Rwprorox SL 960

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Technical Insulation

ProRox WM 988 Heavy duty wired mat

Dimensions

Standard Width: 600 mm Standard Width: 1200 mm

Thickness (mm) Length (mm) Thickness (mm) Length (mm)


40 6000 40 6000
50 5000 50 5000
60 4000 60 4000
75 4000 75 4000
80 1500 80 1500

Applications Installation guidelines


ProRox WM 988 is a lightly bonded heavy Assembly Support construction
duty stone wool mat stitched on galvanised Cut the wired mat to length, so that the mat Given the limited pressure resistance of wired
wired mesh with galvanised wire. The wired fits the pipe with slight pre-stressing. The mats, in most cases a support is required for
mat is especially suitable for industrial closing joints must be staggered at an angle the board cladding. As a guideline, assume
applications such as high-pressure steam of at least 30 degrees to each other. The that a support is required every 3 to 4 metres.
pipes, reactors, furnaces, etc. where high closing joints of the mats (lengthwise and
extreme demands are made on the circular joints) must be wired together using Finishing
temperature resistance of the insulation. e.g. steel wire (min. 0.5 mm) or secured with The insulation should be finished with a metal
Stainless steel mesh, stainless steel binding mat hooks. Stainless steel pipes and pipes (e.g. aluminium) cladding. Where necessary,
wire and/or aluminium foil facing are with a temperature of >400°C should expansion joints are provided to cater for
available upon request. preferably be insulated with ProRox WM 970, expansion of the pipes. Both the lengthwise
in which both the mesh and the stitching wire and circular joints are fastened with sheet-
Compliance is in stainless steel. If the mats are assembled metal screws: hard aluminium or stainless
ProRox WM 988 Wired Mats fully comply in multiple layers, both the lengthwise and steel 1/2”, 8/metre. Close the expansion
with the requirements as set by circular joints must be staggered (‘masonry joints with a steel tensioning wire.
internationally recognized standards like bond’). Connections to mountings, head and end
CINI 2.2.02, ASTM C592 Type I, II, III and IS caps, etc. should be made watertight using a
8183. suitable sealant.

ProRox Product Catalogue


22
Technical Insulation

ProRox WM 988 Heavy duty wired mat

Note Advantages
All steel components exposed to a Suitable for heavy duty applications which are exposed to high temperatures and
corrosive environment should be high mechanical loads
cleaned, de-greased and coated with Resistant to high temperatures
a protective finish. Flexible application
Available in a wide range of thicknesses
Suitable for use over stainless steel

Product properties1

Properties Performance Standard


Mean Temp (°C) 50 100 150 200 250 300
Thermal Conductivity2 λ (W/mK) 0.038 0.043 0.048 0.055 0.064 0.076 ASTM C177
λ (W/mK) 0.039 0.047 0.055 0.064 0.075 0.086 IS 3346

Nominal Density 150 kg/m³ ASTM C167/ IS 3144


No visible deterioration of the fibrous structure.
Heat Resistance IS 3144
No evidence of self heating. No fusion of fibers at 750°C
Maximum Service
750°C ASTM C411/C447
Temperature
Linear Shrinkage Less than 2% (at max service temperature) ASTM C356
Incombustibility <5 wt% IS 3144
EuroClass A1
EN 13501-1
Reaction to Fire Surface burning characteristics;
ASTM E84
Flame spread = passed, Smoke development = passed
pH 7-10 IS 3144
Less than 10 ppm
Water Leachable ASTM C871/ IS 3144
Conforms to the stainless steel corrosion specification
Chloride Content ASTM C692/C871
as per ASTM C795
Sulphur Content < 0.3 vol% IS 3144
Water Absorption Less than 1 kg/m² EN 1609
ASTM C1104/C1104M
Moisture Absorption Less than 1% weight
IS 3144
> 250μm < 8 wt%
Shot Content IS 3144
> 500μm <3 wt%

Note: 1. All information and data for technical parameters are based on laboratory testing.
2. Nominal values.

ProRox Product Catalogue