Clarifier Tank Calc

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

DESIGN CALIFIER TANK

(SLUDGE BLANKET CLARIFIER TYPE : VERTICAL SLUDGE BLANKET)


1. Flow Rate
Q

3
150 m /hr

2. Raw Water Quality input


1 Turbidity
2 pH
3 Alkalinity

=
=
=

4 Temperature
=
5 Fe
6 Mn
7 Total Hardness

15:26/25/10/2006

NTU
mg/l as CaCO3
o

C
mg/l
mg/l
mg/l as CaCO3

1/1

Design Clarifier Tank/Design Flow

3. Design Criteria
3.1. Kawamura
3.1.1 Flocculation Time
3.1.2 Settling Time
3.1.3 Surface Loading
3.1.4 Weir Loading
3.1.5 Upflow Velocity
3.1.6 Slurry Circulation rate

= approximate =
= 1 - 2 hr
= 2 - 3 m/hr

20

min

3
= 7.3 - 15 m /hr
= < 10 mm/min
= up to 3 - 5 time the raw water inflow rate

-1
3.1.7 G
= 30 - 50 s
3.1.8 MAXIMUM MIXER TIP SPEE 0.9 m/s
(Baffled Channel)
= 0.9 m/s
(Horizontal Shaft with Paddles)
= 1.8 - 2.7 m/s (Vertical Shaft with Paddles)
Equation mixer tip speed = DN

3.2. Q,Sim
3.2.1 Detention Time
3.2.2 Surface Loading

= 2 Hr
= 2 - 4 m/hr

3.2.3 Weir Loading

3
= 7.1 m /m.hr

3.3. Sheet Master Degree of Environmental Engineering


3.3.1 Weir Loading
3.3.2 Surface Koading

3.3.3
3.3.4
3.3.5
3.3.6
15:27/25/10/2006

3
= 7.1 m /m.hr

- Q < 0.35 m3/min

= 0.5 - 1.0 m/hr

- Q > 0.35 m3/min


Water Depth
Paddle radius
Detention Time
Diameter Tank

=
=
=
=
<

1.25 - 1.85 m/hr


3 - 5 m.
65 - 75% of radius for Flocculator
1 - 3 Hr
45 m
1/2

Design Clarifier Tank/Design Criteria

3.3.7 Paddle at bottom tank high bottom


= 15 - 30 cm
3.3.8 Paddle Velocity
= 2 - 3 rpm
3.3.9 Effective Paddle Area = 10 % Sweep area of the fllocculator
3.4. Water Work Engineering Book
3.4.1 Flocculation
2.4.1.1 Detention Time = 20 - 60 min
-1
2.4.1.2 Velocity Gradie = 15 - 60 S

2.4.1.3 GT = 1x104 - 15x104


2.4.1.4 Periperal Velocity of Paddle
= 0.3 - 0.6 m/s
2.4.1.5 Shaft rotation speed = 1.5 - 5 rpm
3.4.2 Sedimetation (Coagulation)
2.4.2.1 Detention Time = 2 - 8 hr
3 2
2.4.2.2 Surface Loadin = 20 - 40 m /m .day
3
2.4.2.3 Weir Loading = 200 - 300 m /m.day
3.4.3 Sedimentation (Softening)
2.4.3.1 Detention Time = 1 - 6 Hr
3 2
2.4.3.2 Surface Loadin = 40 - 60 m /m .day

2.4.3.3 Weir Loading

15:27/25/10/2006

3
= 250 - 350 m /m.day

2/2

Design Clarifier Tank/Design Criteria

4 GiveContact Time in Hopper inside (Flocculation Zone)

30 min

5 Flow Rate
6 Volume in Hopper inside

3
=
150 m /hr
=Q xt

=
75
7 Give Detention Time in Hopper outside (Sedimentation Zone =
2
8 Volume in Hopper outside
=Q xt

m3
Hr

300

m3

9 Calculation Diameter Hopper inside


Give D1

Surface Area

A1

10 Theory Volume of Conical Basin

m2

= 7.06858
=

d
A1 + A2 +
3

Give Water Depth

A1 x A2

=
75 m
45 = 7.06858 + A2 + 2.658681

A2

0 = -37.9314 + A2 + 2.658681

A2

( A2 ) 2

= 4.97134

A2

= 24.7142

Theory Surface Area

m2

Volume Hopper inside


Then

D 2

m2

D 2

D2

D2

Then

D1
D2

Water Depth
15:27/25/10/2006

=
=

31.4671
5.60956

=
=
=

3
6
5

m.
m.
m.

1/2

m.

Design Clarifier Tank/Hopper inside&outside

11 Actual Volume in Hopper inside


Theory Volume of Conical Basin
A1

A2

D 2

D 2

d
A1 + A2 +
3

A1 x A2

7.068583

m2

28.27433

m2

Calculate Acture Volume in Hopper inside


Volume in Hopper inside

12 Acture Contact Time

V
Q

d
A1 + A2 +
3

A1 x A2

82.46681

m3

82.46681
150

0.549779 Hr.

32.98672 min.

13 Calculate Diameter in Hopper Outside (Sedimentation Zone)


Volume in Hopper Outside (Sedimentation Zone)
=

A2

D 2
4

Theory Volume of Conical Basin

229.4801

28.27433 + A3 + 5.317362

A3

-201.206 + A3 + 5.317362

A3

11.77303

m2

138.6043

m2

( A3 )

A3

15:28/25/10/2006

m3

m2

28.27433

Calculate A3

300

1/4

d
A2 + A3 + A2 x A3
3

Design Clarifier Tank/Acture Volume&Contact time

138.6043

m3

D3

13.28177

28.27433

m2

138.5485

m2

14 Calculate Acture Volume in Hopper outside + Outside

D3 2
4

Acture Volume in Hopper outside


A2

D2 2

A3

D3 2

d
A2 + A3 + A2 x A3
3

382.3529

m3

- Volume in Hopper inside

82.46681

m3

- Volume in Hopper outside

299.8861

m3

Volume in Hopper outside + Outside

Conclusion

15:28/25/10/2006

2/4

Design Clarifier Tank/Acture Volume&Contact time

15 Detention Time in Hopper outside

V
Q

1.999 Hr.

1.5 m.

16 Calculate Paddle
16.1 At Depth level

Slope
Then

=
3.333333 =

X1

3.333 m.
1.5 X1

0.45 m.
3.9 m.

Diameter Paddle

Sweep Area

D 2

m2

= 11.94591

Paddle Area = 10 % of Sweep area(Bhole,A.G, Personal Communication)


= 1.195

m2

Assume There are paddle.


4
paddles
Length of each paddle = 65 - 75 % of Radius of Flocculation selection 70 %
- At depth level

15:29/25/10/2006

1.5

m.

Diameter of Flocculator =

Radius
= 1.95 m.
Length of each paddle
=
Height of each paddle =

Area
Length x 4

1/3

1.365
=

3.9

m.

0.218789

m.

m.

Design Clarifier Tank/Detention Time&Paddle Area

16.2 At Depth level

Slope
Then

=
3.333333 =

X2

3.5 m.
3.333 m.
3.5 X2

1.05 m.
5.1 m.

Diameter Paddle

Sweep Area

D 2

m2

= 20.42821

Paddle Area = 10 % of Sweep area(Bhole,A.G, Personal Communication)


m2

= 2.043

Assume There are paddle.


4
paddles
Length of each paddle = 65 - 75 % of Radius of Flocculation selection 70 %
- At depth level

3.5

m.

Diameter of Flocculator =

Radius
= 2.55 m.
Length of each paddle
=

Height of each paddle = Length x 4

Area

16.3 At Depth level

15:29/25/10/2006

1.785

Slope
Then

=
=
3.333333 =
X3

5.1

m.

0.286109

m.

m.

4.7 m.
3.333 m.
4.7 X3
1.41 m.

2/3

Design Clarifier Tank/Detention Time&Paddle Area

Diameter Paddle

Sweep Area

5.8 m.
D 2

m2

= 26.60332

Paddle Area = 10 % of Sweep area(Bhole,A.G, Personal Communication)


= 2.66

m2

Assume There are paddle.


4
paddles
Length of each paddle = 65 - 75 % of Radius of Flocculation selection 70 %
- At depth level

15:29/25/10/2006

4.7

m.

Diameter of Flocculator =

Radius
= 2.91 m.
Length of each paddle
=
Height of each paddle =

Area
Length x 4

3/3

2.037
=

5.82

m.

m.
0.326501

m.

Design Clarifier Tank/Detention Time&Paddle Area

17 Power Requirement
Give Shaft rotation speed

rpm (Design criteria = 2 - 3 rpm.)

17.1 At depth level


=
1.5 m.
Radius of Paddle = 1.365 m.
The rotation speed of paddle
= 2rN
= 0.428827 m/s
Design Criteria < 0.9 m/s (Horizontal Shaft with Paddles)
17.2 At depth level
=
3.5 m.
Radius of Paddle = 1.785 m.
The rotation speed of paddle
= 2rN
= 0.560774 m/s
Design Criteria < 0.9 m/s (Horizontal Shaft with Paddles)
17.3 At depth level
=
4.7 m.
Radius of Paddle = 2.037 m.
The rotation speed of paddle
= 2rN
= 0.639942 m/s
Design Criteria < 0.9 m/s (Horizontal Shaft with Paddles)
18 Calculation Relative of Paddle with respect to water
m/s
V = 0.75V paddl e
18.1 At depth level

1.5

m.

V paddl e

18.2 At depth level

3.5

m.

V paddl e

18.3 At depth level

4.7

m.

V paddl e

15:29/25/10/2006

1/1

=
=

0.428827
0.321621

m/s
m/s

=
=

0.560774
0.420581

m/s
m/s

=
=

0.639942
0.479957

m/s
m/s

Design Clarifier Tank/Calculation Velocity Paddle

19 Calculation Power requirement


Theory

1
C D A p ( v ) 3
2

Where :
P
CD

=
=

Power requirement of Mixing (watt) or N.m/s


Coefficient of drang of Paddle
=

Ap

Area of Paddle (m2)

=
=

3
mass fluid density (kg/m3)
= 1,000 kg/m
Relative velocity of Paddle with respect to water (m/s)

1.8

Then
P

Efficiency Motor at

=
60

437.27
% =

watt
728.78

or N.m/s
watt

or N.m/s

(From 1 HP = 0.7457 Kilowatt)


Then

15:30/25/10/2006

0.97730575

HP

1/1

HP

Design Clarifier Tank/Power Requirement

20 Calculation Velocity Gradient (G)


P
Theory
G =
V

Where :
G
P

= mean velocity gradient (sec-1)


= power requirement for mixing (watt) or N.m/s

= dynamic viscosity (N.s/m2)

= volume of the tank (m3)

G =

1,933 N .m / s
10 N .s / m 2 x82.49 m 3

G =

94.00646 sec

0.001 N.s/m

-1

21 Outlet Clarifier Tank


3
= 7.3 - 15 m /m.hr
= 13.28177137 m.
Minus outlet hole 2 side =
1
m.
Length of weir
= 12.28177137 m.

Weir Loading
From Diameter D3

Theory

Length of weir

Weir Loading

Q (m 3 / hr )
Weir Loading (m 3 / m.hr )
3
= 12.21322198 m /m.hr OK.

Give Diameter of Orifice =


1 in. =
Give 1 m. of outlet weir have orifice =
25

2 side =
50
Length of Orifice
=
1.27

1 side =
0.635
Then Free Space of weir
=
0.365
15:30/25/10/2006

0.0254
m.
pores/side
pores
m./ 1 m. weir
m./ 1 m. weir
m./ 1 m. weir
1/2

Velocity Gradient&outlet/Design Clarifier Tank

Space between orifice to orifice =


=

0.0146 m.
1.46 cm.

Give 1 m. of outlet weir have orifice =

2 side =
Then total orifice
=

25
50
614

pores/side
pores
pores

Then sum area of orifice

0.31

m2

22 Flow Rate pass through 1 orifice =

0.244

m3/hr

Each of orifice area

D 2
4

2
Each of orifice area = 0.0005067 m

Theory

Q =

Av

Velocity pass through each orifice =

15:30/25/10/2006

0.133906

2/2

m/s

Velocity Gradient&outlet/Design Clarifier Tank

23 Inlet Structure
From Static Mixer Design criteria velocity pass through static mixer = 1 - 2 m/s
Select velocity =
1.5 m/s
Theory

Q =

Area

Av

Q
v

m2

2
= 0.027778 m

Circular pipe area

D 2
4

D2
D

= 0.035368
= 0.188063
= 7.404063

m.
in.

in.

24 Calculation Surface Loading (Sedimentation Zone)


Surface Area at Sedimentation Zone

Doutside2

Dinside2
4

Dinside

=
=

13.28177
3

m.
m.

Surface Area at Sedimentation Zone

131.4799

m2

Surface Loading

Q
A

Doutside

=
Design Criteria 1.3 - 1.9 m/hr upflow (radial upflow type)
Text Book (Chularrongkron University < 4.2 m/hr.
Water Works Engineering 0.8333 - 1.6666 m/hr

15:30/25/10/2006

1/1

1.140859

m/hr.

Inlet structure&surface loading/Design Clarifier Tank