ChroZen GC Brochure ENG 2022
ChroZen GC Brochure ENG 2022
ChroZen GC Brochure ENG 2022
GC
This Value Is Not Negotiable
This Is Enough!
With accuracy and precision for each analysis, we will make a way.
YOUNG IN Chromass producing reliable and superior chromatographs for over 30 years has proudly launched
our 6th generation of GC, the new ChroZen GC, by our commitment to maximize customer satisfaction with
our instruments. ChroZen GC equipped with the state-of-the-art technology in both hardware and software
enhances the user convenience and the data reliability while delivering the exceptional analytical solutions.
680A GC
M600D GC
1991
1995
Acme 6000 GC
2001
YL6100 GC
2006
YL6500 GC
2012
2020
▪ P
ulsed pressure mode (Split/Splitless): Instantly increased forefront pressure at injection minimizes the sample
dispersion to provide significant sensitivity
YOUNG IN Chromass 3
Accuracy and Precision is what ChroZen GC values most.
ChroZen GC with powerful and stable UPCs (Ultimate Pneumatic Control) ensures data reliability and facilitates the
most remarkable repeatability in both RT (Retention Time) and area that considered as one of significant factors for
estimating how good the GC performs.
[pA]
40
30 C12
C14
C16
current
20
10
± 0.002 psi
± 0.001 mL/min
cooling down time to reach within 3.8 minutes from 450℃ 3.6
improve productivity.
3.2
3
Test 1 Test 2 Test 3 Test 4 Test 5
Much Faster, 50~70% decrease in the average analysis time with H2 as a carrier gas!
The Van Deemter equation describes the column efficiency varying with mobile phase velocity and hydrogen has much greater
velocity range while providing the desired separation and optimizing overall productivity. Thus, using a hydrogen as a carrier gas
can lead significant time saving and the faster linear velocity eluted components faster that ends up with more narrow peaks,
higher sensitivity in other words, while maintaining peak separations. However, all of these benefits should come with safety,
which can be ensured by ChroZen GC equipped with hydrogen leak detector (Option) to avoid much of the risk.
[pA]
0.40
0.02
0.00
0 10 20 30 40 [min]
Time
[pA]
0.40
0.02
0.00
0 10 20 30 40 [min]
Time
Much Longer, Consider target compounds only for column longevity by backflush
Backfulsh technique delivers the decrease in analysis time as [pA]
well as the enhanced column life time by reversing the column 200
0 10 20 30 40 50
Time [min]
YOUNG IN Chromass 5
ChroZen GC Is on the Ball, Superior Sensitivity
Pulsed Pressure Mode (Available with Capillary Inlet)
In the pulsed pressure mode, ChroZen GC instantly increases forefront pressure at injection to avoid the sample
dispersion and minimizes backflash exceeding the liner volume as well as carry-over to provide significant sensitivity.
[pA] [pA]
0.15 0.15
current
0.10 0.10
0.05 0.05
0.00 0.00
5 10 15 20 5 10 15 20
Time [min] Time [min]
<Splitless Injection>
[pA] [pA]
0.06 0.06
current
0.04 0.04
0.02 0.02
0.00 0.00
<Split Injection>
FID (Flame Ionization Detector), as one of these detectors, which is widely used for detection of hydrocarbons ensures
extraordinary sensitivity with less than 1.2 pg C/s MDL (Minimum Detection Limit). After conducting thousands times of
sequential tests for baseline noise and drift, our FID remains stable and reproducible data, which enables data reliability.
Chromatogram
Monitoring in
Real Time
YOUNG IN Chromass 7
GC/MS
ChroZen GC/MS is an innovative single quadrupole mass
spectrometer to carry out qualitative and quantitative analysis for
unknown or complex samples in trace level. With its standout ultra-
inert ion source called UEIS (Ultra Efficiency Ion Source), it minimizes
the contamination to ensure both ideal repeatability and sensitivity.
GC/VUV Detector
The VUV (Vacuum Ultra Violet) detector is a universal mass-sensitive
gas chromatography detector, which provides both qualitative
and quantitative data applying the fact that almost every chemical
compound including many isomers absorbs strongly in this
wavelength range (115 – 185 nm). The measured spectra can be
matched against an existing compound specific absorption cross
section library to rapidly identify the compounds (ASTM 8071
support).
Sulfur Analyzer
Sulfur Analyzer provides increased
sensitivity and selectivity with PFPD (Pulsed
Flame Photometric Detector) for the
analysis of sulfur compounds at trace levels
as well as the analysis method achieving
ASTM 6228.
YOUNG IN Chromass 9
Save Your Time in Laboratories
Liquid Autosampler
ChroZen PAL LSI
ChroZen PAL LSI (Liquid Sample Injection) System can reach any three-dimensional
position within its working space and is ideally suited to pick and place objects like
vials. It can inject from several sample containers into different inlets or transport
vials from a tray to a temperature controlled modules like the peltier stack for
cooling them down to 4°C.
YL3050A Autosampler
• The self-aligning “plug and play”: Easy positioning/Installation/re-positioning
4 (10 mL) or
Washig Vial 4 (2 mL) 6 (10 mL)
2 (100 mL)
Dual Injection
N/A Available Available
(In Sequence)
Integrated Bar
N/A N/A Available as Option
Code Reader
Sample
42 vials (20 mL) 14 vials (20 mL) 180 vials (10/20 mL)
Capacity
Oven Position 6 1 6
Syringe Volume
2.5 mL 2.5 mL 2.5 mL
(Standard)
Syringe Volume
1, 5 mL 1, 5 mL 1, 5mL
(Option)
YOUNG IN Chromass 11
Sample Preparation System
Lumin Purge and Trap Concentrator
The Lumin Purge and Trap Concentrator (PTC) is a sample preparation instrument
used to remove Volatile Organic Compounds (VOCs) out of aqueous and solid sample
types using Helium or Nitrogen.
ChroZen ATD
ChroZen ATD is an automated thermal desorption system which enhances productivity
by 50 sorbent tubes capacity and smart sequence overlapping function. With two-
stage desorption, it also utilizes versatile thermal desorption by concentrating volatile
and semi-volatile organic compounds collected on a sorbent tube into a focusing trap
to enable the analysis of VOCs at trace level with the superior sensitivity.
• List of Controllable Instruments: ChroZen GC, ChroZen • 21 CFR Part 11 Compliance: Management of user
GC/MS, YL6500 GC, YL6900 GC/MS, ChroZen UHPLC, accounts, audit trail and electronic signature
YL9100 Plus HPLC, YL9300 HPLC, YOUNG IN Chromass
• Simultaneous data acquisition from up to four
autosamplers
independent chromatographs: Each chromatograph
• MS Windows Compatibility: Vista, 7, 8, 10 can acquire data from up to 32 detectors.
• O
ptional Module
SST (System Suitability Test) MS Control
NGA (Natural Gas Analysis) DHA (Detailed Hydrocarbons Analysis)
PDA Extension Validation Kit
GPC Extension
GC - MS Data
Wiley Registry 12th WR12/NIST 20
Library NIST 2020
Edition GC-MS Total
Spectra 817,290 350,643 1,088,000
Chemical
785,061 350,643 1,056,000
Structures
Compounds 668,452 306,869 843,000
YOUNG IN Chromass 13
Gas Generator
Hydrogen Generator (NM-H2-Plus, PG-H2-Plus)
There are 2 types of hydrogen generators provided, which are NM-H2 Plus series and
PG-H2 Plus series to be used in the proper application depending on the purity of
hydrogen and the way of cartridge maintenance. Hydrogen generator eliminates dead
time for gas bottle changeover and the risk of explosion while providing enhanced
data reliability.
Customer Support
Useful Video
Materials
Application User Online
Support Workshop Remote
Support
Weekly SNS
Webzine Utilization
YOUNG IN Chromass 15
60, Anyangcheondong-ro, Dongan-gu, Anyang-si, Young In Chromass products are endorsed by
Gyeonggi-do, 14042, Korea Korean PPS(Public Procurement Service) in
recognition of their excellent technologies and
TEL : +82-31-428-8700 / FAX : +82-31-428-8787
the product quality.
E-mail : [email protected]
Homepage : www.youngincm.com