75W Constant Power Mode LED Driver XLG-75 series

110 M M
SELV Type HL
Note.12

■ Features ■ Applications
•Wide input range 100~305V AC( ClassⅠ) •Skyscraper lighting
•Full power output at 70~100% Constant power mode operation •Street lighting
•Metal case with IP67, suitable for outdoor application •Floodlight Lighting
•LVLE and Class 2 power unit(except for L type) •Stage lighting
•Surge protection with 6K V/4K V (10K V/6K V optional) •Fishing lighting
•3 in 1 dimming function (Dim to off and Isolation design) •Horticulturelighting
•India (EESL) version with Input Over Voltage Protection can •Bay lighting
survive input voltage stress of 440Vac for 48 hours •DMXpowersupply
•Protection functions: OVP/SCP/OCP/OTP •Type HL for use in classⅠ, Division 2
•Life time >50,000 hrs. and 5 years warranty
■ Description
XLG-75 series is a 75W LED AC/DC driver featuring the constant power mode. XLG-75 operates from
100~305VAC and offers models with different rated current ranging between 700mA and 5000mA.
Thanks to the high efficiency up to 91% , with the fanless design, the entire series is able to operate for
-40℃~+90℃ case temperature under free air convection. The design of metal housing and IP67 ingress
protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative
environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application
environments in almost any spots that may install LED luminaires in the world. XLG-75 series comply
with the latest version of IEC61347/GB7000.1-2015 and UL8750 international safety regulations. The
output and dimming circuit are also completely in accordance with the new regulations with isolation to
ensure the safety of both user and luminaire system during installation.

■ Model Encoding
XLG - 75 I - L -

Function options
Rated output voltage(12/24V or L/H types)


I: for India version
:For standard version
Rated wattage
Series name
Type Function Note
Blank Io and Vo fixed.(For harsh envirenment) By request
A Io adjustable via built-in potentiometer In Stock
Io adjustable via built-in potentiometer +
AB In Stock
3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance)
Note: 12V and 24V models without the AB type
File Name:XLG-75-SPEC 2019-04-09
75W Constant Power Mode LED Driver XLG-75 series
SPECIFICATION
MODEL XLG-75-12- XLG-75-24-
DC VOLTAGE 12V 24V
CONSTANT CURRENT REGION Note.2 8.4~ 12V 16.8~ 24V
RATED CURRENT 5A 3.1A
RATED POWER 60W 74.4W
RIPPLE & NOISE (max.) Note.3 150mVp-p 240mVp-p
CURRENT ADJ RANGE 2.5A~5A 1.55A~3.1A
OUTPUT VOLTAGE TOLERANCE Note.4 ±3.0% ±2.0%
LINE REGULATION ±0.5% ±0.5%
LOAD REGULATION ±2% ±1%
SETUP, RISE TIME Note.6 500ms, 100ms/230VAC, 1200ms, 100ms/115VAC
HOLD UP TIME (Typ.) 10ms/ 230VAC 10ms/ 115VAC
100 ~ 305VAC 142 ~ 431VDC
VOLTAGE RANGE Note.5
(Please refer to "STATIC CHARACTERISTIC" section)
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
TOTAL HARMONIC DISTORTION THD< 10%(@load≧50%/115VC,230VAC; @load≧75%/277VAC)
INPUT EFFICIENCY (Typ.) 89% 90%
AC CURRENT 1.0A / 115VAC 0.45A / 230VAC 0.38A/277VAC
INRUSH CURRENT(Typ.) COLD START 50A(twidth=300μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A
9 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
CIRCUIT BREAKER
LEAKAGE CURRENT <0.75mA / 277VAC
NO LOAD No load power consumption <0.5W(for standard version)
POWER CONSUMPTION
95 ~ 108%
OVER CURRENT
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
PROTECTION 13 ~ 19V 26 ~ 36V
OVER VOLTAGE
Shut down output voltage, re-power on to recover
320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage)
INPUT OVER VOLTAGE Note.7
can survive input voltage stress of 440Vac for 48 hours
OVER TEMPERATURE Shut down output voltage, re-power on to recover
WORKING TEMP. Tcase=-40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP. Tcase=+90℃
WORKING HUMIDITY 20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +90℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 60℃)
VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750(type”HL”), UL879, CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384;
SAFETY STANDARDS
GB19510.1,GB19510.14; EAC TP TC 004; IP67 approved
WITHSTAND VOLTAGE I/P-O/P:4.2KVAC I/P-FG:2.1KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter Standard Test Level/Note
Conducted EN55015(CISPR15) -----
EMC EMISSION Radiated EN55015(CISPR15) -----
Harmonic Current EN61000-3-2 Class C @load≥50%
EMC Voltage Flicker EN61000-3-3 -----
SAFETY & EN61547
Parameter Standard Test Level/Note
ESD EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated EN61000-4-3 Level 3
EMC IMMUNITY EFT/Burst EN61000-4-4 Level 3
Surge EN61000-4-5 4KV/Line-Line 6KV/Line-Earth(6K/10K option)
Conducted EN61000-4-6 Level 3
Magnetic Field EN61000-4-8 Level 4

Voltage Dips and Interruptions EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
MTBF 1232.28K hrs min. Telcordia SR-332 (Bellcore) ; 376.3Khrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 140*63*32mm (L*W*H)
PACKING 0.58Kg;24pcs /15Kg /0.85CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. Only for XLG-75 I series
8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
12.Products sourced from the Americas regions may not have the PSE/CCC/BIS/KC logo. Please contact your MEAN WELL sales for more information.
13.For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
File Name:XLG-75-SPEC 2019-04-09
75W Constant Power Mode LED Driver XLG-75 series
SPECIFICATION
MODEL XLG-75-L- XLG-75-H-
RATED CURRENT 700mA 1400mA
RATED POWER 75W 75W
CONSTANT CURRENT REGION 53 ~ 107V 27 ~ 56V
FULL POWER CURRENT RANGE 700~1050mA 1300~2100mA
OUTPUT OPEN CIRCUIT VOLTAGE (max.) 115V 60V
CURRENT ADJ. RANGE 350~1050mA 650~2100mA
CURRENT RIPPLE 3.0%(@rated current)
CURRENT TOLERANCE ±5%
SET UP TIME 500ms/230VAC, 1200ms/115VAC
100 ~ 305VAC 142VDC ~ 431VDC
VOLTAGE RANGE Note.5
(Please refer to "STATIC CHARACTERISTIC" ang “ DRIVING METHODS OF LED MODULE"section)
FREQUENCY RANGE 47 ~ 63Hz
PF≧0.97 / 115VAC, PF≧0.95 / 230VAC, PF≧0.92 / 277VAC at full load
POWER FACTOR (Typ.)
(Please refer to "Power Factor Characteristic" section)
THD< 10% (@ load≧50% at 115VAC/230VAC ,@load≧75% at 277VAC)
TOTAL HARMONIC DISTORTION
Please refer to “TOTAL HARMONIC DISTORTION (THD)” section
INPUT EFFICIENCY (Typ.) 91% 90%
AC CURRENT (Typ.) 1A / 115VAC 0.45A / 230VAC 0.38A / 277VAC
INRUSH CURRENT(Typ.) COLD START 50A(twidth=300μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. NO. of PSUs on 16A
9 unit(circuit breaker of type B) / 14 units(circuit breaker of type C) at 230VAC
CIRCUIT BREAKER
LEAKAGE CURRENT <0.75mA / 277VAC
STANDBY
Standby power consumption <0.5W for AB-Type(Dimming OFF)(for standard version)
POWER CONSUMPTION
110 ~ 150%
OVER POWER
Hiccup mode, recovers automatically after fault condition is removed
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
PROTECTION SHORT CIRCUIT
320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage)
INPUT OVER VOLTAGE Note.7
can survive input voltage stress of 440Vac for 48 hours
OVER TEMPERATURE Shut down output voltage, re-power on to recovery
WORKING TEMP. Tcase=-40 ~ +90℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
MAX. CASE TEMP. Tcase=+90℃
WORKING HUMIDITY 20 ~ 95% RH non-condensing
ENVIRONMENT
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 60℃)
VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750(type”HL”), UL879, CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384;
SAFETY STANDARDS
GB19510.1,GB19510.14; EAC TP TC 004; IP67 approved
WITHSTAND VOLTAGE I/P-O/P:4.2KVAC I/P-FG:2.1KVAC O/P-FG:1.5KVAC
SAFETY &
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC
Parameter Standard Test Level/Note
Conducted EN55015(CISPR15) -----
EMC EMISSION Radiated EN55015(CISPR15) -----
Harmonic Current EN61000-3-2 Class C @load≥50%
Voltage Flicker EN61000-3-3 -----
EN61547
Parameter Standard Test Level/Note
ESD EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated EN61000-4-3 Level 3
EMC IMMUNITY EFT/Burst EN61000-4-4 Level 3
Surge EN61000-4-5 4KV/Line-Line 6KV/Line-Earth(6K/10K option)
Conducted EN61000-4-6 Level 3
Magnetic Field EN61000-4-8 Level 4

Voltage Dips and Interruptions EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
MTBF 1232.28K hrs min. Telcordia SR-332 (Bellcore) ; 376.3Khrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 140*63*32mm (L*W*H)
PACKING 0.58Kg;24pcs /15Kg /0.85CUFT

NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7.Only for XLG-75 I series
8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
12.Products sourced from the Americas regions may not have the PSE/CCC/BIS/KC logo. Please contact your MEAN WELL sales for more information.
13.To fullfill requirements of the latest ErP regulation for lighting fixtures, this LED drivers can only be used behind a switch without permanently connected
to the mains
14.For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
File Name:XLG-75-SPEC 2019-04-09
75W Constant Power Mode LED Driver XLG-75 series

BLOCK DIAGRAM
PFC fosc : 50~120KHz
PWM fosc : 65KHz

EMI FILTER PFC POWER RECTIFIERS +V


I/P & SWITCHING & -V
CIRCUIT
RECTIFIERS FILTER
O.C.P. DIM+
DIM-

(AB Type)
FG O.L.P. DETECTION
PFC PWM CIRCUIT
CONTROL CONTROL
O.T.P.
O.V.P.
(12/24V)

DRIVING METHODS OF LED MODULE

※ I-V Operating Area

◎ XLG-75-L ◎ XLG-75-H

60V
115V
650mA, 56V 1300mA, 56V
350mA, 107V 700mA, 107V 55V
105V
50V
95V
45V
85V 40V 2100mA, 36V
1050mA, 71V
75V 35V

65V 30V

55V 25V
700mA, 53V 1050mA, 53V
1300mA, 27V 2100mA, 27V
45V 20V
0mA 200mA 400mA 600mA 800mA 1000mA 1200mA 0mA 350mA 700mA 1050mA 1400mA 1750mA 2100mA

Recommend Performance Region Recommend Performance Region

◎ XLG-75-12,24

※ This series is able to work in either Constant Current mode (a


direct drive way) or Constant Voltage mode (usually through
additional DC/DC driver) to drive the LEDs.

100
In the constant current
(B) region, the highest voltage
Vo(%)

(A) Constant at the output of the driver


Constant Current area
Voltage area
depends on the configuration
60 of the end systems.
(min.) Should there be any
(C) compatibility issues, please
Hiccup
Protection please contact MEAN WELL.

50 100 Io(%)

Typical output current normalized by rated current (%)

File Name:XLG-75-SPEC 2019-04-09


75W Constant Power Mode LED Driver XLG-75 series

DIMMING OPERATION

AC/N(Blue) Vo-(Black)
Vo+(Red)
AC/L(Brown) XLG-75 DIM+( Blue )
FG(Green/Yellow) DIM-(White)

※ 3 in 1 dimming function (for AB-Type)


•Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:
0 ~ 10VDC, or 10V PWM signal or resistance.
•Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
•Dimming source current from power supply: 100μA (typ.)
◎ Applying additive 0 ~ 10VDC 100%
90%
80%
+
Vo+ + 70%
Output current (%)

60%
-
Vo- - 50%
DIM+ 40%
+
30%
Additive Voltage
- 20%
DIM-
10%

“DO NOT connect "DIM- to Vo-" 0%


0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V
Dimming input: Additive voltage

◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): 100%
90%
80%
+
Vo+ + 70%
Output current (%)

60%
-
Vo- - 50%
DIM+ 40%

Additive PWM signal 30%


20%
DIM-
10%

“DO NOT connect "DIM- to Vo-" 0%


0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Duty cycle of additive 10V PWM signal dimming input

◎ Applying additive resistance: 100%


90%
+ 80%
Vo+ +
70%
Output current (%)

- 60%
Vo- -
DIM+ 50%
40%
Additive Resistance
30%
DIM- 20%
10%
“DO NOT connect "DIM- to Vo-"
0%
Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N
(N=driver quantity for synchronized dimmingoperation)
Dimming input: Additive resistance
Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.
2. The output current could drop down to 0% when dimming input is about 0Ω or 0Vdc, or 10V PWM signal with 0% duty cycle.

File Name:XLG-75-SPEC 2019-04-09


75W Constant Power Mode LED Driver XLG-75 series

OUTPUT LOAD vs TEMPERATURE

230VAC
100 100

80 80
230VAC 230VAC
Input only 100VAC Input only
60 60
LOAD (%)

LOAD (%)
40 40

20 20

-40 -30 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -30 0 10 30 50 70 90 (HORIZONTAL)

AMBIENT TEMPERATURE,Ta (℃) Tcase (℃)

If XLG-75 operates in Constant Power mode with the rated


current the maximum workable Ta is 60℃ (Typ. 230VAC)

STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC


※ Tcase at 75℃

Constant Current Mode


100
1
90

80 0.95
PF

70
0.9
277V
LOAD (%)

60
0.85 230V

50 115V

0.8
40

0.75 (300W)
100 110 140 160 180 200 220 240 260 280 305 50% 60% 70% 80% 90% 100%

INPUT VOLTAGE (V) 60Hz LOAD

TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD


XLG-75 series possess superior working efficiency that up to 92% can
be reached in field applications.
※ XLG-75-L Model, Tcase at 75℃ ※ XLG-75-L Model, Tcase at 75℃

10%
96
9%
92
8%
EFFICIENCY(%)

88
7%
84
6% 277V
THD

277V
80
5% 230V 230V
76 115V
4% 115V
3% 72

2% 68

1% 64
0% 60
50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

LOAD LOAD

File Name:XLG-75-SPEC 2019-04-09


75W Constant Power Mode LED Driver XLG-75 series

LIFETIME

120

100

80
LIFETIME(Kh)

60

40

20

0
25 30 35 40 45 50 55 60 65 65 70 75 80 85 90

Tcase( )

File Name:XLG-75-SPEC 2019-04-09


75W Constant Power Mode LED Driver XLG-75 series

MECHANICAL SPECIFICATION Case No.: 275A Unit:mm

※ Blank-Type
140
134
300±20 125 300±20

40
63

AC/N(Blue) Vo-(Black)
AC/L(Brown) Vo+(Red)
FG(Green/Yellow) SJOW 17AWGx3C tc 57 2
2
SJOW 17AWGx2C &05RN-F 2x1.0mm
&H05RN-F 3x1.0mm

24
4-Φ4.5

• tc : Max. Case Temperature

32
Vo-(Black)
Vo+(Red)

Vo-(Black)
Vo+(Red)

※ A-Type
140
134
300±20 125 300±20
40
63

AC/N(Blue) Vo-(Black)
AC/L(Brown) Vo+(Red)
FG(Green/Yellow) SJOW 17AWGx3C tc 57 2
SJOW 17AWGx2C &05RN-F 2x1.0mm
&H05RN-F 3x1.0mm 2
24

4-Φ4.5

• tc : Max. Case Temperature


32

Vo-(Black)
Vo+(Red)

39.7
12.7

Vo-(Black)
Vo+(Red)

File Name:XLG-75-SPEC 2019-04-10


75W Constant Power Mode LED Driver XLG-75 series

MECHANICAL SPECIFICATION Case No.: 275A Unit:mm

※AB-Type

140
134
300±20 125 300±20

SJOW 17AWGx2C
&05RN-F 2x1.0mm 2
40
63

Vo-(Black)
AC/N(Blue) Vo+(Red)
AC/L(Brown) DIM+( Blue )
FG(Green/Yellow) SJOW 17AWGx3C tc 57 DIM-(White)

&H05RN-F 3x1.0mm 2 UL2517 20AWGx2C

24
4-Φ4.5 350±20

• tc : Max. Case Temperature

32
DIM+( Blue )
DIM-(White)

39.7
12.7

DIM-(White)
DIM+( Blue )
Vo+(Red)
Vo-(Black)

INSTALLATION MANUAL