AC CURRENT & VOLTAGE TRANSDUCER MODEL

PA

■ FEATURES
Accuracy 0.1%F.S.(TRMS),0.25%F.S.(RMS)

Wide selection of input/output range


Dielectric strength 2KVac/1min. (input/output/power)


Impuse test 5KV(1.2x50us)(IEC255-4,ANSI C37.90a/1974)


Surge test (ring wave)2.5KV(0.25ms/1MHz)(IEC255-4)


Dimension small and High stability


1:MODEL:PA □ - □ □ □-□ □

NO Input Unit NO Input Type NO Input Range NO Frequency NO Output Range NO Output Range NO Aux. Power
1 1 unit A Voltage(RMS) 1 AC0-120V A 50Hz A DC0-50mV F DC0-1mA A AC110V/220V
3 3 units B Current(RMS) 2 AC0-240V B 60Hz B DC0-1V G DC0-10mA B AC/DC20~60V
O SPECIFIED 3 AC0-400V C 400Hz C DC1-5V H DC0-20mA C AC/DC90~260V
4 AC0-1A D SPECIFIED D DC0-10V I DC4-20mA Less 3VA for ●

5 AC0-5A AC/DC input


Frequency ±10% E

DC2-10V O SPECIFIED
9 SPECIFIED

2:SPECIFICATION 3.Terminal connection


● Measuring accuracy : 0.25%F.S.(RMS) (23 ±5℃) INPUT
1 2 3 4 5
● Input burden : <0.2VA(voltage)
(PA1)
<0.2VA(current)
OUTPUT Aux.Power
● Maximum input over : Current related input:3 x rated continuous
6 7 8 9 10
10 x rated 30 sec. ,25 x rated 3sec. 220V110V 0V
50 x rated 1sec.
Voltage related input:maximum 2x rated continuous
● Response time : <250ms (0-90%)
INPUT
A B C
● Output drive capability : <10mA for voltage mode
1 2 3 4 5 6 7 8 9 10
<10V for current mode
● Output ripple(p-p) : <0.1% F.S.
(PA3)
OUTPUT
● Zero (offset) range : 0-±5% F.S. A B C Aux.Power
11 12 13 14 15 16 17 18 19 20
● Span (scale) range : 0-±10% F.S. 220V110V 0V

● Temp. coefficient : 100ppm/℃ (0-50℃)


4.Dimension(unit:mm)
● Isolation : Input/Output/Power/Case
●PA1
● Insulation Resistance : >100Mohm with 500V DC

● Dielectric strength : 2KVac/1 min. (input/output/power)


77.2
● Impulse test : ANSI C37.90a/1974,DIN-IEC 255-4
impulse voltage 5KV (1.2 x 50us)
● Surge test(ring wave) : 2.5KV-0.25ms/1MHz 1 2 3 4 5

● Operating condition : 0-50℃(20 to 90% RH non-condensed)


72.5 116
● Storage condition : 0-70℃(20 to 90% RH non-condensed)
● CE EMC Certification : EN 55022:1998/A1:2000 Class A
EN 61000-3-2:2000
EN 61000-3-3:1995/A1:2001
6 7 8 9 10
EN 55024:1998/A1:2001

45

● PA3 see PW Transducer dimension