Sys/Ftbg-100 Series: With Atex Enclosures

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

GAS TURBINE AND

TRANSMITTER SYSTEMS
WITH ATEX ENCLOSURES

SYS/FTBG-100 Series

Standard

U Outstanding Accuracy
U Hybrid Ceramic Bearings
for Superior Life
UD  C or AC (Optional) Power
U Pulse and Analog Output
U Optional Hi and Lo Alarms
SYS/FTBG-101/FLSC-C3,
UF  actory Configured shown smaller than
U Windows ® Configuration actual size.
Software (Included)

OMEGA’s high accuracy Gas F


Turbine Series measures the
volumetric flow of gas through a
pipeline. Gas flowing through the
meter turns the turbine rotor at an
angular velocity which is
proportional to the velocity of the
gas being measured. As the
turbine rotor turns, the rotor blades
pass a non‑intrusive pickup coil that
generates an electrical signal,
referred to as a pulse. Each pulse
represents a specific volume of gas
(i.e. ACF/AM3). The totalization of these
pulses results in the total volumetric flow. The total
volume can be converted to mass flow total (SCF or
NM3) using reference conditions and base density, or
by applying various correction techniques. Standard An OMEGA® gas turbine flowmeter should be chosen
calibrations for these gas turbine systems are per- so that it is operated within its most accurate range.
formed at a reference density of 0.1 lb/Ft3. A 10-point The capacity of a turbine flowmeter is based on the
calibration certificate (traceable to NIST or other actual volumetric flow rate and is expressed as actual
recognized national laboratory) is supplied with each cubic feet (ACF) or actual cubic meters (AM3). The
meter. Standard calibration includes a calculated lower limit of operation is a function of the gas density
K-factor for gas that is derived from a 10-point and velocity.
NIST calibration for water. Calibrations at customer’s
actual operating densities can be performed with
special order.
Specifications (Turbine)
OMEGA’s gas turbine flowmeters offer high accuracy Over-range: 150% of maximum flow (intermittently)
measurement of gases for a wide variety of applications, Turn Down Range: Dependent on gas density at user’s
including fiscal measurement, plant cost allocation, operating conditions
energy consumption/conservation, etc. These gas Linearity: ±1% of reading typical
turbine systems are suitable for all non‑corrosive Repeatability: ±0.25% over tabulated repeatable range
gases such as natural gas, air and nitrogen. Special Available Temperature Range: -157 to 149°C
versions of this series are available for use on (-250 to 300°F) continuous
corrosive gases, such as “off-gas” and feature End Fittings (Standard): NPT
NACE- MR175 trim and self-lubricated ceramic ball Bearing Styles: Self-lubricating, ceramic hybrid ball bearings
bearings. Contact OMEGA for further details. Materials: 316/316L dual rated stainless steel with 17.4 pH rotor
F-1
FLSC-C3, shown
smaller than actual size.

Specifications
(Signal Conditioner)
Input Signal Type: MCP pickup
Input Frequency Range: 0.2 Hz to 4 KHz
Signal Level: 10 mV rms to 30 Vdc
Power Supply: 13 to 30 Vdc standard,
100 to 240 Vac (-AC) (optional),
reverse polarity protection
Analog Output: 4 to 20 mA, 1 to 5V,
24 mA overflow condition
(dip switch selectable)
Load Resistance:
Maximum 650 Ω @ 24 Vdc
Accuracy: ±0.02% of full scale
Temperature Drift: 40 ppm/°C
Pulse Output: 0 to 5V
Recommended Minimum Load
Resistance: 50 KΩ Linearization: Up to 20 points
Pulse Scaling: Divide by 1,10,100 per flow unit of measure Operating Temperature: -40 to 85°C (-40 to 185°F)
Hi/Lo Alarm (Optional): Relay (2A, 30 Vdc), Humidity: 0 to 90% non-condensing
0 to 5V, open collector (0.5A, 30V) Enclosure: Extruded aluminum explosion-proof ATEX
Communications: RS232 port for configuration Port: 3⁄4 -14 NPT
and diagnostics Regulatory: CE compliant

To Order Visit omega.com/sys_ftbg-100 for Pricing and Details


Nat Gas 2 to 3 psi Air 35 to 40 psi
@ 0.05lb/FT3 @ 0.25lb/FT3
Pressure Pressure
Meter Blade Range Drop Range Drop Maximum
Model Number Description Size NPT Angle ACFM (PSID) ACFM (PSID) Pressure
SYS/FTBG-101/FLSC-C3 Gas turbine ¹⁄₄ ¹⁄₂ 30° 0.3 to 1.6 0.1 0.13 to 1.6 0.5
SYS/FTBG-102/FLSC-C3 Gas turbine ¹⁄₄ ¹⁄₂ 15° 0.65 to 3.5 0.02 0.35 to 3.5 0.1
6000 psi
SYS/FTBG-103/FLSC-C3 Gas turbine ³⁄₈ ¹⁄₂ 30° 0.6 to 2.3 0.1 0.27 to 2.3 0.5
SYS/FTBG-104/FLSC-C3 Gas turbine ³⁄₈ ¹⁄₂ 15° 1.3 to 5 0.02 0.6 to 5 0.1
SYS/FTBG-105/FLSC-C3 Gas turbine ⁵⁄₈ ³⁄₄ 30° 1 to 4.4 0.1 0.45 to 4.4 0.5
SYS/FTBG-106/FLSC-C3 Gas turbine ⁵⁄₈ ³⁄₄ 15° 2.17 to 9.5 0.025 1 to 10 0.125
4400 psi
SYS/FTBG-107/FLSC-C3 Gas turbine ³⁄₄ ³⁄₄ 30° 1.2 to 9.2 0.1 0.54 to 9.2 0.5
SYS/FTBG-108/FLSC-C3 Gas turbine ³⁄₄ ³⁄₄ 15° 2.6 to 20 0.02 1.2 to 20 0.1
SYS/FTBG-109/FLSC-C3 Gas turbine 1 1 30° 1.6 to 20 0.2 0.72 to 20 1
3850 psi
SYS/FTBG-110/FLSC-C3 Gas turbine 1 1 15° 3.5 to 43 0.04 1.6 to 43 0.2
SYS/FTBG-111/FLSC-C3 Gas turbine 1¹⁄₂ 1¹⁄₂ 30° 3.5 to 55.5 0.15 1.6 to 55.6 0.75
3500 psi
SYS/FTBG-112/FLSC-C3 Gas turbine 1¹⁄₂ 1¹⁄₂ 15° 7.6 to 120 0.035 3.5 to 120 0.175
SYS/FTBG-113/FLSC-C3 Gas turbine 2 2 30° 7 to 93 0.3 3.1 to 93 1.5
3000 psi
SYS/FTBG-114/FLSC-C3 Gas turbine 2 2 15° 15 to 200 0.0625 7 to 200 0.3125
SYS/FTBG-115/FLSC-C3 Gas turbine 3 3 30° 15 to 363 0.4 6.7 to 363 2
1500 psi
SYS/FTBG-116/FLSC-C3 Gas turbine 3 3 15° 35 to 600 0.1 15 to 600 0.5
Systems come complete with turbine, signal conditioner and operator’s manual.
For units with 100 to 240 Vac power add “-VAC” to model number, for additional cost, not available with alarm option.
For units with optional high/low alarm relay add “-AL” to the model number, for additional cost.
Signal Conditioners/Accessories
Model Number Range Description
FLSC-C3 4 to 20 mA CE Replacement signal conditioner† only for gas turbine system
FLSC-C3-AL 4 to 20 mA and alarm CE Replacement signal conditioner† with alarm only for gas turbine system
OM-CONV-USB — USB to RS232 converter
FLSC-C-CABLE — 9-pin D connector to transmitter Molex
† Replacement signal conditioners require the purchase of FLSC-C-CABLE to enable them to be programmed in the field. Required software
available free at omega.com/ftp.
Ordering Example: SYS/FTBG-107/FLSC-C3, 3⁄4" gas turbine with 4 to 20 mA signal conditioner.