General Description
Delta’s LYTE DIN rail power supply series is designed for cost sensitive users who need to fulfill essential features needed for many
general industrial applications, without compromising on quality and reliability. The convection-cooled LYTE series will operate
between -20°C to +70°C, with full rated power available from -10°C to +50°C at 230Vac. The overcurrent protection is designed to
operate in constant current mode, which makes the LYTE series suitable for inductive and capacitive load applications. The product is
certified according to safety standards IEC/EN/UL 60950-1 & IEC/EN/UL 62368-1 for Information Technology Equipment (ITE) and UL
508 for Industrial Control Equipment (ICE). Electromagnetic radiated and conducted emissions are compliant to EN 55032, Class B;
and, the product is RoHS compliant for environmental protection.
Model Information
LYTE DIN Rail Power Supply
Model Number Input Voltage Range Rated Output Voltage Rated Output Current
DRL-24V480W1A 85-264 Vac (120-375 Vdc) 24 Vdc 20.0 A
Model Numbering
DR L– 24V 480W 1 A
DIN Rail Product Type Output Voltage Output Power Single Phase Delta A – Without DC OK Contact
L – LYTE Series Standard S – With DC OK Relay Contact
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
1 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Specifications
Input Ratings / Characteristics
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
2 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Mechanical
Environment
Protections
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
3 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Reliability Data
MTBF Telcordia SR-332 > 700,000 hrs I/P: 100 Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time 10 years (115 Vac & 230 Vac, 50% load @ 40°C)
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
4 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
EMC
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
5 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Block Diagram
DRL-24V480W1AA
DRL-24V480W1AS
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
6 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Device Description
Dimensions
H x W x D: 123.6 x 85.5 x 128.5 mm (4.87 x 3.37 x 5.06 inch)
DRL-24V480W1AA
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
7 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
DRL-24V480W1AS
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
8 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Engineering Data
Output Load De-rating VS Surrounding Air Temperature Note
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
9 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
The power supply unit (PSU) can be mounted on 35 mm DIN rails in accordance with EN 60715. The device should be installed with
input terminal block at the bottom.
Mounting Dismounting
Snap on the DIN rail as shown in Fig. 2.1: To uninstall, pull or slide down the latch with screw driver as
1. Tilt the unit upwards and insert it onto the DIN rail. shown in Fig. 2.2. Then slide the power supply unit (PSU) in the
2. Push downwards until stopped. opposite direction, release the latch and pull out the power supply
3. Press against the bottom front side for locking. unit (PSU) from the rail.
4. Shake the unit slightly to ensure that it is secured.
In accordance to EN 60950 / UL 60950 and EN 62368 / UL 62368, flexible cables require ferrules.
Use appropriate copper cables designed to sustain operating temperature of at least 60°C / 75°C or more to fulfill UL requirements.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
10 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Safety Instructions
Vertical Mounting
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
11 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Functions
Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
Start-up Time
The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied.
Rise Time
The time required for the output voltage to change from 10% to 90% of its final steady state set value.
Hold-up Time
Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
12 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Overload & Overcurrent Protections (Continuous Current) Overvoltage Protection (Latch Mode)
The power supply’s Overload (OLP) and Overcurrent (OCP) The power supply’s overvoltage circuit will be activated when its
Protections will be activated when output current is 109~130% of internal feedback circuit fails. The output voltage shall not exceed
IO (Max load). Upon such an occurrence, the VO (output voltage) its specifications as described in “Protections” section. Power
will start to droop. Once the power supply has reached its supply will latch off, and require removal/re-application of input
maximum power limit, the protection will be activated; and, the AC voltage in order to restart.
power supply will operate in continuous current. The power
supply will recover once the cause of OLP or OCP is removed, The power supply should be latch.
and IO (output current) is back within the specified range.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
13 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Operating Mode
Redundant Operation
In order to ensure proper redundant operation for the
power supply units (PSUs), the output voltage difference
between the two units must be kept at 0.45~0.5 V for
these 24 V supplies. Follow simple steps given below to
set them up for the redundant operation:
Step 1.
Measure output voltage of PSU 1 and PSU 2. If PSU 1 is
the master unit, then VO of PSU 1 must be higher than
PSU 2.
Step 2.
Connect the power supply units PSU 1 and PSU 2 to Vin 1
& Vin 2, respectively, of the DRR-40N (or 40 A) module
**The Signal GND in the DRR module is for the built-in LED and DC OK signals. The
shown on the right of above diagram. Output GND terminals from the two PSU’s do not need to be connected to the Signal GND
terminal.
\Step 3.
Connect the system load to Vout. Please note that output Fig. 3 Redundant Operation Connection Diagram
voltage Vout from DRR module will be = VO (output voltage
of power supply) – Vdrop* (in DRR module).
*Vdrop will vary from 0.60 V to 0.90 V (Typical 0.65 V) depending on the
load current and surrounding air temperature.
Parallel Operation
The power supply units (PSUs) can also be used for parallel
operation in order to increase the output power. The
difference in output voltage between the two units must be
kept to within 25 mV of each other. This difference must be
verified with the same output load connected independently
to each unit.
Parameters such as EMI, inrush current, leakage current,
PARD, start up time will be different from those on the
datasheet, when two units are connected in parallel. The
user will need to verify that any differences will still allow the
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
14 www.DeltaPSU.com (February 2022, Rev. 07)
TECHINCAL DATASHEET
Others
Conformal Coating
The Protective Coating Technology
Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including
under device, and prevents leakage. The conformal coating dipping can be applied to PCBAs or circuit board.
The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants
such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem
especially in highly conversing atmosphere.
Attention
Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for
using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail
(please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim
or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of
using the product before placing an order with Delta.
Delta reserves the right to make changes to the information described in the datasheets without notice.
Authorized Representatives
The Netherlands United Kingdom
Delta Greentech (Netherlands) B.V. Delta Electronics Europe Limited
Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands 1 Redwood Court, Peel Park Campus,
East Kilbride, Glasgow, G74 5PF, United Kingdom
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
15 www.DeltaPSU.com (February 2022, Rev. 07)