Ug 25 Plus Governor

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

ProductSpecification

03339(Rev.G)

UG25
Governor

Suitable for
gasoline, gaseous,
and diesel fueled
engines

Convenient front
panel adjustments

Speed setting with


standard 4 mA to
20 mA signal or
using raise/lower
commands

Easy setup and


tuning using
PC-based Service
Tool

Discrete output
driver for status
indication

Isochronous or
droop control

Drop-in
replacement for
UG-8 and 3161
governors

Adjustable droop permits load division and balancing among parallel operated prime
movers. Droop can be set with a knob on the front panel between 010. The load
limiter knob allows you to limit the governor output manually.

The UG-25+ uses a 1034 kPa (150 psi) internal operating pressure with an internal
oil pump driven from the governor's drive shaft, available in either a keyed or
serrated configuration. Oil pressure is maintained by a relief valve system with a
drain to an internal oil sump.

34 J (25 ft-lb) &


41 J (31 ft-lb)
versions available

Available with
either a keyed or
serrated drive
shaft

Compliant with
applicable CE
DirectivesEMC,
Pressure
Equipment,
Machinery

Certified for use in


marine
applications

Description
The Woodward UG-25+ governor is a
microprocessor-controlled, mechanicalhydraulic amplified, governor for controlling
diesel, gas, and dual fuel engines, and steam
turbines.
Enhanced control capabilities, such as start
fuel and boost limiting schemes, are an
integral part of the UG-25+ governor. The
additional transient fuel limiting (jump-rate)
improves the engine load acceptance and
reduces transient emissions significantly.
This fast-acting, high-work-output governor
has no need for any auxiliary devices such as
a start booster or oil cooler. Two work output
versions are available.
The UG-25+ offers speed control with
software-selectable speed set points,
dynamics, fuel limiting, and start behavior. All
it takes is a PC to adjust and download
configuration data.
Front panel and external speed settings make
synchronization and load sharing easy for
generator applications. A 4 mA to 20 mA
speed setting is available for variable speed applications.

Control features:
State-of-the-art speed sensing and control algorithms
Enhanced PID dynamics
Configurable speed settings and adjustment rates
Multiple fuel limiting algorithms, such as jump-rate, boost pressure, and start fuel
limiting
Comprehensive diagnostics for easy troubleshooting
The UG-25+ is a drop-in replacement for UG-8 and 3161 governors and combines all
the advantages of a traditional mechanical governor with the state-of-the-art control
algorithms for optimal engine operation.

Woodward 03339 p.2

Specifications
Governor
Power Supply
Power Consumption
Torque/Work Output (minimum):
Standard Version
(0.625 inch diameter terminal shaft)
Increased Output Version
(0.75 inch diameter terminal shaft)
Max. Continuous Speed
Hysteresis
Temperature Drift
Linearity
Ramp-up Rate
Steady State Speed Band
Weight
Customer Connections
Governor Drive / Hydraulic System
Input Shaft Options
Output
Terminal Shaft Options
Drive Power Requirement
Internal Hydraulic Pressure
Oil
Drive Speed

Drive Rotation

(18 to 32) V (dc), dual inputs


Reverse polarity protection, 32 W max

45.4 Nm (33.5 lb-ft) torque; 32.9 J (24.3 ft-lb) of work over 42 degrees
55.5 Nm (40.9 lb-ft) torque; 40.2 J (29.6 ft-lb) of work over 42 degrees
1700 rpm (gov. shaft) max (small pump);
1200 rpm (gov. shaft) max (large pump)
1.0 % or less (measured over full terminal shaft travel)
1.0 % of full terminal shaft travel between 27 C and 77 C (80 F and
170 F)
2.5 % or less (measured over full terminal shaft travel)
Configurable from 0.2 to 200 rpm/s (gov. shaft)
0.25% of rated speed (under normal operating conditions)
28 kg (62 lb), dry weight
Terminal blocks located inside front access plate
0.625 keyed drive shaft with 0.625-18 threads or 0.625-36 serrated
42.2 0.6 degrees rotary
0.625-36 serration (standard), 0.750-36 serration (increased output version)
335 W (0.45 hp) max.
1034 kPa (150 psi)
Self-contained sump (2.1 L / 2.2 quart capacity). See Woodward Manual
25071, Oils for Hydraulic Controls, for oil recommendations.
Available with either high or low speed pump
High-speed pump: 500 rpm to 1700 rpm (gov. shaft)
Low Speed pump: 350 rpm to 1200 rpm (gov. shaft)
Pump can be configured to operate in CW or CCW direction

Functions
Function Options

Programming Port
I/O

Front Panel Functions

Front Panel Indications

Start Fuel Limiter; Adjustable Max Fuel Stop; Jump and Rate Limiter;
Position-based Gain curve; Manifold Air Pressure Biased Fuel Limiter,
Analog set-point rate limit; separate Raise and Lower Rates; Start Gain
Programmable with Windows GUI software and harness
4 mA to 20 mA analog speed setting; Analog Speed Set-point selector
Raise, Lower, and Stop discrete inputs
Analog Speed Set Enable discrete input
4 mA to 20 mA boost fuel limiter input; Boost Input selector
Unit Healthy discrete out
Raise and Lower speed set-point commands
Stop command; Droop adjustment; Stability adjustment, Fuel-Limit
adjustment
Unit Healthy status indication, Speed Set-point mode indications
(Raise/Lower or Analog)

Woodward 03339 p.3

UG-25+ Outline Drawing


(Do Not Use for Construction)

Drive Shaft Options

Woodward
d 03339 p.4

Speecification
ns(contin
nued)
Environment
A
Ambient
Operrating Temperature
Governor Case Temperature
Sto
orage Temperature
EMC
Humidity
Shock
S
V
Vibration
Valid
dation

Thermal Shock
S
Ingress Protection

0 C to 55 C (32 F to 131 F
F)
100
0 C (212 F) maximum
40
0 C to +85 C
C (40 F to +185
+
F), limited by electro
onics
EN
N61000-6-2: Im
mmunity for In
ndustrial Enviironments
EN
N61000-6-4: Emissions
E
for Industrial Envvironments
US
S MIL-STD 810E, Method 507.3,
5
Proced
dure III
MS
S1-40G 11 mss saw tooth
Pow
wer Spectral Density (PSD
D) must not exxceed the levvel or frequency as
sho
own in the curve while the governor is running on a loaded engine
e, as
me
easured at govvernor base.

SA
AE J1455, Parragraph 4.1.3.2
IP4
45 for entire unit.
u
IP56 for User
U
Interface
e per EN6052
29 and only if proper
cab
ble glands are
e used as desscribed in the technical ma
anual.

Regu
ulatory Comp
pliance
European Co
ompliance fo
or CE Markin
ng:
EMC Dire
ective:
200
04/108/EC
Other Europ
pean Complia
ance:
(Compliance with the follo
owing Europea
an Directives or standardss does not qua
alify this product for application of
the CE Markiing)
M
Machinery
Dire
ective:
Compliant as pa
artly complete
ed machinery per 2006/42//EC
Pressure Eq
quipment Dire
ective:
Compliant as S
SEP per Articcle 3.3 to 97/2
23/EC
Marine Compliance:
Models are available
a
that are suitable for
f marine app
plications. Co
ontact your sa
ales represen
ntative for mo
ore
information.
Technica
al Manual

26579

For more informa


ation contact:
PO Box 1519, Fort Collin
ns CO, USA 805
522-1519
E
Drake Road, Fort Collins CO
O 80525
1000 East
Tel.: +1 (9
970) 482-5811 Fax: +1 (970) 498-3058
www.wood
dward.com
Distributorrs & Service
Woodw
ward has an inte
ernational networrk of distributors and service facilities.
For yo
our nearest repre
esentative, call th
he Fort Collins plant or see the
Worldw
wide Directory on our website.
ocument is distributted for informationa
al purposes only. It is not to be constrrued as
This do
creating or becoming partt of any Woodward contractual or warrranty obligation un
nless
expressly stated in a writtten sales contract.

Wo
oodward 2006, All Rights Rese
erved

2012/5
5/Colorado

You might also like