User’s manual
Control unit for compressors
SERIE / SERIES
- DNAir1
Emissione/Issue: 06/2015
Revisione/Revision: 1
Data revisione/Revision date 17/07/2015
File: Manuale Centralina DNAir1_ITA_R1
Tasto su
1
Up button
Tasto giù
2
Down button
Tasto menù (Enter)
3
Menù button (Enter)
Tasto Start/Stop
4
Start/Stop button
Tasto Esc/Reset
5
Esc/Reset button
A Display Lcd
Figura 1 / Figure 1
General features:
Power supply 12Vac ±10%
Max consumption at 12Vac 200mA
Relay outputs 5
Transistor outputs 1 12Vdc max 100mA
Relay maximum current 5 A resis. Max 24Vac
Serial standard RS232* 1
Serial standard RS485* Preset unmounted
Digital inputs 8
Phase sequence input 1 to 5 Vac
Temp. analog input 1 (12 bit)
LCD contrast adjustment 60 levels
Maximum lifespan 65,000 hours
Analog input 4-20mA 1 (12 bit)
Analog output 4-20mA 1 (10 bit)
Boot loader you can update the Firmware via RS232.
HOME PAGE: remains displayed for 2 seconds after turning on the control unit.
EasyMicro III
V.0.0.0 00/00/00
Press the buttons 1 and 2 to scroll through the different options, the information will be displayed for 15 seconds.
ALARMS:
1) Rotation direction; in case of incorrect phase sequence, alarm signal is given. The alarm blocks
the compressor, to restore operation, restore the phase sequence. When the internal phase
sequence is enabled, the same is controlled only for the first 30 seconds after the ignition of the
controller; the incorrect sequence must last at least 10 seconds.
CAUTION: This alarm can only be reset by cutting off the power supply
2) Temperature probe: is controlled by the temperature sensor (open or shorted probe) installed.
The alarm signal is given. The alarm locks the compressor, to restore the operation check the
probe and press the button 8.
110 h00001 m00
temp.sens.faulty
3) Maximum oil temperature: when maximum oil temperature is reached, the alarm is triggered.
This alarm locks the compressor. To restart the compressor, you need to wait for the temperature
to drop below the set value and press the button 8.
4) Minimum oil temperature: when the minimum oil temperature is reached, the alarm is triggered.
This alarm locks the compressor. To restart the compressor, you need to wait for the temperature
to rise above the set value and press the button 8.
5) Oil temperature pre-alarm: when the oil pre-alarm temperature is reached, the alarm is
triggered. The alarm does not lock the compressor. To reset the alarm, press the button 8.
105°C h00001 m00
Oil temp. pre.
6) Motor thermal switches: when the motor or fan thermal switch is triggered, the alarm is
activated. This alarm locks the compressor. To reset the alarm press key 8 after having checked
the cause; if the cause is parameter 17 and every thermal breaker is triggered, 2 types of alarms
will be activated
Motor thermal switch and Fan thermal switch: according to the input which is activated by the
thermal switch.
9) Pressure sensor broken: this alarm is activated when the pressure sensor connected to the
input 4-20mA is not working properly. : this alarm locks the compressor. To reset the alarm press
key 8 Reset, after having restored the normal state of the pressure sensor.
105°C h00001 m00
Press.Sens.Broken
10) Maximum pressure reached: this alarm is activated when the maximum pressure set for the
maximum pressure alarm parameter is exceeded; this alarm locks the compressor. To reset the
alarm press key 8, after having restored the correct value of the pressure.
105°C h00001 m00
Max. pressure
11) Inverter Faulty: the alarm is triggered when the external phase sequence inverter is active
turning into inverter faulty signal; it is active only after 20 seconds after controller ignition. It can be
deactivated via the internal phase control menu; the faulty inverter control is deactivated and the
external phase sensor is restored.
This alarm can also be triggered by the I/O (COMP09) circuit board.
105°C h00001 m00
Inverter Fault
12) Dryer alarm: This alarm is triggered when the dryer parameter is active and the dryer alarm input
is high; the alarm does not block the compressor.
13) Remote pressure alarm: This alarm is triggered when the remote pressure is active and the
pressure reaches the set vacuum value.
If there are multiple consecutive alarms, the same will be displayed in sequence and by pressing the 5
key you can reset all alarms for which the cause was restored.
1st alarm
0)95°C h1 m0
Motor Thermal
5th alarm
5)40°C h1864 m56
Emergency button
Input Activation
• Motor thermal switch: Always active.
• Rotation direction: Always active except for the case in which you turn on the inverter of the
parameter or the internal phase sequence parameter is ON.
• Remote ON/OFF: Always active except for the case in which the active remote pressure turns into
remote pressure input
• Emergency: Always active.
• Work pressure switch: Active only when the electronic pressure sensor is disabled.
• 4-20mA in: Input active only if the electronic pressure switch is enabled
• Temperature probe: Always active.
• +5V phase sequence transformer: Active only if the internal phase sequence is enabled
Output activation
• Line remote control switch: active during start-up
• Star remote control switch: active during start-up
• Triangle remote control switch: active after 5 seconds from start-up
• Load solenoid valve: active after 3 seconds after switching to triangle (with inverter the time is
variable)
• Fan: active only when the motor is running and after having exceeded the set temperature
• 4-20mA out: active only with the inverter active.
• AUX output: active when an alarm is triggered
Settable parameters:
Unit of
Parameter MIN MAX TYP Measure Password
ID
ment
Parameters Menu
Press the key OK with the machine at a standstill (Status = OFF) to access the parameters menu:
1) Pre-alarm time: Menu of service hours, these meters are calibrated automatically after each hour of
operation of the machine, when the meter reaches the value 0, the controller sends the maintenance
alert, there are 4 meters
-Oil Hours
-Oil Filter Hours
-Air Filter Hours
-Oil Separator Hours
The meter with the sign – in front indicates the hours passed from the maintenance alert; use the keys 1
or 5 to set the new value desired; press the key 4 to set the meter to 2000 (to restore the maintenance
alarm set the greater value to 0).
2) Alarm history: Access to scroll through the last 100 alarms and read the working time and the
temperature of oil at which the alarm was triggered.
3) Fan temperature: this parameter is the fan enabling temperature; the adjustment range is from 0 to 150
°C, at a preset temperature the fan starts, the hys teresis is fixed at 10 °C.
4) No load time: in this parameter you can change the no load cycle time of the machine, the adjustment
range is from 30 to 250 seconds.
5) Automatic Start: The parameter enables the automatic start, when this parameter is activated the
compressor starts automatically, even after a power outage; the first start can be enabled by pressing
the key 4 on the keyboard. For safety reasons we strongly advise you NOT to use it.
6) Int. phase sequence: The parameter enables the internal phase sequence control.
8) Stop time: It defines the delay of compressor shutdown from the moment in which stop is requested via
the key START/STOP. The solenoid valve is turned off immediately.
9) Fan extra time: It defines the time within which the fan remains active after the temperature returns within the
safety limits.
10) Separate thermal switches: Indicate whether the motor and fan thermal switches are separate, or if they are
together. If they are separated, the alarms will be separated as well.
11) PTC enabled: If set to ON, the input is prepared to accept the PTC in input with triggering threshold at about
2Khom; check the wiring diagram.
12) PSI/BAR/KPa: In this parameter the user can choose the unit of measurement for the pressure.
14) Operating pressure/vacuum setting: in this parameter you can enter the operating pressure at which
the compressor stop; if the inverter is active, this parameter indicates the operating pressure at which
the inverter must begin to modulate to keep it steady.
15) Operation delta/load setting: indicates the pressure at which the controller enables the compressor
restart. If the inverter is active, this parameter becomes the delta of operation, i.e. , it indicates the range
of pressure at which the compressor has to work for example, if set to 1.0 bar and the operating
pressure is 9.0 bar, it means that the compressor will shut down to 9.5 bar and will restarts at 8.5 bar.
16)Remote pressure: By enabling this parameter, you will maintain the pressure display and the associated
alarms, but compressor restart is controlled via remote pressure switch contact, the remote on/off
input is disabled. If the pressure measured by the internal electronic transducer exceeds the set
pressure, the compressor stops, even if the external pressure switch prompts you to continue.
19) Load delay: this parameter is only active in the presence of the INVERTER; you can set the delay in
seconds, from the moment in which the start-up cycle ends to the moment in which you activate the air
load solenoid valve.
20) Supplementary inverter: Parameter that changes the complementary constant of inverter speed
calculation.
21) Proportional inverter: Parameter that changes the proportional constant on the calculation of inverter
speed; by raising this parameter you can track the speed more responsively.
22) Derivative inverter: Parameter that changes the derivative constant; by raising this parameter you will
have an estimate and a correction of the anticipated speed.
Password:
Support service password = 2954
Temperature
sensor
Pressure sensor
4/20mA
Fan relay
Star relay
Triangle relay
SV relay
Motor relay
Common relay
MOTOR PTC
TRIGGERED AT ABOUT 20KOhm (if the PTC is
used, set the PTC input parameter to ON)
R1
N DESCRIZIONE MODIFICA DESCRIPTION OF MODIFICATION Data/Date
0 Creazione (tutte le pagine) Created on (all pages) 17/06/2015
1 Modificata tabella parametri settabili (pag. 6) Settable parameters Table edited (page 6) 17/07/2015
Questa pubblicazione annulla e sostituisce ogni precedente edizione This publication replaces and supersedes any previous issue and
o revisione. La FINI NUAIR si riserva il diritto di apportare modifiche revision. FINI NUAIR reserves the right to implement modifications
senza preavviso. E' vietata la riproduzione anche parziale senza without notice. This manual cannot be reproduced, even partially,
specifica autorizzazione. without prior written consent.