Operating The Thermoguard Up V Microprocessor PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

OPERATING THE CHANGING THE SETPOINT MANUAL DEFROST CYCLE

THERMOGUARD PP-V 1. Turn unit On/Off Switch "on". 1. Turn unit On/Off switch "on".

MICROPROCESSOR 2. Press Up and Down Arrow keys to chose 2. Press the Select key to display [dEF].
the new setpoint.
3. Press the Enter key. The display will
3. Press the Enter key. The display will briefly show [LOAD], and then the unit will
briefly show [LOAD], and then the new enter a defrost cycle. The defrost cycle will
THERMOGUARD PP V setpoint will reappear. terminate automatically.
TEMPERATURE

CYCLE
COOL
SENTRY
HEAT
! ALARM
DEFROST
MODULATION
SELECTING CYCLE SENTRY
HIGH SPEED
IN-RANGE OR CONTINUOUS MODE VIEWING PROMPT & DISPLAY
SETPOINT
1. Turn unit On/Off switch "on". SCREENS
1. Turn the unit "on".
2. Press the Select key to display [CYCLS]
and [YES] or [NO]. 2. Press the Select key to view the prompt
and display screens as follows:
3. Press the Up or Down Arrow key to
select the desired mode. [YES] = Cycle [dEF] Defrost Prompt *
HOURS OIL PRESS WATER TEMP AMPS Sentry mode, [NO] = Continuous mode. [CYCLS] Cycle Sentry Prompt
[DIS.A] Discharge Air Temperature
4. Press the Enter key. The display will [TPDF] Temperature Differential
briefly show [LOAD], and then the new [COIL] Evaporator Coil Temperature
SELECT SETPOINT ENTER CODE CLEAR

ALARM
mode will reappear. [AMB.T] Ambient Air Temperature
[SPR.1] Spare Sensor 1
[SPR.2] Spare Sensor 2
STARTING THE ENGINE [BATV] Battery Voltage
ON
1. Turn the unit On/Off switch "on". If no [RPM] Engine RPM
other key is pressed, the engine will [DEFI] Defrost Interval In Range
OFF
automatically preheat and start in about 10 [DEFN] Defrost Interval Not In Range
CAUTION: WHEN
SWITCH IS ON, UNIT
seconds. [DDUR] Defrost Duration
MAY START ANYTIME
[MVST] Mod Valve Close on Start*
CAUTION: The engine starts
automatically in both Cycle Sentry and * = May not always appear
Continuous mode any time the On/Off
switch is "on".
TK 50114 25 September 1997
ALARM CODES ALARM CODES
VIEWING & CLEARING ALARM
00 No Fault 48 Check Belts/Clutch
CODES
01 Micro Power Up (Data Log Only) 50 Reset Clock
1. If the Alarm Icon is "on", alarm conditions 02 Evaporator Coil Sensor 52 Heat Circuit
have been detected. 03 Return Air Sensor 54 Test Mode Timeout
04 Discharge Air Sensor 55 Check Engine Speeds
2. Press the Code key to display the alarm 05 Ambient Air Sensor 61 Battery Check
code. Press the Code key again to display 06 Engine Water Temp Sensor 62 Ammeter Out of Calibration Range
any additional alarm codes. Always record 07 Engine RPM Sensor 63 Engine Stopped - Reason Unknown
any alarm codes shown. 09 High Evaporator Temp 64 Pretrip Reminder
10 High Discharge Pressure 66 Low Engine Oil Level
11 Unit Controlling on Discharge Air Sensor 70 Hourmeters Exceed 99999
4. After the alarm condition has been
12 Sensor Shutdown 71 Hourmeter 4 Exceeds set limit
corrected, press the Code key to display the 13 Check Sensor Calibration 72 Hourmeter 5 Exceeds set limit
alarm code again. When the alarm code is 15 Glow Plug Check 73 Hourmeter 6 Exceeds set limit
shown in the display, press the Clear key to 17 Engine Failed to Crank 74 Micro Reverted to Default Settings
clear the alarm. 18 High Engine Water Temp 75 Internal Fault Code, Dealer Resettable
19 Low Engine Oil Pressure 76 Internal Fault Code, Dealer Resettable
20 Engine Failed to Start 77 Internal Fault Code, Dealer Resettable
RUNNING A PRETRIP TEST 21 Cooling Cycle Check 78 Internal Fault Code, Dealer Resettable
22 Heating Cycle Check 79 Data Log Overflow
1. Turn the unit On/Off Switch "on". 23 Cooling Cycle Fault 84 Restart Null
24 Heating Cycle Fault
2. Clear any alarm codes that may exist. 25 Alternator Check
26 Check Refrigeration Capacity OPTIONAL SLEEP MODE
3. Before the engine starts, press and hold 28 Pretrip Abort Place the optional On/Off/Sleep switch in
the Thermo King Logo key for at least 3 29 Defrost Damper Circuit the "Sleep" position. The display will show
seconds. The Pretrip prompt screen [PrE 30 Damper Stuck Closed [SLEEP MODE]. The unit will start and stop
TRIP] will appear. 31 Oil Pressure Switch
to keep the engine warm and battery
32 Refrigeration Capacity Low
33 Check Engine RPM charged but will not control to setpoint.
4. Press the Enter key to start a Pretrip test. 34 Modulation Circuit
The display will briefly show [LOAD] and ON
35 Run Relay Circuit
then the test will begin. OFF
36 Electric Motor Failed to Run
37 Check Engine Water Level SLEEP
ZZZ CAUTION: WHEN
5. The test is fully automatic. When it is 38 Electric Phase Reversed SWITCH IS ON, UNIT
MAY START ANYTIME
complete [PASS], [CHEC] or [FAIL] will 40 High Speed Circuit
appear on the display. 41 Engine Water Temperature Check
42 Unit Forced to Low Speed
43 Unit Forced to Low Speed Modulation ADDITIONAL INFORMATION
6. If [CHEC] or [FAIL] appears, display and For additional information consult the
44 Fuel System Check
correct any alarm codes and repeat the test. 45 Hot Gas Circuit Thermo King Operating, Maintenance, Parts
46 Air Flow Check and Diagnostic Manuals for your unit.