Ecodry - 3DK: Adiabatic Cooler

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Ecodry - 3DK

Adiabatic Cooler
Water Conservation is a MUST
The growing global scarcity of water had inspire us to
design ECODRY: the most efficient Adiabatic Cooler
available today. In fact, extremely large amounts of
fresh water are consumed everyday caused by
“evaporative” heat rejection of Cooling Towers.
The use of this new technology may save up to 95% of
it. Water cost is also increasingly becoming an important
economic factor when operating a Cooling Tower, but is
not the only one.
A large list of advantages makes this new technology an
unbeatable alternative to them, achieving:
 better cooling performance with increased heat
transfer efficiency;
 outstanding operating costs savings, resulting in a
low total cost of ownership;
 new standards in terms of Environmental Impact,
from both water footprint and total emissions.
Ecodry is an Adiabatic Cooler. It is installed outdoors in
order to reject to ambient the heat extracted from pro-
cesses, providing precise cooling conditions even in ex-
treme ambient temperatures (up to 50°C) delivering
clean water at the right temperature year round with
unbeatable efficiency.

Main features
The Adiabatic Cooler ECODRY combines:
Dry Cooler
 Low pressure loss heat exchangers with high performance copper/aluminum finned coil and
stainless steel headers
 Axial fans in die-cast aluminum, with individual inverter driven brushless EC (variable speed fan
motors) or EZ (brushless variable speed fan motors with exhaust diffusers) motors
 Self-Draining by gravity coil configuration for glycol-free operation
 Stainless steel frame and support structure and aluminum access panels
Adiabatic chamber
 Unique Adiabatic Chamber (internationally patented) enclosed with cellulose pads and
equipped with high efficiency air humidification spray nozzles, designed for air pre-cooling
based on variable flow of a thin water mist

Intelligent Control System


 PLC hardware based on digital control and on-demand managing logics of the entire system
 Fan speed management: system always delivers the minimum air flow required, according to real load demand and actual ambient
temperature
 Dry – Adiabatic – Booster switch: system automatically commutates from one mode to the other according to real load demand
and actual ambient temperature
 Water consumption management in Adiabatic Mode controls water evaporation according to the real demand
 Process pump management: system automatically controls the actual pumping capacity according to the real demand of process
water flow
 Complete set of sensors and anti-freeze self-draining software
Structure
 The metal structure is in AISI430 stainless steel. If there are particular applications in areas where the atmosphere is somewhat
corrosive for steel in order to avoid possible presence of rust stains, it is recommended to request a specific surface structures
and/or treatment

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Advantages

Lower Water Consumption

 High humidification efficiency of sprayed mist of water in the “adiabatic


chamber”
 Lower approach to WB of precooled air with less water usage
 Proven performance in extreme weather conditions, up to 50°C
 Intelligent Management System automatically adjusts the lowest water con-
sumption according to actual conditions
Lower Energy Consumption

 Unbeatable efficiency with Electronically Commutated (EC) fans as standard


 Reduced fan consumption through low air pressure drop cellulose pads
 Easy removal of pads during DRY operation periods
 Less pumping energy consumption thanks to low coil pressure losses
 Less pumping losses caused by filtering of process water flow
 Free Cooling: the same system may have ability to automatically replace, par-
tially or totally, “mechanical refrigeration systems” operating as a dry-cooler
during winter time
Lower Maintenance Costs

 Minimal ongoing water treatment and filtration required (except for high
concentrations of limestone)
 No risk of coil corrosion and scaling - coils are always kept completely dry
 Extended life of humidifying pads thanks to water nebulization instead of
being soaked with water
 Extended legs to avoid dust intake
 Maintenance-free fan motors
 Easy access for cleaning of coils and adiabatic chamber

Glycol-Free Operation

 100% reliability in extreme weather conditions down to -40°C


 Better heat transfer efficiency
 Less environmental impact
 Less pumping energy consumption

Clean Water to Processes

 Close loop circuit - guarantees always uncontaminated clean water to pro-


cess
 No surface fouling, constant efficiency of heat transfer with processes
 Minimal ongoing chemical treatment required

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Advantages
Compact Design

 Optimized shipping dimensions


 Air intake from underneath
 Favourable capacity/footprint ratio with 35% less
footprint required between units
 No air flow recirculation between units

Total Modularity, High Reliability & 100% Rust-Free

 Easy to expand at anytime to meet growing needs


 Electrical redundancy with individually wired fans
 Reduced installation costs - preassembled stainless
steel manifolds for interconnection
 Stainless steel structural frame and aluminum pan-
els
 Copper coils and aluminum fins with hydrophilic
protection
 Rigid structure, resistant to deflection - high level of
static stability

Intelligent Management System

 Control guarantees an efficient operation and com-


pliance with the predicted consumption values
 The control continually monitors all the significant
parameters and automatically adapts the operating
mode to the current system requirements
 Intelligent control of fan speed and wetting
 Complete set of sensors and anti-freezing software
 Siemens PLC hardware to manage the entire system
from a single location
 External communication via Modbus RTU over
Ethernet TCP/IP network
 Preventive maintenance and failure pinpointing
 Remote web monitoring connection
 Allows Frigel service technicians to monitor and
troubleshoot from locations worldwide
 Communication with building management systems
 Easy to install, supplied ready for connection
 Compact, adaptable and expandable

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Operating Principles
Dry Mode
The unit operates like a conventional finned dry cooler. Heat is dissipated to the ambient air via convection.
The speed control of EC fan motors keeps coolant at a pre-programmed minimum setpoint, saving energy.
During long winter periods, accessing panels may be removed, in order to improve air flow and reduce even
more the fan energy consumption.
Adiabatic mode
During high ambient temperature conditions, thanks to
the Adiabatic Chamber and an Intelligent Management
Control System, the coolant temperature is kept at a
pre-programmed maximum setpoint.
 The ambient air at high temperature passes through
the “adiabatic chamber”
 In the chamber, spray nozzles create a thin mist of
water from an external source
 The humidification of the air drops its temperature
before it reaches the coils
 The amount of water consumed is automatically con-
trolled by microprocessor
 To ensure consistent cooling, the control system con-
tinuously adjusts the amount of water sprayed
 Chamber design avoids water drift outside the cham-
ber preventing heat exchanger scaling

Booster mode
 Available adiabatic booster for situations where set
point cannot be maintained due to extremely high
ambient temperatures and/or where an extremely
low temperature is required (typically less than 30°C)
 With the adiabatic chamber in full operation, the 3PR
control system will sequentially activate solenoid
valves to completely flood of the coil surfaces
 Unlike other systems, this flooding process prevents
evaporation on the coil surfaces
 The coils are coated with hydrophilic paint to addi-
tionally prevent pitting of the surfaces
 Normally the booster system is used as an emergen-
cy for a few hours of the year
 Continuous and Homogeneous Waterfall on Hydro-
philic Coated Exchangers; typical operating situation:
 INLET: 100 litres of water with 10 g of calcium carbonate
(hardness 10°F)
 OUTLET: 30 litres of water into the exhaust air (useful ef-
fect), 70 litres of water + 10 g of calcium carbonate dropping
in the adiabatic chamber (adiabatic useful effect), 0 g of cal-
cium carbonate on the exchanger’s fins

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Operating Principles

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Options

Special Epoxy Coil Coating


 Polyurethane heat exchanger coil coating to pro-
vide an even higher level of protection in adverse
climate conditions
 Life of these heat exchangers can be significantly
increased by using epoxy-coated fins for higher
strength and chemical resistance

Fan Exhaust Diffusers


 Prevent exhaust air flow from being drawn back
into the adiabatic chamber at the bottom of the
unit
 Reduce significantly noise emissions

Roof Panels
 Avoids exhaust air from recirculating between
units down into the adiabatic chamber
 The panels allow multiple units to be positioned
closely together

Extended Legs
 Extended legs can easily raise the units to facili-
tate airflow from underneath in tight spaces
 Simplifies pitch installation for “Self-Draining Con-
figuration”

Self-Draining Configuration (Glycol-Free Opera-


tion)
 Automatic self-draining by gravity with no valves
or moving parts
 Complete set of sensors and anti-freezing soft-
ware
 Special anti-freeze stainless steel preassembled
manifolds

Integrated Pump Station


 Design according to actual requirements and engi-
neered for easy modular growth for future expan-
sions
 Preassembled and factory tested before shipping
 Stainless steel reservoirs and stainless steel filters
 Self-draining configuration optimizes performance
involving non-glycol applications in freezing cli-
mates

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Parallel Coil Configuration (P)
Glycol system or water system (no glycol) in non-freezing climates
Sound level
Power input VictaulicTM Approximate weights dB(A) @10 m Dimensions (mm) (*)
Fans Internal
Total Connections
Model Rows per EC fans EZ fans volume C C
fans mm (in) Shipping Operating EC Ez
row per unit per unit liter A B C (**) (+40) (+84)
(***) kg (****) kg (*****) fan fan
(kW) (kW) (**) (**)
3DK11P 1 1 1 2,10 1,75 DN100 (4) 70 365 500 51 49 1.127 2.523 2.923 3.323 -

3DK21P 1 2 2 4,20 3,50 DN100 (4) 120 565 700 54 52 1.127 3.643 2.923 3.323 -

3DK31P 1 3 3 6,30 5,25 DN100 (4) 140 725 900 56 54 1.127 4.743 2.923 3.323 -

3DK41P 1 4 4 8,30 7,00 DN150 (6) 160 940 1.200 57 55 1.127 5.902 2.929 3.329 -

3DK51P 1 5 5 10,50 8,75 DN150 (6) 180 1.145 1.400 58 56 1.127 7.020 2.929 3.329 3.769

3DK71P 1 7 7 14,70 12,25 DN200 (8) 255 1.630 1.900 60 58 1.127 9.225 2.987 3.387 3.827

3DK101P 1 10 10 21,00 17,50 DN200 (8) 350 2.275 2.700 61 59 1.127 12.525 2.987 3.387 3.827

3DK22P 2 2 4 8,40 7,00 DN100 (4) 235 1.040 1.300 57 55 2.235 3.643 2.923 3.323 -

3DK32P 2 3 6 12,60 10,50 DN100 (4) 275 1.285 1.600 59 57 2.235 4.743 2.923 3.323 -

3DK42P 2 4 8 16,80 14,00 DN150 (6) 315 1.640 2.000 60 58 2.235 5.902 2.929 3.329 -

3DK52P 2 5 10 21,00 17,50 DN150 (6) 360 1.970 2.400 61 59 2.235 7.020 2.929 3.329 3.769

3DK72P 2 7 14 29,40 24,50 DN200 (8) 510 2.815 3.400 62 60 2.235 9.225 2.987 3.387 3.827

3DK102P 2 10 20 42,00 35,00 DN200 (8) 700 3.895 4.700 64 62 2.235 12.525 2.987 3.387 3.827
Power supply voltage and frequency: 380-480±10%/3/50-60Hz
Do NOT use the data in this document for construction purposes. Specifications are subject to change without notice.
Max working temperature: 10 bar
(*) Extended support leg requirements (+40 cm or +84 cm) are determined by Frigel.
(**) Add 28 mm for models with EZ fans (21, 22, 31, 32, 41, 42, 51 & 52
(***) Adiabatic chamber spray connections: 1" GAS-F per row. Unused connections must be plugged. Adiabatic chamber drain connections: 1” hose barb.
(****) This is also the approximate rigging weight, excluding the additional weight of the optional extended support legs.
(*****) Operating weights do not include external flooded piping or support steel structures.

Application diagram
Ecodry P version
with pumping station in
serial communication

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Series Coil Configuration (S)
Glycol system or water system (no glycol) in non-freezing climates
Sound level
Power input VictaulicTM Approximate weights dB(A) @10 m Dimensions (mm) (*)
Fans Internal
Total Connections
Model Rows per EC fans EZ fans volume C C
fans mm (in) Shipping Operating EC Ez
row per unit per unit liter A B C (**) (+40) (+84)
(***) kg (****) kg (*****) fan fan
(kW) (kW) (**) (**)
3DK11S 1 1 1 2,10 1,75 DN65 (2½) 70 320 400 51 49 1.127 1.722 2.925 3.325 -

3DK21S 1 2 2 4,20 3,50 DN100 (4) 120 565 700 54 52 1.127 3.322 2.925 3.325 -

3DK31S 1 3 3 6,30 5,25 DN100 (4) 140 735 900 56 54 1.127 4.422 2.925 3.325 -

3DK41S 1 4 4 8,30 7,00 DN150 (6) 160 940 1.200 57 55 1.127 5.580 2.925 3.325 -

3DK51S 1 5 5 10,50 8,75 DN150 (6) 180 1.205 1.400 58 56 1.127 6.680 2.925 3.325 3.765

3DK71S 1 7 7 14,70 12,25 DN200 (8) 255 1.630 1.900 60 58 1.127 8.924 2.925 3.325 3.765

3DK101S 1 10 10 21,00 17,50 DN200 (8) 350 2.270 2.700 61 59 1.127 12.224 2.925 3.325 3.765

3DK22S 2 2 4 8,40 7,00 DN100 (4) 235 1.040 1.300 57 55 2.235 3.322 2.925 3.325 -

3DK32S 2 3 6 12,60 10,50 DN100 (4) 275 1.195 1.500 59 57 2.235 4.422 2.925 3.325 -

3DK42S 2 4 8 16,80 14,00 DN150 (6) 315 1.655 2.000 60 58 2.235 5.580 2.925 3.325 -

3DK52S 2 5 10 21,00 17,50 DN150 (6) 360 1.965 2.400 61 59 2.235 6.680 2.925 3.325 3.765

3DK72S 2 7 14 29,40 24,50 DN200 (8) 510 2.830 3.400 62 60 2.235 8.924 2.925 3.325 3.765

3DK102S 2 10 20 42,00 35,00 DN200 (8) 700 3.895 4.700 64 62 2.235 12.224 2.925 3.325 3.765
Power supply voltage and frequency: 380-480±10%/3/50-60Hz
Do NOT use the data in this document for construction purposes. Specifications are subject to change without notice.
Max working temperature: 10 bar
(*) Extended support leg requirements (+40 cm or +84 cm) are determined by Frigel.
(**) Add 52 mm for models with EZ fans (11, 21, 22, 31 & 32). Add 36 mm for models with EC fans (41, 42, 51 & 52).
(***) Adiabatic chamber spray connections: 1" GAS-F per row. Unused connections must be plugged. Adiabatic chamber drain connections: 1” hose barb.
(****) This is also the approximate rigging weight, excluding the additional weight of the optional extended support legs.
(*****) Operating weights do not include external flooded piping or support steel structures.

Application diagram
Ecodry S version
with pumping station in
serial communication

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Self-Draining Configuration (D)
Water system (no glycol) with recirculation pump stations for freezing climates
Sound level
Power input VictaulicTM Approximate weights dB(A) @10 m Dimensions (mm) (*)
Fans Internal
Total Connections
Model Rows per EC fans EZ fans volume C C
fans mm (in) Shipping Operating EC Ez
row per unit per unit liter A B C (**) (+40) (+84)
(***) kg (****) kg (*****) fan fan
(kW) (kW) (**) (**)
3DK21D 1 2 2 4,20 3,50 DN150 (6) 120 605 800 54 52 1.127 3.607 3.019 3.419 -

3DK31D 1 3 3 6,30 5,25 DN150 (6) 140 780 1.000 56 54 1.127 4.708 3.063 3.463 -

3DK41D 1 4 4 8,30 7,00 DN150 (6) 160 980 1.200 57 55 1.127 5.809 3.107 3.507 -

3DK51D 1 5 5 10,50 8,75 DN150 (6) 180 1.190 1.400 58 56 1.127 6.910 3.151 3.551 3.991

3DK71D 1 7 7 14,70 12,25 DN200 (8) 255 1.630 1.900 60 58 1.127 9.157 3.297 3.697 4.137

3DK101D 1 10 10 21,00 17,50 DN200 (8) 350 2.275 2.700 61 59 1.127 12.460 3.429 3.829 4.269

3DK22D 2 2 4 8,40 7,00 DN150 (6) 235 1.040 1.300 57 55 2.235 3.607 2.925 3.419 -

3DK32D 2 3 6 12,60 10,50 DN150 (6) 275 1.355 1.700 59 57 2.235 4.708 2.925 3.463 -

3DK42D 2 4 8 16,80 14,00 DN150 (6) 315 1.750 2.100 60 58 2.235 5.809 2.925 3.507 -

3DK52D 2 5 10 21,00 17,50 DN150 (6) 360 2.095 2.500 61 59 2.235 6.910 2.925 3.551 3.991

3DK72D 2 7 14 29,40 24,50 DN200 (8) 510 2.855 3.400 62 60 2.235 9.157 2.925 3.697 4.137

3DK102D 2 10 20 42,00 35,00 DN200 (8) 700 3.910 4.700 64 62 2.235 12.460 2.925 3.829 4.269

Power supply voltage and frequency: 380-480±10%/3/50-60Hz


Do NOT use the data in this document for construction purposes. Specifications are subject to change without notice.
Max working temperature: 1,5 bar
(*) Extended support leg requirements (+40 cm or +84 cm) are determined by Frigel.
(**) Add 28 mm for models with EZ fans (21, 22, 31, 32, 41, 42, 51 & 52).
(***) Adiabatic chamber spray connections: 1" GAS-F per row. Unused connections must be plugged. Adiabatic chamber drain connections: 1” hose barb
(****) This is also the approximate rigging weight, excluding the additional weight of the optional extended support legs.
(*****) Operating weights do not include external flooded piping or support steel structures.

Application diagram
Ecodry D version
with pumping station in
serial communication

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Self-Draining with Parallel Coil Configuration (DP)
Water system (no glycol) with recirculation pump stations for moderate climates with minimal
freezing conditions
Sound level
Power input Approximate weights Dimensions (mm) (*)
Fans VictaulicTM Internal dB(A) @10 m
Total
Model Rows per EC fans EZ fans Connections volume
fans Shipping Operating EC Ez C C
row per unit per unit mm (in) (**) liter A B C
kg (***) kg (****) fan fan (+40) (+84)
(kW) (kW)
3DK41DP 1 4 4 8,30 7,00 DN150 (6) 160 975 1.200 57 55 1.127 5.809 3.299 - -

3DK51DP 1 5 5 10,50 8,75 DN150 (6) 180 1.180 1.400 58 56 1.127 6.910 3.343 4.183 -

3DK71DP 1 7 7 14,70 12,25 DN200 (8) 255 1.640 1.900 60 58 1.127 9.157 3.481 4.321 -

3DK101DP 1 10 10 21,00 17,50 DN200 (8) 350 2.275 2.700 61 59 1.127 12.460 3.612 4.452 -

3DK42DP 2 4 8 16,80 14,00 DN150 (6) 315 1.750 2.100 60 58 2.235 5.809 3.299 - -

3DK52DP 2 5 10 21,00 17,50 DN150 (6) 360 2.105 2.500 61 59 2.235 6.910 3.343 4.183 5.223

3DK72DP 2 7 14 29,40 24,50 DN200 (8) 510 2.905 3.400 62 60 2.235 9.157 3.481 4.321 5.361

3DK102DP 2 10 20 42,00 35,00 DN200 (8) 700 3.920 4.700 64 62 2.235 12.460 3.612 4.452 5.492

Power supply voltage and frequency: 380-480±10%/3/50-60Hz


Do NOT use the data in this document for construction purposes. Specifications are subject to change without notice.
Max working temperature: 1,5 bar
(*) Extended support leg requirements (+40 cm or +84 cm) are determined by Frigel.
(**) Adiabatic chamber spray connections: 1" GAS-F per row. Unused connections must be plugged. Adiabatic chamber drain connections: 1” hose barb.
(***) This is also the approximate rigging weight, excluding the additional weight of the optional extended support legs.
(****) Operating weights do not include external flooded piping or support steel structures.

Application diagram
Ecodry DP version
with pumping station in
serial communication

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Self-Draining with Series Coil Configuration (DS)
Water system (no glycol) with recirculation pump stations for moderate climates with minimal
freezing conditions
Sound level
Power input Approximate weights Dimensions (mm) (*)
Fans VictaulicTM Internal dB(A) @10 m
Total
Model Rows per EC fans EZ fans Connections volume
fans Shipping Operating EC Ez C C
row per unit per unit mm (in) (**) liter A B C
kg (***) kg (****) fan fan (+40) (+84)
(kW) (kW)
3DK41DS 1 4 4 8,30 7,00 DN150 (6) 160 1.015 1.200 57 55 1.127 5.809 3.299 - -

3DK51DS 1 5 5 10,50 8,75 DN150 (6) 180 1.220 1.400 58 56 1.127 6.910 3.343 4.183 -

3DK71DS 1 7 7 14,70 12,25 DN200 (8) 255 1.680 1.900 60 58 1.127 9.157 3.481 4.321 -

3DK101DS 1 10 10 21,00 17,50 DN200 (8) 350 2.315 2.700 61 59 1.127 12.460 3.612 4.452 -

3DK42DS 2 4 8 16,80 14,00 DN150 (6) 315 1.810 2.100 60 58 2.235 5.809 3.299 - -

3DK52DS 2 5 10 21,00 17,50 DN150 (6) 360 2.165 2.500 61 59 2.235 6.910 3.343 4.183 2.553

3DK72DS 2 7 14 29,40 24,50 DN200 (8) 510 2.965 3.400 62 60 2.235 9.157 3.481 4.321 5.361

3DK102DS 2 10 20 42,00 35,00 DN200 (8) 700 3.985 4.700 64 62 2.235 12.460 3.612 4.452 5.492

Power supply voltage and frequency: 380-480±10%/3/50-60Hz


Do NOT use the data in this document for construction purposes. Specifications are subject to change without notice.
Max working temperature: 1,5 bar
(*) Extended support leg requirements (+40 cm or +84 cm) are determined by Frigel.
(**) Adiabatic chamber spray connections: 1" GAS-F per row. Unused connections must be plugged. Adiabatic chamber drain connections: 1” hose barb
(***) This is also the approximate rigging weight, excluding the additional weight of the optional extended support legs.
(****) Operating weights do not include external flooded piping or support steel structures.

Application diagram
Ecodry DS version
with pumping station in
serial communication

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]
Ecodry - 3DK
Applications
 Plastics  Data center cooling
 Food and beverage  HVAC
 Metal processing and die casting  Machine tooling
 Power generation  Paper printing
 Pharmaceutical  Textiles
 Ceramics  Wineries and distilleries

Order Code

Summit TPC: Vanguard Tame Park, Tamworth, Staffordshire B77 5DY


T: +44(0)1827 213401 | www.totalprocesscooling.co.uk
[email protected]