Glosser Site Specifications

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

Kodak NexGlosser

glossing unit
Site Specifications
Edition November 11, 2005
Order No.: k3801641
Publication ID: W20G00

ABC

Imprint/Company Address

2005 Kodak. All rights reserved.

NexPress Solutions, Inc.


2600 Manitou Road
Rochester, New York 14653
USA
www.nexpress.com
. ...........................................................
No part of this book may be reproduced without prior written permission.

Kodak, NexPress, NexBlanket,


NexGlosser, NexPert, NexQ,
NexStation and NexTreme are
trademarks of Kodak.

marks or registered trademarks of


the corresponding manufacturers
and fall within the regulations
regarding the protection of trademarks.

Other company names, product


names and trademarks not expressly
mentioned in this manual are trade. ............................................................
Important notice:
We are dedicated to improving and
enhancing our products. Consequently, the information in this
manual is subject to change without
notice.
NexPress Solutions, Inc. assumes no
responsibility for information and
description as far as third-party
products are concerned.
The information contained in this
manual about performance and
speed as well as technical data concerning application of our products

is not legally binding as it does not


constitute a written contract of features.
If any problems occur with the product described in this manual, please
contact the NexPress agency which
is responsible for you.
Order No.: k3801641
Publication ID: W20G00
Edition November 11, 2005
Internal ID: r003
English Source: r003
Printed in USA.

Table of Contents
Table of Contents
Table of Contents
Before You Start ...
About this documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
Structure of this documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
Who should use this manual? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
Important information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
Your comments on this documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VI
Whats new in this edition of the Site Specifications? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VI
NexPress on-line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VI
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VI
1

Physical Dimensions
Requirements for glossing units with serial numbers 0 - 199 . . . . . . . . . . . . . . . . . . . . . . . . . 11
Room requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service accesses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Requirements for glossing units with serial numbers 200 and above . . . . . . . . . . . . . . . . . .
Room requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service accesses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13
13
13
14
14
16
16
16

Electrical & Environmental Requirements


Electrical requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ambient humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21
21
21
21
21

Network Specifications
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31
31
31
31
31

NexGlosser glossing unit Site Specifications

III

Before You Start ...


Before You Start ...

About this documentation


This document describes all specifications for the installation site of the Kodak
NexGlosser glossing unit including:
0

physical dimensions

electrical requirements

environmental requirements

networking requirements

Structure of this documentation


This document is divided into the following sections:
0

Physical Dimensions (page 11)

Electrical Requirements (page 21)

Network Specifications (page 31)

Who should use this manual?


This manual is intended for the following persons:
0

end users

service personnel

sales and marketing personnel

architects and site planners

engineers and contractors including:


0

construction workers

electricians

plumbers

heating, venting, and air conditioning technicians

Important information
Important information in the text is marked by symbols which indicate the following:

3
1
2

Warning: Contains information that must be taken into consideration to protect the
user from injury.

Attention: Contains information that must be taken into consideration to prevent


damage to hardware or software.

Note: Contains important general or supplementary information about a specific


topic.

NexGlosser glossing unit Site Specifications

Before You Start ...

Your comments on this documentation


We would like to know if this documentation meets your requirements:
0

Can you find the information you are looking for (and quickly enough)?

Does it help you to solve any problems which might occur?

Is the structure of the documentation clear to you?

Where do you think there is room for improvement?

Did you find any errors in the documentation? If so, where?


Please feel free to send your comments, criticism and suggestions to us at the following
e-mail address:
[email protected]
It would help us if you could write your comments in English.

Note: This e-mail address should only be used to send us comments about the
documentation, not the glossing unit.

Whats new in this edition of the Site Specifications?


The following modifications and additions have been implemented in the Site Specifications since the last edition dated June 15, 2005:
0

The dimensional information, room layout illustrations, and service access required
for the glossing unit were separated into 2 different serial number ranges: 0-199 and
200 and above.
For further information, see page 14 - page 16.

NexPress on-line
Pay us a visit on our internet home page. You will find us at:
http://www.nexpress.com

Precautions

VI

Warning: Only trained service personnel should perform all aspects of the installation,
relocation, and removal of the glossing unit.

Edition November 11, 2005

Physical Dimensions
1 Physical Dimensions

Important: This section of the Site Specifications includes dimensional information


and room layout illustrations for glossing units with 2 different ranges of serial numbers.
0

For serial numbers 0 -199, continue below.

For serial number 200 and above, go to page 14.

Requirements for glossing units with serial numbers 0 - 199


Room requirements
Room Size: See the room layout illustration below.
Turning Radius: 360 degrees with a minimum 3.0 m (9 ft 10 in.)
The illustration below shows the typical operating configuration and minimum
dimensions of glossing units having a serial number of 0 - 199.

MINI PC
OUTPUT
DELIVERY
TRAY
1.10 m
3 ft 7 1/4 in.
GLOSSING UNIT

1.88 m
6 ft 2 in.

NexGlosser glossing unit Site Specifications

11

Physical Dimensions

The illustration below shows the maximum dimensions of glossing units having a
serial number of 0 -199 with the FEEDER and the ELECTRONIC CONTROL AY extended
to the service position.

0.22 m
8 3/4 in.

ELECTRONIC CONTROL AY

0.77 m
2 ft 6 3/8in.

1.08 m
3 ft 6 3/8 in.

OUTPUT DELIVERY
TRAY
0.46 m
1 ft 6 in.

GLOSSING UNIT
0.41 m
0.86 m
3/4
1
ft
4 1/4 in.
2 ft 9
in.
0.38 m
1 ft 3 in.

0.38 m
1 ft 3 in.

MINI PC

0.60 m
23 1/2 in.
FEEDER

0.64 m
2 ft 1 in.

12

Edition November 11, 2005

Physical Dimensions

Dimensions
Glossing Unit

Width

Depth

Height

Packed*

2.10 m
6 ft 10 3/4in.

1.30 m
4 ft 3 in.

1.20 m
3 ft 11 in.

Unpacked
Without Flat Screen Monitor
& Output Delivery Tray

1.13 m
6 ft 81/2 in.

1.10 m
3 ft 71/4 in.

0.95 m
3 ft 11/4 in.

1.88 m
6 ft 2 in.

1.10 m
3 ft 71/4 in.

0.95 m
3 ft 11/4 in.

With Flat Screen Monitor &


Output Delivery Tray

* Note that a 1.3 m (4 ft 3 in.) long ramp that attaches to the shipping pallet is required
for unloading of the glossing unit.
Service accesses
Front

Back

Sides

Top

1.22 m
4 ft

1.22 m
4 ft

1.22 m
4 ft

0.76 m
2.5 ft

Weights
Weight of
Glossing Unit

Weight of Packing
& Pallet

Total Weight

431 kg
950 lbs

91 kg
200 lbs

522 kg
1150 lbs

NexGlosser glossing unit Site Specifications

13

Physical Dimensions

Requirements for glossing units with serial numbers 200 and above
Room requirements
Room Size: See the room layout illustration below.
Turning Radius: 360 degrees with a minimum 3.0 m (9 ft 10 in.)
The illustration below shows the typical operating configuration and minimum
dimensions of glossing units having a serial number of 200 and above.

COMPUTER
OUTPUT
DELIVERY
TRAY

0.86 m
2 ft 9 3/4 in.

GLOSSING UNIT

1.88 m
6 ft 2 in.

14

Edition November 11, 2005

Physical Dimensions

The illustration below shows the maximum dimensions of glossing units having a
serial number of 200 and above with the FEEDER extended to the service position.

1.13 m
3 ft 8 1/2in.

OUTPUT DELIVERY
TRAY
0.63 m
2 ft 3/4 in.
GLOSSING UNIT

0.86 m
0.41 m
2 ft 9 3/4 in. 1 ft 4 1/4 in.

0.38 m
1 ft 3 in.

0.38 m
1 ft 3 in.

COMPUTER

0.59 m
23 1/2 in.
FEEDER

0.75 m
2 ft 5 1/2 in.

NexGlosser glossing unit Site Specifications

15

Physical Dimensions

Dimensions
Glossing Unit
Packed*

Width

Depth

Height

2.10 m
6 ft 10 3/4in.

1.30 m
4 ft 3 in.

1.19 m
3 ft 11 in.

1.88 m
6 ft 2 in.

0.86 m
2 ft 93/4 in.

1.38 m
4 ft 61/2 in.

Unpacked

* Note that a 1.3 m (4 ft 3 in.) long ramp that attaches to the shipping pallet is required
for unloading of the glossing unit.
Service accesses
Front

Back

Sides

Top

1.22 m
4 ft

1.22 m
4 ft

1.22 m
4 ft

0.91 m
3 ft

Weights

16

Weight of
Glossing Unit

Weight of Packing
& Pallet

Total Weight

431 kg
950 lbs

91 kg
200 lbs

522 kg
1150 lbs

Edition November 11, 2005

Electrical & Environmental Requirements


2 Electrical & Environmental Requirements

Electrical requirements
0

The receptacle must be installed within 61.0 cm (2 feet) of the glossing unit and must
be easily accessible.

30 Amps

208 Volts - use the NEMA L6-30 single receptacle,


For example: Interpower Corporation part number 88031180

230 Volts - use the NA/INTL 30/32 A panel-mount, 25-degree receptacle,


For example: Interpower Corporation part number 84232201

50/60 Hz

Single Phase

Environmental requirements
Ambient temperature
0

Temperature range 17 - 28oC (63 - 82oF)

Humidity range 20 - 70% RH

50 Nl/minute of air at 5.5 bar (79.77 PSI)

Ambient humidity

Air pressure

Incoming compressed air


0

Maximum particle size 0.1

Air supply must be oil and moisture free

Air supply must accommodate a 1/4-inch pipe thread

Air supply line must be within 61.0 cm (2 feet) of the glossing unit

Note: For additional compressed air requirements, refer to the Kodak NexPress 2100 plus

production color press/Kodak NexPress 2500 digital production color press Site
2 digital
Specification - W20N00.

NexGlosser glossing unit Site Specifications

21

Network Specifications
3 Network Specifications

Specifications
Plug
0

RJ-45 jack

10 Base T or 100 Base TX

TCP/IP with available IP address

Type

Protocol

Safety requirements
If cables are routed on the floor, it is necessary to provide measures that will prevent
personnel from tripping on them or damaging them.

NexGlosser glossing unit Site Specifications

31

NexPress Solutions, Inc.


2600 Manitou Road
Rochester, New York 14653
USA
www.nexpress.com
For further information please contact
your local NexPress representative.
2005 Kodak. All rights reserved. Kodak, NexPress,
NexBlanket, NexGlosser, NexPert, NexQ, NexStation and
NexTreme are trademarks of Kodak.

You might also like