GRUNDFOS DATA BOOKLET

Unilift CC, KP, AP and KP Basic


Submersible drainage and effluent pumps
50 Hz
Unilift CC, KP, AP and KP Basic

1. Product overview 3
Table of contents

Unilift CC, KP, AP 3

2. General data 4
Performance range 4
Applications 5
Examples of applications 5
Wastewater definitions 6
Pump overview 6
Type keys 6
Construction 7
Installation 7

3. Technical data and performance curves 8


Unilift CC 8
Unilift KP 12
Unilift AP12 16
KP Basic 21
Unilift AP35 27
Unilift AP35B 32
Unilift AP50 37
Unilift AP50B 42

4. Controllers 47
Control box 47
Level controller 47
LC 107, LCD 107 48
LC 108, LCD 108 50
LC 110, LCD 110 51

5. Accessories 53
Accessories for Unilift CC, KP, AP pumps 53
Level controllers and accessories 54
Accessories for controllers 56

6. Product range 57
Unilift CC 57
Unilift KP 150 58
Unilift KP 250 59
Unilift KP 350 60
Unilift AP12 61
Unilift AP35 62
Unilift AP35B 62
Unilift AP50 63
Unilift AP50B 63
KP Basic 64

7. Further product information 65


WebCAPS 65
WinCAPS 66
GO CAPS 67

2
Unilift CC, KP, AP and KP Basic
1

1. Product overview

Product overview
Unilift CC, KP, AP
Application Technical data Sizing

Unilift CC
• Max. flow rate, Q: 14 m3/h
• Max. head, H: 9 m
Unilift CC is a submersible pump designed for pumping

TM03 1883 3305


• Liquid temp.: 0 °C to +40 °C
clean, non-aggressive water and slightly dirty (grey) • Max. particle size: 10
wastewater. Unilift CC can pump down to 3 mm water • Material: Composite

GR A0682
level and can be used in permanent installations or as a • Low suction to 3 mm.
portable pump.

Unilift KP

• Max. flow rate, Q: 14 m3/h


• Max. head, H: 9 m

TM03 1884 3305


Unilift KP is a submersible pump designed for pumping • Liquid temp.: 0 °C to +50 °C
clean, non-aggressive water and slightly dirty (grey) • Max. particle size: 10
wastewater such as domestic effluents from septic and • Material: Stainless steel.

GR 0110
sludge treating systems.
Drainage

Unilift AP12

• Max. flow rate, Q: 32 m3/h


• Max. head, H: 17 m
TM03 1851 3205

TM03 1885 3305


Unilift AP12 is a submersible pump designed for pumping • Liquid temp.: 0 °C to +55 °C
clean, non-aggressive water and slightly dirty (grey) • Max. particle size: 12
wastewater. The pump can be used as a portable unit. • Material: Stainless steel.

KP Basic

• Max. flow rate, Q: 16 m3/h


• Max. head, H: 10.8 m

TM05 7072 0513


KP Basic is a submersible pump designed for pumping • Liquid temp.: 0 °C to +40 °C
clean, non-aggressive water and slightly dirty (grey) • Max. particle size: 10
• Material: Technopolymer.
GR 7913

wastewater.

Unilift AP35

• Max. flow rate, Q: 18 m3/h


• Max. head, H: 11 m

TM03 1886 3305


TM00 5739 1195

Unilift AP35 is a submersible pump designed for pumping • Liquid temp.: 0 °C to +55 °C
dirty water, untreated wastewater (excluding toilet • Max. particle size: 35
discharge) and liquids containing fibres from light industry, • Material: Stainless steel.
laundries, etc. with particles up to ∅35.
Effluent

Unilift AP35B
• Max. flow rate, Q: 21 m3/h
• Max. head, H: 13 m
Unilift AP35B is a submersible pump designed for
TM03 8259 0907

TM03 1888 3305

• Liquid temp.: 0 °C to +40 °C


pumping effluents (excluding toilet discharge). The pump • Max. particle size: 35
is suitable for installation on auto coupling; this allows • Material: Stainless steel
easy access to the pump for maintenance and other • Optional: Auto coupling.
purposes.

Unilift AP50

• Max. flow rate, Q: 32 m3/h


• Max. head, H: 12 m
TM00 5740 1495

TM03 1887 3305

Unilift AP50 is a submersible pump designed for pumping • Liquid temp.: 0 °C to +55 °C
dirty water, untreated wastewater and liquids containing • Max. particle size: 50
fibres from light industry, laundries, etc. with particles up
Domestic sewage

• Material: Stainless steel.


to 50.

Unilift AP50B
• Max. flow rate, Q: 31 m3/h
• Max. head, H: 17 m
TM03 8260 0907

TM03 1889 3305

Unilift AP50B is a submersible pump designed for • Liquid temp.: 0 °C to +40 °C


pumping effluents. The pump is suitable for installation on • Max. particle size: 50
auto coupling allowing easy access to the pump for • Material: Stainless steel
maintenance and other purposes. • Optional: Auto coupling.

3
2 Unilift CC, KP, AP and KP Basic

2. General data
General data

Performance range
H H
[m] [m]
9 Unilift CC 9 Unilift KP
8 Drainage pumps 8 Drainage pumps
7 7
6 6
5 5
4 4
3 3
2 2
1 1

TM03 1363 1805


TM03 1364 1805
0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q [l/s] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q [l/s]

0 2 4 6 8 10 12 Q [m³/h] 0 2 4 6 8 10 12 Q [m³/h]

H H
[m] [m]
18 Unilift AP12 12
Unilift AP35/50
16 Drainage pumps 11
10
Wastewater and
14 sewage pumps
9
12 8
10 7
AP

6
8
50

5
6 4
AP

4 3
35

2 2
1
TM03 1362 1805

TM00 3547 1805


0
0
0 1 2 3 4 5 6 7 8 9 Q [l/s]
0 1 2 3 4 5 6 7 8 9 10 Q [l/s]
0 5 10 15 20 25 30 Q [m³/h]
0 5 10 15 20 25 30 35 Q [m³/h]

H H
[m] [m]
18 Unilift AP35B/50B 10 KPBasic
16 Wastewater and 9 Drainage pumps
14 sewage pumps 8

12 7
6
10
AP50B 5
8
4
6
3
4
AP35B 2
2 1
TM01 9544 1805

TM05 5871 4112

0 0
0 1 2 3 4 5 6 7 8 9 Q [l/s] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [l/s]

0 5 10 15 20 25 30 Q [m³/h] 0 2 4 6 8 10 12 14 Q [m³/h]

4
Unilift CC, KP, AP and KP Basic
2
Applications

General data
The Unilift CC, KP and AP are submersible drainage
pumps suitable for temporary as well as permanent
free-standing installation. Furthermore, Unilift AP35B
and AP50B pumps are suitable for installation on an
auto coupling at the bottom of a collecting tank with
guide rails going to the top.
The pumps are designed for intermittent operation.
pH values:
• Unilift CC: 4 to 9
• Unilift KP: 4 to 9
• Unilift AP: 4 to 10.
Maximum density: 1,100 kg/m3.
Maximum installation
depth below water level: 10 m.
For permanent installation, level controllers are
available: LC 107, LC 108 and LC 110 for one-pump
installations and LCD 107, LCD 108 and LCD 110 for
two-pump installations.

Examples of applications
Unilift pump type
Applications
CC KP AP12 KPB AP35 AP35B AP50 AP50B
Max. liquid temperature [°C] 40 50 55 40 55 40 55 40
Max. particle size [mm] 10 10 12 10 35 35 50 50
Non-permanent, light-duty applications (used as a portable pump) ● ● ❍ ● ❍ ❍ ❍ ❍
Non-permanent, heavy-duty applications for installers and light industry
● ● ● ● ●
(used as a portable pump)
Pumping of:
Water and rainwater in horticulture ● ● ● ●
Water from rivers and lakes ● ● ● ● ● ● ● ●
Rainwater, drainage water and water from flooding ● ● ● ● ● ● ● ●
Water for filling/emptying containers, ponds, tanks, etc. ● ● ● ● ● ● ● ●
Effluents from showers, washing machines and sinks below sewer
● ● ● ● ● ● ● ●
level
Pool water ● ● ● ● ● ● ● ●
Ditch drainage water ● ● ● ● ● ● ● ●
Groundwater (lowering applications) ● ● ● ● ● ● ● ●
Domestic effluents from septic and sludge-treating systems ❍ ● ● ❍ ● ● ● ●
Liquids containing fibres from light industry, laundries, etc. ● ● ● ●
Effluents from viaducts, underpasses, etc. ● ● ● ●
Drainage water from garage sprinkler systems ❍ ❍ ❍ ❍
Domestic wastewater with toilet discharge from pipes and water
● ●
closets below sewer level, outdoor pump installations
Domestic wastewater with toilet discharge from pipes and water
Not applicable, use Multilift
closets below sewer level, indoor pump installations
● = Recommended pump type
❍ = Alternative pump type

5
2 Unilift CC, KP, AP and KP Basic

Wastewater definitions Type keys


General data

Drainage Unilift CC pumps


Raw water, drainage and untreated wastewater
Example Unilift CC 9 A1
containing solids no larger than 12 mm from
households, farms and small industry. Type range
Type
Effluent Maximum head [m]
5
Dirty water and untreated wastewater (excluding toilet 7
discharge), containing fibres and solids no larger than 9
50 mm from dewatering systems, domestic wastewater Operation
systems and small industry. A1 = Automatic operation
M1 = Manual operation

Sewage Unilift KP pumps


Untreated wastewater and raw sewage containing
fibres, textiles and other solids, including toilet dis- Example Unilift KP 150 A 1
charge from domestic sewage systems, farms and Type range
industry.
Rated motor output, P2 [W]:
To avoid clogging, pumps allowing free passage of 150
solids up to 70-80 mm are recommended. Be aware 250
350
that toilet discharge often contains foreign bodies such
Level control:
as nappies, tampons, toilet rolls, children’s toys and S = with integrated, electronic sensor
toothbrushes. (automatic operation)
A = with float switch
(automatic operation)
Pump overview M = without level switch
(manual operation)
Motor:
Pump range Free passage Number of 1 = single-phase
Impeller type
Unilift [mm] motor poles 3 = three-phase
CC 10 Semi-open 2
KP 10 Semi-open 2 Unilift AP pumps
AP12 12 Semi-open 2
KP Basic 10 Semi-open 2 Example Unilift AP 35 B. 50. 08. A 1 .V
AP35 35 Vortex 2
AP35B 35 Vortex 2 Type range
AP50 50 Vortex 2 Maximum solids size [mm]
AP50B 50 Vortex 2 Pump type:
Blank = AP pump
B = AP Basic
Nominal diameter of discharge port
Power output P2 /100 [W]
Level control:
A = Automatic operation (with float switch)
Blank = Manual operation (without float switch)
Motor:
1 = Single-phase
3 = Three-phase
Impeller:
V = Vortex impeller

6
Unilift CC, KP, AP and KP Basic
2
Construction

General data
Vertical, single-stage, submersible centrifugal pumps
with horizontal or vertical discharge port designed for
free-standing installation, installation by means of an
auto-coupling guide rail system or installation in
collecting tanks.
The pumps are directly connected to an asynchronous
submersible motor for 1 x 230 V + 6/- 10 %, 3 x 230 V
+ 6/- 10 % or 3 x 400 V + 6/- 10 %, 50 Hz.
Enclosure class: IP68
Insulation class: B or F.
Unilift pumps
Single-phase pumps incorporate thermal overload
protection and require no additional motor protection.
Three-phase pumps must be connected to a motor
starter.

Installation
The pumps are suitable for free-standing installation.
Unilift AP35B and AP50B can be installed on an auto-
coupling guide rail system, available as an accessory.
Pumps for vertical dry tank installation can be installed
by means of a stationary stand with suction bend.

7
3 Unilift CC, KP, AP and KP Basic

3. Technical data and performance curves


Technical data and performance curves

Unilift CC Components included


The pump is supplied with an adapter, a non-return
valve and a 90 ° bend.
The adapter has 3/4", 1" and 1 1/4" external threads.
It must be cut to fit the discharge pipe.
The non-return valve can be fitted in the adapter to
prevent backflow through the pump when it stops.
The 90 ° bend has 1 1/4" internal threads and is
intended for use on the side discharge outlet.

TM06 0686 0714


Pump and motor sleeve
The pump and motor sleeve are both made of
composite material cast in one piece with a 1 1/4"
external pipe thread (G) discharge connection. A slot
Fig. 1 Unilift CC
on the handle holds the float switch cable.
Unilift CC 5, CC 7 and CC 9 pumps are single-stage The mains cable and float switch cables are lead into
submersible pumps capable of pumping down to 3 mm the motor sleeve through hermetically sealed cable
water level. The pumps have both a top and a side entries.
outlet allowing easy adaptation to existing pipework. The suction strainer is fitted to the pump sleeve by
The pumps are designed for pumping rainwater and giving it a light push, and it can be removed easily by
grey wastewater from: means of a screwdriver or similar tool. The water
• washing machines, bath tubs, showers, sinks, etc. enters the pump through the holes of the suction
from low-lying parts of buildings up to sewer level strainer preventing the passage of large solids.
• cellars or buildings prone to flooding The large holes also ensure a slow flow into the pump.
• draining wells Suction to low water level is obtained by removing the
• collecting wells for surface water with inlets from strainer.
roof gutters, tunnels, etc.
Motor
• swimming pools, ponds or fountains.
The motor is a single-phase, asynchronous, dry-rotor
The pumps are suitable for permanent installation or
motor. The axial rotor position is secured by means of
they can be used as portable pumps. They are
a ball bearing. The motor is cooled by the pumped
available in two versions:
liquid around the motor.
• M for manual operation
• A for automatic operation. Insulation class Enclosure class

The pumps allow free passage of particles up to Unilift CC 5 B IP68


∅10 mm. Unilift CC 7 F IP68

Unilift CC 9 B IP68
Approvals
VDE, GOST and LGA according to DIN EN 12050-2. The motor incorporates automatic overload protection
cutting out the motor in case of overload. When cooled
Pumped liquids to normal temperature, the motor will restart
automatically.
The pumps are suitable for these liquids:
• clean, non-aggressive water
• slightly dirty (grey) wastewater.
The pumps are not suitable for these liquids:
• liquids containing long fibres
• inflammable liquids (oil, petrol, etc.)
• aggressive liquids.
If the pump has been used for other liquids than clean
water, it should be flushed through with clean water
immediately after use.
A special version where all wetted parts are made of
stainless steel, EN 1.4401, and suction strainer of
composite is available for slightly aggressive liquids,
such as salt water or chlorinated water below 20 °C.

8
Unilift CC, KP, AP and KP Basic
3
Selection Example: A DN 32 discharge pipe with an inner

Technical data and performance curves


diameter of 26 to 34 mm (depending on local
The overview below is suitable for the selection of the
standards) requires a minimum flow velocity of
correct size of Unilift CC pumps used in stationary
approximately 2 m3/h.
applications.
The overview below shows the maximum lengths of
The flow velocity through the discharge pipe must be
combined vertical and horizontal DN 32 discharge
minimum 0.7 m/s to ensure self-cleaning.
pipes.

TM03 1370 1805

The overview is only intended as a guide. Grundfos is


not liable for installations not complying with the
overview.
Note: If the non-return valve is used, the pressure drop
in the valve is 0.2 m head at 2 m3/h, which is to be
subtracted from the vertical pipe lengths.
The vertical height of the discharge pipe should be
measured from the pump stop level.

9
3 Unilift CC, KP, AP and KP Basic

Performance curves
Technical data and performance curves

H
[m]
Unilift CC
10 50 Hz
-9

-7
7

-5
5

TM03 1346 1805


0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Q [m³/h]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [l/s]
The broken line represents a min. flow velocity of 0.7 m/s with a DN 32 discharge pipe to DIN EN 12056.
Using the side outlet may result in up to 5 % drop in performance.

Operating conditions Adjustment of cable length for float


Liquid temperature switch
0 °C to +40 °C. The difference in level between start and stop can be
adjusted by changing the free cable length between
However, at intervals of at least 30 minutes, the pump
the float switch and the pump handle.
is allowed to run at maximum +70 °C for periods not
exceeding two minutes. • Increasing the free cable length results in fewer
starts/stops and a large difference in level.
Installation • Reducing the free cable length results in more
The pump can be used in the vertical position as well frequent starts/stops and a small difference in level.
as in the tilted or horizontal position with the discharge In order for the float switch to start and stop the pump,
port as the highest point of the pump. The suction the free cable length must be minimum 100 mm and
strainer must be covered by the pumped liquid. maximum 200 mm.

Start
TM00 1111 1005

TM03 0829 0505

Stop

Fig. 2 Pump positions

Installation depth
Maximum 10 metres below the water surface. Fig. 3 Start-stop level, Unilift CC

Cable length (L) Cable length (L)


min. 100 mm max. 200 mm
Pump type
Start Stop Start Stop
[mm] [mm] [mm] [mm]
Unilift CC 5 350 115 400 55
Unilift CC 7 350 115 400 55
Unilift CC 9 385 150 435 90

10
Unilift CC, KP, AP and KP Basic
3
Technical data

Technical data and performance curves


Dimensions [mm]
Voltage P1 In Weight
Pump type H H
[V] [W] [A] B [kg]
Top discharge Side discharge
Unilift CC 5 1 x 220/240 240 1.1 520 350 400 4.35
Unilift CC 7 1 x 220/240 380 1.7 520 350 400 4.6
Unilift CC 9 1 x 220-240 780 3.7 570 400 500 6.5

With float switch Without float switch

133
105
H

1" 1/4 GAS

306.6
270

TM060739 0814
TM03 1122 1105

137.5
90
B
160

238

Fig. 4 Minimum well dimensions, Unilift CC Fig. 6 Pump dimensions

If the pump is installed in a collecting well, the The space required corresponds to the physical
minimum dimensions of the well should be as shown dimensions of the pump.
above to ensure free movability of the float switch.
Materials
Installation in narrow pit Standard version
If the Unilift CC pump is to be installed in a narrow pit,
it is available with a level arm bracket. Component Material DIN W. - Nr.

The minimum narrow pit dimensions are 300 x 350 mm. Motor sleeve PP 15 GF
Pump sleeve PP 15 GF
Impeller PP 20 GF
Suction strainer Stainless steel, class A2 1.4301
V-ring NBR 50
O-rings NBR 70
H05RN-F 3G0.75 (CC 5)
Cable
H07RN-F3G1 (CC 7 - CC 9)

Special versions

Component Material DIN W. - Nr.


Motor sleeve PP 15 GF
TM06 0696 0714

Pump sleeve PP 15 GF
Impeller PP 20 GF
Suction strainer PP 15 GF
V-ring NBR 50
O-rings NBR 70
Fig. 5 Unilift CC with level arm bracket mounted
Wetted motor parts Stainless steel, class 2 1.4401
H05RN-F 3G0.75 (CC 5)
Cable
H07RN-F3G1 (CC 7 - CC 9)

11
3 Unilift CC, KP, AP and KP Basic

Unilift KP Pumped liquids


Technical data and performance curves

The pump is suitable for these liquids:


• clean, non-aggressive water
• slightly dirty (grey) wastewater.
The open-impeller design ensures free passage of
solids up to ∅10.

Functions
Unilift KP-A

TM01 7145 4099


Unilift KP-A features automatic start/stop operation by
means of a float switch.
Unilift KP-AV
Unilift KP-AV features automatic start/stop operation
Fig. 7 Unilift KP-A by means of a vertical level switch.
Unilift KP is a single-stage, submersible, stainless Unilift KP-M
steel drainage pump in compact design with Unilift KP-M features manual operation by means of
hermetically sealed stator housing (canned motor). external start/stop.
The pump can be installed in a permanent installation
or used as a portable pump. It may be operated fully or Construction
partially submerged.
The stainless steel pump sleeve is made in one piece
The pump is suitable for these applications: with Rp 1 1/4 discharge port and insulating handle.
• pumping in drainage collecting wells Unilift KP have a watertight vulcanized plug.
• pumping of wastewater without discharge from Liquid enters the pump through the holes of the
toilets suction strainer. The holes of the strainer prevent the
• drainage of flooded cellars or buildings passage of large solids.
• emptying of swimming pools, tanks and fountains The sturdy impeller has single-curved vanes.
• applications within agriculture, horticulture, dairies, The bevelled front edges prevent fibres from jamming
breweries and the process industry. the impeller.
The guide vanes of the pump housing guide the liquid,
Versions lifting sand grains into the liquid flow. This prevents
The Unilift KP pump series comes in these versions: sand from blocking the impeller.
• Unilift KP-A with float switch Motor
(automatic operation) The motor is a single-phase or three-phase,
• Unilift KP-AV with vertical level switch asynchronous canned motor with liquid-filled rotor
(automatic operation) chamber and water-lubricated bearings. The motor is
• Unilift KP-M without level switch cooled by the pumped liquid around the motor.
(manual operation) Enclosure class: IP68
Insulation class: F
Approvals
The motor incorporates automatic overload protection.
CE, LGA, VDE, GS, EMV, GOST, UL, CSA and In case of overload, the motor stops automatically.
C-TICK. When cooled, the motor restarts automatically.

12
Unilift CC, KP, AP and KP Basic
3
Selection Example: A DN 32 discharge pipe with an inner

Technical data and performance curves


diameter of 26 to 34 mm (depending on local standard)
The overview below is suitable for the selection of the
requires a minimum flow velocity of approximately
correct size of Unilift KP pumps used in stationary
2.3 m3/h.
applications.
The overview below shows the maximum lengths of
The flow velocity through the discharge pipe must be
combined vertical and horizontal DN 32 discharge
minimum 0.7 m/s to ensure self-cleaning.
pipes.

TM03 1643 2505

The overview is only intended as a guide. Grundfos is


not liable for installations not complying with the
overview.
Note: If the non-return valve is used, the pressure
drop in the valve is 0.2 m head. The pressure drop is to
be subtracted from the vertical pipe lengths.
The vertical height of the discharge pipe should be
measured from the pump stop level.

13
3 Unilift CC, KP, AP and KP Basic

Operating conditions Level switches


Technical data and performance curves

Installation depth: Max. 10 metres below liquid level A level switch starts and stops the pump between two
Min. liquid temperature: 0 °C liquid levels. This type of installation requires a non-
Max. liquid temperature at return valve in the discharge pipe or the pump.
50 °C*
continuous operation: Unilift KP pumps are available with two different level
* At intervals of at least 30 minutes, the pump is allowed, however, to switch types.
run at maximum +70 °C for periods not exceeding 2 minutes.
During continuous operation, the suction strainer must Unilift KP-A with float switch
always be completely covered by the liquid. A clamp on the pump handle holds the float switch
cable. The difference in level between start and stop
Installation can be adjusted by changing the free cable length
between pump handle and float switch.
If Unilift KP is installed in a collecting well, the
minimum well dimensions must be as shown in the L
figures below.
Start

‹ ‹
‹ ‹ ‹
‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹

‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹

‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹
‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹

‹‹‹‹‹‹‹
‹ ‹ ‹ ‹ ‹ ‹

‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹

‹ ‹ ‹
‹ ‹



‹ ‹

‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹

‹ ‹
‹ ‹
‹ ‹
‹ ‹ ‹

‹ ‹

‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹

‹ ‹

‹ ‹

‹ ‹ ‹

‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹
‹ ‹ ‹



‹ ‹
‹ ‹ ‹ ‹

‹ ‹‹
‹ ‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹

‹ ‹


‹ ‹

‹ ‹
‹ ‹

Stop


‹ ‹

‹ ‹

‹‹‹‹‹‹‹‹ ‹

‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹

‹ ‹
‹ ‹
‹ ‹ ‹

‹ ‹

‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹

‹ ‹

‹ ‹

‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹‹
‹ ‹ ‹
‹ ‹ ‹





400 mm
‹ ‹
‹ ‹

‹ ‹ ‹ ‹


H

‹ ‹

TM03 4446 2106


‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹



‹ ‹ ‹
‹ ‹

‹ ‹

‹ ‹


‹ ‹
‹ ‹
‹ ‹
‹ ‹ ‹

‹ ‹


‹ ‹

‹ ‹

‹ ‹

‹ ‹ ‹ ‹


‹ ‹
‹ ‹ ‹ ‹

‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹

‹ ‹

‹ ‹ ‹


‹ ‹
‹ ‹

‹ ‹
‹ ‹


‹ ‹

‹ ‹

‹ ‹
‹ ‹

TM03 4445 2106

‹ ‹
‹ ‹
‹ ‹ ‹

‹ ‹ ‹

‹ ‹
‹ ‹

‹ ‹

‹ ‹ ‹






‹ ‹ ‹
‹ ‹

‹ ‹ ‹
‹ ‹

‹ ‹

‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹



‹ ‹ ‹
‹ ‹



‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹

350B mm
Fig. 11 Start/stop levels at min. and max. cable lengths,
Unilift KP-A
Fig. 8 Minimum well dimensions, Unilift KP-A
Cable length Cable length
(L) (L)
Pump type min. 70 mm max. 150 mm




• •



• • •

• •







Start Stop Start Stop
[mm] [mm] [mm] [mm]
• • •
• • •
• •
• • • •

• •
• • • • • • •
• • • • •
• • • •

• • •
• • • • • • • • •
• • •
• • •
• • • • • •
• • •
• • • •
• •
• • • • • •
• •
• • • •
• • • • • •
• • •
• • • •

• •


• • •

• •

• •

• •

Unilift KP 150 A
• •
• •
• •
• •



290 140 335 100


• • • •


• •



• • •

Unilift KP 250 A

• •
• •

• •

• •






• •

Unilift KP 350 A 300 150 345 110



• •
• •
• •

• •

• • • •

• • •
• •


• •
• •

• • •

• •
• •

• •

400 mm


• •
• •
• •
• • • •

• • • •

• •

Unilift KP AV with vertical level switch




• • •


• •

• •
• •
• •
• •
• •



• •
• • •


• •



• • •

• •


For pumps with vertical level switch, the difference in




• •

• •
• •




• •



• •


• •
• •
• •

• •

• • • •

level between start and stop is not adjustable.


• • •
• •


• •
• •

• •



• • •

• •

• •

• •
TM01 1109 1098

• •
• •
• • • •

• • • •

• •

Dimensions for Unilift KP 350 are marked with an " ★ ".



• • •

• •

• • • • • • • • •
• • • • • •
• • • • • •
• • • • • •
• • • • • •
• • • • • • •
• • • • • • • • • • • • • • •
• • • • • •
• • • • • •
• • • • • •
• • • • • •
• • •
• • • • • • • • • • • •
• • •
• • • • • •
• • •
• • • • • •
• • •
• • • • • •
• • • • • • • • • • • • •
• • •
• • • • • • • • •
• • • • • • • • •
• • •
• • •

Vertical level switch


ø 250 mm

Fig. 9 Minimum well dimensions, Unilift KP-AV

Pump positioning
Unilift KP-M and Unilift KP-A can be used in the
vertical position with the discharge port uppermost or Start
Start
in the horizontal or tilted position with the discharge 80 mm
80 mm
port as the highest point of the pump. Stop
Stop
TM01 1108 3297

Unilift KP-AV must be used in the vertical position. 100 mm


100mm
110 mm★
TM00 1548 0493

Fig. 12 Start/stop levels for Unilift KP AV

Fig. 10 Pump positions

14
Unilift CC, KP, AP and KP Basic
3
Performance curves

Technical data and performance curves


p H
[kPa] [m]
9
KP 350 Unilift KP
50 Hz
80 ISO 9906 Annex A
8
KP 250

60 6
KP 150
5

40 4

20 2

0 0

TM03 1593 2505


0 2 4 6 8 10 12 Q [m³/h]

0 1 2 3 Q [l/s]
The broken line shows a minimum flow velocity of 0.7 m/s with a DN 32 discharge pipe to DIN EN 12056.

Supply voltage Power P1 Current, I n Power factor Speed Capacitor


Pump type
[V] [W] [A] [Cos φ] [min-1] [μF]
Unilift KP 150 1 x 220-230
300 1.3 0.99 2900 8
Unilift KP 150 1 x 230-240
Unilift KP 250 1 x 220-230 2.3
480
Unilift KP 250 1 x 230-240 2.2 0.97 2900 8
Unilift KP 250 3 x 380-415 480 (415 V) 0.8
Unilift KP 350 1 x 220-240 3.2
700 0.99 2900 8
Unilift KP 350 3 x 380-400 1.3

Pump dimensions Materials


Component Material DIN W. - Nr. AISI

Rp 1 1
4
Pump sleeve Stainless steel 1.4301 304
Pump housing Stainless steel 1.4301 304
Suction strainer Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Shaft Stainless steel 1.4057 431
226

Stator housing Stainless steel 1.4301 304


220

Guide vanes Stainless steel 1.4301 304


Bearings Carbon
O-rings NBR
Seal rings NBR
140 H07RN-F 3 G 1
Cables
H07RN-F 4 G 1
30
TM00 1642 1093

148

Fig. 13 Pump dimensions

15
3 Unilift CC, KP, AP and KP Basic

Unilift AP12 Pump sleeve and housing


Technical data and performance curves

The stainless steel pump sleeve is made in one piece


and equipped with an insulated carrying handle.
The suction strainer is clipped on to the pump housing
for easy removal in connection with maintenance.
The strainer prevents the passage of large solids and
ensures a slow flow into the pump. As a result, most
impurities are prevented from entering the pump.
The stainless steel pump housing is fitted with an
internal riser pipe ensuring high efficiency.
The riser pipe has a number of holes enabling efficient

TM00 5738 0895


cooling of the motor during operation. The cable entry
is of the socket and plug connection type for quick and
easy dismantling.

Discharge port
Fig. 14 Unilift AP12
All Unilift AP12 pumps have a threaded vertical
The Unilift AP12 pump is a single-stage submersible discharge port.
pump designed for pumping drainage water. Unilift AP12.40: Rp 1 1/2
The pump is suitable for these applications: Unilift AP12.50: Rp 2.
• groundwater lowering
• pumping in drainage collecting wells Shaft and bearings
• pumping in surface water collecting wells with inflow The stainless steel shaft rotates in maintenance-free
from roof gutters, shafts, tunnels, etc. prelubricated ball bearings.
• emptying ponds, tanks, etc.
Impeller
Maximum particle size: 12 mm.
The stainless steel impeller is a semi-open impeller
Liquid temperature range: 0 °C to +55 °C.
with L-shaped blades and a clearance of 12 mm.
The blades are curved backwards to reduce any
Approvals
harmful effect from solid particles and to minimise
VDE, LGA, UL and CSA. power consumption.

Automatic operation
The pump is available for automatic as well as manual

TM00 5477 0895


operation and can be installed in a permanent
installation or used as a portable pump. The pump is
available in these versions:
• with float switch fitted for automatic on/off operation
between two liquid levels (single-phase pumps) Fig. 15 Impeller, Unilift AP12
• with separate level switch and control box for
automatic on/off operation between two liquid levels Shaft seal
(three-phase pumps) The shaft seal is a combination of a mechanical
• without level switch for manual on/off operation. bellows shaft seal and a lip seal with 60 ml oil
Pumps fitted with float switch can also be used for between. Seal faces are made of silicone carbide.
manual on/off operation. In this case, the float switch
must be secured in an upward-pointing position.

16
Unilift CC, KP, AP and KP Basic
3
Motor

Technical data and performance curves


The motor is a single- or three-phase asynchronous
dry-rotor motor.
Enclosure class: IP68
Insulation class: F (155 °C)
Cable type: H07RN-F.
Single-phase motors have built-in thermal protection.

Materials
Component Material DIN W. - Nr. AISI
Pump housing Stainless steel 1.4301 304
Riser pipe Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Pump sleeve Stainless steel 1.4401 316
Pump shaft - wet end Stainless steel 1.4301 304
Bearings Heavy-duty prelubricated ball bearings
O-rings NBR rubber
Screws Stainless steel 1.4301 304
Oil Shell Ondina 15, non-toxic

17
3 Unilift CC, KP, AP and KP Basic

Selection • use steel pipes


Technical data and performance curves

The overview below is suitable for the selection of the • the minimum flow velocity through the vertical
correct size of Unilift AP12 pumps used in stationary discharge pipe must be 1 m/s (1 1/2" for AP12.40.xx
applications. and 2" for AP12.50.11)
To ensure that the discharge pipe is self-cleaning, the • the minimum flow velocity through the horizontal
calculation of the pipe lengths is based on these discharge pipe must be 0.7 m/s (2" for AP12.40.xx
requirements: and 2 1/2" for AP12.50.11).

TM03 1878 3305


The overview is only intended as a guide. Grundfos is
not liable for installations not complying with the
overview.
Note: If the non-return valve is used, the pressure
drop in the valve is 0.2 m head, which is to be
subtracted from the vertical pipe lengths.
The vertical height of the discharge pipe should be
measured from the pump stop level.

18
Unilift CC, KP, AP and KP Basic
3
Performance curves Dimensional sketch

Technical data and performance curves


p
[kPa]
H
[m]
AP12
B
160 50 Hz
16 .50
.11
.3 ISO 9906 +/- 10%
S
14 .50
.1 1.1

120 .4
12 0.
08

.4
0 .0
10 6

.4
80 0.
8 04

A
40 4

TM00 5523 0995


2

0 0
0 5 10 15 20 25 30 35 Q [m³/h]

0 2 4 6 8 10 Q [l/s]

P1 P1
[hp] [kW]
.50.11.3 Fig. 16 Pump dimensions
2.0

.50.11.1
1.6
2

1.2 .40.08
TM00 7212 0803

.40.06
0.8 .40.04
1

0.4

0 0.0
0 5 10 15 20 25 30 35 Q [m³/h]

I start Dimensions [mm]


Voltage P1 P2 In --------- Weight
Pump type Cos φ In
[V] [kW] [kW] [A] A B S [kg]

Unilift AP12.40.04.1 1 x 230 0.7 0.4 3.0 0.99 3.8 321 216 Rp 1 1/2 11.0
Unilift AP12.40.04.A1 1 x 230 0.7 0.4 3.0 0.99 3.8 321 216 Rp 1 1/2 11.0
Unilift AP12.40.04.3 3 x 230 0.7 0.4 2.2 0.85 4.7 321 216 Rp 1 1/2 9.7
Unilift AP12.40.04.A.3 3 x 230 0.7 0.4 2.2 0.85 4.7 321 216 Rp 1 1/2 12.0
Unilift AP12.40.04.3 3 x 400 0.7 0.4 1.2 0.83 5.0 321 216 Rp 1 1/2 9.7
Unilift AP12.40.04.A.3 3 x 400 0.7 0.4 1.2 0.83 5.0 321 216 Rp 1 1/2 12.0
Unilift AP12.40.06.1 1 x 230 0.9 0.6 4.4 0.99 3.8 321 216 Rp 1 1/2 11.0
Unilift AP12.40.06.A.1 1 x 230 0.9 0.6 4.4 0.99 3.8 321 216 Rp 1 1/2 11.0
Unilift AP12.40.06.3 3 x 230 0.9 0.6 2.9 0.83 5.4 321 216 Rp 1 1/2 10.7
Unilift AP12.40.06.A.3 3 x 230 0.9 0.6 2.9 0.83 5.4 321 216 Rp 1 1/2 13.0
Unilift AP12.40.06.3 3 x 400 0.9 0.6 1.6 0.83 4.8 321 216 Rp 1 1/2 10.7
Unilift AP12.40.06.A.3 3 x 400 0.9 0.6 1.6 0.83 4.8 321 216 Rp 1 1/2 10.7
Unilift AP12.40.08.1 1 x 230 1.3 0.8 5.9 0.99 3.8 346 216 Rp 1 1/2 12.6
Unilift AP12.40.08.A.1 1 x 230 1.3 0.8 5.9 0.99 3.8 346 216 Rp 1 1/2 12.6
Unilift AP12.40.08.3 3 x 230 1.2 0.8 3.7 0.85 4.7 346 216 Rp 1 1/2 12.0
Unilift AP12.40.08.A.3 3 x 230 1.2 0.8 3.7 0.85 4.7 346 216 Rp 1 1/2 14.3
Unilift AP12.40.08.3 3 x 400 1.2 0.8 2.1 0.87 4.9 346 216 Rp 1 1/2 12.0
Unilift AP12.40.08.A.3 3 x 400 1.2 0.8 2.1 0.87 4.9 346 216 Rp 1 1/2 14.3
Unilift AP12.50.11.1 1 x 230 1.7 1.1 8.5 0.92 3.8 357 241 Rp 2 15.1
Unilift AP12.50.11.A.1 1 x 230 1.7 1.1 8.5 0.92 3.8 357 241 Rp 2 15.1
Unilift AP12.50.11.3 3 x 230 1.9 1.2 6.4 0.85 3.6 357 241 Rp 2 15.6
Unilift AP12.50.11.A.3 3 x 230 1.9 1.2 6.4 0.85 3.6 357 241 Rp 2 17.9
Unilift AP12.50.11.3 3 x 400 1.9 1.2 3.2 0.88 4.6 357 241 Rp 2 15.6
Unilift AP12.50.11.A.3 3 x 400 1.9 1.2 3.2 0.88 4.6 357 241 Rp 2 17.9

19
3 Unilift CC, KP, AP and KP Basic

Unilift AP12 installations


Technical data and performance curves

600
Min. 600

Start
start
min.

Stop
stop

TM00 5539 0995


TM03 1896 3305

min. ∅800
Min.ø800
min. ∅550
ø550
Min.

Fig. 18 Two-pump installation with four float switches


Fig. 17 One-pump installation with float switch

Adjustment of cable length for float switch Two-pump installation

The difference in level between start and stop can be The Unilift AP pumps can be used for parallel
adjusted by changing the free cable length between installation together with a controlller.
the float switch and the pump handle. The example shows an installation with four float
• Increasing the free cable length results in fewer switches. The pumps are controlled by the liquid level
starts/stops and a large difference in level. in the tank.
• Reducing the free cable length results in more When the liquid lifts up the second float switch from the
starts/stops and a small difference in level. bottom, the first pump will start.
In order for the float switch to start and stop the pump, If the liquid rises faster than one pump can manage,
the free cable length must be min. 100 mm and max. the third float switch from the bottom will be lifted up
350 mm. and start the second pump.
When the bottom float switch is no longer lifted up by
Cable length Cable length the liquid, the settable stop delay will set in and after
min. 100 mm max. 350 mm
Pump type that both pumps will be stopped.
Start Stop Start Stop
[mm] [mm] [mm] [mm]
When the top float switch is lifted up by the liquid, the
high-level alarm will be activated.
Unilift AP12 500 300 550 100

20
Unilift CC, KP, AP and KP Basic
3
KP Basic Constructional features

Technical data and performance curves


Pump
Water-resistant technopolymer pump sleeve, impeller
and suction strainer. Stainless steel motor housing,
rotor shaft and screws.
Triple "O" ring seals interposed with oil chamber.
Motor
The motor is a continuous-duty, submersible induction
motor. The stator is fitted in an airtight stainless steel
motor housing encasing cabling, microswitch and
capacitor. The rotor is mounted on oversized, greased
and sealed-for-life ball bearings selected to guarantee
silent running and long life. The pump has built-in
thermal and current overload protection and a
capacitor which is permanently in circuit in the single-

Gr7913
phase version.
KP Basic 200: Supplied as standard with 10 metres
Fig. 19 KP Basic of H05 RN-F power cable.
KP Basic 300 A: Supplied as standard with 10 metres
The submersible pump from the KP Basic series is of H05 RN-F power cable.
designed mainly for automatically operated, fixed Note: 5 m cable on request.
domestic applications for draining basements and
KP Basic 600: Supplied as standard with 10 metres
garages which are subject to flooding. of H07 RN-F power cable.
Thanks to its compact, easy-to-handle design, it can KP Basic 600 A: Supplied as standard with 10 metres
also be used as a portable pump for emergencies such of H07 RN-F power cable.
as lifting water from tanks or rivers, emptying Note: 5 m cable on request.
swimming pools, fountains, excavations and
Enclosure class: IP68
underpasses.
Insulation class: F
It is also ideal for gardening and hobbies in general.
Manufactured according to EN 60335-2-41.
The level switch allows fixed installation and
guarantees automatic pump operation. Standard voltage: 1 x 220-240 V, 50 Hz
3 x 380-415 V, 50 Hz.
Table of performance ranges and possible applications KP Basic
DNM connections Rp 1 1/2
Flow rate Q [m3/h] Max. 16
Head H [m] Max. 10.8
Temperature t [°C] Max. +40
Rain water l
Clean wastewater l

21
3 Unilift CC, KP, AP and KP Basic

Descriptions and materials


Technical data and performance curves

29
1 54
73
78 TM02 8468 3204

79 32 4
Fig. 20 Materials KP Basic

Pos. Descriptions Materials


1 Pump sleeve Noryl GFN 2
4 Impeller Noryl GFN 2
29 O-ring NBR
32 Stop ring Stainless steel 12E
Motor
Stainless steel AISI 304
– Motor housing
54 X5 CrNi 1810
Stainless steel AISI 304
– Rotor
X5 CrNi 1810
78 Pressure disc Noryl GFN 2
79 Suction strainer Noryl GFN 2

22
Unilift CC, KP, AP and KP Basic
3
Selection Example: A DN 32 discharge pipe with an inner

Technical data and performance curves


diameter of 26 to 34 mm (depending on local
The overview below is suitable for the selection of the
standards) requires a minimum flow velocity of
correct size of KP Basic pumps used in stationary
approximately 2 m3/h.
applications.
The overview below shows the maximum lengths of
The flow velocity through the discharge pipe must be
combined vertical and horizontal DN 32 discharge
minimum 0.7 m/s to ensure self-cleaning.
pipes.

TM05 7071 0513

KP Basic 200 KP Basic 300 KP Basic 600


The overview is only intended as a guide. Grundfos is
not liable for installations not complying with the
overview.
Note: If the non-return valve is used, the pressure drop
in the valve is 0.2 m head at 2 m3/h, which is to be
subtracted from the vertical pipe lengths.
The vertical height of the discharge pipe should be
measured from the pump stop level.

23
3 Unilift CC, KP, AP and KP Basic

Performance range
Technical data and performance curves

p H
[kPa] [m]
10.5 KPBasic
100 50 Hz
10.0 600 (A)

9.5
90
9.0

8.5
80
8.0

7.5
70
7.0
300 A
6.5
60
6.0

5.5 200

50 5.0

4.5
40 4.0

3.5
30 3.0

2.5

20 2.0

1.5

10 1.0

0.5

0 0.0

TM02 8937 1804


0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m³/h]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]
Fig. 21 Performance range for KP Basic

Curve conditions
The performance curves are based on the kinematic
viscosity values = 1 mm2/s and density equal to
1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.

24
Unilift CC, KP, AP and KP Basic
3
Technical data KP Basic 300 A

Technical data and performance curves


Operating range: From 1 to 16 m3/h with head up to
10.2 m
Liquid temperature range: From 0 °C to +35 °C
Liquid quality requirements: Grey wastewater without fibres
Maximum ambient temperature: +40 °C
Maximum suction depth: 8m
KP Basic 200 5 mm
Maximum particle size through KP Basic 300A 10 mm
the suction strainer: KP Basic 600 10 mm
KP Basic 600A 10 mm
KP Basic 200 8 mm

TM02 9100 0513


KP Basic 300A 85 mm
Minimum suction level:
KP Basic 600 38 mm
KP Basic 600A 175 mm
Fixed or portable in a vertical
position. Fig. 22 Minimum dimension for the pit for KP Basic
The minimum pit dimensions for
Installation:
fixed installation with automatic
300 A with automatic float switch
operation are stated in figs 22 and
23. KP Basic 600 A
Maximum submersion depth: 7m
Maximum dry running time: 1 minute
Automatic float switch: Type name extension A
Special versions on request: Other voltages and/or frequencies.

TM02 9101 0513


Fig. 23 Minimum dimension for the pit for KP Basic
600 A with automatic float switch

25
3 Unilift CC, KP, AP and KP Basic

KP Basic 200, KP Basic 300A


Technical data and performance curves

Electrical data

P1 P2 P2 I1/1 Capacitor
Voltage
Pump type Max.
[V] [kW] [hp] [A] [μF] [Vc]
[kW]
KP Basic 200 1 x 220-240 350 0.22 0.3 1.5 8 450
H1

Start
H

KP Basic 300A 1 x 220-240 350 0.22 0.3 1.5 8 450

Stop
H2

TM02 8466 1713


B
A
D

Fig. 24 Dimensions KP Basic 200 and 300A


Dimensions and weight

Dimensions [mm] Stop Start Packing dimensions [mm] Volume Weight


Pump type DNM
A B D E H H1 H2 [mm] [mm] L/A L/B L/H [m3] [kg]

KP Basic 200 185 140 225 82 266 390 38.5 100 350 Rp 1 1/4 207 227 312 0.016 4.5
KP Basic 300A 185 140 225 82 275 390 47.5 100 350 Rp 1 1/4 207 227 312 0.016 4.6

KP Basic 600, KP Basic 600A


Electrical data

P1 P2 P2 I1/1 Capacitor
Voltage
Pump type Max.
[V] [kW] [hp] [A] [μF] [Vc]
[kW]
KP Basic 600 1 x 220-240 800 0.55 0.75 3.4 14 450
H1

Start
H

KP Basic 600A 1 x 220-240 800 0.55 0.75 3.4 14 450


Stop

KP Basic 600 3 x 380-415 800 0.55 0.75 3.4 - -


H2

E
TM02 8466 1713

B
A
D

Fig. 25 Dimensions KP Basic 600 and 600A


Dimensions and Weight

Dimensions [mm] Stop Start Packing dimensions [mm] Volume Weight


Pump type DNM
A B D E H H1 H2 [mm] [mm] L/A L/B L/H [m3] [kg]

KP Basic 600 200 160 225 90 376 490 73 200 450 Rp 1 1/4 207 227 422 0.021 7
KP Basic 600A 200 160 225 90 376 490 73 200 450 Rp 1 1/4 207 227 422 0.021 6.7

26
Unilift CC, KP, AP and KP Basic
3
Unilift AP35 Pump sleeve and housing

Technical data and performance curves


The stainless steel pump sleeve is made in one piece
and equipped with an insulated carrying handle.
The suction strainer is clipped on to the pump housing
for easy removal in connection with maintenance.
The strainer prevents the passage of large solids and
ensures a slow flow into the pump.
The stainless steel pump housing is fitted with an
internal riser pipe ensuring high efficiency. The riser
pipe has a number of holes enabling efficient cooling
of the motor during operation. The cable entry is of the

TM00 5739 1195


socket and plug connection type, allowing for quick
and easy dismantling.

Discharge port
Fig. 26 Unilift AP35 All Unilift AP35 pumps have a threaded Rp 1 1/2
vertical discharge port.
The Unilift AP35 pump is a single-stage, submersible
pump designed for pumping drainage water and
Shaft and bearings
effluent. The pump is suitable for these applications:
• groundwater lowering The stainless steel shaft rotates in maintenance-free
prelubricated ball bearings.
• pumping in drainage collecting wells
• pumping in surface water collecting wells with inflow Impeller
from roof gutters, shafts, tunnels, etc.
The stainless steel impeller is a vortex impeller with
• emptying of ponds, tanks, etc. L-shaped blades and a clearance of 35 mm in the
• pumping of fibre-containing wastewater from pump housing. The blades are curved backwards to
laundries and industries reduce any harmful effect from solid particles and to
• pumping of domestic wastewater without discharge minimise power consumption. The impeller has a
from water closets. protective cap to prevent the deposit of long-fibred
Liquid temperature range: 0 °C to +55 °C. material.

Approvals

TM00 5478 0895


VDE, LGA, UL and CSA.

Automatic operation
The pump is available for automatic as well as manual
operation and can be installed in a permanent Fig. 27 Impeller, Unilift AP35
installation or used as a portable pump. The pump is
available in these versions: Shaft seal
• with float switch fitted for automatic on/off operation The shaft seal is a combination of a mechanical,
between two liquid levels (single-phase pumps) bellows shaft seal and a lip seal with 60 ml oil
• with separate level switch and control box for between. Seal faces are made of silicone carbide.
automatic on/off operation between two liquid levels
(three-phase pumps)
• without level switch for manual on/off operation.
Pumps fitted with float switch can also be used for
manual on/off operation. In this case the float switch
must be secured in an upward-pointing position.

27
3 Unilift CC, KP, AP and KP Basic

Motor cable
Technical data and performance curves

The motor is a single- or three-phase asynchronous


dry-rotor motor.
Enclosure class: IP68
Insulation class: F (155 °C)
Cable type: H07RN-F.
Single-phase motors have built-in thermal protection.

Materials
Component Materials DIN W. - Nr. AISI
Pump housing Stainless steel 1.4301 304
Riser pipe Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Pump sleeve Stainless steel 1.4401 316
Pump shaft - wet end Stainless steel 1.4301 304
Bearings Heavy-duty prelubricated ball bearings
O-rings NBR rubber
Screws Stainless steel 1.4301 304
Cables Neoprene
Oil Shell Ondina 15, non-toxic

28
Unilift CC, KP, AP and KP Basic
3
Selection • use steel pipes

Technical data and performance curves


The overview below is suitable for the selection of the • the minimum flow velocity through the vertical
correct size of Unilift AP35 pumps used in stationary discharge pipe (1 1/2") must be 1 m/s
applications. • the minimum flow velocity through the horizontal
To ensure that the discharge pipe is self-cleaning, the discharge pipe (2") must be 0.7 m/s.
calculation of the pipe lengths is based on these
requirements:

TM03 1879 3305

The overview is only intended as a guide. Grundfos is


not liable for installations not complying with the
overview.
Note: If the non-return valve is used, the pressure
drop in the valve is 0.2 m head, which is to be
subtracted from the vertical pipe lengths.
The vertical height of the discharge pipe should be
measured from the pump stop level.

29
3 Unilift CC, KP, AP and KP Basic

Performance curves Dimensional sketch


Technical data and performance curves

p H B
[kPa] [m]
AP
35
AP35
11 .4

100
0.0
8 .V
50 Hz
ISO 9906 Annex A
S
10
AP
35
.40
9 .0
6.V

80
8

60 6

A
40 4

TM00 5524 0995


20 2

0 0
0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

0 1 2 3 4 5 6 Q [l/s]

P1 P1 Fig. 28 Pump dimensions


[hp] [kW] AP35.40.08.V
1.2
1.5
1.0
AP35.40.06.V
0.8
1.0
TM00 7219 0803

0.6

0.5 0.4

0.2

0.0 0.0
0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

I start Dimensions [mm]


Voltage P1 P2 In --------- Weight
Pump type Cos φ In
[V] [kW] [kW] [A] A B S [kg]

Unilift AP35.40.06.1.V 1 x 230 0.9 0.6 4.0 0.97 4.1 376 216 Rp 1 1/2 11.4
Unilift AP35.40.06.A.1.V 1 x 230 0.9 0.6 4.0 0.97 4.1 376 216 Rp 1 1/2 11.4
Unilift AP35.40.06.3.V 3 x 230 0.9 0.6 3.0 0.85 5.2 376 216 Rp 1 1/2 11.1
Unilift AP35.40.06.A.3.V 3 x 230 0.9 0.6 3.0 0.85 5.2 376 216 Rp 1 1/2 13.4
Unilift AP35.40.06.3.V 3 x 400 0.9 0.6 1.6 0.83 4.8 376 216 Rp 1 1/2 11.1
Unilift AP35.40.06.A.3.V 3 x 400 0.9 0.6 1.6 0.83 4.8 376 216 Rp 1 1/2 13.4
Unilift AP35.40.08.1.V 1 x 230 1.2 0.7 5.5 0.98 4.0 410 216 Rp 1 1/2 12.7
Unilift AP35.40.08.A.1.V 1 x 230 1.2 0.7 5.5 0.98 4.0 410 216 Rp 1 1/2 12.7
Unilift AP35.40.08.3.V 3 x 230 1.1 0.7 3.6 0.85 5.3 410 216 Rp 1 1/2 12.1
Unilift AP35.40.08.A.3.V 3 x 230 1.1 0.7 3.6 0.85 5.3 410 216 Rp 1 1/2 14.4
Unilift AP35.40.08.3.V 3 x 400 1.1 0.7 2.0 0.86 5.1 410 216 Rp 1 1/2 12.1
Unilift AP35.40.08.A.3.V 3 x 400 1.1 0.7 2.0 0.86 5.1 410 216 Rp 1 1/2 14.4

30
Unilift CC, KP, AP and KP Basic
3
Unilift AP35 installations

Technical data and performance curves


600
Min. 600

Start
start
min.

Stop
stop

TM03 1898 3305


TM03 1897 3305

∅800
Min.ø800
min.
min. ∅550
Min.ø550

Fig. 29 One-pump installation with float switch Fig. 30 Two-pump installation with four float switches

Adjustment of cable length for float Two-pump installation


switch The Unilift AP pumps can be used for parallel
The difference in level between start and stop can be installation together with a controller.
adjusted by changing the free cable length between The example shows an installation with four float
the float switch and the pump handle. switches. The pumps are controlled by the liquid level
• Increasing the free cable length results in fewer in the tank.
starts/stops and a large difference in level. When the liquid lifts up the second float switch from the
• Reducing the free cable length results in more bottom, the first pump will start.
starts/stops and a small difference in level. If the liquid rises faster than one pump can manage,
In order for the float switch to start and stop the pump, the third float switch from the bottom will be lifted up
the free cable length must be min. 100 mm and max. and start the second pump.
350 mm. When the bottom float switch is no longer lifted up by
the liquid, the settable stop delay will set in and after
Cable length Cable length
min. 100 mm max. 350 mm
that both pumps will be stopped.
Pump type When the top float switch is lifted up by the liquid, the
Start Stop Start Stop
[mm] [mm] [mm] [mm] high-level alarm will be activated.
Unilift AP35 500 300 550 100

31
3 Unilift CC, KP, AP and KP Basic

Unilift AP35B Pump housing


Technical data and performance curves

Pump housing with an outstanding design for


submersible wastewater pumps, resulting in a high
head.
The pump housing is made of a steel tube with a
smooth surface and a hydraulically correct shape
ensuring free passage of particles.
Ring stand, pump inlet and pump housing are fastened
to the motor by means of four springs enabling quick
and easy dismantling.

Discharge port

TM03 8259 0907


All Unilift AP35B pumps have a threaded R 2
horizontal discharge port.

Shaft and bearings


Fig. 31 Unilift AP35B
The stainless steel shaft rotates in maintenance-free
The Unilift AP35B pump is a single-stage submersible prelubricated ball bearings.
pump designed for pumping effluent.
The pump is suitable for these applications: Impeller
• groundwater lowering The stainless steel impeller is a vortex impeller with
• pumping in drainage collecting wells L-shaped blades and a clearance of 35 mm in the
pump housing. The blades are curved backwards to
• pumping in surface water collecting wells with inflow
reduce any harmful effect from solid particles and to
from roof gutters, shafts, tunnels, etc.
minimise power consumption. The impeller has a
• emptying of ponds, tanks, etc. protective cap to prevent the deposit of long-fibred
• pumping of fibre-containing effluent from laundries material.
and industries
• pumping of domestic effluent from septic tanks and
sludge treating systems
• pumping of domestic effluent without discharge from

TM00 5478 0895


water closets.
Liquid temperature range: 0 °C to +40 °C.

Automatic operation
The pump is available for automatic as well as manual Fig. 32 Impeller, Unilift AP35B
operation and can be installed in a permanent
installation or used as a portable pump. The pump is Shaft seal
available in these versions: The shaft seal is a combination of a mechanical,
• with float switch fitted for automatic on/off operation bellows shaft seal and a lip seal with 80 ml oil
between two liquid levels (single-phase pumps) between. Seal faces are made of silicone carbide.
• without level switch for manual on/off operation.
Pumps fitted with float switch can also be used for
manual on/off operation. In this case, the float switch
must be secured in an upward-pointing position.

32
Unilift CC, KP, AP and KP Basic
3
Motor cable

Technical data and performance curves


The motor is a single- or three-phase asynchronous
dry-rotor motor.
Enclosure class: IP68
Insulation class: F (155 °C)
Cable type: H07RN-F.
Single-phase motors have built-in thermal protection.

Materials
Component Material DIN W. - Nr. AISI
Pump housing Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Washer Stainless steel 1.4301 304
Protective cap Novolen 2360 Kx
Parts in contact
Motor unit complete with liquid: 1.4401 316
Stainless steel
Pump shaft - wet end Stainless steel 1.4301 304
Motor cable Neoprene
O-rings NBR rubber
Spring Stainless steel 1.4310
Pump inlet Stainless steel 1.4301 304
Ring stand Polycarbonate
Oil Shell Ondina 15, non-toxic

33
3 Unilift CC, KP, AP and KP Basic

Selection • use steel pipes


Technical data and performance curves

The overview below is suitable for the selection of the • the minimum flow velocity through the vertical
correct size of Unilift AP35B pumps used in stationary discharge pipe (2") must be 1 m/s
applications. • the minimum flow velocity through the horizontal
To ensure that the discharge pipe is self-cleaning, the discharge pipe (2 1/2") must be 0.7 m/s.
calculation of the pipe lengths is based on these
requirements:

TM03 1881 3305


The overview is only intended as a guide. Grundfos is
not liable for installations not complying with the
overview.
The vertical height of the discharge pipe should be
measured from the pump stop level.

34
Unilift CC, KP, AP and KP Basic
3
Performance curves Dimensional sketch

Technical data and performance curves


p H
[kPa] [m]
13
AP35B
50 Hz
120
12 ISO 9906 Annex A
AP
35
B.5
11 0.0
8.1
100
10

80 8 AP
35
B.5
0.0
7 8 .3
AP
35
B.5

A
60 0.0
6 6.3

5
AP
35
B.5
0 .06
.1
S
40 4

20 2

TM03 4097 1806


1

C
0 0

D
0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

0 1 2 3 4 5 6 Q [l/s]

P1 P1
[hp] [kW]
1.2
AP35B.50.08.3 Fig. 33 Pump dimensions
1.6 AP35B.50.08.1

1.0 AP35B.50.06.3
1.2 AP35B.50.06.1
0.8
TM01 3580 0803

0.8 0.6

0.4
0.4
0.2

0.0 0.0
0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

I start Dimensions [mm]


Voltage P1 P2 In C --------- Weight
Pump type Cos φ In Cable length and plug
[V] [kW] [kW] [A] [μF] A C D S [kg]

Unilift AP35B.50.06.A1.V 1 x 230 1.0 0.66 4.4 0.98 3.1 13.8 443 116 73 R 2 8.5 5 m with Schuko plug
Unilift AP35B.50.06.1.V 1 x 230 1.0 0.66 4.4 0.98 3.1 13.8 443 116 73 R 2 8.5 10 m with Schuko plug
Unilift AP35B.50.06.3.V 3 x 400 1.0 0.63 1.55 0.89 5.2 8.0 443 116 73 R 2 7.4 5 m without plug
Unilift AP35B.50.08.A1.V 1 x 230 1.25 0.71 5.44 0.98 3.4 18.4 468 116 73 R 2 10.0 5 m with Schuko plug
Unilift AP35B.50.08.1.V 1 x 230 1.25 0.71 5.44 0.98 3.4 18.4 468 116 73 R 2 10.0 10 m with Schuko plug
Unilift AP35B.50.08.3.V 3 x 400 1.25 0.78 1.98 0.89 5.4 10.6 468 116 73 R 2 8.4 5 m without plug

Start/stop level
600
Min.600

Start
start
min.

Stop
stop
TM03 1914 3305

∅550
Min. ø550
min.

Fig. 34 Minimum well dimensions, Unilift AP35B

Start Stop
Pump type
[mm] [mm]
Unilift AP35B 633 270

35
3 Unilift CC, KP, AP and KP Basic

Unilift AP35B installations


Technical data and performance curves

A B

C D







• •
• •
• •
J

• •
• • •
• • •

• •
• • • •

Z

• • • • •

• •
• • • • •
• • •
• • • •
• • • • •• •
• •
• • • • • • • • • • • •
• • •
• • • • • •
• • • •
• • • • • • • •
• •
U

• • • •
• • • • • • • • • • • • •
• • • •
• •
• • •
• • • • •• • • • • • • • • •
• • • • •
• • • •
• • • • • • • • • •
• • • • • • •
• • • • •
• • • • • • •
• • • •
• • • • • • • • •
• • • •
• • •
• • • • • • • • •
• • •
• • • •
• • • •
• • • • • • •
• •
• • •

I
TM03 4194 1806

TM01 3592 0299


K L M M

N O P R P

Fig. 35 Dimensional sketch, one-pump installation on Fig. 36 Dimensional sketch, two-pump installation on
auto-coupling system auto-coupling system

One-pump installation on auto coupling


Dimensions [mm]
Pump type
A B C D E F G I J K L M N O P R S T U Z
Unilift AP35B.50.06 600 600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 3/4" 130 261
Unilift AP35B.50.08 ∅600 ∅600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 3/4" 130 261

Two-pump installation on auto coupling


Dimensions [mm]
Pump type
A B C D E F G I J K L M N O P R S T U Z
Unilift AP35B.50.06 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 3/4" 130 261
Unilift AP35B.50.08 600 600 304 135 82 85 26 100 76 150 400 200 300 700 35 330 R2 3/4" 130 261

36
Unilift CC, KP, AP and KP Basic
3
Unilift AP50 Pump sleeve and housing

Technical data and performance curves


The stainless steel pump sleeve is made in one piece
and equipped with an insulated carrying handle.
The suction strainer is clipped on to the pump housing
and can easily be removed for maintenance.
The strainer prevents the passage of large solids and
ensures a slow flow into the pump.
The stainless steel pump housing is fitted with an
internal riser pipe ensuring high efficiency. The riser
pipe has a number of holes enabling efficient cooling

TM00 5740 1495


of the motor during operation. The cable entry is of the
socket and plug connection type, allowing for quick
and easy dismantling.

Fig. 37 Unilift AP50 Discharge port


All Unilift AP50 pumps have a threaded Rp 2 vertical
The Unilift AP50 pump is a single-stage submersible discharge port.
pump designed for pumping effluent and sewage.
The pump is suitable for these applications: Shaft and bearings
• groundwater lowering The stainless steel shaft rotates in maintenance-free
• pumping in drainage collecting wells prelubricated ball bearings.
• pumping in surface water collecting wells with inflow
from roof gutters, shafts, tunnels, etc. Impeller
• emptying of ponds, tanks, etc. The stainless steel impeller is a vortex impeller with
• pumping of fibre-containing wastewater from L-shaped blades and a clearance of 50 mm in the
laundries and industries pump housing. The blades are curved backwards to
• pumping of domestic wastewater from septic tanks reduce any harmful effect from solid particles and to
and sludge treating systems minimise power consumption. The impeller has a
protective cap to prevent the deposit of long-fibred
• pumping of domestic wastewater with/without
material.
discharge from water closets.
Liquid temperature range: 0 °C to +55 °C.

Approvals

TM00 5477 0895


VDE, LGA, UL and CSA.

Automatic operation
The pump is available for automatic as well as manual Fig. 38 Impeller, Unilift AP50
operation and can be installed in a permanent
installation or used as a portable pump. The pump is Shaft seal
available in these versions: The shaft seal is a combination of a mechanical,
• with float switch fitted for automatic on/off operation bellows shaft seal and a lip seal with 60 ml oil
between two liquid levels (single-phase pumps) between. Seal faces are made of silicone carbide.
• with separate level switch and control box for
automatic on/off operation between two liquid levels
(three-phase pumps)
• without level switch for manual on/off operation.
Pumps fitted with float switch can also be used for
manual on/off operation. In this case, the float switch
must be secured in an upward-pointing position.

37
3 Unilift CC, KP, AP and KP Basic

Motor
Technical data and performance curves

The motor is a single- or three-phase asynchronous


dry-rotor motor.
Enclosure class: IP68
Insulation class: F (155 °C)
Cable type: H07RN-F.
Single-phase motors have built-in thermal protection.

Materials
Component Material DIN W. - Nr. AISI
Pump housing Stainless steel 1.4301 304
Riser pipe Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Pump sleeve Stainless steel 1.4401 316
Pump shaft - wet end Stainless steel 1.4301 304
Bearings Heavy-duty prelubricated ball bearings
O-rings NBR rubber
Screws Stainless steel 1.4301 304
Cables Neoprene
Oil Shell Ondina 15, non-toxic

38
Unilift CC, KP, AP and KP Basic
3
Selection • use steel pipes

Technical data and performance curves


The overview below is suitable for the selection of the • the minimum flow velocity through the vertical
correct size of Unilift AP50 pumps used in stationary discharge pipe (2") must be 1 m/s
applications. • the minimum flow velocity through the horizontal
To ensure that the discharge pipe is self-cleaning, the discharge pipe (2 1/2") must be 0.7 m/s.
calculation of the pipe lengths is based on these
requirements:

TM03 1880 3305

The overview is only intended as a guide. Grundfos is


not liable for installations not complying with the
overview.
Note: If the non-return valve is used, the pressure
drop in the valve is 0.2 m head, which is to be
subtracted from the vertical pipe lengths.
The vertical height of the discharge pipe should be
measured from the pump stop level.

39
3 Unilift CC, KP, AP and KP Basic

Performance curves Dimensional sketch


Technical data and performance curves

p
[kPa]
H
[m]
B
AP50
12
AP 50 Hz
11
50
.5 0.1
1.3 ISO 9906 Annex A S
AP V
50
100 .50
10 .11
.1 V

9 AP
50
.50
.0 8.V
80 8

60 6

A
40 4

TM00 5524 0995


20 2

0 0
0 4 8 12 16 20 24 28 32 Q [m³/h]

0 2 4 6 8 10 Q [l/s]

P1 P1
Fig. 39 Pump dimensions
[hp] [kW]

1.6
2

1V AP50.50.08.V
1.2 .5 0.11.
AP50
1 .3V
.50.1
TM00 7217 0803

AP50
0.8
1

0.4

0 0.0
0 4 8 12 16 20 24 28 32 Q [m³/h]

Voltage P1 P2 In I start Dimensions [mm] Weight


Pump type Cos φ ---------
[V] [kW] [kW] [A] In A B S [kg]

Unilift AP50.50.08.1.V 1 x 230 1.3 0.8 5.9 0.99 1.9 436 241 Rp 2 15.1
Unilift AP50.50.08.A.1.V 1 x 230 1.3 0.8 5.9 0.99 1.9 436 241 Rp 2 15.1
Unilift AP50.50.08.3.V 3 x 230 1.2 0.8 3.3 0.85 2.8 436 241 Rp 2 14.2
Unilift AP50.50.08.A.3.V 3 x 230 1.2 0.8 3.3 0.85 2.8 436 241 Rp 2 16.5
Unilift AP50.50.08.3.V 3 x 400 1.2 0.8 2.0 0.80 3.0 436 241 Rp 2 14.2
Unilift AP50.50.08.A.3.V 3 x 400 1.2 0.8 2.0 0.80 3.0 436 241 Rp 2 16.5
Unilift AP50.50.11.1.V 1 x 230 1.6 1.1 8.0 0.92 4.0 436 241 Rp 2 15.1
Unilift AP50.50.11.A.1.V 1 x 230 1.6 1.1 8.0 0.92 4.0 436 241 Rp 2 15.1
Unilift AP50.50.11.3.V 3 x 230 1.6 1.2 6.0 0.85 2.8 436 241 Rp 2 15.6
Unilift AP50.50.11.A.3.V 3 x 230 1.6 1.2 6.0 0.85 2.8 436 241 Rp 2 17.9
Unilift AP50.50.11.3.V 3 x 400 1.9 1.2 3.0 0.88 4.9 436 241 Rp 2 15.6
Unilift AP50.50.11.A.3.V 3 x 400 1.9 1.2 3.0 0.88 4.9 436 241 Rp 2 17.9

40
Unilift CC, KP, AP and KP Basic
3
Unilift AP50 installations

Technical data and performance curves


Min.600
600

Start
start
min.

Stop
stop
TM03 1897 3305

TM03 1898 3305


min. ∅800
Min. ø800
min.
Min.ø550
∅550

Fig. 40 One-pump installation with float switch Fig. 41 Two-pump installation with four float switches

Adjustment of cable length for float Two-pump installation


switch The Unilift AP pumps can be used for parallel
The difference in level between start and stop can be installation together with a controlller.
adjusted by changing the free cable length between The example shows an installation with four float
the float switch and the pump handle. switches. The pumps are controlled by the liquid level
• Increasing the free cable length results in fewer in the tank.
starts/stops and a large difference in level. When the liquid lifts up the second float switch from the
• Reducing the free cable length results in more bottom, the first pump will start.
starts/stops and a small difference in level. If the liquid rises faster than one pump can manage,
In order for the float switch to start and stop the pump, the third float switch from the bottom will be lifted up
the free cable length must be min. 100 mm and max. and start the second pump.
350 mm. When the bottom float switch is no longer lifted up by
the liquid, the settable stop delay will set in and after
Cable length Cable length
min. 100 mm max. 350 mm
that both pumps will be stopped.
Pump type When the top float switch is lifted up by the liquid, the
Start Stop Start Stop
[mm] [mm] [mm] [mm] high-level alarm will be activated.
Unilift AP50 500 300 550 100

41
3 Unilift CC, KP, AP and KP Basic

Unilift AP50B Pump housing


Technical data and performance curves

Pump housing with an outstanding design for


submersible wastewater pumps resulting in a high
head.
The pump housing is made of a steel tube with a
smooth surface and a hydraulically correct shape
ensuring free passage of particles.
Ring stand, pump inlet and pump housing are fastened
to the motor by means of four springs enabling quick
and easy dismantling.

Discharge port

TM03 8260 0907


All Unilift AP50B pumps have a threaded R 2
horizontal discharge port.

Shaft and bearings


Fig. 42 Unilift AP50B
The stainless steel shaft rotates in maintenance-free
The Unilift AP50B pump is a single-stage submersible prelubricated ball bearings.
pump designed for pumping effluent.
The pump is suitable for these applications: Impeller
• groundwater lowering The stainless steel impeller is a vortex impeller with
• pumping in drainage collecting wells L-shaped blades and a clearance of 50 mm in the
pump housing. The blades are curved backwards to
• pumping in surface water collecting wells with inflow
reduce any harmful effect from solid particles and to
from roof gutters, shafts, tunnels, etc.
minimise power consumption. The impeller has a
• emptying of ponds, tanks, etc. protective cap to prevent the deposit of long-fibred
• pumping of fibre-containing effluent from laundries material.
and industries
• pumping of domestic effluent from septic tanks and
sludge treating systems
• pumping of domestic effluent without discharge from

TM00 5477 0895


water closets.
Liquid temperature range: 0 °C to +40 °C.

Automatic operation
The pump is available for automatic as well as manual Fig. 43 Impeller, Unilift AP50B
operation and can be installed in a permanent
installation or used as a portable pump. The pump is
Shaft seal
available in these versions: The shaft seal is a combination of a mechanical,
• with float switch fitted for automatic on/off operation bellows shaft seal and a lip seal with 80 ml oil
between two liquid levels (single-phase pumps) between. Seal faces are made of silicone carbide.
• without level switch for manual on/off operation.
Pumps fitted with float switches can also be used for
manual on/off operation. In this case, the float switch
must be secured in an upward-pointing position.

42
Unilift CC, KP, AP and KP Basic
3
Motor

Technical data and performance curves


The motor is a single- or three-phase asynchronous
dry-rotor motor.
Enclosure class: IP68
Insulation class: F (155 °C)
Cable type: H07RN-F.
Single-phase motors have built-in thermal protection.

Materials
Component Materials DIN W. - Nr. AISI
Pump housing Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Washer Stainless steel 1.4301 304
Protective cap Novolen 2360 Kx
Parts in contact
Motor unit complete with liquid: 1.4401 316
Stainless steel
Pump shaft Stainless steel 1.4301 304
Motor cable Neoprene
O-rings NBR rubber
Spring Stainless steel 1.4310
Pump inlet Stainless steel 1.4301 304
Ring stand Polycarbonate
Oil Shell Ondina 15, non-toxic

43
3 Unilift CC, KP, AP and KP Basic

Selection • use steel pipes


Technical data and performance curves

The overview below is suitable for the selection of the • the minimum flow velocity through the vertical
correct size of Unilift AP50B pumps used in stationary discharge pipe (2") must be 1 m/s
applications. • the minimum flow velocity through the horizontal
To ensure that the discharge pipe is self-cleaning, the discharge pipe (2 1/2") must be 0.7 m/s.
calculation of the pipe lengths is based on these
requirements:

TM03 1882 3305


The overview is only intended as a guide. Grundfos is
not liable for installations not complying with the
overview.
The vertical height of the discharge pipe should be
measured from the pump stop level.

44
Unilift CC, KP, AP and KP Basic
3
Performance curves Dimensional sketch

Technical data and performance curves


p H
[kPa] [m]
200
AP50B
20
50 Hz
ISO 9906 Annex A
18

160
16

14

120 12

10

A
AP

80 8 AP
50
B AP
50
B.5
0 .15
.3
S
.50 50
AP .08 B.5
50 .3 0.1
B .50 AP 1.3
6 .08 50
.1 B.5
0.1
1.1
40 4

TM03 4097 1806


2

C
0 0

D
0 4 8 12 16 20 24 28 32 Q [m³/h]

0 2 4 6 8 10 Q [l/s]

P1 P1
[hp] [kW]
2.4
Fig. 44 Pump dimensions
AP50B.50.15.3
3
2.0
.11.1
AP50B.50
1.6
2 AP50B.50.11.3
TM01 3582 0803

1.2 0.08.3
AP50B.5
1
AP50B.50.08.
1 0.8

0.4

0 0.0
0 4 8 12 16 20 24 28 32 Q [m³/h]

I start Dimensions [mm]


Voltage P1 P2 In C --------- Weight
Pump type Cos φ In Cable length and plug
[V] [kW] [kW] [A] [μF] A C D S [kg]

Unilift AP50B.50.08.A1.V 1 x 230 1.2 0.7 5.37 0.97 16 18.4 468 116 73 R 2 10.1 5 m with Schuko plug
Unilift AP50B.50.08.1.V 1 x 230 1.2 0.7 5.37 0.97 16 18.4 468 116 73 R 2 10.1 10 m with Schuko plug
Unilift AP50B.50.08.3.V 3 x 400 1.25 0.8 1.95 0.89 10.6 468 116 73 R 2 8.4 5 m without plug
Unilift AP50B.50.11.A1.V 1 x 230 1.75 1.2 8.00 0.95 16 23.8 468 116 73 R 2 10.2 5 m with Schuko plug
Unilift AP50B.50.11.1.V 1 x 230 1.75 1.2 8.00 0.95 16 23.8 468 116 73 R 2 10.2 10 m with Schuko plug
Unilift AP50B.50.11.3.V 3 x 400 1.75 1.3 2.81 0.90 16.0 468 116 73 R 2 9.7 5 m without plug
Unilift AP50B.50.15.3.V 3 x 400 2.15 1.5 3.00 0.88 22.4 468 116 73 R 2 10.0 5 m without plug

Start/stop level
600
Min.600

Start
start
min.

Stop
stop
TM03 1914 3305

∅550
Min. ø550
min.

Fig. 45 Minimum well dimensions, Unilift AP50B

Start Stop
Pump type
[mm] [mm]
Unilift AP50B 633 270

45
3 Unilift CC, KP, AP and KP Basic

Unilift AP50B installations


Technical data and performance curves

A B

C D
F







• •
• •
• •
J

• • • •



• • •
• • •
Z

• • • •
• • •
• • •
• • •

• •
• • • • •
• • • •


• • • • • • • • • •• •
• •
• • • • •
• • • • • • •
• • • •
• •
U

• • • • •

• •
• • • • • • • •
• • • • •
• • • • • • • • • •
• • • • • •
• • • • •• •
• • • •
• • • • • • • • • • • •
• •
• • • • • • • • • •
• • • •
• • • • • • • •
• • • • •
• • • • • • • • • • • • •
• • •
• •
• • • • • • • • •
• • •
• • • •
• • • •
• • • • • • •
• •
• • •

G I
TM03 4194 1806

TM01 3592 0299


K L M M
N O P R P

Fig. 46 Dimensional sketch, one-pump installation on Fig. 47 Dimensional sketch, two-pump installation on
auto-coupling system auto-coupling system

One-pump installation on auto coupling


Dimensions [mm]
Pump type
A B C D E F G I J K L M N O P R S T U Z
Unilift AP50B.50.08 600 600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 3/4" 130 261
Unilift AP50B.50.11 600 600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 3/4" 130 261
Unilift AP50B.50.15 600 600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 3/4" 130 261

Two-pump installation on auto coupling


Dimensions [mm]
Pump type
A B C D E F G I J K L M N O P R S T U Z
Unilift AP50B.50.08 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 3/4" 130 261
Unilift AP50B.50.11 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 3/4" 130 261
Unilift AP50B.50.15 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 3/4" 130 261

46
Unilift CC, KP, AP and KP Basic
4

4. Controllers

Controllers
Control box Level controller
Variants A level controller and switches are available as
accessories for the control, monitoring and protection
The Unilift AP pump range comprises versions with or
of three-phase 50 Hz Unilift AP pumps.
without control box and float switch, designed for
single-phase or three-phase power supply. The level controller incorporates motor starter,
contactors and light-emitting diodes (LC/LCD) for
All types are designed for voltage tolerances of
indication of operating conditions.
- 10 %/+ 10 %.
Grundfos offers three types of level controller:
Pumps with control box and float switch LC, LCD 107, LC, LCD 108 and LC, LCD 110.
Some Unilift AP pumps are available with float switch The three level controllers are described in the
for automatic start/stop of the pump. The float switch following pages.
cable should be fastened to the pump handle.
The difference in level between start and stop can be
adjusted by changing the free cable length between
the float switch and the pump handle.
Large difference in level: Long cable.
Small difference in level: Short cable.
The float switch is connected direct to the control box
by a 10-metre cable.
The mains cable between the pump and the control
box is 10 metres. The mains cable of the control box is
a 0.8-metre free cable end.
The control box includes a motor starter. The pumps

TM03 1899 3305


require no further motor protection.
In case of a too high level, an alarm signal can be
given by a separate float switch connected to an alarm.
High-level alarm switch and alarm are available as
accessories.
Fig. 48 Unilift AP35/50 pump with control box and float
For further details, see "Product range" on page 57. switch
Pumps with control box without float switch for
manual on/off operation
The mains cable between the pump and the control
box is 10 metres. The mains cable of the control box is
an 0.8 metres long free cable end.
The control box includes a motor starter and a run
capacitor but no relays for float switch.
Pumps without control box
Pumps without control box must be connected to a
separate motor starter, available as an accessory.
Single-phase pumps must also be connected to a
capacitor.
TM03 1900 3305

Fig. 49 Unilift AP35/50 pump with control box without float


switch for manual on/off operation

47
4 Unilift CC, KP, AP and KP Basic

The LC 107 and LCD 107 enable the following:


Controllers

• control of one or two pumps based on signals from


bell-shaped level pickups
• automatic pump changeover (even distribution of
operating hours on both pumps)
• selection of automatic test run every 24 hours
during long periods of inactivity to prevent the shaft
from seizing up
• protection against water hammer as quick restart/
simultaneous start is blocked and delayed
• battery back-up in case of mains supply failure
(accessory!)
• starting delay within the range from 0 to
255 seconds (random) after returning from battery

TM03 1901 3305


operation to mains operation (resulting in an even
mains load when several pumping stations are
started up at the same time)
• selection of automatic alarm resetting
Fig. 50 Unilift AP35B/AP50B pumps with LCD level
controller • selection of automatic restarting
• setting of stop delays matching the actual operating
conditions
LC 107, LCD 107 • indication of liquid level
The LC 107 and LCD 107 pump controllers are • alarm indication of:
designed for level control, monitoring and protection of
– too high liquid level which triggers a high-level
Grundfos Unilift AP pumping systems up to 23 A/11 kW
alarm
(P1) per pump starting direct-on-line.
– overload (via motor protection relay)
• LC 107 is a one-pump controller
– overtemperature (via PTC resistance/thermal
• LCD 107 is a two-pump controller.
switch in motor)
LC 107 and LCD 107 are supplied as complete
– wrong phase sequence
controllers incorporating motor protection relay, bell-
shaped level pickups, pneumatic tubes and control – mains supply failure
unit. – failing level pickup.
Control is based on pneumatic signals which the As standard, the LC 107 and LCD 107 have two alarm
LC 107 and LCD 107 receive via pneumatic tubes from signal outputs:
two or three level pickups positioned in a collecting • common alarm
tank. • high-level alarm.

48
Unilift CC, KP, AP and KP Basic
4
Technical data

Controllers
LC 107
Voltage tolerances
- 15 %/+ 10 % of rated voltage.
Mains frequency
50/60 Hz.
Ambient temperature
• During operation: -30 °C to +50 °C
(must not be exposed to direct sunlight).
• In storage: -30 °C to +60 °C.
Enclosure class
Pump
IP55.
Pneumatic tubes
• Maximum 20 m per tube
(standard: pneumatic tube of 10 m).
• Diameter: 10 mm.
High-level alarm
TM01 4921 1199 • Material: PA 11.
Settable Start of pump
Outputs for alarm devices
stop delay Stop of pump
Max. 230 VAC / max. 2 A / min. 10 mA / AC 1.

Fig. 51 Installation with LC 107 and two level pickups


Dimensions
m
150 m
LCD 107
410 mm

TM01 4946 1199


27 8 mm

Pumps
Fig. 53 Dimensional sketch, control cabinet

High-level alarm
TM01 4922 1199

Start of second pump


Settable Start of pump
stop delay Stop of pump

Fig. 52 Installation with LCD 107 and three level pickups

49
4 Unilift CC, KP, AP and KP Basic

LC 108, LCD 108 Technical data


Controllers

The LC 108 and LCD 108 pump controllers are Voltage tolerances
designed for level control, monitoring and protection of - 15 %/+ 10 % of rated voltage.
Grundfos Unilift AP pumps in wastewater, water supply
and drainage systems. Mains frequency
Up to 23 A/11 kW (P1) starting direct-on-line (DOL). 50/60 Hz.
Up to 72 A/30 kW (P1) starting star-delta (Y/D). Ambient temperature
• LC 108 is a one-pump controller • During operation: -30 °C to +50 °C
• LCD 108 is a two-pump controller. (must not be exposed to direct sunlight).
The LC 108 and LCD 108 are supplied as complete • In stock: -30 °C to +60 °C.
controllers incorporating motor protection relay and
Enclosure class
control unit.
The LC 108 and LCD 108 enable the following: IP55.
• control of one or two pumps based on signals from Outputs for alarm devices
float switches, electrodes or flow switches Max. 230 VAC / max. 2 A / min. 10 mA / AC 1.
• selection of automatic test run (every 24 hours)
Supply system earthing
during long periods of inactivity to prevent the shaft
from seizing up For TN systems and TT systems.
• protection against water hammer as quick restart is Rated insulation voltage, Ui
blocked and delayed (5 seconds 4 kV.
• selection of automatic alarm resetting
Rated impulse withstand voltage, Uimp
• selection of automatic restarting (after
overtemperature) 4 kV.
• setting of stop delays matching the actual operating EMC (electromagnetic compatibility)
conditions According to EN 50 081-1 and EN 50 082-2.
• indication of liquid level
• alarm indication of: Dimensions
– wrong phase sequence
B
– inadmissibly high liquid level
– overload (via motor protection relay)
– overtemperature (via PTC resistance or thermal
switch in motor)
– defective float switch, electrode or flow switch
H

– mains supply failure (by installing a battery back-


up, available as an accessory).
• automatic pump changeover (even distribution of

TM01 9007 0900


operating hours on both pumps) (LCD 108 only).
As standard, the LC 108 and LCD 108 controllers
L
incorporate a buzzer for alarm indication.
Furthermore, the controller has one alarm output for
common alarm. Fig. 54 Dimensional sketch, control cabinet

Applications Type
Dimensions [mm]

The LC 108 and LCD 108 can be connected and set to H L B


operation/control in seven different ways: LC 108, direct-on-line
410 278 150
LCD 108, direct-on-line
• systems with two float switches LC 108, star-delta 628 445 180
• systems with three float switches
• systems with four float switches
• systems with two electrodes
• systems with three electrodes
• systems for filling applications
• systems for drainage applications.

50
Unilift CC, KP, AP and KP Basic
4
Float switches LC 110, LCD 110

Controllers
The Unilift AP pumps in combination with LC 108 or The LC 110 and LCD 110 pump controllers are
LCD 108 are available with float switches for automatic designed for level control, monitoring and protection of
level control. Float switches supplied by Grundfos are Grundfos Unilift AP pumps in wastewater, water supply
of the non-mercury type. and drainage systems up to 23 A/11 kW (P1) starting
LC 108 can be fitted with up to three float switches: direct-on-line (DOL).
• Min. : Stops the pump. The LC 110 and LCD 110 are supplied as complete
• Max. : Starts the pump. controllers incorporating motor protection relay and
• Alarm: Alarm (optional): control unit.
high-water level or pump fault. The LC 110 and LCD 110 enable the following:
LCD 108 can be fitted with up to four float switches: • control of one or two pumps based on signals from
• Min. : Stops the pump. electrodes
• Max. 1: Starts the pump. • selection of automatic test run (every 24 hours)
• Max. 2: Starts the other pump. during long periods of inactivity to prevent the shaft
• Alarm: Alarm (optional): from seizing up
high-water level or pump fault. • starting delay within the range from 0 to
The float switches are to be installed in the collecting 255 seconds (random) after returning from battery
tank floating on the pumped liquid. operation to mains operation (resulting in an even
mains load when several pumping stations are
The position of the float switches decides when the
started up at the same time)
LC 108 or LCD 108 starts and stops the Unilift AP
pumps: • protection against water hammer as quick restart is
blocked and delayed (5 seconds)
• When the float switch is pointing upwards, the float
switch contact will be closed and the pump will start. • selection of automatic alarm resetting
• When the float switch is pointing downwards, the • selection of automatic restarting (after
float switch contact will be opened and the pump will overtemperature)
stop. • setting of stop delays matching the actual operating
conditions
• indication of liquid level
• alarm indication of:
– wrong phase sequence
TM00 6678 4695

ON – high liquid level


OFF – overload (via motor protection relay)
– overtemperature (via thermal switch in motor)
Fig. 55 Principle sketch of float switch contact – dry running
– mains supply failure (when battery back-up is
fitted as an accessory).
As standard, the LC 110 and LCD 110 controllers
incorporate a buzzer for indication of alarm.
Furthermore, the controller has one alarm output for
common alarm.

51
4 Unilift CC, KP, AP and KP Basic

Applications Technical data


Controllers

The LC 110 and LCD 110 can be connected and set to Voltage tolerances
operation/control in six different ways:
- 15 %/+ 10 % of rated voltage.
• systems with three electrodes (LC 110):
Electrode for reference, start/stop and high-level Mains frequency
alarm 50/60 Hz.
• systems with four electrodes (LC 110): Ambient temperature
Electrode for reference, stop, start and high-level
• During operation: -30 °C to +50 °C
alarm
(must not be exposed to direct sunlight).
• systems with five electrodes (LC 110):
• In stock: -30 °C to +60 °C.
Electrode for reference, dry-running alarm, stop,
start and high-level alarm Enclosure class
• systems with four electrodes (LCD 110): IP55.
Electrode for reference, start of pump 1/common
Outputs for alarm devices
stop, start of pump 2 and high-level alarm
• systems with five electrodes, parallel operation Max. 230 VAC / max. 2 A / min. 10 mA / AC 1.
(LCD 110): Supply system earthing
Electrode for reference, common stop, start of pump For TN systems and TT systems.
1, start of pump 2 and high-level alarm
• systems with five electrodes, 100 % standby Rated insulation voltage, Ui
(LCD 110): 4 kV.
Electrode for reference, common stop, start of pump Rated impulse withstand voltage, Uimp
1, high-level alarm and start of pump 2
4 kV.
• systems with five electrodes, full control (LCD 110):
Electrode for reference, stop of pump 1, stop of EMC (electromagnetic compatibility)
pump2, start of pump 1 and start of pump 2. According to EN 50 081-1 and EN 50 082-2.

Dimensions
m
150 m
410 mm

TM01 8152 5099


27 8 mm

Fig. 56 Dimensional sketch, control cabinet

52
Unilift CC, KP, AP and KP Basic
5

5. Accessories

Accessories
Accessories for Unilift CC, KP, AP pumps
Pump type
Product
Pos. Accessories Unilift
number
CC KP AP12.40 AP12.50 AP35 AP35B AP50 AP50B
Rp 1 1/2 / 2 ● ● 96023831
1 Bushing for pipe connection (PVC)
Rp 2 / 2 1/2 ● ● 96023832
Rp 1 1/2 / 1 1/2 ● ● 96003997
Rp 1 1/2 / 2 ● ● 96023834
2 Hose nipple (PVC)
Rp 2 / 2 ● ● ● ● 96023835
Rp 2 / 2 1/2 ● ● ● 96023836
1 1/2" ● ● 96023837
3 10 m rubber hose incl. clamps (PVC) 2" ● ● ● ● ● ● 96023838
2 1/2" ● ● ● 96023839
Rp 1 1/2 ● ● 96023840
4 Connecting piece for rubber hoses (PVC) Rp 2 ● ● ● ● ● ● 96023841
Rp 2 1/2 ● ● ● 96023842
Rp 1 1/2 ● ● 96023843
Non-return valve (PVC)
5 Rp 2 ● ● ● ● ● ● 96023844
ball type
Rp 2 1/2 ● ● ● 96002003
Rp 1 1/2 ● ● 96023846
6 Isolating valve (PVC) Rp 2 ● ● ● ● ● ● 96023847
Rp 2 1/2 ● ● ● 96023848
Rp 1 1/2 ● ● 96023849
7 Hexagon nipple (PVC) Rp 2 ● ● ● ● ● ● 96023850
Rp 2 1/2 ● ● ● 96023851
Rp 1 1/2 ● ● 96023852
8 Union (PVC) Rp 2 ● ● ● ● ● ● 96023853
Rp 2 1/2 ● ● ● 96023854
Rp 1 1/2 ● ● 96023855
9 90 ° pipe bend (PVC) Rp 2 ● ● ● ● ● ● 96023856
Rp 2 1/2 ● ● ● 96023857
Non-return valve for location in the pump Rp 1 1/4 ● ● 00015220
10
discharge (stainless steel) Rp 1 1/2 ● ● 96003855
Auto coupling Rp 2/Rp 2 ● ● 96429519
G 1 1/4 x 25 ● 00ID3588
Hose couplings
G 1 1/4 x 32 ● 00ID3589
Screwed couplings (polyamide)
G 1 1/4 x 40 ● 00ID3590
 Cast iron

7
3
6
4
7
3
5 10
2
7

1
TM00 5924 1895

TM00 5925 1895

TM01 8708 0700

Fig. 57 Unilift with hose connection Fig. 58 Unilift with pipe connection, Fig. 59 Functional sketch of
isolating valve and non-return valve in Unilift
non-return valve pump discharge

53
5 Unilift CC, KP, AP and KP Basic

Level controllers and accessories


Accessories

including hour counter

including start counter

hour and start counter


operating instructions
Mains switch required
Operating current per

Grundfos product no.

Grundfos product no.

Grundfos product no.

Grundfos product no.


including combined
installation and
Description

Language of
pump [A]

[A]
LC 107 level controller for one pump1 x 1.0 - 5.0 16 GB/DK/D/F/NL 96841806
230 V, direct-on-line starting 3.2 - 12.0 16 GB/DK/D/F/NL 96841807
1 - 5.0 16 GB/DK/D/F/NL 96841832
LC 107 level controller for one pump3 x
3.2 - 12.0 16 GB/DK/D/F/NL 96841834
400 V, direct-on-line starting
6.0 - 23.0 35 GB/DK/D/F/NL 96841835
LCD 107 level controller for two pumps1 x 1.0 - 5.0 16 GB/DK/D/F/NL 96841836
230 V, direct-on-line starting 3.2 - 12.0 25 GB/DK/D/F/NL 96841837
1 - 5.0 16 GB/DK/D/F/NL 96841841
LCD 107 level controller for two pumps3 x
3.2 - 12.0 25 GB/DK/D/F/NL 96841842
400 V, direct-on-line starting
6.0 - 23.0 50 GB/DK/D/F/NL 96841843
GB/D/PL/NL 96841844 96841845 96841846
1.0 - 5.0 16 GB/GR/I/F/E 96841873 96841874 96841875
GB/DK/S/RU 96841902 96841903 96841904
GB/D/PL/NL 96841847 96841848 96841849 96841850
LC 108 level controller for one pump1 x
3.2 - 12.0 16 GB/GR/I/F/E 96841876 96841877 96841878 96841879
230 V, direct-on-line starting
GB/DK/S/RU 96841905 96841906 96841907 96841908
GB/D/PL/NL 96841854
6.0 - 23.0 35 GB/GR/I/F/E 96841883
GB/DK/S/RU 96841912
GB/D/PL/NL 96841855
1 - 5.0 16 GB/GR/I/F/E 96841884
GB/DK/S/RU 96841913
GB/D/PL/NL 96841856 96841857
LC 108 level controller for one pump 3 x
3.2 - 12.0 16 GB/GR/I/F/E 96841885 96841886
230 V, direct-on-line starting
GB/DK/S/RU 96841914 96841915
GB/D/PL/NL 96841858
6.0 - 23.0 16 GB/GR/I/F/E 96841887
GB/DK/S/RU 96841916
GB/D/PL/NL 96841859 96841860 96841861
1.0 - 5.0 16 GB/GR/I/F/E 96841888 96841889 96841890
GB/DK/S/RU 96841917 96841918 96841919
GB/D/PL/NL 96841863 96841865 96841864 96841866
LC 108 level controller for one pump 3 x
3.2 - 12.0 16 GB/GR/I/F/E 96841892 96841894 96841893 96841895
400 V, direct-on-line starting
GB/DK/S/RU 96841921 96841923 96841922 96841924
GB/D/PL/NL 96841867 96841868
6.0 - 23.0 25 GB/GR/I/F/E 96841896 96841897
GB/DK/S/RU 96841925 96841926
GB/D/PL/NL 96841869
5.5 - 20.0 35 GB/GR/I/F/E 96841898
GB/DK/S/RU 96841927
GB/D/PL/NL 96841870
10.0 - 30.0 63 GB/GR/I/F/E 96841899
LC 108 level controller for one pump 3 x GB/DK/S/RU 96841928
400 V, star-delta starting GB/D/PL/NL 96841871
15.5 - 59.0 125 GB/GR/I/F/E 96841900
GB/DK/S/RU 96841929
GB/D/PL/NL 96841872
15.5 - 72.0 160 GB/GR/I/F/E 96841901
GB/DK/S/RU 96841930
GB/D/PL/NL 96841935 96841936 96841937
1 - 5.0 16 GB/GR/I/F/E 96841962 96841963 96841964
GB/DK/S/RU 96841989 96841990 96841991
GB/D/PL/NL 96841938 96841939
LCD 108 level controller for two pumps 3 x
3.2 - 12.0 25 GB/GR/I/F/E 96841965 96841966
230 V, direct-on-line starting
GB/DK/S/RU 96841992 96841993
GB/D/PL/NL 96841940 96841941
6.0 - 23.0 50 GB/GR/I/F/E 96841967 96841968
GB/DK/S/RU 96841994 96841995

54
Unilift CC, KP, AP and KP Basic
5

Accessories
including hour counter

including start counter

hour and start counter


operating instructions
Mains switch required
Operating current per

Grundfos product no.

Grundfos product no.

Grundfos product no.

Grundfos product no.


including combined
installation and
Description

Language of
pump [A]

[A]
GB/D/PL/NL 96841942 96841943 96841944 96841945
1 - 5.0 25 GB/GR/I/F/E 96841969 96841970 96841971 96841972
GB/DK/S/RU 96841996 96841997 96841998 96841999
GB/D/PL/NL 96841948 96841949 96841950
LCD 108 level controller for two pumps 3 x
3.2 - 12.0 40 GB/GR/I/F/E 96841975 96841976 96841977
400 V, direct-on-line starting
GB/DK/S/RU 96842002 96842003 96842004
GB/D/PL/NL 96841951 96841952 96841953
6.0 - 23.0 60 GB/GR/I/F/E 96841978 96841979 96841980
GB/DK/S/RU 96842005 96842006 96842007
GB/D/PL/NL 96841954
5.5 - 20.0 50 GB/GR/I/F/E 96841981
GB/DK/S/RU 96842008
GB/D/PL/NL 96841955
10.0 - 30.0 63 GB/GR/I/F/E 96841982
LCD 108 level controller for two pumps 3 x GB/DK/S/RU 96842009
400 V, star-delta starting GB/D/PL/NL 96841956
15.5 - 59.0 125 GB/GR/I/F/E 96841983
GB/DK/S/RU 96842010
GB/D/PL/NL 96841957
15.5 - 72.0 160 GB/GR/I/F/E 96841984
GB/DK/S/RU 96842011
1 - 5.0 16 GB/DK/D 96842054
LC 110 level controller for one pump 1 x
3.2 - 12.0 16 GB/DK/D 96842056
230 V, direct-on-line
6.0 - 23.0 25 GB/DK/D 96842060
1 - 5.0 16 GB/DK/D 96842061
LC 110 level controller for one pump 3 x
3.2 - 12.0 16 GB/DK/D 96842064
400 V, direct-on-line
6.0 - 23.0 25 GB/DK/D 96842066
LCD 110 level controller for two pumps 1 x 1 - 5.0 16 GB/DK/D 96842067
230 V, direct-on-line 3.2 - 12.0 25 GB/DK/D 96842069
1 - 5.0 16 GB/DK/D 96842080
LCD 110 level controller for two pumps 3 x
3.2 - 12.0 25 GB/DK/D 96842087
400 V, direct-on-line
6.0 - 23.0 50 GB/DK/D 96842094

55
5 Unilift CC, KP, AP and KP Basic

Accessories for controllers


Accessories

Description Product no.


Battery back-up 96002520
Flashing light for external alarm indication 62500020
Alarm horn for external alarm indication (outdoor
62500021
installation)
Alarm horn for external alarm indication (indoor
62500022
installation)
Hour counter [230 V] 96002514
Hour counter [400 V] 96002515
Start counter [230 V] 96002516
Start counter [400 V] 96002517
Combined hour and start counter [230 V] 96002518
Combined hour and start counter [400 V] 96002519
25 [A] external mains switch for supply cable 96002511
40 [A] external mains switch for supply cable 96002512
80 [A] external mains switch for supply cable 96002513
Bracket for electrodes 91713196
Three electrodes with 10 m cable 96076489
Four electrodes with 10 m cable 91713437

SMS module
The LC, LCD controllers can be equipped with an SMS
module. An SMS module integrated in an LC, LCD
controller acts as a time recorder for the pumps.
When it has been programmed (using an ordinary
mobile phone with text messaging facility), it can send
text messages containing "high-water alarm", "general
alarm", information about operating hours and the
number of starts.
The SMS module is available with battery enabling it to
send text messages that will inform you of power
failure and when power has been restored.
The LC, LCD controller functions independently - both
before and after integration of the SMS module.
The SMS module is primarily intended as a monitoring
unit or alarm transmitter. Thus, the operator will
receive a text message in the event of an emergency
mode in the system and will be able to retrieve
operating information.

Description Product no.


SMS module (GB*) 96805159
SMS module (DK*) 96805158
SMS module (D*) 96805160
SMS module (F*) 96805161
SMS module (ES*) 96805172
SMS module (RU*) 96805173
Antenna for SMS module 96805155
Battery for SMS module 96805157
SMS module kit complete (GB*) 96805179
SMS module kit complete (DK*) 96805177
SMS module kit complete (D*) 96805182
SMS module kit complete (F*) 96805183
SMS module kit complete (ES*) 96805184
SMS module kit complete (RU*) 96805185

* Language of text messages and installation and operating


instructions.

56
Unilift CC, KP, AP and KP Basic
6

6. Product range

Product range
Unilift CC
1 x 220-240 V

Plug type Float switch Cable type


Net
Pump type Product number Without weight
Without With float
Schuko Australia float H05RN-F 3G0.75 H07RN-F 3G1 [kg]
plug switch
switch
96280965 ● ● ●
96280966 ● ● ●
96280971 ● ● ●
Unilift CC 5 4.35
96280972 ● ● ●
96280977 ● ● ●
96280978 ● ● ●
96280967 ● ● ●
96280968 ● ● ●
96280973 ● ● ●
Unilift CC 7 4.6
96280974 ● ● ●
96280979 ● ● ●
96280980 ● ● ●
96280969 ● ● ●
96280970 ● ● ●
96280975 ● ● ●
Unilift CC 9 6.5
96280976 ● ● ●
96280981 ● ● ●
96280982 ● ● ●

Special versions
Plug type Float switch Cable type
Wetted Net
Product Without
Pump type parts With float 4m 10 m weight
number Schuko float H05RN-F 3G0.75 H07RN-F 3G1
EN 1.4401 switch cable cable [kg]
switch
Unilift CC 5 98624419 ● ● ● ● 4.37
98624463 ● ● ● ●
Unilift CC 7 5.15
98624464 ● ● ● ● ●
98624465 ● ● ● ●
Unilift CC 9 4.55
98624466 ● ● ● ● ●

57
6 Unilift CC, KP, AP and KP Basic

Unilift KP 150
Product range

1 x 220-230 V

Vertical level
Pump type Float switch 5 m cable 10 m cable With plug Plug type Product no.
switch
KP 150 ● Schuko 011H1300
KP 150 ● ● ● Schuko 011H1600
KP 150 ● ● ● Schuko 011H1400
KP 150 ● ● ● Schuko 011H1800
KP 150 ● ● ● Schuko 011H1900
KP 150 ● ● Denmark 011H2300
KP 150 ● ● ● Denmark 011H2600
KP 150 ● ● ● Denmark 011H2400
KP 150 ● ● ● Denmark 011H2800
KP 150 ● ● ● Denmark 011H2900
KP 150 ● ● Switzerland 011H3300
KP 150 ● ● ● Switzerland 011H3600
KP 150 ● ● ● Switzerland 011H3400
KP 150 ● ● ● Switzerland 011H3800
KP 150 ● ● ● Switzerland 011H3900
KP 150 ● ● Italy 011H5300
KP 150 ● ● ● Italy 011H5600
KP 150 ● ● ● Italy 011H5400
KP 150 ● ● Italy 011H5800
KP 150 ● 011H6300
KP 150 ● ● 011H6600
KP 150 ● ● 011H6400
KP 150 ● 011H6800
KP 150 ● ● 011H6900

1 x 230-240 V

Vertical level
Pump type Float switch 5 m cable 10 m cable With plug Plug type Product no.
switch
KP 150 ● ● Australia 011K4100 KP 150
KP 150 ● ● ● Australia 011K4700 KP 150
KP 150 ● ● ● Australia 011K4500 KP 150

58
Unilift CC, KP, AP and KP Basic
6
Unilift KP 250

Product range
1 x 220-230 V

Vertical level
Pump type Float switch 5 m cable 10 m cable With plug Plug type Product no.
switch
KP 250 ● ● Schuko 012H1300
KP 250 ● ● ● Schuko 012H1600
KP 250 ● ● ● Schuko 012H1400
KP 250 ● ● ● Schuko 012H1800
KP 250 ● ● ● Schuko 012H1900
KP 250 ● ● Denmark 012H2300
KP 250 ● ● ● Denmark 012H2600
KP 250 ● ● ● Denmark 012H2400
KP 250 ● ● ● Denmark 012H2800
KP 250 ● ● ● Denmark 012H2900
KP 250 ● ● Switzerland 012H3300
KP 250 ● ● ● Switzerland 012H3600
KP 250 ● ● ● Switzerland 012H3400
KP 250 ● ● ● Switzerland 012H3800
KP 250 ● ● ● Switzerland 012H3900
KP 250 ● ● Italy 012H5300
KP 250 ● ● ● Italy 012H5600
KP 250 ● ● ● Italy 012H5400
KP 250 ● ● ● Italy 012H5800
KP 250 ● 012H6300
KP 250 ● ● 012H6600
KP 250 ● ● 012H6400
KP 250 ● ● 012H6800
KP 250 ● 012H6900

1 x 230-240 V

Vertical level
Pump type Float switch 5 m cable With plug Plug type Product no.
switch
KP 250 ● ● Australia 012K4100
KP 250 ● ● ● Australia 012K4700
KP 250 ● ● ● Australia 012K4500

3 x 380-415 V

Pump type 5 m cable 10 m cable Product no.


Unilift KP 250 ● 012M6100
Unilift KP 250 ● 012M6300
Unilift KP 250 ● 012M9100
Unilift KP 250 ● 012M9300

59
6 Unilift CC, KP, AP and KP Basic

Unilift KP 350
Product range

1 x 220-240 V

Vertical level
Pump type Float switch 5 m cable 10 m cable With plug Plug type Product no.
switch
KP 350 ● ● Schuko 013N1300
KP 350 ● ● ● Schuko 013N1600
KP 350 ● ● ● Schuko 013N1400
KP 350 ● ● ● Schuko 013N1800
KP 350 ● ● ● Schuko 013N1900
KP 350 ● ● Denmark 013N2300
KP 350 ● ● ● Denmark 013N2600
KP 350 ● ● ● Denmark 013N2400
KP 350 ● ● ● Denmark 013N2800
KP 350 ● ● ● Denmark 013N2900
KP 350 ● ● Switzerland 013N3300
KP 350 ● ● ● Switzerland 013N3400
KP 350 ● ● ● Switzerland 013N3600
KP 350 ● ● ● Switzerland 013N3800
KP 350 ● ● ● Switzerland 013N3900
KP 350 ● 013N6300
KP 350 ● ● 013N6600
KP 350 ● ● 013N6400
KP 350 ● ● 013N6800
KP 350 ● 013N6900
KP 350 ● ● Australia 013N4100
KP 350 ● ● ● Australia 013N4700
KP 350 ● ● ● Australia 013N4500

3 x 380-415 V

Pump type 5 m cable 10 m cable Product no.


Unilift KP 350 ● 013M6100
Unilift KP 350 ● 013M6300
Unilift KP 350 ● 013M9100
Unilift KP 350 ● 013M9300

60
Unilift CC, KP, AP and KP Basic
6
Unilift AP12

Product range
Voltage Control box with
Pump type Float switch 10 m cable 5 m cable With plug Product no.
[V] 0.8 m supply cable
Unilift AP12.40.04.1 1 x 230 ● ● 96011016
Unilift AP12.40.04.1 1 x 230 ● 96011014
Unilift AP12.40.04.A.1 1 x 230 ● ● ● 96011017
Unilift AP12.40.04.A.1 1 x 230 ● ● 96011015
Unilift AP12.40-04.A.1 1 x 230 ● ● ● 96011018
Unilift AP12.40.04.3 3 x 400 ● 96011024
Unilift AP12.40.04.3 3 x 400 ● ● 96023925
Unilift AP12.40.04.3 3 x 230 ● 96011030
Unilift AP12.40.04.3 3 x 200 ● 96011021
Unilift AP12.40.04.A.3 3 x 400 ● ● ● 96011025
Unilift AP12.40.04.A.3 3 x 400 ● ● ● ● 96023871
Unilift AP12.40.04.A.3 3 x 230 ● ● ● 96011031
Unilift AP12.40.04.A.3 3 x 200 ● ● ● 96011039
Unilift AP12.40.06.1 1 x 230 ● ● 96001720
Unilift AP12.40.06.1 1 x 230 ● 96001732
Unilift AP12.40.06.A.1 1 x 230 ● ● ● 96001735
Unilift AP12.40.06.A.1 1 x 230 ● ● ● 96010979
Unilift AP12.40.06.A.1 1 x 230 ● ● 96001747
Unilift AP12.40.06.3 3 x 400 ● 96001652
Unilift AP12.40.06.3 3 x 230 ● 96010628
Unilift AP12.40.06.3 3 x 200 ● 96010881
Unilift AP12.40.06.A.3 3 x 400 ● ● ● 96010923
Unilift AP12.40.06.A.3 3 x 400 ● ● ● ● 96023872
Unilift AP12.40.06.A.3 3 x 230 ● ● ● 96010957
Unilift AP12.40.06.A.3 3 x 200 ● ● ● 96010922
Unilift AP12.40.08.1 1 x 230 ● 96001873
Unilift AP12.40.08.1 1 x 230 ● ● 96001869
Unilift AP12.40.08.A.1 1 x 230 ● ● ● 96001798
Unilift AP12.40.08.A.1 1 x 230 ● ● ● 96010980
Unilift AP12.04.08.A.1 1 x 230 ● ● 96001867
Unilift AP12.40.08.3 3 x 400 ● 96001791
Unilift AP12.40.08.3 3 x 230 ● 96010630
Unilift AP12.40.08.3 3 x 200 ● 96010882
Unilift AP12.40.08.A.3 3 x 400 ● ● ● 96010925
Unilift AP12.40.08.A.3 3 x 400 ● ● ● ● 96023873
Unilift AP12.40.08.A.3 3 x 230 ● ● ● 96010958
Unilift AP12.40.08.A.3 3 x 200 ● ● ● 96010924
Unilift AP12.50.11.1 1 x 230 ● ● 96001958
Unilift AP12.50.11.1 1 x 230 ● 96001962
Unilift AP12.50.11.A.1 1 x 230 ● ● ● 96001965
Unilift AP12.50.11.A.1 1 x 230 ● ● 96001973
Unilift AP12.50.11.A.1 1 x 230 ● ● ● 96010981
Unilift AP12.50.11.3 3 x 400 ● 96001975
Unilift AP12.50.11.3 3 x 230 ● 96010634
Unilift AP12.50.11.3 3 x 200 ● 96010883
Unilift AP12.50.11.A.3 3 x 400 ● ● ● 96010927
Unilift AP12.50.11.A.3 3 x 400 ● ● ● ● 96023874
Unilift AP12.50.11.A.3 3 x 230 ● ● ● 96010959
Unilift AP12.50.11.A.3 3 x 200 ● ● ● 96010926

61
6 Unilift CC, KP, AP and KP Basic

Unilift AP35
Product range

Control box
Voltage
Pump type with 0.8 m Float switch 10 m cable 5 m cable With plug Product no.
[V]
supply cable
Unilift AP35.40.06.1.V 1 x 230 ● ● 96001796
Unilift AP35.40.06.1.V 1 x 230 ● 96001808
Unilift AP35.40.06.A.1.V 1 x 230 ● ● ● 96001777
Unilift AP35.40.06.A.1.V 1 x 230 ● ● 96001789
Unilift AP35.40.06.A.1.V 1 x 230 ● ● ● 96010982
Unilift AP35.40.06.3.V 3 x 400 ● 96000169
Unilift AP35.40.06.3.V 3 x 230 ● 96010629
Unilift AP35.40.06.3.V 3 x 200 96010884
Unilift AP35.40.06.A.3.V 3 x 400 ● ● ● 96010929
Unilift AP35.40.06.A.3.V 3 x 400 ● ● ● ● 96023875
Unilift AP35.40.06.A.3.V 3 x 230 ● ● ● 96010960
Unilift AP35.40.06.A.3.V 3 x 200 ● ● ● 96010928
Unilift AP35.40.08.1.V 1 x 230 ● ● 96001672
Unilift AP35.40.08.1.V 1 x 230 ● 96001894
Unilift AP35.40.08.A.1.V 1 x 230 ● ● ● 96001897
Unilift AP35.40.08.A.1.V 1 x 230 ● ● 96001905
Unilift AP35.40.08.A.1.V 1 x 230 ● ● ● 96010983
Unilift AP35.40.08.3.V 3 x 400 ● 96001718
Unilift AP35.40.08.3.V 3 x 230 ● 96010631
Unilift AP35.40.08.3.V 3 x 200 ● 96010885
Unilift AP35.40.08.A.3.V 3 x 400 ● ● ● 96010931
Unilift AP35.40.08.A.3.V 3 x 400 ● ● ● ● 96023876
Unilift AP35.40.08.A.3.V 3 x 230 ● ● ● 96010961
Unilift AP35.40.08.A.3.V 3 x 200 ● ● ● 96010930

Unilift AP35B
Voltage
Pump type Float switch 10 m cable 5 m cable With plug Product no.
[V]
Unilift AP35B.50.06.A1.V 1 x 230 ● ● ● 96004562
Unilift AP35B.50.06.1.V 1 x 230 ● ● 96004563
Unilift AP35B.50.06.3.V 3 x 400 ● 96004565
Unilift AP35B.50.08.A1.V 1 x 230 ● ● ● 96004574
Unilift AP35B.50.08.1.V 1 x 230 ● ● 96004575
Unilift AP35B.50.08.3.V 3 x 400 ● 96004577

62
Unilift CC, KP, AP and KP Basic
6
Unilift AP50

Product range
Control box
Voltage
Pump type with 0.8 m Float switch 10 m cable 5 m cable With plug Product no.
[V]
supply cable
Unilift AP50.50.08.1.V 1 x 230 ● ● 96010595
Unilift AP50.50.08.1.V 1 x 230 ● 96010599
Unilift AP50.50.08.A.1.V 1 x 230 ● ● ● 96010584
Unilift AP50.50.08.A.1.V 1 x 230 ● ● ● 96010984
Unilift AP50.50.08.A.1.V 1 x 230 ● ● 96010592
Unilift AP50.50.08.3.V 3 x 400 ● 96010563
Unilift AP50.50.08.3.V 3 x 230 ● 96010632
Unilift AP50.50.08.3.V 3 x 200 ● 96010886
Unilift AP50.50.08.A.3.V 3 x 400 ● ● ● 96010933
Unilift AP50.50.08.A.3.V 3 x 400 ● ● ● ● 96023877
Unilift AP50.50.08.A.3.V 3 x 230 ● ● ● 96010962
Unilift AP50.50.08.A.3.V 3 x 200 ● ● ● 96010932
Unilift AP50.50.11.1.V 1 x 230 ● ● 96010577
Unilift AP50.50.11.1.V 1 x 230 ● 96010581
Unilift AP50.50.11.A.1.V 1 x 230 ● ● ● 96010566
Unilift AP50.50.11.A.1.V 1 x 230 ● ● ● 96010985
Unilift AP50.50.11.A.1.V 1 x 230 ● ● 96010574
Unilift AP50.50.11.3.V 3 x 400 ● 96010562
Unilift AP50.50.11.3.V 3 x 230 ● 96010633
Unilift AP50.50.11.3.V 3 x 200 ● 96010887
Unilift AP50.50.11.A.3.V 3 x 400 ● ● ● 96010935
Unilift AP50.50.11.A.3.V 3 x 400 ● ● ● ● 96023878
Unilift AP50.50.11.A.3.V 3 x 230 ● ● ● 96010963
Unilift AP50.50.11.A.3.V 3 x 200 ● ● ● 96010934

Unilift AP50B
Voltage
Pump type Float switch 10 m cable 5 m cable With plug Product no.
[V]
Unilift AP50B.50.08.A1.V 1 x 230 ● ● ● 96004586
Unilift AP50B.50.08.1.V 1 x 230 ● ● 96004587
Unilift AP50B.50.08.3.V 3 x 400 ● 96004589
Unilift AP50B.50.11.A1.V 1 x 230 ● ● ● 96004598
Unilift AP50B.50.11.1.V 1 x 230 ● ● 96004599
Unilift AP50B.50.11.3.V 3 x 400 ● 96004601
Unilift AP50B.50.15.3.V 3 x 400 ● 96004609

63
6 Unilift CC, KP, AP and KP Basic

KP Basic
Product range

Voltage Plug type Special model Cable type Net


Pump type Product number 1 x 220-240V, weight
Schuko Australia China Indonesia H05RN-F 3G0.75 H07RN-F 3G1 [kg]
50 Hz
96121845 ● ● ●
96121906 ● ● ●
KP Basic 200 96150042 ● ● ● 4.5
96825872 ● ● ●
96827883 ● ● ●
96121846 ● ● ●
96121907 ● ● ●
96150016 ● ● ●
96150043 ● ● ● ●
96825873 ● ● ●
KP Basic 300A 96825876 ● ● ● ● 4.6
96827886 ● ● ● ●
96827889 ● ● ● ●
96827891 ● ● ● ●
96827903 ● ● ● ●
97657635 ● ● ●
96121848 ● ● ●
96121849 ● ● ●
KP Basic 600 96121909 ● ● ● 6.7
96150045 ● ● ● ●
96827888 ● ● ●
96121847 ● ● ●
96121908 ● ● ●
96150017 ● ● ●
96150044 ● ● ● ●
96825874 ● ● ●
KP Basic 600A 7.0
96825877 ● ● ● ●
96827887 ● ● ● ●
96827890 ● ● ● ●
96827902 ● ● ● ●
96827905 ● ● ● ●

64
Unilift CC, KP, AP and KP Basic
7

7. Further product information

Further product information


WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
220,000 Grundfos products in more than 30
languages.
Information in WebCAPS is divided into six sections:
• Catalogue
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.

Catalogue

Based on fields of application and pump types, this section


contains the following:
• technical data
• curves (QH, Eta, P1, P2, etc.) which can be adapted to the
density and viscosity of the pumped liquid and show the
number of pumps in operation
• product photos
• dimensional drawings
• wiring diagrams
• quotation texts, etc.

Literature

This section contains all the latest documents of a given pump,


such as
• data booklets
• installation and operating instructions
• service documentation, such as Service kit catalogue and
Service kit instructions
• quick guides
• product brochures.

Service

This section contains an easy-to-use interactive service


catalogue. Here you can find and identify service parts of both
existing and discontinued Grundfos pumps.
Furthermore, the section contains service videos showing you
how to replace service parts.

65
7 Unilift CC, KP, AP and KP Basic
Further product information

Sizing 0 1

This section is based on different fields of application and


installation examples and gives easy step-by-step instructions in
how to size a product:
• Select the most suitable and efficient pump for your
installation.
• Carry out advanced calculations based on energy,
consumption, payback periods, load profiles, life cycle costs,
etc.
• Analyse your selected pump via the built-in life cycle cost tool.
• Determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing


replacement data of an installed pump in order to replace the
pump with a more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare


Grundfos pumps with the one you have installed on your site.
When you have specified the installed pump, the guide will
suggest a number of Grundfos pumps which can improve both
comfort and efficiency.

CAD drawings

In this section, it is possible to download 2-dimensional (2D) and


3-dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:
• .dxf, wireframe drawings
• .dwg, wireframe drawings.

3-dimensional drawings:
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed
information on more than 220,000 Grundfos products
in more than 30 languages.
The program contains the same features and
functions as WebCAPS, but is an ideal solution if no
internet connection is available.
WinCAPS is available on DVD and updated once a
year.

Fig. 60 WinCAPS DVD

66
Unilift CC, KP, AP and KP Basic
7
GO CAPS

Further product information


Mobile solution for professionals on the GO!

CAPS functionality on the mobile


workplace.

Subject to alterations.

67
ECM: 1132516
96604141 0314

GRUNDFOS A/S

www.grundfos.com
Telephone: +45 87 50 14 00
DK-8850 Bjerringbro . Denmark
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. © Copyright Grundfos Holding A/S

You might also like