MultiGAMINATOR42dop1 Eng
MultiGAMINATOR42dop1 Eng
MultiGAMINATOR42dop1 Eng
20 July 2010
OWNER Manual
Multi GAMINATOR block type
The author of this guidance spares large attention drafting and association of technical information, taking into account
advantages of progressive supervisory mechanisms. Nevertheless, it is impossible fully to eliminate possible errors. Therefore a
producer carries no responsibility, including legal, for any consequences which can arise up from incorrect positions of this
guidance. An author will thank for any error diagnostics.
Introduction
Multi GAMINATOR block type alternative to the original programs of
Gaminator on the platform of Cool Fire I. In this playing program the
independent choice of version of set of slots of Gaminator is possible
from I for the XXX versions, and also forming of the set is possible
from the games resulted below. This product has similar graphic arts
with the programs of Cool Fire I, but is not a copy or modification of
multigame of Novomatic.
Games of multigame Multi GAMINATOR block type:
Always Hot
Bananas Go Bahamas
Beatle Mania
Book Of Ra
Columbus
Dolphins Pearl
Hot T arget
Just Jewels
Lucky Ladys Charm
Magic Money
Marco Polo
Olivers Bar
Pharaohs Gold II
Queen Of Hearts
Riches Of India
Roller Coaster
Sharky
Sizzling Hot
The Money Game
Ultra Hot
Unicorn Magic
Venetian Carnival
The mathematical algorithm of work of the program is similar with
original Gaminator, only that goes out on the set percent for less of
games.
User's guide
written by http://www.simtech.com.ua
Installation.
For the feed of pay the power module is required with 24pin ATX Power
Connector, by power more 100Vt. At the turned off feed of the power
module will connect in turn: feed-in sockets from the power module:
24pin ATX, 4pin ATKH 12v. We connect the cord of sound and interface
cord of management comptroller . On the pay of comptroller connect a
feed from the power the socket of 4pin module +5V GND GND +12V.
We connect the lower monitor of vehicle in the socket of VGA, in the
socket of DVI overhead (take into account that an overhead monitor
will work only with a digital signal, the type of cable and monitor
must be expected under DVI-D!) Connect wires of keyboard of automat to
the regional socket of JAMMA 72pin. Pin out table is resulted in a
table in addition.
User's guide
written by http://www.simtech.com.ua
Active buttons:
HOLD 4 - Down
HOLD 5 - Enter
Active buttons:
HOLD 1 - Back
HOLD 4 - Down
HOLD 5 Enter
Active buttons:
HOLD 1 - Back
HOLD 3 - 10 CREDITS
HOLD 4 - 100 CREDITS
HOLD 5 - 1000 CREDITS
4). Press the necessary keys for setting of the required value of credit.
5). The chosen credit will be set automatically on a credit meter.
6). Briefly turn the key of operator.
7). An automat automatically will be commuted in the playing mode.
The function of REMOTE IN can be used only, if it is included in an administrator
menu.
User's guide
written by http://www.simtech.com.ua
Active buttons:
HOLD 4 - Down
HOLD 5 - Enter
Active buttons:
HOLD
HOLD
HOLD
HOLD
1
2
4
5
Back
Up
Down
Enter
Active buttons:
HOLD 1 - Back
HOLD 5 - HandPay
4). Press the necessary keys for a removal and payment of the value of credit
required by hand.
5). Payment by hand automatically will be registered on the meter of payments.
6). Briefly turn the key of operator.
7). An automat automatically will be commuted in the playing mode.
User's guide
written by http://www.simtech.com.ua
Managing menu
For included in the complete administrator menu of management of owner briefly turn
the key of operator, open a door FRONT DOOR SERVICE (lock the contact of 16a on
earth). After the eigentone of the unclosed door once again turn the key of operator.
Will appear AUDIT MENU with additional points MACHINE SETUP and ADMINISTRATION.
ATTENDANT> REMOTE IN
REMOTE IN: Press the necessary keys for setting of the required value of credit.
CURRENT CREDIT: Shows the size of current credit.
The proper cost and set credit of every payment transaction is shown.
HANDPAY CREDIT: Press the proper keys for the upcast of present sum.
CURRENT HANDPAY: Shows the size of current credit.
The proper cost and set credit of every payment transaction is shown.
User's guide
written by http://www.simtech.com.ua
TOTAL IN: Lump sum of all entered bank-papers and added credits through a
function REMOTE IN.
BILL IN: Lump sum of the accepted bank-papers.
REMOTE IN: Lump sum of all added credits through a function REMOTE IN.
HANDPAY.
The proper cost and set credit of every payment transaction is shown.
User's guide
written by http://www.simtech.com.ua
User's guide
written by http://www.simtech.com.ua
User's guide
written by http://www.simtech.com.ua
CHANGE PASSWORD: For the change of standard password enter in this menu.
Enter a new password, will confirm Enter. You will memorize the entered
password, renewal of the lost password is possible only in a service-center!
User's guide
written by http://www.simtech.com.ua
User's guide
written by http://www.simtech.com.ua
12
Setting of conclusions
Contact
Setting
1
2
3
4
5
6
7
8
9
10
11
12
Setting of conclusions
# of pin
1
2
3
4
5
6
7
8
9
User's guide
+12 V
M.RES
+12 V (INTERFACE)
GND
LED+
NC
GND
TXD
RXD
NC
LEDNC
Name
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI
Type of signal
IN
OUT
IN
OUT
IN
OUT
IN
IN
Data type
Data carrier detect
Transmit data
Receive data
Data terminal ready
Ground
Data set ready
Request to send
Clear to send
Ring indicator
written by http://www.simtech.com.ua
9
RRI#1
RRTS#1
GND
TTXD1
DDCD#1
User's guide
written by http://www.simtech.com.ua
Below on a picture chart of connecting of interface cable and feed to the socket.
ATTENTION! I will eat away bill acceptor represented from the side of wires.
Black
White
Slant
1
Interface Cable
GND
Blue
+5 V
Red
+12 V
ATTENTION! On some models of interface cable a feed is required +12 volt in place of +5A.
GND
TXD2
RXD2
Program
Reset
VCC
RXD1
TXD1
Blue
Red
Black
White
Note: For any connecting of other bill acceptor on protocol it is possible to use the
that interface cable of A7. For this purpose a socket retires for ICT A7, a socket
for a feed and reducer is added for the necessity of bill acceptor. Connecting of
bill acceptor is possible on the impulse of see 72-pin connector.
In a menu the necessary tuning get out for bill acceptor. For the maintainance of
information it is necessary to carry out a restart by the shutdown of feed.
User's guide
written by http://www.simtech.com.ua
Addition 1
JAMMA 72pin connector
pin
1a
2a
3a
4a
5a
6a
7a
8a
9a
10a
11a
12a
13a
14a
15a
16a
17a
18a
19a
20a
21a
22a
23a
24a
25a
26a
27a
28a
29a
30a
31a
32a
33a
34a
35a
36a
Part Side
SPEAKER
HOLD1 SW
HOLD 2 SW
HOLD 3 SW
HOLD 4 SW
HOLD 5 SW
START SW
BET ONE SW
SELECT GAME SW
AUTO START SW
MAXBET SW
INFO SW
FRONT DOOR (SERVICE) SW
KEY ATTENDANT SW
COLLECT SW (PAYOUT BUTTON)
REMOTE&BILLS COUNTER
GAMES COUNTER
HANDPAY COUNTER
HOLD 1 LAMP
HOLD 2 LAMP
HOLD 3 LAMP
HOLD 4 LAMP
HOLD 5 LAMP
START LAMP
GND
Solder Side
1b
2b
3b
4b
5b
6b
7b
8b
9b
10b
11b
12b
13b
14b
15b
16b
17b
18b
19b
20b
21b
22b
23b
24b
25b
26b
27b
28b
29b
30b
31b
32b
33b
34b
35b
36b
GND
BILL ACCEPTOR (PULSE)
User's guide