Fix Displacement Motor

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

RE 91 001/09.

00

RE 91 001/09.00
replaces: 01.97

Fixed Displacement Motor A2FM


open and closed circuits Sizes 5...1000 Series 6 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar

A2FM

Index
Features Ordering Code / Standard Program Technical Data Ordering Code / Standard Program - Size 5 Unit Dimensions, Size 5 Unit Dimensions, Sizes 10,12,16 Unit Dimensions, Sizes 23, 28, 32 Unit Dimensions, Size 45 Preferred types Unit Dimensions, Sizes 56, 63 Unit Dimensions, Sizes 80, 90 Unit Dimensions, Sizes 107, 125 Unit Dimensions, Sizes 160, 180 Unit Dimensions, Size 200 Unit Dimensions, Size 250 Unit Dimensions, Size 355 Unit Dimensions, Size 500 Unit Dimensions, Size 710 Unit Dimensions, Size 1000 Speed sensor Flushing valves Pressure relief valves Motion Control Valve Installation and Commissioning Guidelines 1 2 4...7 8 8 9 10...11 12...13 13 14...15 16 17 18 19 20 21 22 23 24 25 25 26 27 28

Features
Fixed displacement motor A2FM of axial piston, bent axis design, suitable for hydrostatic drives in open and closed circuits Use in mobile and industrial applications Output speed is proportional to input flow and inversely proportional to displacement Drive torque increases with the pressure drop across the unit Careful selection of the displacements offered, permit sizes to be matched to practically every application Favourable power / weight ratio Compact design Optimum efficiency Economical conception One piece pistons with piston rings

A2FM

1/28

RE 91 001/09.00

Ordering Code / Standard Program


(Ordering code size 5 see page 8) Hydraulic fluid Mineral oil (no code) HFB-, HFC-, HFDsizes 10...200 (no code) Hydraulic fluid sizes 250...1000 (only in connection with drive shaft bearings "L") Axial piston unit Bent axis design, fixed displacement Drive shaft bearings Mechanical bearings (no code) Long-Life bearings Mode of operation Motor (Plug-in motor A2FE see RE 91008)
10...200 250...500 710...1000

E-

A2F

Size Displacement Vg (cm3) 5 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000
Sizes 5...200: production Elchingen Plant; Sizes 250...1000: production Horb Plant

Series 6 Index sizes 10...180 size 200 sizes 250...1000 Direction of rotation viewed on shaft end Seals FKM (flour-caoutchouc) Shaft end 10 Splined shaft DIN 5480 Parallel shaft with key, DIN 6885 Mounting flange ISO 4-hole ISO 8-hole
12 16 23 28 32 45 56 63 80

1 3 0

alternating

V
90 107 125 160 180 200 250 355 500 710 1000

A Z B P

10...250

355...1000

B H

= available = not available Brueninghaus Hydromatik 2/28

= preferred program (preferred types see page 13)

A2FM

RE 91 001/09.00

A2F
Hydraulic fluid Axial piston unit Drive shaft bearings Mode of operation Size Series Index Direction of rotation Seals Shaft end Mounting flange

/ 6

Service line connections1) 10 Ports A and B 01 0 SAE, at rear end 6 Ports A and B 02 0 SAE, opposite side 6 7 Ports A and B 03 0 threads, at side, opposite side 6 Ports A and B 04 0 threads, at side and rear end 6 Ports A and B 10 0 SAE, at side, same side 6 port plate with press. relief valve 18 1 and built-on motion control valve Port plate with integrated 19 1 pressure relief valves 2

12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000


2)

010 016 020 026 027 030 036 040 046 100 106

181 191 192

Valves without valves with pressure relief valves (without pressure sequence range) with pressure relief valves (with pressure sequence range) with integrated flushing valve with built-on flushing and boost valve Speed sensing control without speed sensing control (no code) prepared for speed sensing control Special design without special design (standard type, no code) special design for slew drive applications (standard for port plate 19)
1) Threads 2)

0 1 2 6 7 10...16 23...180 200 250...1000 D

of fixing screws and service lines are metric ports at rear end are plugged 3/28 Brueninghaus Hydromatik

A2FM

RE 91 001/09.00

Technical Data
Fluid To review the application of A2FM motors with the selected hydraulic fluid, detailed fluid compatibility and application data can be found in data sheets RE 90220 (mineral oil), RE 90221 (environmentally acceptable hydraulic fluids) and RE 90223 (fire resistant fluids, HF). The fixed motor A2FM is not suitable for operation with HFA. When using HFB-, HFC-, HFD- or environmentally acceptable hydraulic fluids possible limitations for the technical data have to be taken into consideration. If necessary please consult our technical department (please indicate type of the hydraulic fluid used for your application on the order sheet). Operating viscosity range In order to optain optimum efficiency and service life, we recommend that the operating viscosity (at operating temperature) be selected from within the range opt = opt. operating viscosity 16...36 mm2/s referred to the loop temperature (closed circuit) or tank temperature (open circuit). Viscosity limits The limiting values for viscosity are as follows: Notes on the selection of the hydraulic fluid In order to select the correct fluid, it is necessary to know the operating temperature in the loop (closed circuit) or the tank temperature (open circuit) in relation to the ambient temperature. The hydraulic fluid should be selected so that within the operating temperature range, the operating viscosity lies within the optimum range (opt) (see shaded section of the selection diagram). We recommend that the highest possible viscosity range should be chosen in each case. Example: At an ambient temperature of XC the operating temperature (closed circuit: loop temperature; open circuit: tank temperature) is 60C. Within the operating viscosity range (opt; shaded area), this corresponds to viscosity ranges VG 46 or VG 68. VG 68 should be selected. Important: The leakage oil (case drain oil) temperature is influenced by pressure and motor speed and is always higher than the circuit or tank temperature. However, at no point in the circuit may the temperature exceed 115C for sizes 5...200 or 90C for sizes 250...1000. If it is not possible to comply with the above conditions because of extreme operating parameters or high ambient temperatures please consult us. Filtration The finer the filtration the better the achieved purity grade of the pressure fluid and the longer the life of the axial piston unit. To ensure the functioning of the axial piston unit a minimum purity grade of 9 to NAS 1638 18/15 to ISO/DIS 4406 is necessary. At very high temperatures of the hydraulic fluid (90C to max. 115C,not permissible for sizes 250...1000) at least cleanless class 8 to NAS 1638 17/14 to ISO/DIS 4406 is necessary. If above mentioned grades cannot be maintained please consult us.
60 80 100 1600

sizes 5...200 min = 5 mm2/s, short term at a max. permissible temperature of tmax = 115C max = 1600 mm2/s, short term on cold start (tmin = -40C) sizes 250...1000 min = 10 mm2/s, short term at a max. permissible leakage oil temp. of tmax = 90C max = 1000 mm2/s, short term on cold start (tmin = -25C)

Please note that the max. fluid temperature is also not exceeded in certain areas (for instance bearing area). At temperatures of -25C up to -40C special measures may be required for certain installation positions. Please contact us for further information. Selection diagram 2500-40 -20 0 20 40 1600 1000 600 400
0 10 G V 68 G V 46 G V 32
VG

200

22

viscosity in mm2/s

100 60 40 20 10

36 opt. 16

5 -40

-25

-10 0 10

30

50

70

5 90 115 temperature t in C tmax = +115C

tmin = -40C

fluid temperature range 4/28

Brueninghaus Hydromatik

A2FM

RE 91 001/09.00

Technical Data
Working pressure range maximum pressure at port A or B (Pressure data to DIN 24312) Case drain pressure Shaft seal ring FKM (fluor-caoutchouc) The lower the speed and the case drain pressure the higher the life expectation of the shaft seal ring. The values shown in the diagram are permissible loads of the seal ring and shall not be exceeded. At stationary pressure loads in the range of the max. admissible leakage pressure a reduction of the life experience of the seal ring will result. For a short period (t < 5 min.) are for the sizes 10200 pressure loads up to 5 bar independent from rotational speeds are permissible. Sizes 10...200
10 9

Size 5
Nominal pressure pN Peak pressure pmax

Shaft end B 210 bar 250 bar Shaft end A, Z 2) 400 bar 450 bar

Shaft end C 315 bar 350 bar Shaft end B, P 350 bar 400 bar

Size 10...200 1)
Nominal pressure pN Peak pressure pmax
1) Attention: shaft

perm. pressure pabs. max. (bar)

end Z and P with drives of radial force loads at the drive shaft necessitate reduction of the nominal pressure to pN = 315 bar. 2) Shaft end Z to size 56: p = 350 bar, p N max = 400 bar

8 7 6 5

Sizes 10, 12, 16 Sizes 23, 28, 32 Sizes 45 Sizes 80, 90 Sizes 56, 63

Sizes 250...1000
Nominal pressure pN Peak pressure pmax 350 bar 400 bar

4 3

Sizes 107, 125 Sizes 160, 180 Size 200


0 1000 2000 3000 4000 5000 6000 7000 8000

2 1

With pulsating loads above 315 bar we recommend using the model with splined shaft, standard version A (sizes 10...200) or with splined shaft Z (sizes 250...1000). The summ of the pressures at ports A und B may not exceed 700 bar (630 bar, A2F 5). Direction of flow Clockwise rotation A to B Anti-clockwise rotation B to A

speed n (min-1)

Sizes 250...1000
6
Size 250

perm. pressure pabs. max. (bar)

5
Sizes 710, 1000 Size 355

4 3 2 1 0 500 1000 1500 2000 2500


Size 500

Speed range There is no limitation on minimum speed nmin. If uniformity of rotation is required, however, speed nmin should not be allowed to fall below 50 rpm. See table on page 6 for max. permissible speeds. Long-Life bearings (L) (sizes 250...1000) (for high life expectancy and use of HF-fluids) The outer dimensions of the axial piston motors are identical to standard design (without long life bearings). The change from standard design to long life bearing system is possible. We recommend to apply bearing flushing at port U. Bearing flushing For sizes 2501000 bearing and housing flushing is possible through port U. Flows (recommendation) Sizes qflush (L/min) 250 10 355 16 500 20 710 25 1000 25

speed n (min-1) Note: - max. permissible motor speeds are given in the table on page 6 - max. perm. housing pressure pabs. max ____ 10 bar (sizes 5...200) _____ 6 bar (sizes 250...1000) - the pressure in the housing must be the same as or greater than the external pressure on the shaft seal. Symbol Connections A, B Service line ports T Drain port
A

A2FM

5/28

Brueninghaus Hydromatik

RE 91 001/09.00

Technical Data
Table of values (theoretical values, without considering mh and v; values rounded)

Size
Displacement Max. Speed

5
Vg nmax
nmax p = 350 bar p = 400 bar cm3 min-1 4,93

10
10,3

12
12

16
16

23
22,9

28
28,1

32
32

45
45,6

56
56,1

63
63

80
80,4

10 000 8000 8000 8000 6300 6300 6300 5600 5000 5000 4500

nmax intermit.1) min-1 11 000 8800 8800 8800 6900 6900 6900 6200 5500 5500 5000
Max. flow Torque constants Torque at

qV max TK T T

L/min 49

82

96

128 0,25 88 100 0,17

144 0,36 126 144 0,20

176

201

255

280

315 1,0 350 400 0,45

360 1,27 445 508 0,55

Nm/bar 0,076 0,164 0,19 Nm Nm L 24,7 2) 57 65 0,17 67 76 0,17

0,445 0,509 0,725 0,89 156 178 0,20 178 204 0,20 254 290 0,33 312 356 0,45

Case volume Moment of inertia about drive axis Weight (approx.)

J m

kgm2 0,00008 0,0004 0,0004 0,0004 0,0012 0,0012 0,0012 0,0024 0,0042 0,0042 0,0072 kg 2,5 5,4 5,4 5,4 9,5 9,5 9,5 13,5 18 18 23

Size
Displacement Max. Speed

90
Vg nmax
nmax cm3 90

107

125

160

180

200
200

250
250

355
355

500
500

710
710

1000
1000

106,7 125

160,4 180

min-1 4500 4000 4000 3600 3600 2750 2500 2240 2000 1600 1600 795 7,96

nmax intermit.1) min-1 5000 4400 4400 4000 4000 3000


Max. flow

qV max
Nm/bar

L/min 405 1,43 Nm Nm L 1,70 501 572 0,55

427 1,99 595 680 0,8

500 2,54 697 796 0,8

577 2,86 889

648 3,18

550 3,98

625 5,65

1000 1136 1600 11,3 15,9

Torque constantsTK Torque at

p = 350 bar T p = 400 bar T

1001 1114 1393 1978 2785 3955 5570 3,5 0,178 0,55 155 322 7,8 0,55 336

1016 1144 1272 1,1 1,1 2,5

Case volume Moment of inertia about drive axis Weight (approx.)


1) 2)

J m

kgm2 0,0072 0,0116 0,0116 0,0220 0,0220 0,0378 0,061 0,102 kg 23 32 32 45 45 66 73 110

Intermittent max. speed: overspeed at discharge and overtaking travel operations, t < 5 sek. and p < 150 bar p = 315 bar

Calculation of size Flow

qV =

Vg n 1000 v qV 1000 v Vg Vg p mh 20

in L/min

Output speed

in min-1

Outout torque or Output power

T T P

= TK p mh = 2 T n 60 000 qV p 600 Tn = 9549

in Nm

Vg = geometric displacement per rev. T = torque p = pressure differential n = speed TK = torque constants v = volumetric efficiency mh = mech.-hyd. efficiency t = overall efficiency

in cm3 in Nm in bar in min-1 in Nm/bar

in kW

Brueninghaus Hydromatik

6/28

A2FM

RE 91 001/09.00

Technical Data
Output drive Permissible axial and radial loads on drive shaft The values given are maximum values and do not apply to continuous operation

Size
a Fq max Fax max

5
mm N N
12 710 180 1,5

10
16 2350 320 3,0

12
16 2750 320 3,0

16
16 3700 320 3,0

23
16 4300 500 5,2

28
16 5400 500 5,2

32
16 6100 500 5,2

45
18 8150 630 7,0

56
18 9200 800 8,7

63
18

80
20

10300 11500 800 8,7 1000 10,6

Fax perm./bar N/bar

Size
a Fq max Fax max

90
mm N N +Fax max
- Fax max 20 12900 1000 1000 10,6

107
20

125
20

160
25

180
25

200
25

250
41 12001) 4000 1200
2)

355
52,5 15001) 5000 1500
2)

500
52,5 19001) 6250 1900
2)

710
67,5 30001)

1000
67,5 26001)

13600 15900 18400 1250 1250 12,9 1250 1250 12,9 1600 1600 16,7

20600 22900 1600 1600 16,7 1600 1600 16,7

10000 10000 3000


2)

2600
2)

Fax perm./bar N/bar


1) 2)

Axial piston unit stationary or in bypass operation, please contact us when appearing higher forces! Please contact us!

Code explanation a = distance of Fq from shaft shoulder Fq max = max. perm. radial force at distance a (at intermittent operation) Fax max = max. perm. axial force when stationary or when axial piston unit is running at zero pressure Fax perm./bar = perm. axial force/bar operating pressure

The direction of the max. perm. axial force must be noted by sizes 28...200: = increases bearing life - Fax + Fax = reduces bearing life (avoid if possible)

Optimal force direction of Fq (valid for sizes 10...180) By means of appropriate force directions of Fq the bearing load caused by inside rotary group forces can be reduced. An optimal life expectation of the bearing can be reached.
alternating Motor bei wechselnder rotation Drehrichtung
t op

Minimum inlet pressure at port A (B) In order to avoid damage of the variable motor a minimum inlet pressure at the inlet zone must be assured. The minimum inlet pressure is related to the rotational speed of the fixed motor.
12 10 8 6 4 2 1 0 0,2 0,4 0,6 0,8 1,0

=7

pt

7
0

A
Motor Linkslauf anti-clockwise rotation Druck am pressure at port B Anschlu B

B
Motor Rechtslauf clockwide rotation Druck am pressure A Anschluat port A

B
Motor Linkslauf anti-clockwise rotation Druck am pressure at port B Anschlu B

min. inlet pressure pabs. min (bar)

opt

= 45

op

=4 5

speed n/nmax

A2FM

7/28

Brueninghaus Hydromatik

RE 91 001/09.00

Ordering Code / Standard Program - Size 5

A2F 5 W 6.0
Axial piston unit Bent axis design, fixed displacement Size Displacement Vg (cm3) Direction of rotation viewed on shaft end Series 6.0 Shaft end Parallel shaft with key DIN 6885 Tapered shaft with spigot and spring washer DIN 6888 Service line connections Threads at side, metric A2F

Additional instructions in text form 5 Seals The fixed motor A2F5 is equipped with NBR- (Nitril-caoutchouc) Seals in standard design. In case of need FKM- (fluor-caoutchouc) seals please indicate when ordering in clear text: "with FKM-seals"

alternating

B C = preferred program (preferred types see page 13) 3

Unit Dimensions, Size 5


Before finalising your design, please request a certified drawing.

8
17, 58,

Y
70
5 74, 5 5

Detail Y
R6

T
75

60 h8

25

48,5

6,4

0,1

70

4 51

80

T B

Shaft ends B Parallel shaft with key, DIN 6885 A4x4x20 pN = 210 bar C Tapered shaft with spigot and spring washer 3x5 DIN 6888, pN = 315 bar

Connections B, (A) Service line ports T Drain port

M 18x1,5 M 10x1, both sides

taper 1:10

Brueninghaus Hydromatik

8/28

62

A2FM

RE 91 001/09.00

Unit Dimensions, Sizes 10,12,16


Before finalising your design, please request a certified drawing.

64,5 20 12 6

45

45

T1 5
40
,5 41

95
se ep ort

R 10
pla

80 h6

53,5

10

18,2
8 5

T2

Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged) Port plates 03 Threaded ports, at side 04 Threaded ports, at side and rear end

95

tes

M 12x1,5

10

10

8
55,5 69,5 91

B1 B
34 85

A1 A

55,5

91

130,5 166

85

130,5 147 166

A, B

Service line ports

M 22x1,5

A, B, A1, B1

Service line ports

M 22x1,5

Shaft ends Sizes 10, 12, 16 Sizes 10, 12 Sizes 10, 12, 16 Sizes 10, 12

A Splined shaft, DIN 5480


W 25x1,25x30x18x9g pN = 400 bar

Z Splined shaft, DIN 5480


W 20x1,25x30x14x9g pN = 400 bar

B Parallel shaft with key,


DIN 6885, AS 8x7x32 pN = 350 bar

P Parallel shaft with key,


DIN 6885, AS 6x6x32 pN = 350 bar

A2FM

9/28

Brueninghaus Hydromatik

RE 91 001/09.00

Unit Dimensions, Sizes 23, 28, 32


Before finalising your design, please request a certified drawing.

60,7 25 18 8

45

45

T1
19

se

118

ep

ort

pla

R 12

tes
12 5
11 118

h6

40

100

55,5

19

23,2

48

,5

T2

06

Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged) Port plates 01 SAE-ports, at rear end
12

M 16x1,5

02
115 40,5 40,5
18,2

SAE-ports, at side

13

7 18 ,2

B
78 106

40 13 ,5

70

B
13 59

153 173

M8; 15 deep

M8; 15 deep
144 190

117

120

A, B Service line ports 420 bar (6000 psi) high pressure series

SAE 1/2"

A, B Service line ports 420 bar (6000 psi) high pressure series

SAE 1/2"

03

Threaded ports, at side

04

Threaded ports, at side and rear end


13

13

B1
70 88 117

A1

70

B
117

A
144 166 190

144 190

120

58

120

A, B Service line ports

M 27x2

A, B, A1, B1 Service line ports

M 27x2

Brueninghaus Hydromatik

10/28

A2FM

RE 91 001/09.00

Unit Dimensions, Sizes 23, 28, 32


Before finalising your design, please request a certified drawing.

Port plates 10 SAE-ports, at side, same side

14 9

Detail Y
40

13

106

B
59

91

40,5

158 178

A
M8; 15 deep
Y
18,2

A, B Service line ports 420 bar (6000 psi) high pressure series

SAE 1/2"

Shaft ends

Sizes 23, 28, 32

Sizes 23, 28

40,5

115

Sizes 23, 28, 32

Sizes 23, 28

A Splined shaft, DIN 5480


W 30x2x30x14x9g pN = 400 bar

Z Splined shaft, DIN 5480


W 25x1,25x30x18x9g pN = 400 bar

B Parallel shaft with key,


DIN 6885, AS 8x7x40 pN = 350 bar

P Parallel shaft with key,


DIN 6885, AS 8x7x40 pN = 350 bar

A2FM

11/28

Brueninghaus Hydromatik

RE 91 001/09.00

Unit Dimensions, Size 45


Before finalising your design, please request a certified drawing.

60,3 32 20 12

45

45
150

T1
se
18

ep

ort

R 16

pla

tes
16

125 h6

40

63

18

30

18

T2

Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged) Port plates 01 SAE-ports, at rear end 02
147

13,5

150

52

M 18x1,5

SAE-ports, at side
15

13

50,8

50,8

5 23

B
89 122

A
50 , 19 8

,8

23,8

80

B
133
128

166 194

19 75

M10;17 deep

M10; 17 deep
155 207

A, B Service line ports 420 bar (6000 psi) high pressure series

SAE 3/4"

A, B Service line ports 420 bar (6000 psi) high pressure series

SAE 3/4"

04

Threaded ports, at side and rear end

10

SAE-ports, at side, same side


Detail Y

15 5

16

B1
80 100 133

49

A1
147 75

B
58 128

A
169 193

102

119

B A

155 179 207

23,8

M10; 17deep
Y

A, B, A1, B1 Service line ports

M 33x2

A, B Service line ports 420 bar (6000 psi) high pressure series

SAE 3/4"

Brueninghaus Hydromatik

12/28

A2FM

50,8

50,8

19

RE 91 001/09.00

Unit Dimensions, Size 45


Before finalising your design, please request a certified drawing.

Shaft ends

A Splined shaft, DIN 5480


W 32x2x30x14x9g pN = 400 bar

Z Splined shaft, DIN 5480


W 30x2x30x14x9g pN = 400 bar

P Parallel shaft with key,


DIN 6885, AS 8x7x50 pN = 350 bar

Preferred types
Type A2F5W6.0B3 A2FM10/61W-VAB030 A2FM10/61W-VBB030 A2FM12/61W-VAB030 A2FM12/61W-VBB030 A2FM16/61W-VAB030 A2FM16/61W-VBB030 A2FM23/61W-VAB010 A2FM23/61W-VAB020 A2FM23/61W-VAB040 A2FM23/61W-VBB010 A2FM23/61W-VBB020 A2FM23/61W-VBB040 A2FM28/61W-VAB010 A2FM28/61W-VAB020 A2FM28/61W-VAB040 A2FM28/61W-VBB010 A2FM28/61W-VBB020 A2FM28/61W-VBB040 A2FM32/61W-VAB010 A2FM32/61W-VAB020 A2FM32/61W-VAB040 A2FM32/61W-VBB010 A2FM32/61W-VBB020 A2FM32/61W-VBB040 A2FM45/61W-VZB010 A2FM45/61W-VZB020 A2FM45/61W-VZB040 A2FM56/61W-VAB010 A2FM56/61W-VAB020 A2FM56/61W-VAB040 A2FM56/61W-VBB010 A2FM56/61W-VBB020 A2FM56/61W-VBB040 A2FM63/61W-VAB010 A2FM63/61W-VAB020 A2FM63/61W-VAB040 A2FM63/61W-VBB010 A2FM63/61W-VBB020 A2FM63/61W-VBB040

(please state type and ident-no. when ordering) Ident-No. 9404451 9423386 9610656 9424240 9610657 9411111 9411119 9427351 9422092 9428415 9610658 9610659 9610660 9424853 9422548 9421629 9610661 9610662 9610663 9410189 9410190 9410192 9410194 9410195 9410197 9411581 9411582 9411584 9424905 9422129 9429251 9610664 9610665 9605544 9408523 9408524 9408526 9408514 9408549 9408551 Type A2FM80/61W-VAB010 A2FM80/61W-VAB020 A2FM80/61W-VBB010 A2FM80/61W-VBB020 A2FM90/61W-VAB010 A2FM90/61W-VAB020 A2FM90/61W-VBB010 A2FM90/61W-VBB020 A2FM107/61W-VAB010 A2FM107/61W-VAB020 A2FM107/61W-VBB010 A2FM107/61W-VBB020 A2FM125/61W-VAB010 A2FM125/61W-VAB020 A2FM125/61W-VBB010 A2FM125/61W-VBB020 A2FM160/61W-VAB010 A2FM160/61W-VAB020 A2FM160/61W-VBB010 A2FM160/61W-VBB020 A2FM180/61W-VAB010 A2FM180/61W-VAB020 A2FM180/61W-VBB010 A2FM180/61W-VBB020 A2FM200/63W-VAB010 A2FM250/60W-VZB010 A2FM250/60W-VZB020 A2FM355/60W-VZH010 A2FM500/60W-VPH010 A2FM500/60W-VZH010 A2FLM710/60W-VPH010 A2FLM710/60W-VZH010 A2FM1000/60W-VPH010 A2FM1000/60W-VZH010 Ident-No. 9422638 9422089 9610666 9610667 9408463 9408464 9408468 9408469 9424300 9424093 9610668 9610669 9409630 9409634 9409637 9409638 9425163 9424094 9610670 9610671 9409189 9409190 9409372 9409373 2011528 915383 910653 920780 943251 968982 969815 965974 949444 944773

A2FM

13/28

Brueninghaus Hydromatik

RE 91 001/09.00

Unit Dimensions, Sizes 56, 63


Before finalising your design, please request a certified drawing.

67,5 32 20 10

45

45

T1
se
18

150

ep

ort

R 16

pla

125 h6

tes
16

40

70

18

30

T2

1 28

Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged) Port plates 01 SAE-ports, at rear end
14

13,5

150

56

M 18x1,5

02
147

SAE-ports, at side
16 6,

9,

50,8

50,8

5
23 ,8

B
96 130

A
50 19 ,8

23,8

87

182 206

19

M10; 17 deep
75

M10; 17 deep
171 225
136

A, B Service line ports 420 bar (6000 psi) high pressure series

SAE 3/4"

142

A, B Service line ports 420 bar (6000 psi) high pressure series

SAE 3/4"

04

Threaded ports, at side and rear end

10

SAE-ports, at side, same side


Detail Y

16

6,

17

B1
87 107 142

A1
107

49
50,8 50,8

B A

171 195 225

182

58 136

130

147 75

19

206

23,8

M10; 17 deep
Y

A, B, A1, B1

Service line ports

M 33x2

A, B Service line ports 420 bar (6000 psi) high pressure series

SAE 3/4"

Brueninghaus Hydromatik

14/28

A2FM

RE 91 001/09.00

Unit Dimensions, Sizes 56, 63


Before finalising your design, please request a certified drawing.

Shaft ends

Sizes 56, 63

Size 56

Sizes 56, 63

Size 56

A Splined shaft, DIN 5480


W 35x2x30x16x9g pN = 400 bar

Z Splined shaft, DIN 5480


W 30x2x30x14x9g pN = 350 bar

B Parallel shaft with key,


DIN 6885, AS 10x8x50 pN = 350 bar

P Parallel shaft with key,


DIN 6885, AS 8x7x50 pN = 350 bar

A2FM

15/28

Brueninghaus Hydromatik

RE 91 001/09.00

Unit Dimensions, Sizes 80, 90


Before finalising your design, please request a certified drawing.

78,5 32 20 10

45

45

T1
15

165

se

ep

ort

R 16

pla

140 h6

40

tes
18

83

15

29

38

T2

Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged)

13,5

165

61

M 18x1,5

Port plates 01 SAE-ports, at rear end


16

02
166

SAE-ports, at side
18 9, 5

10

SAE-ports, at side, same side


19 8

2,

Detail Y
60

57,2

57,2

104,5

27,8

25

99

B A

145

145

121

166

84

203

25
233

84

M12; 17 deep

162

196 257

160

M12; 17 deep

206 236

27,8

M12; 17 deep
Y

A, B Service line ports SAE 1" 420 bar (6000 psi) high pressure series

A, B Service line ports SAE 1" 420 bar (6000 psi) high pressure series

A, B Service line ports SAE 1" 420 bar (6000 psi) high pressure series

Shaft ends Sizes 80, 90 Size 80 Sizes 80, 90 Size 80

A Splined shaft, DIN 5480


W 40x2x30x18x9g pN = 400 bar

Z Splined shaft, DIN 5480


W 35x2x30x16x9g pN = 400 bar

B Parallel shaft with key,


DIN 6885, AS 12x8x56 pN = 350 bar

P Parallel shaft with key,


DIN 6885, AS 10x8x56 pN = 350 bar

Brueninghaus Hydromatik

16/28

A2FM

57,2

57,2

A
57 ,2

25

27 ,8

RE 91 001/09.00

Unit Dimensions, Sizes 107, 125


Before finalising your design, please request a certified drawing.

82,8 40 23 10

45

45

T1
se
18

190

ep

ort

R 20

pla

tes
20

160 h6

40

67

85

18

36,5

T2

50

Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged)

17,5

190

M 18x1,5

Port plates 01 SAE-ports, at rear end


18 6,

02
194

SAE-ports, at side
(Klammermae fr NG 107!)
2 31 22 ,8 (2 7, 8

10

SAE-ports, at side, same side


22

Detail Y
4

66,7

66,7
66 ,7 32 (57 (2 ,2) 5)

70
)
110

31,8

B
120 159

A
136 157

B
194 99 66,7
32

181

225,5 252

32
99

M14; 19 deep

178
213 285

226 261

M14; 19 deep (M12; 17 deep)

M14; 19 deep

A
31,8

A, B Service line ports SAE 1 1/ 4" 420 bar (6000 psi) high pressure series

A, B Service line ports SAE 11/4"(1") 420 bar (6000 psi) high pressure series

A, B Service line ports SAE 11/4" 420 bar (6000 psi) high pressure series

Shaft ends Sizes 107, 125 Size 107 Sizes 107, 125 Size 107

A Splined shaft, DIN 5480


W 45x2x30x21x9g pN = 400 bar

Z Splined shaft, DIN 5480


W 40x2x30x18x9g pN = 400 bar

B Parallel shaft with key,


DIN 6885, AS 14x9x63 pN = 350 bar

P Parallel shaft with key,


DIN 6885, AS 12x8x63 pN = 350 bar

A2FM

17/28

Brueninghaus Hydromatik

66.7

RE 91 001/09.00

Unit Dimensions, Sizes 160, 180


Before finalising your design, please request a certified drawing.

93 40 25 10

45

45

T1
19

210

se
,5

ep

ort

R 20

pla

180 h6

40

77

95,5

19,5

22

37,2

T2

1 8

Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged)

17,5

210

tes

,5

M 22x1,5

Port plates 01 SAE-ports, at rear end


20

02
194

SAE-ports, at side
23 31 ,8

10

SAE-ports, at side, same side


24

Detail Y
4

66,7

66,7
31,8

B
134 188

B
121

70

A
149 185

B
66,7
32

66 32

,7

194 99

252 294

32
99

M14; 19 deep

237 294

202

252 290

M14; 19 deep

M14; 19 deep

31,8

A, B Service line ports SAE 1 1 / 4" 420 bar (6000 psi) high pressure series

A, B Service line ports SAE 11/4" 420 bar (6000 psi) high pressure series

Y A, B Service line ports SAE 11/4" 420 bar (6000 psi) high pressure series

Shaft ends Sizes 160, 180 Size160 Sizes 160, 180 Size 160

A Splined shaft, DIN 5480


W 50x2x30x24x9g pN = 400 bar

Z Splined shaft, DIN 5480


W 45x2x30x21x9g pN = 400 bar

B Parallel shaft with key,


DIN 6885, AS 14x9x70 pN = 350 bar

P Parallel shaft with key,


DIN 6885, AS 14x9x70 pN = 350 bar

Brueninghaus Hydromatik

18/28

A2FM

66,7

188

RE 91 001/09.00

Unit Dimensions, Size 200


Before finalising your design, please request a certified drawing.

45
40 9

45

104
32

T
15

see

por

236
t pl

200 -0,029

25

92

22

ates

102,5

15
211

25

32

Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged)

236

M 22x1,5

Port plates 01 SAE-ports, at rear end


199
204 66,7 66,7

B
84

A
31,8

165

284 309

32 99

M14; 19 deep

A, B Service line ports 420 bar (6000 psi) high pressure series

SAE 11/4"

Shaft ends

A Splined shaft, DIN 5480


W 50x2x30x24x9g pN = 400 bar

B Parallel shaft with key, DIN 6885, AS 14x9x80 pN = 350 bar

A2FM

19/28

Brueninghaus Hydromatik

RE 91 001/09.00

Unit Dimensions, Size 250


Before finalising your design, please request a certified drawing.

50 9

82
22

246
45

T
105

45

224 h8

105

263

0 28

172

25 82

22

Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged) U Port for bearing flushing (plugged)

246

124

M 22x1,5 M 14x1,5

Port plates 01 SAE-ports, at rear end


288 66,7 66,7

02

SAE-ports, at side
267 236

31,8

M14; 19 deep
210

93

32 66, 7

32 314 50 50

32

M14; 19 deep

323

A, B Service line ports high pressure series

SAE 11/4"

172

82

A, B Service line ports high pressure series

SAE 11/4"

04

Threaded ports, at side and rear end


267 236

Shaft ends

Z Splined shaft, DIN 5480


B1 B
82

P Parallel shaft with key,


DIN 6885, AS 14x9x80 pN = 350 bar

A1 A
210

W 50x2x30x24x9g pN = 350 bar

172

22 325

85

A, B A1, B1

Service line ports Service line ports (plugged)

M 48x2 M 48x2

Brueninghaus Hydromatik

20/28

A2FM

210

RE 91 001/09.00

Unit Dimensions, Size 355


Before finalising your design, please request a certified drawing.

Port plate 01
50 14 83 23,5

320

2230

45

335

T
128
36 0

280 h8

26 3

102

18

128

198

28 83

T
350

36,6

36,6

Detail X

B
Port plate 10 Detail X
M14; 22 deep

A
79,4 245

MB B
66,7

MB
40
60

MA
40 60
250

241 120

148

199

M16; 21 deep

32

323 370,5

MA
X

31,8

Connections A, B Service line ports T U MA, MB

port plate 01 port plate 10 Drain ports ( 1 port plugged) Port for bearing flushing (plugged) Test ports operating pressure (plugged)

Shaft ends Z Splined shaft, DIN 5480 W 60x2x30x28x9g pN = 350 bar P Parallel shaft with key, DIN 6885, AS 18x11x100 pN = 350 bar

A2FM

21/28

Brueninghaus Hydromatik

335

32

SAE 11/2" SAE 11/4" M 33x2 M 14x1,5 M 14x1,5

170

RE 91 001/09.00

Unit Dimensions, Size 500


Before finalising your design, please request a certified drawing.

361,5 50 14 98 27,5

2230

45

375

T
142
40

315 h8

22

112,5

26 3

142

36

220

30 111

T
396

Detail X

276 36,6 36,6

A MA
79,4 270
M16; 21 deep

Connections A, B Service line ports high pressure series T Drain ports (1 port plugged) U Port for bearing flushing (plugged) MA, MB Test ports operating pressure (plugged)

MB
SAE 11/2" M 33x2 M 18x1,5 M 14x1,5
40 65 65 40

Shaft ends Z Splined shaft, DIN 5480 W 70x3x30x22x9g pN = 350 bar P Parallel shaft with key, DIN 6885, AS 20x12x100 pN = 350 bar

Brueninghaus Hydromatik

22/28

375

A2FM

192

RE 91 001/09.00

Unit Dimensions, Size 710


Before finalising your design, please request a certified drawing.

486 50 14 131 41,5

2230

T
236
0

45

465

183

50

400 h8

1830

102

45

183

252

35 156

T
507
Detail X

344

44,5

44,5

A
MA
96,8 340
M20; 30 deep

Connections A, B Service line ports High pressure series T Drain port (plugged) U Port for bearing flushing (plugged) MA, MB Test ports operating pressure (plugged)

MB
SAE 2" M 42x2 M 18x1,5 M 14x1,5

50 85 85

50

Shaft ends Z Splined shaft, DIN 5480 W 90x3x30x28x9g pN = 350 bar P Parallel shaft with key, DIN 6885, AS 25x14x125 pN = 350 bar

A2FM

23/28

Brueninghaus Hydromatik

465

22

RE 91 001/09.00

Unit Dimensions, Size 1000


Before finalising your design, please request a certified drawing.

468 50 14 131 41,5

2230

45

465

T
183
50 0

400 h8

22

143

263

183

45

279

35 156

T
512

X
Detail X

344

44,5

44,5

MA
Connections A, B Service line ports high pressure series T Drain ports (1 port plugged) U Port for bearing flushing (plugged) MA, MB Test ports operating pressure (plugged) SAE 2" M 42x2 M 18x1,5 M 14x1,5

MB

M20; 30 deep

50 85 85

50

Shaft ends Z Splined shaft, DIN 5480 W 90x3x30x28x9g pN = 350 bar P Parallel shaft with key, DIN 6885, AS 25x14x125 pN = 350 bar

Brueninghaus Hydromatik

24/28

96,8

340

465

236

A2FM

RE 91 001/09.00

Flushing valves
Built-on flushing and boost pressure relief valve (7) This valve is built on to the fixed displacement motor. It must then be noted that only a port plate with ports at side is then available (port plate 02). The flushing and boost pressure relief valve has a fixed setting of 16 bar (the setting of the primary boost pressure relief valve must be noted) and is used to safeguard the minimum boost pressure. A fixed flow of fluid is taken via an orifice from the low A (B) T2 pressure side of the circuit and fed into the motor housing. This flow is then passed back to tank with the case drain fluid. Fluid thus removed from the closed circuit must be T1 B (A) made up by means of the boost pump.
A1

Size Flushing flow (at low pressure p = 25 bar) * 45, 56, 63 3,5 L/min Orifice-No.: 651766/503.12.01.01 80, 90 5 L/min Orifice-No.: 419695/503.12.01.01 107, 125 8 L/min Orifice-No.: 419696/503.12.01.01 160, 180 10 L/min Orifice-No.: 419697/503.12.01.01 250 10 L/min * Standard flushing volumes (for sizes 45180 flushing volumes of 3,5 - 10 L/min can be supplied. If a flushing volume different from the standard flushing volume is required, please indicate the requested orifice in clear text when ordering).

Integrated flushing valve (6) (Size 23...90) The valve is integrated into the port plate.

A
T2

A (B)

Y
A2

B
T1 B (A)

- switching pressure p 8 bar (this value is lower than the starting pressure of an unloaded motor). - closed in centre position (p < 8 bar). Flushing flow (at low pressure p = 25 bar) 2,5 L/min 3,1 L/min 4,1 L/min

98

Size 45 A1 223 A2 151

56, 63 239 159

80, 90 268 173,5

107, 125 160, 180 294 315 192 201

250 344 154

Size 23, 32 45, 56, 63 80, 90

Speed sensor
Version A2FMD ("suitable for fitting speed sensor") includes gearing on the rotary group and in addition the port M or D (M18x1,5), in which a speed sensor is screwed in. A speed-proportional signal is produced by means of the rotating, splined rotary group which can be picked up by a suitable sensor and fed back for evaluation. Sizes 23...180
A1

Sizes 23, 28, 32 45 56, 63 80, 90 107, 125 160, 180 250 355 500 710...1000

NO. of teath 38 45 47 53 59 67 78 90 99 126

length of thread 12,7 11,2 14,7 14,7 14,7 14,7 variable variable variable variable

A1 58,7 54,8 61,5 72,5 74,8 91 82 93 110 160

A2 50 54,5 60 65,8 75 83 103 128 140 163

Sizes 250...1000
30

M (M18x1,5)

D (M18x1,5)
A2

A2

The speed sensor is not included in standard supply. Suitable sensors (order seperately!): - Induktive impulse detector ID (see RE 95130) (only for sizes 23...180) - Hall effect speed sensor HD (see RE 95134)

A2FM

25/28

Brueninghaus Hydromatik

RE 91 001/09.00

Pressure relief valves

(for port plate 18 or 19 only)


Before finalising your design, please request a certified drawing.

The pressure relief valves MHDB (as to RE 64642) are protecting the motor against overcharge. As soon as the set opening pressure is reached the oil is flowing from the high pressure side to the low pressure side. Setting range opening pressure _______________ 50 420 bar At design with pressure sequence range (2) a higher pressure setting can be realized by applying an external pilot pressure of 25 30 bar at port pSt. Please indicate in clear when ordering : - opening pressure of the pressure relief valve - opening pressure at pilot pressure applied at pSt (for design 2 only)

D1 D2 D5

Pressure relief valve


with pressure sequence range (2)

T2 MB Y
Detail Y

D7 D6

D3

Z S1
Detail Z D8

pSt MB

T2

B
S1
A
D9

B
D10 D12

A
pSt MA T1
D13

D11

MB
only for port plate 18

Fixed Displacement Motor A2FM, with integrated pressure relief valve (with pressure sequence range) Sizes 28, 32 45 56, 63 80, 90 107, 125 160, 180 Ports A, B SAE 3/4" SAE 3/4" SAE 3/4" SAE 1" S1 M 22x1,5 M 22x1,5 M 26x1,5 M 26x1,5 MA , MB M 20x1,5 M 20x1,5 M 26x1,5 M 26x1,5 M 26x1,5 M 30x1,5 pSt G 1/4 G 1/4 G 1/4 G 1/4 G 1/4 G 1/4

S1 only for port


plate 19

Connections A, B Service line ports S1 Boosting (only for port plate 19) MA, MB Test ports (plugged) pSt Pilot pressure port (only for design 2)

SAE 11/4" M 26x1,5 SAE 11/4" M 26x1,5

Sizes 28, 32 45 56, 63 80, 90 MHDB.16 MHDB.16 MHDB.22 MHDB.22

D1 209 222 250 271 298 332

D2 186 198 222 267 301

D3 25 22 19 10 5

D4 63 60 57 55 48 43

D5 174 187 208 229 251 285

D6 102 113 124 134 170

D7 87 98 105 114 149

D8 36 36 42 42 53 53

D9 66 66 75 75 84 84

D10 50,8 50,8 50,8 57,2 66,7 66,7

D11 23,8 23,8 23,8 27,8 31,8 31,8

D12 19 19 19 25 32 32

D13 M10; 17 deep M10; 17 deep M10; 13 deep M12; 18 deep M14; 19 deep M14; 19 deep

243,5 17,5

107, 125 MHDB.32 160, 180 MHDB.32

149,5 130

Brueninghaus Hydromatik

26/28

A2FM

D4

T1

without pressure sequence rangee (1)

pSt

MA

SAE

RE 91 001/09.00

Motion Control Valve

(for port plate 18 only)


Before finalising your design, please request a certified drawing.

For hydro-motors operating in open loop the motion control valve BVD (as to RE 95522) is avoiding an overspeed and thus a lack of filling. A lack of filling occurs at the hydro-motors as soon as the speed of the drive from external is exceeding the speed corresponding to the added volume flow. The motion control valve is not included in the type code of the A2FM motor and has to be indicated separately when ordering. At shipment it is fixed at the motor with 2 tacking bolts (do not remove the tacking bolts during fixing of the service lines). At separated shipment of motion control valve and motor the motion control valve has to be fixed in a first step with the added tacking bolts to the cover plate of the motor. The final fixing of the motion control valve at the motor is effected in both cases by fitting the service lines ( observe screw-in depth B4 + B12 and B13)!
MB B S Gext A
B7 B6

B1 B3
T

B12
B5

T2

A,B
Detail Y

Y
B13

B
tacking bolts (M6)
B8 B9

MA

T1
B10

A
B11

Fixed displacement motor A2FM, motion control valve BVD and integrated pressure relief valve Sizes 28, 32 45 56, 63 80, 90 ports BVD20..16 BVD20..16 BVD20..17 BVD20..27 A, B SAE 3/4" SAE 3/4" SAE 3/4" SAE 1" SAE 11/4" SAE 11/4" B1 BVD20..16 BVD20..16 BVD20..17 BVD20..27 209 229 250 271 298 332 B2 180 191 192 202 255 S M 22x1,5 M 22x1,5 M 22x1,5 M 22x1,5 M 27x2 M 27x2 B3 174 187 208 229 285 B4
1 1

MA,MB M12x1,5 M12x1,5 M12x1,5 M12x1,5 M12x1,5 M12x1,5 B5 B6

Connections A, B Service line ports SAE S Boosting (plugged) MA,MB Test ports (plugged)

107, 125 BVD25..38 160, 180 BVD25..38 Sizes 28, 32 45 56, 63 80, 90

B7

B8 66 66 75 75

B9

B10 B11

B12

B4

MB

78 ) 137 78 ) 137 68 68 85 85 137 137

235 96 235 96 235 96 235 96

23,8 50,8 19 23,8 50,8 19 23,8 50,8 19 27,8 57,2 25 31,8 66,7 32 31,8 66,7 32

M10; 17 deep M10; 14 deep M10; 17 deep M10; 14 deep M10; 17 deep M10; 14 deep M12; 18 deep M12; 16 deep M14; 19 deep M14; 19 deep M14; 19 deep M14; 19 deep

107, 125 BVD25..38 160, 180 BVD25..38


1

234,5 251

151,5 286 120,5 84 151,5 286 120,5 84

) with adapting plate

A2FM

27/28

Brueninghaus Hydromatik

B2

B13

RE 91 001/09.00

Installation and Commissioning Guidelines


General At start-up and during operation the motor housing has imperatively to be filled up with hydraulic fluid (filling of the case chamber). Startup has to be carried out at low speed and without load till the system is completely bleeded. At a longer standstill the case may discharge via operating line. At new start-up a sufficient filling of the housing has to be granted. The leakage oil in the housing has to be discharged to the tank via highest positioned case drain port. Installation position Optional. At size 10 ... 200 with installation position shaft to the top use motor with bleeding port R (indicate in clear when ordering; the port U in the bearing section for bleeding is included in series at size 250 ... 1000). Installation below tank level Motors below min. oil level in the tank (standard) Fill up axial piston motor before start-up via highest positioned case drain port Note for the shaft on top installation position: the motor case has to be filled up completely at start-up (bleeding at additional port R (size 10 ... 200) resp. U (size 250 ... 1000). An air pocket in the bearing area is leading to damage of the axial piston unit. Operate motor at low speed (igniton speed) till motor system is completely filled up Minimum immersion depth of the suction line or drain line in the tank: 200 mm (relative to the min. oil level in the tank).
T1

Installation on top of tank level Motor on top of min. oil level in the tank Actions as installation below tank level Installation position 1 and 2: If the motor is left at standstill for a long period, the oil in the housing chamber may fully drain out through the operating lines (air entering via the shaft seal). Consequently, on restarting, the bearings will be insufficiently lubricated. You should therefore refill the axial piston unit via the highest positioned drain port before restarting (Installation position 2: air bleed via port R or U). Installation position 2 (shaft on top) In this installation position, the bearings will be insufficiently lubricated even if the housing chamber is only partially drained. To prevent oil draining via the drain port, insert a check valve in the drain line (opening pressure 0.5 bar).

T1 T2

2
0,5 bar

* *
R(U)

T2
T1 T2

*
R(U) T1 T2

Brueninghaus Hydromatik GmbH Elchingen Plant Glockeraustrae 2 D89275 Elchingen Phone +49 (0) 73 08 82-0 Telefax +49 (0) 73 08 72 74 Horb Plant An den Kelterwiesen 14 D72160 Horb Phone +49 (0) 74 51 92-0 Telefax +49 (0) 74 51 82 21 The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract. All rights reserved - Subject to revision

Internet: www.rexroth.com/brueninghaushydromatik / E-Mail: [email protected] Nachdruck verboten nderungen vorbehalten 28/28

A2FM

You might also like