480W DIN Rail Type DC-DC Converter: Series
480W DIN Rail Type DC-DC Converter: Series
480W DIN Rail Type DC-DC Converter: Series
■ Features ■ Applications
Compliance to EN50155 and EN45545-2 railway standard Bus,tram,metro or railway system
Width only 85.5mm Industrial control system
2:1 wide input range Semi-conductor fabrication equipment
-40~+80℃ wide operating temperature Factory automation
150% peak load capability Electro-mechanical
Current sharing up to 1920W(3+1) Wireless network
DC output adjustable Telecom or datacom system
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Protections: Short circuit / Overload / Over voltage /
Over temperature / Input reverse polarity/
Input under voltage protection
4KVdc I/O isolation(Reinforced isolation)
DC OK relay contact
Remote ON-OFF control
Operating attitude up to 5000 meters(Note.6)
3 years warranty
■ Description
DDR-480 series is a 480W DIN Rail type DC-DC converter with main features including DIN rail-type easy
installation, ultra slim width (85.5mm), 2:1 wide input voltage, fanless design, -40~+80℃ wide operating
temperature, 4KVdc I/O isolation, 150% peak load, current sharing,DC OK, adjustable output voltage
and full protective functions. This series of models has various input options: 16.8~33.6V / 33.6~67.2V /
67.2~154V and multiple output options: 12V / 24V / 48V and can be used for industrial & railway control,
security control, communication system and other fields. Suitable applications include to DC buck/boost
regulator, increasing system insulation level and voltage drop compensation along cable...etc.
■ Model Encoding
DDR - 480 B - 24
Output voltage(12/24/48Vdc)
Input voltage (B:16.8~33.6Vdc, C:33.6~67.2Vdc, D:67.2~154Vdc)
Rated wattage
Series name
DC OK
FG DETECTION
PWM CIRCUIT
O.L.P. CONTROL
O.V.P.
Remote
ON/OFF Control CURRENT P+
SHARE P-
Derating Curve
150
For 5 sec. (typ.)
100
Continuous
For others
LOAD (%)
-40 -20 0 20 40 55 60 80
(VERTICAL)
100
90
80 C/D Type
70 B Type
LOAD (%)
60
50
40
Peak Loading
601.2W for 12V o
720W for others
(150% load)
DC OK Relay Contact
Function Manual
1. Current sharing
(1) Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel) :
(2) The voltage difference among each output should be minimized that less than 0.2V is required.
(3) The total output current must not exceed the value determined by the following equation (Output current at parallel operation)
=(The rated current per unit) x (Number of unit) x 0.9.
(4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications.
(5) When in parallel operation, the minimum output load should be greater than 3% of total output load.
(Min. load > 3% rated current per unit x number of unit)
+ -
LOAD
+V o -V o P+ P- +V o -V o P+ P- +V o -V o P+ P- +V o -V o P+ P-
DC OK DC OK DC OK DC OK
DC OK DC OK DC OK DC OK
Vo Adj. + Vo Adj. + Vo Adj. + Vo Adj. +
Remote ON-OFF
Output Status
(TB1 PIN2,4)
Open or 5.5 ~ 10VDC power supply ON
Short or 0 ~ 0.8VDC power supply OFF
Input Fuse
There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each
model are shown as below.
Type Fuse Type Reference and Rating
B Time-Lag Conquer MST, 10A, 250V *5
C Time-Lag Conquer MST, 8A, 250V *3
D Time-Lag Conquer MST, 6.3A, 250V *2
Turn On
Turn Off
DDR-480B-24 DDR-480C-24 DDR-480D-24
Vo 30 Vo 30 Vo 30
25 25 25
20 20 20
15 15 15
10 10 10
5 5 5
16 . 5 16.8 33 33.6 65 67.2
0 Vin 0 Vin 0 Vin
15 16 17 18 19 20 31 33 34 35 36 37 65 66 67 68 69 70
Inrush Current
Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by MOSFETs to reduce power
consumption after accomplishing the start-up.
Hold-up Time
EN50155:2017 version- B/C/D type comply with S2 level (10ms) @ full load , please refer to the table and curves show
below for the hold up time specification.
DDR-480B-12 DDR-480B-24
100% 100%
90% 90%
80% 80%
70% 70%
LOAD
LOAD
60% 60%
50% 50%
40% 40%
30% 30%
20% 20%
10% 10%
0% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms 140ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms
LOAD
60% 60%
50% 50%
40% 40%
30% 30%
20% 20%
10% 10%
0% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms 140ms 150ms 160ms
DDR-480C-24 DDR-480C-48
100% 100%
90% 90%
80% 80%
70% 70%
LOAD
LOAD
60% 60%
50% 50%
40% 40%
30% 30%
20% 20%
10% 10%
0% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms
DDR-480D-12 DDR-480D-24
100% 100%
90% 90%
80% 80%
70% 70%
LOAD
LOAD
60% 60%
50% 50%
40% 40%
30% 30%
20% 20%
10% 10%
0% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 12 0ms 130ms 140ms 150ms 160ms 170ms 180ms 190ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms 140ms 150ms 160ms
DDR-480D-48
100%
90%
80%
70%
LOAD
60%
50%
40%
30%
20%
10%
0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms 140ms 150ms 160ms
TIME figure 9
DDR-480B-12 DDR-480B-24
95% 95%
EFFICIENCY
EFFICIENCY
90% 90%
70% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD LOAD
DDR-480B-48 DDR-480C-12
95% 95%
EFFICIENCY
EFFICIENCY
90% 90%
70% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD LOAD
DDR-480C-24 DDR-480C-48
95%
95%
90%
90%
EFFICIENCY
EFFICIENCY
70% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD LOAD
DDR-480D-12 DDR-480D-24
95% 95%
EFFICIENCY
EFFICIENCY
90% 90%
75% 75%
70% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD LOAD
95%
DDR-480D-48
90%
EFFICIENCY
85% 154Vdc
110Vdc
80%
67.2Vdc
75%
70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
Cooling Test EN 50155 section 12.2.3 (Column 2, Class TX) Temperature: -40℃ No damage
EN 60068-2-1 Dwell Time: 2 hrs/cycle
Temperature: 19℃
EN 50155 section 12.2.11 Humidity: 65%
Increased Vibration Test PASS
EN 61373 Duration: 5 hrs
Temperature: 21± 3℃
Shock Test
EN 50155 section 12.2.11 Humidity: 65 ± 5% PASS
EN 61373 Duration: 30ms*18
EN 45545-2:2013
Oxygen index test PASS PASS PASS
EN ISO 4589-2:1996
EN 45545-2:2013
R22 Smoke density test PASS PASS PASS
EN ISO 5659-2:2006
EN 45545-2:2013
Smoke toxicity test PASS PASS PASS
NF X70-100:2006
EN 45545-2:2013
R24 Oxygen index test PASS PASS PASS
EN ISO 4589-2:1996
EN 45545-2:2013
R25 Glow-wire test PASS PASS PASS
EN 60695-2-11:2000
EN 45545-2:2013
R26 Vertical flame test PASS PASS PASS
EN 60695-11:2003
Mechanical Specification
Case No. 984F Unit:mm
1234 5678
TB2
36
DC OK
DC OK
Vo Adj. +
125.2
1 2 3 4
TB1
85.5
Bottom View