1639-U-005 - R06 Datasheet Latest Datasheet

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 4

Korus Engineering Solutions Pvt. Ltd. Jindal Urban Waste Management (Guntur) Ltd.

Annexure - I : TECHNICAL DATA SHEET FOR COOLING WATER CIRCULATING PUMPS & OTHER PUMPS (UPDATED FOR SUBMERSIBEL PUMP SPEED) R5

Sl.No. Description Units


DW Water Tranfer Leachate Transfer
Raw Water Pumps N.Pit To LTP Pumps Cooling Water Pumps
Pumps Pumps
A General
Submersible Sump Pump
Submersible Sump Pump
with all accessories like
with all accessories like
Non Clog Self Priming/Assisted priming guide,chain,cable and
guide,chain,cable and
by vaccume pump /Horizontal Pump Control panel. Pit depth is
Type Horizontal Back Pull Out Horizontal Split Casing, Panel. Discharge hose
with Motor. Monoblock is not 3 meter. Discharge Piping
from pump discharge
acceptable. fixed in the pit and upto
flange to top of pit. Pit
top level with Auto Settler
depth approx 10 meter.
Coupling.
Qty Nos. 1W+1S 1W+1S 1W+1S 1W+1S 1W+1S
Type of flow Raw Water DW water Netulralised Waste Water Industrial water Leachate

Flow m3/h 60 30 10 300 10


Head (TDH) mWc 25 45 15 40 30
Tempurature of Feed Water °C 40 32 40 40 40
Suction Level mWc 3 meter suction lift (max.) Flooded Suction Flooded Suction Flooded Suction NA
Speed RPM 1500/3000 ( Single stage) 1500/3000 (Single Stage) 1500/3000 1500 1500/3000

Minimum Water Level M NA NA NA NA NA


Maximum Water Level M NA NA 0 NA 0
Pump/Motor Floor Level M 0 0 0 0 0
Type of Impeller Non clog design Closed impeller Non clog design Closed Non clog design
Suspended solids allowed up to 50 mm NA up to 50 mm NA up to 50 mm
B Site Data
Location Guntur (Andhra Pradesh) Guntur (Andhra Pradesh) Guntur (Andhra Pradesh) Guntur (Andhra Pradesh) Guntur (Andhra Pradesh)
Plant elevation (above MSL) m ~60 ~60 ~60 ~60 ~60
Seismic Zone Zone III As per IS:1893 Zone III As per IS:1893 Zone III As per IS:1893 Zone III As per IS:1893 Zone III As per IS:1893
Ambient temperature
For performance guarantee 0
C 35 35 35 35 35
For electrical design 0
C 50 50 50 50 50
Average high temperature 0
C 43 43 43 43 43
Average low temperature 0
C 17 17 17 17 17
C Pump Data (To Be Filled By Supplier)
Model/Size
Pump Type
Design Fluid Temperature °C
Rated Flow Cu.m/h
Rated Head m
NPSH required (at strainer inlet) m
Efficiency
BKW kw

TS No 1639-U-005 R0 TECHNICAL DATA SHEET Page 1 of 4


Annexure - I : TECHNICAL DATA SHEET FOR COOLING WATER CIRCULATING PUMPS & OTHER PUMPS (UPDATED FOR SUBMERSIBEL PUMP SPEED) R5

Sl.No. Range of OperationDescription Units


%
Recommended Motor KW/ speed KW
Impeller Diameter mm
Pump shut off head m
Pressure drop across strainer at full flow
condition and 50% clogged condition mWc
Suction/Discharge Size mm
D Electrical
Power Consumption at rated parameters kW
Motor Driver Rating kW
Voltage V
Frequency Hz
Combined Variation %
Motor shall be IE3 ( High efficiency Motor)
E Major codes
Design
Pumps IS-6595:1993-Part2 IS-6595:1993-Part2 IS-6595:1993-Part2
Material
Piping Components
Electrical motors
F Material
Impeller A743 CF8M A743 CF8M A743 CF8M A743 CF8M Supplier to provide as per
Suction casing Cast iron, Grade FG200 of IS 210 A743 CF8M Cast iron, Grade FG200 of Cast iron, Grade FG200 of suitability. Pump must be
IS 210 IS 210 suitable for sewerage
Discharge casing Cast iron, Grade FG200 of IS 210 A743 CF8M Cast iron, Grade FG200 of Cast iron, Grade FG200 of water quality
IS 210 IS 210
Shaft SS410 SS410 SS410 SS410
Shaft Sleeve SS410 (H) SS410 (H) SS410 (H) SS410 (H)
Base plate MS MS MS MS
Flange & Counter Flanges ASME B16.5 Class 150 ASME B16.5 ASME B16.5 ASME B16.5
G Equipment Weights
Weight of Pump with Base Frame & Motor kg

TS No 1639-U-005 R0 TECHNICAL DATA SHEET Page 2 of 4


Korus Engineering Solutions Pvt. Ltd Jindal Urban Waste Management (Guntur) Ltd.

Annexure - II : PERFORMANCE GUARANTEE - COOLING WATER CIRCULATING PUMPS P1 & P2


Sl.No. Description Units Input Value by Korus Remarks
Pump P1 for RO Pump P2 for DM Pump P3 for STP
P4 for Drain Pit P5 for Leachate
water water water
1 Pump flow M3/hr
2 Pump head MWC
3 Efficiency of the pump %
4 Power consumption KW

TS No 1638-U-005 R0 Performance Table Page 3 of 4


Korus Engineering Solutions Pvt. Ltd. Jindal Urban Waste Management (Guntur) Ltd.

ANNEXURE - III : SCOPE MATRIX FOR COOLING WATER CIRCULATING PUMPS P1&P2
( S - Supplier, P- Purchaser )
Supervision of
Mfg. &
Basic Detail erection &
S. No. Description Supply / Remarks
Engg. Engg. commissioning
Services
up to PG

Pumps
1 Pumps with complete assembly S S S S
2 Drive motors for the pumps S S S S

3 Coupling between Pump and Drive motor S S S S


Base Frame (Common For Pump+Motor) with
4 S S S S
foundation bolts

5 Matting flanges with fasteners at all terminal points S S S S

6 Commissioning Spares S S S S

7 Spares for 2 Years Operation S S S S

8 Maintenance Tools & Tackles-1 set for all pumps S S S S


9 Pressure gauges at suction and discharge S S S S

TS No. 1639-U-005 R0 SCOPE MATRIX Page 4 of 4