TEL-TRU® MANUFACTURING COMPANY

BIMETAL THERMOMETERS

S inc e
World-Class Thermometers 1 9 1 6 www.teltru.com
Tel-Tru® Manufacturing Company
World-Class Thermometers
We manufacture thermometers — but we sell service, reliability, product
quality and performance, and our experience working with customers to solve
temperature measurement and monitoring application problems.

Since my grandfather Harry Germanow started making household products in


1916 to today’s temperature and pressure instruments, serving industrial,
commercial, and OEM markets, our tradition has been to meet or exceed
customer expectations.

Our goal is total customer satisfaction through World-Class manufacturing,


service and support.

Tel-Tru’s World-Class philosophy encompasses a customer-centric staff and


culture supported by state-of-the-art equipment and manufacturing
processes.

In our Rochester, NY factory, we continually make investments to expand and


improve our capabilities and our capacity to produce bimetal thermometers
that are the world-standard for quality workmanship and accuracy.

This product brochure provides you with a view of Tel-Tru quality as well as
all the information you need to select the bimetal thermometer most
appropriate for your application.

We look forward to providing you with a World-Class experience — the


tradition continues!

Andy Germanow
President
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

Table of Contents
QUALITY AND PERFORMANCE FEATURES
Bimetal Thermometers Cross Section of Quality. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
SELECTING YOUR THERMOMETER
Considerations When Selecting Bimetal Thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
Safety and Application Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
Recommendations for Checking the Calibration of Bimetal Thermometer. . . . . . . . . . . . . . . . . page 5
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
How to Order. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
Standard Features and Available Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
PRODUCTS
3", 4" and 5" Adjustable Angle Industrial Thermometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
3", 4" and 5" Back Connected Industrial Thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
3", 4" and 5" Bottom Connected Industrial Thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
13/4" and 2" Back Connected Industrial Thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
13/4", 2" and 3" Laboratory Testing and General Purpose Thermometers. . . . . . . . . . . . . . . . . . . page 16
1" and 13/8" Testing and Spot Checking Thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18
OPTIONS AND ACCESSORIES
Connections, Fittings, Lenses, Dials, Tagging and Mounting Flanges. . . . . . . . . . . . . . . . . . . . . . page 20
Thermowell Adapter kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 20
THERMOWELLS
Threaded, Flanged, Welded, Sanitary and Van Stone. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21
SPECIAL CONFIGURATION AND APPLICATION THERMOMETERS
OEM Thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22
Heavy Duty Marine Thermometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22
Silicone Filled Thermometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 23
Thermometers with Heavy Duty Pointed Stem and Detachable Handle . . . . . . . . . . . . . . . . . . . page 23
Sanitary Bimetal Thermometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 23
Glow Dial and Reflective Thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 24
Minimum and Maximum Thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 24
Food Service Thermometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 25
Check-Set™ Thermometer Calibrators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 25
TEL-TRU BIMETAL THERMOMETERS ARE MANUFACTURED IN THE USA.
Page 1
Tel-Tru® Manufacturing Company
World-Class Thermometers
We manufacture thermometers - but we sell service, reliability, product quality and performance.

➤ QUALITY AND PERFORMANCE FEATURES:


★ CASE AND BEZEL ★ LENS
• 304 stainless steel standard • Extra heavy duty instrument glass standard
• 316 stainless steel optional • Shatterproof glass, tempered glass, and plastics
• All external parts corrosion resistant to most optional
chemicals
• Parts designed for maximum strength to meet
requirements of heavy duty industrial applications
• Manufactured with precision tooling on modern ★ POINTER
OSHA approved stamping equipment
• Black painted aluminum
• Statistical Process Control QA methods used to • Balanced and precisely assembled to bimetal coil stem
assure component quality and process consistency
• Polished finish identifies Tel-Tru quality • Direct transfer of coil movement to temperature
displayed on dial
• Cases may be silicone filled for additional
dampening of extreme vibration, or to assure
consistent performance in low process
temperature/high environmental humidity
applications

★ DATE STAMPING
• Available for QA tracking of industrial
thermometers

★ EXTERNAL RESET
• Calibration adjustment using an Allen wrench
discourages inadvertent tampering
★ HERMETIC SEAL
• Stainless steel pinion is sealed with a silicone
“O” ring to maintain integrity of hermetic seal
• Case/Bezel assembly is a precision interference fit • Pinion works with gear teeth cut and formed in dial
• Silicone gasket provides dustproof and leakproof seal • Models without reset are available
• Welded construction-Unique 360º TIG
weld joins case, stem and threaded connection ★ DIAL
• Testing conforms with ASME B40.3 procedures • True anti-parallax dial on 3", 4"' 5" models
• Graduations on dial ring are on the same plane as
the pointer tip minimizing reading error
• Concave design of dial ring enhances readability
★ THREADED CONNECTION • White appearing .032" anodized aluminum
• 304 stainless steel standard • Graduations for each temperature range are
• 316 stainless steel optional calculated to match deflection data of bimetallic
material
• Precision manufactured on Tel-Tru CNC machines • Large easy to read black numerals and
• Statistical Process Control QA methods used to graduations are printed on precision pad
assure component quality and process consistency
printing equipment in our factory

Page 2
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

★ BIMETAL COIL
• Super sensitive bimetallic helix coil
• Fabricated to tight tolerances
• Heat treated for stress relief
• Silicone coated to minimize pointer vibration
and maximize heat transfer and response time
• Angular deflection of each coil is tested for perfect
match with dial graduation layouts in precision MADE IN USA
calibration baths designed and built by Tel-Tru
with accuracy to ±1/10°F

★ ACCURACY
• Per ASME B40.3 Grade A ±1% full span is
guaranteed
• Calibration is to standards traceable to National
Institute of Standards and Testing (NIST)
• Tel-Tru methods:
* Most careful and precise in the industry
* Produces typical accuracy better than ASME B40.3
Grade AA (1%-1/2%-1%) full span

★ BIMETAL BUSHING ★ QUALITY SYSTEM


• Pressed into groove on stem • ISO 9000 comparable
• Centers coil in stem • Assures that all materials, methods and processes
• 302 stainless steel stem wire goes through meet Tel-Tru’s highest standards for form, fit,
center of bushing connecting bimetal element and function
to pointer, minimizes coil touching tube wall • Statistical Process Control QA methods used
• Centering bearings are used at regular intervals to assure component quality and process
on long stem thermometers consistency
• Calibration lab for NIST traceable verification of all
standard thermometers and measuring instruments
★ TEMPERATURE RANGES used in manufacturing process
• 20 Standard Fahrenheit ranges from -100° to 1000°
• 20 Standard Celsius ranges from -75° to 550°
• 13 Standard Dual scale ranges
• Availability of over 120 ranges developed, may vary
by dial size

★ OVER TEMPERATURE LIMITS


• Up to 250°F 100% ★ IMMERSION:
• 250° F to 550°F
50% • Groove around stem shows minimum immersion
• 550° F to 1000°F
800°F for continuous use, point on each thermometer
intermittent use over 800°F • For most accurate reading sensitive portion of stem
must be completely immersed

★ STEM
• 304 Stainless steel tubing is welded/drawn
and fabricated to exacting tolerances
• 316 stainless steel optional
• Standard stem diameter is .250" (6.35mm) –
options include .375" (9.52mm), .236" (6mm)
and .315" (8mm)
• Stem lengths available from 21/2" to 120"
• Tip is welded and finished for hermetic seal and
unique look

Page 3
Selecting Your Thermometer

➤ CONSIDERATIONS WHEN SELECTING BIMETAL THERMOMETERS:


MATERIALS TEMPERATURE RANGE
• Application? Continuous process flow, static tank, • Operating temperature of process? High and low
or laboratory testing etc. • Overall temperature range required? High and low
• Environmental conditions? Ambient temperature, humidity, • Over-Range possibilities? Minimum and maximum
or corrosive atmosphere (salt spray etc.) • Accuracy required?
• Process conditions? Pressure, temperature, media viscosity, • External reset required?
rate of flow, and possible vibration
• Wetted material of thermometer compatible with • Scale - °F, °C or dual?
measured medium? • Bimetal thermometers should not be used continuously
over 800°F (450°C)
• Window material?
MODEL TYPE OPTIONS AND ACCESSORIES
• Dial size? • Thermowell?
• Location of fitting connection for maximum readability • Silicone filling?
when thermometer is installed in system– Back, adjustable • Minimum and/or maximum indicating pointers?
angle, bottom, top, right side or left side connection location? • Custom or special dial marking or colors?
• Fitting thread size and type? • Sliding compression fittings– male or female?
STEM • Thread size adapters?
• Pipe size or depth of tank? • Project tagging?
• Immersion length required?
• Stem length?
• Stem diameter?

➤ SAFETY AND APPLICATION CONSIDERATIONS:


• Use of a thermowell is recommended for pressure, corrosive • Operating conditions – It is recommended the temperature
fluid or high velocity applications. of the thermometer head not exceed 300°F (149°C)
• Use of a thermowell allows removal of thermometer for • Maximum recommended temperature limit for optional
calibration check or interchange of instruments without lens materials:
shutting down the process.
• Install thermometers in locations that minimize injury or Acrylic plastic
damage in the event of an accidental breach of stem/ • 180°F (80°C)
thermowell combination. • Fair chemical resistance but limited temperature limit
• Cases may be silicone filled for additional dampening of Polycarbonate plastic
extreme vibration, or to assure consistent performance in
low process temperature/high environmental humidity • 270°F (130°C)
applications. • Higher temperature limit than acrylic but poor
• Silicone filled thermometers are limited for use with chemical resistance
process temperatures ranging from a minimum of -50°F
(-45°C) to a maximum of 500°F (260°C). Shatterproof laminated safety glass
• Use of silicone fill should be avoided where strong oxidizing • 200°F (90°C)
agents such as oxygen, chlorine, nitric acid, and hydrogen • High corrosion resistance
peroxide are present.
• Plastic laminate between two pieces of glass will hold
• Bimetal thermometers should not be exposed continuously fragments in place if broken but laminate will start to
to process temperatures over 800° F (425° C) to avoid
damaging the bimetal element. deteriorate above 200°F
• For 21/2" stem industrial thermometers: Tempered glass
■ The connection nut should be immersed or in contact • Improved to withstand a broad range of temperature
with the process media for most accurate reading. changes
■ When used with limited space thermowells some • More impact resistant than regular glass
reading error may be noticed depending on process
and ambient temperatures.
Page 4
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

➤ RECOMMENDATIONS FOR CHECKING THE CALIBRATION OF BIMETAL THERMOMETERS:

Use of a MASTER THERMOMETER, at least as accurate as a bimetal thermometer, is recommended for making comparisons.
For best results, use a precision ASTM type mercury-in-glass thermometer certified directly traceable to NIST.
Immersion of the bimetal thermometer stem into the medium must be at least up to the groove on the stem to assure that the
entire bimetal coil is immersed.
• In some short stem Tel-Tru industrial thermometers the groove may be hidden by the threaded connection;
the entire stem and thread should be immersed in this case.

CALIBRATION TEST EQUIPMENT CONSIDERATIONS:


Check the stability and accuracy specifications of this instrumentation, and cross-check the read-outs with NIST traceable
mercury in glass thermometers. Make certain the test instrument is stabilized at the reading point as initial insertion of
thermometer stem into bath/dry block can sometimes have a short-term affect on test device stability.
• Take reading of Bimetal Thermometer when the pointer has stabilized and stopped moving. Typical immersion
time may vary from approximately 1 to 3 minutes depending on type of thermometer, temperature point and
calibration test equipment used.
Use of a laboratory grade CONSTANT TEMPERATURE BATH, with agitation to provide uniform temperature throughout,
is recommended.
• Controls and read-out (if provided) should be properly calibrated and at least as accurate as the bimetal
thermometer being tested.
• Confirm upper and lower limits of bath operating range as accuracy and stability may not be as consistent
at those points.
If using a DRY BLOCK calibration device consider:
• The hole into which thermometer is inserted should allow for minimal air space around stem.
• The temperature profile of the “hole” may affect the reading of the tested bimetal thermometer— if the heat source
is only at the bottom of hole or is not uniform over the length of the bimetal coil. This is compounded with short
stem thermometers.
Tel-Tru Check-Set™ Temperature Calibrators are recommended for verification of thermometer accuracy in food safety and
food service HACCP (Hazardous Analysis Critical Control Points) programs.

★ Please call, fax or e-mail Tel-Tru if you have any questions, require review of process or need assistance. ★

➤ EIGHT YEAR WARRANTY
There is no better guarantee of quality bimetallic dial thermometers than the name Tel-Tru Manufacturing Company. And now, no guarantee lasts longer.
Tel-Tru models AA375R, AA475R, AA575R, BC350R, BC450R, BC550R, GT300R, GT400R, and GT500R carry an EIGHT YEAR guarantee. It’s simple! If the
thermometer covered fails and you have not misused your Tel-Tru Thermometer, simply call us at 1-800-232-5335. We warrant certain designated instruments
(AA375R, AA475R, AA575R, BC350R, BC450R, BC550R, GT300R, GT400R, and GT500R) manufactured and sold by us to be free from defects in material and
workmanship under normal use and service. This warranty shall be null and void if the thermometer is exposed or subjected to: (1) corrosive chemicals, either
environmentally or through manufacturing processes; (2) temperatures in excess of the rated over-temperature limit; or (3) any application which subjects the
thermometer to excessive vibration or causes violation of the stem or case enclosure. Our obligation under this warranty shall be limited to the repair or exchange
of any thermometer which shall be returned to our factory, transportation charges prepaid, within eight (8) years of the date of purchase, and which our examina-
tion shall disclose to be defective due to workmanship or material. This warranty is expressly in lieu of all other warranties expressed or implied (including any
warranty of merchantability and fitness for a particular purpose), and of all other obligations or liabilities on our part for damages, including but not limited to
consequential damages, arising out of the use or misuse of this thermometer, and we neither assume, or authorize any other person to assume for use, any other
liability in connection with the sale of this thermometer or any part thereof. Warranty on all other models is one year under the same conditions as noted above.

Page 5
How to Order

➤ HOW TO ORDER:
EXAMPLE
MODEL CODE STEM LENGTH RANGE
3410 04 59

1) Model Code
2) Connection Size and Thread Type
3) Stem Length
4) Temperature Range
5) State Options and Accessories When Required – See Standard Features and Options Table

➤ MODEL CODES, CONNECTIONS SIZE AND THREAD TYPE


.250" Diameter Stems– Industrial .150" Diameter Stems– Industrial
Dial Size Model NPT Lens Con. Loc. CODE Dial Size Model NPT Lens Con. Loc. CODE
2" (51mm) LN250 1/4" Glass Back 3110 1 3/4" (44mm) GT200 1/8" Glass Back 1910
LN250R 1/4" Glass Back 3210 GT200 1/4" Glass Back 2010
3" (80mm) GT300 1/2" Glass Back 3310 2" (51mm) GT225 1/8" Glass Back 4910
GT300R 1/2" Glass Back 3410 GT225 1/4" Glass Back 491A
MX325R 1/2" Glass Back 3610
MM325R 1/2" Glass Back 5010
BC350R 1/2" Glass Bottom 3910 .150" Diameter Stems– Pocket/Laboratory
AA375R 1/2" Glass Adjustable 4110 Dial Size Model NPT Lens Con. Loc. CODE
4" (100mm) GT400 1/2" Glass Back 4510 1" (25mm) PT50R N/A Plycrb. Back 1210
GT400R 1/2" Glass Back 4810 PT50 N/A Plycrb. Back 1110
BC450R 1/2" Glass Bottom 4610 AD10R N/A Plycrb. Back 1219
AA475R 1/2" Glass Adjustable 4710 1 3/8" (36mm) AD44R N/A Plycrb. Back 4419
5" (128mm) GT500 1/2" Glass Back 3710 1 3/4" (44mm) MT39 N/A Glass Back 1310
GT500R 1/2" Glass Back 3810 MT39R N/A Glass Back 1410
MX525R 1/2" Glass Back 5310 GT100R N/A Glass Back 1610
MM525R 1/2" Glass Back 5410 2" (51mm) LT225R N/A Glass Back 2310
BC550R 1/2" Glass Bottom 4010 LT225 N/A Glass Back 2210
AA575R 1/2" Glass Adjustable 4210 3" (80mm) LT330R N/A Plycrb. Back 2819

➤ STEM LENGTHS ➤ STANDARD TEMPERATURE RANGES


DUAL RANGES
Stem Lengths Code Fahrenheit Code Celsius Code
-21/2" (63mm) 02 -100/100 51 -75/175 87 Fahrenheit Celsius Code
4" (100mm) 04 -50/120 52 -70/70 EA -100/100 -75/40 01
* 5" (128mm) 05 -40/160 53 -50/100 71 -40/160 -40/70 02
6" (152mm) 06 0/140 54 -50/25 72 0/140 -18/60 13
* 8" (203mm) 08 0/180 55 -50/50 73 0/180 -18/82 03
9" (229mm) 09 0/200 50 -40/70 84 0/220 -10/100 04
12" (305mm) 12 0/220 56 -20/120 86 0/250 -20/120 14
15" (381mm) 15 0/250 67 -10/110 74 20/240 -10/110 05
18" (457mm) 18 0/300 57 0/50 75 25/125 0/50 06
24" (610mm) 24 0/500 58 0/60 95 50/300 10/150 07
20/240 59 0/80 EI 50/400 0/200 08
* Laboratory and test 25/125 60 0/100 76
thermometers .150" only 50/500 0/250 09
50/250 61 0/150 77 150/750 50/400 10
50/300 62 0/200 78 200/1000 100/550 11
50/400 63 0/250 79
50/500 64 0/300 80 Availability of temperature ranges
50/550 68 0/400 81 varies by model. Dial size must be
100/800 44 0/450 90 1-3/8" or larger.
150/750 65 100/400 82
200/1000 66 100/550 83

Page 6
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

➤ STANDARD FEATURES AND AVAILABLE OPTIONS

Laboratory and Testing Thermometers Industrial Industrial Thermometers


Head Dia. 1" 13/8" 13/4" 2" 3" 13/4" 2" 2" 3", 4" and 5"
Model PT50 PT50R AD10R AD44R GT100 GT100R LT225 LT225R LT330R GT200 GT225 LN250 AAR BCR GT GTR MMR MXR
(1110) (1210) (1219) (4419) (1510) (1610) (2210) (2310) (2819) (4910) (3110) (3" 4110) (3" 3910) (3" 3310) (3" 3410) (3" 5010) (3" 3610)
LN250R (4" 4710) (4" 4610) (4" 4510) (4" 4810) (5" 5410) (5" 5310)
(3210) (5" 4210) (5" 4210) (5" 3710) (5" 3810)
Glass † † ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔

Glass, Shatterproof O O O O
Lens


Glass, Tempered O O O O O O O O O O O

Plastic, Acrylic O O O O O O O O O
Plastic, Polycarbonate † † ✔ ✔ O O O O ✔ O O O O O O O

.140" O O O O O O O O O O O
.150" ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Stem Diameters


.187" O O O

.236" (6mm) O O O O O O

.250" ✔ ✔ ✔ ✔ ✔ ✔ ✔

.315" (8mm) O O O O O O

.375" O O O O O O O
Bushing, Plain ✔ ✔ ✔ O O O O O O O

Bushing, 1/4" - 20 O O O

Bushing, 1/4" - 28 O O O

Bushing, 3/8" - 24 O O
Nut, Recalibrating ✔ ✔ ✔ ✔ ✔ ✔

Nut, 1/16" NPT O O
Connections

Nut, 1/8" NPT O O


✔(1910) O
Nut, 1/4" NPT O ✔(2010) ✔ ✔ O O O O O O
Nut, 1/4" BSPT O O O(3210) O O O O O O
Nut, 3/8" NPT O ✔(2110) O O O O O O O O

Nut, 3/8" BSPT O O O O O O
Nut, 1/2" NPT O O O O ✔ ✔ ✔ ✔ ✔ ✔

Nut, 1/2" BSPT O(3110) O O O O O O

Union, 1/2" NPT O O O O O O
Other Connections Other connection fittings available upon request.

Silicone Filled O O O O O O O
316SS, Wetted Parts O O O O O O
Options


316SS, All O O O O

Tagging O O O O O O O O O O O O O O O O O O

Custom Dial Imprinting O O O O O O O O O O O O O O O O O O
Stem Lengths Intermediate lengths available upon request. 18" Maximum Intermediate lengths available upon request. 120" Maximum

✔ Standard configuration.
† Polycarbonate lens standard up to 300°F (150°C), Glass lens standard over 300°F (150°C). Do Not subject Polycarbonate lens to temperatures over 270°F (130°C).
O Available options.

Page 7
3", 4" and 5" Adjustable Angle Industrial Thermometers
• Maximum utility for installation • Head can be rotated 360° • Stem positioning over 180°
Heavy Duty design, with versatile case and stem that can be adjusted to almost any angle for easy viewing.
Preferred by the process, offshore, power, pharmaceutical and chemical industries.

➤ MODEL CODES:
AA-375R 3" diameter head with calibration feature
AA-475R 4" diameter head with calibration feature
AA-575R 5" diameter head with calibration feature

➤ SPECIFICATIONS:
Stem Lengths: 21/2", 4", 6", 9", 12", 15", 18" and 24" (available up to 120").
Stem Diameter: .250" standard up to 42" stem.
.375" standard over 42" stem.
Connection: 1
/2" NPT.
External Reset: Easy to calibrate by inserting 1/16" Allen wrench into reset opening.
Construction: 304 stainless steel external parts. Welded construction.
Corrosion resistant to most chemicals.
Hermetic seal: Per ASME B40.3 dustproof and leakproof.
Harness: All stainless steel brackets with screws that loosen to allow 360° rotation of head
and 180° adjustment of stem position.
Bellows: Heavy-duty flexible stainless steel. Hermetically sealed at case and connection.
Protects mechanism that transfers temperature change from bimetal coil to pointer.
Dial: True Anti-Parallax dial, easy-to-read from any angle, minimizes reading errors.
Anodized aluminum with large black numbers and graduations.
Lens: Glass.
Bimetal Coil: Helix coil is silicone coated on ranges below 500°F for vibration dampening and to
maximize heat transfer and response time. MADE IN USA

Accuracy: ±1% full span per ASME B40.3 Grade A. Adjustment of the angle between case and
stem may affect accuracy up to 0.5% of span (ASME B40.3).
Over Temperature
Limits: Up to 250°F 100%; 250°F to 550°F, 50%; 550°F to 1000°F, continuous use up to 800°F,
intermittent use over 800°F.
Page 8
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

➤ STANDARD RANGES: ➤ AA-375R, AA-475R AND AA-575R


Dual
Fahrenheit º/ Div. Celsius º/ Div. Fahrenheit Celsius
-100/100° 2° -75/175° 5° -100/100 -75/40
-50/120° 2° -70/70° 1° -40/160 -40/70
-40/160° 2° -50/100° 1° -0/140 -18/60
0/140° 1° -50/25° 1° 0/180 -18/82
0/180° 2° -50/50° 1° 0/220 -10/100
0/200° 2° -40/70° 1° 0/250 -20/120
0/220° 2° -20/120° 1° 20/240 -10/110
0/250° 2° -10/110° 1° 25/125 -5/50
0/300° 5° 0/50° 1/2° 50/300 10/150
0/500° 10° 0/60° 1° 50/400 0/200
20/240° 2° 0/80° 1/2° 50/500 10/260
25/125° 1° 0/100° 1° 150/750 50/400
50/250° 2° 0/150° 1° * 200/1000 * 100/550
50/300° 2° 0/200° 2°
50/400° 5° 0/250° 2°
50/500° 5° 0/300° 5°
50/550° 5° 0/400° 5°
100/800° 10° 0/450° 5°
150/750° 10° 100/400° 5°
* 200/1000° 10° * 100/550° 5°
(Additional Ranges Available – Consult factory)
* Thermometers with temperature ranges 200/1000°F and 100/550°C are
NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800°F/425°C
(FOR INTERMITTENT USE ONLY).

➤ OPTIONS:
• Union connection or other connection types and sizes.
• Silicone filled.
• Other lenses are acrylic, polycarbonate, shatterproof glass
or tempered glass.
• Other stem diameters .236" (6mm), .315" (8mm),
.375" (9.52mm).
• 316SS wetted parts.
• Other configuration combinations available upon request.
MODEL "A" "B"
Estimated Shipping Weights
MODEL DRY SILICONE FILLED AA-375R 2.430" (61.72mm) 3.187" (80.95mm)
AA-375R . . 1lb. . . . . . . . . 1lb. 3oz. AA-475R 2.430" (61.72mm) 4.115" (104.50mm)
AA-475R . . 1lb. 8oz.. . . . .1lb. 14oz.
AA-575R . . 1lb. 12oz.. . . .2lb. 6oz. AA-575R,
UT575 2.660" (67.56mm) 5.040" (128.02mm)
** Contact factory if specific dimension is required
for OEM applications.

➤ FOR HOW TO ORDER, SEE PAGE 6

➤ IMPORTANT NOTES:
1) Thermowells are recommended for pressure, corrosive fluid or high velocity applications.
2) ASME B40.3— Bimetal thermometers manufactured by Tel-Tru and offered in this brochure are designed to meet or exceed this
Standard issued by the American Society of Mechanical Engineers.

Page 9
3", 4" and 5" Back Connected Industrial Thermometers
A rugged 90° back angle, rear threaded connection design. Commonly used in industrial, pulp and
paper, food and beverage processing, HVAC, and OEM applications.

➤ MODEL CODES:
GT-300 3" diameter head
GT-300R 3" diameter head with calibration feature
MX-325R 3" diameter head with calibration feature and min
or max temperature indicator
MM-325R 3" diameter head with calibration feature and min
and max temperature indicator
GT-400 4" diameter head
GT-400R 4" diameter head with calibration feature
GT-500 5" diameter head
GT-500R 5" diameter head with calibration feature
MX-525R 5" diameter head with calibration feature and min
or max temperature indicator
MM-525R 5" diameter head with calibration feature and min
and max temperature indicator

➤ SPECIFICATIONS:
Stem Lengths: 21/2", 4", 6", 9", 12", 15", 18" and 24" (available up to 120").
Stem Diameter: .250" standard up to 42" stem.
.375" standard over 42" stem.
Connection: 1
/2" NPT.
External Reset: Models with calibration feature are easy to calibrate by inserting
1
/16" Allen wrench into reset opening.
Construction: 304 stainless steel external parts. Welded construction.
Corrosion resistant to most chemicals.
Hermetic seal: Per ASME B40.3 dustproof and leakproof.
Dial: True Anti-Parallax dial, easy-to-read from any angle, minimizes reading errors.
Anodized aluminum with large black numbers and graduations.
Lens: Glass.
Bimetal Coil: Helix coil is silicone coated on ranges below 500°F for vibration dampening and to
maximize heat transfer and response time. MADE IN USA
Accuracy: ±1% full span per ASME B40.3 Grade A. When using maximum or
minimum temperature indicator, accurate to within 11/2% full span.
Over Temperature
Limits: Up to 250°F 100%; 250°F to 550°F, 50%; 550°F to 1000°F, continuous use up to 800°F,
intermittent use over 800°F.

Page 10
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

➤ STANDARD RANGES: ➤ GT-300, GT-300R, GT-400, GT-400R, GT-500,


Dual GT-500R, MX-325R, MM-325R, MX-525R, MM-525R
Fahrenheit º/ Div. Celsius º/ Div. Fahrenheit Celsius
-100/100° 2° -75/175° 5° -100/100 -75/40
-50/120° 2° -70/70° 1° -40/160 -40/70
-40/160° 2° -50/100° 1° -0/140 -18/60
0/140° 1° -50/25° 1° 0/180 -18/82
0/180° 2° -50/50° 1° 0/220 -10/100
0/200° 2° -40/70° 1° 0/250 -20/120
0/220° 2° -20/120° 1° 20/240 -10/110
0/250° 2° -10/110° 1° 25/125 -5/50
0/300° 5° 0/50° 1/2° 50/300 10/150
0/500° 10° 0/60° 1° 50/400 0/200
20/240° 2° 0/80° 1/2° 50/500 10/260
25/125° 1° 0/100° 1° 150/750 50/400
50/250° 2° 0/150° 1° * 200/1000 * 100/550
50/300° 2° 0/200° 2°
50/400° 5° 0/250° 2°
50/500° 5° 0/300° 5°
50/550° 5° 0/400° 5°
100/800° 10° 0/450° 5°
150/750° 10° 100/400° 5°
* 200/1000° 10°
* 100/550° 5°
(Additional Ranges Available – Consult factory)
* Thermometers with temperature ranges 200/1000°F and 100/550°C are
NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800°F/425°C
(FOR INTERMITTENT USE ONLY).

➤ OPTIONS:
• Union connection or other connection types and sizes.
• Silicone filled.
• Other lenses are acrylic, polycarbonate, shatterproof glass
or tempered glass (except MX and MM models).
• Other stem diameters .236" (6mm), .315" (8mm), .375" MODEL "A" "B" "C" "D"
(9.5mm).
• 316SS wetted parts. GT-300, GT-300R 1.375" (34.93mm) 3.187" (80.95mm) N/A N/A

• Other configuration combinations available upon request. GT-400, GT-400R 1.375" (34.93mm) 4.115" (104.50mm) N/A N/A

• Some ranges NSF® certified. GT-500, GT-500R,


UT500
1.718" (43.63mm) 5.040" (128.02mm) N/A N/A

MX-325R 1.375" (34.93mm) 3.187" (80.95mm) .500" (12.70mm) .275" (6.99mm)


Estimated Shipping Weights
MODEL DRY SILICONE FILLED MM-325R 1.375" (34.93mm) 3.187" (80.95mm) .625" (15.88mm) .438 (11.12mm)
GT-300 and GT-300R. . 11 oz.. . . . . . 14 oz. MX-525R 1.718" (43.63mm) 5.040" (128.02mm) .500" (12.70mm) .275" (6.99mm)
GT-400 and GT-400R. . 1 lb. . . . . . . . 1 lb. 6 oz.
GT-500 and GT-500R. . 1 lb. 4 oz.. . . 1 lb. 14 oz. MM-525R 1.718" (43.63mm) 5.040" (128.02mm) .625" (15.88mm) .438 (11.12mm)
MX-325R and MM-325R.11 oz.. . . . . . N/A
MX-525R and MM-525R.1 lb. 4 oz.. . . N/A

➤ FOR HOW TO ORDER, SEE PAGE 6

➤ IMPORTANT NOTES:
1) Thermowells are recommended for pressure, corrosive fluid or high velocity applications.
2) ASME B40.3— Bimetal thermometers manufactured by Tel-Tru and offered in this brochure are designed to meet or exceed this
Standard issued by the American Society of Mechanical Engineers.
Page 11
3", 4" and 5" Bottom Connected Industrial Thermometers
A sturdy straight form design commonly used for industrial applications and OEM equipment.

➤ MODEL CODES:
BC-350R 3" diameter head with calibration feature
BC-450R 4" diameter head with calibration feature
BC-550R 5" diameter head with calibration feature

➤ SPECIFICATIONS:
Stem Lengths: 21/2", 4", 6", 9", 12", 15", 18" and 24" (available up to 120").
Stem Diameter: .250" standard up to 42" stem.
.375" standard over 42" stem.
Connection: 1
/2" NPT.
External Reset: Easy to calibrate by inserting Allen wrench into reset opening.
Construction: 304 stainless steel external parts. Welded construction.
Corrosion resistant to most chemicals.
Hermetic seal: Per ASME B40.3 dustproof and leakproof.
Dial: True Anti-Parallax dial, easy-to-read from any angle, minimizes reading errors.
Anodized aluminum with large black numbers and graduations.
Lens: Glass.
Bimetal Coil: Helix coil is silicone coated on ranges below 500°F for vibration dampening
and to maximize heat transfer and response time.
Accuracy: ±1% full span per ASME B40.3 Grade A.
Over Temperature
Limits: Up to 250°F 100%; 250°F to 550°F, 50%; 550°F to 1000°F, continuous use up to 800°F, MADE IN USA

intermittent use over 800°F.

Page 12
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

➤ STANDARD RANGES: ➤ BC-350R, BC-450R AND BC-550R


Dual
Fahrenheit º/ Div. Celsius º/ Div. Fahrenheit Celsius
-100/100 2° -75/175 5° -100/100 -75/40 Positions
-50/120 2° -70/70 1° -40/160 -40/70 Available
-40/160 2° -50/100 1° 0/140 -18/60
0/140 1° -50/25 1° 0/180 -18/82
0/180 2° -50/50 1° 0/220 -10/100
0/200 2° -40/70 1° 0/250 -20/120
0/220 2° -20/120 1° 20/240 -10/110
0/250 2° -10/110 1° 25/125 -5/50
0/300 5° 0/50 1/2° 50/300 10/150
0/500 10° 0/60 1° 50/400 0/200
20/240 2° 0/80 1/2° 50/500 10/260
25/125 1° 0/100 1° 150/750 50/400 Standard
50/250 2° 0/150 1° * 200/1000 * 100/550
50/300 2° 0/200 2°
50/400 5° 0/250 2°
50/500 5° 0/300 5°
50/550 5° 0/400 5°
100/800 10° 0/450 5°
150/750 10° 100/400 5°
* 200/1000 10° * 100/550 5°
(Additional Ranges Available – Consult factory)
* Thermometers with temperature ranges 200/1000°F and 100/550°C are
NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800°F/425°C
(FOR INTERMITTENT USE ONLY).

➤ OPTIONS:
• Stem Position available in TOP (12:00), RIGHT (3:00),
or LEFT (9:00) side connections (specify position of
stem when ordering).
• Union connection or other connection types and sizes.
• Silicone filled.
• Other lenses are acrylic, polycarbonate, shatterproof
glass or tempered glass.
• Other stem diameters .236" (6mm), .315" (8mm),
.375" (9.5mm).
• 316SS wetted parts.
• Other configuration combinations available upon request.
MODEL "A" "B" "C"
Estimated Shipping Weights
MODEL DRY SILICONE FILLED BC-350R 1.187" (30.15mm) 3.187" (80.95mm) 2.300" (58.42mm)
BC-350R. . 14 oz. . . . . . . 1 lb. 1 oz. BC-450R 1.187" (30.15mm) 4.115" (104.50mm) 3.000" (76.20mm)
BC-450R. . 1 lb. 3 oz. . . . 1 lb. 9 oz.
BC-550R. . 1 lb. 10 oz. . . 2 lb. 4 oz. BC-550R 1.625" (41.28mm) 5.040" (128.02mm) 3.000" (76.20mm)

➤ FOR HOW TO ORDER, SEE PAGE 6

➤ IMPORTANT NOTES:
1) Thermowells are recommended for pressure, corrosive fluid or high velocity applications.
2) ASME B40.3— Bimetal thermometers manufactured by Tel-Tru and offered in this brochure are designed to meet or exceed this
Standard issued by the American Society of Mechanical Engineers.

Page 13
13/4" and 2" Back Connected Industrial Thermometers
A smaller size, heavy duty, rear connected unit commonly used in OEM equipment and light
industrial applications.

GT-200
(With 13/4" dial)

LN-250
(With 2" dial)

➤ MODEL CODES:
GT-200 13/4" diameter head
GT-225 2" diameter head
LN-250 2" diameter head
LN-250R 2" diameter head with calibration feature

➤ SPECIFICATIONS:
Stem Lengths: GT Models 21/2", 4", 6", 8", 12", and 18".
LN Models 21/2", 4", 6", 9", 12", 15", 18" and 24" (available up to 120").
Stem Diameter: GT model .150" standard up to 18" stem.
LN model .250" standard up to 42" stem.
LN model .375" is standard over 42" stem.
Connection: GT models 1/8", 1/4", or 3/8" NPT is standard.
LN models 1/4" NPT is standard.
External Reset: LN-250R is easy to calibrate by loosening the socket head screw
(above hex connecting nut) with 5/64" Allen wrench.
Construction: 304 stainless steel external parts. Welded construction.
Corrosion resistant to most chemicals.
Hermetic seal: Per ASME B40.3 dustproof and leakproof.
Dial: Anodized aluminum with large black numbers and graduations.
Lens: Glass.
Bimetal Coil: Helix coil is silicone coated on ranges below 500°F for vibration dampening
and to maximize heat transfer and response time.
Accuracy: ±1% full span per ASME B40.3 Grade A. MADE IN USA

Over Temperature
Limits: Up to 250°F 100%; 250°F to 550°F, 50%; 550°F to 1000°F, continuous use
up to 800°F, intermittent use over 800°F.

Page 14
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

➤ STANDARD RANGES: ➤ GT-200, GT-225, AND LN-250


Dual
Fahrenheit º/ Div. Celsius º/ Div. Fahrenheit Celsius
-100/100 2° -75/175 5° -100/100 -75/40
-50/120 2° -50/100 1° -40/160 -40/70
-40/160 2° -50/25 1° 0/140 -18/60
0/140 2° -50/50 1° 0/180 -18/82
0/180 2° -40/70 1° 0/220 -10/100
0/200 2° -20/120 1° 0/250 -20/120
0/220 2° -10/110 1° 20/240 -10/110
0/250 2° 0/50 1/2° 25/125 0/50
20/240 2° 0/100 1° 50/300 10/150
25/125 1° 0/150 1° 50/400 0/200
50/250 2° 0/200 2° 50/500 0/250
50/300 2° 0/250 2° 150/750 50/400
50/400 5° 0/300 5° * 200/1000 * 100/550
50/500 5° 0/400 5°
50/550 5° 100/400 5°
150/750 10° * 100/550 5°
*
200/1000 10°

(Additional Ranges Available – Consult factory)


* Thermometers with temperature ranges 200/1000°F and 100/550°C are MODEL "A" "B" "C"
NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800°F/425°C GT-200 .350" (8.89mm) 1.750" (44.45mm) .150" (3.81mm)
(FOR INTERMITTENT USE ONLY).
GT-225 .438" (11.13mm) 2.089" (53.06mm) .150" (3.81mm)
LN-250 .438" (11.13mm) 2.089" (53.06mm) .250" (6.35mm)

➤ OPTIONS:
• Other threaded or plain connections. ➤ LN-250R
• Silicone filled.
• Other lenses are acrylic, polycarbonate or tempered glass.
• Other stem diameters GT-200/GT225 .140" (3.6mm)
models. LN-250 .236" (6mm) and .375" (9.5mm).
• Other configuration combinations available upon request.

Estimated Shipping Weights


MODEL DRY SILICONE FILLED
GT-200. . . . . 3 oz. . . . . . . . . N/A
GT-225. . . . . 3 oz. . . . . . . . . 5 oz.
LN-250
and LN-250R.5 oz. . . . . . . . . 9 oz.

➤ FOR HOW TO ORDER, SEE PAGE 6

➤ IMPORTANT NOTES:
1) Thermowells are recommended for pressure, corrosive fluid or high velocity applications.
2) ASME B40.3— Bimetal thermometers manufactured by Tel-Tru and offered in this brochure are designed to meet or exceed this
Standard issued by the American Society of Mechanical Engineers.

Page 15
13/4", 2" and 3" Laboratory Testing and General Purpose Thermometers
These models are used for general-purpose testing applications such as laboratory, food, concrete,
asphalt, soil and photography and OEM equipment.

LT-330R
(With 3" dial)

GT100R LT-225R
(With 13/4" dial) (With 2" dial)

➤ MODEL CODES:
GT-100 and MT-39 13/4" diameter head
GT-100R and MT-39R 13/4" diameter head with calibration feature
LT-225 2" diameter head
LT-225R and BT-275R 2" diameter head with calibration feature
LT-330R 3" diameter head with calibration feature

➤ SPECIFICATIONS:
Stem Lengths: 5", 8", 12" and 18".
Stem Diameter: .150" standard up to 18" stem.
Connection: GT-100, MT-39 and LT-225 plain bushing is standard.
GT-100R, MT-39R, LT225R, BT-275R and LT-330R
recalibrating nut is standard.
External Reset: GT-100R, MT-39R, LT-225R, BT-275R and LT-330R
friction nut design for easy calibration.
Construction: 304 stainless steel external parts. Welded construction.
Corrosion resistant to most chemicals.
Hermetic seal: Per ASME B40.3 dustproof and leakproof.
Dial: Anodized aluminum with large black numbers and graduations.
Lens: GT, MT, and LT models glass is standard.
LT-330R polycarbonate lens is standard.
Bimetal Coil: Helix coil is silicone coated on ranges below 500°F for vibration
dampening and to maximize heat transfer and response time.
Accuracy: ±1% full span per ASME B40.3 Grade A. MADE IN USA

Over Temperature
Limits: Up to 250°F 100%; 250°F to 550°F, 50%; 550°F to 1000°F, continuous use
up to 800°F, intermittent use over 800°F.
Adjustable Pan Clip: Standard on 5" and 8" GT-100R, LT-225R and LT-330R (for tank and tray mounting).

Page 16
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

➤ STANDARD RANGES 13/4" AND 2" MODELS: ➤ GT-100R, MT-39R, BT-275R AND LT-225R
Dual
Fahrenheit º/ Div. Celsius º/ Div. Fahrenheit Celsius
-100/100 2° -75/175 5° -100/100 -75/40
-50/120 2° -50/100 1° -40/160 -40/70
-40/160 2° -50/25 1° 0/140 -18/60
0/140 2° -50/50 1° 0/180 -18/82
0/180 2° -40/70 1° 0/220 -10/100
0/200 2° -20/120 1° 0/250 -20/120
0/220 2° -10/110 1° 20/240 -10/110
0/250 2° 0/50 1/2° 25/125 0/50
20/240 2° 0/100 1° 50/300 10/150
25/125 1° 0/150 1° 50/400 0/200 MODEL "A" "B" "C"
50/250 2° 0/200 2° 50/500 0/250
GT-100R, MT-39R .412" (10.47mm) 1.750" (44.45mm) .102" (2.59mm)
50/300 2° 0/250 2° 150/750 50/400
50/400 5° 0/300 5° * 200/1000 * 100/550 LT-225R, BT-275R .438" (11.13mm) 2.089" (53.06mm) .120" (3.05mm)
50/500 5° 0/400 5°
50/550 5° 100/400 5°
150/750 10° * 100/550 5°
* 200/1000 10° ➤ GT-100, MT-39, and LT-225
➤ DUAL TEMPERATURE RANGES
MODEL LT-330R:
Est. Shipping Weights
Fahrenheit º/ Div. Celsius º/ Div. MODEL DRY
-100/100 2° -75/40 2° MT-39 and MT-39R. . . . . 4 oz.
-40/160 2° -40/70 1° GT-100 and GT-100R. . . 3 oz.
0/220 2° -10/100 1° LT-225 and LT-225R. . . . 4 oz.
25/125 1° 0/50 1/2° LT-330R and BT-275R. . 8 oz.
50/300 2° 10/150 2°
50/500 5° 0/250 2°
150/750 10° 50/400 5° MODEL "A" "B" "C"
* 200/1000 10° * 100/550 5°
GT-100, MT-39 .350" (8.89mm) 1.750" (44.45mm) .187" (4.75mm)
Notes for above tables:
(Additional Ranges Available– Consult factory) LT-225 .438" (11.13mm) 2.089" (53.06mm) .250" (6.35mm)
* Thermometers with temperature ranges 200/1000°F and 100/550°C are
NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800°F/425°C
(FOR INTERMITTENT USE ONLY).
➤ LT-330R
➤ OPTIONS:
• Threaded connections on non-recal models.
• Other lenses are acrylic, polycarbonate or tempered glass.
• Other stem diameters .140" (3.6mm) and .187" (4.7mm).
• Pocket sheath for 5" or 8" stem.
• Silicone fill on LT225 and LT225R.
• Other configuration combinations available upon request.

➤ FOR HOW TO ORDER, SEE PAGE 6

➤ IMPORTANT NOTES:
1) IMMERSION– For most accurate reading with Tel-Tru thermometers immerse past groove on lower portion of stem.
2) MT and BT models are designed with Tel-Tru unique pressure relief ring feature designed to prevent pressure build up
in thermometer head while cooking in hot oven.
3) Some models and ranges are NSF® certified (National Sanitation Foundation).
Page 17
1" and 13/8" Testing and Spot Checking Thermometers
A pocket sized thermometer used by inspectors, service and maintenance personnel, and technicians for
general checking in food service, refrigeration, air conditioning, hot asphalt and food processing
applications. Often modified for OEMs to use in limited space situations.

PT-50R
(Standard dial,
with 1" dial)

AD-44R PT-50R
(Standard, (Shown with
with 13¼8" dial) pocket sheath)

➤ MODEL CODES:
PT-50 1" diameter head
PT-50R 1" diameter head with calibration feature
AD-10R 1" diameter head with calibration feature
AD-44R 13¼8" diameter head with calibration feature
MADE IN USA
➤ SPECIFICATIONS:
Stem Length: 5" (127mm)
Stem Diameter: .150"
Connection: PT-50 model plain bushing is standard.
PT-50R, AD10R and AD44R recal nut is standard.
External Reset: PT50R, AD10R, AD44R and MT39R friction nut design for easy calibration.
Construction: 304 stainless steel external parts. Welded construction.
Corrosion resistant to most chemicals.
Hermetic seal: Per ASME B40.3 dustproof and leakproof.
Dial: Anodized aluminum with large black numbers and graduations. Glow dial
available on PT50R and AD44R.
Lens: AD10R and AD44R models polycarbonate lens is standard.
PT50 and PT50R models polycarbonate lens is standard up to 300°F (150°C) and glass
lens over 300°F (150°C).
Bimetal Coil: Helix coil is silicone coated on ranges below 500°F for vibration dampening and to
maximize heat transfer and response time.
Accuracy: ±1% full span per ASME B40.3 Grade A.
Over Temperature
Limits: Up to 250°F 100%; 250°F to 550°F, 50%; 550°F to 1000°F, continuous use
up to 800°F, intermittent use over 800°F.
Pocket sheath: Standard on 5" PT50R, AD10R and AD44R.

Page 18
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

➤ STANDARD RANGES: ➤ PT-50

Fahrenheit º/ Division Celsius º/ Division


* -40/160 2° -40/70 1°
25/125 1° -10/110 1°
* 0/220 2° 0/50 1/2°
* 50/500 5° 0/250 5°
150/750 10°

(Additional Ranges Available– Consult factory)


* NSF® approved for food service applications on models
PT-50R, AD-10R and AD-44R

➤ OPTIONS: ➤ PT-50R
• .140" stem diameter.
• Threaded connections for OEM applications.
• Other configuration combinations available upon request.
• Glow dial available on PT50R and AD44R.

Estimated Shipping Weights


MODEL DRY
PT-50 and PT-50R. . . . 1 oz.
AD-10R. . . . . . . . . . . . . 1 oz.
AD-44R. . . . . . . . . . . . . 2 oz. ➤ AD-10R AND AD-44R

MODEL "A" "B"


AD-10R .400" (10.16mm) 1.004" (25.50mm)
AD-44R .456" (11.58mm) 1.358" (34.50mm)

➤ FOR HOW TO ORDER, SEE PAGE 6

➤ IMPORTANT NOTES:
1) IMMERSION – For most accurate reading with Tel-Tru thermometers immerse past groove on lower portion of stem.
2) CAUTION – Do not subject polycarbonate lens to temperatures above 270°F (130°C).

Page 19
Options and Accessories

➤ CONNECTIONS AND FITTINGS ➤ LENSES ➤ DIALS


Many thread types and sizes are Shatterproof and tempered glass, Precision pad printing of custom logos,
manufactured on Tel-Tru CNC acrylic and polycarbonate plastic. colored zones and special information
machines. 304SS and 316SS. on all dial sizes.

➤ TAGGING ➤ MOUNTING FLANGES


Paper, aluminum, 304SS or 316SS tags Various size mounting flanges for OEM
for engineering project requirements. and duct applications.

➤ THERMOWELL ADAPTER KIT:


The AS-86 adapter kit was designed as a simple means of converting existing Industrial Glass Thermometer Wells for use with
Bimetal Thermometers.

MERCURY

Page 20
Thermowells
Recommended for pressure, corrosive fluid and high velocity applications.

➤ SEE TEL-TRU THERMOWELL CATALOG


For complete dimensions, sizes, available materials, optional features and configurations. For technical data on pressure and
temperature ratings and maximum fluid velocity see http://www.teltru.com

➤ THREADED

Stepped Straight

Tapered Limited Space

➤ FLANGED

Straight Heavy Duty Tapered

➤ WELDED

Socket Weld Weld-In

➤ SANITARY ➤ VAN STONE

Page 21
Special Configuration and Application Thermometers
Tel-Tru bimetal thermometers are manufactured in the USA.

➤ OEM THERMOMETERS
• Custom manufactured from standard or special components. OPTIONS:
• Flexible in meeting custom requirements. • Dials-Custom Imprinting - Name, logo,
• Just-in-time delivery schedules. zones, colors
• Quantities– one unit or thousands. • Temperature Ranges - Over 120 available
• Multiple option configurations available depending on model (varies by dial sizes)
type, dial size, temperature range and applications. • Accuracy - As required for application
• Stem Lengths - Standards, intermediate, or
extra short
• Connections - Plain, threaded, or special
• Certificates - Compliance, Accuracy etc.
• Lens - Standard or optional materials
• Silicone Filled or Silicone Free
• Tagging
• Special Testing
NOTE: Minimum quantities may be required
for some options.

➤ HEAVY DUTY MARINE THERMOMETERS


STANDARD FEATURES
• Shock and vibration resistant. ➤ BC-350R HD
• Stainless steel construction.
• Plastic lens.
• Anti-parallax dial for easy reading.
➤ GT-300R HD ➤THERMOWELL
• External recalibration adjustment. HD-MARINE
• Accurate to 1% of scale range when
testing without well.
• Interchangeable with 5" scale size
“submarine” thermometers
having same stem length.
• 3/4" - 28 UN-2A union connection
assembly MUST be used with
thermowell or bushing.
• Does not comply with MIL I-17244E.

Page 22
Tel-Tru® Manufacturing Company
408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857 • E-mail: [email protected] • Web: www.teltru.com

➤ SILICONE FILLED THERMOMETERS

• Cases may be silicone filled for additional dampening of extreme vibration, or to


assure consistent performance in low process temperature/high environmental
humidity applications.
• Available on all 2", 3", 4" and 5" industrial thermometers and LT-225/LT-225R.
• Silicone filled thermometers are recommended for use with process temperatures
ranging from a minimum of -50°F (-45°C) to a maximum of 500°F (260°C).
• Use of silicone fill should be avoided where strong oxidizing agents such as oxygen,
chlorine, nitric acid, and hydrogen peroxide are present.

➤ THERMOMETERS WITH HEAVY DUTY POINTED STEMS AND DETACHABLE HANDLE

APPLICATIONS:
• Compost/Windrow Testing
• Soil/Asphalt Testing
• Meat Processing
• Mushroom Growing
• Can be used with / " NPT connection.
1 2

• Stem diameter .250" or .375" (recommended).


• Stem diameter .375" with .250" tapered rod available.

➤ SANITARY BIMETAL THERMOMETERS

• Heavy duty thermometers meet 3A Standard Number 74-03


• Tri-Clamp® sanitary fittings are integral to the thermometers
• Constructed of 316L SS wetted parts and 304SS non-contact parts
• Configurations include back connected, bottom connected, and adjustable angle models in
a variety of dial sizes and stem lengths
• Hermetically sealed per ASME B40.3
• Ideal for the dairy processing industry, as well as food and beverage processing and
pharmaceutical industries
For additional specifications, go to www.teltru.com/s-59-sanitary-bimetal.aspx

Tri-Clamp is a registered trademark of Tri-Clover, Inc.

Page 23
Special Application Thermometers

➤ GLOW DIAL AND REFLECTIVE THERMOMETERS

• 5" Adjustable Angle or Back Connect


• Glow dial is luminescent coated aluminum
• Aluminum Reflective Pointer
• Two 304SS Reflective Clips snap onto the dial rim.
You decide where you want to
set each reflective clip--minimum and maximum limits can be indicated, which
allows for on the spot customization
• Glow dials also available on models AD-10R and AD-44R (without clips)
This remarkably easy solution permits anyone viewing the thermometer, up close in
the light of day or far away at night, to easily see if the process is operating within a
designated safe zone. The thermometer can be read from a distance in low light
conditions; all you need is a flashlight!

5" GLOW DIAL RANGES


Range °/Div. Code

0/250°F 2° 67
0/300°F 5° 57
0/500°F 5° 58
20/240°F 2° 59
50/300°F 2° 62
50/400°F 5° 63
50/500°F 5° 64 PT-50R
UT575 UT500 50/550°F 5° 68
Glow dial option,
Adjustable Back Connect, with 1" dial
Angle, Model Model Code 150/750°F 10° 65
Code 641T 621T 200/1000°F 10° 66
For dimensions and ranges,
see page 19.
-50/120°F, -45/50°C 2°, 1° 25
-40/160°F, -40/70°C 2°, 1° 02
For dimensions, see page 9 (UT575) or page 11 0/250°F, -20/120°C 2°, 2° 14
(UT500). 50/500°F, 0/250°C 5°, 2° 09
For additional specifications, go to 0/100°C 1° 76
www.teltru.com/s-16-glow-dial-reflective.aspx 0/150°C 1° 77
0/200°C 2° 78
0/250°C 2° 79

➤ MINIMUM AND MAXIMUM THERMOMETERS


User can easily set red and/or blue lazy hands so that minimum and/or maximum temperatures reached by a process will be indicated.
• MM models indicate both maximum AND minimum.
• MX models indicate maximum OR
minimum only.
• 3" dia. or 5" dia. back connected with
recalibration feature.

MX-325R MM-525R
(With 3" dial) (With 5" dial)

Page 24
Special Application Thermometers
and Check-Set™ Thermometer Calibrators

➤ FOOD SERVICE THERMOMETERS


Tel-Tru offers a variety of NSF® approved Food Service
Thermometers for Food/Beverage Processing, Food
Service, Barbecue, Cooking, OEM Equipment and Retail.

APPLICATIONS
• Meat and Poultry Testing and Cooking
• Professional Food Testing
• Pocket Spot Check
• Gourmet
• Barbecue Pit and Grill
• Deep Fry/Candy

For additional specifications, go to


www.teltru.com/s-44-food-service.aspx

➤ CHECK-SET™ THERMOMETER CALIBRATORS


Environmental Safety and Health Professionals, Quality Assurance Managers and HACCP Coordinators in food processing/smoking, pre-
paring/cooking, holding/serving and cooling/storage are using Check-Set Thermometer Calibrators to verify the accuracy of their dial and
digital thermometers.

CHECK AND CALIBRATE AT YOUR CRITICAL TEMPERATURE POINT

• 40°F and 160°F / 5°C and 90°C - Dual cold and hot units. • Each unit serialized and certified traceable to
• 40°F - Low temperature holding. the National Institute for Standards and Testing.
• 140°F - High temperature holding. • Built in circuitry to warn if unit is more than 1°F
• 160°F - Temperature at which E. Coli and other out of calibration.
pathogens are killed. • Optional factory re-certification and
• 212°F - Point of boiling water maintenance program.

GENERAL CHECK-SET THERMOMETER CALIBRATOR


SPECIFICATIONS:
Accuracy: ±0.2°F
Stability: ±0.06°F to ±0.09°F
Heating Time: Approximately 3 – 8 minutes (varies with temperature
set point)
Stem Diameter: Up to .150"
Voltage: 90 to 130 VAC, 50/60 Hz
Power: 25 – 45 Watts
Weight: 8.9 to 9.2 lbs.
Housing Mat.: Stainless Steel 304SS
Size: 3-1/16" H x 6-5/8" W x 10-7/8"D (78 mm x 168 x 276 mm)
NOTE: Other custom temperature models available
For additional specifications, go to www.teltru.com/s-46-calibrator.aspx

Page 25
Additional Products
available from Tel-Tru®

Sanitary Bimetal Thermometers

Sanitary and Industrial RTDs

Sanitary and Industrial RTDs with Compact


Transmitters

Glow Dial Thermometers

Digi-Tel Thermometers

Thermowells

HVAC Instruments

Gas Actuated Thermometers

Vapor Tension Thermometers

Thermometer Calibrators

Non-Contact Thermometers

Surface Thermometers

Pressure Transmitters

Pressure Gauges

Sanitary Pressure Gauges

Solar Digital Pressure Gauges

Tel-Tru is a registered trademark


of Tel-Tru Manufacturing Co.

Tel-Tru® Manufacturing Company


408 St. Paul St., Rochester, New York 14605 USA
Phone: 585.232.1440 • 800.232.5335 • Fax: 585.232.3857
E-mail: [email protected] • Web: www.teltru.com