)ON or L
MODE
Gate 2-5 (A) ON or L
B 1-4
Delayed 8-11(NC)
Contact 1-3
9-11(NO)
POWER
Indicator
OUT
Set Time T T T T T T T Ta T T T T’ T’’ T T T T T
Item Terminal No. Operation
Power 2-10 (POWER)
Start 2-6 (A)
5-7 (B)ON or L
Signal ON/OFF-Delay 1
Input

Reset 2-7 (A)


6-7 (B)ON or L
MODE
Gate 2-5 (A) ON or L
C 1-4
Delayed 8-11(NC)
Contact 1-3
9-11(NO)
POWER
Indicator
OUT
Set Time T T Ta T Ta T T T T’’ Ta
Item Terminal No. Operation
Power 2-10 (POWER)
Start 2-6 (A)
5-7 (B)ON or L
Signal OFF-Delay 1
Input

Reset 6-7 (A)


2-7
(B)ON or L
MODE
Gate 2-5 (A) ON or L
D 1-4
Delayed 8-11(NC)
Contact 1-3
9-11(NO)
POWER
Indicator
OUT
Set Time T Ta Ta T T’ Ta

G-19
GT3A Series Timers
Instructions: Setting GT3A Series Timers

Timed OUT Indicator POWER Indicator


(flashes during
time-delay period)

➃ Setting Knob

➂ Time Range Selector


➀ Operation Mode 1S, 10S, 10M, 10H
Selector
A, B, C, D

A
➁ Dial Selector
0-1, 0-3, 0-6, 0-18

Step 1. Desired Mode of Operation Selection Remarks


For Timers Mode of Operation ➀ Operation Mode Selector
ON-delay 1 A
GT3A-1 Interval 1 B
GT3A-2
GT3A-3 Cycle 1 C
Cycle 3 D
G ON-delay 2 A
The desired operation mode
can be selected from the A, B,
C, and D modes using the Oper-
Cycle 2 B ation Mode Selector. Change
GT3A-4
Timers

Signal ON/OFF-delay 1 C the operation mode from A to


Select the desired mode B, C, and D in turn by turning
Signal OFF-delay 1 D the operation mode selector
of operation.
Interval 2 A clockwise using a flat screw-
driver which is a maximum of
One-shot cycle B 0.156” (4mm) wide. The
GT3A-5
Signal ON/OFF-delay 2 C selected mode is displayed
in the window.
Signal OFF-delay 2 D
One-shot 1 A
One-shot ON-delay B
GT3A-6
One-shot 2 C
Signal ON/OFF-delay 3 D
Step 2. Desired Time Range Selection Remarks
Time Ranges ➁ Dial Selector ➂Time Range Selector
0.05 seconds to 1 second 0-1
0.05 seconds to 3 seconds 0-3
1S
0.05 seconds to 6 seconds 0-6
0.15 seconds to 18 seconds 0-18
0.1 seconds to 10 seconds 0-1
0.3 seconds to 30 seconds 0-3
10S
Select the time range 0.6 seconds to 60 seconds 0-6 The desired time range is
selected by setting both
that contains the desired 1.8 seconds to 180 seconds 0-18 ➁ Dial Selector and
time period. 6 seconds to 10 minutes 0-1 ➂ Time Range Selector.
18 seconds to 30 minutes 0-3
10M
36 seconds to 60 minutes 0-6
108 seconds to 180 minutes 0-18
6 minutes to 10 hours 0-1
18 minutes to 30 hours 0-3
10H
36 minutes to 60 hours 0-6
108 minutes to 180 hours 0-18
Step 3. Selection

Set the precise period of time desired by using the ➃ Setting Knob.

G-22
GT3 Series Accessories Timers
Accessories: GT3 Series

DIN Rail Mounting Accessories

Part Numbers: DIN Rail/Surface Mount Sockets and Hold-Down Springs


DIN Rail Mount Socket Applicable Hold-Down Springs
Style Appearance Use with Timers Part No. Appearance Part No.

GT3A-1, 2, 3 (8-pin)
GT3D-1, 2, 3 (8-pin)
8-Pin Screw Terminal GT3F-1, 2 (8-pin) SR2P-05
(dual tier) GT3W (8-pin)
GT3S

GT3A-1, 2, 3 (11-pin)
GT3A-4, 5, 6
11-Pin Screw Terminal GT3D-1, 2, 3 (11-pin) SR3P-05
(dual tier) GT3D-4, 8
GT3F-1, 2 (11-pin)
GT3W (11-pin)
SFA-203
GT3A-1, 2, 3 (8-pin)
GT3D-1, 2, 3 (8-pin)
8-Pin Fingersafe Socket GT3F-1, 2 (8-pin) SR2P-05C
GT3W (8-pin)
GT3S

G GT3A-1, 2, 3 (11-pin)
GT3A-4, 5, 6
GT3D-1, 2, 3 (11-pin)
11-Pin Fingersafe Socket SR3P-05C
GT3D-4, 8
Timers

GT3F-1, 2 (11-pin)
GT3W (11-pin)

GT3A-1, 2, 3 (8-pin)
GT3D-1, 2, 3 (8-pin)
8-Pin Screw Terminal GT3F-1, 2 (8-pin) SR2P-06
GT3W (8-pin)
GT3S
SFA-202
GT3A-1, 2, 3 (11-pin)
GT3A-4, 5, 6
GT3D-1, 2, 3 (11-pin)
11-Pin Screw Terminal SR3P-06
GT3D-4, 8
GT3F-1, 2 (11-pin)
GT3W (11-pin)

DIN Mounting Rail — BNDN1000


Length 1000mm

Installation of Hold-Down Springs


DIN Rail Mount Socket Panel Mount Socket
Insert the springs into the outer Hold-down Spring
slots with the projections Insert the springs
SFA-402
facing inside. into the slots.
Insert

8-pin Socket
SR2P-511
Socket SR3P-05 Hold-down Spring (sold separately)
SFA-203 (use two springs)
Socket SR2P-06 Hold-down Spring (sold separately)
SFA-202 (use two springs)

G-48
Timers GT3 Series Accessories

Panel Mounting Accessories

Part Numbers: Panel Mount Sockets and Hold-Down Springs


Panel Mount Socket Applicable HD Springs
Style Appearance Use with Timers Part No. Appearance Part No.

GT3A- (8-pin)
GT3D- (8-pin)
8-Pin Solder Terminal GT3W- (8-pin) SR2P-51
GT3F- (8-pin)
GT3S

SFA-402

GT3A- (11-pin)
GT3D- (11-pin)
11-Pin Solder Terminal SR3P-51
GT3W- (11-pin)
GT3F- (11-pin)

1. For information on installing the hold-down springs, see page G-48.

Part Numbers: Flush Panel Mount Adapter and Sockets that use an Adapter
Accessory Description Appearance Use with Timers Part No.
G

Timers
Panel Mount Adaptor for flush panel mounting All GT3 timers RTB-G01
Adapter GT3 timers

8-pin screw terminal All 8-pin timers SR6P-M08G

(Shown: SR6P-M08G
11-pin screw terminal for Wiring Socket All 11-pin timers SR6P-M11G
Adapter)

Sockets for use


with Panel
Mount Adapter
8-pin solder terminal All 8-pin timers SR6P-S08

11-pin solder terminal All 11-pin timers SR6P-S11

2. No hold down springs are available for flush panel mounting.

G-49
GT3 Series Dimensions Timers
Dimensions: GT3 Series

36.0 70.0
5.6

N40.0
Unit: mm
NOTE: GT3W series are UL Listed when used in combination
with following IDEC's sockets:
GT3W-A11, A33: SR2P-06* pin type socket.
GT3W-A11E, A33: SR3P-05* pin type socket.
(*-May be followed by A,B,C or U)
The socket to be used with these timers are rated:
-Conductor Temperature Rating 60ºC min.
-Use 14AWG max.(2mm2max.) Copper conductors only
-Terminal Torque 1.0 to 1.3 N-m

Analog GT3 Timer, 8-Pin with SR2P-06 Analog GT3 Timer, 11-Pin with SR3P-06
Analog Setting Type (When using DIN Rail) Analog Setting Type (When using DIN Rail)
When using BAA/BAP: 99 maximum When using BAA/BAP: 99 maximum
95 maximum 95 maximum

31.7
31.7

1.7
1.7

60
60
40

40

G Hold-
down
DIN Rail
Hold-
down DIN Rail
Spring spring
(SFA-202) (SFA-202)
18 18
Timers

1
1

36 8 64.2 13 22 36 8 64.2 13 22

Digital GT3 Timer, 8-Pin with SR2P-06 Digital GT3 Timer, 11-Pin with SR3P-06
When Mounting on DIN Rail When Mounting on DIN Rail
BNDN: 3.59" (92mm) Maximum BNDN: 3.59" (92mm) Maximum
3.43" (88mm) Maximum DIN Rail 3.43" (88mm) Maximum DIN Rail

(31.7mm)
1.23"
HD Spring (31.7mm) HD Spring

2.34" (60 mm)


SFA-202 SFA-202

(1.7mm) 1.23"
(60mm)
2.34"

1.56" 1.56"
(1.7mm)

(40mm) (40mm)
0.066"

0.066"
0.507" 0.507"
1.404" 2.5" (13mm) 2.5" (13mm)
0.039" (64.2mm) 1.404" 0.039" (64.2mm)
(36mm) (1mm) 0.702" (36mm) (1mm) 0.702"
(18mm) 0.039" (18mm) 0.039"
(1mm) (1mm)
0.858" (22mm) 0.858" (22mm)

Analog GT3 Timer, 11-Pin with SR3P-05 Digital GT3 Timer, 11-Pin with SR3P-05

Analog Setting Type (When using DIN Rail) When Mounting on DIN Rail
BAA or BAP: 105.5 maximum BNDN: 3.84" (98.5mm) Maximum
101.5 maximum DIN Rail
(BAA/BAP/BADA) 3.68" (94.5mm) Maximum
1.05" DIN Rail
1.29" (33mm) (27mm) BNDN
2.03"
1.56"
ø27

52
33

(52mm)
40

(40mm)
Hold-down 0.507"
Spring (SFA-203) 16.5 1.404" 2.42"
0.039" (64.2mm) (13mm)
0.644"
3

20 (36mm) (1mm) HD Spring 0.117"


36 8 64.2 13 (16.5mm)
28.5 SFA-203 (3mm)
0.78"
1.11" (28.5mm) (20mm)

G-52
Timers GT3 Series Dimensions

Panel Mount Adapter

Analog GT3 Timer, 8-Pin and 11-Pin with Digital GT3 Timer, 8-Pin and 11-Pin with
SR6P-S08 or SR6P-S11 SR6P-S08 or SR6P-S11
3.82" (98mm) Maximum
98 maximum Panel Mount
Panel Thickness 0.8 to 5mm Adapter Panel Thickness:
0.03" to 0.2" (0.8 to 5mm)

1.7
1.87" 0.066" 1.66"

42.5
(1.7mm)(42.5mm
48

(48mm)

48 11 61.2 Back Wiring Socket 1.87" (48mm) 0.12" Wiring Socket Adapter
(3mm) 2.39" (61.2mm)

Mounting Hole Layout


45

45

45 48N--3 G
Close Mounting

Timers
Single Mounting

Analog and Digital GT3 Timer, 8-Pin with SR6P-M08G


8-M3.5 Terminal Screw
Panel Thickness 0.8 to 5mm
44.6

3.5 max. 5.6 min.


3 4 5 6 ø3.6 min.
30.4
44.6

6.9 max.
2 1 8 7

7
9.8 × 3
80.5

Analog and Digital GT3 Timer, 11-Pin with SR6P-M11G


11-M3.5 Teminal Screws
45
16.7

3.5 max. 5.8 min.


2 1 11 7 6 ø3.6 min.
5
45
34

6.9 max.
4 3 8 9 10

30.5 7
92 8.5 × 4

G-53
General Instructions Timers
General Instructions for All Timer Series

Load Current Time Setting


With inductive, capacitive, and incandescent lamp loads, inrush current more The time range is calibrated at its maximum time scale; so it is desirable to
than 10 times the rated current may cause welded contacts and other undes- use the timer at a setting as close to its maximum time scale as possible. For
ired effects. The inrush current and steady-state current must be taken into a more accurate time delay, adjust the control knob by measuring the operat-
consideration when specifying a timer. ing time with a watch before application.

Contact Protection Input Contacts


Switching an inductive load generates a counter-electromotive force (back Use mechanical contact switch or relay to supply power to the timer. When
EMF) in the coil. The back EMF will cause arcing, which may shorten the con- driving the timer with a solid-state output device (such as a two-wire proxim-
tact life and cause imperfect contact. Application of a protection circuit is ity switch, photoelectric switch, or solid-state relay), malfunction may be
recommended to safeguard the contacts. caused by leakage current from the solid-state device. Since AC types com-
prise a capacitive load, the SSR dielectric strength should be two or more
times the power voltage when switching the timer power using an SSR.
Temperature and Humidity
Use the timer within the operating temperature and operating humidity Generally, it is desirable to use mechanical contacts whenever possible to
ranges and prevent freezing or condensation. After the timer has been stored apply power to a timer or its signal inputs. When using solid state devices, be
below its operating temperature, leave the timer at room temperature for a cautious of inrushes and back-EMF that may exceed the ratings on such
sufficient period of time to allow it to return to operating temperatures before devices. Some timers are specially designed so that signal inputs switch at a
use. lower voltage than is used to power the timer (models designated as “B"
type).
Environment
Avoid contact between the timer and sulfurous or ammonia gases, organic
solvents (alcohol, benzine, thinner, etc.), strong alkaline substances, or strong
acids. Do not use the timer in an environment where such substances are
prevalent. Do not allow water to run or splash on the timer.

Vibration and Shock


Excessive vibration or shocks can cause the output contacts to bounce, the timer
should be used only within the operating extremes for vibration and shock resis-
tance. In applications with significant vibration or shock, use of hold down
G springs or clips is recommended to secure a timer to its socket.
Timers

Timing Accuracy Formulas


Timing accuracies are calculated from the following formulas:

Repeat Error = ± 1 x Maximum Measured Value – Minimum Measured Value x 100%


2 Maximum Scale Value

Voltage Error
= ± Tv - Tr x 100%
Tr

Tv: Average of measured values at voltage V


Tr: Average of measured values at the rated voltage

Temperature Error
= ± Tt - T20 x 100%
T20

Tt: Average of measured values at °C


T20: Average of measured values at 20°C

Setting Error = ± Average of Measured Values - Set Value x 100%