SKMW30 & DKMW30: 30W 1"x1" Package DC-DC Regulated Converter
SKMW30 & DKMW30: 30W 1"x1" Package DC-DC Regulated Converter
SKMW30 & DKMW30: 30W 1"x1" Package DC-DC Regulated Converter
■ Features ■ Applications
DIP 1"x1" package with industry standard pinout Telecom/ datacom system
4:1 ultrawide input range Wireless network
Operating temperature range -40 ~ +85℃ Industrial control facility
No minimum load required Instrument
Comply to BS EN/EN55032 radiated Class A without Analyzer
additional components Detector
High efficiency up to 90%
Data switch
Protections: Short circuit (Continuous) / Overload /
Over voltage / Over temperature / Input under voltage
1.5KVDC I/O isolation
Remote ON/OFF control and Triming output (±10%)
3 years warranty
■ Description
SKMW30 and DKMW30 series are 30W isolated and regulated module type DC-DC converter with DIP 1"x1"
package. It features international standard pins, a high efficiency up to 90%, wide working temperature
range -40~+85℃, 1.5KVDC I/P-O/P isolation voltage, compliance to BS EN/EN55032 radiated Class A
without additional components, continuous-mode short circuit, overload, over temperature, input under
voltage protection, remote ON/OFF and trimmable output voltage etc. The models account for different
input voltage 9~36V and 18~75V 4:1 ultrawide input range, and various output voltage, 3.3V/5V/12V/15V
for single output and ±12V/±15V for dual outputs, which are suitable for all kinds of systems, s uch
as industrial control, telecommunication field, distributed power architecture, and so on.
■ Model Encoding
S KMW30 F - 12
SKMW30F-12
24V 10mA 1404mA 12V 0~2500mA 89% 2500μF
(9 ~ 36V)
48V
SKMW30G-15 (18 ~ 75V) 8mA 702mA 15V 0~2000mA 89% 2000μF
R-Load
R trim-up Trim
-Vin -Vo -Vin -Vo
1. The value of Rtrim - up defined as: Table 1 – Trim up and Trim down Resistor Values
Output R1 R2 R3 Rt Vr
V r × R1 × (R2 + R3) Model Number
R trim − up = ( ) − Rt (K Ω) Voltage(V) (KΩ) ( KΩ) ( KΩ) (KΩ) (V)
( V o − V o , nom ) × R2
SKMW30F - 0 3
Where 3.3 2.74 1.8 0.27 9.1 1.24
SKMW30G - 0 3
R trim -up is the external resistor in Kohm. SKMW30F - 05
5.0 2.32 2.32 0 8.2 2.5
V o , nom is the nominal output voltage. SKMW30G - 05
V o is the desired output v oltage. SKMW30F - 12
12.0 6.8 2.4 2.32 22 2.5
R1, Rt, R2, R3 and Vr are internal to the unit and are defined in Table 1. SKMW30G - 12
SKMW30F - 15
15.0 8.06 2.4 3.9 27 2.5
SKMW30G - 15
For example, to trim-up the output voltage of 5.0V module (SKMW30F-05) by 10% to 5.5V, R trim-up is calculated as follows:
V o – V o,nom = 5.5 – 5.0 = 0.5V
R1 = 2.32 KΩ
R2 = 2.32 KΩ
R3 = 0 KΩ
Rt = 8.2 KΩ
Vr = 2.5V
V r × R1
R trim − down = R1 × ( − 1 ) − Rt (K Ω)
( V o , nom − V o ) × R2
Where
R trim-down is the external resistor in Kohm.
V o , nom is the nominal output voltage.
V o is the desired output voltage.
R1, Rt, R2, R3 and Vr are internal to the unit and are defined in Table 1.
For example, to trim-down the output voltage of 5.0V module (SKMW30F-05) by 10% to 4.5V, R trim-down is calculated as follows:
V o,nom – V o = 5.0 – 4.5 = 0.5V
R1 = 2.32 KΩ
R2 = 2.32 KΩ
R3 = 0 KΩ
Rt = 8.2 KΩ
Vr = 2.5V
2.5 × 2.32
R trim − down = 2.32 × ( − 1 ) − 8.2 = 1.08 (K Ω)
0.5 × 2.32
5.08(0.2)
2.5(0.1)
7.62(0.3) 10.2(0.4)
6 2 1
20.32(0.8)
25.4(1)
1(0.04)
5 4 3
10.16(0.4) 10.16(0.4)
Pin-Out
SKMW30 DKMW30 100
Pin No. (Single output) (Dual output)
LOAD (%)
80
1 +Vin +Vin
60
2 -Vin -Vin
40
3 +Vout +Vout Natural convection
20
4 Trim Common
-40 -20 0 20 40 55 70 85 105
5 -Vout -Vout
Installation Manual
Please refer to : http://www.meanwell.com/manual.html