240W DIN Rail Type DC-DC Converter: Series
240W DIN Rail Type DC-DC Converter: Series
240W DIN Rail Type DC-DC Converter: Series
■ Features ■ Applications
Compliance to EN50155 and EN45545-2 railway standard Bus,tram,metro or railway system
Width only 40mm Industrial control system
2:1 wide input range Semi-conductor fabrication equipment
-40~+70℃ wide working temperature Factory automation
150% peak load capability Electro-mechanical
Current sharing up to 960W(3+1) Wireless network
DC output adjustable Telecom or datacom system
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Protections: Short circuit / Overload / Over voltage /
Over temperature / Input reverse polarity/
Input under voltage protection
4KVdc I/O isolation(Reinforced isolation)
DC OK relay contact
Remote ON-OFF control
3 years warranty
■ Description
DDR-240 series is a 240W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation,
ultra slim width (40mm), 2:1 wide input voltage, fanless design, -40~+70℃ wide operating temperature, 4KVdc
I/O isolation, 150% peak load, current sharing,DC OK, adjustable output voltage and full protective functions.
This series of models has various input options: 16.8~33.6V / 33.6~67.2V / 67.2~154V and two output options:
24V / 48V and can be used for industrial & railway control, security control, communication system and other fields.
Suitable applications include to DC buck/boost regulator, increasing system insulation level and voltage drop
compensation along cable...etc.
■ Model Encoding
DDR - 240 B - 24
Output voltage(24/48Vdc)
Input voltage (B:16.8~33.6Vdc, C:33.6~67.2Vdc, D:67.2~154Vdc)
Rated wattage
Series name
DC OK
FG DETECTION
PWM CIRCUIT
O.L.P. CONTROL
O.V.P.
Remote
ON/OFF Control CURRENT P+
SHARE P-
100
90
150
80 C/D Type
For 3 sec. (typ.)
120
70 B Type
100
LOAD (%)
LOAD (%)
60
Continuous
50
40
40
Peak Loading
(1) (2)
360W 360W
(150% load) (150% load)
240W 120W
(100% load) 100 sec. 3 sec. (50% load) 10 sec. 3 sec.
DC OK Relay Contact
Function Manual
1. Current sharing
(1) Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel) :
(2) The voltage difference among each output should be minimized that less than 0.2V is required.
(3) The total output current must not exceed the value determined by the following equation (Output current at parallel operation)
=(The rated current per unit) x (Number of unit) x 0.9.
(4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications.
(5) When in parallel operation, the minimum output load should be greater than 3% of total output load.
(Min. load > 3% rated current per unit x number of unit)
+ LOAD -
+V DC OK +V DC OK +V DC OK +V DC OK
-V P- P+ -V P- P+ -V P- P+ -V P- P+
+ + + +
Vo Adj. Vo Adj. Vo Adj. Vo Adj.
DC OK DC OK DC OK DC OK
Remote ON-OFF
Output Status
(TB1 PIN2,4)
Open or 4 ~ 10VDC power supply ON
Short or 0 ~ 0.8VDC power supply OFF
Input Fuse
There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each
model are shown as below.
Type Fuse Type Reference and Rating
B Time-Lag Conquer MST, 10A, 250V *2
C Time-Lag Conquer MST, 6.3A, 250V *2
D Time-Lag Conquer MST, 6.3A, 250V *1
DDR-240B-24 DDR-240C-24
Vo 30 Vo 30
25 25
20 20
15 Turn On 15 Turn On
Turn Off Turn Off
10 10
5 5
16 . 5 16.8 33.6
0 Vin 0 Vin
15 16 17 18 19 20 31 33 34 35 36 37
DDR-240D-24
Vo 30
25
20
15 Turn On
Turn Off
10
5
65 67.2
0 Vin
65 66 67 68 69 70
Inrush Current
Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power
consumption after accomplishing the start-up.
Hold-up Time
EN50155: 2007 version - B/C- type comply with S2 level (10ms)@ 70% load ; D-type comply with S2 level (10ms)@ full load ,
P l ease r efer to th e table and cu r ves show below for the hold u p t i me specification .
DDR-240B-24 DDR-240B-48
100% 100%
90% 90%
80% 80%
70% 70%
LOAD
LOAD
60% 60%
50% 50%
40% 40%
30% 30%
20% 20%
10% 10%
0% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms
TIME TIME
(figure 1) (figure 2)
DDR-240C-24 DDR-240C-48
100% 100%
90% 90%
80% 80%
70% 70%
LOAD
LOAD
60% 60%
50% 50%
40% 40%
30% 30%
20% 20%
10% 10%
0% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms
TIME TIME
(figure 3) (figure 4)
DDR-240D-24 DDR-240D-48
100% 100%
90% 90%
80% 80%
70% 70%
LOAD
LOAD
60% 60%
50% 50%
40% 40%
30% 30%
20% 20%
10% 10%
0% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms
TIME TIME
(figure 5) (figure 6)
DDR-240B-24 DDR-240B-48
94% 94%
92% 92%
EFFICIENCY
EFFICIENCY
90% 90%
88% 33.6Vdc 88% 33.6Vdc
86% 24Vdc 86% 24Vdc
84% 16.8Vdc 84% 16.8Vdc
82% 82%
80% 80%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD LOAD
DDR-240C-24 DDR-240C-48
95% 95%
EFFICIENCY
EFFICIENCY
90% 90%
70% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD LOAD
DDR-240D-24 DDR-240D-48
95% 95%
EFFICIENCY
EFFICIENCY
90% 90%
85%
154V dc 85% 154V dc
80% 110V dc 110V dc
80%
75% 67.2V dc 67.2V dc
70% 75%
65% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD LOAD
Cooling Test EN 50155 section 12.2.3 (Column 2, Class TX) Temperature: -40℃ No damage
EN 60068-2-1 Dwell Time: 2 hrs/cycle
Temperature: 19℃
EN 50155 section 12.2.11 Humidity: 65%
Increased Vibration Test PASS
EN 61373 Duration: 5 hrs
Temperature: 21± 3℃
Shock Test
EN 50155 section 12.2.11 Humidity: 65 ± 5% PASS
EN 61373 Duration: 30ms*18
EN 45545-2:2013
Oxygen index test PASS PASS PASS
EN ISO 4589-2:1996
EN 45545-2:2013
R22 Smoke density test PASS PASS PASS
EN ISO 5659-2:2006
EN 45545-2:2013
Smoke toxicity test PASS PASS PASS
NF X70-100:2006
EN 45545-2:2013
R24 Oxygen index test PASS PASS PASS
EN ISO 4589-2:1996
EN 45545-2:2013
R25 Glow-wire test PASS PASS PASS
EN 60695-2-11:2000
EN 45545-2:2013
R26 Vertical flame test PASS PASS PASS
EN 60695-11:2003
Mechanical Specification
Case No.265A-D Unit:mm
TB2
Vo Adj. +
TB3
DC OK
125.2
TB1
1 2 3 4
Bottom View
Installation Instruction
Back View
Installation Manual
Please refer to : http://www.meanwell.com/manual.html