Rts820 Series
Rts820 Series
Rts820 Series
ru +7 (499) 643-33-80
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
CONTENT
FORWORDS ..................................................................................... 1
PRECAUTIONS: ............................................................................... 2
1. APPEARANCE AND FUNCTIONS ......................................... 3
1.1 APPEARANCE .............................................................................................................................................. 3
1.2 DISPLAY ........................................................................................................................................................... 4
1.3 KEYPAD............................................................................................................................................................ 4
1.4 SOFT KEYS ..................................................................................................................................................... 5
1.5 SYMBOLS ........................................................................................................................................................ 6
1.6 ILLUMINATION & SOUND .................................................................................................................... 7
1.7 AUTO POWER OFF.................................................................................................................................... 8
3 ROUTINE MEASUREMENTS.................................................23
3.1 CAUTIONS FOR DISTANCE MEASUREMENT: ................................................................... 23
3.2 EDM SETTING........................................................................................................................................... 23
3.3 HOT KEY....................................................................................................................................................... 24
3.3.1 Set the Height of the Target .............................................................................24
3.3.2 Set the Temperature & Pressure .....................................................................25
I
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
4. KEY ................................................................................36
4.1 SET UP A STATION WITH KNOWN POINTS ........................................................................... 36
4.1.1 Set up a Station with Known Coordinates......................................................36
4.1.2 Sight the Backsight by Entering the Azimuth Angle .....................................40
4.2 MULTIPLE POINT RESECTION ....................................................................................................... 42
4.3 QUICK STATION ....................................................................................................................................... 45
4.4 HEIGHT TRANSFER (DETERMINING STATION ELEVATION) ..................................... 47
4.5 CHECKING AND RESETTING THE BACKSIGHT DIRECTION ....................................... 49
5. KEY ................................................................................50
5.1 STAKE OUT ANGLE AND DISTANCE ........................................................................................... 50
5.2 COORDINATES STAKEOUT ............................................................................................................... 55
5.3 PARTLINE SO............................................................................................................................................. 57
5.4 REFLINE STAKEOUT............................................................................................................................. 59
5.5 GUIDE LIGHT.....................................................................................................................6 1
6. KEY ................................................................................63
6.1 DISTANCE OFFSETS............................................................................................................................... 63
6.2 MEASURING ANGLE OFFSETS ........................................................................................................ 64
6.3 TWO-PRISM POLE.................................................................................................................................. 66
6.4 +HA LINE ..................................................................................................................................................... 67
6.5 INPUT HD .................................................................................................................................................... 68
6.6 CALCULATE A CORNER POINT ...................................................................................................... 69
6.7 COLUMN....................................................................................................................................................... 70
6.8 EXTEND THE SLOPE DISTANCE .................................................................................................... 71
7. KEY.................................................................................73
7.1 2 POINT REFLINE ................................................................................................................................... 73
7.2 REFERENCE ARC .................................................................................................................................... 74
7.3 REMOTE DISTANCE MEASUREMENT ....................................................................................... 76
7.3.1 MimRadial..........................................................................................................77
II
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
V
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
FORWORDS
Thank you very much for purchasing the Ruide Total Station RTS-820 series!
This manual will give a detailed and complete instruction about this new type
total station. Please read it carefully before using the instrument.
1
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
PRECAUTIONS:
1. Do not collimate the objective lens directly to the sunlight without a filter.
2. Do not store the instrument in extremely high or low temperature, in order to
avoid the sudden or great change of temperature.
3. When the instrument is not in use, store it in the case and avoid shock, dust
and humidity.
4. If there is great difference between the temperature in work site and that in
store place, you should leave the instrument in the case till it adapts to the
temperature of environment.
5. If the instrument has not been used for a long time, you should remove the
battery for separate storage. The battery should be charged once a month.
6. When transporting the instrument should be placed in its carrying case, it is
recommended that cushioned material should be used around the case for support.
7. For less vibration and better accuracy, the instrument should be set up on a
wooden tripod rather than an aluminum tripod.
8. Clean exposed optical parts with degreased cotton or less tissue only!
9. Clean the instrument surface with a woolen cloth after use. If it gets wet, dry it
immediately.
10. Before opening, inspect the power, functions and indications of the
instrument as well as its initial setting and correction parameters.
11. Unless the user is a maintenance specialist, do not attempt to disassemble
the instrument by yourself even if you find the instrument abnormal.
2
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
5 6 7 8 9 10 11 12 13 14
3
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
1.2 DISPLAY
Power Switch Key ON
RTS-822R5
Number:S15000
Version:09.05.19
Display 1/5
HA# 30°21′50″
VA# 273°13′45″
SD# m
PT:RUIDE
HT: 1.000 m
● Confirm the battery power shown on the display. Replace it with another
charged battery or change it when battery level is low. Refer to section 2.3
“Battery Power Remaining Display”.
● The chart above is the display screen. It is possible that local software
versions are different from the basic version.
1.3 KEYPAD
4
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Illumination ON/OFF
5
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
1.5 SYMBOLS
According to different software versions, the symbols indicate specific working
status.
Key Meaning
, Please select via left/right key.
▲, ▼ To display each screen via up/down key.
Indicates that several pages are selectable. Press it to turn
,
the page.
Indicates that the telescope (alidade) is on Face1 or Face 2.
F1 Face 1 Measurement: the raster disc is on the left of
F1, F2 telescope when measuring.
F2 Face 2 Measurement: the raster disc is on the right of
telescope when measuring.
6
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Z Elevation coordinate
PT point
HT height
CD code
PPM atmospheric correction value
P1 Point 1
P2 Point 2
HI instrument height
BS backsight point
ST surveying station
1. A “#” behind those symbols means the automatic tilt
correct isn’t activated.
2. When a “d” displays in front of those symbols, it means it
is a difference value.
Press the illumination key ( ) to turn the LCD backlight ON and OFF.
Press illumination key for 1 second to open a 3-switch window described above.
Use the 3-switch window to adjust lighting, sound setting and contrast of the screen.
In the window opened as above, press [▲], [▼] (or press [1], [2], [3], [4], [5]
corresponding to the items) to choose the settings for switch. When an item is
selected, the function corresponding to the key can be launched ON/OFF by
pressing the corresponding number.
7
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Display 1/5
④ Press [3] or [▼] to move to [3] or [▼] HA# 30°21′50″
contrast item. Press [3] + VA# 273°13′42″
SD# m
continuously to adjust the contrast [3] PT:RUIDE
level. HT: 1.000 m
Display 1/5
⑤Press [4] or [▼] to move to laser [4] or [▼] HA# 30°21′50″
pointer item. Press [4] to turn on or + VA# 273°13′42″
SD# m
off the laser pointer. ※1 [4] PT:RUIDE
HT: 1.000 m
Display 1/5
⑥Press [5] or [▼] to move to laser [5] or [▼] HA# 30°21′50″
laser plummet item. Press [5] to + VA# 273°13′42″
SD# m
turn on or off the laser plummet. [5] PT:RUIDE
※2 HT: 1.000 m
RTS-820LX/RX/R5X total station Display 1/5
are equipped with guide light for HA# 30°21′50″
stake out. Press [6] to turn on the VA# 273°13′42″
SD# m
guide light. PT:RUIDE
HT: 1.000 m
3
※1, ※2 Laser pointer and laser plummet are optional for RTS-820R series.
8
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
9
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
② Turn the leveling screw C to move the bubble to the center of the circular vial.
② Rotate the instrument 90º (100g) around its vertical axis and turn the
remaining leveling screw or leveling C to center the bubble once more.
③Repeat the steps ①② for each 90º (100g) rotation of the instrument and
check whether the bubble is correctly centered in all directions.
2. Centering by using the optical plummet
1) Set tripod
Lift tripod to suitable height, ensure equal length of three legs, spread and
make tripod head parallel to the ground, and place it right above the
measurement station point. Prop up tripod on the ground and fix one leg.
2) Install instrument and collimate the point
Set instrument carefully on tripod, tighten the central connecting screw and
adjust optical plummet to make the reticle distinctly. Hold the other two unfixed
10
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
legs with both hands and adjust position of these two legs through observation
of optical plummet. As it approximately aims at the station point, make all three
legs fixed on the ground. Adjust three leg screws of the instrument to make
optical plummet collimate precisely to the station point.
3) Use circular vial to roughly level the instrument.
Adjust length of three legs of tripod; make the circular vial bubble of the
instrument in the middle.
4) Use plate vial to level the instrument accurately.
①Rotate the instrument horizontally by loosening the Horizontal Clamp Screw
and place the plate vial parallel to the line connecting leveling screw A and B,
and then bring the bubble to the center of the plate vial by turning the leveling
screws A and B.
②Rotate the instrument 90℃, make it perpendicular to the connecting line of
level screws A and B. Turn level screw C to make the bubble of the plate vial in
the middle.
5) Precisely centering and leveling
Through observation of optical plummet, slightly loosen the central
connecting screw and move the instrument evenly (Don’t rotate the instrument),
making the instrument precisely collimating to the station point. Then tighten the
central connecting screw and level the instrument precisely again.
Repeat this operation till the instrument collimate precisely to the
measurement station point.
Display 1/5
HA# 30°21′50″
VA# 273°13′42″
SD# m
PT: RUIDE
HT: 1.000 m
Note:
① The battery operating time will vary depending on the environmental conditions
11
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
such as ambient temperature, charging time, the number of times of charging and
discharging etc. It is recommended for safety to charge the battery beforehand or to
prepare spare full charged batteries.
② The battery power remaining display shows the power level regarding the current
measurement mode. The distance measurement mode consumes more power than
angle measurement mode, so the power enough for the latter is not sure applicable
for the previous one. Pay particular attention to this when switching angle
measurement mode to distance measurement mode, because insufficient battery
power might lead to interrupted operation.
● Before outdoor operation, battery power status should be well checked.
③ When the measurement mode is changed, the battery power would not
immediately show the decrease or increase. The battery power indicating system
shows the general status but not the instantaneous change of battery power.
12
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Mounting
Insert three anchor jaws into holes in tribrach and line up the directing stub with
the directing slot. Turn the locking knob about 180°clockwise and tighten the locking
screw with a screwdriver.
13
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
☆ If there is parallax when your eye moves up, down or left, right, it means the
diopter of eyepiece lens or focus is not well adjusted and accuracy will be influenced,
so you should adjust the eyepiece tube carefully to eliminate the parallax.
Input STN
①Make sure that the current ST: A
inputting mode is alphabet mode. If HI: 1.000 m
CD:RUIDE
not, press [MODE].
List Stac
Input STN
③Press [MODE] to shift the ST: RUIDE800 1
inputting mode to number inputting. [MODE] HI: 1.000 m
CD:RUIDE
List Stac
14
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input STN
[8] ST: RUIDE800 1
④Press [8] and [0]. ※1) [0] HI: 1.000 m
CD:RUIDE
List Stac
Input STN
②Press [ ] to move the cursor to ST: RUIDE800 A
the character that needs to be [ ] HI: 1.000 m
CD:RUIDE
edited. ※1)
List Stac
Input STN
New ST: RUIDE820 A
③Input new character. character HI: 1.000 m
CD:RUIDE
List Stac
Input STN
④Press [REC/ENT] to confirm. The ST: RUIDE820 A
cursor moves to next item. [REC/ENT] HI: 1.000 m
CD:RUIDE
List Stac
15
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
alphabetic, it is named by adding 1 to the end of the last letter. When the cursor is in
the PT field, there are several ways to specify a point or input coordinates. Here, take
station PtID for example.
Input STN
① Input PtID in PT item and press ST: AD1 1
[REC/ENT]. [REC/ENT] HI: 1.000 m
CD:RUIDE
List Stac
Input STN
③ Press [REC/ENT] to return to the ST: 1 1
screen. The point is called up. The [REC/ENT] HI: 1.000 m
CD:RUIDE
cursor moves to next item.
List Stac
Input STN
① Input PtID in PT item and press ST: AD2 1
[REC/ENT]. [REC/ENT] HI: 1.000 m
CD:RUIDE
List Stac
② When you input a new point N:
name or number, a coordinate input Input E:
Z:
screen appears. Enter the coordinated
PT:AD2
coordinate. After inputting one item, +
CD:
press [REC/ENT] to move to next
item. [REC/ENT]
16
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input STN
①In PT item, insert wildcard “*” Input [*] ST: * A
(Here take “*” for example), and + HI: 1.000 m
CD:RUIDE
press [REC/ENT] [REC/ENT]
List Stac
②Press up/down and [REC/ENT] MP,1,RUIDE
to select the point. [▲]/[▼] MP,2,CODE
CP.4,870
When [▲] or [▼] appears in the +
CP.5
list,left/right can turn the page. [REC/ENT] CP,6
SS,7,5841 ▼
N: 10.000 m
③When a point is select from the E: 10.000 m
Z: 10.000 m
list, the coordinate will be displayed
PT:2
on the screen.
CD:
17
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input STN
④Press [REC/ENT] to return. This ST: 1 1
point is called up. The cursor moves HI: 1.000 m
CD:RUIDE
to next item.
List Stac
Input STN
①Press [List] softkey when the ST: 1
cursor is in the PT field. [List] HI: 1.000 m
CD:RUIDE
List Stac
②PtID list is displayed. 1
Press up/down arrowhead to move [▲]/[▼] 1145
1204
the cursor to the point that you want + 1205
to use, and then press [REC/ENT]. [REC/ENT] 230
40 ▼
confirm.
④ A:
A: If the inputted PtID exists in N: 10.000 m
internal memory, its coordinate will E: 10.000 m
Z: 5.000 m
be displayed on the screen. Press
PT:1
[REC/ENT] to return.
CD: RUIDE
18
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input PT01
⑤Return to PT inputting screen. PT: 230 1
HT: 1.000 m
The cursor moves to next item.
CD:
List Stac
Input STN
①When the cursor is on PT field, ST: 1
press [Stac]. [Stac] HI: 1.000 m
CD:RUIDE
List Stac
1
②The stacks of the points are [▲]/[▼] BC
B:
B: If the inputted PtID does not
N:
exist, it is required to input E:
coordinate (as shown on the right). Z:
Input the coordinate and press PT:2
[REC/ENT] to move the cursor to CD:
the code item. Input the code, press
[REC/ENT] to save and quit.
19
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input PT01
⑤ Return to PT inputting screen. PT: BC1 1
HT: 1.000 m
Move the cursor to next item.
CD:
List Stac
The stack shows the last 20 point names used, in chronological order from last
used to first used. Stacks with the same type are covered.
Input PT01
① In PT item, press [ENT] directly PT: 1
HT: 1.000 m
without inputting its PtID. [ENT]
CD:
List Stac
Input PT01
③ After inputting, press [REC/ENT] PT: <Coordinate input> 1
HT: 1.000 m
to return. [ENT]
CD:
List Stac
Input P1
① Press [Meas] in PT inputting [Meas] P1: 1
screen. P2:
20
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input P1
④ The screen returns. The cursor P1: <Coordinate measured> 1
moves to next item. P2:
If there’s alignment data in internal memory, PtID can be input via chainage
number. Please refer to “7.7.8 Setting Station”.
The method to input code can be input manually, called up from list and stack.
The operational method is same as that of PtID inputting.
2.9 LEVELING
As the tilt sensor is activated, automatic correction of vertical angle for
mislevelment is displayed.
To ensure a precise angle measurement, tilt sensor must be activated. The
display can be used to fine level the instrument.
If the instrument hasn’t been leveled roughly, the screen displays that the
instrument is out of the automatic correction range, and that it needs to be leveled
manually. Please refer to “2.2 Instrument Setup” for detailed leveling instruction.
RUIDE Total Station RTS-820 Series compensates the vertical angle reading as
well as both vertical and horizontal angle reading due to inclination of the vertical axis
in the X direction and XY directions. (Dual axis compensation is just applicable for
RTS-820R3 series.
STEP OPERATION DISPLAY
Tilt: X
① Press to enter into
X:-0°50′21″
automatic compensation function. Y: Over
※1) X OFF
21
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
22
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
3 ROUTINE MEASUREMENTS
3.1 CAUTIONS FOR DISTANCE MEASUREMENT:
After setting up and switching on correctly, the Total Station is immediately ready
for measuring.
All shown displays are examples. It is possible that local software versions are
different from the basic one.
Example of a possible measuring display:
Display 1/5
HA# 30°21′50″
VA# 273°13′45″
SD: m
PT:RUIDE
HT: 1.000 m
23
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Rec: Enter, All, Meas. This mode controls the mode operation of [MSR1]/MSR2] in basic
measurement function.
If “Enter” is adopted, a screen of “Rec Pt” is displayed to inform the user to check and confirm
before data is recorded.
“All” is a quick shooting and recording mode. The instrument automatically records the point
using the default PtID, and then returns to the basic measurement screen.
“Meas” is the default measuring mode. After a measurement, the instrument stops in the BMS
and waits for you to press [REC/ENT] before recording the point.
※2) The measurement mode setting of [MSR2] is the same as it. When pressing [MSR1] or
[MSR2], the system activates the corresponding measurement mode to measure.
Input HT
② Press [1] to enter into HT setting
function. [1] HT: 1.000 m
Stac
Input HT
24
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Display 1/5
④ Press [REC/ENT] to return to HA# 280°56′10″
basic measurement screen. [REC/ENT] VA# 46°29′06″
SD#
PT:1
HT: 1.000 m
25
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
26
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Display 1/5
③The system starts the set target HA: 280°56′10″
set, and returns to BMS. VA: 46°29′06″
SD:
PT:1
HT: 1.000 m
※1)Type=prism/non prism/reflector sheet
Constant=-999~999mm
HT=-9999.999~9999.999mm
“HT” can be left blank in the target set (input the number beyond the max instrument height), the
current HT value is always applied to the measurement.
measurement screen.
OK
27
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Display 1/4
①Collimate to the center of target [MSR1]/ HA# 29°44′21″
prism, press [MSR1] or [MSR2]. [MSR2] VA# 265°20′53″
SD#
PT:1
HT: 1.000 m
Display 1/4
②While the instrument is taking a HA# 29°44′21″
measurement, the prism constant is VA# 265°20′53″
SD# <-30mm>
displayed in a small font. PT:1
HT: 1.000 m
③Display the result of First page:
measurement in four pages, Display 1/4
including all normal measure HA# 29°44′21″
functions such as measure of angle, VA# 265°20′53″
SD# 2.201 m
distance and coordinate, etc. PT:1
HT: 1.000 m
Second page:
Display 2/4
AZ# 29°44′21″
DSP HD# 2.274 m
VD# -0.185 m
or
PT:1
[▲]/[▼] HT: 1.000 m
Press [DSP] or [▲]/[▼] to view Third page:
each page.
Display 3/4
HL# 330°15′38″
*If the secondary distance unit is V%# -8.14%
Z# -1.185
set, another page will display.
PT:1
HT: 1.000 m
Fourth page:
Display 4/4
N# -1.974
E# -1.128
Z# -1.185
PT:1
HT: 1.000 m
To change the height of the target (HT), temperature, or pressure, press [HOT].
28
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Settings that relate to corrections (T-P, Sea level, C&R) are included in the job
settings. These settings are job-specific. Changing of any item will create a new job
or shut off all jobs.
The maximum capacity of RTS-820 Serial Total Station is defined by the data
type. Up to 10000 points can be collected at most.
Display 1/5
①In BMS press [ANG] to enter AZ: 30°21′50″
angle observation function. [ANG] HD: m
SD: m
PT:RUIDE
HT: 1.000 m
3.5.1 0SET
Press [1] to set HA as 0, and then return to basic measurement screen.
STEP OPERATION DISPLAY
29
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Display 1/5
③ Program returns to basic HA# 20°00′00″
measurement screen, and displays VA# 87°04′21″
SD# m
the horizontal angle just input. PT:RUIDE
HT: 1.000 m
※1) To enter 159°46′25″, type 159.4625.
HR X =HR N
HA=BS A Z + HR X (normalized)
30
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
RePt. N=00
HR∑ 0°00′00″
②System sets the initial value of HR HR X
as 0. - HA HOLD -
*Sight BS
Press [ENT]
③Sight the first target point which is Sight the RePt. N=01
used for repeat angle backsight HR∑ 0°00′00″
measurement. (i.e. Backsight), and + VA: 79°42′26″
HD:
press[ENT] [ENT]
*Sight FS
Press [Meas]/[ENT]
④Use the horizontal clamp screw RePt. N=01
and tangent to sight the second HR∑ 46°03′48″
target point (i.e. foresight), Here the Sight the VA: 85°02′36″
HD:
horizontal angle is accumulated. foresight
*Sight FS
To end repeat angle measurement, Press [Meas]/[ENT]
press [ESC].
⑤Press [ENT] to save the
RePt. N=01
horizontal angles. Screen returns to HR∑ 46°03′48″
the initial interface of repeat angle [ENT] HR X 46°03′48″
measurement. Repeat steps ③--⑤ - HA HOLD -
*Sight BS
to proceed this function as you
Press [ENT]
need.
When you have collected enough horizontal angle results, press [MSR1] or
[MSR2] to take a measurement to the foresight. The average horizontal angle is
displayed. This value is fixed until the process is finished or cancelled.
STEP OPERATION DISPLAY
31
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
RePt. N=03
HR X 46°03′48″
③Display the measuring result. HA# 46°03′48″
HD: 2.335 m
*Press [ENT] Rec
Record FS Pt. as CP
④Press [ENT] to record. [ENT]
32
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
※1)To measure the target, after collimating to the prism center, press [MSR1] or [MSR2].
※2) If you have already taken a distance measurement to the target, you can initiate F1/F2
averaging by flipping the telescope to the other face.。
3.5.5 Hold
This seccion explains how to hold the horizontal angle reading.
To hold the horizontal angle to the current value, press [5] or select Hold in the
Angle menu.
To set the horizontal angle to the displayed value, press [ENT].
To cancel the process and return to the basic measurement screen, press [ESC].
STEP OPERATION DISPLAY
HA Hold
③Press [5] to enter into angle hold HA: 60°00′00″
function. Use the horizontal clamp [5]
screw or horizontal tangent to sight * HA is hold
the target. Press [ENT]
Display 1/5
④Press [ENT] to set the horizontal [ENT] AZ: 60°00′00″
angle of the target. HD: m
SD: m
PT:RUIDE
HT: 1.000 m
33
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
A total of 256 quick codes can be assigned. Each code can be assigned a
unique one/ two/three digit numbers. If no numbers are allocated to the codes, the
code is selected in accordance with the order in which the codes were entered in the
code list (e.g.: 01->: first code in the code list. 10-> tenth code in the code list).About
editing Quick Code, please refer to “11.4.14.4 Add a code”; users can also use the
data transferring software provided by RUIDE to create and upload codes, please
refer to “Appendix A 3: Code List”.
Display 1/5
HA: 60°00′00″
VA: 107°42′33″
SD: m
PT:RUIDE
① In basic measurement screen, [MODE] HT: 1.000 m
press [Mode] to enter into Quick ↓
Code function.
CD: 1/5
HA: 60°00′00″
VA: 107°42′33″
SD: m
PT:1
HT: 1.000 m
Input the serial CD:10 1/5
②Input the serial numbers of Quick numbers of HA: 60°00′00″
Code, which should be Arabic Quick Code VA: 107°42′33″
SD: m
numbers, and then press [ENT]. +
PT:1
[ENT] HT: 1.000 m
③Program starts code searching to CD:10 1/5
search the quick coding in internal HA: 60°00′00″
memory. To find the quick coding VA: 107°42′33″
SD: m
corresponding to the code, press
PT:1
[MSR1], after measuring the result HT: 1.000 m
and Quick Code are displayed. If
the quick code corresponding to the
code doesn’t exist in internal
memory, it will display “Code no
exist” ※1)
34
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
※1) If no quick code is allocated to the codes, the code is numbered in accordance
with the order in which the codes were entered in the code list, so you can enter serial
numbers to call up quick codes.
※2) To quit Quick Code function, press [MODE] again.
35
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
4. KEY
36
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input BS PT
②There are two conditions: BS: 3 1
measuring and not measuring the HT: 0.000 m
CD:
backsight point.
Stac
Input BS PT
③If you intend to take a distance Enter the BS: 3 1
measurement to the BS, enter the height of HT: 1.500 m
CD:
height of target in the HT field. target
Stac
37
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
38
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input BS PT
③If not measuring the backsight BS: 3 1
point, press [ENT] directly. [ENT] HT: 0.000 m
CD:
Stac
④Sight the BS point in F1, and Stn Setup 1/2
press [ENT] to finish setting. AZ: 30°21′50″
If the horizontal circle is on Face-2, HD: m
SD: m
screen would display “Turn to F1”.
* Obs.BS [MSR]/[ENT]
As show in the right graph. Rotate
F2
the telescope and alidade, and sight
the BS point in Face-1.
*Turn to F1
39
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Backsight
① To enter the azimuth angle to the 1. XYZ
2. Angle
backsight point, press [2] in the [2]
Backsight screen.
40
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
41
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
-------------------Stn Setup-------------------
①In [Stn Setup] menu press [2] to 1. Known
start the resection. [2] 2. Rese.
3. QuickStn
4. Z Coord
5. BS Check
Enter the point Input PT01
②Enter the point name for the first name for the PT: 1
observation point (PT1), and press 1st HT: 0.000 m
CD:
[ENT]. ※1) observation
point List Stac
Enter the Input PT01
③Enter the target height and press target height PT: 1 1
[ENT]. + HT: 1.800 m
CD:
[ENT]
List Stac
42
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input PT02
⑦Enter the second point (PT2) and Enter the PT: 1 1
its height of target. Press [ENT]. second point HT: 1.800 m
CD:
name
List Stac
43
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
A:
RESE
⑨When the instrument has enough dHD: 0.002 m
data; it calculates the station (STN) dZ: -0.001 m
coordinates. As shown in the right
* Press [Rec] End
graph A. If more than 2 points are Add View Dsp Rec.
available, a standard deviation
B:
screen appears. As shown in the
RESE
right graph B.
dN: 0.005 m
dE: 0.003 m
dZ: -0.001 m
* Press [Rec] End
Add View Dsp Rec.
⑩ A:
A: To take measurements to Input PT04
strengthen geometry of the [Add] PT: 1
resection, press the [Add] softkey. HT: 1.800 m
CD:
List Stac
B:
B:To check the measurements to
each known point, press the View Obs. Value
1,
[View] softkey. Press [▲]/[▼] to [View]
5,
select point on the screen, and then 8,V
[ENT] to check the measurements Add Del
to each known point, ※2) ↓
You can delete poor observations or
dHA: 0°00′10″
add observation point. ※3) dVD: 1.590 m
dHD: 3.227 m
PT: 1
HT: 1.620 m
Add Del Dsp
C:
C:Press [Dsp] to switch the dialog
box of result. [Dsp] RESE
N: 50.002 m
E: 11.025 m
Z: -0.199 m
* Press [ENT] Next
Add View Dsp Rec.
44
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input STN
(11)Press [ENT] or [Rec.] to record [ENT] ST: 10 1
the station when the results are OK, or HI: 1.800 m
CD:
as shown in the right graph. [Rec.]
BS: 1
The “ST” column defaults to the last
List Stac
recorded PT+1.
Input STN
ST: 10 1
(12)BS defaults to the first observed HI: 1.800 m
CD:
point. To change the BS, press the
BS: 1
[Vary] softkey. Use [▲]/ [▼] to select [Vary]
Vary
point on the screen, and then press
[ENT].
Select BS Pt
1,
5,
8,V
45
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
②Input the point name of ST, and Input the point QuickStn
press [ENT]. defaults to the last name of ST ST: 1
recorded PT + 1, or ST + 1, + HI: 1.800 m
BS:
depending on the Split ST setting) [ENT]
AZ:
※1)
List Stac
QuickStn
④No default PT is assigned to the ST: 123 1
BS. Leave this field blank, or enter a HI: 1.800 m
BS:
BS point name.
AZ:
QuickStn
⑤The backsight azimuth (AZ) Enter azimuth ST: 123 1
defaults to zero, but you can change of BS HI: 1.800 m
BS:
this.
AZ:
46
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input PT
⑤Enter height of target prism, and Enter height of PT: 1 1
press [ENT]. target prism HT: 1.800 m
+ CD:
[ENT]
List Stac
47
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Stn Setup
⑩ The result dialog box is [OK] dHA: 0°00′00″
displayed, press [OK] to confirm. or dVA: -0°00′02″
dSD: 0.001 m
To remeasure, press [Abrt]. [Abrt]
* Press [ENT] Rec
Abrt CP OK
N: 10.000 m
⑾The updated station coordinates E: 10.000 m
Z: 6.180 m
are displayed, the height Z is
ST:1
updated. You can change the HI in
HI: 1.600 m
this screen.
※1) About method to input PtID, please refer to “2.8 METHOD TO INPUT PTID”.
48
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
●You must complete a station setup before you use the BS check function.
49
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
5. KEY
50
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
----------------------SO ---------------------
③After the program record STN
data, screen returns to SO main 1. HA-HD
2. XYZ
menu.
3. PartLine
4. Ref. Line
SO
⑥Sight the target and press [MSR1] [MSR 1]/ dHA 0°00′00″
or [MSR2] to start measuring. [MSR 2]
HD: 1.000 m
* Sight Press [MSR]
OK
⑦When the measurement is SO 1/8
completed, the differences between dHA 0°00′00″
the target position and the stakeout STP 0.000 m
IN 0.971 m
point are displayed. ※2), ※3) FIL 0.743 m
dHA: Difference in horizontal angle
* Press [ENT] Rec
to the target point
R/L: Right/Left (Lateral error)
IN/OUT: In/Out (Longitudinal error)
CUT/FIL: Cut/Fill
51
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
※1) If you press [ENT] without entering HA, the current HA is used.
※2) Once a measurement is taken; the Cut/Fill value and Z coordinate are updated as the VA is
changed.
※3) All observation results display in 8 pages, press [▼] or [DSP] to switch between display screens.
DISPLAY DESCRIPTION
52
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
SO 2/8
HA: 15°42′13″ This page displays the slant distance
VA: 20°03′05″ measurement of target prism. Press
SD: 2.359 m
[HOT] to enter into HOT Key menu.
*Press[HOT] Change
HT
Press ↓
---------------------- HOT Key ---------------
1.Input HT When the cursor is on “Input ht”,
2.Temp&Pres
3.TGT Press [ENT] to enter into Input HT
4.Note function.
Press[ENT]↓
Input HT
53
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
SO 4/8
HL: 344°17′46″
V%: 70.07% User can change the memory taken
Z: 1.236
up by display screen. Press [ ]/[ ],
* Press [DSP] 1Sec.
Display user-defined [▲]/[▼] to select, and use /
Press [DSP] for 1 second↓ softkey to change, press [ENT] or
<DSP1> <DSP2> <DSP2> [Save] to make the rectification valid.
HA AZ HL
VA HD V%
SD VD Z
* Change Use /
Save
SO 5/8
N: 3.302
E: 5.365 The screen stays on the measured
Z: 1.236
result,press [ENT] to display detailed
*press[MENU] /[DAT]
View Data information.
About the detailed description of data,
[Menu]→[Data]→[RAW Data] or press please refer to “11.4VIEWING
↓ RECORDS”.
RAW Data
CO,Use current ori ▲
SS,7888897,
CO,Temp:20.0 ℃ Pre
CO,Use current ori
Del Edit Srch
54
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
------------ SO ---------------------------------
①In SO menu, press [2] to enter 1. HA-HD
into coordinate stakeout function. [2] 2. XYZ
3. PartLine
4. Ref.Line
② A:
A: Input PT
Enter the point name that you want PT: 2 1
to stake and press [ENT]. After Rad:
CD:
finding the input point name,
program proceeds to procedure Fr/To List Stac
④. To display the coordinates, B:
press [ENT] to confirm.
Input PT
B: PT: 1
Specify the point by code or radius Rad: 12.000 m
from the instrument. (As shown in CD:
graph B).
Fr/To List Stac
C:
C:
Specify a stakeout list by range
Input PT range
input. To input points by range,
Fr: 1
press the Fr/To softkey in the PT To:
field., as shown in right graph C.
Enter the start point (Fr) and the end
List Stac
point (To).The last digit of point
name must be a number. If existing
points are found between Fr and To,
a point list is displayed, see ③.
MP,1,
③If several points are found, they MP,4
are displayed in a list. Then use MP,6
[ ]/[ ] and [▲]/[▼] to select MP,8
needed point, and press[ENT]. ※2)
Ctrl
55
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
N: 10.020 m
④Screen displays coordinates of E: 10.004 m
Z: 6.189 m
the selected point name., press [ENT]
PT:1
[ENT] to confirm.
CD:
List Stac
⑤The delta angle and the distance PT:1
to the target (HD) are shown. Rotate dAZ 123°41′23″
the instrument until the dAZ is close [MSR 1]/
HD# 7.071 m
to [MSR 2]
* Sight Press [MSR]
0°00'00", press [MSR1]/ [MSR2]. OK
dHA:Difference in horizontal angle
to the target point
HD:Distance to the target point
⑥After measuring, the deviation PT 1/8
value between measure point and dHA 0°00′00″
stakeout point is shown. ※1) STP 0.000 m
IN 3.971 m
dHA:Difference in horizontal angle FIL 0.743 m
to the target point
* Press [ENT] Rec
R/L Right/Left (Lateral error)
IN/OUT In/Out (Longitudinal error)
CUT/FIL Cut/Fill
⑦Ask the rodman to adjust the SO 1/8
target position. When the target is dHA 0°00′00″
on the intended position, the L 0.000 m
IN 0.000 m
displayed errors become 0 m. FIL 0.201 m
:moving towards to station
* Press [ENT] Rec
:moving away from station
SO 1/8
⑧When both R/L and IN/OUT dHA 0°00′00″
display 0m, it indicates the prism is L 0.000 m
IN 0.000 m
on the stakeout point. FIL 0.201 m
The fifth line shows the data of fill or
* Press [ENT] Rec
dig.
⑨After staking out, your can press N: 10.000 m
[ENT] to record the stakeout point. E: 10.000 m
Z: 6.180 m
PT defaults to the last recorded [ENT]
PT:221
PT+1, you can input code if
CD:
necessary. Press [ENT] to record List Stac
the point.
56
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
⑩ A:
A:After recording the point, the Input PT
display returns to the observation PT: 2 1
Rad:
screen. You’re your press [ESC], the
CD:
display returns to the PT/CD/R input
screen. If you entered the stakeout Fr/To List Stac
point using a single point name, PT B:
defaults to the last PT+1. MP,1,
B:If you selected a point from the MP,4
list, the display returns to the list, MP,6
MP,8
unless all points have been
selected. Press ESC] to return to Ctrl
the point input screen.
※1) Once a measurement is taken, the Cut/Fill value and Z coordinate are updated as the VA is
changed.
※2) If you have assigned a control job, and additional points are found in the control job, the Ctrl softkey
is displayed under the list.
※3)Use the Add Constant field in [MENU]→[3.Set]→[6.SO] to specify an integer that is added to the
point number being staked to generate a new number for recording the staked point.
For example, when you stake out PT3 with an Add Constant of 1000, the default number for SO record
is 1003.When there are letters in the point name, put the Add Constant after the letter.
For example: When you stake out AD12 with an Add Constant of 1000,the default number for SO
record is AD1012.
All observation results display in 8 pages: press [▼] or [DSP] to switch between
display screens. Detailed introduction please refer to “HA-HD SO”.
5.3 PARTLINE SO
This function divides the line between the instrument and the target by an input
span number. It then guides you to stake out the points, one by one.
For example, if you measure to the end point at 100 m from the instrument and
set the span total to 2, the following four points are calculated and can be staked.
57
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
------------------------ SO ----------------------
①In SO menu press [3] to enter into 1. HA-HD
PartLine SO function. [3] 2. XYZ
3. PartLine
4. Ref.Line
④The observation screen for the Sight the first PartLine <1/3>
first stake (from the instrument) stake out point HD: 0.667 m
appears. Sight the prism and press + L
OUT
[MSR1]/ [MSR 2]. [ENT]
Prev Next
58
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
PartLine <1/3>
⑧When both R/L and IN/OUT HD: 0.667 m
STP 0.000 m
display 0m, it indicates the prism is STP 0.000 m
on the stakeout point. * Press [ENT] Rec.
Prev Next
------------------------ SO ----------------------
①In [SO] menu press [4] to enter 1. HA-HD
into Ref.Line stakeout function. [4] 2. XYZ
3. PartLine
4. Ref.Line
59
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
60
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
61
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
When only seeing the yellow light, move the prism to the right
When only seeing the red light, move the prism to the left.
When seeing both lights blinking alternately, it means the prism is in the
correct line.
62
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
6. KEY
6.1 DISTANCE OFFSETS
63
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
64
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
④To take the angle offset, rotate the O/S Ang. 1/5
alidade and telescope. The HA# 25°09′01″
measured distance (HD) remains VA# 90°06′01″
SD# 3.971 m
unchanged.
Abrt OK
⑤To record the offset point, press HA: 25°09′01″
[OK], and otherwise press [Abrt]. VA: 90°06′01″
SD: 2.228 m
The XYZ data is also recalculated [OK]
PT:221
based on the new angle. In the
CD:
dialogue box of results calculated by List Stac
the program, press [ENT] Rec.
Display 1/5
⑥The display returns to basic HA# 107°00′00″
measurement screen. VA# 75°52′27″
SD#
PT:222
HT: 1.600 m
Display 1/5
①In basic measurement screen, [MSR1]/ HA# 1°00′56″
press [MSR 1] or [MSR 2]. [MSR2] VA# 94°26′10″
SD# 2.309 m
PT:222
HT: 1.600 m
② After taking a distance Display 1/5
measurement, rotate the alidade HA# 35°55′36″
and/or telescope. Press [DSP] or VA# 78°26′10″
SD# 2.309 m
[▼] to view other pages of the result.
PT:222
You can see that the coordinates HT: 1.600 m
are changed with the change of
angle.
Rec Pt
③Then press [ENT] to record the PT: 26 A
HT: 1.000 m
measured distance with the updated [ENT]
CD:
angle value.
List Stac
65
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
List Stac
Sample records
CO,2Prism O/S:
66
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
,P2-Tgt=2.000
P1-P2=5.000(5.005)
-------------------Offset -----------------------
①In [Offset] menu, press [4] to enter 1. O/S Dist
2. O/S Ang.
the line extension (+HA) function. [4]
3. O/S 2D
4. +HA Line
5. Input HD
②Sight the first prism (or target), Sight the first +HA Line <No. 1> 1/5
press [MSR1]/[MSR2]. prism HA# 15°42′13″
VA# 94°01′13″
+ SD#
[MSR1]/ * Sight Press [MSR]
[MSR2] OK
③Program enter measuring the +HA Line < No. 2> 1/5
second point automatically. Sight Sight the HA# 83°19′14″
VA# 91°11′47″
the second prism and press second prism SD#
[MSR1]/[MSR2]. + * Sight Press [MSR]
[MSR1]/ OK
[MSR2]
④Sight the alternative place on the +HA Line < No. 2> 1/5
same vertical line as the desired HA# 83°19′14″
VA# 91°11′47″
target point. SD# 1.847 m
* Sight <ALT> PT
OK
67
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
6.5 INPUT HD
This function is useful when the instrument is very close to the point and it is
difficult to take a measurement using the EDM.
STEP OPERATION DISPLAY
Input HD 1/5
②Turn the telescope in the direction HA# 83°32′21″
of the point that you want to store. VA# 92°28′56″
HD: 0.000 m
Input HD 1/5
HA# 30°21′50″
③Enter the HD and press [ENT]. Enter the HD VA# 115°52′45″
HD: 12.000 m
68
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
②Take a distance measurement to Sight the first CornerPt <No. 1> 1/5
the first prism on the wall. Press point HA# 86°20′55″
VA# 68°39′41″
[MSR1]/[MSR 2]. + SD#
[MSR1]/ * Sight Press [MSR]
[MSR2] OK
③Sight a second point on the same Sight a second CornerPt < No. 2> 1/5
wall and press [MSR1]/[MSR2]. point HA# 96°06′38″
VA# 56°36′52″
+[MSR1]/ SD#
[MSR2] * Sight Press [MSR]
OK
④Sight the third point on the Sight the third CornerPt < No. 3> 1/5
second wall and press [MSR point HA# 110°10′05″
VA# 52°00′41″
1]/[MSR 2]. + SD#
[MSR 1]/ * Sight Press [MSR]
[MSR 2] OK
⑤If the two walls are at right angles, CornerPt < No. 4> 1/5
press the Calc softkey to calculate HA# 110°10′05″
VA# 52°00′41″
the corner point by three points. SD# 6.526 m
If you take a measurement to a [Calc] * Press[MSR] or [Calc]
fourth point, the corner point can be Calc
calculated as the intersection of two
walls (P1-P2 and P3-P4).
69
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
6.7 COLUMN
STEP OPERATION DISPLAY
②If you have not taken a Sight any point HA# 47°42′13″
measurement to the column before on the surface VA# 94°01′13″
SD#
entering this function, a temporary of the column
HT: 1.000 m
measurement screen appears. + * Sight Press [MSR]
Sight any point on the surface of the [MSR1]/ HT OK
column and press [MSR1]/ [MSR 2]. [MSR2]
HA# 47°25′14″
③Press [ENT]. If you use a prism VA# 94°56′15″
SD# 3.635 m
attached to the surface of the
HT: 1.000 m
column for the distance * Input +SD/press[ENT]
measurement, press the +SD [ENT] +SD
softkey to eliminate the offset error Press+SD:
(from the attached point to the Column
measured surface of the prism) HA# 47°25′14″
VA# 94°56′15″
before you press [ENT].
SD: 3.635 m
+SD: 0.000 m
edge of the
column * Sight 1
Calc OK
70
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
N: 29.369 m
⑥In dialog box, if the result is [OK] E: 25.566 m
Z: -14.177 m
satisfactory, press [OK], otherwise or
Rd = 5.369 m
press [Redo]. [Redo]
Redo OK
⑦Enter a PT (and CD) value and Enter PT and Rec Pt
press [ENT], The target point is CD PT: 26 A
HT: 1.000 m
calculated and recorded as an SS +
CD:
record. [ENT]
List Stac
71
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
72
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
7. KEY
7.1 2 POINT REFLINE
InputP1
②Enter the first point for the P1: 1
reference line P1. ※1) Input P1 P2:
InputP2
③Enter the second point for the P1: 1 1
reference line. InputP2 P2:
73
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Rec Pt
P1: 11 1
⑥press [ENT] to record. [ENT] HT: 1.000 m
CD:
Arc Start
②Enter the start of the curve point Input P1 P1: 1
P1. ※1) AZ1:
Arc Start
③Enter the azimuth of its tangent Input AZ1 P1: 1 1
line (AZ1). AZ1:
*Tangent A2 of P1
74
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Define Arc
④Choose a method to define the 1. P2-AZ2
arc, as shown in the graph. 2. Rad-AZ2
3. Rad-Len
⑤ A:
A: Use P2-AZ2 to define arc. Define Arc
Input point name of P2 and azimuth P2: 1
of its tangent line (AZ2). ※2) AZ2:
B:Use Rad-AZ2 to define arc.
Input the radial and azimuth of its Meas List Stac
tangent line (AZ2). B:
In the radius (Rad) field, enter a Define Arc
positive value for a clockwise curve. Rad: 1
Enter a negative value for a AZ2:
counterclockwise curve. As shown
* Rad (-) Counter-cw.
in graph B.
Rad (+) Clockwise
C:
C:Use Rad-Len to define arc.
Define Arc
Input radial and arc length. Similarly,
Rad: 1
in the radius (Rad) field, enter a Len:
positive value for a clockwise curve.
Enter a negative value for a * Rad (-) Counter-cw.
Rad (+) Clockwise
counterclockwise curve. As shown
in graph C.
75
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
76
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
7.3.1 MimRadial
Measuring between the current and the first point measured
MimRadial 1/2
Sight the first rSD#
②Sight the first point and press point rVD#
rHD#
[MSR1]/[MSR2]. +
* Sight Press [MSR]
[MSR1]/
[MSR2]
MimRadial 1/2
③The distance from the station rSD# 2.287 m
point to the first point is displayed. rVD# -0.174 m
rHD# 2.280 m
* Sight Press [MSR]
* Press [ENT] Rec.
77
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
78
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
79
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
80
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
REM
HT: 0.000 m
②Enter the height of target HT. Enter the Vh:
height of target
* Input HT first
Stac
REM
HT: 1.620 m
④The measuring results are Vh: 1.620 m
displayed.
* Press [ENT] update HT
REM
⑤Loosen the vertical clamp, and Sight the target HT: 1.620 m
turn the telescope to aim at the point Vh: 3.572 m
target point. The difference in
* Press [ENT] update HT
elevation (Vh) is displayed.
REM
⑥You can press [ENT] to update HT: -1.977 m
the height of target. [ENT] Vh: 0.000 m
81
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
InputP1
②Input the first point to define the P1: 1
plane. InputP1 P2:
※1)
Meas List Stac
InputP2
③Input the second point on the P1: 1 1
vertical plane, and press [ENT]. InputP2 P2:
82
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
3/3:
V-PLANE 1/3
HA# 78°45′19″
VA# 162°30′26″
83
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
InputP1
P1: 1
②Input the first point to define the Input P1 P2:
P3:
slope plane.
Meas List Stac
InputP1
P1: 1 1
③Input the second point. Input P2 P2:
P3:
InputP1
④Input the third point on the plane. P1: 1 1
If press [2PT] here, the program will Input P3 P2: 2
P3:
define the plane by P1 and P2. ※1)
Meas 2PT List Stac
S-PLANE 1/3
⑤Once the plane is defined, the a: -9.220 m
calculated a and b values are b: 5.635 m
updated as you move the
* a:to P1 dist
telescope. No distance
b:to P1-P2 offs
measurement is required.
2/3:
a:Distance between P1 and the
S-PLANE 2/3
point that is perpendicular to the
N: -3.837 m
target point along the P1-P2 line
E: 11.933 m
b:Length of the perpendicular line Z: -1.702 m
from the target point to the P1-P2 * INT of collimator
line and plane is XYZ
3/3:
84
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
※1) If the plane is defined by two points, the vertical plane is the same as the plane used in the V-Pln
function, but the indicating factors are Sta and dZ, not a and b.
P3
b
P1
P2
a
7.7 ROADS
This program enables you to easily define a line or curve or spiral as a reference
for measurements and stake outs. It supports chainages, as well as incremental
stake-outs and offsets.
Before starting road design and stake-out, user should set job, station, and
orientation first.
Roads
1. HZ Alignment
2. VT Alignment
3. Stn Setup
4. Stake Out Roads
Start Pt 01
CH : 0.000
N : 0.000 m
E :
Serial number and the amount of present horizontal alignment are displayed on
the upper right corner of the screen.
The element of start point consists of the start chainage and E, N coordinate of
start point. Enter these details, and press [ENT] to display the main line inputting
screen.
85
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Define HZ AL 01
CH : 1.000 m
AZ : 0°00′00″
The screen displays: current chainage, the azimuth angle of the tangent on the
chainage, and the function key of the establishing new line. The system provides
four functions: defining line, curve, spiral, and point.
Select a function key, enter the detailed information of the chainage, the
alignment elements will be created. Press [ENT] to calculate the new chainage and
azimuth angle automatically and return to the alignment defining main menu. Now
other line type can be defined.
STEP OPERATION DISPLAY
Roads
②Select “1.HZ Alignment” to enter [1] 1. HZ Alignment
into define HZ Alignment function. + 2. VT Alignment
3. Stn Setup
[ENT] 4. Stake Out Roads
HZ Alignment
1. Define HZ AL
③Select “Define HZ AL”. [1] 2. Edit HZ AL
3. Receive HZ AL
4. Delete HZ AL
86
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Define HZ AL 01
⑤The display enters into the Define CH : 1.000
AZ : 0°00′00″
HZ alignment main menu.
Straight Line
When the start point or other line type is defined, user can define line. A line
consists of azimuth angle and distance. The distance value can not be negative.
STEP OPERATION DISPLAY
Define HZ AL 01
①In Define HZ AL screen press [Str] CH : 1.000
AZ : 0°00′00″
to enter into the straight line defining [Str]
menu.
Str Arc Trns Pt
Arc
87
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Press [ARC] in “Define HZ AL” menu to define the arc. A curve consists of arc
length and radius. The rule of radius value: along the forward direction of the curve.
When the arc turns right, the radius value is positive; while the arc turns to left, the
radius value is minus. The arc length can neither be negative nor longer than the
circumference.
STEP OPERATION DISPLAY
Define HZ AL 01
①In Define HZ AL screen press CH : 1.000
AZ : 0°00′00″
[Arc] to enter into defining arc [Arc]
screen.
Str Arc Trns Pt
Transition
In Define HZ AL screen press [Trns] to define transition. A transition consists of the minimum
radius and arc length. The rule of radius value is same as the rule of radius value. Similarly, the arc
length can’t be negative.
88
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Define HZ AL 01
①In Define HZ AL screen press CH : 1.000
AZ : 0°00′00″
[Trns] to enter into defining transition [Trns]
screen.
Str Arc Trns Pt
Transition 02
②Input radius and arc length, and Input radius Rad :
Len :
press [ENT] to record this data. and arc length
[ENT]
Point
In Define HZ AL screen press [Pt] to define point. A point element consists of coordinate, radius
and spiral factors A1 and A2. Radius, A1 and A2 can not be negative. As radius is entered, an arc
with specified radius inserted between current point and next point. As spiral factors A1 or A2 are
entered, a curve with specified length is inserted between line and arc.
Note: If user input A1, A2 from according to the lengths L1, L2 of spiral, the following
formulas are used to calculate A1 and A2.
89
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Define HZ AL 01
①In Define HZ AL screen press [Pt] CH : 1.000
AZ : 0°00′00″
to enter into defining point function. [Pt]
Input N, E Pt 02
②Input N and E coordinates, radius coordinates, N : 0.000 m
E : 0.000 m
and A1, A2, then press [ENT]. radius and A1,
Rad: 0.000 m
A2 A1 : 0.000
[ENT] A2 : 0.000
Define HZ AL 02
③The display returns to the CH : 21.000
AZ : 100°00′51″
alignment defining main menu.
Soft keys:
[Strt]:Go to the beginning of the file, and displays the first alignment data.
[End]:Go to the end of the file, and displays the last alignment data.
[Prev]:Display the previous point data.
[Next]:Display the next point data.
It is possible to edit data by using the function keys above. After entering the
data to be edited, press [ENT] to record the edited data and enter into the inputting
screen of next point. To quit without saving data, press [ESC].
HZ Alignment
① In HZ Alignment select “Edit HZ [2] 1. Define HZ AL
AL”. 2. Edit HZ AL
3. Receive HZ AL
4. Delete HZ AL
90
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Start Pt 01/05
②Screen displays the start point CH: 10.000
N : 10.000 m
data. Press [Next] softkey to find [Next]
E : 10.000 m
the alignment data needed to edit.
End Next
Straight
③Input the new data and press Input new data 02/05
AZ : 30°00′10″
[ENT]. + Len : 10.000 m
[ENT]
7.7.3 Receive HZ AL
STEP OPERATION DISPLAY
HZ Alignment
①In HZ Alignment select “Receive 1. Define HZ AL
HZ AL”。 [3] 2. Edit HZ AL
3. Receive HZ AL
4. Delete HZ AL
②Press [Comm] to set Receive HZ AL
communication parameter, making
the parameter consistent with the
setting in communication software.
If not transmit, press [Abrt]. [Comm] Abrt Comm Strt
Press [Comm ]:
Press [▲]/[▼] to move cursor to <Comm >
each parameter, press [ ]/[ ] to Baud:1200
select options of each item. After Data.L:8
finishing setting, press [ENT]. Parity:None
Stop :1
Receive HZ AL
91
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
HZ Alignment
①In HZ Alignment select “Delete 1. Define HZ AL
HZ AL”. [4] 2. Edit HZ AL
3. Receive HZ AL
4. Delete HZ AL
Abrt OK
92
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Roads
①In Roads menu select “2.VT 1. HZ Alignment
Alignment” to enter into define VT [2] 2. VT Alignment
3. Stn Setup
Alignment function. 4. Stake Out Roads
VT Alignment
1. Define VT AL
②Select “Define VT AL”. [1] 2. Edit VT AL
3. Receive VT AL
4. Delete VT AL
Input Define VT AL 01
③Input chainage, elevation and chainage, CH: 10.000
ELEV : 20.000 m
length, then press [ENT]. elevation and
Len : 0.000 m
The length of start point and end length
point must be 0. +
[ENT]
④At the bottom of the screen Define VT AL 01
“Complete” displays, saving this CH : 0.000
ELEV : 0.000 m
alignment data, the display returns
Len : 0.000 m
to Define VT AL screen to continue
inputting the next alignment.
93
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
VT Alignment
① In VT Alignment select “Edit VT [2] 1. Define VT AL
AL”. 2. Edit VT AL
3. Receive VT AL
4. Delete VT AL
VT Alignment
①In VT Alignment select “Delete VT [4] 1. Define VT AL
AL”. 2. Edit VT AL
3. Receive VT AL
4. Delete VT AL
Abrt OK
94
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Roads
①In Roads menu select“3.Stn [3] 1. HZ Alignment
Setup”. 2. VT Alignment
3. Stn Setup
4. Stake Out Roads
95
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input STN
④In OF item input the offset of the Input Offset CH: 100.000
chainage to center line. And press + OF: 0.000 m
HI: 0.000 m
[ENT]. [ENT]
96
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
In the process of stake-out, user should first stake out points on the central line,
then the featured points on both sides.
The method to stake out alignment is similar to that of point stake-out, with 3
methods available:
Take points on the central line for example.
STEP OPERATION DISPLAY
Roads
①In Roads menu select “4. Stake [4] 1. HZ Alignment
Out Roads”. 2. VT Alignment
3. Stn Setup
4. Stake Out Roads
②Displays the alignment stake-out StartC:
data. Input start chainage, chainage Incre.:
increment, and the horizontal O/S L:
O/S R:
distance between side chainage
dVD L:
point and central line. Height
dVD R:
distance is required if fill/dig data is Input data
to be staked out. +
O/S L: Horizontal distance between the left [ENT]
chainage point and central line.
O/S R: Horizontal distance between the right
chainage point and central line.
dVD L: Height difference between the left
chainage point and central line
dVD R: Height difference between the right
chainage point and central line.
97
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
98
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
LOFS:This key is used to stake out left chainage. Press it to display the offset
and the height difference of the left chainage.
ROFS:This key is used to stake out right chainage. Press it to display the offset
and the height difference of the right chainage.
+CHG:The key is used to increase the chainage.
-CHG:The key is used to increase the chainage.
99
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
The fill/dig data can be entered through left and right slopes. In terms of fill/dig,
use positive symbol to input the required slope, the software selects an appropriate
slope in the list according to the actual position of the point.
Dig/fill is decided via the estimated height of hinge point. If the height is above
the hinge point, the dig slope is used; otherwise the fill slope is used.
100
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
CH: 1.000
①In the Stake-out main menu, input O/S: 0.000 m
(or select) the side chainage to be [MENU] dVD: 0.000 m
* Press [MENU] Slope SO
slope staked out. Press [MENU] to
start. LOFS ROFS +CHG -CHG
Slope SO
②Input the ratio of left and right Input slope ( 1:N )
slopes to be filled (or digged). After + Cut L: 0.000
Fill L: 0.000
finishing inputting one item, press [ENT]
Cut R: 0.000
[ENT].
Fill R: 0.000
101
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
102
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
8. KEY
Display 1/5
①In basic measurement screen, AZ# 280°56′10″
press [5] (Code) key. [5] HD# 46°29′06″
SD#
PT:1
HT: 1.000 m
InputCod
②A window for entering the A
feature code appears. CD:
List Stac
③※1) A:
A:Input the CD manually. The InputCod
input code will be entered into Stac A
in chronological order. CD: RUIDE
List Stac
B:
B:Select code from [List] window AD
to input. To add, delete or edit code 1
3
in the List, please refer to “11.4.14
ER
Point Name List and Code List” B
D
C:Select code from [Stac] to input.
C:
Any place to input code manually
LIBA
can realize code Stac. The stack XIEPO
shows the last 20 point names LUDENG
DUIDEYIQ
used, in chronological order from LUBIAO
last used to first used. FANGW
103
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Display 1/5
AZ# 280°56′10″
④press [ENT] to return to BMS. [ENT] HD# 46°29′06″
SD#
PT:1
HT: 1.000 m
Rec Pt
⑤Press [Rec/Ent] to see if the PT: 26 A
HT: 1.000 m
default code is the setting you just
CD: RUIDE
do.
List Stac
※1) About method to input Code, please refer to “11.4.14.4 Add a Code”.
104
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
9. KEY
When you press [DAT] in the basic measurement screen or in observation
screens in functions such as Stakeout, 2Pt RefLine, etc, the data in the current job is
displayed.
Hold [DAT] for one second in the basic measurement screen or an observation
screen to display the Data Type screen. Through this screen you can change the
type of data that is assigned to [DAT].
●To change the type of data that is assigned to [DAT], go to [MENU] →[6.1
Sec.]→[5.Data]
●For more information, see “11.4 VIEW RECORDS”.
105
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
10. / KEY
If you use a certain function frequently in the field, you can assign it to the
[USR1] or [USR2] key. Whenever you press a [USR] key, the function which is
predefined is activated directly.
The following functions can be assigned to the [USR] keys:
Input HT
BS Check
TGT
Cogo→
Offset→
Program→
Temp&Press
Note
Point Laser
Direction Laser
(none)
STEP OPERATION DISPLAY
Display 1/5
③The screen returns to basic AZ# 280°56′10″
measurement. HD# 46°29′06″
SD#
PT:1
HT: 1.000 m
106
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
※1) The current predefined function is indicated by an asterisk (*) beside the function name.
※2) Once you have defined a function to a [USR] key, it is activated directly whenever you press that
[USR] key in the basic measurement screen.
107
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
11.1 JOB
--------------- Menu-----------------------
①Press [Menu] key, a screen 1.Job 6.1 Sec.
2.Cogo 7. Adjust
shows as the right graph. [Menu]
3.Set 8.Time
4.Data 9.Format
5.Comm 10.Info
JobMgr.
②Press [1] to open the Job * RUIDE 07-01-20
@ MQ 07-01-25
Manager. ※1) [1]
RTS800 07-01-25
SURVEY 07-01-25
New Del Ctrl Info
JobMgr.
②Select the item by [▲]/[▼], and * RUIDE 07-01-20
@ MQ 07-01-25
then press [Ent] to open the job. [▲]/[▼]
RTS800 07-01-25
※2) SURVEY 07-01-25
New Del Ctrl Info
Display 1/5
③Program sets the item as current HA# 20°00′00″
item, and returns to basic VA# 87°04′21″
SD# m
measurement screen. PT: RUIDE
HT: 1.000 m
※1)If there are no job stored, the CreatJob screen appears.
※2)When you open a job, all job settings are automatically changed to match those used in the opened
job.
108
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Job Mgr.
①Press [New ] in the job list. [New] * RUIDE 07-01-20
@ MQ 07-01-25
RTS800 07-01-25
SURVEY 07-01-25
New Del Ctrl Info
Job Settings
The following 12 settings are set when a job is created, and they can’t be changed. It
is different from other temporary settings. It ensures that the data in a job is correctly
stored in the database and that all necessary corrections are applied when you store
each record.
Item Option
Scale 0.99000~1.01000
T-Pcrn. ON/OFF
SeaLevel ON/OFF
C&R crn OFF/0.14/0.200
Angle DEG/GON/MIL
Dist Meter/USA Feet/USA Inch/IntlFeet/IntlInch
Temp ℃/ ℉
Press hPa/mmHg/inHg
VA 0 Zenith/ Vertical/Vert±90
AZ 0 North/ South
Order NEZ/ENZ
HA Azimuth/0 to BS
109
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
To change the setting in the selected field, press [ ]/[ ]; To move between fields,
press [▲]/[▼]. Alternatively, to move to the next field, press [Enter].
Create a new job automatically while pressing [Enter] in the last field.
Job Mgr.
①In the job list,move the cursor to * RUIDE 07-01-20
@ MQ 07-01-25
the job that you want to delete by [▲]/[▼]
RTS800 07-01-25
[▲]/[▼]. SURVEY 07-01-25
New Del Ctrl Info
Del Job
②Confirm the job that you want to Job: RTS800
delete as right screen.
* Sure?
Abrt OK
Job Mgr.
①Highlight the job that you want to * RUIDE 07-01-20
@ MQ 07-01-25
use as a control job by using by [▲]/[▼]
RTS800 07-01-25
[▲]/[▼]. SURVEY 07-01-25
New Del Ctrl Info
Ctrl job<ON>
②Press [Ctrl]. A confirmation screen Job: RTS800
appears. [Control]
110
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Job Mgr.
①Highlight the job that you want to [▲]/[▼] * RUIDE 07-01-20
@ MQ 07-01-25
display the information by pressing
RTS800 07-01-25
[▲]/[▼]. SURVEY 07-01-25
New Del Ctrl Info
Job Info
②The Job Info screen shows the Job: RTS800
number of records in the job while [Info] Rec:1
Creat:2007-01-25
pressing [Info].
111
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
------------------- Menu----------------------
①In the [Menu], press [2] or 1.Job 6.1 Sec.
2.Cogo 7. Adjust
([▼]+[Enter]). [2]
3.Set 8.Time
4.Data 9.Format
5.Comm 10.Info
--------- Cogo---------------------------------
1. Inverse
2. AZ&Dist
②Display the Cogo menu.
3. Area
4. LineOff.
5. InputXYZ
-------- Inverse------------------------------
1. PT-PT
2. 3PT Ang.
③Press [1] entering PT-PT menu. [1]
Input P1
④Select “PT-PT”, pressing the key
[1]. [1]
P1: 1
P2:
Meas Data List Stac
⑤Input the name of P1. The way to A:
input: Input P1 N: 10.000 m
A:
Input a point name which exists in E: 10.000 m
Z: 10.000 m
the memory. The system calls it
PT:2
up automatically.
CD:
B:
B:The system requests to enter the N:
information of the point if the point E:
doesn’t exist. It will return after the Z:
point is recorded. PT:2
CD:
112
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
D: D:
By pressing [MSR], as the D graph HA# 32°05′34″
shows. Press [MSR1] or [MSR2] to VA# 22°26′25″
SD#
measure a point as the first point of
HT: 1.000 m
the line.
*Sight Press [MSR]
HT OK
E: E:
Press [list] to use the point in the MP,1,
memory. MP,2
CP.4
To select the point, use the [▲], [▼] CP.5
key and [ENT] key. CP,6
If the ▲or ▼ appears in the list, turn SS,7,5841 ▼
Input P2
113
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
※1)Gd:Grade (HD/VD)
V%:100/Gd
rSD:Slope distance PT1 to PT2
11.2.1.2 3PT Angle
The 3pt angle calculates the angle between two lines defined by three points.
PT1 is the base point. Two lines are to be defined by P2 and P3, both from P1.
STEP OPERATION DISPLAY
------------- Inverse----------------------------
①Press [2] or select [3Pt Angle]in [2] 1. PT-PT
2. 3PT-Angle
the Inverse menu.
Inp basePT
②Input the name of base point P1,
and press [Ent]. About the input Input P1
P1: 1
method, see step ⑤ in “PT-PT”. P2:
P3:
Meas Data List Stac
Inp dir PT
③Enter the second point (P2) to
define the baseline (P1-P2), and Input P2
P1: 1 1
press [ENT]. P2:
P3:
Meas Data List Stac
Inp dir PT
④Enter the third point (P3) to define
the second line (P1-P3). Press Input P3
P1: 1 1
[ENT]. P2: 2
P3:
Meas Data List Stac
3PT- Angle 1/2
⑤Display the result of the 3PT AZ: 45°00′00″
Angle. Press [Dsp] to switch HD1: 2.000 m
between 2 pages. HD2: 2.828 m
114
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Page 2:
3PT Ang. 2/2
HD3: 2.000 m
*HD1=P1-P2 HD
HD2=P1-P3 HD
HD3=P2-P3 HD
End Dsp Next
⑥To continue 3 Pt. Angle function,
press [Next]; To quit, press [End],
screen returns to Inverse menu.
11.2.2.1 AZ+HD
STEP OPERATION DISPLAY
---------------- Cogo-------------------------
①In Cogo menu press [2] (or [▼] + 1. Inverse
2. AZ&Dist
[ENT]) to enter the AZ&Dist menu. [2]
3. Area
4. LineOff.
5. InputXYZ
Input PT
③Input point name of base PT and
1
press [ENT]. About method to input, Input P1
PT:
see “PT-PT” step ⑤.
Meas Data List Stac
Input AZ
④Input azimuth, horizontal distance
(HD) and vertical distance (VD) then Input HD, dVD AZ:
HD:
press [ENT].
dVD:
115
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
11.2.2.2 Store
Store function calculates a new point based on the two defined points and angle,
horizontal and vertical distances from the line defined by those two points.
STEP OPERATION DISPLAY
Input P1
②Input the point name of P1 and
press [ENT]. About method to input, InputP1
1
see “PT-PT” step ⑤. P1:
P2:
Meas Data List Stac
Input P2
116
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Input P2
⑥Screen returns to the point input
screen. P1 (base PT) defaults to the
1
previously recorded PT. P2 defaults P1: 9
to the previous P1. P2: 1
Meas Data List Stac
⑦Enter the plus-minus angle, Input+AZ, HD, Input+AZ
horizontal distance, and vertical dVD
distance from the baseline defined + +AZ:
HD:
by P1-P2, press [ENT]. [ENT]
dVD:
※1) To continuously calculate a new point, enter +Ang, HD, and dVD from the previous bearing line.
This is a convenient way to enter Store points.
-------- Cogo-----------------------------------
①In Cogo menu press numeric key 1. Inverse
2. AZ&Dist
[3] (or use [▼] + [ENT]) to enter into [3]
3. Area
Area calculating function. 4. LineOff.
5. InputXYZ
②Input the first point and press Input the first Points 000
[ENT]. In the upper right corner of point 1
the screen, a counter indicates how + PT:
* Press [MEMU] View
many points you have entered. [ENT]
About method to input, see “PT-PT” Meas List Stac
step ⑤.
117
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
------------- Cogo------------------------------
①In Cogo menu press numeric key 1. Inverse
2. AZ&Dist
[4] (or use [▼] + [ENT]) to enter into [4]
3. Area
line and off function. 4. LineOff.
5. InputXYZ
InputP1
②Enter the base point (P1). About
method to input, see “PT-PT” step Enter P1 1
P1:
⑤. AZ:
P2:
Meas Data List Stac
③ A:
InputAZ or P2
A:Input the AZ bearing. InputAZ or P2
1
P1: 1
AZ:
P2:
118
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
B:
InputAZ or P2
B:Skip AZ item, enter a value in P2
field to specify a azimuth bearing.
P1: 1 1
AZ:
P2:
Meas Data List Stac
LineOff.
119
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
----------- Cogo--------------------------------
①In Cogo menu press key [5] (or 1. Inverse
2. AZ&Dist
use [▼] + [ENT]) to manually enter [5]
3. Area
the XYZ coordinates. 4. LineOff.
5. InputXYZ
Input N:
②Enter the coordinates using the coordinates E:
Z:
numeric keys. To move to the next +
PT:10
field, press [ENT] or [▼] in a field. [ENT]
CD:
11.3 SETTINGS
STEP OPERATION DISPLAY
---------------------- Menu----------------------
①In [Menu], press numeric key [3] 1.Job 6.1 Sec.
2.Cogo 7.Adjust
(or use [▼] + [ENT]) to enter into [3]
3.Set 8.Time
setting function. 4.Data 9.Format
5.Comm 10.Info
②The setting menu displays. Use ------------- Settings---------------
[▲]/[▼] + [ENT] or numeric key to 1. Angle 6.SO
2.Dist. 7.Unit
select the item which needs to be [1]
3.XYZ 8.Record
set. (Here take angle setting as 4.Power 9.Other
example.) 5.Comm
<Angle>
③Use [▲]/[▼] to move to items that VA0:Zenith
need to change be changed. [▲]/[▼] Min Ang:5″
HA:Azimuth
120
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
<Angle>
④Press [ ]/[ ] to change the [ ]/[ ] VA0:Zenith
settings, and press [ENT]. Min Ang:5″
HA:0 to BS
In the following form, the items in “ ” can’t be changed once a job is created.
Item options
VA0:Zenith/Vertical/Vert±90
Min. Ang:1″/5″/10″
Angle HA:Azimuth/0 to BS
When this field is set to Azimuth, the horizontal angle (HA) that is displayed and
recorded is in Azimuth value.
When this field is set to 0 to BS, HA is in HA zero to BS value.
Scale: Numeric value between 0.990000 and 1.010000
T-P crn:ON/OFF
Dist. SeaLevel:ON/OFF
C&R crn:OFF/0.14/0.200
Max Dist:2000m/5000m (Select max range of laser distance measurement,
only for reflectorless total station.)
Order:NEZ/ENZ
XYZ Marker:NEZ/XYZ/YXZ
AZ 0:North/South
121
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Press:hPa/mmHg/inHg
Store DB:RAW+XYZ/RAW/XYZ
This setting determines whether raw and/or coordinate data is stored when you
Record record SS, CP, or SO records in the Basic Measurement Screen (BMS) or
Stakeout screen.
REC Data:MEM./COMM
Set this item to COM to output data on the COM port. The data is not stored to
the job file.
XYZ Dsp:Quick/Normal/Slow/Enter
Defines speed to move to the next screen after showing XYZ of the input PT.
2nd Unit:Meter/USA Feet/USA Inch/IntlFeet/IntlInch/None
Other Beep:ON/OFF
Split ST:ON/OFF
You can separate the point numbers of station points from other record type
point numbers. If you set the Split ST ON, you can enter single ST number in an
additional setting screen. Or you can press [ENT] to use default point name.
InputCod:ALPH/NUM
User Information:Enter your information up to 20 characters.
122
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
-------------- Menu----------------------
①In [Menu] press numeric key [4] 1. Job 6.1 Sec.
2.Cogo 7.Adjust
(or use [▼] + [ENT]) to enter into [Menu]
3.Set 8.Time
data function. 4.Data 9.Format
5.Comm 10.Info
123
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
11.4.1.1 ST Records
ST (station) records contain “ST”, “HT”, “BS” and “AZ”. Press [Dsp] to view XYZ
coordinates.
●When you assign a new ST point name in Stn Setup > QuickStn, the coordinates of
the station is recorded as (0, 0, 0).
11.4.1.2 SO Records
SO:Stakeout shots. These are shots recorded in stakeout functions. Press [DSP] to
switch between the screens.
●dN/dE/dZ store the difference between the stakeout shot’s actual position and its
planned position.
Del
124
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
RAW Data
F1,10, ▲
F2,10,
CP,9,V
①In the RAW Data screen, use
SS,5
[▲]/[▼] to highlight the record that [▲]/[▼] Del Edit Srch
you want to delete. (Or in data +
Press [ENT]:
screen which appears after pressing [Del]
HA: 44°59′52″
[ENT].) Press [Del]. VA: 102°26′43″
SD: 3.345 m
PT: 5
HT: 1.000 m
Del Edit Dsp
Delete RAW Data
②To delete data, press [OK] or [OK] SS,5,
[ENT]. or
Not to delete, press [CE]. [ENT] * Sure?
CE OK
RAW Data
③The system executes the ST,3
selected operation, and returns to F1,10, ▲
F2,10,
RAW Data screen.
CP,9,V
Del Edit Srch
125
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
RAW Data
F1,10, ▲
F2,10,
CP,9,V
①In RAW Data screen use [▲]/[▼] [▲]/[▼]
SS,5
to highlight the record that you want + Del Edit Srch
to edit. (Or in data screen which [Edit]
Press [ENT]:
appears after pressing [ENT].)
HA: 44°59′52″
Press [Edit]. VA: 102°26′43″
SD: 3.345 m
PT: 5
HT: 1.000 m
Del Edit Dsp
PT:
②Input the new data manually, or Input new data HT:
CD:
select data from [List] or [Stac], and +
* Amend & press [ENT]
then press [ENT]. [ENT] List Stac
RAW Data
①In RAW Data screen, press [Srch] F1,10, ▲
[Srch]. F2,10,
CP,9,V
SS,5
Del Edit Srch
126
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
List Stac
A:
A:
Search RAW Data
To find a point by name, enter the
name in the PT field and press Type:All
[ENT] twice. PT: 9
HT:
List Stac
B:You can use the wildcard (*) in B:
PT or CD field, for example: Input Search RAW Data
Type:All
30*, you can find 300、301, 302,
PT: *
3000A, 3010, etc. HT: *
List Stac
C:To search by point type, press C:
[▲] to move to the Type field and Search RAW Data
Type:All
use [<] or [>] to change the selected
PT:
point (All/ST/SS/SO/CP/CO/MLM). HT:
※1)
③Detailed data for the selected RAW Data
record appears. Press [ESC] to SS,10, ▲
return to the list. Press [Dsp] to SS,10,
SS,9,V
change the fields shown.
SS,5
※2), ※3) Del Edit Srch
※1) If you select a type in the Type item, you do not have to enter a value in the CD item. Press [ENT]
in the PT item to start the search.
※2) If more than one point matches the search criteria, the matching points are displayed in a list. Use
[▲]/ [▼] to highlight the point you want to use. Then press [ENT] to select it.
※3) If no point matches the specified criteria, “PT Not Exist” displays. Press any key to return to the
data screen.
127
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
XYZ Data
SS,10, ▲
MP,10,
SS,9,V
①In XYZ Data screen, use [▲]/[▼] [▲]/[▼]
MP,5
to highlight the record that you want + Del Edit Srch Inp.
to delete. (Or in data screen which [Del]
Press [ENT]:
appears after pressing [ENT]), press
HA: 44°59′52″
[Del]. VA: 102°26′43″
SD: 3.345 m
PT: 5
HT: 1.000 m
Del Edit Dsp
128
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Delete XYZ
②To delete data, press [OK] or [OK] SS,5,
[ENT]. or
Not to delete, press [CE]. [ENT] * Sure?
CE OK
XYZ Data
③The system executes the SS,10, ▲
selected operation, and returns to MP,10,
SS,9,V
XYZ Data screen.
MP,15
Del Edit Srch Inp.
11.4.7 Edit Coordinate Data
STEP OPERATION DISPLAY
XYZ Data
SS,10, ▲
①In XYZ Data screen, use [▲]/[▼] [▲]/[▼] MP,10,
SS,9,V
to highlight the record that you want +
MP,5
to edit. (Or in data screen which [ENT] Del Edit Srch
appears after pressing [ENT]), press
Press [ENT]:
[Edit].
N: 54697561.386
E: 58974652.011
Z: 553.011
PT: 5
CD: RUIDE
Del Edit
②You can edit PT, CD and N: 0.000 m
coordinate data. Input new data E: 0.000 m
Z: 0.000 m
Input the new data manually, and +
PT: 5
press [ENT]. [ENT] CD:
129
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
XYZ Data
SS,10, ▲
①In XYZ Data screen, Press [Srch]. [Srch] MP,10,
SS,9,V
MP,5
Del Edit Srch Inp.
②Input the search criteria. Search XYZ
Type:All
PT:
CD:
List Stac
A: A:
To find a point by name, enter the Search XYZ
name in the PT field and press Type:All
[ENT] twice. PT: 9
CD:
List Stac
B:
Search XYZ
B:You can use the wildcard. (*) in Type:All
PT or CD field, for example: Input PT: *
30*, you can find 300, 301, 302, CD: *
3000A, 3010, etc. List Stac
C:
C:To search by point type, press Search XYZ
[▲] to move to the Type field and Type:All
PT:
use [<] or [>] to change the selected
CD:
point
(All/MP/UP/CC/RE).
③If more than one point matches XYZ Data
the search criteria, the matching SS,10, ▲
points are displayed in a list. Use [^] MP,10,
SS,9,V
or [v] to highlight the point you want
MP,5
to use. Press [ENT] to select it. Del Edit Srch Inp.
Detailed data for the selected record
appears. Press [ESC] to return to
the list.
※1) If no point matches the specified criteria, an error screen appears.
130
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
XYZ Data
SS,10, ▲
①In XYZ Data menu, press [Input]. [Input] MP,10,
SS,9,V
MP,5
Del Edit Srch Inp.
②A new input point screen. N:
Displays. The PT field defaults to the Input new data E:
Z:
last recorded PT + 1, but you can +
PT: 6
change the value shown. Enter the [ENT] CD:
coordinates and the PT and CD and
then press [ENT]. When you press
[ENT] in the CD field, the point is
stored as an MP record.
N:
③After you have recording a point, E:
Z:
the next point input screen is shown
PT: 7
with the updated default You can CD:
record NE, NEZ, or Z data to the
database.
Stn Data
②Station Data list shows. Use ST,10,
[▲]/[▼] to scroll through the [▲]/[▼] ST,15,
ST,19,
records.
ST,20
Del Edit Srch
③After selecting the Data you want ST:19
to view, press [ENT] see more HI:1.600 m
BS: 20
detailed information. Press [ESC] to [ENT]
AZ:0°00′00″
return to the list. * Press [ENT] View
Del Edit Dsp
131
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
RAW Data
④Press [ENT] again display all the SS,10,
observation data from the selected [ENT] SS,10,
SS,9,V
station. ※1)
SS,5
Del Edit Srch
※1) For detailed information about each point type and format, see “11.4.1 Viewing Raw Data”.
Stn Data
ST,10,
①In Stn Data list, use [▲]/[▼] to ST,15,
ST,19,
highlight the record that you want to [▲]/[▼]
ST,20
delete. (Or in data screen which + Del Edit Srch
appears after pressing [ENT]), press [Del]
Press[ENT]:
[Del].
ST:19
HI:1.600 m
BS: 20
AZ:0°00′00″
* Press [ENT] View
Del Edit Dsp
Delete RAW Data
②To delete data, press [OK] or [OK] ST,19,
[ENT]. or * Sure?
Not to delete, press [CE]. [ENT] CE OK
③If you press [ENT],a confirming Delete Stn
dialog box appears. To delete all [OK] ! Delete all SS/SO
/CP of this STN
data of this station, press [OK] or Or
[ENT]. [ENT] * Sure?
Not to delete, press [CE]. CE OK
132
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Stn Data
ST,10,
ST,15,
ST,19,
①In Stn Data list, use [▲]/[▼] to [▲]/[▼]
ST,20
highlight the record that you want to + Del Edit Srch
edit. (Or in data screen which [Edit]
Press [ENT]:
appears after pressing [ENT].)
ST:19
Press [Edit]. HI:1.600 m
BS: 20
AZ:0°00′00″
* Press [ENT] View
Del Edit Dsp
②Program displays as the right ST: 19
graph. Input new data HI: 1.600 m
BS: 20
Input the new data manually, or +
AZ: 0°00′00″
select data from [List] or [Stac], and [ENT] * Amend & press [ENT]
then press [ENT].※1) List Stac
Edit RAW
③To rewrite the data, press [OK] or [OK] ST,19,
[ENT]. Otherwise press [CE]. or
[ENT] * Rewrite?
CE OK
Stn Data
③The system executes the ST,10,
selected operation, and returns to ST,15,
ST,19,
RAW Data screen.
ST,20
Del Edit Srch
※1) You can’t edit the current station.
●If you change the station or instrument height (HT) values, the coordinates of
observation points are not recalculated.
●If you change the BS or AZ values, raw records are not recalculated.
133
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Stn Data
ST,10,
①In Stn Data list, press [Srch]. [Srch] ST,15,
ST,19,
ST,20
Del Edit Srch
②Input the search criteria. Search Stn
Type:ST
PT:
CD:
A: List Stac
To find a point by name, enter the A:
name in the PT field and press
Search Stn
[ENT] twice.
Type:ST
PT: 9
CD:
List Stac
B:
B:You can use the wildcard. (*) in Search Stn
Type:ST
PT or CD field, for example: Input
PT: *
30*, you can find 300, 301, 302, CD: *
3000A, 3010, etc.
List Stac
134
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
PT=C1, C2, C3
The code list is a list of feature codes. You can use it to store your own codes.
1
③In PT List use [▲]/[▼] to select [▲]/[▼] 2
3
the points/ codes you want to + 4
delete, and press [Del]. [ENT] 5
Del Edit Add
1
①In the PT List use [▲]/[▼] to [▲]/[▼] 2
3
select the points/ codes you want + 4
to edit, and press [Edit]. [Edit] 5
Del Edit Add
Edit
②Input new point name/code, and Input PT/Code
PT:
press [ENT]. +
[ENT]
* Max 16 char
135
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
1
2
3
①In the point list, press [Add]. [Add] 4
5
Del Edit Add
Add
Input point
PT:
②Input the PT name, press [ENT]. name
+
* Max 16 char
[ENT]
2
③The added point appears in the 3
4
point list.※1) 5
RUIDE
Del Edit Add
※1) You can store up to 256 points.
FANGJIA
LUDING
XIEPO
①In the Code List press [Add]. [Add] GONGLU
136
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
FANGJIA
③The added code appears in the LUDING
XIEPO
code list. ※3) GONGLU
105
Del Edit Add
※1) The Rec. field is optional, when you need to save a corresponding code to every serial number,
you can input the code content in this field. For example if you input“12” in “CD” field, and input
“RUIDE” in “Rec”, it means you input RUIDE as a code, with the serial number 12.In Quick Code
function you can input serial number (CD) to call up code.
※2) To save the code same as the one in the CD field, leave the Rec field blank and press [ENT].
※3) You can store up to 256 codes.
11.5 COMMUNICATION
11.5.1 Download Data
Connect the instrument to the PC with communication cable. Install the driver of
the cable if necessary. Run the data transfer software.
a. Frist, make the communication settings in accordance with that of the total
station. Select the menu “COM” and click “Option” as follow.
137
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
138
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Then the system requests to confirm if you are ready to transfer the data.
Caution: before you click “OK” and start the transfer, make sure you have
made the following operation on the total station.
------------Comm------------------------
1. From RS232
②Choose [1] to transfer the date
2. From USB
through the RS232 cable. ※1), ※2) [1] 3. Import/Export SD
----------- Comm------------------------------
1.SendData
2.LoadData
③Select [1. SendData]. [1]
3.PT List
4.Cod List
139
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
④ SendData
Job: RUIDE
Frmt:SDR33
Data: RAW Data
Job Comm
A:Press [Job]
A:Press [Job], and then [▲]/[▼] to Job Mgr.
select the jobs from which the data * RUIDE 07-01-20
is going to be downloaded. Press @ MQ 07-01-25
RTS800 07-01-25
[ENT] to return. SURVEY 07-01-25
New Del Ctrl Info
B: B:Press [Comm]
To set the communication
<Comm>
parameter, press [Comm]. Baud:1200
To select item, press [▲]/[▼], Data L:8
To select option, press [ ]/[ ]; Parity: None
Stop: 1
Press [ENT] to return after the
setting.
⑤Set the format of the data. SendData
Press [ ]/[ ] to select the format of [ ]/[ ] Job: RUIDE
Frmt: RUIDE
the data to transfer to, and press +
Data: RAW Data
[ENT] to confirm. The data forms: [ENT]
RUIDE/ SDR33. Job Comm
Link cable
⑦Press “OK” on the communication Job: RUIDE
Send Rec:
software on your computer. [Strt]
* Open Xon/Xoff
Press [Strt] to send the data.
Abrt Strt
Link cable
⑧To stop the transfer, press the Job: RUIDE
[Stop]. Send Rec: 2
* Open Xon/Xoff
The system will return to the menu
of [Comm] after the transmission. Stop
140
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
3
※1) RTS-820R series is supportable to mini USB port and SD card.
※2) It is a must to install the cable driver if you use a multi-port cable (RS232 and mini USB
intergrated).
141
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
The system asks for a confirmation to start the transfer. Before you click OK to
transfer, you should operate the following procedure.
142
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
------------- Comm----------------------
①In the Comm menu, press [2. 1.Send Data
2.Load Data
Load Data]. [2]
3.PT List
4.Code List
A:Press [Job]
A:As shown in the right graph, Job Mgr.
press Job and then [▲]/[▼] to select * RUIDE 07-01-20
the one to load data, and press @ MQ 07-01-25
RTS800 07-01-25
[ENT] to return.. SURVEY 07-01-25
Creat DEL Ctrl Info
B:Press [Comm]
B : Set Comm parameter by
<Comm>
pressing [Comm]. To change other Baud:1200
item, press [▲]/[▼]. It should be the Length:8
same as that of the communication Parity:None
software. Stop bit:1
143
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Stop
--------------- Comm----------------------
①In the Comm menu, select [3. PT 1.Send Data
2.Load Data
List]. [PT list]
3.PT List
4.Code List
●The uploaded PT /Cod List will always replace the primary PT/Cod List in the
total station.
●You can store up to 256 codes or point names.
144
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
11.6 1 SEC-KEYS
1 Sec.Keys are the functions that when you hold down a certain key for 1
second, the setting of this key will be activated.
In the menu, press [6] to enter into the setting of [MSR], [Disp], [User], [SO] and
[Data] keys.
---------- Menu----------------------------
①In [Menu], press numeric key 1. Job 6.1 Sec.
2.Cogo 7.Adjust
[6]( or use [▼]+[ENT]) to enter into [6]
3.Set 8.Time
1 Sec. key setting. 4.Data 9.Format
5.Comm 10.Info
※1) You can also access the settings screen by holding down [MSR1] or [MSR2] for one second.
145
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
------------- 1Sec.key---------------------
①In 1 Sec. key menu, press [2] to 1.[Meas]
2.[DISP] >>Change
enter into [Disp] setting. [2]
3.[User] Display
4.[SO] Meas&SO
5.[Data]
[ ]/[ ] <DISP1> <DISP2> <DISP3>
②To move the cursor, use or HA AZ HL
VA HD V%
[ ]/[ ], [▲]/[▼]. To change the [▲]/[▼] SD VD Z
display item, press / softkey. + * Change Use /
Press [ENT] or [Save] to save the / Save
changes. +
※1) [ENT]
------- 1Sec.key------------------------
1.[Meas]
2.[Disp] >>Change
③The sceen returns to 1Sec.key
3.[Data] Display
menu. 4.[ SO ] Meas&SO
5.[Data]
※1) You can also access the Disp settings screen by holding down [DSP] for one second.
----------- 1Sec.key---------------------
①In 1 Sec. Key menu, press [3] to 1.[Meas]
2.[Disp] >>Appoint
enter into [User] setting. [3]
3.[User] Function
4.[SO] [USR]Key
5.[Data]
②There are two [USR] keys. The User Key
function that is assigned to each key 1. User1<Offset>
2. User2<Input HT>
is displayed beside the key name. [1] or [2]
Press [1] to enter into [User1]
setting. (Here take User1 as
example.) ※1)
146
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
【User1】
②Use [▲]/[▼] to select the Input HT
expecting function, and then press [▲]/[▼] BS Check
TGT
[ENT]. + Cogo→
※2) [ENT] * Offset→
If an item on the list has an arrow ↓
“→” beside, and if you select this 【Cogo (Menu】
item, the whole menu is assigned to Inverse→
AZ&Dist→
the [USR] key. To assign a specific
Area
function from the sub-menu, press LineOff.
[▲]/[▼] to highlight the function. InputXYZ
Then press [ENT].
----------- 1Sec.key---------------------
③After setting, press [ENT] to return 1.[Meas]
2.[Disp] >>Appoint
to 1Sec.Key menu. [ENT]
3.[User] Function
4.[SO] [USR] Key
5.[Data]
※1) You can also access the User settings screen by holding down [USR] for one second.
※2) The asterisk (*) indicates the function that is currently assigned to the key.
11.6.4 [SO] Key Settings
STEP OPERATION DISPLAY
----------- 1Sec.Key-----------------------
①In 1 Sec. Key menu, press [4] to 1.[Meas]
2.[Disp] >>Set
enter into [SO] setting. [4]
3.[User] Add Pt
4.[SO] SO PT
5.[Data]
Input added <S-O>
②Input added value of Stake-out value of PT
point and press [ENT]. + Add PT: 0
[ENT]
------------ 1Sec.Key-----------------------
③The display returns to 1Sec.Key 1.[Meas]
2.[Disp] >>Set
menu.
3.[User] Add Pt
4.[SO] SO PT
5.[Data]
147
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
------------ 1Sec.key-----------------------
①In 1 Sec. Key menu, press [5] to 1.[Meas]
2.[Disp] >>Set
enter into [Data] setting. [5]
3.[User] DataType
4.[SO] [DAT]Key
5.[Data]
【Data type】
②The asterisk (*) indicates the * 1.RAW Data
2.XYZ Data
currently selected view format.
3.ST→SS/SO/CP
------------- 1Sec.key-------------------------
④The display returns to 1Sec.Key 1.[Meas]
2.[Disp] >>Set
menu.
3.[User] Data Type
4.[SO] [DAT]Key
5.[Data]
* yy. mm.dd
In [Menu], select [8. Time] to enter into setting the Date & Time screen.
Date
Enter the date in Year-Month-Day format.
For example, to change the date to Jan. 2, 2007, input:
148
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
11.8 FORMAT
Format
1. Delete All Datas
2. Delete All Job
3. Initialization
Delete All Datas:Delete all data in the memory, with the jobs and job settings
unchanged.
Delete All Job:Delete all files in the memory.
Initialization:Delete all data and files, and return to initial setting.
11.9 INFORMATION
Information of instrument type, number and version are displayed.
Type:
RTS820R3 (for instance)
Number
Serial number of the plant.
Ver.
On-board software version may differs from time to time.
HVer: version of the angle measurement system
SVer: verison of the distane measurement system
149
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Check
Please refer to Chapter 3.2 “Leveling by Using Plate Vial”
Adjust
1. Adjust leveling screws, make plate bubble centered;
2. Rotate the instrument 180°; watch the offset of plate level;
3. Tweak adjustment screws (on the right of the plate vial) with the correction pin to
make plate bubble to move half of the offset back;
4. Rotate the instrument 180°, check adjustment result;
5. Repeat the steps above until the plate level is centered in all directions.
150
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
4.Adjust three adjustment screws for several times until circular bubble is
centered;
5.The force power fixing three adjustment screws must be consistent when
circular level is centered at last.
Adjust
1. If the object A does not move along with the vertical line, firstly remove the
eyepiece cover to expose the three or four reticle adjusting screws.
2. Loosen all the reticle adjusting screws uniformly with an adjusting pin. Rotate the
reticle around the sight line and align the vertical line of the reticle with pointA’.
3. Tighten the reticle adjusting screws uniformly. Repeat the inspection and
adjustment to see if the adjustment is correct.
4. Replace the eyepiece cover.
151
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Adjust
A. Electronic Adjustment Operation Steps:
STEP OPERATION DISPLAY
--------------Adjustments--------------------
1.VO Adjustments
2.Collimation
②In Adjustment press “2. [2]
3.Inst. Constant
Collimation”. 4.VADJ Set
152
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
--------------Adjustments -------------------
⑤After setting, the screen displays 1.VO Adjustments
2.Collimation
“set” ,and returns to Adjustment
3.Inst. Constant
menu automatically. 4.VADJ Set
5.VO/Axis const.
153
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Inspect the item after finishing the inspection and adjustment of items in 12.3 and
12.5.
Check
1. Power on after leveling the instrument. Collimate object A in Face I and read the
Vertical angle value L.
2. Rotate the telescope. Sight object B in Face Ⅱ and read the Vertical angle value
R.
3. If the vertical angle is 0°in zenith,i= (L+R-360°)/2
If the vertical angle is0°in horizon. i= (L+R-180°)/2or (L+R-54
0°)/2.
4. If |i| ≥10″ should set the Vertical Angle 0 Datum again.
Adjust
STEP OPERATION DISPLAY
--------------Adjustments -------------------
①In Adjustments press “1. V0 1.VO Adjustments
2.Collimation
Adjustments”. [1]
3.Inst. Constant
4.VADJ Set
Note:
1. Repeat the checking steps to measure the Index Difference (i angle). If the Index
Difference cannot meet the requirement, user should check whether the three steps
154
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
of the adjustment and the collimation are right. Then set again according to the
requirement.
2. If Index Difference still not meets the requirement after the repeated operation, the
instrument should be returned to factory for inspection and repair.
Adjust
1. Take off the protective cover between the optical plummet eyepiece and focusing
knob.
2. Fix the paper. Rotate the instrument and mark the point of the center of optical
plummet which falls on the paper at every 90. As illustrated: Point A, B, C, and D.
3. Draw lines that attach AC and BD and mark the intersection point of the two lines
as O.
4. Adjust the four adjusting screws of the optical plummet with an adjusting pin until
the center mark coincides with Point O.
5. Repeat the inspection and adjusting steps to make the instrument meets the
requirements.
6. Replace the protective cover.
155
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Check
1. Mount and level the instrument on Point A at a plain field. Use the vertical hair to
mark Point B and Point C with the distance of 50m on the same line, and set the
reflector accurately.
2. After setting temperature and air pressure, measure the horizontal distance of AB
and AC accurately.
3. Set the instrument on Point B and center it accurately, measure the Horizontal
Distance of BC accurately.
4. Then the Instrument Constant can be obtained:
K=AC-(AB+BC)
K should be near to 0, If |K|>5mm, the instrument should be strictly
inspected in the standard baseline site, and adjusted according to the inspection
value.
Adjust
If a strict inspection proves that the Instrument Constant K has changed and is
not close to 0. If the operator wants to adjust, should set Stadia Constant according
to the Constant K
●Set the orientation via the Vertical Hair to maintain Point A, B, C on the same line
precisely. There must be a fixed and clear centering mark on the ground of Point B
●Whether the prism center of Point B coincides with the Instrument Center is a
significant step to inspect the accuracy. So on Point B the tripod or compatible
tribrach should be used. It will decrease the difference.
156
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
--------------Adjustments ---------------------
①In Adjustments menu press “3. 1.VO Adjustments
2.Collimation
Inst. Constant”。 [3]
3.Inst. Constant
4.VADJ Set
Inst. Constant
②Input the constant, and press Input constant
[OK] or [Enter]. + Const: 0.0 mm
--------------Adjustments -------------------
③ Screen turns back to 1.VO Adjustments
2.Collimation
Adjustments menu.
3.Inst. Constant
4.VADJ Set
Check
1. Set the reflector 50m away from the instrument.
2. Collimate the center of the reflector prism with reticle.
3. Switch on the instrument, and enter into Distance Measurement Mode. Press
[DIST] (or [All]) to measure. Rotate the Horizontal Tangent Screw and Vertical
Tangent Screw to launch electric collimation and make the light path of EDM
unblocked. In the bright zone find the center of emitting photoelectric axis.
4. Check the center of reticle to coincide with the center of emitting photoelectric axis.
If so, the instrument is proved eligible.
Adjust
If the center of reticle deviates from the center of emitting photoelectric axis, user
should send the instrument to professional repair department.
157
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
158
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
13. SPECIFICATION
RTS-822A/825A RTS-822R3/825R3 RTS-822R5/825R5
TELESCOPE
Length 154mm
Objective Lens Diameter Telescope: 45mm Distance Meter: 50mm
Magnification 30x
Image Erect
Field of View 1°30’
Resolving Power 3”
Mini. Focus 1.0m
DISTANCE MEASUREMENT
Single Prism 2000m 5000m
Non-Prism N/A 300m 500m
Accuracy - Prims Mode ±(2mm+2ppm x D)m.s.e.
Non-Prism N/A ±(3mm+2ppm x D)m.s.e.
Measuring Time Fine: 1.2s, Normal: 0.7s Fine: 0.7s, Normal: 0.5s Fine: 0.3s, Normal: 0.2s
Meteorologic Correction Manual Input Auto Sensing
Prism Constant Manual Input
ANGLE MEASUREMENT
Method Absolute Encoding
Detecting System H: 2 sides V: 2sides
Min. Reading 1”/5”
Accuracy 2”/5
Diameter of Circle 79mm
Vertical Angle 0° Zenith: 0°/Horizontal: 0°
Unit 360°/400gon/6400mil
DISPLAY
Display Unit Graphic LCD 160x90 dots with White Backlight
No. of Unit 2 sides
Keyboard Alphanumeric Keys
TILT CORRECTION
Tilt Sensor Single Axis Dual Axis
Method Liquid Electric
Range ±3’ ±4’
Accuracy 1”
LEVEL SENSITIVITY
Plate Level 30”/2mm
159
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
GENERAL
Laser Class - EDM Class II Class IIIA
-Laser Plummet Class II
Working Temperature -20°C ~ +50°C
Battery Type Rechargeable Ni-H Battery
Battery Voltage DC 6V
Working Time 8h 16h
Precision
With reflector:
Without reflector:
EDM measuring Accuracy Standard Time per
program deviation measurement
-6
Reflectorless fine 3mm+2×10 <1.2s
-6
Reflectorless tracking 10mm+2×10 <0.8s
Beam interruptions, severe heat shimmer and moving objects blocking the
160
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Range
With reflector
Without reflector
No reflector(white No reflector
Atmospheric conditions
target)※ (grey,0.18)
3 3
Object in strong sunlight, RTS-820R : 270m RTS-820R :150m
5 5
severe heat shimmer RTS-820R : 460m RTS-820R :250m
3 3
Object in shade, or sky RTS-820R :300m RTS-820R :180m
5 5
overcast RTS-820R :500m RTS-820R :300m
※ Kodak Grey Card is used with exposure meter for reflected light
161
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
162
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
The following shows the explanation related to the key sections of the
Standard.
Laser instrument of Class 3R is applicable outdoors and in construction field
(measurement, defining lines, leveling).
a) Only those persons who are trained with related course and authenticated are
allowed to install, adjust, and operate this kind of laser instrument.
b) Stand related warning symbols in the scale of use.
163
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
c) Prevent any person to look straight at or use optical instrument to observe the
laser beam.
d) To prevent the harm caused by laser, block the laser beam at the end of the
working route. When the laser beam exceeds the limit area (harmful distance*) and
when there are motivating persons, stopping the laser beam is a must.
e) The optical path of the laser should be set higher or lower than the line of sight.
f) When the laser instrument is not in use, take care of it properly. The person who is
not authenticated is not allowed to use.
g) Prevent the laser beam from irradiating plane mirror, metal surface, window, etc.,
especially beware of the surface of plane mirror and concave mirror.
* Harmful distance means the maximum distance between the start point and
the point which the laser is weakened to a degree that doesn’t harm people.
The internal EDM instrument equipped with a Class 3R/III a Laser has a harmful
distance of 1000m (3300ft). Beyond this distance, the laser intensity is weakened to
Class I (Looking straight at the laser beam causes no harm to the eyes.)
164
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
16. ACCESSORIES
item quantity
carrying case 1
battery 2
charger 1
plummet 1
correcting pin 2
fur brush 1
screw driver 1
hexagon wrench 2
cloth 1
dryer 1
operating manual 1
warrenty certificate 1
rain cover 1
software CD 1
165
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
166
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
2. COORDINATE DATA
The format of uploaded/downloaded coordinate data is determined by user’s
setting. For example: the coordinate format is set as:
PointID, E,N,Z,Code
101,994.890,1000.964,100.113,RUIDE
102,993.936,1007.799,100.800,STN
103,998.515,1009.639,100.426,STN
104,1002.068,1002.568,100.342,STN
1001,1004.729,997.649,100.1153,PT
1002,1003.702,990.838,100.799,PT
1003,7911.990,990.358,100.403,PT
1004,997.311,998.236,100.354,PT
3. CODE LIST
The code list which is put in the code store, should be guaranteed that every line
has one code which includes serial number and code, and every line is ended by
carriage returns. The format of code list is:
Serial number (quick code number), code
When there is no definition of code, the code is default as the content of serial
number. In quick code function, one can transfer code by entering serial number.
For example:
1,VEG
2,BDY
3,CL
4,ROAD
167
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
5,ROAD
6,PATH
7,DRAIN
8,CONTROL
9,DRAIN
10,UTILITY
11,UTILITY
4. HORIZONTAL LINE
The horizontal line is transmitted from computer to instrument through line
element, including initial definition. It should be included in initial definition the number
of the start stake and coordinate of this point. The line elements include point,
straight, arc, and transition curve.
Each recorded format is:
(KEYWORD) nnn, nnn [, nnn]
Here:
START POINT stake number, E, N
STRAIGHT azimuth, distance
ARC radius, arc length
SPIRAL radius, length
PT E,N[,A1,A2]
(A1, A2: LENGTH)
For example1:
START 1000.000, 1050.000, 1100.000
STRAIGHT 25.0000, 48.420
SPIRAL 20.000, 20.000
ARC 20.000, 23.141
SPIRAL 20.000, 20.000
STRAIGHT 148.300, 54.679
Example 2:
START 1000.000, 1050.000, 1100.000
PT 1750.000, 1300.000, 100.000, 80.800
PT 1400.000, 1750.000, 200.000
PT 1800.000, 2000.000
168
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
5. VERTICAL CURVE
Input vertical curve data from computer through typical point and stake number,
the vertical curve data should include the height, curve length, and the curve length
of start point and terminal point is zero.
Data format is:
Stake number, height, length
For example:
1000.000, 50.000, 0.000
1300.000, 70.000, 300.000
1800.000, 70.000, 300.000
2300.000, 90.000, 0.000
169
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
170
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
Example:
To enter the following data select DEF AL of ROADS in PROG menu:
Stake number 0
N 1100.000
E 1050.000
Press [ENT] and then press [F4] (PT), Enter the following data:
N 1300.000
E 1750.000
R 100.000
A1 80.000
A2 80.000
N 2000.000
E 1800.000
R 0.000
A1 0.000
A2 0.000
2
A1.2
L 12. = L 12. : Length of clothoid
R
A1.2 : Parameter of clothoid
R : Radius
171
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
2 2 2 2
A1 80 A2 80
L1 = R = 100 =64 m L2 = R = 100 =64 m
= L2
2A
2
180
= 264
1
= 0.32 rad
2
deg 0.32
=18°20′06″
80
= -
1 2
N A 2 (1
2 4 6
....)
10 216 9360
E A 2 (
3 5 7
....)
3 42 1320 7560
2 4 6
(0.32) (0.32) (0.32)
N 80 2 0.32 (1 ....)
10 216 9360
0.01024 0.01048576 0.00107341824
64(1 )
10 216 9360
64(1 0.01024 0.00004855 0.00000011)
64 * 0.98981
63.348
Similarly, the value of E is:
3 5 7
0.32 (0.32) (0.32) (0.32)
E 80 2 0.32 ( ....)
3 42 1320 7560
6.777
This example is symmetry spiral transition. N1=N2,E1=E2
172
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
R E R(1 cos )
1.700
Symmetry spiral transition R1 R2
N m N R s i n =63.348-100sin18°20′06″=31.891
LA
D1 R tan( 2 ) R2 cos ec ( LA) R1 cot( LA) N m1
1 1
LA 111°55′47″, c o sec , cot
sin tan
D1 D2
173
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
=R(111°55′47″-2 * 18°20′06″)
=100( 75°15′35″
)
180
=131.353 m
N BC N IP2 TL cos 2
E BC E IP2 TL sin 2
N EC N IP2 TL cos 3
174
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
here:
straight line
175
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80
straight line
176
Тахеометры http://taheometr-geo.ru +7 (499) 643-33-80