Rexroth Cartridge EV

Download as pdf or txt
Download as pdf or txt
You are on page 1of 62

Componenti s.r.l.

VALVOLE ELETTRICHE
Solenoid valves GUIDA SELEZIONE PRODOTTI
Product selection guide

Bobine e connettori Potenza


Power ED Connettore Tensione
Voltage Pag
Coils and connections (W)
Connections
(V)
12Vdc
S1-MCE 18 25% Faston
24Vdc
2.52.01

S2-CE 18 100% Hirschmann 24V-50Hz


48V-50Hz
110V-50Hz
220V-50Hz
Cavi 380V-50Hz
S2-CE-C 18 100%
Cables 24V-60Hz
2.52.02
48V-60Hz
110V-60Hz
220V-60Hz
380V-60Hz

S-CE 18 100% Hirschmann 12Vdc


24Vdc
48Vdc
24V RAC
Cavi
S-CE-C 18 100% Cables
48V RAC
110V RAC
220V RAC
2.52.06
S-CE-H (classe H 180°C) 18 100% Hirschmann
S-CE-K 18 100% Kostal M27x1 12Vdc
24Vdc
S-CE-A 18 100% AMP Junior
Deutsch
S-CE-D 18 100%
DT04-2P

12Vdc
S4-CEI 26 100% Hirschmann
24Vdc
48VDC
Cavi 24V RAC
S4-CEI-C 26 100%
Cables 48V RAC
110V RAC
220V RAC 2.50.10
S4-CEI-K 26 100% Kostal M27x1
12Vdc
S4-CEI-VK (varistore) 26 100% Kostal M27x1 24Vdc
Deutsch
S4-CEI-D 26 100% DT04-2P

12Vdc
24Vdc
S-V3D 60 35% Hirschmann 48VDC 2.50.12
110V RAC
220V RAC

Hirschmann 12Vdc
Cavi - Cables 24Vdc
S8 (EDY SISTEM) 17 100% Kostal M27x1 48VDC 2.50.18
AMP Junior 110V RAC
220V RAC

1.05.05
Componenti s.r.l.

VALVOLE ELETTRICHE
Solenoid valves GUIDA SELEZIONE PRODOTTI
Product selection guide

VALVOLE A 2 VIE DIRETTE


2 WAY DIRECT ACTING VALVES
Normalmente chiuse, tenuta singola Q max P max Bobina Pag
Normally closed, one way lock (l/min) (bar) Coil

VED-NC 1,5 210 S-CE 2.52.01

VALVOLE A 2 VIE PILOTATE A TENUTA SINGOLA


2 WAY PILOT OPERATED VALVES
Normalmente chiuse, tenuta singola Q max P max Bobina Pag
Normally closed, one way lock (l/min) (bar) Coil

MCE1-NC 20 210 S1-MCE 2.52.04


VE1-NC (A.C. current) 40 350 S2-CE 2.52.05
VE3-NC (D.C. current) 40 350 S-CE 2.52.10
VEI-8A-2A-06-NC-D-ET 20 250 S8 2.52.12
CEI6-NC 45 350 S-CE 2.52.29
CEI10-NC 70 350 S-CE 2.52.35
CEI12-NC 150 350 S-CE 2.52.39

Normalmente chiuse, monodirezionali a tenuta singola con ritegno Q max P max Bobina Pag
Normally closed, one way flow, one way lock and check valve (l/min) (bar) Coil

VE1-NC-VU (A.C. current) 30 250 S2-CE 2.52.05


VE3-NC-VU (D.C. current) 30 250 S-CE 2.52.10

Normalmente aperte, a tenuta singola Q max P max Bobina Pag


Normally open, one way lock (l/min) (bar) Coil

VE3-NA 30 250 S-CE 2.52.14


CEI6-NA 45 350 S-CE 2.52.43
CEI10-NA 70 350 S-CE 2.52.45
CEI12-NA 150 350 S-CE 2.52.47

Normalmente aperte, monodirezionali a tenuta singola con ritegno Q max P max Bobina Pag
Normally open, one way flow, one way lock and check valve (l/min) (bar) Coil

VE3-NA-VU 30 250 S-CE 2.52.14

VALVOLE A 2 VIE DIRETTE A DOPPIA TENUTA


2 WAY DOUBLE LOCK VALVES
Normalmente chiuse, doppia tenuta Q max P max Bobina Pag
Normally closed, double lock (l/min) (bar) Coil

CE3-DT 15 210 S-CE 2.52.52


CEI16-DT 30 230 S4-CEI 2.52.60

1.05.06
Componenti s.r.l.

VALVOLE ELETTRICHE
Solenoid valves GUIDA SELEZIONE PRODOTTI
Product selection guide

Normalmente aperte, doppia tenuta Q max P max Bobina Pag


Normally open, double lock (l/min) (bar) Coil

CEI16NA-DT 30 230 S4-CEI 2.52.66

VALVOLE A 2 VIE PILOTATE A DOPPIA TENUTA


2 WAY PILOT OPERATED, DOUBLE LOCK VALVES
Normalmente chiuse, doppia tenuta Q max P max Bobina Pag
Normally closed, double lock (l/min) (bar) Coil

VEI-8A-2T-06-NC-S 40 350 S8 2.52.70


VEI-8A-2T-09-NC-S 70 350 S8 2.52.70
VEI-8A-2T-12-NC-S 150 350 S8 2.52.70

Normalmente aperte, doppia tenuta Q max P max Bobina Pag


Normally open, double lock (l/min) (bar) Coil

VEI-8A-2T-06-NA-S 40 350 S8 2.52.72


VEI-8A-2T-09-NA-S 70 350 S8 2.52.72
VEI-8A-2T-12-NA-S 150 350 S8 2.52.72

VALVOLE A 3 VIE 2 POSIZIONI DIRETTE


3 WAY 2 POSITION, DIRECT ACTING VALVES
A tenuta Q max P max Bobina Pag
Poppet style (l/min) (bar) Coil

V3D-DT 20 250 S4-CEI 2.53.02


V3D-CE 25 300 S-V3D 2.53.06

A cursore – selettrici Q max P max Bobina Pag


Spool style – selector (l/min) (bar) Coil

V3DS-2P 8 210 S-CE 2.53.10


V3DS4-2P 20 210 S4-CEI 2.53.14

A cursore – Normalmente chiuse Q max P max Bobina


Pag
Spool style – Normally closed (l/min) (bar) Coil

V3DS-2P 8 210 S-CE 2.53.10


V3DS4-2P 20 210 S4-CEI 2.53.14

A cursore – Normalmente aperte Q max P max Bobina Pag


Spool style – Normally open (l/min) (bar) Coil

V3DS-2P 8 210 S-CE 2.53.10


V3DS4-2P 20 210 S4-CEI 2.53.14

1.05.07
Componenti s.r.l.

VALVOLE ELETTRICHE
Solenoid valves GUIDA SELEZIONE PRODOTTI
Product selection guide

A cursore – Normalmente chiuse con cannotto in spinta Q max P max Bobina Pag
Spool style – Normally closed with pushing tube (l/min) (bar) Coil

V3D-CEI-2P 20 210 S4-CEI 2.53.16

VALVOLE A 4 VIE 2 POSIZIONI DIRETTE A CURSORE


4 WAY 2 POSITION, DIRECT ACTING, SPOOL TYPE VALVES
Centro chiuso Q max P max Bobina Pag
Closed Centre (l/min) (bar) Coil

V4DS-2P 8 210 S-CE 2.54.02


V4DS4-2P 25 315 S4-CEI 2.54.04

Parallelo incrociato Q max P max Bobina Pag


Centre P on A, B on T (l/min) (bar) Coil

V4DS-2P 8 210 S-CE 2.54.02


V4DS4-2P 25 315 S4-CEI 2.54.04

Centro con P in B, A in T – Eccitata con A e B chiusi, P in T Q max P max Bobina Pag


Centre P on B, A on T – Energized A on B, P on T (l/min) (bar) Coil

V4D-CEI-2P 25 315 S4-CEI 2.54.06

Centro con P in T, A e B chiusi Q max P max Bobina Pag


Centre P on T, A and B closed (l/min) (bar) Coil

V4DS4-2P 25 315 S4-CEI 2.54.04

Incrociato - parallelo Q max P max Bobina Pag


Centre P on B, A on T (l/min) (bar) Coil

V4D-CEI-2P 25 315 S4-CEI 2.54.06

VALVOLE A 4 VIE 3 POSIZIONI DIRETTE A CURSORE


4 WAY 3 POSITION, DIRECT ACTING, SPOOL TYPE VALVES
Centro chiuso Q max P max Bobina Pag
Closed Centre (l/min) (bar) Coil

V4DS-3P 8 210 S-CE 2.54.16


V4D-CEI-3P 25 350 S4-CEI 2.54.24

1.05.08
Componenti s.r.l.

VALVOLE ELETTRICHE
Solenoid valves GUIDA SELEZIONE PRODOTTI
Product selection guide

Centro con P chiuso A e B in T Q max P max Bobina Pag


Centre with P closed, A and B to T (l/min) (bar) Coil

V4DS-3P 8 210 S-CE 2.54.16


V4D-CEI-3P 25 315 S4-CEI 2.54.24

Centro con figura ad “H” Q max P max Bobina Pag


Centre “H” figure (l/min) (bar) Coil

V4DS-3P 8 210 S-CE 2.54.16

Centro con P chiuso, A in T, B chiuso Q max P max Bobina Pag


Centre P closed, A to T, B closed (l/min) (bar) Coil

V4DS-3P 8 210 S-CE 2.54.16


V4D-CEI-3P 25 315 S4-CEI 2.54.24

Centro con P in T, A e B chiusi Q max P max Bobina Pag


Centre P on T, A and B closed (l/min) (bar) Coil

V4D-CEI-3P 25 315 S4-CEI 2.54.24

CIRCUITI INTEGRATI
INTEGRATED BLOCKS
Valvola elettrica per comando cilindro a semplice effetto Q max P max Bobina Pag
Solenoid valve for single acting cylinder (l/min) (bar) Coil

CE6-VM-VU-ST 25 300 S-CE 2.56.02


CE1-VM-VU-STF14 10 250 S-CE 2.56.04

Valvola di massima con by-pass a comando elettrico Q max P max Bobina Pag
Relief valve with solenoid operated by-pass (l/min) (bar) Coil

CE6-VM25 25 300 S-CE 2.56.06

Valvola di massima pilotata elettricamente Q max P max Bobina Pag


Ventable pilot operated relief valve (l/min) (bar) Coil

VM15-CE 150 250 S-CE 2.56.08

1.05.09
Componenti s.r.l.

SOLENOIDI CON CONNETTORE PER CARTUCCE SERIE “M-CE”


Coils with connector for cartridge “M-CE” series

S1-MCE (18 Watt ED25%) DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code C1.664.15.XY.0

Trattasi di una serie di bobine realizzata per l’uso con elettrovalvola della
Tensioni
XY Voltage
serie miniatura “M-CE”.
Alle due estremità della bobina sono alloggiate due guarnizioni per
protezione dagli agenti atmosferici.
OB 12 Volts C.C. - D.C.
• Bobina disponibile solo con attacco Faston
OC 24 Volts C.C. - D.C.
• Rivestimento bobina: resina polimmidica caricata con fibra di vetro
• Servizio intermittente ED25% per un tempo massimo di eccitazione
di 15 min a 20°C.
• Voltaggio minimo richiesto: 90% della tensione nominale.
• Grado di protezione: IP00 IEC 144 – DIN 40050

Classe di isolamento F (155°C)

This is a serie of coils to be used with miniature solenoid valves


“M-CE” type.
On the two extremities of the coils there are two seal for protection against
dust and water jets.
• This coil is available with Faston connections only.
• Coil protection: polyamide resin with fiber glass
• Duty service ED25% for a maximum excitation of 15 min at 20°C.
• Minimum voltage: 90% of the nominal voltage.
• Protection degree: IP00 IEC 144 – DIN 40050.

Insulation class F (155°C)

2.50.01
Componenti s.r.l.

SOLENOIDI CON CONNETTORE


Coils with connector

S2-CE (18 Watt ED100%) DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code C1.664.01.XY.Z
S2-CE-C (18 Watt ED100%) C1.664.08.XY.1

Trattasi di una serie di bobine realizzata per l’uso con elettrovalvole della
Tensioni serie “VE1”.
XY Voltage Alle due estremità della bobina sono alloggiate due guarnizioni OR2056
per protezione dagli agenti atmosferici.
• Rivestimento bobina: resina poliammidica caricata con fibre di vetro.
• Voltaggio minimo richiesto: 90% della tensione nominale.
• Grado di protezione: IP65 IEC 144 – DIN 40050 (protezione totale
OH 24 Volts 50 Hz C.A. - A.C.
contro polvere e acqua spruzzata in getti a bassa pressione).
OL 48 Volts 50 Hz C.A. - A.C.
OM 110 Volts 50 Hz C.A. - A.C.
ON 220 Volts 50 Hz C.A. - A.C. Classe di isolamento F (155°C)
OO 380 Volts 50 Hz C.A. - A.C.
OP 24 Volts 60 Hz C.A. - A.C.
OQ 48 Volts 60 Hz C.A. - A.C.
OR 110 Volts 60 Hz C.A. - A.C.
OS 220 Volts 60 Hz C.A. - A.C.
OT 380 Volts 60 Hz C.A. - A.C. This is a serie of coils to be used with solenoid valves “VE1” types.
On the two extremities of the coils there are two seal OR2056 for protection
against dust and water jets.
• Coil protection: Polyamide resin with fiber glass.
• Minimum voltage: 90% of the nominal voltage.
• Protection degree: IP65 IEC 144 – DIN 40050 (total protection against
dust and low pressure jets)
Z Connettori - Connectors type
1 Senza connettore Without connector
Insulation class F (155°C)
2 Connettore standard Standard connector

2.50.02
Componenti s.r.l.

SOLENOIDI CON CONNETTORE


Coils with connector

S-CE (18 Watt ED100%) DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code C1.664.55.XY.Z
S-CE-H (18 Watt ED100%)
Insulation class H 180°C C1.664.62.XY.Z
S-CE-K (18 Watt ED100%) C1.664.56.XY.Z
S-CE-C (18 Watt ED100%) C1.664.57.XY.1
S-CE-A (18 Watt ED100%) C1.664.58.XY.1
S-CE-D (18 Watt ED100%) C1.664.63.XY.1
S-CE-H
S-CE-K
S-CE-A
S-CE-D

Tensioni
New
S-CE

XY Voltage

OB 12 Volts C.C. - D.C. • • • • •


OC 24 Volts C.C. - D.C. • • • • • Trattasi di una serie di bobine potenziate, a disegno Oil Sistem.
OD 48 Volts C.C. - D.C. • • Rivestimento bobina: resina poliammidica caricata con fibre di vetro.
• I solenoide S-CE (18 W) sono dimensionati per servizio continuo ED100%.
• Voltaggio minimo richiesto: 90% della tensione nominale.
• Grado di protezione: IP65 IEC 144 – DIN 40050 (protezione totale contro polvere
e acqua spruzzata in getti a bassa pressione).

Classe di isolamento F (155°C)

This is a serie of Oil Sistem coils more powerful.


• Coil protection: Polyamide resin with fiber glass.
• Solenoids “S-CE” (18 W) are designed for continuos duty ED100%.
• Minimum voltage: 90% of the nominal voltage.
OV 24 Volts RAC • • Protection degree: IP65 IEC 144 – DIN 40050 (total protection against dust and
OK 48 Volts RAC • low pressure jets)

OW 110 Volts RAC •


Insulation class F (155°C)
OZ 220 Volts RAC •

Z Connettori - Connectors type


1 Senza connettore Without connector 3 Connettore con raddrizzatore Connector with rectifier
2 Connettore standard Standard connector 4 Connettore attacco Kostal Kostal connector

2.50.06
Componenti s.r.l.

SOLENOIDI CON CONNETTORE


Coils with connector

S4-CEI (26 Watt ED100%) DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code C1.664.37.XY.Z
S4-CEI-K (26 Watt ED100%) C1.664.44.XY.Z
S4-CEI-VK (26 Watt ED100%)
(Varistore) C1.664.45.XY.Z
S4-CEI-C (26 Watt ED100%) C1.664.51.XY.1
S4-CEI-D (26 Watt ED100%) C1.664.61.XY.1

S4-CEI-VK
S4-CEI-K

S4-CEI-D

Tensioni
S4-CEI

XY Voltage
Trattasi di una serie di bobine realizzata per l’uso con elettrovalvole della serie “CEI”.
Alle due estremità della bobina sono alloggiate due guarnizioni OR2062 per protezione
OB 12 Volts C.C. - D.C. • • • • dagli agenti atmosferici.
OC 24 Volts C.C. - D.C. • • • • • Rivestimento bobina: resina poliammidica caricata con fibre di vetro.
OD 48 Volts C.C. - D.C. • • I solenoidi S4-CEI (26 W) sono dimensionati per servizio continuo ED100%.
• Voltaggio minimo richiesto: 90% della tensione nominale.
• Grado di protezione IP65 IEC 144 – DIN 40050 (protezione totale contro polvere
e acqua spruzzata in getti a bassa pressione).

Classe di isolamento F (155°C)

This is a serie of coils to be used with solenoid valves “CEI” types.


On the two extremities of the coils there are two seal OR2062 for protection against
dust and water jets.
• Coil protection: Polyamide resin with fiber glass.
• Solenoids “S4-CEI” (26 W) are designed for continuos duty ED100%.
• Minimum voltage: 90% of the nominal voltage.
OV 24 Volts RAC • • Protection degree: IP65 IEC 144 – DIN 40050 (total protection against dust and low
OK 48 Volts RAC • pressure jets)
OW 110 Volts RAC •
Insulation class F (155°C)
OZ 220 Volts RAC •

Z Connettori - Connectors type


1 Senza connettore Without connector 3 Connettore con raddrizzatore Connector with rectifier
2 Connettore standard Standard connector 4 Connettore attacco Kostal Kostal connector

2.50.10
Componenti s.r.l.

SOLENOIDI CON CONNETTORE PER CARTUCCE SERIE “V3D-CE”


Coils with connector for cartridge “V3D-CE” series

S-V3D (60 Watt ED35%) DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code C1.664.25.XY.Z

Trattasi di una serie di bobine realizzata per l’uso con elettrovalvole della
Tensioni
XY Voltage
serie “V3D-CE”.
Alle due estremità della bobina sono alloggiate due guarnizioni OR2087
per protezione dagli agenti atmosferici.
OB 12 Volts C.C. - D.C.
• Rivestimento bobina: resina poliammidica caricata con fibre di vetro.
OC 24 Volts C.C. - D.C.
• I solenoidi S-V3D (60 W) sono dimensionati per servizio intermittente
OD 48 Volts C.C. - D.C.
ED35% e tempo max di eccitazione 21 min riferito a 20°C.
• Voltaggio minimo richiesto: 90% della tensione nominale.
• Grado di protezione: IP65 IEC 144 – DIN 40050 (protezione totale
contro polvere e acqua spruzzata in getti a bassa pressione).

Classe di isolamento F (155°C)

This is a serie of coils to be used with solenoid valves “V3D-CE” types.

OW 110 Volts RAC On the two extremities of the coils there are two seal OR2087 for protection

OZ 220 Volts RAC against dust and water jets.


• Coil protection: Polyamide resin with fiber glass.
• Solenoids “S-V3D” (60 W) are designed for intermittent duty ED35%
Connettori and for an excitation time of 21 min at 20°C.
Z Connectors type • Minimum voltage: 90% of the nominal voltage.
• Protection degree: IP65 IEC 144 – DIN 40050 (total protection against
1 Senza connettore Without connector
dust and low pressure jets)
2 Connettore standard Standard connector
3 Connettore con raddrizzatore Connector with rectifier
Insulation class F (155°C)

2.50.12
Componenti s.r.l.

SOLENOIDI CON CONNETTORE


Coils with connector

S8 (17 Watt ED100%) DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code OD.02-K-X.Y-Z
Prodotto Edi System
Edi System product

Descrizione
Description
Queste bobine sono incapsulate in resina poliammidica (nylon 6) caricata con fibra di vetro ( isolamento termico in CLASSE F ) o in RYNITE ( isolamento
termico in CLASSE H - omologato UL ).
• Peso : 0.180 kg
• La tensione di alimentazione non deve subire variazioni superiori al ( 10% per il buon funzionamento delle bobine.
These coils are housed in polyamide resin casing (nylon 6) reinforced with fiberglass ( CLASS F insulation ) or RYNITE ( CLASS H insulation - UL
approved ).
• Weight : 0.180 kg
• Inlet voltage fluctuations must not exceed ( 10% to obtain correct operation and long life of coils.

Isolamento termico Temperatura


K Heat insulation Temperature

11 Classe F - Class F 155$C


12 Classe H - Class H 180$C

Connessioni Circuito Tensione


X.Y Connections Circuit Voltage

01.30 DIN 43650 - ISO Standard DC - RAC


02.2A Double Lead Standard DC
03.30 Costal M27x1 Standard DC
07.30 AMP Junior Standard DC

Resistenza Potenza Corrente


Tensione nominale Resistance Power Current 6T
Z Nominal Voltage (1) (W) (I) $C
(V)
Ta= 20-25 $C Bobina fredda Bobina fredda Bobina calda Dopo 1 ora a Ta= 20-25$C
Cold coil Cold coil Hot coil After 1 hour at 20-25$C
OB 12V dc 8,7 17 1,38 0,97
OC 24V dc 33 17 0,71 0,51 Tensione nominale
Nominal Voltage
OV 24V RAC 27 17 0,81 0,65
OW 110V RAC 564 17 0,19 0,15 105-110
OZ 220V RAC 2323 17 0,09 0,07

2.50.18
Componenti s.r.l.

CONNETTORI
Connectors

CONNETTORE STANDARD attacco


HIRSCHMANN DIN 43650

STANDARD CONNECTOR type


HIRSCHMANN DIN 43650
STANDARD TYPE
- Nominal current: 10 A
- Max operating current: 16 A
- Contact resistance: 4 mOhm
- Max Cond. Cross-section: 1,5 mm2
- Protection class: IP 65 EN60529
- Insulation class: VDE 0110-1/89
CODICE
Code C1.600.01.000

CONNETTORE STANDARD attacco


HIRSCHMANN DIN 43650

S TA N D A R D C O N N E C T O R type
HIRSCHMANN DIN 43650
SPECIAL TYPE CABLE PG11
- Nominal current: 10 A
- Max operating current: 16 A
- Contact resistance: 4 mOhm
- Max Cond. Cross-section: 1,5 mm2
- Protection class: IP 65 EN60529
- Insulation class: VDE 0110-1/89
CODICE
Code C1.600.01.011

CONNETTORE STANDARD attacco


HIRSCHMANN DIN 43650

S TA N D A R D C O N N E C T O R type
HIRSCHMANN DIN 43650

- Nominal current: 10 A
- Max operating current: 16 A
- Contact resistance: 4 mOhm
- Max Cond. Cross-section: 1,5 mm2
- Protection class: IP 65 EN60529
- Insulation class: VDE 0110-1/89
CODICE
Code C1.600.12.000

CONNETTORE attacco DIN43650 con


DIODO di blocco sovra tensione in apertura

CONNECTOR type DIN 43650 with DIODE


to stop over voltage on opening.

- Nominal current: 10 A
- Max operating current: 16 A
- Contact resistance: 4 mOhm
- Max Cond. Cross-section: 1,5 mm2
- Protection class: IP 65 EN60529
- Insulation class: VDE 0110-1/89
CODICE
Code C1.600.17.000

CONNETTORE attacco DIN43650 con led


bipolare + VDR di protezione contro le
sovra tensioni provenienti
dall’alimentazione e dal carico all’apertura.

CONNECTOR type DIN 43650 with led


and VDR to protect supply and switch (the
voltageon the coil is limited by the VDR)

- Nominal current: 10 A
- Max operating current: 16 A
- Contact resistance: 4 mOhm
- Max Cond. Cross-section: 1,5 mm2
CODICE
Code C1.600.13.000 - Protection class: IP 65 EN60529
- Insulation class: VDE 0110-1/89

2.50.20
Componenti s.r.l.

CONNETTORI
Connectors

CONNETTORE STANDARD attacco


HIRSCHMANN DIN 43650 con ponte
raddrizzatore a 4 diodi interno.

STANDARD CONNECTOR type


HIRSCHMANN DIN 43650 with full wave
STANDARD TYPE bridge rectifier (4 diode)
- Nominal current: 10 A
- Max operating current: 16 A
- Contact resistance: 4 mOhm
- Max Cond. Cross-section: 1,5 mm2
- Protection class: IP 65 EN60529
- Insulation class: VDE 0110-1/89
CODICE
Code C1.600.03.000

CONNETTORE con attacco


HIRSCHMANN DIN 43650 con ponte
raddrizzatore a 4 diodi interno.
CONNECTOR type HIRSCHMANN DIN
43650 with full wave bridge rectifier (4
SPECIAL TYPE CABLE PG11 diode)

- Nominal current: 10 A
- Max operating current: 16 A
- Contact resistance: 4 mOhm
- Max Cond. Cross-section: 1,5 mm2
- Protection class: IP 65 EN60529
- Insulation class: VDE 0110-1/89
CODICE
Code C1.600.03.001

CONNETTORE con attacco


HIRSCHMANN DIN 43650 con ponte
raddrizzatore a 4 diodi + VDR di protezione
contro le sovra tensioni provenienti
dall’alimentazione e dal carico all’apertura.

CONNECTOR type HIRSCHMANN DIN


43650 with full wave bridge rectifier (4
diode) + VDR to protect against supply
over voltage

- Nominal current: 10 A
- Max operating current: 16 A
- Contact resistance: 4 mOhm
- Max Cond. Cross-section: 1,5 mm2
CODICE
Code C1.600.18.000 - Protection class: IP 65 EN60529
- Insulation class: VDE 0110-1/89

CONNETTORE STANDARD attacco


KOSTAL

STANDARD CONNECTOR type KOSTAL


(only for use with DC input)
- Nominal current: 10 A
- Max operating current: 16 A
- Contact resistance: 4 mOhm
- Max Cond. Cross-section: 1,5 mm2
- Protection class: IP 65 EN60529
- Insulation class: VDE 0110-1/89

CODICE
Code C1.600.07.000

2.50.22
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE MONODIREZIONALI DIRETTE


2 way direct acting solenoid valves

VED-NC DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.68.X.Y.1
VED-NC+S-CE 77.896.68.X.Y.1.55.WW.J

Descrizione
Description

Valvola unidirezionale a 2 vie con otturatore conico a


comando elettrico diretta, per piccole portate;
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o
inferiore;
• Voltaggio minimo richiesto: 90% del
nominale;
• Caratteristiche solenoide:
(vedi pag. 2.50.06)

Solenoid valve 2 way direct acting, poppet style, for


small flow rate;
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of
nominal;
• Coil features: (see on page 2.50.06).

Funzioni possibili con solenoide:


X Schema Operating features with solenoid:
Symbol Diseccitato Eccitato
De-energized Energized

P A PAA
A $
AAP* AAP

A P AAP
G $
PAA* PAA

*) Funzione sconsigliata a causa dell’alto 6P


*) Because of the high pressure drop, this features are not
suggested.

Lo schema “G” è fornito senza filtro


Pressione max di lavoro Portata max “G” circuit is delivered without filter

Max working pressure 210 bar Max flow 1,5 l/min


Cavità - Cavity
Solenoidi - Coils Y
N$ F ØD
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
1 V096001 3/4”-16 UNF 15,87
2 V096004 3/4”-16 UNF 12,7
OB 12V dc OW 110V RAC
OC 24V dc OZ 220V RAC
OD 48V dc
OV 24V RAC Corsa - Stroke
OK 48V RAC mm
0,55

Connettori - Connectors
Senza Standard Con raddrizzatore Attacco Kostal Tempi di risposta Apertura - Opening Chiusura - Closing
J Without Standard With rectifier Kostal connector Operating time
1 2 3 4 10-15 ms 25-30 ms

2.52.01
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE MONODIREZIONALI PILOTATE NORMALMENTE CHIUSE


2 way pilot operated solenoid valves normally closed

MCE1-NC DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.28.A.Y.0
MCE1-NC+S1-MCE 77.896.28.A.Y.0.15.WW.0

Descrizione
Description

Valvola unidirezionale pilotata a 2 vie con otturatore


conico, con ingombro esterno ridotto;
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide:
(vedi pag. 2.50.01)

Solenoid valve 2 way pilot operated, poppet style, with


small external dimensions;
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coil features:
(see on page 2.50.01).

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
Symbol Diseccitato Eccitato
De-energized Energized

P A
$
AAP
PAA

Pressione max di lavoro 210 bar Portata max 20 l/min


Max working pressure Max flow

Solenoidi - Coils
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc
Cavità - Cavity
OC 24V dc Y
N$ F ØD
1 V096001 3/4”-16 UNF 15,87
2 V096004 3/4”-16 UNF 12,7

Connettori - Connectors
Attacco Faston Tempi di risposta Apertura - Opening Chiusura - Closing
Faston connection Operating time
26-35 ms 30-45 ms

2.52.04
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE PILOTATE NORMALMENTE CHIUSE


2 way pilot operated solenoid valves, normally closed

VE1-NC DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.69.X.Y.0
VE1-NC+S2-CE 77.896.69.X.Y.0.01.WW.J

PATENTED Descrizione
Description

Soluzione classica pilotata ad otturatore conico,


intercambiabile con le valvole di produzione americana
ed europea;
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.02);
• Protezione superficiale: zincato bianco;

This is a standard 2 way pilot operated valves poppet


style interchangeable with the same American and
European valves
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.02);
.
C .A .
Funzioni possibili con solenoide:
in .C Schema
lo or A Operating features with solenoid:
o
S y f t X Symbol
l en Diseccitato Eccitato
Oncurr De-energized Energized

P A
A $
AAP
PAA

P A
E $
AAP
PAA

P A PAA
C $ A P
A P
$ $
Pressione max di lavoro 350 bar Portata max 40 l/min P A PAA
Max working pressure 250 bar(*) Max flow 30 l/min(*) F $ A P
A P
$ $
(*) Valvola con filtro - Valve with filter
P A PAA
B $
AAP AAP
Solenoidi - Coils
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage P A PAA
M $
AAP AAP
OH 24V 50Hz ac OP 24V 60Hz ac
OL 48V 50Hz ac OQ 48V 60Hz ac Cavità - Cavity
OM 110V 50Hz ac OR 110V 60Hz ac Y
N$ F ØD
ON 220V 50Hz ac OS 220V 60Hz ac
1 V096001 3/4”-16 UNF 15,87
OO 380V 50Hz ac OT 380V 60Hz ac
2 V096004 3/4”-16 UNF 12,7
La valvola con VU (schemi C ed F) può essere assemblata
solamente in cavità V096001 con preforo minimo Ø10 mm
Valves with VU (symbol C and F) can be assembled in cavity
V096001 only. Prehole min. Ø10 mm is requested
Connettori - Connectors
Senza Standard Tempi di risposta Apertura - Opening Chiusura - Closing
J Without Standard
Operating time
1 2 30-40 ms 60-85 ms

2.52.05
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE PILOTATE NORMALMENTE CHIUSE


2 way pilot operated solenoid valves normally closed

VE3-NC DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.71.X.Y.0
VE3-NC+S-CE 77.896.71.X.Y.0.55.WW.J

PATENTED Descrizione
Description
Soluzione classica pilotata ad otturatore conico,
intercambiabile con le valvole di produzione americana
ed europea;
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);
• Protezione superficiale: zincato verde-oliva;

This is a standard 2 way pilot operated valves poppet


style interchangeable with the same American and
European valves
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features (see on page 2.50.06);

. Funzioni possibili con solenoide:


C .C . Schema Operating features with solenoid:
in .C X
o lo or D Diseccitato Eccitato
S y f nt De-energized Energized
l e
Oncurr
P A
A $
AAP
PAA

P A
E $
AAP
PAA

P A PAA
C $ A P
A P
$ $

P A PAA
F $
Pressione max di lavoro 350 bar Portata max 40 l/min A P
$
A P
$
Max working pressure 250 bar(*) Max flow 30 l/min(*)
(*) Valvola con filtro - Valve with filter P A PAA
B $
AAP AAP
Solenoidi - Coils
Tensione Tensione Tensione P A PAA
WW Voltage WW Voltage WW Voltage M $
AAP AAP
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC Cavità - Cavity
Y
Connettori - Connectors N$ F ØD
Senza Standard Con raddrizzatore Attacco Kostal 1 V096001 3/4”-16 UNF 15,87
J Without Standard With rectifier Kostal connector 2 V096004 3/4”-16 UNF 12,7
1 2 3 4 3 V096108 M18x1,5 15
4 V096069 M20x1,5 15
Tempi di risposta Apertura - Opening Chiusura - Closing La valvola con VU (schemi C ed F) può essere assemblata
solamente in cavità V096001 con preforo minimo Ø10 mm
Operating time 30-40 ms 60-85 ms Valves with VU (symbol C and F) can be assembled in cavity
V096001 only. Prehole min. Ø10 mm is requested

2.52.10
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE PILOTATE


2 way pilot operated solenoid valves

VEI-8A-2A-06-NC-D-ET DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code OD.15.05.18.25.Z

Prodotto Edi System


Edi System product
M8 Descrizione
Description
Coppia 3.5(0.5 Nm
Torque 3.5(0.5 Nm Sono valvole ad azionamento elettrico a 2 vie, a tenuta
pilotate, normalmente chiuse a cartuccia indicate per
35.5
applicazioni in cui si richiedono bassi tempi di risposta
e un trafilamento interno praticamente nullo.
• Filtrazione : 25 +m nominali o inferiore
• Minimo Voltaggio Richiesto : 90% del nominale
Solenoidi da ordinare separatamente
87
Two way, pilot operated, normally closed poppet style
114.5
solenoid cartridge valves, designed for applications
requiring fast response time and virtually zero internal
Bobina S8
leakage.
ch.24 • Filtration : 25 +m nominal or better
Coppia 45(6 Nm • Minimum Voltage Required : 90% of nominal
Torque 45(6 Nm Coils must be ordered separately

1 A 27.5

B
2
Ø12.7 e9 Solenoide “S8”
“S8” coil
3/4”-16UNF-2A

Ø34
Funzioni possibili con solenoide:
12 Schema Operating features with solenoid:
10 Symbol Diseccitato Eccitato
Pressionz - Pressure Bar

De-energized Energized
8
2 A
6 48 BAA BAA
A B AAB
4 128
1 B
$
2

0 4 8 12 16 20 24
Portata - Flow l/min

Tempi di risposta Apertura - Opening Chiusura - Closing


Operating time Cavità - Cavity
30-40 ms 60-85 ms
N$ F ØD
Pressione max di lavoro Portata max V096004 3/4”-16 UNF 12,7
Max working pressure 250 bar Max flow 20 l/min

IMPORTANTE: Non superare per nessun motivo la Pressione Z Cavità - Cavity


massima di lavoro, in quanto a pressioni superiori a 300 bar,
la valvola tende ad aprirsi 00 Emergenza a tirare con cavo
Cable operated pull style override
IMPORTANT: Maximum operating pressure must never be
exceeded, since this valve tends to open at pressures over 01 Emergenza a tirare con pomolo
Hand operated pull style override
300 bar

2.52.12
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE PILOTATE NORMALMENTE APERTE


2 way pilot operated solenoid valves, normally open

VE3-NA DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.74.X.Y.0
VE3-NA+S-CE 77.896.74.X.Y.0.55.WW.J

Descrizione
Description

Soluzione classica pilotata ad otturatore conico,


intercambiabile con le valvole di produzione americana
ed europea;
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

This is a standard 2 way pilot operated valves poppet


style interchangeable with the same American and
European valves
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PAA
P A
A AAP $

PAA
E P A
AAP $

PAA P A
C A P $
$ A P
$
PAA P A
Pressione max di lavoro 250 bar Portata max 30 l/min F $
A P
Max working pressure Max flow $ A P
$
PAA P A
B AAP $
AAP
Solenoidi - Coils
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage M
PAA P A
$
AAP AAP
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC Cavità - Cavity
Y
N$ F ØD
1 V096001 3/4”-16 UNF 15,87
Connettori - Connectors 2 V096004 3/4”-16 UNF 12,7
Senza Standard Con raddrizzatore Attacco Kostal La valvola con VU (schemi C ed F) può essere assemblata
J Without Standard With rectifier Kostal connector solamente in cavità V096001 con preforo minimo Ø10 mm
Valves with VU (symbol C and F) can be assembled in cavity
1 2 3 4 V096001 only. Prehole min. Ø10 mm is requested

2.52.14
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE BIDIREZIONALI PILOTATE NORMALMENTE CHIUSE


2 way pilot operated solenoid valves, normally closed

CEI6-NC DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.64.X.Y.0
CEI6-NC+S-CE 77.896.64.X.Y.0.55.WW.J

PATENTED Descrizione
Description

Soluzione classica pilotata ad otturatore conico e cannotto


avvitato.
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

This is a standard 2 way pilot operated valves poppet


style with screwed tube.
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);
.
C .C .
in .C
o lo or D
S y f nt
l e
Oncurr
Funzioni possibili con solenoide:
Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

P A PAA
A $
AAP AAP

P A PAA
E $
AAP AAP

P A PAA
C $ A P
A P
$ $
Tempi di risposta Apertura - Opening Chiusura - Closing
P A PAA
Operating time F $ A P
30-40 ms 70-95 ms A P
$ $
Pressione max di lavoro 350 bar Portata max 45 l/min one
Max working pressure Max flow o v a versi CE
Nu S-
obina
con b rsion with
Solenoidi - Coils ve
New CE coil
Tensione Tensione Tensione S-
WW Voltage WW Voltage WW Voltage
OB 12V dc OV 24V RAC OZ 220V RAC Cavità - Cavity
Y
OC 24V dc OK 48V RAC N$ F ØD
OD 48V dc OW 110V RAC 1 V096001 3/4”-16 UNF 15,87
2 V096004 3/4”-16 UNF 12,7
Connettori - Connectors 4 V096069 M20x1,5 15
Senza Standard Con raddrizzatore Attacco Kostal La valvola con VU (C ed F) può essere assemblata solo in cavità
J Without Standard With rectifier Kostal connector V096001 con preforo minimo Ø11 mm prof. 32.
Valves with VU (C and F) must be assembled in cavity V096001.
1 2 3 4 Pre hole minimum Ø11 mm depth 32 is request.

2.52.29
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE BIDIREZIONALI PILOTATE NORMALMENTE CHIUSE


2 way pilot operated solenoid valves, normally closed

CEI10-NC DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.66.X.0.0
CEI10 -NC+S-CE 77.896.66.X.0.0.55.WW.J

PATENTED Descrizione
Description

Soluzione classica pilotata ad otturatore conico e cannotto


avvitato.
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

This is a standard 2 way pilot operated valves poppet


style with screwed tube.
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);
.
C .C .
in .C
o lo or D
S y f nt
l e
Oncurr
Funzioni possibili con solenoide:
Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

P A PAA
A $
AAP AAP

P A PAA
E $
AAP AAP

P A PAA
C $ A P
A P
$ $

Tempi di risposta Apertura - Opening Chiusura - Closing P A PAA


F $ A P
Operating time A P
$ $
45-60 ms 140-220 ms

Pressione max di lavoro Portata max one


350 bar 70 l/min v a versi CE
Max working pressure Max flow Nu o S-
obina
con b rsion with
Solenoidi - Coils ve
New CE coil
S-
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
Cavità - Cavity
OB 12V dc OV 24V RAC OZ 220V RAC Y
OC 24V dc OK 48V RAC N$ F ØD
OD 48V dc OW 110V RAC V096005 3/4”BSPP 23,5

Connettori - Connectors
Senza Standard Con raddrizzatore Attacco Kostal La valvola con VU (C ed F) può essere assemblata solo in cavità
J Without Standard With rectifier Kostal connector V096005 con preforo minimo Ø18 mm prof. 50.
Valves with VU (C and F) must be assembled in cavity V096005.
1 2 3 4 Pre hole minimum Ø18 mm depth 50 is request.

2.52.35
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE BIDIREZIONALI PILOTATE NORMALMENTE CHIUSE


2 way pilot operated solenoid valves, normally closed

CEI12-NC DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.67.X.0.0
CEI12 -NC+S-CE 77.896.67.X.0.0.55.WW.J

PATENTED Descrizione
Description

Soluzione classica pilotata ad otturatore conico e cannotto


avvitato.
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

This is a standard 2 way pilot operated valves poppet


style with screwed tube.
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
. (see on page 2.50.06);
C .C .
in .C
o lo or D
S y f nt
l e
Oncurr
Funzioni possibili con solenoide:
Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

P A PAA
A $
AAP AAP

P A PAA
E $
AAP AAP

P A PAA
C $ A P
A P
$ $

Tempi di risposta Apertura - Opening Chiusura - Closing P A PAA


F $ A P
Operating time A P
$ $
45-60 ms 180-240 ms

Pressione max di lavoro Portata max one


350 bar 150 l/min v a versi CE
Max working pressure Max flow Nu o S-
obina
con b rsion with
Solenoidi - Coils ve
New CE coil
S-
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
Cavità - Cavity
OB 12V dc OV 24V RAC OZ 220V RAC Y
OC 24V dc OK 48V RAC N$ F ØD
OD 48V dc OW 110V RAC V096006 1”BSPP 30

Connettori - Connectors
Senza Standard Con raddrizzatore Attacco Kostal La valvola con VU (C ed F) può essere assemblata solo in cavità
J Without Standard With rectifier Kostal connector V096006 con preforo minimo Ø25 mm prof. 67.
Valves with VU (C and F) must be assembled in cavity V096006.
1 2 3 4 Pre hole minimum Ø25 mm depth 67 is request.

2.52.39
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE BIDIREZIONALI PILOTATE NORMALMENTE APERTE


2 way pilot operated solenoid valves, normally open

CEI6-NA DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.64.X.Y.0
CEI6 -NA+S-CE 77.896.64.X.Y.0.55.WW.J

Per azionare l’emergenza svitare Descrizione


la ghiera, togliere il solenoide e
riavvitare la ghiera. Description
In order to use the emergency Soluzione classica pilotata ad otturatore conico e cannotto
button, ubscrew the lead, remove avvitato.
the coil and replace the lead. • Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

This is a standard 2 way pilot operated valves poppet


style with screwed tube.
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PAA P A
B AAP $
AAP

PAA P A
M AAP $
AAP

PAA P A
P AAP $
AAP

ne
v a v ersio E
Pressione max di lavoro Portata max Nuo bina S-C
350 bar 45 l/min o
Max working pressure Max flow con b rsion with
ve
New CE coil
Solenoidi - Coils S-
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC Cavità - Cavity
Y
Connettori - Connectors N$ F ØD
1 V096001 3/4"-16 UNF 15,87
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector 2 V096004 3/4"-16 UNF 12,7
1 2 3 4 4 V096069 M20x1,5 15

2.52.43
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE BIDIREZIONALI PILOTATE NORMALMENTE APERTE


2 way pilot operated solenoid valves, normally open

CEI10-NA DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.66.X.0.0
CEI10-NA+S-CE 77.896.66.X.0.0.55.WW.J
Per azionare l’emergenza svitare
la ghiera, togliere il solenoide e
Descrizione
riavvitare la ghiera. Description
In order to use the emergency Soluzione classica pilotata ad otturatore conico e cannotto
button, ubscrew the lead, remove
avvitato.
the coil and replace the lead.
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

This is a standard 2 way pilot operated valves poppet


style with screwed tube.
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PAA P A
B AAP $
AAP

PAA P A
M AAP $
AAP

PAA P A
P AAP $
AAP

ne
v a v ersio E
Pressione max di lavoro Portata max Nuo bina S-C
350 bar 70 l/min o
Max working pressure Max flow con b rsion with
ve
Solenoidi - Coils
New CE coil
S-
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC Cavità - Cavity
Y
Connettori - Connectors N$ F ØD
V096005 3/4"BSPP 23,5
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector
1 2 3 4

2.52.45
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE BIDIREZIONALI PILOTATE NORMALMENTE APERTE


2 way pilot operated solenoid valves, normally open

CEI12-NA DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.67.X.0.0
CEI12-NA+S-CE 77.896.67.X.0.0.55.WW.J
Per azionare l’emergenza svitare
la ghiera, togliere il solenoide e
Descrizione
riavvitare la ghiera. Description
In order to use the emergency Soluzione classica pilotata ad otturatore conico e cannotto
button, ubscrew the lead, remove
avvitato.
the coil and replace the lead.
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

This is a standard 2 way pilot operated valves poppet


style with screwed tube.
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PAA P A
B AAP $
AAP

PAA P A
M AAP $
AAP

PAA P A
P AAP $
AAP

ne
v a v ersio E
Pressione max di lavoro Portata max Nuo bina S-C
350 bar 150 l/min o
Max working pressure Max flow con b rsion with
ve
New CE coil
Solenoidi - Coils S-
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC Cavità - Cavity
Y
Connettori - Connectors N$ F ØD
V096006 1"BSPP 30
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector
1 2 3 4

2.52.47
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE DIRETTE A DOPPIA TENUTA NORMALMENTE CHIUSE


2 way direct acting solenoid valves, double lock normally closed

CE3-DT DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.22.X.Y.Z
CE3-DT+S-CE 77.896.22.X.Y.Z.55.WW.J

Descrizione
Description

Valvole che consentono il libero passaggio o il blocco


a perfetta tenuta dell’olio su entrambe gli utilizzi P ed A;
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

On this valve the oil can pass free or can be perfectly


locked on each ports P & A:
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);

Lato preferenziale di tenuta: P


Preferred side for locking: P

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

P A PAA
A $
A P AAP
$

P A PAA
E $
A P AAP
$

New
Tempi di risposta Apertura - Opening Chiusura - Closing
Operating time
15-20 ms 20-45 ms

Pressione max di lavoro Portata max 15 l/min


Max working pressure 210 bar Max flow 12 l/min(*)
(*) Valvola con filtro - Valve with filter Filtro - Filter
Z
300 micron
Solenoidi - Coils
0 Senza filtro Without filter
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage 1 Con filtro With filter
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC Cavità - Cavity
OD 48V dc OW 110V RAC
Y
N$ F ØD

Connettori - Connectors 1 V096001 3/4"-16 UNF 15,87


2 V096004 3/4"-16 UNF 12,7
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector 3 V096108 M18x1,5 15
1 2 3 4 4 V096069 M20x1,5 15

2.52.52
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE DIRETTE A DOPPIA TENUTA NORMALMENTE CHIUSE


2 way direct acting solenoid valves, double lock normally closed

CEI16-DT DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.46.X.Y.Z
CEI16-DT+S4-CEI 77.896.46.X.Y.Z.37.WW.J

Descrizione
Description

Valvole che consentono il libero passaggio o il blocco


a perfetta tenuta dell’olio su entrambe gli utilizzi P ed A;
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.10);

On this valve the oil can pass free or can be perfectly


locked on each ports P & A:
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.10);

Lato preferenziale di tenuta: P


Preferred side for locking: P
Funzioni possibili con solenoide:
Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

P A PAA
E $
A P AAP
$

Tempi di risposta Apertura - Opening Chiusura - Closing


Operating time
15-25 ms 30-50 ms

Pressione max di lavoro Portata max 30 l/min


Max working pressure 230 bar Max flow 20 l/min(*)
(*) Valvola con filtro - Valve with filter Filtro - Filter
Z
300 micron
Solenoidi - Coils
0 Senza filtro Without filter
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage 1 Con filtro With filter
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC Cavità - Cavity
OD 48V dc OW 110V RAC
Y
N$ F ØD

Connettori - Connectors 5 V096077 7/8"-14 UNF 15,87


6 V096111 M22x1,5 19
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector
1 2 3 4

2.52.60
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE DIRETTE A DOPPIA TENUTA NORMALMENTE APERTE


2 way direct acting solenoid valves, double lock normally open

CEI16NA-DT DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.76.X.Y.Z
CEI16NA-DT+S4-CEI 77.896.76.X.Y.Z.37.WW.J

Descrizione
Description

Valvole che consentono il libero passaggio o il blocco


a perfetta tenuta dell’olio su entrambe gli utilizzi P ed A;
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

On this valve the oil can pass free or can be perfectly


locked on each ports P & A:
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PAA P A
E AAP $
A P
$

Pressione max di lavoro Portata max 30 l/min


Max working pressure 230 bar Max flow 20 l/min(*)
(*) Valvola con filtro - Valve with filter Filtro - Filter
Z
300 micron
Solenoidi - Coils
0 Senza filtro Without filter
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage 1 Con filtro With filter
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC Cavità - Cavity
OD 48V dc OW 110V RAC
Y
N$ F ØD

Connettori - Connectors 5 V096077 7/8"-14 UNF 15,87


6 V096111 M22x1,5 19
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector
1 2 3 4

2.52.66
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE PILOTATE A DOPPIA TENUTA


2 way pilot operated double lock solenoid valves

VEI-8A-2T-06-NC-S DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code OD.15.31.18.Y.00
VEI-8A-2T-09-NC-S OD.15.31.17.Y.00
VEI-8A-2T-12-NC-S OD.15.31.21.Y.00

Descrizione
Description
Sono valvole ad azionamento elettrico a 2 vie a doppia tenuta pilotate Two way, pilot operated, double lock normally closed poppet style solenoid
normalmente chiuse a cartuccia indicate per applicazioni in cui si richiede cartridge valves, designed for applications requiring virtually zero internal
un trafilamento interno praticamente nullo. leakage.
• Filtrazione : 25 +m nominali o inferiore • Filtration : 25 +m nominal or better
• Minimo Voltaggio Richiesto : 90% del nominale • Minimum Voltage Required : 90% of nominal
• Solenoidi da ordinare separatamente • Coils must be ordered separately

Coppia 3.5(0.5 Nm Coppia 3.5(0.5 Nm Coppia 3.5(0.5 Nm

62.5 60.5
65

Bobina S8
Bobina S8 Bobina S8
ch.38
ch.32 Coppia 90(10 Nm
ch.24 Coppia 60(6 Nm
Coppia 45(6 Nm

2 A 49
2 A 27.5 2 A 38

B
1 1 B 1 B
Ø12.7 e9 Ø23.5 e9 Ø30 e9
3/4”-16UNF-2A
G 3/4 G1

Perdite di carico - Pressure drop Perdite di carico - Pressure drop Perdite di carico - Pressure drop
12 12 18
10 10 15
Pressionz - Pressure Bar

Pressionz - Pressure Bar

Pressionz - Pressure Bar

A A A
8 so 8 o 12 o
ver rs rs
B ve ve
6 6 B 9 B
B B B
o o
rso rs rs
4 ve 4 ve 6 ve
A A A
2 2 3

0 8 16 24 32 40 48 0 12 24 32 48 60 72 0 24 48 72 96 120 144
Portata - Flow l/min Portata - Flow l/min Portata - Flow l/min

Opzioni - Options Prodotto Edi System


Y Edi System product
13 37 Standard
18
Con emergenza a vite
PATENTED
47 With emergency screw

Tipo valvola Cavità Pressione max lavoro Portata max


Valve type Cavity Max working pressure Max flow
2 A VEI-8A-2T-06-NC-S V096004 350 bar 40 l/min
VEI-8A-2T-09-NC-S V096005 350 bar 70 l/min
VEI-8A-2T-12-NC-S V096006 350 bar 150 l/min
1 B
Tipo valvola Tempi di risposta - Response time
Valve type Apertura - Opening Chiusura - Closing
VEI-8A-2T-06-NC-S 30-40 ms 75-110 ms
VEI-8A-2T-09-NC-S 45-60 ms 140-220 ms
VEI-8A-2T-12-NC-S 45-60 ms 180-240 ms

2.52.70
Componenti s.r.l.

VALVOLE ELETTRICHE 2 VIE PILOTATE A DOPPIA TENUTA


2 way pilot operated double lock solenoid valves

VEI-8A-2T-06-NA-S DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code OD.15.32.18.Y.00
VEI-8A-2T-09-NA-S OD.15.32.17.Y.00
VEI-8A-2T-12-NA-S OD.15.32.21.Y.00

Descrizione
Description
Sono valvole ad azionamento elettrico a 2 vie a doppia tenuta pilotate Two way, pilot operated, double lock normally closed poppet style solenoid
normalmente chiuse a cartuccia indicate per applicazioni in cui si richiede cartridge valves, designed for applications requiring virtually zero internal
un trafilamento interno praticamente nullo. leakage.
• Filtrazione : 25 +m nominali o inferiore • Filtration : 25 +m nominal or better
• Minimo Voltaggio Richiesto : 90% del nominale • Minimum Voltage Required : 90% of nominal
• Solenoidi da ordinare separatamente • Coils must be ordered separately

Coppia 3.5(0.5 Nm Coppia 3.5(0.5 Nm Coppia 3.5(0.5 Nm

62.5 60.5
65

Bobina S8
Bobina S8 Bobina S8
ch.38
ch.32 Coppia 90(10 Nm
ch.24 Coppia 60(6 Nm
Coppia 45(6 Nm

2 A 49
2 A 27.5 2 A 38

B
1 1 B 1 B
Ø12.7 e9 Ø23.5 e9 Ø30 e9
3/4”-16UNF-2A
G 3/4 G1

Perdite di carico - Pressure drop Perdite di carico - Pressure drop Perdite di carico - Pressure drop
12 12 18
10 10 15
Pressionz - Pressure Bar

Pressionz - Pressure Bar

Pressionz - Pressure Bar

A A
8 8 o 12 o
rs rs
ve ve
6 6 B 9 B
B B
rso rs
o
4 4 ve 6 ve
A A
2 2 3

0 8 16 24 32 40 48 0 12 24 32 48 60 72 0 24 48 72 96 120 144
Portata - Flow l/min Portata - Flow l/min Portata - Flow l/min

13 19
Opzioni - Options Prodotto Edi System
Y Edi System product
17 Standard
Con emergenza a spinta
33
18 With push emergency PATENTED
19 Con emergenza a spinta e rotazione
With push and spin emergency

Tipo valvola Cavità Pressione max lavoro Portata max


2 A
Valve type Cavity Max working pressure Max flow
VEI-8A-2T-06-NA-S V096004 350 bar 40 l/min
VEI-8A-2T-09-NA-S V096005 350 bar 70 l/min
1 B VEI-8A-2T-12-NA-S V096006 350 bar 150 l/min

2.52.72
Componenti s.r.l.

VALVOLE ELETTRICHE 3 VIE DIRETTA A TENUTA


3 way direct acting poppet style solenoid valves

V3D-DT DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.43.A.Y.0
V3D-DT+S4-CEI 78.896.43.A.Y.0.37.WW.J

Descrizione
Description

Valvole a 3 vie con otturatore conico a tenuta.


La pressione può arrivare da qualsiasi foro della
cavità senza che il funzionamento venga
compromesso:
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.10);

The oil can enter into any of cavity’s holes without


compromising its function:
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features (see on page 2.50.10);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
Symbol Diseccitato Eccitato
De-energized Energized

PCA PCB
B o ><o A o ><o

B o ><o BCP
PCA A o ><o

ACP A o ><o
B o ><o PCB

Tempi di risposta Apertura - Opening Chiusura - Closing


Operating time
20-35 ms 40-60 ms

Pressione max di lavoro Portata max 20 l/min


250 bar
New
Max working pressure Max flow

Solenoidi - Coils
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC Cavità - Cavity
OD 48V dc OW 110V RAC
Y
N$ F

Connettori - Connectors 0 V096002 7/8"-14 UNF


7 V096112 M22x1,5
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector
1 2 3 4

2.53.02
Componenti s.r.l.

VALVOLE ELETTRICHE 3 VIE 2 POSIZIONI DIRETTE A TENUTA


3 way 2 position direct acting poppet style solenoid valves

V3D-CE DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.04.A.0.0
V3D-CE+S-V3D 78.896.04.A.0.0.25.WW.J

Descrizione
Description

Valvole a 3 vie con otturatore conico a tenuta.


La pressione può arrivare da qualsiasi foro della
cavità senza che il funzionamento venga
compromesso:
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.10);

The oil can enter into any of cavity’s holes without


compromising its function:
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features (see on page 2.50.10);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
Symbol Diseccitato Eccitato
De-energized Energized

PCA PCB
B o ><o A o ><o

Tempi di risposta Apertura - Opening Chiusura - Closing


Operating time B o ><o BCP
20-35 ms 40-60 ms PCA A o ><o

Pressione max di lavoro Portata max


Max working pressure 300 bar Max flow 25 l/min ACP A o ><o
B o ><o PCB
Solenoidi - Coils
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc OW 110V RAC
OC 24V dc OZ 220V RAC Cavità - Cavity
OD 48V dc N$ F

Connettori - Connectors V096002 7/8"-14 UNF

Senza Standard Con raddrizzatore


J Without Standard With rectifier
1 2 3

2.53.06
Componenti s.r.l.

VALVOLE ELETTRICHE 3 VIE 2 POSIZIONI A CURSORE


3 way 2 position solenoid valves, spool type

V3DS-2P DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.55.X.Y.0
V3DS-2P+S-CE 78.896.55.X.Y.0.55.WW.J

Descrizione
Description

Valvola a 3 vie 2 posizioni a cassetto di piccole dimensioni


e di accurata lavorazione per montaggio in blocchi
integrati di elevata compattezza.
• Trafilamento interno max: 60 cm3/min a 210 bar con
olio 46 CSt a 20$C
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

3 way 2 position valve, spool type on very small


dimensions very useful for small integrated blocks.
• Max Internal leakage: 60 cc/min at 210 bar with
46 cSt oil at 20$C.
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PAA PAB
A B o> A o>

PAA PAB
E B o> A o>

P o> PCB
B ACB A o>

P o> PCB
G ACB A o>

Pressione max di lavoro Portata max


Max working pressure 210 bar Max flow 8 l/min PCB P o>
C
A o> ACB
Solenoidi - Coils
Tensione Tensione Tensione PCB P o>
WW Voltage WW Voltage WW Voltage M
A o> ACB
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC
Cavità - Cavity
Connettori - Connectors Y
N$ F
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector 0 V096057 3/4"-16 UNF
1 2 3 4 7 V096109 M18x1,5

2.53.10
Componenti s.r.l.

VALVOLE ELETTRICHE 3 VIE 2 POSIZIONI A CURSORE


3 way 2 position solenoid valves, spool type

V3DS4-2P DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.58.X.0.0
V3DS4-2P+S4-CEI 78.896.58.X.0.0.37.WW.J

Descrizione
Description

Valvola a 3 vie 2 posizioni a cassetto di piccole dimensioni


e di accurata lavorazione per montaggio in blocchi
integrati di elevata compattezza.
• Trafilamento interno max: 80 cm3/min a 210 bar con
olio 46 CSt a 20$C
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.10);

3 way 2 position valve, spool type on very small


dimensions very useful for small integrated blocks.
• Max Internal leakage: 80 cc/min at 210 bar with
46 cSt oil at 20$C.
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.10);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PAA PAB
A B o> A o>

PAA PAB
E B o> A o>

P o> PCB
B ACB A o>

P o> PCB
G ACB A o>

Pressione max di lavoro Portata max


Max working pressure 210 bar Max flow 20 l/min
PCB P o>
C
A o> ACB
Solenoidi - Coils
Tensione Tensione Tensione PCB P o>
WW Voltage WW Voltage WW Voltage M
A o> ACB
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC
Cavità - Cavity
Connettori - Connectors Y
N$ F
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector V096002 7/8"-14 UNF
1 2 3 4

2.53.14
Componenti s.r.l.

VALVOLE ELETTRICHE 3 VIE 2 POSIZIONI A CURSORE


3 way 2 position solenoid valve, spool type

V3D-CEI-2P DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.37.X.1.0
V3D-CEI-2P+S4-CEI 78.896.37.X.1.0.37.WW.J

Descrizione
Description

Valvola a 3 vie 2 posizioni a cassetto di piccole dimensioni


e di accurata lavorazione per montaggio in blocchi
integrati di elevata compattezza.
• Trafilamento interno max: 80 cm3/min a 210 bar con
olio 46 CSt a 20$C
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.10);

3 way 2 position valve, spool type on very small


dimensions very useful for small integrated blocks.
• Max Internal leakage: 80 cc/min at 210 bar with
46 cSt oil at 20$C.
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.10);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

Po> PAC
A CAT T o>

Pressione max di lavoro Portata max


Max working pressure 210 bar Max flow 20 l/min

Solenoidi - Coils
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC
Cavità - Cavity
Connettori - Connectors Y
N$ F
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector V096002 7/8"-14 UNF
1 2 3 4

2.53.16
Componenti s.r.l.

VALVOLE ELETTRICHE 4 VIE 2 POSIZIONI A CURSORE


4 way 2 position solenoid valves, spool type

V4DS-2P DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.56.X.Y.0
V4DS-2P+S-CE 79.896.56.X.Y.0.55.WW.J

Descrizione
Description

Valvola a 4 vie 2 posizioni a cassetto di piccole dimensioni


e di accurata lavorazione per montaggio in blocchi
integrati di elevata compattezza.
• Trafilamento interno max: 60 cm3/min a 210 bar con
olio 46 CSt a 20$C
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

4 way 2 position valve, spool type on very small


dimensions very useful for small integrated blocks.
• Max Internal leakage: 60 cc/min at 210 bar with
46 cSt oil at 20$C.
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PCA PCB
A BCT ACT

PCA PCB
E BCT ACT

P P
A o ><o A PCB
B B B ACT
T T
P P
A o ><o A PCB
G B B ACT
T T
Pressione max di lavoro Portata max
Max working pressure 210 bar Max flow 8 l/min

Solenoidi - Coils
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC
Cavità - Cavity
Connettori - Connectors Y
N$ F
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector 0 V096032 3/4"-16 UNF
1 2 3 4 8 V096110 M18x1,5

2.54.02
Componenti s.r.l.

VALVOLE ELETTRICHE 4 VIE 2 POSIZIONI A CURSORE


4 way 2 position solenoid valves, spool type

V4DS4-2P DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.63.X.Y.Z
V4DS4-2P+S4-CEI 79.896.63.X.Y.Z.37.WW.J

Descrizione
Description

Valvola a 4 vie 2 posizioni a cassetto di piccole dimensioni


e di accurata lavorazione per montaggio in blocchi
integrati di elevata compattezza.
• Trafilamento interno max: 80 cm3/min a 210 bar con
olio 46 CSt a 20$C
• Filtrazione 25 micron nominali o inferiore;
• Caratteristiche solenoide
(vedi pag. 2.50.10);

4 way 2 position valve, spool type on very small


dimensions very useful for small integrated blocks.
• Max Internal leakage: 80 cc/min at 210 bar with
46 cSt oil at 20$C.
• Filtration level: 25 micron or better;
• Coils features
(see on page 2.50.10);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PCA PCB
A BCT ACT

PCA PCB
E BCT ACT

P P
A o ><o A PCB
B ACT
B B
T T
P P
A o ><o A PCB
G ACT
B B
T T
Cavità - Cavity
Z PCT PCB
N$ F F A o> ACT
0 V096074 7/8"-14 UNF B o>

8 V096113 M22x1,5
Pressione max di lavoro Vedi diagramma Portata max 25 l/min
Max working pressure See diagram Max flow

Solenoidi - Coils
Y Filtri - Filter
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc OV 24V RAC OZ 220V RAC 1
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC
2
Connettori - Connectors
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector 3
1 2 3 4

2.54.04
Componenti s.r.l.

VALVOLE ELETTRICHE 4 VIE 2 POSIZIONI A CURSORE


4 way 2 position solenoid valves, spool type

V4D-CEI-2P DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.31.X.Y.0
V4D-CEI-2P+S4-CEI 79.896.31.X.Y.0.37.WW.J

Descrizione
Description

Valvola a 4 vie 2 posizioni a cassetto di piccole dimensioni


e di accurata lavorazione per montaggio in blocchi
integrati di elevata compattezza.
• Trafilamento interno max: 80 cm3/min a 210 bar con
olio 46 CSt a 20$C
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.10);

4 way 2 position valve, spool type on very small


dimensions very useful for small integrated blocks.
• Max Internal leakage: 80 cc/min at 210 bar with
46 cSt oil at 20$C.
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.10);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PCB PCA
A ACT BCT

PCA PCT
D BCT A o>
B o>

Y Filtri - Filter

Pressione max di lavoro Vedi diagramma Portata max


Max working pressure See diagram Max flow 25 l/min
2
Solenoidi - Coils
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage 3
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC
Cavità - Cavity
Connettori - Connectors
N$ F
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector V096074 7/8"-14 UNF
1 2 3 4

2.54.06
Componenti s.r.l.

VALVOLE ELETTRICHE 4 VIE 3 POSIZIONI A CURSORE


4 way 3 position solenoid valves, spool type

V4DS-3P DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.57.X.Y.0
V4DS-3P+S-CE 79.896.57.X.Y.0.55.WW.J

Descrizione
Description

Valvola a 4 vie 3 posizioni a cassetto di piccole dimensioni


e di accurata lavorazione per montaggio in blocchi
integrati di elevata compattezza.
• Trafilamento interno max: 60 cm3/min a 210 bar con
olio 46 CSt a 20$C
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06);

4 way 3 position valve, spool type on very small


dimensions very useful for small integrated blocks.
• Max Internal leakage: 60 cc/min at 210 bar with
46 cSt oil at 20$C.
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Eccitato A Diseccitato Eccitato B
Energized A De-energized Energized B
P P
PAB A o ><o A PAA
A AAT B B BAT
T T

PAB AAT
PAA
B AAT BAT
BAT
P o>

P P
PAB A C A PAA
C AAT B B BAT
T T

PAB P o>
D PAA
AAT B o>
BAT
AAT
Pressione max di lavoro Portata max
Max working pressure 210 bar Max flow 8 l/min

Solenoidi - Coils
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc OV 24V RAC OZ 220V RAC
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC
Cavità - Cavity
Connettori - Connectors Y
N$ F
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector 0 V096032 3/4"-16 UNF
1 2 3 4 8 V096110 M18x1,5

2.54.16
Componenti s.r.l.

VALVOLE ELETTRICHE 4 VIE 3 POSIZIONI A CURSORE


4 way 3 position solenoid valve, spool type

V4D-CEI-3P DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.896.33.X.Y.Z
V4D-CEI-3P+S4-CEI 79.896.33.X.Y.Z.37.WW.J

Descrizione
Description

Valvola a 4 vie 3 posizioni a cassetto di piccole dimensioni


e di accurata lavorazione per montaggio in blocchi
integrati di elevata compattezza.
• Trafilamento interno max: 80 cm3/min a 210 bar con
olio 46 CSt a 20$C
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.10);

4 way 3 position valve, spool type on very small


dimensions very useful for small integrated blocks.
• Max Internal leakage: 80 cc/min at 210 bar with
46 cSt oil at 20$C.
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.10);

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Eccitato A Diseccitato Eccitato B
Energized A De-energized Energized B
P P
PAB A o ><o A PAA
A AAT B B BAT
T T

PAB AAT
PAA
B AAT BAT
BAT
P o>

A o>
PAB PAA
C AAT
B o>
BAT
PAT
Cavità - Cavity
Z P o>
N$ F PAB PAA
E AAT B o>
0 BAT
V096074 7/8"-14 UNF AAT
8 V096113 M22x1,5

Pressione max di lavoro Vedi diagramma Portata max 25 l/min


Max working pressure See diagram Max flow
Filtri - Filter
Solenoidi - Coils Y 300 micron
Tensione Tensione Tensione
WW Voltage WW Voltage WW Voltage
OB 12V dc OV 24V RAC OZ 220V RAC 1
OC 24V dc OK 48V RAC
OD 48V dc OW 110V RAC
2
Connettori - Connectors
Senza Standard Con raddrizzatore Attacco Kostal
J Without Standard With rectifier Kostal connector 3
1 2 3 4

2.54.24
Componenti s.r.l.

VALVOLE ELETTRICHE PER COMANDO CILINDRO A SEMPLICE EFFETTO


Solenoid valve for single acting cylinder

CE6-VM-VU-ST DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.880.06.X.Y.Z

Descrizione
Description

Circuiti integrati per impianti con cilindro S.E.: con un


pulsante si comanda l’avviamento del motore elettrico
ed il conseguente sollevamento del carico; con un
secondo pulsante, eccitando il solenoide, si ottiene la
discesa del carico alla velocità prestabilita. Con motore
fermo e solenoide diseccitato si ha la sicurezza di una
perfetta tenuta. La valvola di controllo pressione è in
grado di evitare picchi di pressione indesiderati.
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06)

These blocks are typically used in hydraulic lifts with


single acting cylinder. Whit the NC solenoid valve the
load lifting is obtained by starting the pump and the
lowering by energizing the solenoid valve; when the
pump and the solenoid valve are off, the perfect load-
holding is ensured.
The relief valve avoid undesired pick pressure.
Solenoidi: “S-CE” (da ordinare separatamente) • Internal leakage: virtually zero
Coils: “S-CE” (to be ordered separately) (see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06)

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PAC
A CAT
Co>T

Pressione max di lavoro 300 bar Portata max 25 l/min


Max working pressure Max flow PAT
Co>T
B CAT

Molle - Springs
Campo di taratura Taratura standard Codice di Colore
Z Pressure range Standard setting ordinazione Colour
(bar) (bar) Ordering code Attacchi - Ports size
Y
2 30 – 100 100 (at 5 l/min) Blu / Blue P-T-C
3 50 – 210 200 (at 5 l/min) Verde / Green 1 1/4”BSPP
4 100 – 350 350 (at 5 l/min) Giallo / Yellow 2 3/8”BSPP
3 1/2”BSPP

2.56.02
Componenti s.r.l.

VALVOLE ELETTRICHE PER COMANDO CILINDRO A SEMPLICE EFFETTO


Solenoid valve for single acting cylinder

CE1-VM-VU-STF14 DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.880.40.X.Y.Z

Descrizione
Description

Circuiti integrati per impianti con cilindro S.E.: con un


pulsante si comanda l’avviamento del motore elettrico
ed il conseguente sollevamento del carico; con un
secondo pulsante, eccitando il solenoide, si ottiene la
discesa del carico alla velocità prestabilita. Con motore
fermo e solenoide diseccitato si ha la sicurezza di una
perfetta tenuta. La valvola di controllo pressione è in
grado di evitare picchi di pressione indesiderati.
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06)

These blocks are typically used in hydraulic lifts with


single acting cylinder. Whit the NC solenoid valve the
load lifting is obtained by starting the pump and the
lowering by energizing the solenoid valve; when the
pump and the solenoid valve are off, the perfect load-
holding is ensured.
The relief valve avoid undesired pick pressure.
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
Solenoidi: “S-CE” (da ordinare separatamente) • Minimum operating voltage: 90% of nominal;
Coils: “S-CE” (to be ordered separately) • Coils features
(see on page 2.50.06)

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

PAC
A CAT
Co>T

PAT
Co>T
B CAT
Pressione max di lavoro 250 bar Portata max 10 l/min
Max working pressure Max flow

Molle - Springs Portata regolata STF14


Campo di taratura Taratura standard Codice di Colore
Z STF14 regulated flow
Y Pressure range Standard setting ordinazione Colour
Codice Codice
(bar) (bar) Ordering code l/min ((10%) l/min ((10%)
Code Code
1 5 – 50 30 (at 5 l/min) Nero / Black 0 Senza / without E 5
2 30 – 120 80 (at 5 l/min) Blu / Blue A 1 F 6
3 80 – 250 150 (at 5 l/min) Verde / Green B 2 G 7
C 3 H 8
D 4 L 10

2.56.04
Componenti s.r.l.

VALVOLE DI MASSIMA CON BY-PASS A COMANDO ELETTRICO


Relief valve with solenoid operated by-pass

CE6-VM25 DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.880.09.X.Y.Z

Descrizione
Description

Modulo integrato impiegato in circuiti ove si richieda


controllo della pressione di funzionamento e possibilità
di mettere a scarico la portata mediante un by-pass a
comando elettrico.
• Elemento controllo pressione ad otturatore conico
guidato tipo VM25;
• Trafilamento interno virtualmente nullo
(vedi pag. 9.50.08);
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06)

These blocks can be used in circuits where relief


protection and solenoid operated by-pass features are
required.
• Pressure control poppet style;
• Internal leakage: virtually zero
(see on page 9.50.08);
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06)

Solenoidi: “S-CE” (da ordinare separatamente)


Coils: “S-CE” (to be ordered separately)

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

A Po>T PAT

Pressione max di lavoro 300 bar Portata max 25 l/min


Max working pressure Max flow

Molle - Springs B PAT Po>T

Campo di taratura Taratura standard Codice di Colore


Z Pressure range Standard setting ordinazione Colour
(bar) (bar) Ordering code

1 5 – 100 50 (at 5 l/min) Nero / Black


2 40 – 200 100 (at 5 l/min) Blu / Blue Attacchi - Port size
Y
3 70 – 350 200 (at 5 l/min) Verde / Green P-T
2 3/8”BSPP
3 1/2”BSPP

2.56.06
Componenti s.r.l.

VALVOLE DI MASSIMA PILOTATA ELETTRICAMENTE


Ventable pilot operated relief valve

VM15-CE DENOMINAZIONE VALVOLA


Valve denomination
CODICE ORDINAZIONE
Ordering code V3.880.14 .X.Y.Z

Descrizione
Description

Modulo integrato impiegato in circuiti ove si richieda


controllo della pressione di funzionamento e possibilità
di mettere a scarico la portata mediante un by-pass a
comando elettrico.
• Trafilamento: 0.1 L/min alla max pressione;
• Filtrazione 25 micron nominali o inferiore;
• Voltaggio minimo richiesto: 90% del nominale;
• Caratteristiche solenoide
(vedi pag. 2.50.06)

These blocks can be used in circuits where relief


protection and solenoid operated by-pass features are
required.
• Internal leakage: 0.1 L/min at the maximum pressure
• Filtration level: 25 micron or better;
• Minimum operating voltage: 90% of nominal;
• Coils features
(see on page 2.50.06)

Solenoidi: “S-CE” (da ordinare separatamente)


Coils: “S-CE” (to be ordered separately)

Funzioni possibili con solenoide:


Schema Operating features with solenoid:
X Symbol Diseccitato Eccitato
De-energized Energized

A Po>T PAT

Pressione max di lavoro 250 bar Portata max 150 l/min


Max working pressure Max flow

Molle - Springs B PAT Po>T

Campo di taratura Taratura standard Codice di Colore


Z Pressure range Standard setting ordinazione Colour
(bar) (bar) Ordering code

1 5 – 50 30 (at 5 l/min) Nero / Black


2 30 – 120 80 (at 5 l/min) Blu / Blue Attacchi - Port size
Y
3 80 – 250 150 (at 5 l/min) Verde / Green P-T
4 3/4”BSPP
5 1”BSPP

2.56.08
Componenti s.r.l.

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.857.XX.000
Cavita'
Cavity Descrizione

13
Description
Ø
6.5
P Linea di collettori in alluminio estruso AL 2011 UNI9002/5
per il montaggio in cavità unificate di tutta la nostra
50 gamma di valvole.

Manifold obtained from extruded aluminium AL 2011


UNI9002/5 for assembling all our valves on unified cavity.
22

20 A
6 38 6 30 Pressione max di lavoro
50 Max working pressure 300 bar

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N$ Peso Kg.
xx Port size P-A Cavity N$ Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 6 . 7 . X X . Y Y. Y Y Y. W W. W W W
32 Codice blocco
1/4" BSPP Manifold code
V096001
11 3/8" BSPP Codice valvola (ultime 5 cifre)
0.16 Valve code (last 5 numbers)
45 1/4" BSPP
V096004 Codice solenoide (ultime 5 cifre)
40 3/8" BSPP Coil code (last 5 numbers)

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.855.XX.000
Cavita'
Cavity
Descrizione
12.5

Description
Emergency screw

Ø
Vite emergenza

6.5
P

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


per il montaggio in cavità unificate di tutta la nostra
gamma di valvole.
50

Manifold obtained from extruded aluminium AL 2011


UNI9002/5 for assembling all our valves on unified cavity.
23.5

17 A
6 38 6 ch.5 30
Pressione max di lavoro 300 bar
50 12 es.ch.17 Max working pressure

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N$ Peso Kg.
xx Port size P-A Cavity N$ Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 6 . 5 . X X . Y Y. Y Y Y. W W. W W W
74 Codice blocco
1/4" BSPP Manifold code
V096001
75 3/8" BSPP Codice valvola (ultime 5 cifre)
0.18 Valve code (last 5 numbers)
76 1/4" BSPP
V096004 Codice solenoide (ultime 5 cifre)
77 3/8" BSPP Coil code (last 5 numbers)

7.50.02
Componenti s.r.l.

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.857.XX.000
Cavita'
Cavity
Descrizione

13
Description

P Linea di collettori in alluminio estruso AL 2011 UNI9002/5


per il montaggio in cavità unificate di tutta la nostra
gamma di valvole.
Ø 6.5 50
Manifold obtained from extruded aluminium AL 2011
22

UNI9002/5 for assembling all our valves on unified cavity.

16 A
6

31 19 30
44 6 Pressione max di lavoro
Max working pressure 300 bar
50

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N$ Peso Kg.
xx Port size P-A Cavity N$ Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 6 . 7 . X X . Y Y. Y Y Y. W W. W W W
Codice blocco
62 Manifold code
1/4" BSPP
Codice valvola (ultime 5 cifre)
V096004 0.16 Valve code (last 5 numbers)
63 3/8" BSPP Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.857.XX.000

Cavita'
Cavity Ø 6.5 Descrizione
Emergency screw

Description
Vite emergenza

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


P

per il montaggio in cavità unificate di tutta la nostra


gamma di valvole.
50

Manifold obtained from extruded aluminium AL 2011


36.5

UNI9002/5 for assembling all our valves on unified cavity.


6
22
19

ch.5 6 A
19 30 Pressione max di lavoro 300 bar
es.ch.17
34 Max working pressure
65

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N$ Peso Kg.
xx Port size P-A Cavity N$ Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 6 . 7 . X X . Y Y. Y Y Y. W W. W W W
Codice blocco
64 Manifold code
1/4" BSPP
Codice valvola (ultime 5 cifre)
V096004 0.25 Valve code (last 5 numbers)
65 3/8" BSPP Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

7.50.03
Componenti s.r.l.

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.857.XX.000
Ø
5.5 Cavita'
Cavity Descrizione
Description

Linea di collettori in alluminio estruso AL 2011 UNI9002/5

14
P
per il montaggio in cavità unificate di tutta la nostra
gamma di valvole.
50
45

Manifold obtained from extruded aluminium AL 2011


UNI9002/5 for assembling all our valves on unified cavity.
5

5 A
22 40 Pressione max di lavoro
Max working pressure 300 bar
45
50

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N$ Peso Kg.
xx Port size P-A Cavity N$ Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 6 . 7 . X X . Y Y. Y Y Y. W W. W W W
46 Codice blocco
1/4" BSPP Manifold code
47 3/8" BSPP Codice valvola (ultime 5 cifre)
V096004 0.20 Valve code (last 5 numbers)
48 1/2" BSPP
Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.857.XX.000

Cavita'
Cavity Descrizione
Description
15

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


P

per il montaggio in cavità unificate di tutta la nostra


gamma di valvole.
50

Manifold obtained from extruded aluminium AL 2011


.5
Ø6 UNI9002/5 for assembling all our valves on unified cavity.
15

30 A
7.5 45 7.5 30 Pressione max di lavoro 300 bar
60 Max working pressure

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N$ Peso Kg.
xx Port size P-A Cavity N$ Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 6 . 7 . X X . Y Y. Y Y Y. W W. W W W
Codice blocco
50 Manifold code
1/4" BSPP
Codice valvola (ultime 5 cifre)
V096004 0.21 Valve code (last 5 numbers)
51 3/8" BSPP Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

7.50.04
Componenti s.r.l.

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

L
Cavita' CODICE ORDINAZIONE
Ordering code V3.880.02.0XX
Cavity G I

Emergency screw
Vite emergenza
Descrizione
E
F
Description

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


ch. per il montaggio in cavità unificate di tutta la nostra
FIL.P gamma di valvole.

Manifold obtained from extruded aluminium AL 2011


ch.5
FIL.A UNI9002/5 for assembling all our valves on unified cavity.
A
H
B es.ch.17
C D

15 36.5 50 11 17 50 13.5 30 7.5 51 22 3/8”BSPP Pressione max di lavoro


Max working pressure 300 bar
16 39 55 9 18 60 12.5 35 9.5 57 30 1/2”BSPP
A B C D E F G H I L Ch. Fil.A-Fil.P

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N° Peso Kg.
xx Port size P-A Cavity N° Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 7 . 2 . X X . Y Y. Y Y Y. W W. W W W
Codice blocco
20 Manifold code
3/8" BSPP 0.40
Codice valvola (ultime 5 cifre)
V096001 Valve code (last 5 numbers)
30 1/2" BSPP 0.53 Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

L
Cavita'
G I
CODICE ORDINAZIONE
Ordering code V3.880.04.0XX
Cavity

Descrizione
E

Description
F

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


ch. per il montaggio in cavità unificate di tutta la nostra
FIL.P

gamma di valvole.

Manifold obtained from extruded aluminium AL 2011


FIL.A UNI9002/5 for assembling all our valves on unified cavity.
A
H
B
C

15 33.5 45 22 50 12 30 7.5 49.5 19 1/4”BSPP Pressione max di lavoro 300 bar


15 36.5 50 22 50 13.5 30 7.5 51 22 3/8”BSPP
Max working pressure
A B C E F G H I L Ch. Fil.A-Fil.P

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N° Peso Kg.
xx Port size P-A Cavity N° Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 7 . 4 . X X . Y Y. Y Y Y. W W. W W W
Codice blocco
10 0.34 Manifold code
1/4" BSPP
Codice valvola (ultime 5 cifre)
V096001 Valve code (last 5 numbers)
20 3/8" BSPP 0.36 Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

7.50.06
Componenti s.r.l.

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

CODICE ORDINAZIONE
Ordering code V3.880.43.0XX

Cavita' 51
Descrizione
Cavity 13.5 7.5
Description

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


17

P per il montaggio in cavità unificate di tutta la nostra


gamma di valvole.
41

Manifold obtained from extruded aluminium AL 2011


55

ch.22 UNI9002/5 for assembling all our valves on unified cavity.


3/8"BSPP

Pressione max di lavoro


15 300 bar
3/8"BSPP

30 Max working pressure


36.5
50
COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 7 . 3 . X X . Y Y. Y Y Y. W W. W W W
Attacchi P-A Cavità N° Peso Kg. Codice blocco
xx Port size P-A Cavity N° Weight Kg. Manifold code
Codice valvola (ultime 5 cifre)
Valve code (last 5 numbers)
20 3/8" BSPP V096001 0.38 Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

CODICE ORDINAZIONE
Ordering code V3.880.42.0XX

Cavita' 51 Descrizione
Cavity 13.5 7.5 Description

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


per il montaggio in cavità unificate di tutta la nostra
17

P gamma di valvole.
41

Manifold obtained from extruded aluminium AL 2011


55

UNI9002/5 for assembling all our valves on unified cavity.


ch.22
3/8"BSPP

A
Pressione max di lavoro 300 bar
13.5 Max working pressure
30
3/8"BSPP

35
50
COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 7 . 1 . X X . Y Y. Y Y Y. W W. W W W
Attacchi P-A Cavità N° Peso Kg. Codice blocco
xx Port size P-A Cavity N° Weight Kg. Manifold code
Codice valvola (ultime 5 cifre)
Valve code (last 5 numbers)
20 3/8" BSPP V096001 0.38 Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

7.50.08
Componenti s.r.l.

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

Blocco+SBF38-10 (1-10 l/min) CODICE ORDINAZIONE


Ordering code V3.880.05.01X
Blocco+SBF38-20 (11-20 l/min) V3.880.05.02Z

Cavita'V096004 42.5
Cavity V096004 11.5 25 6

8.3

P
50

ch.25
33

3/8"BSPP Torque 45 Nm

A
15 3/8"BSPP

35.5
Descrizione
50 Description

Collettore in acciaio zincato giallo flangiabile su cilindro


SCHEMA IDRAULICO
con valvola controllo discesa a taratura fissa incorporata.
P
Steel manifold coated with zinc plating strengthened by
yellow passivation flangeable on cylinders with fixed
SBF38 flow control valve compensated.

Pressione max di lavoro


Max working pressure 350 bar
CE
CODICE BLOCCO+SBF38-10+VALVOLA+SOLENOIDE
A ORDERING CODE FOR MANIFOLD+SBF38-10+VALVE+COIL

9 5 . 5 . 1 X . Y Y. Y Y Y. W W . W W W
Codice blocco
Manifold code
X A B C D E F G H I L Codice valvola (ultime 5 cifre)
Valve code (last 5 numbers)
Portata Codice solenoide (ultime 5 cifre)
L/min 1 2 3 4 5 6 7 8 9 10 Coil code (last 5 numbers)
Foro # 1.1 1.1 1.5 1.7 1.9 2.1 2.3 2.5 2.7 2.9
CODICE BLOCCO+SBF38-20+VALVOLA+SOLENOIDE
ORDERING CODE FOR MANIFOLD+SBF38-20+VALVE+COIL

Z M N O P Q R T Z 9 5 . 5 . 2 Z . Y Y. Y Y Y. W W . W W W
Codice blocco
Manifold code
Portata Codice valvola (ultime 5 cifre)
L/min 11 12 13 14 15 16 18 20 Valve code (last 5 numbers)
Codice solenoide (ultime 5 cifre)
Foro # 2.5 2.6 2.7 2.8 2.9 3.0 3.3 3.4 Coil code (last 5 numbers)

7.50.10
Componenti s.r.l.

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.855.XX.000

Cavita'
Descrizione

6.5
Cavity

Ø
Description
es.ch.17

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


per il montaggio in cavità unificate di tutta la nostra
ch.5

P
gamma di valvole.

65
59
Manifold obtained from extruded aluminium AL 2011
40

UNI9002/5 for assembling all our valves on unified cavity.


23

8.5 39 A
6

74
40 Pressione max di lavoro
80
Max working pressure 250 bar

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N° Peso Kg.
xx Port size P-A Cavity N° Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 6 . 5 . X X . Y Y. Y Y Y. W W. W W W
Codice blocco
78 Manifold code
1/2" BSPP
Codice valvola (ultime 5 cifre)
V096005 0.46 Valve code (last 5 numbers)
79 3/4" BSPP Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA


Aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.855.XX.000
Cavita'
8.5

Cavity
Ø

Descrizione
Description
es.ch.17

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


P
ch.5

per il montaggio in cavità unificate di tutta la nostra


gamma di valvole.
80
72.5

Manifold obtained from extruded aluminium AL 2011


48.5

UNI9002/5 for assembling all our valves on unified cavity.


29

A
7.5

8.5 43
50
Pressione max di lavoro 250 bar
82.5 Max working pressure
90

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N° Peso Kg.
xx Port size P-A Cavity N° Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 6 . 5 . X X . Y Y. Y Y Y. W W. W W W
Codice blocco
94 Manifold code
3/4" BSPP
Codice valvola (ultime 5 cifre)
V096006 0.82 Valve code (last 5 numbers)
80 1" BSPP Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

7.50.12
Componenti s.r.l.

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA 3 VIE


3 way aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.856.XX.000

Cavita' Descrizione
Ø 6.5 Cavity Description

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


per il montaggio in cavità unificate di tutta la nostra
A gamma di valvole.
60

Manifold obtained from extruded aluminium AL 2011


52

45.5
UNI9002/5 for assembling all our valves on unified cavity.
31

8 B 30 Pressione max di lavoro


30 Max working pressure 250 bar
52
60
COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 2 . 6 . X X . Y Y. Y Y Y. W W. W W W
Attacchi P-A Cavità N° Peso Kg. Codice blocco
xx Port size P-A Cavity N° Weight Kg. Manifold code
Codice valvola (ultime 5 cifre)
Valve code (last 5 numbers)
25 1/4" BSPP V096057 0.26 Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA 3 VIE


3 way aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.856.XX.000
Cavita'
Ø 6.5
Cavity Descrizione
Description
B

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


per il montaggio in cavità unificate di tutta la nostra
P

gamma di valvole.
75
65
57.5

Manifold obtained from extruded aluminium AL 2011


41

UNI9002/5 for assembling all our valves on unified cavity.


25

A Pressione max di lavoro 250 bar


L1 40 L1
S
Max working pressure
L

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N° Peso Kg.
xx Port size P-A Cavity N° Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 2 . 6 . X X . Y Y. Y Y Y. W W. W W W
Codice blocco
23 Manifold code
3/8" BSPP 0.31
Codice valvola (ultime 5 cifre)
V096002 Valve code (last 5 numbers)
24 1/2" BSPP 0.38 Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

7.50.14
Componenti s.r.l.

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA 4 VIE


4 way aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.856.XX.000
Cavita'
Ø 6.5 Cavity
Descrizione
Description

14.5
B
Linea di collettori in alluminio estruso AL 2011 UNI9002/5

29
P

per il montaggio in cavità unificate di tutta la nostra


gamma di valvole.
76

A
68

Manifold obtained from extruded aluminium AL 2011


UNI9002/5 for assembling all our valves on unified cavity.
46.5

Pressione max di lavoro


8 T 30
Max working pressure 250 bar
30
52
60
COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 3 . 6 . X X . Y Y. Y Y Y. W W. W W W
Attacchi P-A Cavità N° Peso Kg. Codice blocco
xx Port size P-A Cavity N° Weight Kg. Manifold code
Codice valvola (ultime 5 cifre)
Valve code (last 5 numbers)
26 1/4" BSPP V096032 0.32 Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

COLLETTORI IN ALLUMINIO PER VALVOLE A CARTUCCIA 4 VIE


4 way aluminium manifolds

CODICE ORDINAZIONE
Ordering code B3.857.XX.000
Cavita'
Cavity
Descrizione
A Description

Linea di collettori in alluminio estruso AL 2011 UNI9002/5


P
per il montaggio in cavità unificate di tutta la nostra
31.5

gamma di valvole.
85

Manifold obtained from extruded aluminium AL 2011


Ø 6.5

B
50.5

UNI9002/5 for assembling all our valves on unified cavity.


35
15

T
Pressione max di lavoro 250 bar
L1 45 L1
35 Max working pressure
L

COMPOSIZIONE CODICE BLOCCO+VALVOLA+SOLENOIDE


Attacchi P-A Cavità N° Peso Kg.
xx Port size P-A Cavity N° Weight Kg.
ORDERING CODE FOR MANIFOLD+VALVE+COIL

9 3 . 7 . X X . Y Y. Y Y Y. W W. W W W
Codice blocco
02 Manifold code
3/8" BSPP 0.33
Codice valvola (ultime 5 cifre)
V096074 Valve code (last 5 numbers)
03 1/2" BSPP 0.45 Codice solenoide (ultime 5 cifre)
Coil code (last 5 numbers)

7.50.16
Componenti s.r.l.

CAVITÀ STANDARD
Standard cavity TABELLA TECNICA
Technical data

CAV. V096004 CAV. V096001

Utensile - Type of tool Codice - Code 0.05 Utensile - Type of tool Codice - Code 0.05
Sgrossatore - Rougher TPU004 Sgrossatore - Rougher TPU001
Finitore - Finisher TAL004 0.025 Finitore - Finisher TAL001 0.025

CAV. V096057 CAV. V096032

Utensile - Type of tool Codice - Code 0.05 Utensile - Type of tool Codice - Code 0.05
Sgrossatore - Rougher TPU057 Sgrossatore - Rougher TPU032
Finitore - Finisher TAL057 0.025 Finitore - Finisher TAL032 0.025

8.50.02
Componenti s.r.l.

CAVITÀ STANDARD
Standard cavity TABELLA TECNICA
Technical data

CAV. V096077

Utensile - Type of tool Codice - Code 0.05


Sgrossatore - Rougher TPU077
Finitore - Finisher TAL077 0.025

CAV. V096002 CAV. V096074

Utensile - Type of tool Codice - Code 0.05 Utensile - Type of tool Codice - Code 0.05
Sgrossatore - Rougher TPU002 Sgrossatore - Rougher TPU074
Finitore - Finisher TAL002 0.025 Finitore - Finisher TAL074 0.025

8.50.04
Componenti s.r.l.

CAVITÀ STANDARD
Standard cavity TABELLA TECNICA
Technical data

CAV. V096005 CAV. V096006

Utensile - Type of tool Codice - Code 0.05 Utensile - Type of tool Codice - Code 0.05
Sgrossatore - Rougher TPU005 Sgrossatore - Rougher TPU006
Finitore - Finisher TAL005 0.025 Finitore - Finisher TAL006 0.025

8.50.06
Componenti s.r.l.

CAVITÀ INTERCAMBIABILI CON ALTRI COSTRUTTORI


Other brands interchangeable cavity TABELLA TECNICA
Technical data

CAV. V096108 (NCS04/2 COMATROL) CAV. V096069 (M20X1.5 FLUTEC)

Utensile - Type of tool Codice - Code 0.05 Utensile - Type of tool Codice - Code 0.05
Sgrossatore - Rougher Sgrossatore - Rougher
Finitore - Finisher 0.025 Finitore - Finisher 0.025

CAV. V096109 (NCS04/3 COMATROL) CAV. V096110 (NCS04/4 COMATROL)

Utensile - Type of tool Codice - Code 0.05 Utensile - Type of tool Codice - Code 0.05
Sgrossatore - Rougher Sgrossatore - Rougher
Finitore - Finisher 0.025 Finitore - Finisher 0.025

8.50.10
Componenti s.r.l.

&$9,7­,17(5&$0%,$%,/,&21$/75,&267587725,
Other brands interchangeable cavity TABELLA TECNICA
Technical data

&$99(NCS06/2 COMATROL)

Utensile - Type of tool Codice - Code 0.05


Sgrossatore - Rougher
Finitore - Finisher 0.025

&$99(NCS06/3 COMATROL) &$99(NCS06/4 COMATROL)

Utensile - Type of tool Codice - Code 0.05 Utensile - Type of tool Codice - Code 0.05
Sgrossatore - Rougher Sgrossatore - Rougher
Finitore - Finisher 0.025 Finitore - Finisher 0.025

8.50.12
Componenti s.r.l.

&$9,7­,17(5&$0%,$%,/,&21$/75,&267587725,
Other brands interchangeable cavity TABELLA TECNICA
Technical data

&$99(VC12-2 HYDRAFORCE) &$99(VC16-2 HYDRAFORCE)

Utensile - Type of tool Codice - Code 0.05 Utensile - Type of tool Codice - Code 0.05
Sgrossatore - Rougher Sgrossatore - Rougher
Finitore - Finisher 0.025 Finitore - Finisher 0.025

8.50.14
Componenti s.r.l.

%2%,1(3(56(59,=,2&217,182²('
Continuous duty coils – ED 100% DATI TECNICI
Technical information

,QWHUPLWWHQ]DGLIXQ]LRQDPHQWR',19'( Working duty DIN VDE 0580

L’intermittenza di funzionamento ED di un elettromagnete è il The working duty ED of a coil is the ratio between energized time
valore percentuale del tempo di inserzione “ti” rispetto al tempo ti and full cycle time tc where tc = ti + tr and tr = de-energized
completo di funzionamento “tc” dove tc = ti + tr dove “tr” è il tempo time.
di riposo.

ED = (ti / tc) * 100% ED = ( ti / tc ) * 100 %

TUTTE LE BOBINE FUNZIONANO CON ED = 100% PURCHÉ ALL COILS ARE RATED FOR ED = 100 % PROVIDED THAT
NON VENGA SUPERATO IL VALORE LIMITE DI TEMPERATURA TEMPERATURE LIMIT OF THEIR INSULATION CLASS IS NOT
PER LA LORO CLASSE DI ISOLAMENTO. EXCEEDED

3URWH]LRQH(1¬ Protection EN 60529

,3  FRQ FRQQHWWRUH ',1  PRQWDWR FRUUHWWDPHQWH Protection class is designated by the letter IP followed by two
digits: the first indicates protection against penetration of foreign
Il grado di protezione viene indicato con le lettere IP seguite da solid bodies, the second against penetration of water.
due cifre: la prima indica il grado di protezione contro la penetrazione
di corpi solidi estranei, la seconda contro la penetrazione di liquidi. IP 65 MEANS TOTAL PROTECTION AGAINST:
• DUST
IP 65 SIGNIFICA PROTEZIONE CONTRO: • LOW PRESSURE WATER JETS
• POLVERE
• ACQUA SPRUZZATA IN GETTI A BASSA PRESSIONE Our coils resist therefore to water sprayed from every direction
but CANNOT BE PLUNGED INTO WATER OR REMAIN UNDER
Quindi le bobine possono entrare in contatto on un getto d’acqua WATER.
ma NON POSSONO RIMANERE IMMERSE IN ACQUA. Protection class doesn’t apply to explosion risks or to conditions
Il grado di protezione non prende comunque in considerazione such as moisture, corrosive agents, mildew etc.
rischi di esplosione o condizioni particolari come umidità, ambienti
corrosivi, muffe, ecc.

7HQVLRQHGLDOLPHQWD]LRQH Inlet voltage

Per ottenere un corretto funzionamento ed una lunga durata di To obtain correct operation and long life of coils it is necessary
esercizio delle bobine è necessario che le variazioni della tensione that operating voltage fluctuations do not exceed ( 10 % of nominal
di alimentazione non siano superiori al (10% della tensione voltage.
nominale.

,VRODPHQWRWHUPLFR',19'( Heat insulation DIN VDE 0580

BOBINE STANDARD STANDARD COIL


BOBINA COMPLETA Classe F 155$C COMPLETE COIL Class F 155$C
Filo di rame smaltato 180$C Copper wire 180$C

BOBINE S-CE-H COILS S-CE-H


BOBINA COMPLETA Classe H 180$C COMPLETE COILS Class H 180$C
Filo di rame smaltato 200$C Copper wire 200$C

I valori indicati sono i massimi ammissibili per la temperatura These are the maximum allowable absolute temperatures
assoluta T = TA + 6T con TA = temperatura ambiente e T = TA + 6T where TA = ambient temperature and 6T = temperature
6T = variazione di temperatura dovuta al funzionamento. rise due to operation.
Quindi se ad esempio TA = 40$C ottengo 6T max = 115$C per For example, if TA = 40$C we obtain 6T max = 115$C if we have
rispettare il limite di 155$C e 6T max = 140$C per rispettare il to comply with the limit of 155$C and 6T max = 140$C if we have
limite di 180$C. to comply with the limit of 180$C.

La variazione di temperatura 6T viene calcolata dalla resistenza The temperature rise 6T is calculated from resistance at ambient
a temperatura ambiente e dalla resistenza a temperatura temperature and resistance at stabilized temperature, measured
stabilizzata, misurata secondo DIN VDE 0580: according to DIN VDE 0580:
• la bobina è montata su una valvola a cartuccia standard, a • coil is mounted on a standard cartridge valve inserted in a
sua volta montata su di un collettore standard in acciaio standard steel manifold on a wooden surface.
appoggiato su una superficie di legno.

9.50.04
Componenti s.r.l.

%2%,1(3(56(59,=,2&217,182²('
Continuous duty coils – ED 100% DATI TECNICI
Technical information

• la bobina è tenuta eccitata per 1 ora a tensione nominale con • coil is kept energized for 1 hour at nominal voltage, with ambient
temperatura ambiente TA = 20-25$C e ventilazione naturale. temperature TA = 20-25'C and natural ventilation.

Se ne deduce che LE BOBINE CLASSE F NON POSSONO CLASS F COILS ARE NOT RATED FOR CONTINUOUS DUTY
FUNZIONARE IN SERVIZIO CONTINUO SE LA TEMPERATURA ED = 100 % IF AMBIENT TEMPERATURE EXCEEDS THE
AMBIENTE SUPERA IL VALORE Tx = 155 - 6T $C VALUE Tx = 155 - 6T $C
IN QUESTI CASI DEBBONO ESSERE IMPIEGATE BOBINE IN IN THESE CASES CLASS H COILS SHOULD BE USED. AND
CLASSE H, E IN OGNI CASO SI RACCOMANDA DI NON IN ANY CASE FREE HEAT EXCHANGE AND NATURAL
IMPEDIRE IL LIBERO SMALTIMENTO DEL CALORE EVITANDO VENTILATION ARE NECESSARY FOR THE CORRECT
DI INCAPSULARE LE BOBINE IN INVOLUCRI CHIUSI ED OPERATION OF COILS.
A S S I C U R A N D O U N A A D E G U ATA A E R A Z I O N E .
EXTERNAL TEMPERATURE of coils is not directly related with
La TEMPERATURA ESTERNA delle bobine non ha nessuna 6T. After few minutes of continuous energizing, temperatures up
relazione diretta con il 6T. Tale temperatura, dopo alcuni minuti to 80 - 100$C can be reached, so care should be taken to avoid
di eccitazione continua, può raggiungere 80 - 100$C per cui accidental contact of people with hot surfaces.
dovranno essere prese opportune precauzioni per evitare il contatto
accidentale con tali superfici.

'HVFUL]LRQHFROOHJDPHQWRVROHQRLGHFRQFRQQHWWRUHVWDQGDUG
Description of coil connection with standard connector

&RQQHWWRUH
Connector




%RELQD
Coil

9.50.05
Componenti s.r.l.

127(',87,/,==2
Working conditions DATI TECNICI
Technical information

)OXLGRLGUDXOLFR Hydraulic fluid

&$5$77(5,67,&+(*(1(5$/, GENERAL PROPERTIES


Il fluido idraulico deve avere caratteristiche fisiche, lubrificanti e Hydraulic fluid must have physical, lubricating and chemical
chimiche tali da renderlo idoneo all’impiego in impianti oleodinamici, properties suitable for use in hydraulic systems such as for example
come ad esempio gli MINERAL HYDRAULIC OILS HL DIN 51524 Part1
OLI IDRAULICI A BASE MINERALE HL DIN 51524 Parte 1 MINERAL HYDRAULIC OILS HLP DIN 51524 Part2
OLI IDRAULICI A BASE MINERALE HLP DIN 51524 Parte 2
VISCOSITY DEGREE ISO 3448 – DIN 51519
*5$'2',9,6&26,7­,62²',1 ISO viscosity degree is expressed by ISO VG followed by one
Il grado di viscosità ISO viene indicato con le lettere ISO VG number representing the medium cinematic viscosity at 40$C in
seguite da un numero che rappresenta la viscosità cinematica mm2/s or centiStock cSt.
MEDIA a 40$C in mm2/s o centiStokes cSt.

Viscosità cinematica - Cinematic viscosity


Grado di viscosità
Viscosity degree Massima - Max Media - Medium Minima - Minimum
0$C 40$C 100$C
,629* 90  2,4
,629* 300  4,1
,629* 420  5,0
,629* 780  6,1
,629* 1400  7,8
,629* 2650  9,9

&ROODXGRIXQ]LRQDOH7HPSHUDWXUH7UDILODPHQWL Testing – Temperatures – Internal leakage

&2//$8'2)81=,21$/( FUNCTIONAL TESTING


Tutte le curve di funzionamento riportate a catalogo sono state rilevate All performance curves in this catalogue are obtained using mineral
utilizzando olio minerale con grado di viscosità ISO VG 46 alla temperatura based hydraulic oil with 46 cSt viscosity at 40$C ( ISO VG 46
di 40$C. Tutte le valvole vengono collaudate a queste condizioni su banchi viscosity class ).
prova che assicurano un GRADO DI FILTRAZIONE ASSOLUTA di 10
All valves go through functional testing at these conditions before
micron. Tutte le curve di funzionamento rappresentano la media dei valori
rilevati sulle valvole collaudate, pertanto i valori reali possono discostarsi
shipment.
da tali curve di ( 1-2 bar per le perdite di carico e di ( 20-30 ms per i tempi Our test stands ensure 10 micron ABSOLUTE FILTRATION.
di risposta. All performance curves represent the average of real values
measured on tested valves. For this reason a tolerance of ( 1-2
9$/25,/,0,7(',7(03(5$785$ bar for pressure drop and ( 20-30 ms for response time has to
TEMPERATURA AMBIENTE da -20$C a +50$C be considered normal and acceptable.
TEMPERATURA OLIO da -20$C a +80$C
Queste limitazioni di temperatura sono rese necessarie dai limiti di impiego TEMPERATURE RANGE
delle bobine elettriche standard in classe F e delle guarnizioni standard AMBIENT TEMPERATURE -20$C to +50$C
in NBR. Si raccomanda di rispettare tali limiti e di contattare il nostro Ufficio
OIL TEMPERATURE -20$C to +80$C
Tecnico per impieghi con campi di temperatura diversi.
It is strongly recommended not to exceed these temperature limits
75$),/$0(172,17(512²9$/92/($7(187$ whenever standard CLASS F coils and standard NBR seals are
Il VALORE MASSIMO AMMISSIBILE DI TRAFILAMENTO INTERNO per used. Please consult us for different temperature ranges.
le valvole a tenuta è di 1 cm3/min (15-20 gocce/min) alla massima pressione
di esercizio e con olio a viscosità 46 cSt. In realtà il trafilamento è INTERNAL LEAKAGE – POPPET VALVES
mediamente inferiore a 10 gocce/min e tende in ogni caso a ridursi dopo MAXIMUM ALLOWABLE INTERNAL LEAKAGE of all poppet
alcuni secondi. valves cannot exceed 1 cm3/min (15-20 drops/min) at the maximum
working pressure with 46 cSt oil viscosity. Actual leakage is
expected, on average, to be less than 10 drops/min and anyway
tends to decrease after few seconds.