Clock Spring Application

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

CLOCK SPRING

REPAIR APPLICATION INDEX SHEET

Corrosion

Mechanical
Damage and Third
Party Interference

Bends

Girth Welds

CLOCK SPRING

Tight Access

Riser

High Temperature

Sub-Sea

CLOCK SPRING

Low Pressure

Pipe Supports

Interfaces

Leak Repairs

CLOCK SPRING

Refinery

Mill Defects

Crack Arrest

FOR FURTHER INFORMATION ON CLOCK SPRING REPAIR SOLUTIONS CONTACT:

Email: [email protected]; [email protected]


Email: [email protected]

CLOCK
SPRING COMPANY, L.P.

New Delhi
India

Tel: + (91) 11 23314928


Fax: + (91) 11 23315679
Email: [email protected]

Clock Spring Various Pipeline Repairs Criteria


1- Clock Spring
Length
Number of layers
Defect Size
Pressure
Size Availability
Temperature range

:
:
:
:
:
:

Delivery

Standard 11.500" 0.500" (292 mm 13 mm).


8 continuous layers regardless of pipeline size.
Up to 80% external metal loss.
Unlimited
4 56
-64C < Temperature <60 C (Standard Temperature)
60C < Temperature < 90 C (High Temperature)
1 working week

2- Snap Wrap
Length
Number of layers

:
:

Defect Size
Pressure
Size Availability
Temperature range
Delivery

:
:
:
:
:

Standard 11.50" 0.50" (292 mm 13 mm).


8 Individual Split Sleeves for < Dia<8
4 Individual Split Sleeves for 8 Dia.
Up to 90% external metal loss.
Up to 500 PSI
upwards
-64C < Temperature < 90 C
1 working week

3- Pipe Support
Length
Number of layers
Defect Size
Pressure

:
:
:
:

Size Availability
Temperature range
Delivery

:
:
:

Standard 11.50" 0.50" (292 mm 13 mm).


2 Individual Split Sleeves regardless of size
Up to 30% external metal loss.
Designed as full encirclement wrap to provide
wear surface and eliminate crevice corrosion at
pipe support interface.
upwards
-64C < Temperature < 90 C
1 working week

4- Leak Stop
Length of Repair
Number of layers
Defect Size
Pressure

:
:
:
:

Size Availability
Temperature range
Delivery

:
:
:

Any length of repair


Application dependent
Holes up to 1 Diameter
Tested as part of the AEA program and accepted for use up
to 80 bar as a 20 year repair.
2 part metal Polymer Paste
-64C < Temperature < 90 C
1 working week

New Delhi Representative Office: Allied Engineers, 213 New Delhi House, 27 Barakhamba road
Tel: + (91) 9711932606, 9811734349

CLOCK SPRING
Products and Services
CLOCK SPRING
50 year DOT approved repair system for high pressure transmission pipelines
Unidirectional fiberglass polyester or vinyl ester composite repair sleeve
Restores full strength to pipelines with up to 80% external wall loss
Available in 4 through 56 diameter kits with coil, filler, adhesive, tools
Can be applied on bends and girth welds
Pipelines do not have to be shut down or decreased in pressure
No hot work, welding or cutting
Fast and economical
Temperatures up to 220 F (104C)

SNAP WRAP
Pipe repair system for lines operating at 500 PSI (34.5 bar) or below
through 56 diameter kits with coils, filler, adhesive and installation tools
Split sleeve design allows for applications with a clearance of less than a
Restores pipe to full pressure handling capability
Fast and economical
No hot work, welding or cutting

PIPE SUPPORT
Heavy duty double sleeve composite wrap
Full encirclement design eliminates crevice corrosion, provides wear surface
through 56 diameter kits with coils, filler, adhesive and installation tools
Heavy duty double coil composite wrap
Easy installation with minimum clearance required
Cures in two hours

CONTOUR
Custom engineered advanced composite repair products
Non-Woven glass fiber and durable toughened epoxy
Repair elbows, tees, reducers, and other complex geometries
Repair of carbon steel, stainless steel, and other pipe materials
Highly durable and excellent chemical resistance to common process fluids
Temperature to 275F (135C)
Engineering Design service to ISO TS 24817, ASME PCC R&T, Article 4.1

INSTALLATION AND TRAINING


DOT certified Clock Spring installation training in the field or in the shop
Monthly DOT certified trainer class at the Clock Spring factory in Houston, Texas

high pressure gas transmission, water lines, hydrocarbons, chemicals,


corrosion, leaks, dents, bends, tees, reducers, risers, jetties
FOR FURTHER INFORMATION ON CLOCK SPRING REPAIR SOLUTIONS CONTACT:

Email: [email protected]; [email protected]


Email: [email protected]

You might also like