Fix Displacement Motor
Fix Displacement Motor
Fix Displacement Motor
00
RE 91 001/09.00
replaces: 01.97
A2FM
Index
Features Ordering Code / Standard Program Technical Data Ordering Code / Standard Program - Size 5 Unit Dimensions, Size 5 Unit Dimensions, Sizes 10,12,16 Unit Dimensions, Sizes 23, 28, 32 Unit Dimensions, Size 45 Preferred types Unit Dimensions, Sizes 56, 63 Unit Dimensions, Sizes 80, 90 Unit Dimensions, Sizes 107, 125 Unit Dimensions, Sizes 160, 180 Unit Dimensions, Size 200 Unit Dimensions, Size 250 Unit Dimensions, Size 355 Unit Dimensions, Size 500 Unit Dimensions, Size 710 Unit Dimensions, Size 1000 Speed sensor Flushing valves Pressure relief valves Motion Control Valve Installation and Commissioning Guidelines 1 2 4...7 8 8 9 10...11 12...13 13 14...15 16 17 18 19 20 21 22 23 24 25 25 26 27 28
Features
Fixed displacement motor A2FM of axial piston, bent axis design, suitable for hydrostatic drives in open and closed circuits Use in mobile and industrial applications Output speed is proportional to input flow and inversely proportional to displacement Drive torque increases with the pressure drop across the unit Careful selection of the displacements offered, permit sizes to be matched to practically every application Favourable power / weight ratio Compact design Optimum efficiency Economical conception One piece pistons with piston rings
A2FM
1/28
RE 91 001/09.00
E-
A2F
Size Displacement Vg (cm3) 5 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000
Sizes 5...200: production Elchingen Plant; Sizes 250...1000: production Horb Plant
Series 6 Index sizes 10...180 size 200 sizes 250...1000 Direction of rotation viewed on shaft end Seals FKM (flour-caoutchouc) Shaft end 10 Splined shaft DIN 5480 Parallel shaft with key, DIN 6885 Mounting flange ISO 4-hole ISO 8-hole
12 16 23 28 32 45 56 63 80
1 3 0
alternating
V
90 107 125 160 180 200 250 355 500 710 1000
A Z B P
10...250
355...1000
B H
A2FM
RE 91 001/09.00
A2F
Hydraulic fluid Axial piston unit Drive shaft bearings Mode of operation Size Series Index Direction of rotation Seals Shaft end Mounting flange
/ 6
Service line connections1) 10 Ports A and B 01 0 SAE, at rear end 6 Ports A and B 02 0 SAE, opposite side 6 7 Ports A and B 03 0 threads, at side, opposite side 6 Ports A and B 04 0 threads, at side and rear end 6 Ports A and B 10 0 SAE, at side, same side 6 port plate with press. relief valve 18 1 and built-on motion control valve Port plate with integrated 19 1 pressure relief valves 2
12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000
2)
010 016 020 026 027 030 036 040 046 100 106
Valves without valves with pressure relief valves (without pressure sequence range) with pressure relief valves (with pressure sequence range) with integrated flushing valve with built-on flushing and boost valve Speed sensing control without speed sensing control (no code) prepared for speed sensing control Special design without special design (standard type, no code) special design for slew drive applications (standard for port plate 19)
1) Threads 2)
of fixing screws and service lines are metric ports at rear end are plugged 3/28 Brueninghaus Hydromatik
A2FM
RE 91 001/09.00
Technical Data
Fluid To review the application of A2FM motors with the selected hydraulic fluid, detailed fluid compatibility and application data can be found in data sheets RE 90220 (mineral oil), RE 90221 (environmentally acceptable hydraulic fluids) and RE 90223 (fire resistant fluids, HF). The fixed motor A2FM is not suitable for operation with HFA. When using HFB-, HFC-, HFD- or environmentally acceptable hydraulic fluids possible limitations for the technical data have to be taken into consideration. If necessary please consult our technical department (please indicate type of the hydraulic fluid used for your application on the order sheet). Operating viscosity range In order to optain optimum efficiency and service life, we recommend that the operating viscosity (at operating temperature) be selected from within the range opt = opt. operating viscosity 16...36 mm2/s referred to the loop temperature (closed circuit) or tank temperature (open circuit). Viscosity limits The limiting values for viscosity are as follows: Notes on the selection of the hydraulic fluid In order to select the correct fluid, it is necessary to know the operating temperature in the loop (closed circuit) or the tank temperature (open circuit) in relation to the ambient temperature. The hydraulic fluid should be selected so that within the operating temperature range, the operating viscosity lies within the optimum range (opt) (see shaded section of the selection diagram). We recommend that the highest possible viscosity range should be chosen in each case. Example: At an ambient temperature of XC the operating temperature (closed circuit: loop temperature; open circuit: tank temperature) is 60C. Within the operating viscosity range (opt; shaded area), this corresponds to viscosity ranges VG 46 or VG 68. VG 68 should be selected. Important: The leakage oil (case drain oil) temperature is influenced by pressure and motor speed and is always higher than the circuit or tank temperature. However, at no point in the circuit may the temperature exceed 115C for sizes 5...200 or 90C for sizes 250...1000. If it is not possible to comply with the above conditions because of extreme operating parameters or high ambient temperatures please consult us. Filtration The finer the filtration the better the achieved purity grade of the pressure fluid and the longer the life of the axial piston unit. To ensure the functioning of the axial piston unit a minimum purity grade of 9 to NAS 1638 18/15 to ISO/DIS 4406 is necessary. At very high temperatures of the hydraulic fluid (90C to max. 115C,not permissible for sizes 250...1000) at least cleanless class 8 to NAS 1638 17/14 to ISO/DIS 4406 is necessary. If above mentioned grades cannot be maintained please consult us.
60 80 100 1600
sizes 5...200 min = 5 mm2/s, short term at a max. permissible temperature of tmax = 115C max = 1600 mm2/s, short term on cold start (tmin = -40C) sizes 250...1000 min = 10 mm2/s, short term at a max. permissible leakage oil temp. of tmax = 90C max = 1000 mm2/s, short term on cold start (tmin = -25C)
Please note that the max. fluid temperature is also not exceeded in certain areas (for instance bearing area). At temperatures of -25C up to -40C special measures may be required for certain installation positions. Please contact us for further information. Selection diagram 2500-40 -20 0 20 40 1600 1000 600 400
0 10 G V 68 G V 46 G V 32
VG
200
22
viscosity in mm2/s
100 60 40 20 10
36 opt. 16
5 -40
-25
-10 0 10
30
50
70
tmin = -40C
Brueninghaus Hydromatik
A2FM
RE 91 001/09.00
Technical Data
Working pressure range maximum pressure at port A or B (Pressure data to DIN 24312) Case drain pressure Shaft seal ring FKM (fluor-caoutchouc) The lower the speed and the case drain pressure the higher the life expectation of the shaft seal ring. The values shown in the diagram are permissible loads of the seal ring and shall not be exceeded. At stationary pressure loads in the range of the max. admissible leakage pressure a reduction of the life experience of the seal ring will result. For a short period (t < 5 min.) are for the sizes 10200 pressure loads up to 5 bar independent from rotational speeds are permissible. Sizes 10...200
10 9
Size 5
Nominal pressure pN Peak pressure pmax
Shaft end B 210 bar 250 bar Shaft end A, Z 2) 400 bar 450 bar
Shaft end C 315 bar 350 bar Shaft end B, P 350 bar 400 bar
Size 10...200 1)
Nominal pressure pN Peak pressure pmax
1) Attention: shaft
end Z and P with drives of radial force loads at the drive shaft necessitate reduction of the nominal pressure to pN = 315 bar. 2) Shaft end Z to size 56: p = 350 bar, p N max = 400 bar
8 7 6 5
Sizes 10, 12, 16 Sizes 23, 28, 32 Sizes 45 Sizes 80, 90 Sizes 56, 63
Sizes 250...1000
Nominal pressure pN Peak pressure pmax 350 bar 400 bar
4 3
2 1
With pulsating loads above 315 bar we recommend using the model with splined shaft, standard version A (sizes 10...200) or with splined shaft Z (sizes 250...1000). The summ of the pressures at ports A und B may not exceed 700 bar (630 bar, A2F 5). Direction of flow Clockwise rotation A to B Anti-clockwise rotation B to A
speed n (min-1)
Sizes 250...1000
6
Size 250
5
Sizes 710, 1000 Size 355
Speed range There is no limitation on minimum speed nmin. If uniformity of rotation is required, however, speed nmin should not be allowed to fall below 50 rpm. See table on page 6 for max. permissible speeds. Long-Life bearings (L) (sizes 250...1000) (for high life expectancy and use of HF-fluids) The outer dimensions of the axial piston motors are identical to standard design (without long life bearings). The change from standard design to long life bearing system is possible. We recommend to apply bearing flushing at port U. Bearing flushing For sizes 2501000 bearing and housing flushing is possible through port U. Flows (recommendation) Sizes qflush (L/min) 250 10 355 16 500 20 710 25 1000 25
speed n (min-1) Note: - max. permissible motor speeds are given in the table on page 6 - max. perm. housing pressure pabs. max ____ 10 bar (sizes 5...200) _____ 6 bar (sizes 250...1000) - the pressure in the housing must be the same as or greater than the external pressure on the shaft seal. Symbol Connections A, B Service line ports T Drain port
A
A2FM
5/28
Brueninghaus Hydromatik
RE 91 001/09.00
Technical Data
Table of values (theoretical values, without considering mh and v; values rounded)
Size
Displacement Max. Speed
5
Vg nmax
nmax p = 350 bar p = 400 bar cm3 min-1 4,93
10
10,3
12
12
16
16
23
22,9
28
28,1
32
32
45
45,6
56
56,1
63
63
80
80,4
10 000 8000 8000 8000 6300 6300 6300 5600 5000 5000 4500
nmax intermit.1) min-1 11 000 8800 8800 8800 6900 6900 6900 6200 5500 5500 5000
Max. flow Torque constants Torque at
qV max TK T T
L/min 49
82
96
176
201
255
280
0,445 0,509 0,725 0,89 156 178 0,20 178 204 0,20 254 290 0,33 312 356 0,45
J m
kgm2 0,00008 0,0004 0,0004 0,0004 0,0012 0,0012 0,0012 0,0024 0,0042 0,0042 0,0072 kg 2,5 5,4 5,4 5,4 9,5 9,5 9,5 13,5 18 18 23
Size
Displacement Max. Speed
90
Vg nmax
nmax cm3 90
107
125
160
180
200
200
250
250
355
355
500
500
710
710
1000
1000
106,7 125
160,4 180
min-1 4500 4000 4000 3600 3600 2750 2500 2240 2000 1600 1600 795 7,96
qV max
Nm/bar
648 3,18
550 3,98
625 5,65
1001 1114 1393 1978 2785 3955 5570 3,5 0,178 0,55 155 322 7,8 0,55 336
J m
kgm2 0,0072 0,0116 0,0116 0,0220 0,0220 0,0378 0,061 0,102 kg 23 32 32 45 45 66 73 110
Intermittent max. speed: overspeed at discharge and overtaking travel operations, t < 5 sek. and p < 150 bar p = 315 bar
qV =
Vg n 1000 v qV 1000 v Vg Vg p mh 20
in L/min
Output speed
in min-1
T T P
in Nm
Vg = geometric displacement per rev. T = torque p = pressure differential n = speed TK = torque constants v = volumetric efficiency mh = mech.-hyd. efficiency t = overall efficiency
in kW
Brueninghaus Hydromatik
6/28
A2FM
RE 91 001/09.00
Technical Data
Output drive Permissible axial and radial loads on drive shaft The values given are maximum values and do not apply to continuous operation
Size
a Fq max Fax max
5
mm N N
12 710 180 1,5
10
16 2350 320 3,0
12
16 2750 320 3,0
16
16 3700 320 3,0
23
16 4300 500 5,2
28
16 5400 500 5,2
32
16 6100 500 5,2
45
18 8150 630 7,0
56
18 9200 800 8,7
63
18
80
20
Size
a Fq max Fax max
90
mm N N +Fax max
- Fax max 20 12900 1000 1000 10,6
107
20
125
20
160
25
180
25
200
25
250
41 12001) 4000 1200
2)
355
52,5 15001) 5000 1500
2)
500
52,5 19001) 6250 1900
2)
710
67,5 30001)
1000
67,5 26001)
13600 15900 18400 1250 1250 12,9 1250 1250 12,9 1600 1600 16,7
2600
2)
Axial piston unit stationary or in bypass operation, please contact us when appearing higher forces! Please contact us!
Code explanation a = distance of Fq from shaft shoulder Fq max = max. perm. radial force at distance a (at intermittent operation) Fax max = max. perm. axial force when stationary or when axial piston unit is running at zero pressure Fax perm./bar = perm. axial force/bar operating pressure
The direction of the max. perm. axial force must be noted by sizes 28...200: = increases bearing life - Fax + Fax = reduces bearing life (avoid if possible)
Optimal force direction of Fq (valid for sizes 10...180) By means of appropriate force directions of Fq the bearing load caused by inside rotary group forces can be reduced. An optimal life expectation of the bearing can be reached.
alternating Motor bei wechselnder rotation Drehrichtung
t op
Minimum inlet pressure at port A (B) In order to avoid damage of the variable motor a minimum inlet pressure at the inlet zone must be assured. The minimum inlet pressure is related to the rotational speed of the fixed motor.
12 10 8 6 4 2 1 0 0,2 0,4 0,6 0,8 1,0
=7
pt
7
0
A
Motor Linkslauf anti-clockwise rotation Druck am pressure at port B Anschlu B
B
Motor Rechtslauf clockwide rotation Druck am pressure A Anschluat port A
B
Motor Linkslauf anti-clockwise rotation Druck am pressure at port B Anschlu B
opt
= 45
op
=4 5
speed n/nmax
A2FM
7/28
Brueninghaus Hydromatik
RE 91 001/09.00
A2F 5 W 6.0
Axial piston unit Bent axis design, fixed displacement Size Displacement Vg (cm3) Direction of rotation viewed on shaft end Series 6.0 Shaft end Parallel shaft with key DIN 6885 Tapered shaft with spigot and spring washer DIN 6888 Service line connections Threads at side, metric A2F
Additional instructions in text form 5 Seals The fixed motor A2F5 is equipped with NBR- (Nitril-caoutchouc) Seals in standard design. In case of need FKM- (fluor-caoutchouc) seals please indicate when ordering in clear text: "with FKM-seals"
alternating
8
17, 58,
Y
70
5 74, 5 5
Detail Y
R6
T
75
60 h8
25
48,5
6,4
0,1
70
4 51
80
T B
Shaft ends B Parallel shaft with key, DIN 6885 A4x4x20 pN = 210 bar C Tapered shaft with spigot and spring washer 3x5 DIN 6888, pN = 315 bar
taper 1:10
Brueninghaus Hydromatik
8/28
62
A2FM
RE 91 001/09.00
64,5 20 12 6
45
45
T1 5
40
,5 41
95
se ep ort
R 10
pla
80 h6
53,5
10
18,2
8 5
T2
Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged) Port plates 03 Threaded ports, at side 04 Threaded ports, at side and rear end
95
tes
M 12x1,5
10
10
8
55,5 69,5 91
B1 B
34 85
A1 A
55,5
91
130,5 166
85
A, B
M 22x1,5
A, B, A1, B1
M 22x1,5
Shaft ends Sizes 10, 12, 16 Sizes 10, 12 Sizes 10, 12, 16 Sizes 10, 12
A2FM
9/28
Brueninghaus Hydromatik
RE 91 001/09.00
60,7 25 18 8
45
45
T1
19
se
118
ep
ort
pla
R 12
tes
12 5
11 118
h6
40
100
55,5
19
23,2
48
,5
T2
06
Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged) Port plates 01 SAE-ports, at rear end
12
M 16x1,5
02
115 40,5 40,5
18,2
SAE-ports, at side
13
7 18 ,2
B
78 106
40 13 ,5
70
B
13 59
153 173
M8; 15 deep
M8; 15 deep
144 190
117
120
A, B Service line ports 420 bar (6000 psi) high pressure series
SAE 1/2"
A, B Service line ports 420 bar (6000 psi) high pressure series
SAE 1/2"
03
04
13
B1
70 88 117
A1
70
B
117
A
144 166 190
144 190
120
58
120
M 27x2
M 27x2
Brueninghaus Hydromatik
10/28
A2FM
RE 91 001/09.00
14 9
Detail Y
40
13
106
B
59
91
40,5
158 178
A
M8; 15 deep
Y
18,2
A, B Service line ports 420 bar (6000 psi) high pressure series
SAE 1/2"
Shaft ends
Sizes 23, 28
40,5
115
Sizes 23, 28
A2FM
11/28
Brueninghaus Hydromatik
RE 91 001/09.00
60,3 32 20 12
45
45
150
T1
se
18
ep
ort
R 16
pla
tes
16
125 h6
40
63
18
30
18
T2
Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged) Port plates 01 SAE-ports, at rear end 02
147
13,5
150
52
M 18x1,5
SAE-ports, at side
15
13
50,8
50,8
5 23
B
89 122
A
50 , 19 8
,8
23,8
80
B
133
128
166 194
19 75
M10;17 deep
M10; 17 deep
155 207
A, B Service line ports 420 bar (6000 psi) high pressure series
SAE 3/4"
A, B Service line ports 420 bar (6000 psi) high pressure series
SAE 3/4"
04
10
15 5
16
B1
80 100 133
49
A1
147 75
B
58 128
A
169 193
102
119
B A
23,8
M10; 17deep
Y
M 33x2
A, B Service line ports 420 bar (6000 psi) high pressure series
SAE 3/4"
Brueninghaus Hydromatik
12/28
A2FM
50,8
50,8
19
RE 91 001/09.00
Shaft ends
Preferred types
Type A2F5W6.0B3 A2FM10/61W-VAB030 A2FM10/61W-VBB030 A2FM12/61W-VAB030 A2FM12/61W-VBB030 A2FM16/61W-VAB030 A2FM16/61W-VBB030 A2FM23/61W-VAB010 A2FM23/61W-VAB020 A2FM23/61W-VAB040 A2FM23/61W-VBB010 A2FM23/61W-VBB020 A2FM23/61W-VBB040 A2FM28/61W-VAB010 A2FM28/61W-VAB020 A2FM28/61W-VAB040 A2FM28/61W-VBB010 A2FM28/61W-VBB020 A2FM28/61W-VBB040 A2FM32/61W-VAB010 A2FM32/61W-VAB020 A2FM32/61W-VAB040 A2FM32/61W-VBB010 A2FM32/61W-VBB020 A2FM32/61W-VBB040 A2FM45/61W-VZB010 A2FM45/61W-VZB020 A2FM45/61W-VZB040 A2FM56/61W-VAB010 A2FM56/61W-VAB020 A2FM56/61W-VAB040 A2FM56/61W-VBB010 A2FM56/61W-VBB020 A2FM56/61W-VBB040 A2FM63/61W-VAB010 A2FM63/61W-VAB020 A2FM63/61W-VAB040 A2FM63/61W-VBB010 A2FM63/61W-VBB020 A2FM63/61W-VBB040
(please state type and ident-no. when ordering) Ident-No. 9404451 9423386 9610656 9424240 9610657 9411111 9411119 9427351 9422092 9428415 9610658 9610659 9610660 9424853 9422548 9421629 9610661 9610662 9610663 9410189 9410190 9410192 9410194 9410195 9410197 9411581 9411582 9411584 9424905 9422129 9429251 9610664 9610665 9605544 9408523 9408524 9408526 9408514 9408549 9408551 Type A2FM80/61W-VAB010 A2FM80/61W-VAB020 A2FM80/61W-VBB010 A2FM80/61W-VBB020 A2FM90/61W-VAB010 A2FM90/61W-VAB020 A2FM90/61W-VBB010 A2FM90/61W-VBB020 A2FM107/61W-VAB010 A2FM107/61W-VAB020 A2FM107/61W-VBB010 A2FM107/61W-VBB020 A2FM125/61W-VAB010 A2FM125/61W-VAB020 A2FM125/61W-VBB010 A2FM125/61W-VBB020 A2FM160/61W-VAB010 A2FM160/61W-VAB020 A2FM160/61W-VBB010 A2FM160/61W-VBB020 A2FM180/61W-VAB010 A2FM180/61W-VAB020 A2FM180/61W-VBB010 A2FM180/61W-VBB020 A2FM200/63W-VAB010 A2FM250/60W-VZB010 A2FM250/60W-VZB020 A2FM355/60W-VZH010 A2FM500/60W-VPH010 A2FM500/60W-VZH010 A2FLM710/60W-VPH010 A2FLM710/60W-VZH010 A2FM1000/60W-VPH010 A2FM1000/60W-VZH010 Ident-No. 9422638 9422089 9610666 9610667 9408463 9408464 9408468 9408469 9424300 9424093 9610668 9610669 9409630 9409634 9409637 9409638 9425163 9424094 9610670 9610671 9409189 9409190 9409372 9409373 2011528 915383 910653 920780 943251 968982 969815 965974 949444 944773
A2FM
13/28
Brueninghaus Hydromatik
RE 91 001/09.00
67,5 32 20 10
45
45
T1
se
18
150
ep
ort
R 16
pla
125 h6
tes
16
40
70
18
30
T2
1 28
Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged) Port plates 01 SAE-ports, at rear end
14
13,5
150
56
M 18x1,5
02
147
SAE-ports, at side
16 6,
9,
50,8
50,8
5
23 ,8
B
96 130
A
50 19 ,8
23,8
87
182 206
19
M10; 17 deep
75
M10; 17 deep
171 225
136
A, B Service line ports 420 bar (6000 psi) high pressure series
SAE 3/4"
142
A, B Service line ports 420 bar (6000 psi) high pressure series
SAE 3/4"
04
10
16
6,
17
B1
87 107 142
A1
107
49
50,8 50,8
B A
182
58 136
130
147 75
19
206
23,8
M10; 17 deep
Y
A, B, A1, B1
M 33x2
A, B Service line ports 420 bar (6000 psi) high pressure series
SAE 3/4"
Brueninghaus Hydromatik
14/28
A2FM
RE 91 001/09.00
Shaft ends
Sizes 56, 63
Size 56
Sizes 56, 63
Size 56
A2FM
15/28
Brueninghaus Hydromatik
RE 91 001/09.00
78,5 32 20 10
45
45
T1
15
165
se
ep
ort
R 16
pla
140 h6
40
tes
18
83
15
29
38
T2
Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged)
13,5
165
61
M 18x1,5
02
166
SAE-ports, at side
18 9, 5
10
2,
Detail Y
60
57,2
57,2
104,5
27,8
25
99
B A
145
145
121
166
84
203
25
233
84
M12; 17 deep
162
196 257
160
M12; 17 deep
206 236
27,8
M12; 17 deep
Y
A, B Service line ports SAE 1" 420 bar (6000 psi) high pressure series
A, B Service line ports SAE 1" 420 bar (6000 psi) high pressure series
A, B Service line ports SAE 1" 420 bar (6000 psi) high pressure series
Brueninghaus Hydromatik
16/28
A2FM
57,2
57,2
A
57 ,2
25
27 ,8
RE 91 001/09.00
82,8 40 23 10
45
45
T1
se
18
190
ep
ort
R 20
pla
tes
20
160 h6
40
67
85
18
36,5
T2
50
Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged)
17,5
190
M 18x1,5
02
194
SAE-ports, at side
(Klammermae fr NG 107!)
2 31 22 ,8 (2 7, 8
10
Detail Y
4
66,7
66,7
66 ,7 32 (57 (2 ,2) 5)
70
)
110
31,8
B
120 159
A
136 157
B
194 99 66,7
32
181
225,5 252
32
99
M14; 19 deep
178
213 285
226 261
M14; 19 deep
A
31,8
A, B Service line ports SAE 1 1/ 4" 420 bar (6000 psi) high pressure series
A, B Service line ports SAE 11/4"(1") 420 bar (6000 psi) high pressure series
A, B Service line ports SAE 11/4" 420 bar (6000 psi) high pressure series
Shaft ends Sizes 107, 125 Size 107 Sizes 107, 125 Size 107
A2FM
17/28
Brueninghaus Hydromatik
66.7
RE 91 001/09.00
93 40 25 10
45
45
T1
19
210
se
,5
ep
ort
R 20
pla
180 h6
40
77
95,5
19,5
22
37,2
T2
1 8
Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged)
17,5
210
tes
,5
M 22x1,5
02
194
SAE-ports, at side
23 31 ,8
10
Detail Y
4
66,7
66,7
31,8
B
134 188
B
121
70
A
149 185
B
66,7
32
66 32
,7
194 99
252 294
32
99
M14; 19 deep
237 294
202
252 290
M14; 19 deep
M14; 19 deep
31,8
A, B Service line ports SAE 1 1 / 4" 420 bar (6000 psi) high pressure series
A, B Service line ports SAE 11/4" 420 bar (6000 psi) high pressure series
Y A, B Service line ports SAE 11/4" 420 bar (6000 psi) high pressure series
Shaft ends Sizes 160, 180 Size160 Sizes 160, 180 Size 160
Brueninghaus Hydromatik
18/28
A2FM
66,7
188
RE 91 001/09.00
45
40 9
45
104
32
T
15
see
por
236
t pl
200 -0,029
25
92
22
ates
102,5
15
211
25
32
Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged)
236
M 22x1,5
B
84
A
31,8
165
284 309
32 99
M14; 19 deep
A, B Service line ports 420 bar (6000 psi) high pressure series
SAE 11/4"
Shaft ends
A2FM
19/28
Brueninghaus Hydromatik
RE 91 001/09.00
50 9
82
22
246
45
T
105
45
224 h8
105
263
0 28
172
25 82
22
Connections A, B Service line ports (see port plates) T1, T2 Drain ports (1 port plugged) U Port for bearing flushing (plugged)
246
124
M 22x1,5 M 14x1,5
02
SAE-ports, at side
267 236
31,8
M14; 19 deep
210
93
32 66, 7
32 314 50 50
32
M14; 19 deep
323
SAE 11/4"
172
82
SAE 11/4"
04
Shaft ends
A1 A
210
172
22 325
85
A, B A1, B1
M 48x2 M 48x2
Brueninghaus Hydromatik
20/28
A2FM
210
RE 91 001/09.00
Port plate 01
50 14 83 23,5
320
2230
45
335
T
128
36 0
280 h8
26 3
102
18
128
198
28 83
T
350
36,6
36,6
Detail X
B
Port plate 10 Detail X
M14; 22 deep
A
79,4 245
MB B
66,7
MB
40
60
MA
40 60
250
241 120
148
199
M16; 21 deep
32
323 370,5
MA
X
31,8
port plate 01 port plate 10 Drain ports ( 1 port plugged) Port for bearing flushing (plugged) Test ports operating pressure (plugged)
Shaft ends Z Splined shaft, DIN 5480 W 60x2x30x28x9g pN = 350 bar P Parallel shaft with key, DIN 6885, AS 18x11x100 pN = 350 bar
A2FM
21/28
Brueninghaus Hydromatik
335
32
170
RE 91 001/09.00
361,5 50 14 98 27,5
2230
45
375
T
142
40
315 h8
22
112,5
26 3
142
36
220
30 111
T
396
Detail X
A MA
79,4 270
M16; 21 deep
Connections A, B Service line ports high pressure series T Drain ports (1 port plugged) U Port for bearing flushing (plugged) MA, MB Test ports operating pressure (plugged)
MB
SAE 11/2" M 33x2 M 18x1,5 M 14x1,5
40 65 65 40
Shaft ends Z Splined shaft, DIN 5480 W 70x3x30x22x9g pN = 350 bar P Parallel shaft with key, DIN 6885, AS 20x12x100 pN = 350 bar
Brueninghaus Hydromatik
22/28
375
A2FM
192
RE 91 001/09.00
2230
T
236
0
45
465
183
50
400 h8
1830
102
45
183
252
35 156
T
507
Detail X
344
44,5
44,5
A
MA
96,8 340
M20; 30 deep
Connections A, B Service line ports High pressure series T Drain port (plugged) U Port for bearing flushing (plugged) MA, MB Test ports operating pressure (plugged)
MB
SAE 2" M 42x2 M 18x1,5 M 14x1,5
50 85 85
50
Shaft ends Z Splined shaft, DIN 5480 W 90x3x30x28x9g pN = 350 bar P Parallel shaft with key, DIN 6885, AS 25x14x125 pN = 350 bar
A2FM
23/28
Brueninghaus Hydromatik
465
22
RE 91 001/09.00
2230
45
465
T
183
50 0
400 h8
22
143
263
183
45
279
35 156
T
512
X
Detail X
344
44,5
44,5
MA
Connections A, B Service line ports high pressure series T Drain ports (1 port plugged) U Port for bearing flushing (plugged) MA, MB Test ports operating pressure (plugged) SAE 2" M 42x2 M 18x1,5 M 14x1,5
MB
M20; 30 deep
50 85 85
50
Shaft ends Z Splined shaft, DIN 5480 W 90x3x30x28x9g pN = 350 bar P Parallel shaft with key, DIN 6885, AS 25x14x125 pN = 350 bar
Brueninghaus Hydromatik
24/28
96,8
340
465
236
A2FM
RE 91 001/09.00
Flushing valves
Built-on flushing and boost pressure relief valve (7) This valve is built on to the fixed displacement motor. It must then be noted that only a port plate with ports at side is then available (port plate 02). The flushing and boost pressure relief valve has a fixed setting of 16 bar (the setting of the primary boost pressure relief valve must be noted) and is used to safeguard the minimum boost pressure. A fixed flow of fluid is taken via an orifice from the low A (B) T2 pressure side of the circuit and fed into the motor housing. This flow is then passed back to tank with the case drain fluid. Fluid thus removed from the closed circuit must be T1 B (A) made up by means of the boost pump.
A1
Size Flushing flow (at low pressure p = 25 bar) * 45, 56, 63 3,5 L/min Orifice-No.: 651766/503.12.01.01 80, 90 5 L/min Orifice-No.: 419695/503.12.01.01 107, 125 8 L/min Orifice-No.: 419696/503.12.01.01 160, 180 10 L/min Orifice-No.: 419697/503.12.01.01 250 10 L/min * Standard flushing volumes (for sizes 45180 flushing volumes of 3,5 - 10 L/min can be supplied. If a flushing volume different from the standard flushing volume is required, please indicate the requested orifice in clear text when ordering).
Integrated flushing valve (6) (Size 23...90) The valve is integrated into the port plate.
A
T2
A (B)
Y
A2
B
T1 B (A)
- switching pressure p 8 bar (this value is lower than the starting pressure of an unloaded motor). - closed in centre position (p < 8 bar). Flushing flow (at low pressure p = 25 bar) 2,5 L/min 3,1 L/min 4,1 L/min
98
Speed sensor
Version A2FMD ("suitable for fitting speed sensor") includes gearing on the rotary group and in addition the port M or D (M18x1,5), in which a speed sensor is screwed in. A speed-proportional signal is produced by means of the rotating, splined rotary group which can be picked up by a suitable sensor and fed back for evaluation. Sizes 23...180
A1
Sizes 23, 28, 32 45 56, 63 80, 90 107, 125 160, 180 250 355 500 710...1000
length of thread 12,7 11,2 14,7 14,7 14,7 14,7 variable variable variable variable
Sizes 250...1000
30
M (M18x1,5)
D (M18x1,5)
A2
A2
The speed sensor is not included in standard supply. Suitable sensors (order seperately!): - Induktive impulse detector ID (see RE 95130) (only for sizes 23...180) - Hall effect speed sensor HD (see RE 95134)
A2FM
25/28
Brueninghaus Hydromatik
RE 91 001/09.00
The pressure relief valves MHDB (as to RE 64642) are protecting the motor against overcharge. As soon as the set opening pressure is reached the oil is flowing from the high pressure side to the low pressure side. Setting range opening pressure _______________ 50 420 bar At design with pressure sequence range (2) a higher pressure setting can be realized by applying an external pilot pressure of 25 30 bar at port pSt. Please indicate in clear when ordering : - opening pressure of the pressure relief valve - opening pressure at pilot pressure applied at pSt (for design 2 only)
D1 D2 D5
T2 MB Y
Detail Y
D7 D6
D3
Z S1
Detail Z D8
pSt MB
T2
B
S1
A
D9
B
D10 D12
A
pSt MA T1
D13
D11
MB
only for port plate 18
Fixed Displacement Motor A2FM, with integrated pressure relief valve (with pressure sequence range) Sizes 28, 32 45 56, 63 80, 90 107, 125 160, 180 Ports A, B SAE 3/4" SAE 3/4" SAE 3/4" SAE 1" S1 M 22x1,5 M 22x1,5 M 26x1,5 M 26x1,5 MA , MB M 20x1,5 M 20x1,5 M 26x1,5 M 26x1,5 M 26x1,5 M 30x1,5 pSt G 1/4 G 1/4 G 1/4 G 1/4 G 1/4 G 1/4
Connections A, B Service line ports S1 Boosting (only for port plate 19) MA, MB Test ports (plugged) pSt Pilot pressure port (only for design 2)
D3 25 22 19 10 5
D4 63 60 57 55 48 43
D8 36 36 42 42 53 53
D9 66 66 75 75 84 84
D12 19 19 19 25 32 32
D13 M10; 17 deep M10; 17 deep M10; 13 deep M12; 18 deep M14; 19 deep M14; 19 deep
243,5 17,5
149,5 130
Brueninghaus Hydromatik
26/28
A2FM
D4
T1
pSt
MA
SAE
RE 91 001/09.00
For hydro-motors operating in open loop the motion control valve BVD (as to RE 95522) is avoiding an overspeed and thus a lack of filling. A lack of filling occurs at the hydro-motors as soon as the speed of the drive from external is exceeding the speed corresponding to the added volume flow. The motion control valve is not included in the type code of the A2FM motor and has to be indicated separately when ordering. At shipment it is fixed at the motor with 2 tacking bolts (do not remove the tacking bolts during fixing of the service lines). At separated shipment of motion control valve and motor the motion control valve has to be fixed in a first step with the added tacking bolts to the cover plate of the motor. The final fixing of the motion control valve at the motor is effected in both cases by fitting the service lines ( observe screw-in depth B4 + B12 and B13)!
MB B S Gext A
B7 B6
B1 B3
T
B12
B5
T2
A,B
Detail Y
Y
B13
B
tacking bolts (M6)
B8 B9
MA
T1
B10
A
B11
Fixed displacement motor A2FM, motion control valve BVD and integrated pressure relief valve Sizes 28, 32 45 56, 63 80, 90 ports BVD20..16 BVD20..16 BVD20..17 BVD20..27 A, B SAE 3/4" SAE 3/4" SAE 3/4" SAE 1" SAE 11/4" SAE 11/4" B1 BVD20..16 BVD20..16 BVD20..17 BVD20..27 209 229 250 271 298 332 B2 180 191 192 202 255 S M 22x1,5 M 22x1,5 M 22x1,5 M 22x1,5 M 27x2 M 27x2 B3 174 187 208 229 285 B4
1 1
Connections A, B Service line ports SAE S Boosting (plugged) MA,MB Test ports (plugged)
107, 125 BVD25..38 160, 180 BVD25..38 Sizes 28, 32 45 56, 63 80, 90
B7
B8 66 66 75 75
B9
B10 B11
B12
B4
MB
23,8 50,8 19 23,8 50,8 19 23,8 50,8 19 27,8 57,2 25 31,8 66,7 32 31,8 66,7 32
M10; 17 deep M10; 14 deep M10; 17 deep M10; 14 deep M10; 17 deep M10; 14 deep M12; 18 deep M12; 16 deep M14; 19 deep M14; 19 deep M14; 19 deep M14; 19 deep
234,5 251
A2FM
27/28
Brueninghaus Hydromatik
B2
B13
RE 91 001/09.00
Installation on top of tank level Motor on top of min. oil level in the tank Actions as installation below tank level Installation position 1 and 2: If the motor is left at standstill for a long period, the oil in the housing chamber may fully drain out through the operating lines (air entering via the shaft seal). Consequently, on restarting, the bearings will be insufficiently lubricated. You should therefore refill the axial piston unit via the highest positioned drain port before restarting (Installation position 2: air bleed via port R or U). Installation position 2 (shaft on top) In this installation position, the bearings will be insufficiently lubricated even if the housing chamber is only partially drained. To prevent oil draining via the drain port, insert a check valve in the drain line (opening pressure 0.5 bar).
T1 T2
2
0,5 bar
* *
R(U)
T2
T1 T2
*
R(U) T1 T2
Brueninghaus Hydromatik GmbH Elchingen Plant Glockeraustrae 2 D89275 Elchingen Phone +49 (0) 73 08 82-0 Telefax +49 (0) 73 08 72 74 Horb Plant An den Kelterwiesen 14 D72160 Horb Phone +49 (0) 74 51 92-0 Telefax +49 (0) 74 51 82 21 The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract. All rights reserved - Subject to revision
A2FM