Sirena PA200
Sirena PA200
Sirena PA200
1. Choose the mounting location for the siren{he wall must be even and free of hole and
excessive protrusions.
2. Mark and drill 5 holes with help of attach drill pattern plate (4 holes for the housing base and
for the hanging hole).
3. Open the siren housing (1 screw on the front),and remove the metal cover (2 screws)
4. UnPlug the removable terminal, mount the siren housing on the wall. Connect the wires to ihe
terminals.
' keep attent¡on to the polorit\ of the battery; a reterse poluif can cause
of the drtuer circuit.
--
ut door- Strobe EÉ Lll
I
- ,orao nr, EÉ I
-- ñO *mñ/aLffi
ram tD-
-
r-
-
O
-
sPr
-
Irr
Lr-----11
I
li.::;;;H
Terminal 1-Marked "FL-"trigger for the flashlight only, it is connected to the negative output of the
alarm system, Active while the input is low.
Terminal 2- Marked "Go-" trigger for the siren and the flashlight, active while the input is negative.
Terminal 3-Marked "GO+" trigger for the siren and flashlight, active while the input is positive.
Terminal 4-Marked the "GND" connect to the ground of the control unit.
Terminal S-Marked"+14V" connect to a positive voltage output of the 13.6-14.2VDC source (usually
from the alarm control unit).
Terminal 6&7-Marked 'TMP" if a tamper function is required. Connect these terminals to a 24-hour
normally closed alarm zone in the control unit, if the front cover of the siren is opened or siren box is
taken from the wall, an immediate alarm signal will be sent to the control unit.
Siren Specifications
'120db
SPL
\larm [email protected]
Trigger High=Min.9VDC
3 minutes
C
o
o
C
Outdoor Back-up Batteru Siren
Manual lnstallation
The outdoor siren is a new generation of professional high power acoustic siren with battery back-up
and flashlight, which includes all pedormance and reliability for security alarm system.
Features:
OOutdoor battery back-up siren with lamp light or strobe light.
ODouble housing:External-3mm plastic ABS with UV perention, internal 0.8mm metal case.
lContinuous frequency modulated sound.
aTamper protection in 3 ways -screw or cover opening or taking off housing from the wall.
aPositive and negative alarm trigger input.
I Negative trigger input to active the light only.
Applying alarm negative trigger to "FL-" terminal to trigger the flashlight. Flashlight duration is not
limited and the t¡me of flashlight is up to control panel.
Tamper:
N/O and N/C tamper switch is equiped. The default is N/C. While the housing is closed with the
screw, the tamper terminals are shorted (0 ohm). User can change N/C to N/O if necessary.
Power Failure:
When power failure, the siren and flashlight are triggered until power supply is restored or battery
voltate is less than 8VDC.
Batterv Protection:
The siren is supplied with protection against totally battery discharge by cutting off the siren, when
voltage level falls down to less then 8VDC.