L Series: Applications

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ProductSpecification03328

(RevisionB,12/2009)

LSeries
PositionController
Applications
The L-Series Position Controller provides a building block
approach to total engine management. The
microprocessor-based bi-directional actuator design easily
attaches to fuel pumps, mixers, or throttle bodies.

Description
The L-Series Position Controller accepts a position
command and drives the 060 degree output shaft to the
commanded position based on an internal shaft position sensor. The high-efficiency
torque motor delivers 0.34 Nm (0.25 lb-ft) nominally over 60 travel range to operate
fuel or air control devices (see specifications for torque performance over the full
product temperature range).
The L-Series Position
Controller accepts either a
PWM, 05 V, or CAN
command for output
positioning. The command
signals are issued by the
appropriate supervisory engine
management system, and the
L-Series must be set up
properly in software to expect
the correct signal for the
application.
For status purposes, a relay
driver output is available on the
L-Series control which changes state whenever a fault or error condition is
experienced by the controller.
The L-Series provides a direct position output signal in the form of a dc voltage if
required by the system. The throttle position (TPS) output represents full
counterclockwise-to-clockwise rotation of the actuator shaft, and thus gives the
operator an external position indication.
Besides the traditional bracket mount using external linkage, the L-Series control is
available in a variety of mechanical configurations, including integration with diesel
fuel pumps, throttle bodies, and mixers (product spec 03222). The shaft rotation can
be configured for clockwise or counterclockwise rotation for increasing fuel. For
information on Woodward throttle body applications, refer to manual 26249 (ITB and
LC-50).
Woodward offers optional mounting kits for Stanadyne DB-series or Delphi fuel
injection pumps, providing an integrated control solution.
Woodward also offers L-Series actuator versions for Speed Control (manual 26250)
and Process Control (manual 26251), like Air/Fuel Ratio control, applications.
To learn more about the new L-Series actuators, contact Woodward today.
Technical Manual

26237 (standard) or 26289 (w/ CAN)

Low cost, small


package actuator

Extremely fast,
bi-directional,
electronically
positioned in both
directions

All-electric
actuator requires
no drive or
hydraulic supply

60 (2) rotary
output

Single or
redundant position
command signals

Advanced
diagnostics

Tamper-resistant

Configurable
parameters to
tailor to varied
applications

Easy setup and


tuning using PCbased Service
Tool

Optional CANopen
and J1939 CAN
communications

Woodward 03328 p.2

Specifications
Power Supply
Power Consumption
Envelope
Travel
Torque

Mass/Weight
Command Input
Position Feedback Output
Discrete Input
Discrete Output
Programming Port
Positioning Accuracy
Slew Time 10%90%
Roll-off
Operating Temperature
Storage Temperature
EMC

Humidity
Shock
Vibration

Thermal Shock
Fluid Resistance
CSA
CE
Other

12/24 V systems (1032 Vdc) reverse polarity protection


32 W maximum
2.618 x 2.618 x 2.540 (66.50 x 66.50 x 64.52 mm)
60 2 degrees
Nominal: 0.34 Nm (0.25 lb-ft) at 25 C
Maximum Transient (at 105 C): 0.20 Nm (0.15 lb-ft)
Minimum Continuous (at 105 C): 0.14 Nm (0.10 lb-ft)
425 g (15 oz)
PWM (532 V, 3001500 Hz), CAN, or Analog (05 V)
0.75 V (full ccw) to 4.25 V (full cw)
Optional Run Enable
Low side output driver; software configurable
Programmable with Windows GUI software (9927-1222) and harness (8923-1061)
Performance
2% at 25 C
4% (analog), 3.6% (PWM) , 3% (CAN)over temp. range
33 ms, 1% overshoot, 10 ms settling time
32 Hz (6 dB at 0.5% Input), 8 Hz (3 dB at 2% input)
Environment
40 to +105 C (40 to +221 F)
40 to +125 C (40 to +257 F)
EN61000-6-2: Immunity for Industrial Environments
EN61000-6-4: Emissions for Industrial Environments
SAE J1113-21: Radiated Immunity (100 V/m)
SAE J1113-11: Conducted Transient Immunity
Pulse 5b, Suppressed Load Dump (45 V)
US MIL-STD 810E, Method 507.3, Procedure III
MS1-40G 11ms sawtooth
Random: 0.3 G/Hz, 102000 Hz (22.1 Grms) 3 h/axis
Sine: 5 G 2.5 mm peak-to-peak, 52000 Hz, 3 h/axis,
90 min dwells, 1 octave/min
SAE J1455, Paragraph 4.1.3.2
IP56 per EN60529
Compliance
Class I, Division 2, Groups A, B, C, D T3C
Compliant with EMC Directive 89/336/EEC
Compliant as a component with Machinery Directive 98/37/EC

For more information contact:


PO Box 1519, Fort Collins CO, USA 80522-1519
1000 East Drake Road, Fort Collins CO 80525
Tel.: +1 (970) 482-5811 Fax: +1 (970) 498-3058
www.woodward.com
Distributors & Service
Woodward has an international network of distributors and service facilities.
For your nearest representative, call the Fort Collins plant or see the
Worldwide Directory on our website.
This document is distributed for informational purposes only. It is not to be construed as
creating or becoming part of any Woodward contractual or warranty obligation unless
expressly stated in a written sales contract.

Copyright Woodward 20032009, All Rights Reserved

You might also like