DC Fans-Specials 2014 11 en
DC Fans-Specials 2014 11 en
DC Fans-Specials 2014 11 en
DC axial fans
DC fans - specials
161
Representatives
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / GreenTech
EC-Compact fans
DC fans - specials
DC centrifugal fans
164
168
173
177
2014-11
Speed signal
Alarm signal
Vario-Pro / Speed setting / Control input
Protection against ambient influences, Protection class IP 54 / IP 68
DC fans - specials
Technical information
2014-11
162
Information
DC centrifugal fans
DC axial fans
DC fans - specials
ACmaxx / GreenTech
EC-Compact fans
AC axial fans
AC centrifugal fans
Accessories
5. Turbo drives
Fans with three-phase EC drives and microprocessor-controlled motor
electronics. These three-phase motors whose torque is virtually nonreliant on the rotor position are used for extremely high running smoothness. The speed of these fans can be controlled over a very wide range
with PWM, analogue voltage or temperature. Optionally, the fans can be
supplied with reversible direction of rotation and active brake operation.
163
Representatives
4. Alarm signal
For applications which require monitored fan operation with alarm
signal, ebm-papst has numerous alarm signal versions, either a static,
pre-processed or interface-compatible high or low continuous signal
depending on the type of fan.
6. Vario-Pro fans
This high-end fan concept by ebmpapst with programmed intelligence
and customer-specific integrated functions makes your electronics
cooling even more versatile and competitive. Vario-Pro ensures a fresh
economic breeze for all demanding cooling tasks e.g. where greater
reliability, more flexibility and intelligent function features such as alarm
function, speed control etc. are required.
2014-11
3. Speed signal
DC fans with speed signal.
The integrated electronic tachometer continuously provides an actual
speed signal for external evaluation. The user is informed at all times of
the current fan speed via an extremely simple signal evaluation on the
customer side. The speed signal is via a separate lead.
DC fans - specials
Technical information
Speed signal /2
mA
VDC
mA VDC
mA
0,4
30
30
31
400 F
0,4
30
30
32
400
0,4
30
30
33
420 J
0,4
15
15
34
500 F
0,4
30
30
35
600 F
0,4
30
30
36
620
0,4
30
30
37
630 U
0,4
30
30
38
600 N
0,4
28
28
39
600 J
0,4
30
30
41
700 F
0,4
30
30
42
8450
0,4
28
28
43
8400 N
0,4
28
28
44
8400 N VARIOFAN
0,4
30
30
45
8300
0,4
30
30
46
8200 J
0,4
30
30
47
3400 N
0,4
28
28
48
3400 N VARIOFAN
0,4
30
30
49
3300
0,4
30
30
50
3300 N
0,4
30
30
51
3212 J / 3214 J
0,4
30
30
52
2014-11
Page
3218 J
0,4
60
60
52
3250 J
0,4
60
60
53
4412 F / 4414 F
0,4
30
30
54
4418 F
0,4
60
60
54
4400 FN
0,4
30
30
55
4312 / 4314
0,4
30
30
56
4318
0,4
60
60
56
30
30
57
4318 VARIOFAN
0,4
60
60
57
4400
0,4
30
30
2 58/59
4100 N
0,4
30
30
60
4100 NHH...NH6
0,4
60
60
10
61
4100 NH7...NH8
0,4
60
60
20
62
DV 4100
0,4
30
30
63
Subject to alternations
164
Fan description
Basic type
Condition: Isource
Speed signal
US High
VDC
Signal data
Sensor operating
voltage UBS max.
Condition: Isink
Type
250
Electrical connection
Ra
Speed signal
US Low
Information
Condition: Isource
Sensor operating
voltage UBS max.
mA
VDC
mA
VDC
mA
0,4
30
30
64
DV 5200
0,4
30
30
65
5112 N
0,4
15
20
66
5114 N / 5118 N
0,4
60
60
20
66
5300
0,4
72
72
67
5300 TD
0,4
72
72
20
68
7112 N / 7118 N
0,4
60
60
20
69
7114 N
0,4
30
30
20
69
7200 N
0,4
15
15
20
70
6300
0,4
72
72
20
72
6300 TD
0,4
72
72
20
73/74
6300 N
0,4
72
72
20
74 a
DV 6300
0,4
72
72
20
75
6400
0,4
60
60
20
76
2200 FTD
0,4
72
72
20
80
RL 48
0,4
30
30
95
RL 65
0,4
30
30
96
RL 90 N
0,4
30
30
97
RLF 100
0,4
30
30
98
RG 90 N
0,4
30
30
99
RG 125 N
0,4
30
30
100
RG 160 N
0,4
30
30
20
101
RG 160 NTD
0,4
60
60
20
102
RG 190 TD
0,4
72
72
20
103
RG 220 TD
0,4
72
72
20
104
RG 225 TD
0,4
72
72
20
105
RET 97 TD
0,4
72
72
20
106
REF 100
0,4
30
30
107
RER 120 TD
0,4
72
72
20
109
RER 133 TD
0,4
72
72
20
113
0,4
60
60
20
115
REF 175 TD
0,4
72
72
20
116
RER 175 TD
0,4
72
72
20
117
RER 190 TD
0,4
72
72
20
118
RER 220 TD
0,4
72
72
20
124
RER 225 TD
0,4
72
72
20
125
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / GreenTech
EC-Compact fans
DC fans - specials
Page
Note:
With these fan options, deviations in regard to temperature range, voltage
range and power consumption are possible compared with standard fan
data.
165
2014-11
Subject to alternations
DC centrifugal fans
Speed signal
US High
VDC
Representatives
Condition: Isink
Type
5200 N
Signal data
Fan description
Basic type
Speed signal
US Low
DC axial fans
Available on request:
Electrically isolated sensor and signal circuit
Varying voltage potentials for power and logic circuit
Fan description
Basic type
mA
Page
2,55,5
39
2,55,5
39
0,4
2,55,5
44
4412 F/12 GM
0,4
2,55,5
54
4418 F/12
0,4
2,55,5
54
4312 /12 M
0,4
2,55,5
56
4314 /12
0,4
2,55,5
56
4182 N/12 X
0,4
2,55,5
60
Type
VDC
mA
614 N/12 GM
0,4
618 N/12 N
0,4
8412 N/12 H
Speed signal
US High
mA
Condition: Isink
VDC
Signal data
Speed signal
US Low
Condition: Isource
Electrical connection
Subject to alternations
Note:
With these fan options, deviations in regard to temperature range, voltage range
and power consumption are possible compared with standard fan data.
2014-11
166
Information
1
20
70
0,4
2,55,5
20
76
DV 6424/12
0,4
4,55,25
12
78
DV 6448/12
0,4
4,55,25
12
78
RG 125-19/12 N/12
0,4
2,55,5
100
RG 160-28/12 N/12
0,4
2,55,5
101
RG 160-28/18 N/12
0,4
2,55,5
20
101
2,55,5
112
2,55,5
114
2,55,5
20
114
Speed signal
US Low
0,4
6424/12 H
DC centrifugal fans
2,55,5
7214 N/12
DC fans - specials
mA
ACmaxx / GreenTech
EC-Compact fans
Page
VDC
AC axial fans
Fan description
Basic type
mA
Type
Subject to alternations
167
2014-11
Accessories
AC centrifugal fans
Note:
With these fan options, deviations in regard to temperature range, voltage
range and power consumption are possible compared with standard fan data.
Representatives
mA
Signal data
Speed signal
US High
VDC
Condition: Isink
Condition: Isource
DC axial fans
Available on request:
Electrically isolated sensor and signal circuit
Varying voltage potentials for power and logic circuit
60
20
15
1500 100
46
60
n > nG
60
20
15
1500 100
46
60
n > nG
60
20
15
1500 100
50
n < nG
60
n > nG
60
20
15
850 100
56
n < nG
60
n > nG
60
20
15
1500 100
60
0,4
n < nG
3314 /17
0,4
n < nG
4318 /17
0,4
4184 N /17 X
0,4
0,4
8318 /17 H
Condition:
60
Alarm output
voltage UA Low
8318 /17
Subject to alternations
Note:
With these fan specials, deviations as regards temperature range,
voltage range and power consumption are possible compared with standard fans.
Electrical connection
Ra
2014-11
168
Fan description
Basic type
Alarm delay
time t2
n > nG
n < nG
VDC
Speed limit nG
Max. permissible
Sink current
VDC
Type
Condition:
mA
mA
Alarm
signal data
Condition:
VDC
mA
Condition:
Isink =
Condition:
Isource
RPM
Page
Information
1500 100
57
60
n > nG
60
20
15
1500 100
57
60
n > nG
60
20
15
1150 100
57
n < nG
60
n > nG
60
20
15
850 100
57
n < nG
60
n > nG
60
15
15
1330 60
70
0,4
n < nG
4318/17 T
VARIOFAN
0,4
7214 N/17
0,4
Subject to alternations
* After switching on UB
AC axial fans
4314/17 T
VARIOFAN
169
2014-11
Accessories
AC centrifugal fans
Note:
With these fan specials, deviations as regards temperature range,
voltage range and power consumption are possible compared with standard fans.
Representatives
Condition:
n < nG
Alarm output
voltage UA Low
0,4
4312/17 T
VARIOFAN
DC centrifugal fans
15
Page
DC fans - specials
20
RPM
ACmaxx / GreenTech
EC-Compact fans
Alarm delay
time t2
60
60
0,4
Fan description
Basic type
Max. permissible
Sink current
4312/17 MT
VARIOFAN
Speed limit nG
n > nG
n < nG
VDC
Condition:
Condition:
Isource
VDC
Type
Condition:
mA
VDC
Condition:
Isink =
mA
mA
Alarm
signal data
DC axial fans
Available on request:
With integrated signal latching for subsequent recognition of short-time faults
Alarm circuit open collector or TTL
Electrically isolated for maximum device safety
Defects in the power circuit do not affect the alarm circuit.
60
20
15
1500 100
46
n < nG
60
20
15
1500 100
56
60
n < nG
60
10
10 4
1800 20
70
28
n < nG
28
10
10 4
1900 100
98
28
n < nG
28
10
10 4
1900 100
108
n < nG
0,4
n > nG
60
7214 N/19
0,4
n > nG
RLF 100-11/14/19
0,4
n > nG
RER 101-36/18N/19 HH
0,4
n > nG
0,4
4312/19
Condition:
60
8314/19 H
Condition:
Alarm output
voltage UA Low
n > nG
VDC
Note:
With these fan specials, deviations as regards temperature range,
voltage range and power consumption are possible compared with standard fans.
Available on request:
With integrated signal latching for subsequent recognition of short-term faults.
Alarm circuit open collector or TTL.
Electrically isolated for max. device safety; defects in power circuit have no effect on the alarm circuit.
Electrical connection
Ra
2014-11
RPM
Page
* After switching on UB
Subject to alternations
170
Fan description
Basic type
Alarm delay
time t2
VDC
Type
Speed limit nG
Max. permissible
Sink current
mA
mA
Alarm
signal data
Condition:
VDC
mA
Condition:
Isink =
Condition:
Isource
Information
DC axial fans
DC centrifugal fans
n > nG
28
10
<1
45
n > nG
28
10
<1
49
RPM
DC fans - specials
28
Fan description
Basic type
mA
Speed limit nG
n nG
VDC
Condition:
28
mA
Alarm delay
time t2
Max. permissible
Sink current
Page
* After switching on UB
Subject to alternations
ACmaxx / GreenTech
EC-Compact fans
0,4
n nG
3412 N/37 GV
VDC
Condition:
Isource
0,4
mA
Condition:
VDC
Condition:
Isink =
Type
Condition:
Alarm
signal data
Alarm output
voltage UA Low
AC axial fans
Note:
With these fan specials, deviations as regards temperature range,
voltage range and power consumption are possible compared with standard fans.
Available on request:
Alarm circuit TTL compatible.
AC centrifugal fans
Electrical connection
Accessories
Ra
171
Representatives
2014-11
28
10
<1
33
n = nG
28
10
<1
36
28
n = nG
28
10
<1
39
28
n = nG
28
10
<1
*
*
*
39
28
n = nG
28
10
<1
48
28
n = nG
28
10
<1
48
n > nG
28
n = nG
28
10
<1
54
n > nG
28
n = nG
28
10
<1
54
0,5
n > nG
28
n = nG
28
10
<1
54
0,4
n > nG
30
n = nG
30
<1
*
*
*
*
*
*
55
0,5
n > nG
28
614 N/39 M
0,5
n > nG
618 N/39 N
0,5
n > nG
3412 N/39 H
0,5
n > nG
3414 N/39 HH
0,5
n > nG
4412 F/39 GL
0,5
4412 F/39 M
0,5
4414 F/39
4414 FN/39 H
612 F/39 H
Condition:
n = nG
0,5
Condition:
28
Alarm output
voltage UA Low
412/39
Note:
With these fan specials, deviations as regards temperature range,
voltage range and power consumption are possible compared with standard fans.
Electrical connection
Ra
2014-11
RPM
Page
* After switching on UB
Subject to alternations
172
Fan description
Basic type
n > nG
VDC
Speed limit nG
VDC
Type
Condition:
Max. permissible
Sink current
mA
mA
Alarm
signal data
Alarm delay
time t2
VDC
mA
Condition:
Isink =
Condition:
Isource
Information
Vario-Pro
DC centrifugal fans
DC axial fans
Motor management
High control accuracy due to digital
motor management
Higher operating efficiency due to
optimum adaptation of motor hardware
and software
Fan series
Page
Fan series
Page
Fan series
620
37
4100 NH...NH6
61
DV 6300
75
8400 N
44
4100 NH 7-8
62
6400
76
8300
46
DV 4100
63
DV 6400
78
8200 J
47
5200 N
64
RL 90 N
97
3400 N
48
DV 5200
65
RLF 100
98
3300
50
5100 N
66
RG 90 N
99
3300 N
51
5300
67
RG 125 N
100
3200 J
52
7100 N
69
RG 160 N
101
3250 J
53
7200 N
70
REF 100
107
4400 FN
55
6100 N
71
RER 101
108
4300
56
6300
72
RER 125 N
112
4100 N
60
6300 N
74 a
RER 160 N
114
ACmaxx / GreenTech
EC-Compact fans
DC fans - specials
Vario-Pro-Features
Representatives
173
2014-11
Accessories
AC centrifugal fans
AC axial fans
Page
n max
n max
n min
n min
30C
2014-11
174
50C
T min
T max
Information
DC fans - specials
DC centrifugal fans
DC axial fans
ACmaxx / GreenTech
EC-Compact fans
R1
R2
AC axial fans
R1
AC centrifugal fans
R2
175
Representatives
Accessories
2014-11
Standard curve P / A
4,7 K
PWM
Tach output
pulses per revolution
Isink max. 10 mA
white
10 K
Alarm
12 V
Temperature
control module
Speed setting
Speed setting
with
potentiometer
PWM 1 - 10 kHz
50002-1-0174
50003-1-0174
Speed display
12 V
Full speed
GND
blue
Speed setting
1 V - 10 V
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
start up at > 14 %
Customer circuit
Connection
GND
Tacho
0-10 V
PWM
Line 1
red
blue
white
violet
Line
Line
red
Tach
GND
blue
GND
white
2014-11
176
Tach output:
3 pulses / revolution
Control input (Impedance 100 k)
Fan
Information
Protected fans
against environmental influences
DC centrifugal fans
DC axial fans
DC fans - specials
ACmaxx / GreenTech
EC-Compact fans
Type of protection: IP 54 / IP 68
In the type of protection IP 54, the motor and circuit boards are coated
and therefore protected against spray water and moisture.
The type of protection IP 68 is important for ebm-papst products, as it
ensures a high degree of protection for the encapsulated motor and
electronic against foreign bodies and water, whilst protecting the user
against potential hazards upon contact. Types of protection higher than
IP 68 are possible upon request.
AC axial fans
The available solutions could be different depending on the fan size. We would be glad to
develop solutions tailored to the demands of your application.
6 Dust-proof
Accessories
No protection
177
2014-11
AC centrifugal fans
X No protection
Representatives
Moisture protection
Coated motor and printed circuit board protects against humidity and
condensation.
2014-11
178