2024 - Product Catalog Ultracentrifuge
2024 - Product Catalog Ultracentrifuge
2024 - Product Catalog Ultracentrifuge
ULTRACENTRIFUGES
PRECISION-MADE PERFORMANCE
P R O D U C T C ATA L O G
ULTRA POWERFUL SO QUIET
SOPHISTICATED MULTILINGUAL
INTELLIGENT ALWAYS SECURE
SYSTEMATIC EXELLENCE
INTRODUCTION
Since the introduction of the first commercial ultracentrifuge in 1947 Rotors with the BioCertified symbol have been tested to demonstrate
— the classic Beckman Model L — Beckman Coulter Life Sciences has containment of aerosols under normal operating conditions of the
been at the forefront of centrifuge innovation. Although the physics associated Beckman Coulter centrifuge when used and maintained
of this basic separation technique never change, we continually as instructed.
design new and innovative rotors and accessories, and develop
advanced methods that allow the forces of centrifugation to be
applied in new ways.
Disclaimer: The content included in this catalog is for reference purposes only. The most accurate and up-to-date information
is located in Instrument and Rotor Instructions For Use which are available at beckman.com/techdocs
Experience the visibility and control of our intelligent user interface that makes the Optima X Series
a breeze to operate. Our entry-level model, the XE delivers all of the features required to quickly set
up and complete a run. Our premium model, the XPN, boasts networking capability and a variety of
customizable security and tracking features, ensuring chain of custody and compliance. Both models
feature multi-layered BioSafety features in order to maintain a safe working environment. And, as
you have come to expect, all instruments are designed as a total system with our innovative rotors
and labware.
3. Tabletop UC
Remote monitoring and control (XPN only) Powerful on-board simulation and calculation
Saves time. Start, stop, and monitor from computer or smart phone.
tools (XPN only)
Receive diagnostic alerts via e-mail. iPhone or Android compatible. Saves time and samples. Proprietary software optimizes protocols
before running to ensure maximum efficiency. Quickly perform
common calculations and conversions.
chain of custody and compliance. Export run and system logs for
record keeping. Manage rotor life by serial number.
Quiet-drive technology
Designed for low drive noise. Operates at less than 51 dBA.
Part Numbers*
6. Accessories
2. Floor Prep UC
Giant LCD touchscreen display. Approximately 15 inch (38 cm) • •
Intuitive, multilingual interface • •
Improved power tolerance • •
Compatible with existing Beckman Coulter rotors • •
Step-by-step zonal/CF operation screens • •
Rotor tracking by serial number •
User-defined programs •
Remote monitoring and control •
3. Tabletop UC
Password protection and three user access levels •
Exportable run logs and electronic signatures •
eXPert simulation software •
Speed/temperature vs. time plot •
Specifications
4. Micro-UC
Maximum speed (rpm) 100,000 100,000
90,000 90,000
80,000
5. Tubes
Accel/decel profiles 10 accel/11 decel
Operating languages English, French, Italian, German, Spanish, Japanese, Russian, Korean, and Chinese (Simplified)
6. Accessories
Electronic signature Yes No
Data transfer (3) USB 2.0 type A connectors, (1) RJ-45 connector No
125.7 x 94 x 68.1 cm
Dimensions (H x W x D)
49.5 x 37 x26.8 in
Fixed-Angle Rotors
92 500 62
Near-Vertical Rotors
Vertical Rotors
Swinging-Bucket Rotors
SW 32 Ti 6 x 38.5 mL
No. 369694. SW 32 Ti Rotor Package. Includes Rotor, 1 box 326823 Polypropylene Tubes, 2 boxes 344058 Ultra-Clear Tubes, 1 box 355631 Polycarbonate Tubes, 1 each
3. Tabletop UC
331186 Bucket Holder Rack, 306812 Spinkote Lubricant, 335148 Vacuum Grease, 335456 Overspeed Disk, 978354 hooked O-ring Removal Tool, and 24 each
812715 O-rings.
No. 369650. SW 32 Ti Rotor Assembly.
Polypropylene
Note: To help you locate g-Max tubes in the rotor listings, these tubes are
Rotor Replacement Parts
highlighted with bold, italic type.
§§ Set of 2. 331186 Bucket Holder Rack
C46871 Rotor Stand
* Sterile and C-Free options available. 335456 Overspeed Disk, 32 000 rpm
7. Reference
The buckets of the SW 32.1 can be used with the SW 32 rotor head.
369693 Bucket Assembly, with Caps and O-rings, set of 6
Adapters/Spacers
2. Floor Prep UC
of tubes is ordered: the particular technique to be used, the nature of the sample and any solvent or gradient media, the desirability
of reusing the tubes, and certain convenience factors. The properties listed below provide a guide for anyone involved in the tube
selection process.
• Strength and Flexibility, to resist permanent deformation even when run in fixed-angle rotors without tube caps.
3. Benchtop UC
• Thin enough to be sliced or punctured after centrifugation for fraction collection.
• Impermeable to Water, to prevent aqueous solutions from permeating the tube wall and reaching the rotor cavity.
• Surface Properties that prevent the adherence of nucleic acids and proteins.
• Temperature Tolerance throughout a wide range of operating temperatures, without deforming at high temperatures or cracking
when used close to 0°C.
The full line of Beckman Coulter tubes includes a number of tube materials, each with its own distinct combination of properties, to meet a
4. Micro-UC
variety of application requirements. Available are transparent, translucent, and opaque tubes, tubes that can be sliced or punctured, tubes
that can be sterilized and reused, and tubes that are resistant to a variety of chemical compounds.
5. Tubes
6. Accessories
7. Reference
8. Support
2. Floor Prep UC
finding potential new cures, protecting your sample from degradation and contamination during your
study is paramount.
Ideal for Genomics, Exosomes, and Proteomics workflows Ideal for Protein Prep and Virus Purification workflows
3. Benchtop UC
• Prevents sample degradation and contamination • Includes all advantages of being certified free
*Based on sample results below detectable limits. • Sterilized and packaged compliant with
ISO 11135 and 11607
4. Micro-UC
• Certificates available on beckman.com
Selection Guide
Nominal
Nominal size Beckman Certified Certified
Tube type Capacity Compatible rotors
(mm) Standard Free Free + Sterile
(mL)
5. Tubes
Ultra-clear Open-top
13.2 14x89 344059 C14277 C14293 SW 41 Ti
Round Bottom
Type 90 Ti, Type 70.1 Ti, Type 70 Ti, Type 50.4 Ti,
6.5 13x64 344088 C14280 C14296
Type 50.2 Ti, Type 45 Ti, MLA-55
6. Accessories
38.5 25x89 326823 C14285 C14301 Type 70 Ti, 50.2 Ti, SW 32 Ti, SW 28, JS-24.38
Polypropylene
30 25x89 358126 C14291 C14307 SW 32 Ti, SW 28, JS-24.38
Open-top konical
7. Reference
8. Support
4.9 13 x 51 362185 VTi 90, VTi 65.2, NVT 90, NVT 65.2
8.9 16 x 60 361623 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 50, MLA-55
32.4 25 x 77 361625 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, 42.1, 30, SW 32 Ti, SW 28, MLA-50
2.0 13 x 25 345829 Types 100 Ti, 50.4 Ti, 50.3, NVT 100, NVT 90, NVT 65.2, VTi 90, VTi 65.2, SW 55 Ti,
SW 50, TLA-110, TLA-100.4, TLA-100.3, MLS-50
4.2 16 x 32 356562 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 40, SW 30.1, SW 32.1 Ti, SW 28.1, MLA-80, MLN-80, MLA-55
5.1 13 x 51 342412 VTi 90, VTi 65.2, NVT 100, NVT 90, NVT 65.2
6.3 16 x 45 345830 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 50, 40, NVT 65, VTi 65.1, SW 30.1, SW 32.1 Ti,
SW 28.1, MLA-80, MLN-80, MLA-55
5. Tubes
8.0 16 x 58 344621 Type 50, NVT 65, VTi 65.1, SW 32.1 Ti, SW-28.1, MLA-80, MLN-80
10.0 16 x 67 344622 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti ,40, NVT 65, VTi 65.1, SW 32.1 Ti, SW 28.1, MLA-55
13.5 16 x 76 342413* Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti ,40, NVT 65, VTi 65.1, MLA-55
15.0 25 x 38 343664 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, VTi 50, VTi 50.1, SW 30, SW 32 Ti, SW 28, MLA-50
27.0 25 x 64 343665 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, 42.1, VTi 50, VTi 50.1, SW 32 Ti, SW 28, MLA-50
33.0 25 x 83 344623 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, SW 32 Ti, SW 28
6. Accessories
39.0 25 x 89 342414* Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, VTi 50, VTi 50.1
1.3 11 x 35 358655 SW 60 Ti
3.0 11 x 60 358648 SW 60 Ti
5.1 13 x 51 344075 NVT 90, NVT 65.2, VTi 90, VTi 65.2
13.5 16 x 76 344322 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 40, NVT 65, VTi 65.1, MLA-55
8. Support
2. Floor Prep UC
Quick-Seal Ultra-Clear Tubes (cont’d)
15.0 25 x 38 344324 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, VTi 50, VTi 50.1, MLA-50
27.0 25 x 64 344323 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, VTi 50, VTi 50.1, MLA-50
39.0 25 x 89 344326* Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, VTi 50, VTi 50.1
Ultra-Clear Tubes
3. Benchtop UC
450 μL 8 x 20 345843 A-95
2.0 8 x 49 344091 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 50.4 Ti, 50.3 Ti, 50, 40, MLA-55
3.0 13 x 32 344092 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 50, 40, MLA-55
4.0 11 x 60 344062* SW 60 Ti
4.0 13 x 41 344093 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 50, 40, MLA-55
6.5 13 x 64 344088* Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.4 Ti, 50.3 Ti, 50.2 Ti, 50 Ti,
4. Micro-UC
45 Ti, 40.3, 40.2, 40, 21, MLA-55
13.2 14 x 89 344059* SW 41 Ti
13.5 16 x 76 344085 Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.2 Ti, 50 Ti, 45 Ti, 40, 21, MLA-55
14.0 14 x 95 344060* SW 40 Ti
38.5 25 x 89 344058* Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, SW 32 Ti, SW 28
5. Tubes
Thinwall Polypropylene Tubes
4.0 11 x 60 328874* SW 60 Ti
6.5 13 x 64 326820 Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.4 Ti, 50.3 Ti, 50.2 Ti, 50 Ti,
45 Ti, 40, 40.3, 40.2, 21, MLA-55, MLA-50
6. Accessories
13.2 14 x 89 331372* SW 41 Ti
13.5 16 x 76 326814 Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.2 Ti, 50 Ti, 45 Ti, 40, 30, 21, MLA-55, MLA-50
14.0 14 x 95 331374* SW 40 Ti
38.5 25 x 89 326823* Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, SW 32 Ti, SW 28
1.5 11 x 35 358117 SW 60 Ti
3.0 11 x 60 355636 SW 60 Ti
4.0 13 x 64 355644 "Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.4 Ti, 50.3
Ti, 50.2 Ti, 50 Ti, 45 Ti, 40, 21, MLA-55, MLA-50
10.0 16 x 76 355640 "Types 90 Ti, 80 Ti, 75 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.2
Ti, 50 Ti,45 Ti, 42.1, 40, 35, 30, 21, SW 25.1, MLA-55, MLA-50
32.0 25 x 89 355642 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, SW 32 Ti, SW 28
4. Micro-UC
3.0 11 x 60 355635 SW 60 Ti
5. Tubes
4.0 13 x 64 355645 "Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.4 Ti,
50.3 Ti, 50.2 Ti, 50 Ti, 45 Ti, 40, 21, MLA-55, MLA-50
10.0 16 x 76 355630 "Types 90 Ti, 80 Ti, 75 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.2
6. Accessories
32.0 25 x 89 355631 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, SW 32 Ti, SW 28
38.5 25 x 89 301112 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, 42.1,
Polyethylene Tubes
(Natural)
O-ring or
Cap Material Tube Cap Hex Nut Crown Set Screw Insert Stem
Gasket
Set Screw
Insert
SUPPORT SERVICES
Field Service Support Sometimes rotor corrosion is so bad it can be seen with the
naked eye, while at other times it is not so apparent. If you have
Most of us appreciate the need for careful design, handling, and
doubt about the condition of a single Beckman Coulter rotor, you
2. Floor Prep UC
Our Field Rotor Inspection Program (FRIP) has two purposes: to • The proper way to clean and store rotors.
prevent premature rotor failures by detection of stress corrosion, • How to get longer life from your rotor.
metal fatigue, wear or damage to anodized coatings; and to instruct
laboratory personnel in the proper care of rotors. On-Site Rotor Inspection and Maintenance
Specially trained Beckman Coulter Field Service engineers are
Contact your local Beckman Coulter Service Office for details on
5. Tubes
maintenance procedures, rotor damage, and its significance. Throughout the world, Beckman Coulter Field Service engineers are
The stress corrosion of aluminum rotors, in particular, can be greatly on hand to provide the support you need. So you can operate your
reduced by good laboratory practice. centrifuges worry-free, a number of programs are in place that cover
preventive maintenance of your system, including parts, labor, drive
For more information about the Field Rotor Inspection Program systems, and rotors. It all adds up to a comprehensive approach to
(FRIP), please contact your Beckman Coulter Life Sciences maximizing your system investment.
representative.
Contact your local Beckman Coulter Sales and Service office to find
out the specifics about the program available in your area.
7. Reference
8. Support