AC DC SWITCHING POWER MODULE LP100DM SERIES

Patents Held.
Features
Green Power
● Easy Din Rail mounting
● No-load Consumption is lower than 0.3W
● Compliant with High Efficiency 80Plus Criteria
● Complies with 2010 Energy Conservation Erp Regulation
● “ Output Voltage Monitor ” Display
● Convection cooled
● Wide input range
● 100% burn-in test
● 1 years warranty
● Output modification range 3~200VDC (specials only)
DIMENSIONS:100(H)*83(D)*49(W)mm WEIGHTS: 365g

General specifications
INPUT OUTPUT
Input range 90~132/180~264VAC(Selectable) Hold-up time 13ms
220~380VDC Short protection Autorecovery
Input frequency 47~63Hz Over load protection Automatic power limited
Inrush current (25°C) 20A/110VAC
40A/220VAC

Detail specifications
100 Watts
O/P Volt Load(Current) Ripple
1 Line Load Efficiency
MODEL Adj. % & O.V.P
Min. Rated Max. REG. REG.
Noise 4 2 3 5
LP1100D-12M V : +12V ±10% 0A 8.3A 8.3A 120mV ±1% ±1% 85% Ref. 17.1 ~ 18.9V

LP1100D-24M V : +24V ±10% 0A 4.2A 4.2A 240mV ±1% ±1% 86% Ref. 31.4 ~ 34.7V
● LP1100D-48M V : +48V ±10% 0A 2.1A 2.1A 480mV ±1% ±1% 87% Ref. 64.6 ~ 71.4V
Please choose functions, and fill In the blanks with appropriate suffix.
Order Model:LP1100D-XXM□□ □
Optional Function:
Terminal Block: " " : PCB Barrier Terminal Block◄ Motion: " " : No Monitor◄ Type: " " : No Display Function◄
"E" : Mini Terminal Block◄ "D" : Monitor Display◄ "A" : Output Voltage Display◄

EMC Standards Safety


Safety Standards Environments
EN 55022 CLASS A Standards Operating Temperature
o
-15 ~ 50 C, Ambient
EN 61000-3-3, UL 508 Certificate Operating Humidity 5 ~ 95% RH, No Condensing
o
EN 55024 (IEC 61000-4-2, Storage Temperature -20 ~ 85 C, Ambient
IEC 61000-4-3,iEC 61000-4-4, Vibration 2G, 10~500Hz, 3 axes
IEC 61000-4-5IEC 61000-4-6, CE Marking
IEC 61000-4-8IEC 61000-4-11)
NOTE
1. Each output can provide up to maximum load, but total load can not exceed rated output power.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 220VAC input.
4. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a
0.1uf & 47uf parallel capacitor.
5. Efficiency is measured at rated load and 220VAC input.
6. Hold-up time is measured at rated load and 220VAC input.
7. With ● do not have safety approval and are therefore not sold in UK.
8. Reign Power reserve the right to change specifications at any time without notice.