Approved Catalogs - SF-01 March 2014 - 2014 - 03 - 19 PDF
Approved Catalogs - SF-01 March 2014 - 2014 - 03 - 19 PDF
Approved Catalogs - SF-01 March 2014 - 2014 - 03 - 19 PDF
MARCH 2014
1|Page
Table of Contents
Company Profile . 2
Accessories . 22
Typical Application . 25
Warranty .. 26
Contacts / Inquiries 27
Company Profile
Certification
Saudi
Fan
Industries
Certifies Model DH shown
herein are Licenced to bear
the AMCA Sound and Air
Performance
seals.The
ratings shown are based on
tests
and
procedures
performed in accordance
with AMCA publication 211
,AMCA publication 311 and
comply with requirements of
the AMCA Certified Ratings
Programme .
2|Page
Insulation Class
The windings of fans comply with insulation class B/F.
In addition The windings have standard moisture
impregnation.
Thermal Protection
All external rotor motors except the explosion proof
motors are equiped with thermal contacts,embedded
in the windings to protect the motor.Thermal contacts
are bi-metallic cutouts,temperature dependant,when
properly wired they protect against overload,mainphase failure ,stalling of motor and too high ambient
temperatures.
Motor protection is guaranteed,when the thermal
contacts are wired trhrough a tip contactor circuit.
In connection with thermal contacts are recommend to
fit our supplied controllers for better motor protection.
For the exhaust of explosive mixture in temperature
classes T1 to T3 in Zone 1 and 2, we offer fans with
specific controllable motors in protection class e for
intrinsically safe application , according to DIN 50019.
Electrical Connection
Electrical connection will be made by an enclosed
terminal box with protection class IP 55
Selection of Fans .
The following must be considered when selecting
suitable fan :
3|Page
V1 n1
V2 = n2
Pst 1
n1 2
V1 2
Pst 2 =( n2 ) = ( V2 )
P1
n1
V1 3
=( )3 = (
)
P2
n2
V2
V1
D1 3
V2 = ( D2 )
Pst 1
D1 2
Pst 2 =( D2 )
The
Power
requirement
changes proportionately to the
fifth power of wheel diameter .
P1
D1 5
P 2 =( D2 )
Changes in the density at constant speed or change of Kelvin temperature at a constant flow medium :
The volume flow is not affected.
V= Constant
Pst 1 1
T2
Pst 2 = 2 = T1
P1
P2
1
T2
= = T
2
1
Pressure Units
Convert to
2
Pa (N/m )
bar
atmosphere
mm Hg
mm
H2O
0.0075
0.1
Convert from
Pa (N/m2)
bar
-5
1
105
5
atmosphere
1.01 10
mm Hg = 1Torr
133.3
mm H2O
10
m H2O
104
kg/cm2
9.8 10
lb/ ft
2
-6
10
9.87 10
-5
1.02 10
lb/ in2
(psi)
0.021
1.45 10
lb/ ft
-4
inches
Hg
-4
2.96 10
inches
H2O
-3
4.02 10
0.987
750
1.019 10
10.197
1.0197
2090
14.5
29.61
759.9
10332
10.332
1.03
2117.5
14.69
29.92
407
13.3
0.013
1.36 10
2.79
0.019
0.039
0.54
0.075
0.001
1.02 10
0.209
1.45 10
75
1000
0.102
209
1.45
2.96
735
10000
10
2049
14.21
29.03
394
0.36
4.78
0.0069
0.014
0.19
-3
1.33 10
1.32 10
0.000097
9.87 10
-5
-2
0.097
9.87 10
0.98
0.97
-4
47.8
-4
10
4
kg/cm
1.013
-3
m H2O
4.78 10
4.72 10
-4
-3
-4
-3
4.78 10
-4
4.88 10
-3
402
-3
2.96 10
0.04
40.2
lb/ in (psi)
6894.76
0.069
0.068
51.7
689.7
0.69
0.07
144
2.04
27.7
inches Hg
3377
0.0338
0.033
25.4
337.7
0.337
0.034
70.8
0.49
13.57
inches H2O
248.8
2.49 10
1.87
25.4
0.0254
0.0025
5.2
0.036
0.074
cfm
US gpd
US gpm
IMP gpd
IMP gpm
-3
-3
2.46 10
m /s
m /min
m /h
m /s
60
m3/min
0.0167
Convert from
3
liter/sec
liter/min
liter/h
3600
1000
60000
3600000
2119
22800000
15852
19000000
13200
60
16.67
1000
60000
35.32
380000
264.2
316667
220
m /h
0.000278
0.0167
0.278
16.67
1000
0.589
6333.3
4.403
5277.8
3.67
liter/sec
0.001
0.06
3.6
60
3600
2.119
22800
15.852
19000
13.2
liter/min
1.67 10
0.001
0.06
0.0167
60
0.0353
380
0.2642
316.7
0.22
liter/h
2.7 10
0.000017
0.001
0.00028
0.0167
0.00059
6.33
0.0044
5.28
0.0037
cfm
-5
-7
0.00047
-8
0.028
-6
US gpd
4.39 10
2.6 10
US gpm
0.000063
0.00379
-8
-6
IMP gpd UK
5.26 10
3.2 10
IMPgpm UK
0.000076
0.0046
1.699
0.472
28.32
1698.99
10760.3
7.48
8966.9
6.23
0.000158
0.000044
0.0026
0.158
0.000093
0.000695
0.833
0.000579
0.227
0.063
0.000189
0.272
-5
5.26 10
0.076
3.785
227.1
0.1337
1438.3
1198.6
0.833
0.00316
0.1895
0.00011
1.2
0.00083
0.00069
4.55
272.7
0.161
1727.3
1.2
1439.4
4|Page
Fan Introduction
Horizontal and Vertical outlet
Advantages
Application
Construction
Housing
Impellers
Motors
5|Page
190
1.75
40
1.50
35
1.25
30
25
1.00
H
20
0.75
15
0.50
10
5
0
0.25
Voltage [V]
: 230
0.00
0
0
50
1
100
2
150
4
200
5
250
7
300
8
350
400 V cfm
10
V cmm
11
Frequency[Hz] : 60
Pmax [kW]
: 0.08
Wir. Diagram
: 01.009
Imax [A]
: 0.33
: 5.5
DH 190-2E
100 %speed controllable motor
Direct
Drive
Operating
VOLT
IP : 44 Class : F
Fan
RPM
105
E-1188
130
145
160
230
0.15
0.25
0.5
0.75
CFM
157
72
37
SONES
4.7
1.8
1.8
CFM
212
146
90
38
SONES
6.8
4.6
2.9
3.7
CFM
236
179
132
61
SONES
7.7
6.3
4.4
3.8
CFM
270
220
183
96
53
SONES
8.5
7.3
6.2
4.1
4.1
CFM
357
331
314
256
189
127
SONES
12.4
12.4
10.8
11.0
7.1
7.1
F-1535
G-1701
H-1915
K-2577
Performance certified is for installation Type A : free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band. The Sound test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A : free inlet hemispherical sone levels.
6|Page
190
Fan
Up blast Discharge
DV190-2E
Pst Pst
[in
[mm
50 2.00
wg] wg]
45
1.75
40
1.50
35
1.25
30
25
1.00
H
20
0.75
15
0.50
10
5
0
0.25
Voltage [V]
0.00
0
0
50
1
100
2
150
4
200
5
250
7
300
8
350
9
10
: 230
Imax [A]
DV 190-2E
100 %speed controllable motor
Operating
VOLT
Fan
RPM
105
E-1188
130
145
160
230
: 0.08
Wir. Diagram
: 01.009
: 0.33
: 5.5
IP : 44 Class : F
Direct
Drive
0.15
0.25
0.5
0.75
CFM
157
72
37
SONES
4.7
1.8
1.8
CFM
212
146
90
38
SONES
6.8
4.6
2.9
3.7
CFM
236
179
132
61
SONES
7.7
6.3
4.4
3.8
CFM
270
220
183
96
53
SONES
8.5
7.3
6.2
4.1
4.1
CFM
357
331
314
256
189
127
SONES
12.4
12.4
10.8
11.0
7.1
7.1
F-1535
G-1701
H-1915
K-2577
Performance certified is for installation Type A :free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band.The test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A:free inlet hemispherical sone levels.
The AMCA Certified Ratings Seal does not apply to Model DV.
7|Page
225
Downblast Discharge
DH225-2E
Pst
Pst
[mm [in
3.50
wg] wg]
80
3.00
70
2.50
60
50
40
2.00
1.50
30
1.00
20
Voltage [V]
0.00
0
0
100
2
200
4
300
8
400
10
12
500
14
600
16
18
700
20
800
22
: 230
V cfm
V cmm
Frequency[Hz] : 60
Pmax [kW]
: 0.23
Wir. Diagram
: 01.009
Imax [A]
: 0.90
: 5.5
o
IP : 44 Class : F
Direct
Drive
Operating
VOLT
DH 225-2E
100 %speed controllable motor
10
E
0.50
Fan
RPM
105
E-1328
130
145
160
230
0.15
0.25
0.5
0.75
1.50
2.00
CFM
330
208
144
72
SONES
6.1
4.3
2.9
3.6
CFM
439
350
282
170
117
SONES
8.7
8.7
8.7
4.5
6.1
CFM
500
431
379
249
172
126
SONES
10.3
10.3
10.3
6.2
7.6
9.4
CFM
560
502
450
326
239
183
116
SONES
12.7
12.7
12.7
8.5
8.5
11.9
11.9
CFM
758
727
704
641
566
498
356
240
SONES
19.1
19.1
19.1
16.8
14.9
14.9
11.9
11.9
F-1736
G-1960
H-2157
K-2865
Performance certified is for installation Type A : free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band. The Sound test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A : free inlet hemispherical sone levels.
8|Page
225
Up blast Discharge
DV225-2E
Pst
[mm
wg]
Pst
[in
3.50
wg]
80
3.00
70
2.50
60
50
40
2.00
1.50
30
1.00
20
Voltage [V]
0.00
0
0
100
2
200
4
300
8
400
10
12
500
14
600
16
18
700
20
800
22
V cfm
V cmm
: 230
Frequency[Hz] : 60
Pmax [kW]
: 0.23
Wir. Diagram
: 01.009
Imax [A]
: 0.90
: 5.5
o
IP : 44 Class : F
Direct
Drive
Operating
VOLT
0.50
DV 225-2E
100 %speed controllable motor
10
Fan
RPM
105
E-1328
130
145
160
230
0.15
0.25
0.5
0.75
1.50
2.00
CFM
330
208
144
72
SONES
6.1
4.3
2.9
3.6
CFM
439
350
282
170
117
SONES
8.7
8.7
8.7
4.5
6.1
CFM
500
431
379
249
172
126
SONES
10.3
10.3
10.3
6.2
7.6
9.4
CFM
560
502
450
326
239
183
116
SONES
12.7
12.7
12.7
8.5
8.5
11.9
11.9
CFM
758
727
704
641
566
498
356
240
SONES
19.1
19.1
19.1
16.8
14.9
14.9
11.9
11.9
F-1736
G-1960
H-2157
K-2865
Performance certified is for installation Type A :free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band.The test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A:free inlet hemispherical sone levels.
The AMCA Certified Ratings Seal does not apply to Model DV.
9|Page
310
Pst Pst
[in
[mm 2.00
50 wg]
wg]
45
1.75
40
1.50
35
1.25
30
25
1.00
H
20
0.75
15
0.50
10
5
0
0.25
Voltage [V]
: 230
0.00
0
0
200
4
400
8
12
600
16
800
20
24
1000
28
1200 V cfm
32
Frequency[Hz] : 60
Pmax [kW]
: 0.20
Wir. Diagram
Imax [A]
: 0.82
V cmm
DH 310-4E
100 %speed controllable motor
Direct
Drive
Operating
VOLT
IP : 44 Class : F
Fan
RPM
105
E-434
130
145
160
230
: 01.009
: 11
o
0.15
0.25
0.5
0.75
1.25
CFM
356
122
SONES
2.4
1.4
CFM
514
281
187
SONES
4.2
2.6
2.8
CFM
608
376
278
161
SONES
5.7
3.4
3.0
4.3
CFM
713
522
403
254
178
SONES
7.7
4.7
3.9
4.4
4.4
CFM
1110
1043
997
871
730
587
424
SONES
14.7
14.7
14.7
12.4
10
7.6
7.6
F-718
G-894
H-1076
K-1578
Performance certified is for installation Type A : free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band.The Sound test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A : free inlet hemispherical sone levels.
10 | P a g e
310
Up blast Discharge
DV310-4E
Pst Pst
[in
[mm 2.00
50
wg] wg]
45
1.75
40
1.50
35
1.25
30
25
20
1.00
H
0.75
15
0.50
10
Voltage [V]
0.00
0
0
200
4
400
8
12
600
16
800
20
24
1000
28
1200 V cfm
32
: 230
Direct
Drive
Fan
RPM
105
E-434
130
145
160
230
Frequency[Hz] : 60
Pmax [kW]
: 0.20
Wir. Diagram
Imax [A]
: 0.82
V cmm
IP : 44 Class : F
Operating
VOLT
0.25
DV310-4E
100 %speed controllable motor
: 01.009
: 11
o
0.15
0.25
0.5
0.75
1.25
CFM
356
122
SONES
2.4
1.4
CFM
514
281
187
SONES
4.2
2.6
2.8
CFM
608
376
278
161
SONES
5.7
3.4
3.0
4.3
CFM
713
522
403
254
178
SONES
7.7
4.7
3.9
4.4
4.4
CFM
1110
1043
997
871
730
587
424
SONES
14.7
14.7
14.7
12.4
10
7.6
7.6
F-718
G-894
H-1076
K-1578
Performance certified is for installation Type A :free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band.The test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A:free inlet hemispherical sone levels.
The AMCA Certified Ratings Seal does not apply to Model DV.
11 | P a g e
355
Pst
[mm
60
wg]
Pst
2.50
[in
wg]
2.25
50
2.00
1.75
40
30
1.50
1.25
1.00
20
0.75
ALL DIMENSIONS ARE IN MM
0.50
10
0.25
0.00
0
0
300
5
10
600
15
900
20
25
1200
30
35
1500
40
45
1800 V cfm
50
V cmm
: 230
Operating
VOLT
Direct
Drive
Fan
RPM
105
E-788
130
145
160
230
Frequency[Hz] : 60
Pmax [kW]
: 0.40
Wir. Diagram
: 01.024
Imax [A]
: 1.64
: 21
IP : 54 Class : F
DH355-4E
100 %speed controllable motor
Voltage [V]
0.15
0.25
0.5
0.75
1.25
1.5
CFM
711
453
331
147
SONES
5.9
5.9
3.2
5.7
CFM
1032
844
705
445
303
SONES
10.1
10.1
6.6
8.1
CFM
1211
1052
934
632
476
366
SONES
12.4
12.4
12.4
7.3
9.2
9.2
CFM
1348
1257
1176
926
722
SONES
14.7
14.7
14.7
11
CFM
1577
1527
1481
SONES
18.8
18.8
18.8
1.75
557
430
301
11
8.9
12.9
12.9
1364
1244
1127
1011
821
653
17
17
14.9
14.9
12.8
12.8
F-1072
G-1212
H-1368
K-1636
Performance certified is for installation Type A : free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band. The Sound test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A : free inlet hemispherical sone levels.
12 | P a g e
355
Up blast Discharge
DV355-4E
Pst
Pst
2.50
[mm [in
60 wg]
wg]
2.25
50
2.00
1.75
40
30
1.50
1.25
F
1.00
20
0.75
0.50
10
0.25
0.00
0
0
300
5
10
600
15
900
20
25
1200
30
35
1500
40
45
: 230
Frequency[Hz] : 60
Pmax [kW]
: 0.40
Wir. Diagram
Imax [A]
: 1.64
1800 V cfm
50
V cmm
Operating
VOLT
Direct
Drive
Fan
RPM
105
E-788
130
145
160
230
: 01.024
: 21
o
IP : 54 Class : F
DV355-4E
100 %speed controllable motor
Voltage [V]
0.15
0.25
0.5
0.75
1.25
1.5
CFM
711
453
331
147
SONES
5.9
5.9
3.2
5.7
CFM
1032
844
705
445
303
SONES
10.1
10.1
6.6
8.1
CFM
1211
1052
934
632
476
366
SONES
12.4
12.4
12.4
7.3
9.2
9.2
CFM
1348
1257
1176
926
722
SONES
14.7
14.7
14.7
11
CFM
1577
1527
1481
SONES
18.8
18.8
18.8
1.75
557
430
301
11
8.9
12.9
12.9
1364
1244
1127
1011
821
653
17
17
14.9
14.9
12.8
12.8
F-1072
G-1212
H-1368
K-1636
Performance certified is for installation Type A :free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band.The test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A:free inlet hemispherical sone levels.
The AMCA Certified Ratings Seal does not apply to Model DV.
13 | P a g e
400
2.75
2.50
60
2.25
50
2.00
1.75
40
30
1.50
1.25
1.00
20
0.75
0.50
10
0.25
0
Voltage [V]
0.00
0
400
10
800
20
1200
30
1600
40
2000
50
: 230
2400 V cfm
60
V cmm
Frequency[Hz] : 60
Pmax [kW]
: 0.64
Wir. Diagram
: 01.024
Imax [A]
: 2.70
: 23
o
DH400-4E
100 %speed controllable motor
Direct
Drive
Operating
VOLT
IP : 54 Class : F
Fan
RPM
105
E-962
130
145
160
230
0.25
0.5
0.75
1.25
CFM
1249
935
632
SONES
11.3
10.3
9.9
CFM
1573
1355
1109
867
SONES
14.9
13.4
11.5
11
CFM
1748
1563
1337
SONES
17.7
17.7
CFM
1899
SONES
1.5
1.75
1128
902
654
14.3
14.3
12.7
14.3
1690
1488
1308
1134
936
678
19.3
19.3
16
16
14.3
14.6
14.6
CFM
2137
2026
1886
1740
1594
1451
1294
1076
766
SONES
24
24
21
21
18.8
18.8
18.8
16.7
16.7
F-1206
G-1320
H-1408
K-1612
Performance certified is for installation Type A : free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band. The Sound test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A : free inlet hemispherical sone levels.
14 | P a g e
400
Up blast Discharge
DV400-4E
Pst
[mm
wg]
Pst
[in
wg]
3.00
70
2.75
2.50
60
2.25
50
2.00
1.75
40
30
1.50
1.25
1.00
20
0.75
0.50
10
0.25
Voltage [V]
: 230
0.00
0
400
10
800
20
1200
30
1600
40
2000
50
2400 V cfm
Frequency[Hz] : 60
Pmax [kW]
: 0.64
Wir. Diagram
: 01.024
Imax [A]
: 2.70
: 23
V cmm
60
Direct
Drive
Operating
VOLT
IP : 54 Class : F
DV400-4E
100 %speed controllable motor
Fan
RPM
105
E-962
130
145
160
230
0.25
0.5
0.75
1.25
CFM
1249
935
632
SONES
11.3
10.3
9.9
CFM
1573
1355
1109
867
SONES
14.9
13.4
11.5
11
CFM
1748
1563
1337
SONES
17.7
17.7
CFM
1899
SONES
1.5
1.75
1128
902
654
14.3
14.3
12.7
14.3
1690
1488
1308
1134
936
678
19.3
19.3
16
16
14.3
14.6
14.6
CFM
2137
2026
1886
1740
1594
1451
1294
1076
766
SONES
24
24
21
21
18.8
18.8
18.8
16.7
16.7
F-1206
G-1320
H-1408
K-1612
Performance certified is for installation Type A :free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band.The test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A:free inlet hemispherical sone levels.
The AMCA Certified Ratings Seal does not apply to Model DV.
15 | P a g e
450
3.5
80
3.0
70
2.5
60
50
40
2.0
1.5
30
1.0
20
10
0.5
Voltage [V]
0
: 230
0.0
0
600
20
1200
40
1800
2400
60
3000
80
3600 V cfm
100
V cmm
Frequency[Hz] : 60
Pmax [kW]
: 1.26
Wir. Diagram
: 01.024
Imax [A]
: 5.15
: 32
o
DH450-4E
100 %speed controllable motor
Direct
Drive
Operating
VOLT
IP : 54 Class : F
Fan
RPM
105
E-896
130
145
160
230
0.25
0.5
0.75
1.25
1.5
CFM
1620
1304
839
SONES
13.9
12.6
11.3
CFM
2211
2022
1732
1364
1111
SONES
18.3
18.3
17
14.3
13.6
CFM
2573
2397
2214
1878
SONES
20
20
16.4
CFM
2885
2720
SONES
24
CFM
SONES
2.5
1626
1334
1115
16.4
16.2
16.2
13.9
2549
2330
2083
1801
1607
1183
24
22
22
22
22
15.7
17
3395
3233
3064
2910
2766
2622
2489
2241
1846
30
30
28
28
28
28
25
25
19.2
F-1202
G-1336
H-1470
K-1680
Performance certified is for installation Type A : free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band. The Sound test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A : free inlet hemispherical sone levels.
16 | P a g e
450
Up blast Discharge
DV450-4E
Pst
[mm
100
wg]
Pst
[in
4.0
wg]
90
3.5
80
3.0
70
2.5
60
50
40
2.0
1.5
30
1.0
20
10
0.5
Voltage [V]
0.0
0
0
600
20
1200
1800
40
2400
60
3000
80
3600 V cfm
100
V cmm
Frequency[Hz] : 60
Pmax [kW]
: 1.26
Wir. Diagram
Imax [A]
: 5.15
Operating
VOLT
Direct
Drive
Fan
RPM
105
E-896
130
145
160
230
: 01.024
: 32
o
IP : 54 Class : F
DV450-4E
100 %speed controllable motor
: 230
0.25
0.5
0.75
1.25
1.5
CFM
1620
1304
839
SONES
13.9
12.6
11.3
CFM
2211
2022
1732
1364
1111
SONES
18.3
18.3
17
14.3
13.6
CFM
2573
2397
2214
1878
SONES
20
20
16.4
CFM
2885
2720
SONES
24
CFM
SONES
2.5
1626
1334
1115
16.4
16.2
16.2
13.9
2549
2330
2083
1801
1607
1183
24
22
22
22
22
15.7
17
3395
3233
3064
2910
2766
2622
2489
2241
1846
30
30
28
28
28
28
25
25
19.2
F-1202
G-1336
H-1470
K-1680
Performance certified is for installation Type A :free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band.The test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A:free inlet hemispherical sone levels.
The AMCA Certified Ratings Seal does not apply to Model DV.
17 | P a g e
450
Pst
[in
4.5
wg]
100
4.0
90
3.5
80
K
H
3.0
70
60
2.5
50
2.0
40
1.5
30
1.0
20
10
0
0.5
0.0
0
0
600
20
1200
1800
40
2400
60
3000
80
3600
4200
100
Voltage [V]
V cfm
V cmm
: 230
Frequency[Hz] : 60
Pmax [kW]
: 1.54
Wir. Diagram
Imax [A]
: 6.25
DHW450-4E
100 %speed controllable motor
Operating
VOLT
Fan
RPM
105
E-800
130
145
160
230
: 32
o
IP : 54 Class : F
Direct
Drive
: 01.024
0.5
0.75
1.25
CFM
1525
670
SONES
CFM
2112
SONES
1.5
2.5
1428
1109
862
696
14.4
14.4
11.2
11.2
11.2
CFM
2617
2061
1735
1454
1226
1056
SONES
19.6
19.6
13.9
13.9
13.9
13.6
CFM
3020
2551
2280
1994
1743
1521
1158
SONES
24
24
18.1
18.1
18.1
16
18.3
CFM
3833
3564
3421
3259
3089
2919
2459
1967
1364
SONES
35
35
32
32
32
29
29
25
25
F-1074
G-1242
H-1370
K-1644
Performance certified is for installation Type A : free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band. The Sound test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A : free inlet hemispherical sone levels.
18 | P a g e
450
Up blast Discharge
DVW450-4E
Pst Pst
[mm [in
4.5
wg]
110 wg]
100
4.0
90
3.5
80
K
H
3.0
70
60
2.5
50
2.0
40
1.5
30
1.0
20
10
0
0.5
0.0
0
0
600
20
1200
1800
40
2400
60
3000
80
3600
100
4200
Voltage [V]
V cfm
V cmm
: 230
Frequency[Hz] : 60
Pmax [kW]
: 1.54
Wir. Diagram
Imax [A]
: 6.25
DVW450-4E
100 %speed controllable motor
Operating
VOLT
Fan
RPM
105
E-800
130
145
160
230
: 32
o
IP : 54 Class : F
Direct
Drive
: 01.024
0.5
0.75
1.25
CFM
1525
670
SONES
CFM
2112
SONES
1.5
2.5
1428
1109
862
696
14.4
14.4
11.2
11.2
11.2
CFM
2617
2061
1735
1454
1226
1056
SONES
19.6
19.6
13.9
13.9
13.9
13.6
CFM
3020
2551
2280
1994
1743
1521
1158
SONES
24
24
18.1
18.1
18.1
16
18.3
CFM
3833
3564
3421
3259
3089
2919
2459
1967
1364
SONES
35
35
32
32
32
29
29
25
25
F-1074
G-1242
H-1370
K-1644
Performance certified is for installation Type A :free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band.The test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A:free inlet hemispherical sone levels.
The AMCA Certified Ratings Seal does not apply to Model DV.
19 | P a g e
500
Pst
[in
5.5
wg]
5.0
120
4.5
100
4.0
3.5
80
60
3.0
2.5
2.0
40
1.5
ALL DIMENSIONS ARE IN MM
1.0
20
0.5
0
0.0
0
800
1600
20
40
2400
60
3200
80
4000
100
120
4800
140
5600 V cfm
V cmm
Frequency[Hz] : 60
Wir. Diagram
Imax [A]
: 4.23-4.22
DHW500-4D
100 %speed controllable motor
Operating
VOLT
Fan
RPM
180
E-1228
230
280
380
440
: 43
o
IP : 54 Class : F
Direct
Drive
: 01.006
0.5
1.5
2.5
3.5
CFM
3570
3096
2529
1889
1272
SONES
24
24
16.9
16.9
15.8
CFM
4218
3804
3371
2849
2271
1694
SONES
29
29
23
23
19.2
19.2
CFM
4507
4207
3846
3424
2932
2414
1765
SONES
33
33
27
27
23
24
24
CFM
4932
4673
4371
4020
3647
3216
2691
2014
SONES
37
37
32
32
28
28
28
25
CFM
5107
4831
4546
4218
3868
3415
2928
2376
1407
SONES
41
41
37
37
33
33
33
28
28
F-1402
G-1511
H-1634
K-1674
Performance certified is for installation Type A : free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band. The Sound test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A : free inlet hemispherical sone levels.
20 | P a g e
500
Up blast Discharge
DVW500-4D
Pst
[mm
wg]
Pst
[in
5.5
wg]
5.0
120
4.5
100
4.0
H
G
3.5
80
60
3.0
2.5
2.0
40
1.5
ALL DIMENSIONS ARE IN MM
1.0
20
0.5
0.0
0
800
1600
20
40
2400
60
3200
80
4000
100
120
4800
Frequency[Hz] : 60
Wir. Diagram
: 01.006
Imax [A]
: 43
5600 V cfm
140
V cmm
: 4.23-4.22
Direct
Drive
Operating
VOLT
IP : 54 Class : F
DVW500-4D
100 %speed controllable motor
Fan
RPM
180
E-1228
230
280
380
440
0.5
1.5
2.5
3.5
CFM
3570
3096
2529
1889
1272
SONES
24
24
16.9
16.9
15.8
CFM
4218
3804
3371
2849
2271
1694
SONES
29
29
23
23
19.2
19.2
CFM
4507
4207
3846
3424
2932
2414
1765
SONES
33
33
27
27
23
24
24
CFM
4932
4673
4371
4020
3647
3216
2691
2014
SONES
37
37
32
32
28
28
28
25
CFM
5107
4831
4546
4218
3868
3415
2928
2376
1407
SONES
41
41
37
37
33
33
33
28
28
F-1402
G-1511
H-1634
K-1674
Performance certified is for installation Type A :free inlet,free outlet per AMCA Standard 210. Performance rating includes the
effects of a bird screen and wind band.The test method per AMCA Standard 300-08,figure 3 Set up,The sound ratings
shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International
Standard 301.Values shown are for installation Type A:free inlet hemispherical sone levels.
The AMCA Certified Ratings Seal does not apply to Model DV.
21 | P a g e
Reducing Speed for fan , Available for Use with External rotor motors.
They provide an economical means of system balancing with direct drive fans.
Disconnecting Switches
A wide range selection of NEMA rated Switches are available for positive electrical shutoff and safety ,
including dust tight,rainproof,corrosion resistant.
Switches may be internally or externally mounted.
22 | P a g e
Pre fabricated roof curbs are made of galvanizes steel sheet . All roof curbs are insulated with fibre glass wool .
A wide variety of roof curbs are available, including flange and sound absorbing wool .
Dimensions :
Size
DH-DV 190
DH-DV 225
DH-DV 310
DH-DV 355
DH-DV 400
DH/W-DV/W 450
DHW-DVW 500
DHW-DVW 560
DHW-DVW 630
484
332
598
434
800
598
865
663
1180
938
Dampers
Dampers are designed to prevent outside air from entering back into the building when fan is off ,
Damper sizes are shown on each performance data page .
23 | P a g e
The motor drive shall be an external rotor motor type and shall have a minimum IP 44 or IP 54
protection class per DIN 40050 ; the insulation winding shall be class B/F construction with additional
protection against moisture.
Each external rotor motor shall have a built-in thermal overload protection and shall be 100 %
compatible with standard electronic speed controllers / multi-tap step-down transformers by varying fan
speed from 100% to 10% / or as desired rated speed .
The impeller shall be centrifugal backward inclined type constructed of plastic/aluminium/ galvanized
steel where required and shall be direct driven/close-coupled to an external rotor motor.
o
o
Fan shall be capable of handling upto a maximum of 60 C/140 F temperature of medium being
exhausted .
Fan impeller and external rotor motor shall be statically and dynamically balanced according to
DIN/ISO 1940-G2.5 Standards.
Fan Base/Ground plate and motor top plate shall be made from galvanized steel sheet and shall be
powder coated whenever extrra corrosion protection is necessary or specific contract.
Fan must be fitted with a bird-guard constructed from welded steel rings and powder coated against
corrosion protection.
Fan shall be fitted with a self acting Back draft Damper (opional).
Fan shall be fitted with an IP55 terminal box /or buit-in disconnecting switch to accept termination of
field wiring(optional).
Model DH shall be AMCA Licensed.
24 | P a g e
Typical Application
25 | P a g e
Warranty
Saudi Fan Industries warrants this equipment to be free from defects in material and
workmanship for a period of One year from the Delivery date .
Terms :
This warranty will cover for defective parts only excluding labour.
Any units or parts ,which proved defective during the warranty period will be replaced
at our option when returned to our factory .
26 | P a g e
27 | P a g e
28 | P a g e