DDR 120 Spec
DDR 120 Spec
DDR 120 Spec
User’s Manual
■ Features ■ Applications
Compliance to BS EN/EN50155 and BS EN/EN45545-2 Bus,tram,metro or railway system
railway standard Industrial control system
Width only 32mm Semi-conductor fabrication equipment
2:1 wide input range Factory automation
-40~+70℃ wide working temperature Electro-mechanical
150% peak load capability Wireless network
DC output adjustable Telecom or datacom system
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
■ GTIN CODE
Protections: Short circuit / Overload / Over voltage /
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Input reverse polarity / Input under voltage protection
4KVdc I/O isolation(Reinforced isolation)
3 years warranty
■ Description
DDR-120 series is a 120W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation,
ultra slim width (32mm), 2:1 wide input voltage, fanless design, -40~+70℃ wide operating temperature, 4KVdc
I/O isolation, 150% peak load, adjustable output voltage and full protective functions.
This series of models has various input options: 9~18V / 16.8~33.6V / 33.6~67.2V / 67.2~154V and various
output options: 12V / 24V / 48V and can be used for industrial & railway control, security control, communication
system and other fields. Suitable applications include DC buck/boost regulator, increasing system insulation level
and voltage drop compensation along cable...etc.
■ Model Encoding
DDR - 120 A - 24
Output voltage(12/24/48Vdc)
Input voltage (A: 9~18Vdc, B:16.8~33.6Vdc, C:33.6~67.2Vdc, D:67.2~154Vdc)
Rated wattage
Series name
Block Diagram
fosc : 65KHz
FG DETECTION
PWM CIRCUIT
O.L.P. CONTROL
O.V.P.
100
90
150 85
80 B/C/D Type
120 For 3 sec. (typ.)
70 A Type
100
LOAD (%)
LOAD (%)
80 60
Continuous
50
40
40
Peak Loading
(1) (2)
Input Fuse
There is a fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications
of each model are shown as below.
DDR-120A-24 DDR-120B-24
Vo 30 Vo 30
25 25
20 20
15 Turn On 15 Turn On
Turn Off Turn Off
10 10
5 5
8. 5 16 . 5 16.8
0 Vin 0 Vin
8 9 10 15 16 17 15 16 17 18 19 20
DDR-120C-24 DDR-120D-24
Vo 30 Vo 30
25 25
20 20
15 Turn On 15 Turn On
Turn Off Turn Off
10 10
5 5
33.6 65 67.2
0 Vin 0 Vin
31 33 34 35 36 37 65 66 67 68 69 70
The series has a wide range input capability. With -30% / +40% of rated input voltage(except A Type), it can withstand that for 1 second.
Inrush Current
Inrush current is suppressed by a current limit circuit during the initial start-up, and then the circuit is bypassed by a MOSFET to
reduce power consumption after accomplishing the start-up.
Power start
Normal current
Inrush current limit
Hold-up Time
EN50155: 2007 version - D type is in compliance with S2 level (10ms), while A types are in compliance with S1 level (3ms) at full load output
condition. To fulfil the requirements of S2 level (10ms), B types require de-rating their output load to 70%, C types
require de-rating their output load to 60%, please refer to the curve diagrams below.
LOAD
LOAD
60% 60% 60%
50% 50% 50%
40% 40% 40%
30% 30% 30%
20% 20% 20%
10% 10% 10%
0% 0% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms
LOAD
LOAD
60% 60% 60%
50% 50% 50%
40% 40% 40%
30% 30% 30%
20% 20% 20%
10% 10% 10%
0% 0% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms
LOAD
LOAD
LOAD
LOAD
The efficiency vs load & Vin curves of each model are shown as below.
EFFICIENCY
EFFICIENCY
90% 90% 90%
EFFICIENCY
EFFICIENCY
90% 90% 90%
EFFICIENCY
EFFICIENCY
EFFICIENCY
EFFICIENCY
Cooling Test EN 50155 section 12.2.3 (Column 2, Class TX) Temperature: -40℃ No damage
EN 60068-2-1 Dwell Time: 2 hrs/cycle
Temperature: 19℃
EN 50155 section 12.2.11 Humidity: 65%
Increased Vibration Test PASS
EN 61373 Duration: 5 hrs
Temperature: 21± 3℃
Shock Test
EN 50155 section 12.2.11 Humidity: 65 ± 5% PASS
EN 61373 Duration: 30ms*18
EN 45545-2:2013
Oxygen index test PASS PASS PASS
EN ISO 4589-2:1996
EN 45545-2:2013
R22 Smoke density test PASS PASS PASS
EN ISO 5659-2:2006
EN 45545-2:2013
Smoke toxicity test PASS PASS PASS
NF X70-100:2006
EN 45545-2:2013
R24 Oxygen index test PASS PASS PASS
EN ISO 4589-2:1996
EN 45545-2:2013
R25 Glow-wire test PASS PASS PASS
EN 60695-2-11:2000
EN 45545-2:2013
R26 Vertical flame test PASS PASS PASS
EN 60695-11:2003
Mechanical Specification
Case No. Unit:mm
32
102
TB2
1234
(No Use)
+Vo
Adj.
125.2
123
TB1
Side View Front View Side View
2 DC Input -Vin
3 DC Input +Vin
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
Bottom View
Installation Manual