Re91401 A2fo
Re91401 A2fo
Re91401 A2fo
00
RE 91 401/09.00
replaces: 01.97
A2FO
Index
Features
Ordering Code / Standard Program
Technical Data
Ordering Code - Size 5
Unit Dimensions, Size 5
Unit Dimensions, Sizes 10, 12, 16
Unit Dimensions, Sizes 23, 28, 32
Unit Dimensions, Size 45
Unit Dimensions, Sizes 56, 63
Unit Dimensions, Sizes 80, 90
Unit Dimensions, Sizes 107, 125
Unit Dimensions, Sizes 160, 180
Unit Dimensions, Size 200
Unit Dimensions, Size 250
Unit Dimensions, Size 355
Unit Dimensions, Size 500
Unit Dimensions, Size 710
Unit Dimensions, Size 1000
Preferred Types
Installation and Commissioning Guidelines
A2FO
Features
1
2
3...6
7
7
8
9
10
11
12
13
14
15
15
16
16
17
17
18
19
1/20
Brueninghaus
Hydromatik
RE 91 401/09.00
A2F
Hydraulic fluid
Mineral oil (no code)
HFB-, HFC-, HFDsizes 10...200 (no code)
fluids
sizes 250...1000 1)
/ 6
E-
A2F
Mode of operation
Pump, open circuit
Size
Displacement Vg (cm3)
5 10 12 16 23
28
32
45
56
63
80
90 107 125 160 180 200 250 355 500 710 1000
Sizes 5...200: production Elchingen plant; sizes 250...1000: production Horb plant
Series
6
Index
Direction of rotation
Viewed on shaft end
sizes 10...180
size 200
sizes 250...1000
1
3
0
clockwise
anti-clockwise
R
L
Seals
NBR (nitril-caoutchouc)
NBR (nitril-caoutchouc), shaft seal in FKM (fluor-caoutchouc)
FKM (fluor-caoutchouc)
Shaft end
Splined shaft
DIN 5480
Parallel shaft with
key, DIN 6885
10
Mounting flange 10
ISO 4-hole
ISO 8-hole
12
16
23
28
32
45
56
10...200 250...1000
63
80
90
107 125 160 180 200 250 355 500 710 1000
12
16
23
28
32
45
56
63
80
90
Brueninghaus Hydromatik
= available
= not available
B
H
05
06
2/20
A
Z
B
P
107 125 160 180 200 250 355 500 710 1000
= preferred program
(preferred types see page 18)
P
N
V
11
A2FO
RE 91 401/09.00
Technical Data
Fluid
To review the application of A2FO pumps with the selected hydraulic
fluid, detailed fluid compatibility and application data can be found
in data sheets RE 90220 (mineral oil), RE 90221 (environmentally
acceptable hydraulic fluids) and RE 90223 (fire resistant fluids, HF).
The fixed pump A2FO is not suitable for operation with HFA. When
using HFB-, HFC-, HFD- or environmentally acceptable hydraulic fluids
possible limitations for the technical data have to be taken into
consideration. If necessary please consult our technical department
(please indicate type of the hydraulic fluid used for your application
on the order sheet).
Operating viscosity range
In order to optain optimum efficiency and service life, we recommend
that the operating viscosity (at operating temperature) be selected
from within the range:
opt = operating viscosity 16...36 mm2/s
referred to the tank temperature (open circuit).
Viscosity limits
The limiting values for viscosity are as follows:
Sizes 5...200
min = 5 mm2/s,
short term at a max. permissible temperature of tmax = 115C
max = 1600 mm2/s,
short term on cold start (tmin = -40C)
Sizes 250...1000
min = 10 mm2/s,
short term at a max. permissible leakage oil temp. of tmax = 90
max = 1000 mm2/s,
short term on cold start (tmin = -25C)
Please note that the max. fluid temperature is also not exceeded in
certain areas (for instance bearing area).
At temperatures of -25C up to -40C special measures may be
required for certain installation positions. Please contact us for
further information.
Selection diagram
2500-40
1600
1000
600
400
-20
20
40
60
80 100
1600
60
40
36
opt.
20
Direction of flow
clockwise rotation
anti-clockwise rotation
S to B
S to A
Connections
A, B Service line ports
S
Suction port
T
Drain port
U Port for bearing flushing
(sizes 250...1000)
0
10
G
V 68
G
V 46
G
V 32
G
V 2
2
100
Filtration
The finer the filtration the better the achieved cleanliness level of the
pressure fluid and the longer the life of the axial piston unit.
To ensure the functioning of the axial piston unit a minimum
cleanliness level of
9 to NAS 1638
18/15 to ISO/DIS 4406 is necessary.
At very high temperatures of the hydraulic fluid (90C to max. 115C,
not permissible for sizes 2501000!) at least cleanliness level
8 to NAS 1638
17/14 to ISO/DIS 4406 is necessary.
If above mentioned grades cannot be maintained please consult
supplier.
Symbol
VG
200
viscosity (mm2/s)
16
B (A)
10
5
-40
-25
-10 0 10
30
50
70
90
5
115
temperature t (C)
tmin = -40C
A2FO
tmax = +115C
3/20
Brueninghaus Hydromatik
RE 91 401/09.00
Technical Data
Case drain pressure
Shaft seal ring FKM (fluor-caoutchouc)
The lower the speed and the case drain pressure the higher the life
expectation of the shaft seal ring. The values shown in the diagram
are permissible loads of the seal ring and shall not be exceeded.
With constant case pressure in the range of the max. permissible
case pressure a reduction of the life expectancy of the seal ring will
result.
For a short period (t < 5 min.) for the sizes 5200 pressure loads up
to 5 bar independent from rotational speeds are permissible.
Sizes 10...200
Size 5
Shaft end B
Shaft end C
Nominal pressure pN
210 bar
315 bar
250 bar
350 bar
Shaft end A, Z 2)
Shaft end B, P
Nominal pressure pN
400 bar
350 bar
450 bar
400 bar
10
Sizes 10...200 1)
8
7
size 45
sizes 80, 90
4
2
1
sizes 56, 63
Sizes 250...1000
size 200
0
1000
2000
3000
4000
5000
6000
7000
8000
speed n (rpm)
Sizes 250...1000
350 bar
400 bar
With pulsating loads above 315 bar we recommend using the model
with splined shaft, standard version A (sizes 10200) or with splined
shaft Z (sizes 2501000).
size 250
3,5
Nominal pressure pN
size 355
3
2,5
sizes 500
sizes 710
1,5
size 1000
1
0
250
500
750
1000
1250
1500
1750
2000
speed n (rpm)
Shaft seal ring NBR (nitril-caoutchouc) sizes 5...200
For seal rings of NBR 33% reduced values for the max. permissible
housing pressure pabs.max. are to be considered compared with seals
of FKM.
Special operation conditions may require limitations of these values.
Note:
- maximum permissible pump speeds are given in the table on page 5
- max. perm. casing pressure pabs. max ___ 10 bar (sizes 5...200)
___ 4 bar (sizes 250...1000)
- the pressure in the housing must be the same as or greater than
the external pressure on the shaft seal
Brueninghaus Hydromatik
250
355
500
710
1000
qflush (L/min)
10
16
20
25
25
4/20
A2FO
RE 91 401/09.00
Technical Data
Table of values (theoretical values, without considering mh and v; values rounded)
Size
Displacement
Max. speed 1)
Max. perm. speed with increased
input pressure pabs
Max. perm. output flow, at nmax2)
Max. power
p = 350 bar
at qv max
p = 400 bar
Torque constants
Perm. torque
p = 350 bar
p = 400 bar
Case volume
Moment of inertia
about drive axis
Weight (approx.)
10
12
16
23
28
32
45
56
63
80
Vg
nmax
cm3
rpm
4,93
5600
10,3
3150
12,0
3150
16,0
3150
22,9
2500
28,1
2500
32
2500
45,6
2240
56,1
2000
63 80,4
2000 1800
nmax perm.
rpm
8000
6000
6000
6000
4750
4750
4750
4250
3750
3750 3350
qV max
Pmax
Pmax
TK
T
T
L/min
kW
kW
Nm/bar
Nm
Nm
L
27
32
14,5 3) 19
22
0,076 0,164
24,7 3) 57
65
0,17
37
22
25
0,19
67
76
0,17
49
29
34
0,25
88
100
0,17
56
33
38
0,36
126
144
0,20
68
78
99
41
47
60
47
53
68
0,445 0,509 0,725
156
178
254
178
204
290
0,20 0,20 0,33
109
65
75
0,89
312
356
0,45
122
74
84
1,0
350
400
0,45
kgm2
0,00008 0,0004
0,0004
0,0004
0,0012
0,0012
0,0012
0,0024
0,0042
0,0042 0,0072
kg
Vg
nmax
cm
rpm
nmax perm.
140
84
96
1,27
445
508
0,55
2,5
5,4
5,4
5,4
9,5
9,5
9,5
13,5
18
90
107
1 25
160
180
200
250
355
500
710 1000
90 106,7
1800 1600
200
1550
250
1500
355
1320
500
1200
710 1000
1200 950
rpm
3350
3000
3000
2650
2650
2750
1800
1600
1500
1500 1200
qV max
Pmax
Pmax
TK
T
T
L/min
kW
kW
Nm/bar
Nm
Nm
L
158
95
108
1,43
501
572
0,55
167
100
114
1,70
595
680
0,8
196
117
133
1,99
697
796
0,8
228
135
155
2,55
889
1016
1,1
255
152
174
2,86
1001
1144
1,1
304
181
207
3,18
1114
1272
364
219
3,99
1393
2,5
455
273
5,65
1978
3,5
582
350
7,96
2785
826 922
497 554
11,3 15,9
3955 5570
7,8
kgm2
kg
Size
Displacement
Max. speed 1)
Max. perm. speed with increased
input pressure pabs
Max. perm. output flow, at nmax2)
Max. power
p = 350 bar
at qv max
p = 400 bar
Torque constants
Perm. torque
p = 350 bar
p = 400 bar
Case volume
Moment of inertia
about drive axis
Weight (approx.)
32
32
45
45
66
73
110
155
18
23
0,55
0,55
322
336
) The values shown are valid for an absolute pressure (pabs) of 1 bar at the suction inlet S and when operated on mineral oil.
By increase of the input pressure (pabs > 1 bar) the rotational speeds can be increased to the max. admissible speeds (speed limits) (see diagram).
) p = 315 bar
qV =
Torque
T=
Power
P = 2 T n = T n = qV p
60 000
9549 600 t
sizes 250...1000
sizes 5...200
0,8
1,0
1,2
1,4
1,6
Note:
- max. perm. speed nmax perm. (speed limit)
- min. perm. pressure at port S
- admissible values for the drive shaft seal
1,8
2,0
speed n/nmax
Vg n v
1000
Flow
A2FO
Calculation of size
Vg =
T =
p =
n =
v =
mh=
t =
5/20
Vg p
20 mh
in L/min
1,59 Vg p
100 mh
in Nm
in kW
in cm3
in Nm
in bar
in rpm
Brueninghaus Hydromatik
RE 91 401/09.00
Technical Data
Output drive
Permissible axial and radial loads on drive shaft
The values given are maximum values and do not apply to continuous operation
Size
10
12
16
23
28
32
45
56
63
80
mm
12
16
16
16
16
16
16
18
18
18
20
Fq max
710
2350
2750
3700
4300
5400
6100
8150
9200
10300
11500
Fax max
180
320
320
320
500
500
500
630
800
800
1000
Fax perm./bar
N/bar
1,5
3,0
3,0
3,0
5,2
5,2
5,2
7,0
8,7
8,7
10,6
90
107
125
160
180
200
250
355
500
710
1000
20
20
20
25
25
25
41
52,5
52,5
67,5
67,5
Size
a
mm
Fq max
12900
13600
15900
18400
20600
22900
12001)
15001)
19001)
30001)
26001)
Fax max
1250
1250
1600
1600
1600
4000
5000
6250
10000
10000
1000
1250
1250
1600
1600
1600
1200
1500
1900
3000
2600
10,6
12,9
12,9
16,7
16,7
16,7
- Fax max
Fax perm./bar
1
2
N/bar
) Axial piston unit in stationary or in bypass operation, please contact us when appearing higher forces!
) Please contact us!
Code explanation
Fq
a
= distance of Fq from shaft shoulder
Fq max
= max. perm. radial force at distance a
(at intermittent operation)
a
Fax max
= max. perm. axial force when stationary
or when axial piston unit is running at zero pressure
Fax perm./bar= perm. axial force/bar working pressure
pt
op
=4
5
=7
pt
o
= 45
clockwise rotation
pressure at port B
anti-clockwise rotation
pressure at port A
Brueninghaus Hydromatik
clockwise rotation
pressure at port B
6/20
A2FO
RE 91 401/09.00
A2F 5
Axial piston unit
Bent axis design, fixed displacement
6.0
A2F
Additional instructions in text form
Size
Displacement Vg (cm3)
Direction of rotation
Viewed on shaft end
clockwise
anti-clockwise
Seals
The fixed pump A2F 5 is equipped with NBR(nitril-caoutchouc) seals in standard design.
In case of need FKM- (fluor-caoutchouc) seals
please indicate when ordering in clear text:
"with FKM-seals"
R
L
Series
6.0
Shaft end
Parallel shaft with key DIN 6885
Tapered shaft with spigot and spring washer DIN 6888
B
C
= preferred program
(preferred types see page 18)
Note:
For anti-clockwise rotation port
plate is rotated through 180
Detail Y
70
74,
5
5
62
48,5
6,4
25
0,1
75
4
51
70
60 h8
R6
58,
17,
80
B (A)
Connections
B, (A) Service line ports
S
Suction port
T
Drain port
Shaft ends
B Parallel shaft with
key A4x4x20
DIN 6885
M18x1,5
M22x1,5
M10x1, both sides
taper 1:10
pN = 210 bar
A2FO
pN = 315 bar
7/20
Brueninghaus Hydromatik
RE 91 401/09.00
Note:
For anti-clockwise rotation port
plate is rotated through 180
64,5
45
T1
20 12
6
45
95
5
B (A)
R 10
10
18,2
85
95
,5
41
10
23,5
55,5
69
93,5
53,5
48,5
40
80 h6
42,5
16
T2
130,5
147
167,5
Connections
B(A) Service line ports
S
Suction port
T1,T2 Drain port (1 port plugged)
R
Air bleed (plugged)
M22x1,5
M33x2
M12x1,5
M8x1
Shaft ends
Sizes 10, 12, 16
A Splined shaft, DIN 5480
W 25x1,25x30x18x9g
pN = 400 bar
Brueninghaus Hydromatik
Sizes 10, 12
Z Splined shaft, DIN 5480
W 20x1,25x30x14x9g
pN = 400 bar
pN = 350 bar
8/20
Sizes 10, 12
P Parallel shaft with key,
AS 6x6x32, DIN 6885
pN = 350 bar
A2FO
RE 91 401/09.00
Note:
For anti-clockwise rotation port
plate is rotated through 180
60,7
25 18
8
45
T1
118
23,2
B (A)
R 12
47,6
19
14
T2
106
118
12
,2
11
40 48,
5
13 ,5
18
70
91
120
55,5
61,5
40
19
S
22,2
19
100 h6
45
60
14
M10; 17 deep
144
169
193
M8; 15 deep
Connections
B(A) Service line ports
SAE 1/2"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 3/4"
350 bar (5000 psi) standard series
T1,T2 Drain port (1 port plugged)
M16x1,5
R
Air bleed (plugged)
M10x1
Shaft ends
Sizes 23, 28, 32
A Splined shaft, DIN 5480
W 30x2x30x14x9g
pN = 400 bar
A2FO
Sizes 23, 28
Z Splined shaft, DIN 5480
W 25x1,25x30x18x9g
pN = 400 bar
pN = 350 bar
9/20
Sizes 23, 28
P Parallel shaft with key,
AS 8x7x40, DIN 6885
pN = 350 bar
Brueninghaus Hydromatik
RE 91 401/09.00
Note:
For anti-clockwise rotation port
plate is rotated through 180
60,3
45
T1
R 16
25
S
26,2
B (A)
11
16
,8
118
23
150
52
15
8
50
19 ,8
63
78
40
125 h6
18
52,4
13,5
18
30
45
150
80
102
132
32 20
12
63,5
20
M10; 17 deep
T2
155
181
206
M10; 17 deep
Connections
B(A) Service line ports
SAE 3/4"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 1"
350 bar (5000 psi) standard series
T1,T2 Drain port (1 port plugged)
M18x1,5
R
Air bleed (plugged)
M12x1,5
Shaft ends
A Splined shaft, DIN 5480
W 32x2x30x14x9g
pN = 400 bar
Brueninghaus Hydromatik
pN = 400 bar
pN = 350 bar
10/20
A2FO
RE 91 401/09.00
Note:
For anti-clockwise rotation port
plate is rotated through 180
45
T1
45
150
18
30
R 16
16
B (A)
52,4
25
150
128
16
13,5
56
11
23
,8
87
109
142
50
19 ,8
78
70
40
125 h6
9,
18
S
26,2
67,5
32 20
10
23
68
M10; 17 deep
T2
171
197
225
M10; 17 deep
Connections
B(A) Service line ports
SAE 3/4"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 1"
350 bar (5000 psi) standard series
T1,T2 Drain port (1 port plugged)
M18x1,5
R
Air bleed (plugged)
M12x1,5
Shaft ends
Sizes 56, 63
A Splined shaft, DIN 5480
W 35x2x30x16x9g
pN = 400 bar
A2FO
Size 56
Z Splined shaft, DIN 5480
W 30x2x30x14x9g
Sizes 56, 63
B Parallel shaft with key,
AS 10x8x50, DIN 6885
pN = 350 bar
pN = 350 bar
11/20
Size 56
P Parallel shaft with key,
AS 8x7x50, DIN 6885
pN = 350 bar
Brueninghaus Hydromatik
RE 91 401/09.00
Note:
For anti-clockwise rotation port
plate is rotated through 180
45
T1
165
9,
11
18
,8
138
61
57
,2
25
15
B (A)
99
122
160
32
R 16
18
27
83
85,5
40
140 h6
29
58,7
30,2
15
45
13,5
165
78,5
32 20
10
73
25
M10; 17 deep
T2
196
223,5
255
M12; 17 deep
Connections
B(A) Service line ports
SAE 1"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 1 1/4"
280 bar (4000 psi) standard series
T1,T2 Drain port (1 port plugged)
M18x1,5
R
Air bleed (plugged)
M12x1,5
Shaft ends
Sizes 80, 90
A Splined shaft, DIN 5480
W 40x2x30x18x9g
pN = 400 bar
Brueninghaus Hydromatik
Size 80
Z Splined shaft, DIN 5480
W 35x2x30x16x9g
Sizes 80, 90
B Parallel shaft with key,
AS 12x8x56, DIN 6885
pN = 400 bar
pN = 350 bar
12/20
Size 80
P Parallel shaft with key,
AS 10x8x56, DIN 6885
pN = 350 bar
A2FO
RE 91 401/09.00
Note:
For anti-clockwise rotation port
plate is rotated through 180
45
T1
66
20
,8
12
190
89
T2
S
150
27
69,9
38
35,7
B (A)
21
2
31
,8
(
136
173
,7
6
32 (5 7 7
(2 ,2 )
5)
85
40
160 h6
98
18
45
R 20
110
18
36,5
190
17,5
82,8
23
40
10
20
M12; 20 deep
213
245
275
M14; 19 deep
(M12; 17 deep)
Connections
B(A) Service line ports
SAE 1 1/4" (1")
420 bar (6000 psi) high pressure series
S
Suction port
SAE 1 1/2"
210 bar (3000 psi) standard series
T1,T2 Drain port (1 port plugged)
M18x1,5
R
Air bleed (plugged)
M14x1,5
Shaft ends
Sizes 107, 125
A Splined shaft, DIN 5480
W 45x2x30x21x9g
pN = 400 bar
A2FO
Size 107
Z Splined shaft, DIN 5480
W 40x2x30x18x9g
pN = 400 bar
pN = 350 bar
13/20
Size 107
P Parallel shaft with key,
AS 12x8x63, DIN 6885
pN = 350 bar
Brueninghaus Hydromatik
RE 91 401/09.00
Note:
For anti-clockwise rotation port
plate is rotated through 180
45
210
T1
32
22
,8
180
210
31
S
35,7
69,9
42
12,5
T2
B (A)
150
188
23
77
,5
,5
,7
19,5
66
95,5
108
40
180 h6
37,2
R 20
121
19
45
17,5
93
40 25
10
101
15
M12; 20 deep
237
271
294
M14; 19 deep
Connections
B(A) Service line ports
SAE 1 1/4"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 1 1/2"
210 bar (3000 psi) standard series
T1,T2 Drain port (1 port plugged)
M22x1,5
R
Air bleed (plugged)
M14x1,5
Shaft ends
Sizes 160, 180
A Splined shaft, DIN 5480
W 50x2x30x24x9g
pN = 400 bar
Brueninghaus Hydromatik
Size 160
Z Splined shaft, DIN 5480
W 45x2x30x21x9g
pN = 400 bar
pN = 350 bar
14/20
Size 160
P Parallel shaft with key,
AS 14x9x70, DIN 6885
pN = 350 bar
A2FO
RE 91 401/09.00
45
25
169
75
100
66,
7
32
21
M14; 19 deep
W 50x2x30x24x9g
pN = 400 bar
M16; 24 deep
Connections
B(A) Service line ports
SAE 1 1/4"
420 bar (6000 psi) high pressure series
S
Suction port
SAE 3 1/2"
35 bar (500 psi) standard series
T
Drain port (1 port plugged)
M22x1,5
R
Air bleed (plugged)
M14x1,5
69,9
108
265
319
341
Shaft ends
236
31,
8
92
102,5 25
121
15
90
B (A)
22
237
32
200 -0,029
45
236
15
120,7
40 32
9
211
104
Note:
For anti-clockwise rotation port
plate is rotated through 180
pN = 350 bar
45 0
3
82
22
45
246
118
T
22
124
246
28
B (A)
172
263
105
224 h8
B(A)
25
31,
105
82
103
50
9
Note:
For anti-clockwise rotation port
plate is rotated through 180
50,8
63
210
267
82
pN = 350 bar
A2FO
12
88,9
6
M1
Shaft ends
Z Splined shaft, DIN 5480
W 50x2x30x24x9g
M12; 17 deep
32
66,
7
25
Connections
B(A) Service line ports
high pressure series
S
Suction port
standard series
T
Drain port (1 port plugged)
U
Port for bearing flushing (plugged)
SAE 1 1/4"
SAE 2 1/2"
M 22x1,5
M 14x1,5
pN = 350 bar
15/20
Brueninghaus Hydromatik
RE 91 401/09.00
320
335
36,6
18
M
83
102
MS
45
M12; 17 deep
M16; 21 deep
40
63
60
Connections
B(A) Service line ports
high pressure series
S
Suction port
standard series
T
Drain port (1 port plugged)
U
Port for bearing flushing (plugged)
MA (B) Gauge port (working pressure) plugged
MS
Gauge port (suction pressure) plugged
pN = 350 bar
50
250
350
Shaft ends
A Splined shaft, DIN 5480
W 60x2x30x28x9g
B (A)
198
28
MB
32
128
263
335
18
280 h8
79,4
36
88,9
245
45
T
128
50,8
83
23,5
170
50
14
Note:
For anti-clockwise rotation port
plate is rotated through 180
2230
SAE 1 1/2"
SAE 2 1/2"
M33x2
M14x1,5
M14x1,5
M14x1,5
pN = 350 bar
98
27,5
375
20
36,6
40
375
22
111
Brueninghaus Hydromatik
112,5
45
M16; 24 deep
M16; 24 deep
40
65
276
Shaft ends
pN = 350 bar
B (A)
396
MS
36
220
142
2630
315 h8
30
106,4
MB
79,4
192
142
45
62
270
361,5
50
14
Note:
For anti-clockwise rotation port
plate is rotated through 180
22 30
Connections
B(A) Service line ports
high pressure series
S
Suction port
standard series
T
Drain port (1 port plugged)
U
Port for bearing flushing (plugged)
MA (B) Gauge port (working pressure) plugged
MS
Gauge port (suction pressure) plugged
75
55
SAE 1 1/2"
SAE 3"
M33x2
M18x1,5
M14x1,5
M14x1,5
pN = 350 bar
16/20
A2FO
RE 91 401/09.00
45
131
41,5
465
44,5
24
M
236
Note:
For anti-clockwise rotation port
plate is rotated through 180
2230
486
50
14
183
50
MB
MS
45
M16; 24 deep
M20; 30 deep
50
156
85
35
77,8
340
96,8
465
B (A)
45
252
183
102
1830
400 h8
22
130,2
100
70
344
507
Connections
B(A) Service line ports
high pressure series
S
Suction port
standard series
T
Drain port (1 port plugged)
U
Port for bearing flushing (plugged)
MA (B) Gauge port (working pressure) plugged
MS
Gauge port (suction pressure) plugged
Shaft ends
P Parallel shaft with key,
AS 25x14x125, DIN 6885
pN = 350 bar
SAE 2"
SAE 4"
M42x2
M18x1,5
M14x1,5
M14x1,5
pN = 350 bar
131
41,5
45
465
44,5
24
0
465
22
143
183
26 30
40 0 h8
pN = 350 bar
A2FO
M20; 30 deep
M16; 24 deep
50
85
100
70
344
512
Shaft ends
Z Splined shaft, DIN 5480
W 90x3x30x28x9g
B (A)
279
156
MS
45
35
130,2
MB
96,8
50
183
236
50
14
Note:
For anti-clockwise rotation port
plate is rotated through 180
2230
77,8
340
45
468
Connections
B(A) Service line ports
high pressure series
S
Suction port
standard series
T
Drain port (1 port plugged)
U
Port for bearing flushing (plugged)
MA (B) Gauge port (working pressure) plugged
MS
Gauge port (suction pressure) plugged
SAE 2"
SAE 4"
M42x2
M18x1,5
M14x1,5
M14x1,5
pN = 350 bar
17/20
Brueninghaus Hydromatik
RE 91 401/09.00
Preferred Types
Type
Ident-No.
Type
Ident-No.
A2F5.6.0B7
9404452
A2FO10/61R-PAB06
A2FO10/61R-PBB06
9424894
9610682
A2FO90/61R-PAB05
A2FO90/61R-PBB05
9408467
9408472
A2FO12/61R-PAB06
A2FO12/61R-PBB06
9420472
9610683
A2FO107/61R-PAB05
A2FO107/61R-PBB05
9423259
9438282
A2FO16/61R-PAB06
A2FO16/61R-PBB06
9411113
9411121
A2FO125/61R-PAB05
A2FO125/61R-PBB05
9409641
9409642
A2FO23/61R-PAB05
A2FO23/61R-PBB05
9427223
9610684
A2FO160/61R-PAB05
A2FO160/61R-PBB05
9422192
9610688
A2FO28/61R-PAB05
A2FO28/61R-PBB05
9425164
9610685
A2FO180/61R-PAB05
A2FO180/61R-PBB05
9409371
9409358
A2FO200/63R-PAB05
2011993
A2FO32/61R-PAB05
A2FO32/61R-PBB05
9410193
9410198
A2FO45/61R-PZB05
9411585
A2FO56/61R-PAB05
A2FO56/61R-PBB05
9425190
9610686
A2FO63/61R-PAB05
A2FO63/61R-PBB05
9408527
9408552
A2FO80/61R-PAB05
A2FO80/61R -PBB05
9424687
9610687
Sizes 5...200:
production Elchingen plant
Sizes 250...1000: production Horb plant
Please state type and ident-no. when ordering!
Brueninghaus Hydromatik
18/20
A2FO
RE 91 401/09.00
T1
S
T2
T1
T2
T1
* *
0,5 bar
2
S
R(U)
T2
R (U)
T1
T2
A2FO
19/20
Brueninghaus Hydromatik
RE 91 401/09.00
Horb Plant
An den Kelterwiesen 14 D72160 Horb
Phone +49 (0) 74 51 92-0
Telefax +49 (0) 74 51 82 21
20/20
A2FO