Re91401 A2fo

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

RE 91 401/09.

00

RE 91 401/09.00
replaces: 01.97

Fixed Displacement Pump A2FO


for open circuits
Sizes 5...1000
Series 6
Nominal pressure up to 400 bar
Peak pressure up to 450 bar

A2FO

Index
Features
Ordering Code / Standard Program
Technical Data
Ordering Code - Size 5
Unit Dimensions, Size 5
Unit Dimensions, Sizes 10, 12, 16
Unit Dimensions, Sizes 23, 28, 32
Unit Dimensions, Size 45
Unit Dimensions, Sizes 56, 63
Unit Dimensions, Sizes 80, 90
Unit Dimensions, Sizes 107, 125
Unit Dimensions, Sizes 160, 180
Unit Dimensions, Size 200
Unit Dimensions, Size 250
Unit Dimensions, Size 355
Unit Dimensions, Size 500
Unit Dimensions, Size 710
Unit Dimensions, Size 1000
Preferred Types
Installation and Commissioning Guidelines

A2FO

Features
1
2
3...6
7
7
8
9
10
11
12
13
14
15
15
16
16
17
17
18
19

Fixed displacement pump A2FO of axial piston, bent axis design


is made suitable for hydrostatic drives in open circuits.
Suitable for use in mobile or industrial applications.
Output flow is proportional to drive speed and displacement.
The drive shaft bearings are designed to give the service life
expected in these areas of operation.
Careful selection of the displacements offered, permit sizes to be
matched to practically every application.
Favourable power / weight ratio
Compact and economical design
Optimum efficiency
One piece pistons with piston rings

1/20

Brueninghaus
Hydromatik

RE 91 401/09.00

Ordering Code / Standard Program


(Ordering code size 5 see page 7)

A2F
Hydraulic fluid
Mineral oil (no code)
HFB-, HFC-, HFDsizes 10...200 (no code)
fluids
sizes 250...1000 1)

/ 6

E-

Axial piston unit


Bent axis design, fixed displacement

A2F

Drive shaft bearings


Mechanical bearings (no code)
Long-Life bearings

10...200 250..500 710..1000

Mode of operation
Pump, open circuit

Size
Displacement Vg (cm3)
5 10 12 16 23

28

32

45

56

63

80

90 107 125 160 180 200 250 355 500 710 1000

Sizes 5...200: production Elchingen plant; sizes 250...1000: production Horb plant

Series
6
Index

Direction of rotation
Viewed on shaft end

sizes 10...180
size 200
sizes 250...1000

1
3
0

clockwise
anti-clockwise

R
L

Seals
NBR (nitril-caoutchouc)
NBR (nitril-caoutchouc), shaft seal in FKM (fluor-caoutchouc)
FKM (fluor-caoutchouc)
Shaft end
Splined shaft
DIN 5480
Parallel shaft with
key, DIN 6885

10

Mounting flange 10
ISO 4-hole
ISO 8-hole

12

16

23

28

32

45

56

10...200 250...1000

63

80

90

107 125 160 180 200 250 355 500 710 1000

12

16

23

28

32

45

56

63

80

90

Service line connections 2)


A(B) SAE, at side

S SAE, at rear
A(B) threads at side
S threads, at rear
A(B) SAE, at rear

S SAE, at rear

Brueninghaus Hydromatik

= available
= not available

B
H

05

06

2/20

A
Z
B
P

107 125 160 180 200 250 355 500 710 1000

= preferred program
(preferred types see page 18)

P
N
V

11

) only in connection with drive shaft bearings "L"


) threads of fixing screws are metric

A2FO

RE 91 401/09.00

Technical Data
Fluid
To review the application of A2FO pumps with the selected hydraulic
fluid, detailed fluid compatibility and application data can be found
in data sheets RE 90220 (mineral oil), RE 90221 (environmentally
acceptable hydraulic fluids) and RE 90223 (fire resistant fluids, HF).
The fixed pump A2FO is not suitable for operation with HFA. When
using HFB-, HFC-, HFD- or environmentally acceptable hydraulic fluids
possible limitations for the technical data have to be taken into
consideration. If necessary please consult our technical department
(please indicate type of the hydraulic fluid used for your application
on the order sheet).
Operating viscosity range
In order to optain optimum efficiency and service life, we recommend
that the operating viscosity (at operating temperature) be selected
from within the range:
opt = operating viscosity 16...36 mm2/s
referred to the tank temperature (open circuit).
Viscosity limits
The limiting values for viscosity are as follows:
Sizes 5...200
min = 5 mm2/s,
short term at a max. permissible temperature of tmax = 115C
max = 1600 mm2/s,
short term on cold start (tmin = -40C)

Sizes 250...1000
min = 10 mm2/s,
short term at a max. permissible leakage oil temp. of tmax = 90
max = 1000 mm2/s,
short term on cold start (tmin = -25C)
Please note that the max. fluid temperature is also not exceeded in
certain areas (for instance bearing area).
At temperatures of -25C up to -40C special measures may be
required for certain installation positions. Please contact us for
further information.
Selection diagram
2500-40
1600
1000
600
400

-20

20

40

60

80 100

1600

60
40

36
opt.

20

Direction of flow
clockwise rotation

anti-clockwise rotation

S to B

S to A

Connections
A, B Service line ports
S
Suction port
T
Drain port
U Port for bearing flushing
(sizes 250...1000)

0
10
G
V 68
G
V 46
G
V 32
G
V 2
2

100

Filtration
The finer the filtration the better the achieved cleanliness level of the
pressure fluid and the longer the life of the axial piston unit.
To ensure the functioning of the axial piston unit a minimum
cleanliness level of
9 to NAS 1638
18/15 to ISO/DIS 4406 is necessary.
At very high temperatures of the hydraulic fluid (90C to max. 115C,
not permissible for sizes 2501000!) at least cleanliness level
8 to NAS 1638
17/14 to ISO/DIS 4406 is necessary.
If above mentioned grades cannot be maintained please consult
supplier.

Symbol

VG

200

viscosity (mm2/s)

Notes on the selection of the hydraulic fluid


In order to select the correct fluid, it is necessary to know the operating
temperature in the tank (open circuit) in relation to the ambient
temperature.
The hydraulic fluid should be selected so that within the operating
temperature range, the operating viscosity lies within the optimum
range (opt) (see shaded section of the selection diagram). We
recommend that the highest possible viscosity range should be chosen
in each case.
Example: At an ambient temperature of XC the operating
temperature is 60C. Within the operating viscosity range (opt; shaded
area), this corresponds to viscosity ranges VG 46 or VG 68. VG 68
should be selected.
Important: The leakage oil (case drain oil) temperature is influenced
by pressure and pump speed and is always higher than the tank
temperature. However, at no point in the circuit may the temperature
exceed 115C for sizes 5200 or 90C for sizes 2501000.
If it is not possible to comply with the above conditions because of
extreme operating parameters or high ambient temperatures please
consult us.

16

B (A)

10

5
-40

-25

-10 0 10

30

50

70

90

5
115

temperature t (C)
tmin = -40C

A2FO

fluid temperature range

tmax = +115C

3/20

Brueninghaus Hydromatik

RE 91 401/09.00

Technical Data
Case drain pressure
Shaft seal ring FKM (fluor-caoutchouc)
The lower the speed and the case drain pressure the higher the life
expectation of the shaft seal ring. The values shown in the diagram
are permissible loads of the seal ring and shall not be exceeded.
With constant case pressure in the range of the max. permissible
case pressure a reduction of the life expectancy of the seal ring will
result.
For a short period (t < 5 min.) for the sizes 5200 pressure loads up
to 5 bar independent from rotational speeds are permissible.

Sizes 10...200

Working pressure range inlet


Minimum pressure at port S
pabs. min _______________________________________________________________ 0,8 bar
Working pressure range outlet
Maximum pressure at port A or B
(Pressure data to DIN 24312)

Size 5

Shaft end B

Shaft end C

Nominal pressure pN

210 bar

315 bar

Peak pressure pmax

250 bar

350 bar

Shaft end A, Z 2)

Shaft end B, P

Nominal pressure pN

400 bar

350 bar

Peak pressure pmax

450 bar

400 bar

10

Sizes 10...200 1)

perm. pressure pabs. max. (bar)

sizes 10, 12, 16

8
7

sizes 23, 28, 32

) Attention: shaft end Z and P with drives of radial force loads at


the drive shaft (pinion V-belt drives) necessitate reduction of the
nominal pressure to pN = 315 bar.
2) shaft end Z for size 56: pN = 350 bar, pmax = 400 bar

size 45

sizes 80, 90
4

sizes 107, 125

sizes 160, 180

2
1

sizes 56, 63

Sizes 250...1000

size 200
0

1000

2000

3000

4000

5000

6000

7000

8000

speed n (rpm)

Sizes 250...1000

perm. pressure pabs. max. (bar)

350 bar

Peak pressure pmax

400 bar

With pulsating loads above 315 bar we recommend using the model
with splined shaft, standard version A (sizes 10200) or with splined
shaft Z (sizes 2501000).

size 250

3,5

Nominal pressure pN

size 355

Long-Life bearings (L) (sizes 250...1000)


(for high life expectancy and use of HF-fluids)
The outer dimensions of the axial piston pumps are identical to
standard design (without long life bearings). The change from
standard design to long life bearing system is possible. We recommend
to apply bearing flushing at port U.

3
2,5

sizes 500

sizes 710
1,5

size 1000
1
0

250

500

750

1000

1250

1500

1750

2000

speed n (rpm)
Shaft seal ring NBR (nitril-caoutchouc) sizes 5...200
For seal rings of NBR 33% reduced values for the max. permissible
housing pressure pabs.max. are to be considered compared with seals
of FKM.
Special operation conditions may require limitations of these values.
Note:
- maximum permissible pump speeds are given in the table on page 5
- max. perm. casing pressure pabs. max ___ 10 bar (sizes 5...200)
___ 4 bar (sizes 250...1000)
- the pressure in the housing must be the same as or greater than
the external pressure on the shaft seal

Brueninghaus Hydromatik

Temperature range of the shaft seal ring


The FKM shaft seal is admissible for a temperature range from
-25C to +115C. For applications below -25C a NBR shaft seal is
necessary (admissible temperature range -40C to +90C) (special
design for sizes 250...1000).
Bearing flushing
For sizes 250...1000 bearing and housing flushing is possible through
port U.

Flushing flow (recommendation)


Size

250

355

500

710

1000

qflush (L/min)

10

16

20

25

25

4/20

A2FO

RE 91 401/09.00

Technical Data
Table of values (theoretical values, without considering mh and v; values rounded)
Size
Displacement
Max. speed 1)
Max. perm. speed with increased
input pressure pabs
Max. perm. output flow, at nmax2)
Max. power
p = 350 bar
at qv max
p = 400 bar
Torque constants
Perm. torque
p = 350 bar
p = 400 bar
Case volume
Moment of inertia
about drive axis
Weight (approx.)

10

12

16

23

28

32

45

56

63

80

Vg
nmax

cm3
rpm

4,93
5600

10,3
3150

12,0
3150

16,0
3150

22,9
2500

28,1
2500

32
2500

45,6
2240

56,1
2000

63 80,4
2000 1800

nmax perm.

rpm

8000

6000

6000

6000

4750

4750

4750

4250

3750

3750 3350

qV max
Pmax
Pmax
TK
T
T

L/min
kW
kW
Nm/bar
Nm
Nm
L

27
32
14,5 3) 19

22
0,076 0,164
24,7 3) 57

65
0,17

37
22
25
0,19
67
76
0,17

49
29
34
0,25
88
100
0,17

56
33
38
0,36
126
144
0,20

68
78
99
41
47
60
47
53
68
0,445 0,509 0,725
156
178
254
178
204
290
0,20 0,20 0,33

109
65
75
0,89
312
356
0,45

122
74
84
1,0
350
400
0,45

kgm2

0,00008 0,0004

0,0004

0,0004

0,0012

0,0012

0,0012

0,0024

0,0042

0,0042 0,0072

kg

Vg
nmax

cm
rpm

nmax perm.

140
84
96
1,27
445
508
0,55

2,5

5,4

5,4

5,4

9,5

9,5

9,5

13,5

18

90

107

1 25

160

180

200

250

355

500

710 1000

90 106,7
1800 1600

125 160,4 180


1600 1450 1450

200
1550

250
1500

355
1320

500
1200

710 1000
1200 950

rpm

3350

3000

3000

2650

2650

2750

1800

1600

1500

1500 1200

qV max
Pmax
Pmax
TK
T
T

L/min
kW
kW
Nm/bar
Nm
Nm
L

158
95
108
1,43
501
572
0,55

167
100
114
1,70
595
680
0,8

196
117
133
1,99
697
796
0,8

228
135
155
2,55
889
1016
1,1

255
152
174
2,86
1001
1144
1,1

304
181
207
3,18
1114
1272

364
219

3,99
1393

2,5

455
273

5,65
1978

3,5

582
350

7,96
2785

826 922
497 554

11,3 15,9
3955 5570

7,8

kgm2

kg

Size
Displacement
Max. speed 1)
Max. perm. speed with increased
input pressure pabs
Max. perm. output flow, at nmax2)
Max. power
p = 350 bar
at qv max
p = 400 bar
Torque constants
Perm. torque
p = 350 bar
p = 400 bar
Case volume
Moment of inertia
about drive axis
Weight (approx.)

0,0072 0,0116 0,0116 0,0220 0,0220 0,0378 0,061 0,102 0,178


23

32

32

45

45

66

73

110

155

18

23

0,55

0,55

322

336

) The values shown are valid for an absolute pressure (pabs) of 1 bar at the suction inlet S and when operated on mineral oil.
By increase of the input pressure (pabs > 1 bar) the rotational speeds can be increased to the max. admissible speeds (speed limits) (see diagram).

) p = 315 bar

) 3 % volumetric loss included

inlet pressure pabs in bar

Maximum permissible speed with increased inlet pressure


pabs at suction port S
4

qV =

Torque

T=

Power

P = 2 T n = T n = qV p
60 000
9549 600 t

sizes 250...1000

sizes 5...200

0,8

1,0

1,2

1,4

1,6

Note:
- max. perm. speed nmax perm. (speed limit)
- min. perm. pressure at port S
- admissible values for the drive shaft seal

1,8

2,0

speed n/nmax

Vg n v
1000

Flow

A2FO

Calculation of size

Vg =
T =
p =
n =
v =
mh=
t =
5/20

Vg p
20 mh

in L/min

1,59 Vg p
100 mh

geometric displacement per rev.


torque
pressure differential
speed
volumetric efficiency
mech. -hyd. efficiency
overall efficiency

in Nm

in kW

in cm3
in Nm
in bar
in rpm

Brueninghaus Hydromatik

RE 91 401/09.00

Technical Data
Output drive
Permissible axial and radial loads on drive shaft
The values given are maximum values and do not apply to continuous operation
Size

10

12

16

23

28

32

45

56

63

80

mm

12

16

16

16

16

16

16

18

18

18

20

Fq max

710

2350

2750

3700

4300

5400

6100

8150

9200

10300

11500

Fax max

180

320

320

320

500

500

500

630

800

800

1000

Fax perm./bar

N/bar

1,5

3,0

3,0

3,0

5,2

5,2

5,2

7,0

8,7

8,7

10,6

90

107

125

160

180

200

250

355

500

710

1000

20

20

20

25

25

25

41

52,5

52,5

67,5

67,5

Size
a

mm

Fq max

12900

13600

15900

18400

20600

22900

12001)

15001)

19001)

30001)

26001)

Fax max

N +Fax max 1000

1250

1250

1600

1600

1600

4000

5000

6250

10000

10000

1000

1250

1250

1600

1600

1600

1200

1500

1900

3000

2600

10,6

12,9

12,9

16,7

16,7

16,7

- Fax max
Fax perm./bar
1
2

N/bar

) Axial piston unit in stationary or in bypass operation, please contact us when appearing higher forces!
) Please contact us!

Code explanation
Fq
a
= distance of Fq from shaft shoulder
Fq max
= max. perm. radial force at distance a
(at intermittent operation)
a
Fax max
= max. perm. axial force when stationary
or when axial piston unit is running at zero pressure
Fax perm./bar= perm. axial force/bar working pressure

The direction of the max. perm. axial force must be noted by


sizes 5...200:
= increases bearing life
- Fax
Fax
+ Fax
= reduces bearing life
+
(avoid if possible)

Optimal force direction of Fq (valid for sizes 10...180)


By means of appropriate force directions of Fq the bearing load caused
by inside rotary group forces can be reduced. An optimal life
expectation of the bearing can be reached.
opt
0
=7

pt

op

=4
5

=7

pt
o

= 45

clockwise rotation
pressure at port B

anti-clockwise rotation
pressure at port A

Brueninghaus Hydromatik

clockwise rotation
pressure at port B

6/20

A2FO

RE 91 401/09.00

Ordering Code / Standard Program - Size 5

A2F 5
Axial piston unit
Bent axis design, fixed displacement

6.0

A2F
Additional instructions in text form

Size
Displacement Vg (cm3)

Direction of rotation
Viewed on shaft end

clockwise
anti-clockwise

Seals
The fixed pump A2F 5 is equipped with NBR(nitril-caoutchouc) seals in standard design.
In case of need FKM- (fluor-caoutchouc) seals
please indicate when ordering in clear text:
"with FKM-seals"

R
L

Series
6.0
Shaft end
Parallel shaft with key DIN 6885
Tapered shaft with spigot and spring washer DIN 6888

B
C

Service line connections


Threads at side, metric

= preferred program
(preferred types see page 18)

Unit Dimensions, Size 5


Before finalising your design, please request a certified drawing.

Note:
For anti-clockwise rotation port
plate is rotated through 180

Detail Y

70
74,
5
5

62

48,5

6,4

25

0,1

75

4
51

70

60 h8

R6

58,

17,

80

B (A)
Connections
B, (A) Service line ports
S
Suction port
T
Drain port

Shaft ends
B Parallel shaft with
key A4x4x20
DIN 6885

C Tapered shaft with spigot


and spring washer 3x5
DIN 6888

M18x1,5
M22x1,5
M10x1, both sides

taper 1:10
pN = 210 bar
A2FO

pN = 315 bar
7/20

Brueninghaus Hydromatik

RE 91 401/09.00

Unit Dimensions, Sizes 10, 12, 16


Before finalising your design, please request a certified drawing.

Note:
For anti-clockwise rotation port
plate is rotated through 180
64,5

45

T1

20 12
6

45

95
5

B (A)

R 10

10

18,2

85

95

,5
41

10

23,5

55,5
69
93,5

53,5

48,5

40

80 h6

42,5

16

T2
130,5
147
167,5
Connections
B(A) Service line ports
S
Suction port
T1,T2 Drain port (1 port plugged)
R
Air bleed (plugged)

M22x1,5
M33x2
M12x1,5
M8x1

Shaft ends
Sizes 10, 12, 16
A Splined shaft, DIN 5480
W 25x1,25x30x18x9g

pN = 400 bar

Brueninghaus Hydromatik

Sizes 10, 12
Z Splined shaft, DIN 5480
W 20x1,25x30x14x9g

Sizes 10, 12, 16


B Parallel shaft with key,
AS 8x7x32, DIN 6885

pN = 400 bar

pN = 350 bar

8/20

Sizes 10, 12
P Parallel shaft with key,
AS 6x6x32, DIN 6885

pN = 350 bar

A2FO

RE 91 401/09.00

Unit Dimensions, Sizes 23, 28, 32


Before finalising your design, please request a certified drawing.

Note:
For anti-clockwise rotation port
plate is rotated through 180
60,7
25 18
8

45

T1

118

23,2

B (A)

R 12

47,6
19

14

T2

106

118

12

,2

11

40 48,
5
13 ,5

18

70
91
120

55,5

61,5

40

19

S
22,2

19

100 h6

45

60

14

M10; 17 deep
144
169
193

M8; 15 deep

Connections
B(A) Service line ports
SAE 1/2"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 3/4"
350 bar (5000 psi) standard series
T1,T2 Drain port (1 port plugged)
M16x1,5
R
Air bleed (plugged)
M10x1

Shaft ends
Sizes 23, 28, 32
A Splined shaft, DIN 5480
W 30x2x30x14x9g

pN = 400 bar

A2FO

Sizes 23, 28
Z Splined shaft, DIN 5480
W 25x1,25x30x18x9g

Sizes 23, 28, 32


B Parallel shaft with key,
AS 8x7x40, DIN 6885

pN = 400 bar

pN = 350 bar

9/20

Sizes 23, 28
P Parallel shaft with key,
AS 8x7x40, DIN 6885

pN = 350 bar

Brueninghaus Hydromatik

RE 91 401/09.00

Unit Dimensions, Size 45


Before finalising your design, please request a certified drawing.

Note:
For anti-clockwise rotation port
plate is rotated through 180
60,3

45

T1
R 16

25

S
26,2

B (A)

11

16

,8

118

23

150

52

15
8

50
19 ,8

63

78

40

125 h6

18

52,4

13,5

18

30

45
150

80
102
132

32 20
12

63,5

20

M10; 17 deep

T2

155
181
206

M10; 17 deep
Connections
B(A) Service line ports
SAE 3/4"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 1"
350 bar (5000 psi) standard series
T1,T2 Drain port (1 port plugged)
M18x1,5
R
Air bleed (plugged)
M12x1,5

Shaft ends
A Splined shaft, DIN 5480
W 32x2x30x14x9g

pN = 400 bar

Brueninghaus Hydromatik

P Parallel shaft with key,


AS 8x7x50, DIN 6885

Z Splined shaft, DIN 5480


W 30x2x30x14x9g

pN = 400 bar

pN = 350 bar

10/20

A2FO

RE 91 401/09.00

Unit Dimensions, Sizes 56, 63


Before finalising your design, please request a certified drawing.

Note:
For anti-clockwise rotation port
plate is rotated through 180
45

T1

45

150
18

30

R 16
16

B (A)

52,4
25

150

128

16

13,5

56

11

23
,8
87
109
142

50
19 ,8

78
70

40

125 h6

9,

18

S
26,2

67,5
32 20
10

23

68

M10; 17 deep

T2

171
197
225

M10; 17 deep
Connections
B(A) Service line ports
SAE 3/4"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 1"
350 bar (5000 psi) standard series
T1,T2 Drain port (1 port plugged)
M18x1,5
R
Air bleed (plugged)
M12x1,5

Shaft ends
Sizes 56, 63
A Splined shaft, DIN 5480
W 35x2x30x16x9g

pN = 400 bar

A2FO

Size 56
Z Splined shaft, DIN 5480
W 30x2x30x14x9g

Sizes 56, 63
B Parallel shaft with key,
AS 10x8x50, DIN 6885

pN = 350 bar

pN = 350 bar

11/20

Size 56
P Parallel shaft with key,
AS 8x7x50, DIN 6885

pN = 350 bar

Brueninghaus Hydromatik

RE 91 401/09.00

Unit Dimensions, Sizes 80, 90


Before finalising your design, please request a certified drawing.

Note:
For anti-clockwise rotation port
plate is rotated through 180
45

T1

165

9,

11

18

,8

138

61

57
,2
25

15

B (A)

99
122
160

32

R 16

18

27
83

85,5

40

140 h6

29

58,7

30,2

15

45

13,5
165

78,5
32 20
10

73

25
M10; 17 deep

T2
196
223,5
255

M12; 17 deep

Connections
B(A) Service line ports
SAE 1"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 1 1/4"
280 bar (4000 psi) standard series
T1,T2 Drain port (1 port plugged)
M18x1,5
R
Air bleed (plugged)
M12x1,5

Shaft ends
Sizes 80, 90
A Splined shaft, DIN 5480
W 40x2x30x18x9g

pN = 400 bar

Brueninghaus Hydromatik

Size 80
Z Splined shaft, DIN 5480
W 35x2x30x16x9g

Sizes 80, 90
B Parallel shaft with key,
AS 12x8x56, DIN 6885

pN = 400 bar

pN = 350 bar

12/20

Size 80
P Parallel shaft with key,
AS 10x8x56, DIN 6885

pN = 350 bar

A2FO

RE 91 401/09.00

Unit Dimensions, Sizes 107, 125


Before finalising your design, please request a certified drawing.

Dimensions brackets for size 107

Note:
For anti-clockwise rotation port
plate is rotated through 180
45

T1

66

20

,8

12

190

89

T2

S
150

27

69,9
38

35,7

B (A)

21
2
31
,8
(

136
173

,7
6
32 (5 7 7
(2 ,2 )
5)

85

40

160 h6

98

18

45

R 20

110

18

36,5

190

17,5

82,8
23
40
10

20
M12; 20 deep

213
245
275

M14; 19 deep
(M12; 17 deep)

Connections
B(A) Service line ports
SAE 1 1/4" (1")
420 bar (6000 psi) high pressure series
S
Suction port
SAE 1 1/2"
210 bar (3000 psi) standard series
T1,T2 Drain port (1 port plugged)
M18x1,5
R
Air bleed (plugged)
M14x1,5

Shaft ends
Sizes 107, 125
A Splined shaft, DIN 5480
W 45x2x30x21x9g

pN = 400 bar

A2FO

Size 107
Z Splined shaft, DIN 5480
W 40x2x30x18x9g

Sizes 107, 125


B Parallel shaft with key,
AS 14x9x63, DIN 6885

pN = 400 bar

pN = 350 bar

13/20

Size 107
P Parallel shaft with key,
AS 12x8x63, DIN 6885

pN = 350 bar

Brueninghaus Hydromatik

RE 91 401/09.00

Unit Dimensions, Sizes 160, 180


Before finalising your design, please request a certified drawing.

Note:
For anti-clockwise rotation port
plate is rotated through 180
45

210

T1

32

22

,8

180

210

31

S
35,7

69,9
42

12,5

T2

B (A)

150
188

23

77
,5

,5

,7

19,5

66

95,5

108

40

180 h6

37,2

R 20

121

19

45

17,5

93
40 25
10

101

15

M12; 20 deep
237
271
294

M14; 19 deep

Connections
B(A) Service line ports
SAE 1 1/4"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 1 1/2"
210 bar (3000 psi) standard series
T1,T2 Drain port (1 port plugged)
M22x1,5
R
Air bleed (plugged)
M14x1,5

Shaft ends
Sizes 160, 180
A Splined shaft, DIN 5480
W 50x2x30x24x9g

pN = 400 bar

Brueninghaus Hydromatik

Size 160
Z Splined shaft, DIN 5480
W 45x2x30x21x9g

Sizes 160, 180


B Parallel shaft with key,
AS 14x9x70, DIN 6885

pN = 400 bar

pN = 350 bar

14/20

Size 160
P Parallel shaft with key,
AS 14x9x70, DIN 6885

pN = 350 bar

A2FO

RE 91 401/09.00

Unit Dimensions, Size 200


Before finalising your design, please request a certified drawing.

45

25

169

75
100

66,
7
32

21

M14; 19 deep

W 50x2x30x24x9g

pN = 400 bar

M16; 24 deep

Connections
B(A) Service line ports
SAE 1 1/4"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 3 1/2"
35 bar (500 psi) standard series
T
Drain port (1 port plugged)
M22x1,5
R
Air bleed (plugged)
M14x1,5

B Parallel shaft with key,


AS 14x9x70, DIN 6885

A Splined shaft, DIN 5480

69,9
108

265
319
341

Shaft ends

236

31,
8

92

102,5 25

121

15

90

B (A)

22

237

32

200 -0,029

45
236

15

120,7

40 32
9

211

104

Note:
For anti-clockwise rotation port
plate is rotated through 180

pN = 350 bar

Unit Dimensions, Size 250


Before finalising your design, please request a certified drawing.

45 0
3

82
22

45

246

118

T
22

124
246

28

B (A)

172

263

105

224 h8

B(A)

25

31,

105

82
103

50
9

Note:
For anti-clockwise rotation port
plate is rotated through 180

50,8
63
210

267

82

pN = 350 bar
A2FO

P Parallel shaft with key,


AS 14x9x80, DIN 6885

12
88,9

6
M1

309 M14; 19 deep


329

Shaft ends
Z Splined shaft, DIN 5480
W 50x2x30x24x9g

M12; 17 deep

32
66,
7

25

Connections
B(A) Service line ports
high pressure series
S
Suction port
standard series
T
Drain port (1 port plugged)
U
Port for bearing flushing (plugged)

SAE 1 1/4"
SAE 2 1/2"
M 22x1,5
M 14x1,5

pN = 350 bar
15/20

Brueninghaus Hydromatik

RE 91 401/09.00

Unit Dimensions, Size 355


Before finalising your design, please request a certified drawing.

320

335
36,6

18
M

83

102

MS

45

M12; 17 deep

M16; 21 deep
40

63
60

Connections
B(A) Service line ports
high pressure series
S
Suction port
standard series
T
Drain port (1 port plugged)
U
Port for bearing flushing (plugged)
MA (B) Gauge port (working pressure) plugged
MS
Gauge port (suction pressure) plugged

P Parallel shaft with key,


AS 18x11x100, DIN 6885

pN = 350 bar

50

250

350

Shaft ends
A Splined shaft, DIN 5480
W 60x2x30x28x9g

B (A)

198
28

MB

32

128

263

335

18

280 h8

79,4

36

88,9

245

45

T
128

50,8

83
23,5

170

50
14

Note:
For anti-clockwise rotation port
plate is rotated through 180

2230

SAE 1 1/2"
SAE 2 1/2"
M33x2
M14x1,5
M14x1,5
M14x1,5

pN = 350 bar

Unit Dimensions, Size 500


Before finalising your design, please request a certified drawing.

98
27,5

375

20

36,6

40

375

22
111

Brueninghaus Hydromatik

112,5

45

M16; 24 deep

M16; 24 deep
40
65
276

Shaft ends

pN = 350 bar

B (A)

396

Z Splined shaft, DIN 5480


W 70x3x30x22x9g

MS

36

220

142

2630

315 h8

30

106,4

MB
79,4

192

142

45

62
270

361,5
50
14

Note:
For anti-clockwise rotation port
plate is rotated through 180

22 30

P Parallel shaft with key,


AS 20x12x100, DIN 6885

Connections
B(A) Service line ports
high pressure series
S
Suction port
standard series
T
Drain port (1 port plugged)
U
Port for bearing flushing (plugged)
MA (B) Gauge port (working pressure) plugged
MS
Gauge port (suction pressure) plugged

75
55

SAE 1 1/2"
SAE 3"
M33x2
M18x1,5
M14x1,5
M14x1,5

pN = 350 bar
16/20

A2FO

RE 91 401/09.00

Unit Dimensions, Size 710


Before finalising your design, please request a certified drawing.

45

131
41,5

465

44,5

24
M

236

Note:
For anti-clockwise rotation port
plate is rotated through 180

2230

486
50
14

183

50

MB

MS

45

M16; 24 deep

M20; 30 deep
50

156

85

35

77,8
340

96,8

465

B (A)

45

252

183

102

1830

400 h8

22

130,2

100
70
344

507

Connections
B(A) Service line ports
high pressure series
S
Suction port
standard series
T
Drain port (1 port plugged)
U
Port for bearing flushing (plugged)
MA (B) Gauge port (working pressure) plugged
MS
Gauge port (suction pressure) plugged

Shaft ends
P Parallel shaft with key,
AS 25x14x125, DIN 6885

Z Splined shaft, DIN 5480


W 90x3x30x28x9g

pN = 350 bar

SAE 2"
SAE 4"
M42x2
M18x1,5
M14x1,5
M14x1,5

pN = 350 bar

Unit Dimensions, Size 1000


Before finalising your design, please request a certified drawing.

131
41,5

45

465

44,5

24

0
465

22
143

183

26 30

40 0 h8

pN = 350 bar
A2FO

M20; 30 deep

M16; 24 deep

50
85

100
70
344

512

Shaft ends
Z Splined shaft, DIN 5480
W 90x3x30x28x9g

B (A)

279

156

MS

45

35

130,2

MB
96,8

50

183

236

50
14

Note:
For anti-clockwise rotation port
plate is rotated through 180

2230

77,8
340

45

468

P Parallel shaft with key,


AS 25x14x125, DIN 6885

Connections
B(A) Service line ports
high pressure series
S
Suction port
standard series
T
Drain port (1 port plugged)
U
Port for bearing flushing (plugged)
MA (B) Gauge port (working pressure) plugged
MS
Gauge port (suction pressure) plugged

SAE 2"
SAE 4"
M42x2
M18x1,5
M14x1,5
M14x1,5

pN = 350 bar
17/20

Brueninghaus Hydromatik

RE 91 401/09.00

Preferred Types
Type

Ident-No.

Type

Ident-No.

A2F5.6.0B7

9404452

A2FO10/61R-PAB06
A2FO10/61R-PBB06

9424894
9610682

A2FO90/61R-PAB05
A2FO90/61R-PBB05

9408467
9408472

A2FO12/61R-PAB06
A2FO12/61R-PBB06

9420472
9610683

A2FO107/61R-PAB05
A2FO107/61R-PBB05

9423259
9438282

A2FO16/61R-PAB06
A2FO16/61R-PBB06

9411113
9411121

A2FO125/61R-PAB05
A2FO125/61R-PBB05

9409641
9409642

A2FO23/61R-PAB05
A2FO23/61R-PBB05

9427223
9610684

A2FO160/61R-PAB05
A2FO160/61R-PBB05

9422192
9610688

A2FO28/61R-PAB05
A2FO28/61R-PBB05

9425164
9610685

A2FO180/61R-PAB05
A2FO180/61R-PBB05

9409371
9409358

A2FO200/63R-PAB05

2011993

A2FO32/61R-PAB05
A2FO32/61R-PBB05

9410193
9410198

A2FO45/61R-PZB05

9411585

A2FO56/61R-PAB05
A2FO56/61R-PBB05

9425190
9610686

A2FO63/61R-PAB05
A2FO63/61R-PBB05

9408527
9408552

A2FO80/61R-PAB05
A2FO80/61R -PBB05

9424687
9610687

Sizes 5...200:
production Elchingen plant
Sizes 250...1000: production Horb plant
Please state type and ident-no. when ordering!

Brueninghaus Hydromatik

18/20

A2FO

RE 91 401/09.00

Installation and Commissioning Guidelines


General
At start-up and during operation the pump housing has imperatively
to be filled up with hydraulic fluid (filling of the case chamber). Startup has to be carried out at low speed and without load till the system
is completely bleeded.
At a longer standstill the case may discharge via operating line. At
new start-up a sufficient filling of the housing has to be granted.
The leakage oil in the housing has to be discharged to the tank via
highest positioned case drain port. The min. suction pressure at port
S should not fall below 0,8 bar absolute.
Installation position
Optional
Installation below tank level
Pumps below min. oil level in the tank (standard)
Fill up axial piston pump before start-up via highest positioned
case drain port (note for the shaft on top installation position:
fill until oil starts escaping from air bleed port R or U).

Installation on top of tank level


Pump on top of min. oil level in the tank
Actions as installation below tank level
Installation position 1 and 2:
If the pump is left at standstill for a long period, the oil in the
housing chamber may fully drain out through the operating
lines (air entering via the shaft seal). Consequently, on
restarting, the bearings will be insufficiently lubricated. You
should therefore refill the axial piston unit via the highest
positioned drain port before restarting (Installation position 2:
air bleed via port R or U).
Installation position 2 (shaft on top)
In this installation position, the bearings will be insufficiently
lubricated even if the housing chamber is only partially drained.
To prevent oil draining via the drain port, insert a check valve in
the drain line (opening pressure 0.5 bar).
Note: min. admissible presssure at port S (min. suction pressure)

Recommendation: Fill up suction lines


Operate pump at low speed (igniton speed) till pump system is
completely filled up

T1

S
T2

Minimum immersion depth of the suction line or drain line in


the tank:
200 mm (relative to the min. oil level in the tank).
S

T1

T2

T1

* *

0,5 bar

2
S

R(U)

T2

R (U)

T1
T2

A2FO

19/20

Brueninghaus Hydromatik

RE 91 401/09.00

Brueninghaus Hydromatik GmbH


Elchingen Plant
Glockeraustrae 2 D89275 Elchingen
Phone +49 (0) 73 08 82-0
Telefax +49 (0) 73 08 72 74

Horb Plant
An den Kelterwiesen 14 D72160 Horb
Phone +49 (0) 74 51 92-0
Telefax +49 (0) 74 51 82 21

Internet: www.rexroth.com/brueninghaushydromatik / E-Mail: [email protected]

All rights reserved Subject to revision

20/20

The specified data is for product description


purposes only and may not be deemed to be
guaranteed unless expressly confirmed in the
contract.

A2FO