Feature and Specifications Comparison Operating voltage Flow rate at 30psi (2 bar) Rated Pressure Whisper-Vane positive displacement technology, Self Priming SAE straight thread O-ring Ports (J1926 ISO 11926) (Not compatible with pipe thread ) Max Ambient air temperature Rated current in Amps. Motor service factor Max oil temperature Max oil viscosity
100psi (6.9 bar) >5ft (1.5m) -16 (1" or 25mm) 104f (40c) 3.2/1.6 3.8/1.9 1.15 392f (200c) ~6,000 cSt
VARNA Products
4305 Business Dr. Cameron Park, CA 95682, USA www.VarnaProducts.com
1 (888) 676-7770
+1 (530) 676-7770 (International)
Printed in USA 7/10/12 2008 VARNA Products
Engineers Corner
General
The XD9 pump delivers up to 9 gpm (34 l/m) of oil flow. It is a self-priming and quiet-running vane pump for use in a wide variety of transfer or circulating applications with non-corrosive fluids such as oils and coolants. It can handle fluids with poor lubricity or low film strength, and produce over 100 psi (6.9 bar) pressure.
Plumbing Considerations
Excessive pressure drop caused by small pipes can be detrimental to system performance. Relative to hydraulic pumps this is a high flow, low pressure pump, optimized for efficiency in transfer applications. Small suction hoses/pipes will starve the pump and reduce output flow by causing cavitation. Small pressure pipes will create excessive backpressure that will exceed the rating of the pump. Therefore, elbows and long runs of pipe should be avoided. Each elbow and each inch of pipe has a cumulative effect. Pluming loses with cold or high viscosity fluid can easily add up to a large percent of available pressure when the plumbing is too restrictive. The pump itself produces flow not pressure. Like a turnstile, every rotation of the pump delivers a metered volume to the other side. Whatever system is connected to the pump has flow resistance, which is the source of the backpressure as the pump works to maintain flow. It is recommended that hose or pipe no smaller than 1 (25mm) be used and that the suction hose in particular is kept as short as possible and no longer than 36.
Motor Protection
Class 20 motor protection in the motor starter is recommended.
Application Engineering
It is challenging to address every possible installation type. We are always happy to help in choosing an appropriate installation setup. Give us a call for engineering assistance and support. 888-676-7774