ETDDouble Brochure EN 11196

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

ENDOSCOPIC REPROCESSING

ETD DOUBLE
Advancing the Efficiency of Reprocessing.
11157
ETD DOUBLE: INTRODUCING THE FIRST OLYMPUS PASS-
THROUGH WASHER-DISINFECTOR

With the ETD Double, Olympus Has Advanced Its Long Tradition of ETD Machines, Enabling the Strict, Reputable High Quality with a Tradition-Rich Systematic Approach to Your Endoscope
Physical Separation of Clean from Dirty. History Reprocessing
Olympus has broad experience in endoscope The systematic Olympus approach to endoscope
This new concept is designed to: reprocessing that spans more than 25 years. We use reprocessing offers all the solutions you need to cover
■■ Optimize your work flow that expertise to constantly optimize and facilitate the complete work cycle, from one patient to the
■■ Provide you with hygienic results at the highest level endoscope reprocessing in your department. next. From transport to automated reprocessing, from
■■ Ensure the safety of your patients and employees storage to documentation – you can count on a uniform,
■■ Protect sensitive, high-tech endoscope instruments sophisticated concept that gives priority to endoscope
hygiene and patient safety.
11034
ADVANCING WORK FLOW EFFICIENCY

The ETD Double Enhances Your Daily routine for a Faster and Smoother Work Flow with a Range of
Usability Features:

Simultaneous Reprocessing of up to Three Endoscopes


Meeting the requirements of your busy endoscopy unit, the ETD Double is the first Olympus washer-disinfector to
reprocess up to three endoscopes simultaneously.

Loading of Baskets and Connection of Endoscope Channels Is Done Entirely Outside the ETD Double
·· Placement of your endoscopes into the basket and connection of endoscope channels to the ready-to-use
adapter sets is conducted entirely outside the ETD Double
·· This allows you to prepare your endoscopes for automated reprocessing while your ETD Double is running
a cycle
·· Upon cycle completion, the loaded basket can simply be inserted and the next cycle can start
·· No additional manual connections inside the washer-disinfector are required, speeding up your work flow
significantly by decreasing the down time of your ETD Double to a minimum

Easy Placement and Connection of Endoscopes


The universal one-fits-all basket can reprocess any type of compatible endoscope.

Ready-to-use adapter sets for Olympus endoscopes and other compatible endoscope brands allow straightforward
connection of up to seven endoscope channels. The specially developed quick-connect technology allows rapid,
individual connection of all endoscope ports.

This innovative principle significantly simplifies the connection of endoscope channels.


11153

11154

Loading of baskets and connection of endoscope channels fully outside Easy connection of endoscopes.
the ETD Double.
11152
ADVANCING SAFETY

The highest level of safety for your patients, users, and endoscopes is our primary focus. The ETD Double comes Ergonomic Machine Loading Independent Monitoring of Process-Critical
equipped with additional, sophisticated safety and monitoring benefits for your endoscope reprocessing. These The ETD Double washing chamber is positioned at Parameters
include: a comfortable, accessible height for users, while the The ETD Double’s innovative independent monitoring
·· Advanced leakage test technology ·· A sophisticated, independent monitoring system Olympus ETD Double loading trolley allows for height- system enables supervision of process-critical
·· Enhanced RFID-based tracing technology ·· Color- and mechanically coded adapter sets adjustable placement of endoscope baskets. parameters, such as temperatures and dosage volumes,
completely isolated from the main control system. This
Color- and Mechanically Coded Adaptation Principle Real-Value Documentation two-sensor system leads to excellent standards of safety
Every single adapter is color-coded to facilitate a With the ETD Double, you can document the real values for your patients and your endoscopes.
straightforward connection of endoscope ports to the of your reprocessing cycle. You can monitor your values
ready-to-use innovative adapter sets, with the same during each process on the user-friendly touch display, Compliance with EN ISO 15883
color scheme for all dedicated adapter sets. and this data is also available upon cycle completion in The Olympus ETD Double is fully compliant with EN ISO
the process-specific record. 15883 -1 and 15883-4. This has been proven with type
Furthermore, many connecting pieces are equipped with testing and thorough microbiological testing at a variety
a laser-engraved icon displaying the suitable endoscope of independent hygiene institutes.
port. Together, these significantly increase secure and
11155

rapid connection of adapter sets. Incorrect connection


of Olympus endoscopes is prevented by a mechanical Mechanically coded adapter with laser-engraved icon.

lock, enhancing safety during adaptation.

Comprehensive Leakage Test Functionality


The automated leakage test of the ETD Double provides
you with precise and stable sensors and pumps for high
detection rates of even the finest leaks.
11156

Color-coded adaptation principle.

Enhanced RFID-Based Tracing Technology


Olympus RFID-based tracing technology helps to significantly enhance your process safety by extending
traceability and transparency:
·· The ETD Double is compatible with a variety of traceability solutions, including Olympus ENDOALPHA
Documentation
·· This enables the clear identification of your endoscopes, users, and chemicals
·· Three antennas inside the washing chamber allow the accurate identification of your endoscopes
·· Your users conveniently scan their RFID cards before the start and after the completion of a reprocessing cycle
·· This ensures the allocation of reprocessing sequences to the executing team member in order to highlight their
respective responsibilities
11151
ADVANCING HYGIENE

The ETD Double Is Your Reliable Partner in Endoscope Reprocessing. Thanks to Individual Channel
Monitoring in up to Seven Channels and an Advanced Air- and Water-Pressure Principle for Inner and
Outer Endoscope Reprocessing, Excellent Hygienic Results Can Be Achieved.

Detection of Blockages at the Individual Channel Level


The ETD Double allows the separate connection of up to seven endoscope channels, so even the most complex
endoscopes can be connected. A completely new flow-control system has been developed to effectively detect
faulty reprocessing conditions inside function-compatible endoscopes, which include:
·· Blocked channels
·· Incorrectly connected adapters
·· Unconnected adapters

The preinstalled set of reference data for each individual endoscope channels omits the need for manual entry of
reference volumes for your endoscopes. This reference data is updated regularly during maintenance or servicing to
ensure availability of the latest information.

Flow monitoring is applied in every process step, ensuring comprehensive screening throughout the entire process.

Effective Self-Disinfection
ETD Double’s self-disinfection process:
·· Operates daily
·· Is automatic
·· Can be preprogrammed
·· Can be activated automatically prior to your daily work schedule
·· Guarantees a safe start to your day from the very first cycle

Advanced Cleaning Results


P Excellent cleaning
results
Innovative,
Optimized water Two powerful, P Reduction of
powerful air flush
pressure for inner monitored spray carryover effects
at the end of each
channel flushing arms
process step
P High outer
endoscope
cleaning standards
11150
CUSTOMIZED SERVICE AND SUPPORT
Stainless-steel casing

Modular Olympus Services


With the ETD Double, Olympus offers a high-quality solution in combination with a well-conceived service portfolio.

With this modular approach, you can:


·· Create the solution that fits your work flow
Glass sliding door ·· Increase efficiency
·· Reduce costs

Expert Maintenance
Touch display You will also benefit from the expert Olympus support
service that is always on hand for preventive or
Antenna for user card
corrective maintenance. Detecting minor damage before
major repairs are required maximizes uptime while
RFID antenna for
endoscope Detection minimizing costs.

Essential Validation
Up to three endoscopes
can be loaded Color-and-mechanically The validation module includes the full range of
coded adapter set
operational and performance qualification tests in
compliance with the requirements of EN ISO 15883-1
Universal one-fits-all basket

3024
and 15883-4. These tests monitor and document the
Lower spray arm reliability and security of your endoscope reprocessing
work flow end-to-end.

3079
Convenient Remote Service
The remote service module gives our engineers efficient
remote access to your equipment. Troubleshooting can
be performed centrally, minimizing downtime due to on-
Loading trolley docking point site visits to your facility.

Process chemistry and Expert Help-Desk Support


RFID antennas for
canister detection The Olympus help desk is here during business hours
to answer all your queries, troubleshoot problems with
you, and, when needed, refer you to the right Olympus
specialist to help you.

Focused Training
All relevant staff members receive dedicated modular
training in how to handle Olympus equipment, so you
can be sure that you are getting the best from your
ETD Double at all times.
11149
ETD DOUBLE

ETD Double

Type/versions ETD Double


Capacity 3 flexible medical endoscopes
Process Compatible with Olympus PAA process chemistry
·· Standard programs for flexible medical endo-
scopes with different drying options
Specifications Programs
·· Thermoprogram for rigid instruments
·· Thermal self-disinfection
Outer casing and frame Stainless steel
Interfaces LAN printer port
User interface 7-inch multicolor touch displays on both sides
Dimensions ETD Double unit W × D × H: 900 × 830 × 2140 mm
Weight ETD Double unit ≤570 kg
Process water: Cold water and/or demineralized
Water hardness: Max. 4°dH
water water and/or cold water (drinking water
Temperature: Max. 30°C
Water Supply according to microbiological quality)
Water for optional steam condenser (cooling circuit Tap water
is also possible) Temperature: Max. 20 °C
Voltage / frequency 400 V / 50 Hz
Electric Power Supply Fuses 3 × 16 A
Power consumption 10.5 kW
Ambient Operating Ambient temperature 5–40°C
Conditions Relative humidity 10–80% at max. 30°C
Plumbing DN50
Discharge
Floor-level drain or optional drain pump
Connections Height of discharge connection
(height max. 1.5 m)
·· Manufactured according to DIN EN ISO 13485
·· Manufactured according to DIN EN ISO 9001
Certificates ·· Manufactured according to DIN EN ISO 14001
·· CE marking according to 93/42/EWG, Class IIb
·· Fulfils DIN EN ISO 15883-1/2/4
Compliance Status Safety Fulfills DIN EN 61010-2-40
In accordance with 2004/108/EC directive
EMC
Fluid category 5
Protection against pollution of potable water Fulfills DIN EN 1717
RoHS In accordance with 2011/65/EC RoHS directive
E0428736 · 1.500 · 11/14 · OEKG · ED

Specifications, design, and accessories are subject to change without any notice or obligation on the part of the manufacturer.

Postbox 10 49 08, 20034 Hamburg, Germany


Wendenstrasse 14–18, 20097 Hamburg, Germany
Phone: +49 40 23773-0, Fax: +49 40 233765
www.olympus-europa.com

You might also like