POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
CLIENT : M/s. INGENIO RISARALDA S. A., COLOMBIA
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
FROM
NOTE :-
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
BOILER MCC-01
1
BOILER MCC-01
P-M319
3C X 2.5 Cu.
102
102
1555.25.1.17
CPI-18
BOILER MCC-01
C-M319
5C X 1.5 Cu.
102
102
1555.25.1.17
CPI-17
10
BOILER MCC-01
C-M319-2
7C X 1.5 Cu.
102
102
1555.25.1.17
CPI-17
14
BOILER MCC-01
P-M320
3C X 2.5 Cu.
117
117
1555.25.1.17
CPI-18
BOILER MCC-01
C-M320
5C X 1.5 Cu.
117
117
1555.25.1.17
CPI-17
10
BOILER MCC-01
C-M320-2
7C X 1.5 Cu.
117
117
1555.25.1.17
CPI-17
14
BOILER MCC-01
P-M321
3C X 2.5 Cu.
104
104
1555.25.1.17
CPI-18
BOILER MCC-01
C-M321
5C X 1.5 Cu.
104
104
1555.25.1.17
CPI-17
10
BOILER MCC-01
C-M321-2
7C X 1.5 Cu.
104
104
1555.25.1.17
CPI-17
14
10
BOILER MCC-01
P-M322
3C X 2.5 Cu.
119
119
1555.25.1.17
CPI-18
11
BOILER MCC-01
C-M322
5C X 1.5 Cu.
119
119
1555.25.1.17
CPI-17
10
12
BOILER MCC-01
C-M322-2
7C X 1.5 Cu.
119
119
1555.25.1.17
CPI-17
14
13
BOILER MCC-01
P-M323
3C X 2.5 Cu.
106
106
1555.25.1.17
CPI-18
14
BOILER MCC-01
C-M323
5C X 1.5 Cu.
106
106
1555.25.1.17
CPI-17
10
15
BOILER MCC-01
C-M323-2
7C X 1.5 Cu.
106
106
1555.25.1.17
CPI-17
14
16
BOILER MCC-01
P-M324
3C X 2.5 Cu.
121
121
1555.25.1.17
CPI-18
17
BOILER MCC-01
C-M324
5C X 1.5 Cu.
121
121
1555.25.1.17
CPI-17
10
18
BOILER MCC-01
C-M324-2
7C X 1.5 Cu.
121
121
1555.25.1.17
CPI-17
14
Page 1 of 34
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
CLIENT : M/s. INGENIO RISARALDA S. A., COLOMBIA
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
NOTE :-
FROM
19
BOILER MCC-01
3C X 2.5 Cu.
100
100
1555.25.1.17
CPI-18
20
BOILER MCC-01
5C X 1.5 Cu.
100
100
1555.25.1.17
CPI-17
10
21
BOILER MCC-01
3C X 2.5 Cu.
102
102
1555.25.1.17
CPI-18
22
BOILER MCC-01
5C X 1.5 Cu.
102
102
1555.25.1.17
CPI-17
10
23
BOILER MCC-01
3C X 2.5 Cu.
104
104
1555.25.1.17
CPI-18
24
BOILER MCC-01
5C X 1.5 Cu.
104
104
1555.25.1.17
CPI-17
10
25
BOILER MCC-01
3C X 2.5 Cu.
116
116
1555.25.1.17
CPI-18
26
BOILER MCC-01
C-M430
5C X 1.5 Cu.
116
116
1555.25.1.17
CPI-17
10
27
BOILER MCC-01
3C X 2.5 Cu.
110
110
1555.25.1.17
CPI-18
28
BOILER MCC-01
C-M431
5C X 1.5 Cu.
110
110
1555.25.1.17
CPI-17
10
29
BOILER MCC-01
P1-M439
3C X 70 Cu.
127
127
1555.40.1.33
CUS-358
30
P2-M439
3C X 70 Cu.
127
127
1555.40.1.33
CUS-358
31
C-M439
127
127
1555.32.1.25
CPI-17
20
32
2C X 1.5 Cu.
127
127
1555.25.1.17
CPI-17
33
2C X 1.5 Cu.Sc.
127
127
1555.25.1.17
CPI-17
34
BOILER MCC-01
3C X 35 Cu.
82
82
1555.32.1.25
CUS-356
35
BOILER MCC-01
C-M451
5C X 1.5 Cu.
82
82
1555.25.1.17
CPI-17
10
36
BOILER MCC-01
P-M451-2
2C X 1.5 Cu.
82
82
CPI-17
TO
C-439-2
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
Page 2 of 34
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
SL.
NO.
1555.25.1.17
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
CUS-543
FROM
37
BOILER MCC-01
38
MOV DB - 01
39
MOV DB - 01
40
NOTE :-
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
DB-01
4C X 4 Cu.
100
100
P-M301
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
P-M302
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
MOV DB - 01
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
41
MOV DB - 01
P-M304
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
42
MOV DB - 01
P-M309
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
43
MOV DB - 01
P-M310
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
44
BOILER MCC-01
MOV DB -02
DB-02
4C X 2.5 Cu.
100
100
CPI-18
45
MOV DB -02
P-M313
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
46
MOV DB -02
P-M314
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
47
MOV DB -02
P-M315
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
48
MOV DB -02
P-M316
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
49
MOV DB -02
P-M317
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
50
MOV DB -02
P-M318
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
MOV DB - 01
ISO. VALVE AT UPSTREAM OF
100% FEED CONTROL VALVE
(BB308)
ISO. VALVE AT UPSTREAM OF
100% FEED CONTROL BYPASS
(BB3100)
Page 3 of 34
1555.25.1.17
1555.25.1.17
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
CLIENT : M/s. INGENIO RISARALDA S. A., COLOMBIA
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
NOTE :-
FROM
51
BOILER MCC-01
P-M501
3C X 2.5 Cu.
112
112
1555.25.1.17
CPI-18
52
BOILER MCC-01
C-M501
5C X 1.5 Cu.
112
112
1555.25.1.17
CPI-17
10
53
BOILER MCC-01
P-M502
3C X 2.5 Cu.
118
118
1555.25.1.17
CPI-18
54
BOILER MCC-01
5C X 1.5 Cu.
118
118
1555.25.1.17
CPI-17
10
55
BOILER MCC-01
P-M503
3C X 2.5 Cu.
109
109
1555.25.1.17
CPI-18
56
BOILER MCC-01
C-M503
5C X 1.5 Cu.
109
109
1555.25.1.17
CPI-17
10
57
BOILER MCC-01
P-M504
3C X 2.5 Cu.
110
110
1555.25.1.17
CPI-18
58
BOILER MCC-01
C-M504
5C X 1.5 Cu.
110
110
1555.25.1.17
CPI-17
10
59
BOILER MCC-01
P-M505
3C X 2.5 Cu.
115
115
1555.25.1.17
CPI-18
60
BOILER MCC-01
C-M505
5C X 1.5 Cu.
115
115
1555.25.1.17
CPI-17
10
61
BOILER MCC-01
P-M506
3C X 2.5 Cu.
116
116
1555.25.1.17
CPI-18
62
BOILER MCC-01
C-M506
5C X 1.5 Cu.
116
116
1555.25.1.17
CPI-17
10
63
BOILER MCC-01
MOV DB - 03
DB-03
4C X 4 Cu.
100
100
CUS-543
64
MOV DB - 03
P-M507
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
65
MOV DB - 03
P-M508
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
66
MOV DB - 03
P-M510
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
67
MOV DB - 03
P-M509
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
Page 4 of 34
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
SL.
NO.
1555.25.1.17
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
CLIENT : M/s. INGENIO RISARALDA S. A., COLOMBIA
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
NOTE :-
FROM
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
68
MOV DB - 03
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
69
MOV DB - 03
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
70
BOILER MCC-01
P-M919
3C X 2.5 Cu.
85
85
1555.25.1.17
CPI-18
71
BOILER MCC-01
C-M919
5C X 1.5 Cu.
85
85
1555.25.1.17
CPI-17
10
72
BOILER MCC-01
UPS-1
3C X 4 Cu.
40
40
1555.25.1.17
CUS-543
73
BOILER MCC-01
WELDING SOCKET
4C X 16 Cu.
60
60
1555.32.1.25
CUS-549
BOILER MCC-02
74
BOILER MCC-02
3C X 2.5 Cu.
94
94
1555.25.1.17
CPI-18
75
BOILER MCC-02
5C X 1.5 Cu.
94
94
1555.25.1.17
CPI-17
10
76
BOILER MCC-02
3C X 2.5 Cu.
98
98
1555.25.1.17
CPI-18
77
BOILER MCC-02
C-M414
5C X 1.5 Cu.
98
98
1555.25.1.17
CPI-17
10
78
BOILER MCC-02
P-M421
3C X 2.5 Cu.
82
82
1555.25.1.17
CPI-18
79
BOILER MCC-02
C-M421
5C X 1.5 Cu.
82
82
1555.25.1.17
CPI-17
10
80
BOILER MCC-02
P-M422
3C X 2.5 Cu.
86
86
1555.25.1.17
CPI-18
81
BOILER MCC-02
C-M422
5C X 1.5 Cu.
86
86
1555.25.1.17
CPI-17
10
82
BOILER MCC-02
P-M423
3C X 2.5 Cu.
90
90
1555.25.1.17
CPI-18
83
BOILER MCC-02
C-M423
5C X 1.5 Cu.
90
90
1555.25.1.17
CPI-17
10
84
BOILER MCC-02
P-M448
3C X 2.5 Cu.
82
82
1555.25.1.17
CPI-18
Page 5 of 34
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
CLIENT : M/s. INGENIO RISARALDA S. A., COLOMBIA
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
NOTE :-
FROM
85
BOILER MCC-02
C-M448
5C X 1.5 Cu.
82
82
1555.25.1.17
CPI-17
10
86
BOILER MCC-02
P-M449
3C X 2.5 Cu.
85
85
1555.25.1.17
CPI-18
87
BOILER MCC-02
C-M449
5C X 1.5 Cu.
85
85
1555.25.1.17
CPI-17
10
88
BOILER MCC-02
P-M450
3C X 2.5 Cu.
88
88
1555.25.1.17
CPI-18
89
BOILER MCC-02
C-M450
5C X 1.5 Cu.
88
88
1555.25.1.17
CPI-17
10
90
BOILER MCC-02
P-M916
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
91
BOILER MCC-02
C-M916
5C X 1.5 Cu.
50
50
1555.25.1.17
CPI-17
10
92
BOILER MCC-02
3C X 2.5 Cu.
52
52
1555.25.1.17
CPI-18
93
BOILER MCC-02
5C X 1.5 Cu.
52
52
1555.25.1.17
CPI-17
10
94
BOILER MCC-02
P-FF-VFD
3C X 25 Cu.
40
40
CUS-551
95
P-M407
3C X 2.5 Cu.
102
102
CPI-18
96
C-M407-01
102
102
1555.32.1.25
CPI-17
20
97
C-M407-02
2C X 1.5 Cu.Sc.
102
102
1555.25.1.17
CPI-17
98
P-M408
3C X 2.5 Cu.
104
104
CPI-18
99
C-M408-01
104
104
1555.32.1.25
CPI-17
20
100
C-M408-02
2C X 1.5 Cu.Sc.
104
104
1555.25.1.17
CPI-17
101
P-M409
3C X 2.5 Cu.
106
106
CPI-18
102
C-M409-01
106
106
CPI-17
20
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
Page 6 of 34
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
SL.
NO.
1555.32.1.25
1555.25.1.17
1555.25.1.17
1555.25.1.17
1555.32.1.25
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
CPI-17
CPI-18
NOTE :-
FROM
103
C-M409-02
2C X 1.5 Cu.Sc.
106
106
104
P-M410
3C X 2.5 Cu.
108
108
105
C-M410-01
108
108
1555.32.1.25
CPI-17
20
106
C-M410-02
2C X 1.5 Cu.Sc.
108
108
1555.25.1.17
CPI-17
107
P-M411
3C X 2.5 Cu.
110
110
CPI-18
108
C-M411-01
110
110
1555.32.1.25
CPI-17
20
109
C-M411-02
2C X 1.5 Cu.Sc.
110
110
1555.25.1.17
CPI-17
110
P-M412
3C X 2.5 Cu.
112
112
CPI-18
111
C-M412-01
112
112
1555.32.1.25
CPI-17
20
112
C-M412-02
2C X 1.5 Cu.Sc.
112
112
1555.25.1.17
CPI-17
113
P-M419
3C X 2.5 Cu.
91
91
CPI-18
114
C-M419-01
91
91
1555.32.1.25
CPI-17
20
115
C-M419-02
2C X 1.5 Cu.Sc.
91
91
1555.25.1.17
CPI-17
116
P-M420
3C X 2.5 Cu.
93
93
CPI-18
117
C-M420-01
93
93
1555.32.1.25
CPI-17
20
118
C-M420-02
2C X 1.5 Cu.Sc.
93
93
1555.25.1.17
CPI-17
119
BOILER MCC-02
3C X 2.5 Cu.
76
76
1555.25.1.17
CPI-18
120
BOILER MCC-02
5C X 1.5 Cu.
76
76
1555.25.1.17
CPI-17
10
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
Page 7 of 34
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
SL.
NO.
1555.25.1.17
1555.25.1.17
1555.25.1.17
1555.25.1.17
1555.25.1.17
1555.25.1.17
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
CLIENT : M/s. INGENIO RISARALDA S. A., COLOMBIA
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
FROM
121
BOILER MCC-02
122
BOILER MCC-02
123
BOILER MCC-02
NOTE :-
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
3C X 2.5 Cu.
78
78
1555.25.1.17
CPI-18
5C X 1.5 Cu.
78
78
1555.25.1.17
CPI-17
10
3C X 2.5 Cu.
80
80
1555.25.1.17
CPI-18
5C X 1.5 Cu.
80
80
1555.25.1.17
CPI-17
10
124
BOILER MCC-02
125
BOILER MCC-02
3C X 2.5 Cu.
82
82
1555.25.1.17
CPI-18
126
BOILER MCC-02
5C X 1.5 Cu.
82
82
1555.25.1.17
CPI-17
10
127
BOILER MCC-02
MOV DB - 04
4C X 2.5 Cu.
100
100
CPI-18
128
MOV DB - 04
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
129
MOV DB - 04
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
130
MOV DB - 04
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
131
MOV DB - 04
3C X 2.5 Cu.
50
50
1555.25.1.17
CPI-18
132
BOILER MCC-02
P1-M441
3C X 70 Cu.
123
123
1555.40.1.33
CUS-358
P2-M441
3C X 70 Cu.
123
123
1555.40.1.33
CUS-358
C-M441
123
123
1555.32.1.25
CPI-17
20
133
134
DB-04
1555.25.1.17
135
P-M441-2
2C X 1.5 Cu.
123
123
1555.25.1.17
CPI-17
136
C-M441-2
2C X 1.5 Cu.Sc.
123
123
1555.25.1.17
CPI-17
137
BOILER MCC-02
P-M401
3C X 2.5 Cu.
92
92
1555.25.1.17
CPI-18
138
BOILER MCC-02
P-M402
3C X 2.5 Cu.
95
95
1555.25.1.17
CPI-18
139
BOILER MCC-02
P-M403
3C X 2.5 Cu.
98
98
1555.25.1.17
CPI-18
Page 8 of 34
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
CLIENT : M/s. INGENIO RISARALDA S. A., COLOMBIA
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
NOTE :-
FROM
140
BOILER MCC-02
P-M404
3C X 2.5 Cu.
100
100
1555.25.1.17
CPI-18
141
BOILER MCC-02
P-M405
3C X 2.5 Cu.
102
102
1555.25.1.17
CPI-18
142
BOILER MCC-02
P-M406
3C X 2.5 Cu.
104
104
1555.25.1.17
CPI-18
143
BOILER MCC-02
P-M920
3C X 2.5 Cu.
85
85
1555.25.1.17
CPI-18
144
BOILER MCC-02
C-M920
5C X 1.5 Cu.
85
85
1555.25.1.17
CPI-17
10
145
BOILER MCC-02
P-M325
3C X 2.5 Cu.
112
112
1555.25.1.17
CPI-18
146
BOILER MCC-02
C-M325
5C X 1.5 Cu.
112
112
1555.25.1.17
CPI-17
10
147
BOILER MCC-02
C-M325-2
7C X 1.5 Cu.
112
112
1555.25.1.17
CPI-17
14
148
BOILER MCC-02
P-M326
3C X 2.5 Cu.
95
95
1555.25.1.17
CPI-18
149
BOILER MCC-02
C-M326
5C X 1.5 Cu.
95
95
1555.25.1.17
CPI-17
10
150
BOILER MCC-02
C-M326-2
7C X 1.5 Cu.
95
95
1555.25.1.17
CPI-17
14
151
BOILER MCC-02
P-M327
3C X 2.5 Cu.
97
97
1555.25.1.17
CPI-18
152
BOILER MCC-02
C-M327
5C X 1.5 Cu.
97
97
1555.25.1.17
CPI-17
10
153
BOILER MCC-02
C-M327-2
7C X 1.5 Cu.
97
97
1555.25.1.17
CPI-17
14
154
BOILER MCC-02
WELDING SOCKET
4C X 16 Cu.
100
100
1555.32.1.25
CUS-549
155
BOILER MCC-02
UPS-2
3C X 4 Cu.
50
50
1555.25.1.17
CUS-543
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
Page 9 of 34
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
SL.
NO.
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
CLIENT : M/s. INGENIO RISARALDA S. A., COLOMBIA
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
FROM
NOTE :-
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
P-M424
3C X 2.5 Cu.
88
88
1555.25.1.17
CPI-18
157
C-M424
5C X 1.5 Cu.
88
88
1555.25.1.17
CPI-17
10
158
P-M425
3C X 2.5 Cu.
90
90
1555.25.1.17
CPI-18
159
C-M425
5C X 1.5 Cu.
90
90
1555.25.1.17
CPI-17
10
160
P-M426
3C X 2.5 Cu.
92
92
1555.25.1.17
CPI-18
161
C-M426
5C X 1.5 Cu.
92
92
1555.25.1.17
CPI-17
10
162
P-M901
3C X 2.5 Cu.
82
82
1555.25.1.17
CPI-18
163
C-M901
5C X 1.5 Cu.
82
82
1555.25.1.17
CPI-17
10
P-M902
3C X 2.5 Cu.
93
93
1555.25.1.17
CPI-18
164
SCREW CONVEYOR AT
ECONOMISER HOPPER MOTOR
165
SCREW CONVEYOR AT
ECONOMISER HOPPER LPBS
C-M902
5C X 1.5 Cu.
93
93
1555.25.1.17
CPI-17
10
166
P-M903
3C X 2.5 Cu.
103
103
1555.25.1.17
CPI-18
167
C-M903
5C X 1.5 Cu.
103
103
1555.25.1.17
CPI-17
10
168
P-M904
3C X 2.5 Cu.
42
42
1555.25.1.17
CPI-18
169
C-M904
5C X 1.5 Cu.
42
42
1555.25.1.17
CPI-17
10
Page 10 of 34
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
CLIENT : M/s. INGENIO RISARALDA S. A., COLOMBIA
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
FROM
NOTE :-
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
170
P-M905
3C X 2.5 Cu.
40
40
1555.25.1.17
CPI-18
171
C-M905
5C X 1.5 Cu.
40
40
1555.25.1.17
CPI-17
10
172
P-M906
3C X 2.5 Cu.
99
99
1555.25.1.17
CPI-18
173
C-M906
5C X 1.5 Cu.
99
99
1555.25.1.17
CPI-17
10
174
P-M907
3C X 2.5 Cu.
216
216
1555.25.1.17
CPI-18
175
C-M907
5C X 1.5 Cu.
216
216
1555.25.1.17
CPI-17
10
176
P-M908
3C X 2.5 Cu.
34
34
1555.25.1.17
CPI-18
177
C-M908
5C X 1.5 Cu.
34
34
1555.25.1.17
CPI-17
10
178
P-M909
3C X 2.5 Cu.
89
89
1555.25.1.17
CPI-18
179
C-M909
5C X 1.5 Cu.
89
89
1555.25.1.17
CPI-17
10
180
P-M910
3C X 2.5 Cu.
83
83
1555.25.1.17
CPI-18
181
C-M910
5C X 1.5 Cu.
83
83
1555.25.1.17
CPI-17
10
182
P-M911
3C X 2.5 Cu.
200
200
1555.25.1.17
CPI-18
183
C-M911
5C X 1.5 Cu.
200
200
1555.25.1.17
CPI-17
10
P-M912
3C X 2.5 Cu.
220
220
1555.25.1.17
CPI-18
C-M912
5C X 1.5 Cu.
220
220
1555.25.1.17
CPI-17
10
P-M913
3C X 2.5 Cu.
222
222
1555.25.1.17
CPI-18
C-M913
5C X 1.5 Cu.
222
222
1555.25.1.17
CPI-17
10
184
185
186
187
Page 11 of 34
DOC. NO. :
POWER & CONTROL CABLE SCHEDULE FOR BOILER-01,02 & ASH HANDLING MCC
CLIENT : M/s. INGENIO RISARALDA S. A., COLOMBIA
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
IKE-IJT-IRC51-DOC-032
REV.
DATE
01
16.05.2013
CABLE LUGS
TYPE
FROM
NOTE :-
TO
CABLE SIZE
(mm2)
CABLE LENGTH/
RUNS
RUN
TOTAL LENGTH
(Mtr.)
CABLE
GLANDS
CABLE
(HENSEL CAT GLANDS QTY
NO.)
188
P-M914
3C X 10 Cu.
100
100
1555.32.1.25
CUS-547
189
C-M914
5C X 1.5 Cu.
100
100
1555.25.1.17
CPI-17
10
190
P-M915
3C X 10 Cu.
100
100
1555.32.1.25
CUS-547
191
5C X 1.5 Cu.
100
100
1555.25.1.17
CPI-17
10
192
P-M918
3C X 2.5 Cu.
218
218
1555.25.1.17
CPI-18
193
C-M918
5C X 1.5 Cu.
218
218
1555.25.1.17
CPI-17
10
4C x 2.5 Cu.
50
1555.25.1.17
CPI-18
TCP PANEL
TURBINE SUPERVISORY
PANEL
4C x 2.5 Cu.
50
1555.25.1.17
CPI-18
196
TURBINE SUPERVISORY
PANEL
4C x 2.5 Cu.
50
1555.25.1.17
CPI-18
Page 12 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 13 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 14 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 15 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 16 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 17 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 18 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 19 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 20 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 21 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 22 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 23 of 34
-DOC-032
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
Page 24 of 34
DOC. NO. :
IKE-IJT-IRC51-DOC-030
REV.
DATE
01
16.05.2013
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
SERVICE : 1x159 TPH, BI DRUM, WATER TUBE, TRAVELLING GRATE BOILER
ISGEC JOHN THOMPSON
SL.
NO.
FROM
NOTE :TO
CABLE SIZE
(mm2)
CABLE
CABLE
CABLE LENGTH/ TOTAL LENGTH
CABLE LUGS
GLANDS /TER. GLANDS/TE
RUNS
RUN
(Mtr.)
TYPE
KIT
R.KIT. QTY
CABLE LUGS
QTY
4.16 HT PANEL
ISOLATOR-1
6P1-M201
3C X 120 Cu. HT
33
33
3C X 120 HT KIT
ISOLATOR-1
CONV. TRAFO
6P2-M201
3C X 120 Cu. HT
10
10
3C X 120 HT KIT
CONV. TRAFO
6P3-M201
3C X 120 Cu. HT
10
20
3C X 120 HT KIT
ISOLATOR-1
6P4-M201
3C X 120 Cu. HT
3C X 120 HT KIT
ISOLATOR-2
6P5-M201
3C X 120 Cu. HT
3C X 120 HT KIT
ISOLATOR-2
6P6-M201
3C X 120 Cu. HT
13
13
3C X 120 HT KIT
ISOLATOR-2
BFP-1 MOTOR
6P7-M201
3C X 120 Cu. HT
95
95
3C X 120 HT KIT
BOILER MCC-01
6P8-M201
3C X 4 Cu.
38
38
1555.25.1.17
CUS-543
LPBS(START/STOP/SPU
C-M201-01
P/SPDN)
95
95
1555.32.1.25
CPI-17
20
SP. HEATER
P-M201
2C X 1.5 Cu.
95
95
1555.25.1.17
CPI-17
RPM METER
C-M201-02
2C X 1.5 Cu.Sc.
95
95
1555.25.1.17
CPI-17
4.16 HT PANEL
ISOLATOR-1
6P1-M202
3C X 120 Cu. HT
40
40
3C X 120 HT KIT
ISOLATOR-1
CONV. TRAFO
6P2-M202
3C X 120 Cu. HT
10
10
3C X 120 HT KIT
CONV. TRAFO
6P3-M202
3C X 120 Cu. HT
10
20
3C X 120 HT KIT
ISOLATOR-1
6P4-M202
3C X 120 Cu. HT
3C X 120 HT KIT
ISOLATOR-2
6P5-M202
3C X 120 Cu. HT
3C X 120 HT KIT
ISOLATOR-2
6P6-M202
3C X 120 Cu. HT
13
13
3C X 120 HT KIT
ISOLATOR-2
BFP-2 MOTOR
6P7-M202
3C X 120 Cu. HT
98
98
3C X 120 HT KIT
BOILER MCC-01
6P8-M202
3C X 4 Cu.
42
42
1555.25.1.17
CUS-543
LPBS(START/STOP/SPU
C-M202-01
P/SPDN)
98
98
1555.32.1.25
CPI-17
20
SP. HEATER
2C X 1.5 Cu.
98
98
1555.25.1.17
CPI-17
P-M202
DOC. NO. :
IKE-IJT-IRC51-DOC-030
REV.
DATE
01
16.05.2013
CONSULTANT :----------
EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
SERVICE : 1x159 TPH, BI DRUM, WATER TUBE, TRAVELLING GRATE BOILER
FROM
BFP-2 HT VFD PANEL
NOTE :TO
RPM METER
CABLE SIZE
(mm2)
2C X 1.5 Cu.Sc.
CABLE
CABLE
CABLE LENGTH/ TOTAL LENGTH
CABLE LUGS
GLANDS /TER. GLANDS/TE
RUNS
RUN
(Mtr.)
TYPE
KIT
R.KIT. QTY
1
98
98
1555.25.1.17
CPI-17
CABLE LUGS
QTY
4
DOC. NO. :
IKE-IJT-IRC51-DOC-030
REV.
DATE
01
16.05.2013
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
SERVICE : 1x159 TPH, BI DRUM, WATER TUBE, TRAVELLING GRATE BOILER
ISGEC JOHN THOMPSON
SL.
NO.
NOTE :-
FROM
TO
CABLE SIZE
(mm2)
CABLE
CABLE
CABLE LENGTH/ TOTAL LENGTH
CABLE LUGS
GLANDS /TER. GLANDS/TE
RUNS
RUN
(Mtr.)
TYPE
KIT
R.KIT. QTY
CABLE LUGS
QTY
4.16 HT PANEL
ISOLATOR-1
6P1-M203
3C X 120 Cu. HT
45
45
3C X 120 HT KIT
ISOLATOR-1
CONV. TRAFO
6P2-M203
3C X 120 Cu. HT
10
10
3C X 120 HT KIT
CONV. TRAFO
6P3-M203
3C X 120 Cu. HT
10
20
3C X 120 HT KIT
ISOLATOR-1
6P4-M203
3C X 120 Cu. HT
3C X 120 HT KIT
ISOLATOR-2
6P5-M203
3C X 120 Cu. HT
3C X 120 HT KIT
ISOLATOR-2
6P6-M203
3C X 120 Cu. HT
13
13
3C X 120 HT KIT
ISOLATOR-2
BFP-3 MOTOR
6P7-M203
3C X 120 Cu. HT
101
101
3C X 120 HT KIT
BOILER MCC-01
6P8-M203
3C X 4 Cu.
44
44
1555.25.1.17
CUS-543
LPBS(START/STOP/SPU
C-M203-01
P/SPDN)
101
101
1555.32.1.25
CPI-17
20
SP. HEATER
P-M203
2C X 1.5 Cu.
101
101
1555.25.1.17
CPI-17
RPM METER
C-M203-02
2C X 1.5 Cu.Sc.
101
101
1555.25.1.17
CPI-17
4.16 HT PANEL
ISOLATOR-1
6P1-M435
3C X 120 Cu. HT
44
44
3C X 120 HT KIT
ISOLATOR-1
CONV. TRAFO
6P2-M435
3C X 120 Cu. HT
10
10
3C X 120 HT KIT
CONV. TRAFO
3C X 120 Cu. HT
10
20
3C X 120 HT KIT
ISOLATOR-1
6P4-M435
3C X 120 Cu. HT
3C X 120 HT KIT
6P5-M435
3C X 120 Cu. HT
3C X 120 HT KIT
ISOLATOR-2
6P6-M435
3C X 120 Cu. HT
13
13
3C X 120 HT KIT
ISOLATOR-2
ID FAN-1
6P7-M435
3C X 120 Cu. HT
156
156
3C X 120 HT KIT
BOILER MCC-02
3C X 4 Cu.
38
38
1555.25.1.17
CUS-543
LPBS(START/STOP/SPU
C-M435-01
P/SPDN)
156
156
1555.32.1.25
CPI-17
20
P-M435
2C X 1.5 Cu.
156
156
1555.25.1.17
CPI-17
C-M435-02
2C X 1.5 Cu.Sc.
156
156
1555.25.1.17
CPI-17
DOC. NO. :
IKE-IJT-IRC51-DOC-030
REV.
DATE
01
16.05.2013
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
SERVICE : 1x159 TPH, BI DRUM, WATER TUBE, TRAVELLING GRATE BOILER
ISGEC JOHN THOMPSON
SL.
NO.
NOTE :-
FROM
TO
CABLE SIZE
(mm2)
CABLE
CABLE
CABLE LENGTH/ TOTAL LENGTH
CABLE LUGS
GLANDS /TER. GLANDS/TE
RUNS
RUN
(Mtr.)
TYPE
KIT
R.KIT. QTY
CABLE LUGS
QTY
4.16 HT PANEL
ISOLATOR-1
6P1-M437
3C X 120 Cu. HT
49
49
3C X 120 HT KIT
ISOLATOR-1
CONV. TRAFO
6P2-M437
3C X 120 Cu. HT
10
10
3C X 120 HT KIT
CONV. TRAFO
3C X 120 Cu. HT
10
20
3C X 120 HT KIT
ISOLATOR-1
6P4-M437
3C X 120 Cu. HT
3C X 120 HT KIT
6P5-M437
3C X 120 Cu. HT
3C X 120 HT KIT
ISOLATOR-2
6P6-M437
3C X 120 Cu. HT
13
13
3C X 120 HT KIT
ISOLATOR-2
ID FAN-2
6P7-M437
3C X 120 Cu. HT
142
142
3C X 120 HT KIT
BOILER MCC-02
3C X 4 Cu.
45
45
1555.25.1.17
CUS-543
LPBS(START/STOP/SPU
C-M437-01
P/SPDN)
142
142
1555.32.1.25
CPI-17
20
P-M437
2C X 1.5 Cu.
142
142
1555.25.1.17
CPI-17
C-M437-02
2C X 1.5 Cu.Sc.
142
142
1555.25.1.17
CPI-17
4.16 HT PANEL
ISOLATOR-1
6P1-M445
3C X 120 Cu. HT
54
54
3C X 120 HT KIT
ISOLATOR-1
CONV. TRAFO
6P2-M445
3C X 120 Cu. HT
10
10
3C X 120 HT KIT
CONV. TRAFO
3C X 120 Cu. HT
10
20
3C X 120 HT KIT
ISOLATOR-1
6P4-M445
3C X 120 Cu. HT
3C X 120 HT KIT
6P5-M445
3C X 120 Cu. HT
3C X 120 HT KIT
ISOLATOR-2
6P6-M445
3C X 120 Cu. HT
13
13
3C X 120 HT KIT
ISOLATOR-2
SA FAN-1
6P7-M445
3C X 120 Cu. HT
98
98
3C X 120 HT KIT
BOILER MCC-02
3C X 4 Cu.
45
45
1555.25.1.17
CUS-543
LPBS(START/STOP/SPU
C-M445-01
P/SPDN)
98
98
1555.32.1.25
CPI-17
20
P-M445
2C X 1.5 Cu.
98
98
1555.25.1.17
CPI-17
C-M445-02
2C X 1.5 Cu.Sc.
98
98
1555.25.1.17
CPI-17
DOC. NO. :
IKE-IJT-IRC51-DOC-030
REV.
DATE
01
16.05.2013
CONSULTANT :---------EPC ELECTRICAL CONTRACTOR : M/s. IKE ELECTRIC PVT LTD, PUNE, MAHARASHTRA (INDIA)
SERVICE : 1x159 TPH, BI DRUM, WATER TUBE, TRAVELLING GRATE BOILER
ISGEC JOHN THOMPSON
SL.
NO.
NOTE :-
FROM
TO
CABLE SIZE
(mm2)
CABLE
CABLE
CABLE LENGTH/ TOTAL LENGTH
CABLE LUGS
GLANDS /TER. GLANDS/TE
RUNS
RUN
(Mtr.)
TYPE
KIT
R.KIT. QTY
CABLE LUGS
QTY
4.16 HT PANEL
ISOLATOR-1
6P1-M447
3C X 120 Cu. HT
45
45
3C X 120 HT KIT
ISOLATOR-1
CONV. TRAFO
6P2-M447
3C X 120 Cu. HT
10
10
3C X 120 HT KIT
CONV. TRAFO
3C X 120 Cu. HT
10
20
3C X 120 HT KIT
ISOLATOR-1
6P4-M447
3C X 120 Cu. HT
3C X 120 HT KIT
6P5-M447
3C X 120 Cu. HT
3C X 120 HT KIT
ISOLATOR-2
6P6-M447
3C X 120 Cu. HT
13
13
3C X 120 HT KIT
ISOLATOR-2
SA FAN-2
6P7-M447
3C X 120 Cu. HT
101
101
3C X 120 HT KIT
BOILER MCC-02
3C X 4 Cu.
52
52
1555.25.1.17
CUS-543
LPBS(START/STOP/SPU
C-M447-01
P/SPDN)
101
101
1555.32.1.25
CPI-17
20
P-M447
2C X 1.5 Cu.
101
101
1555.25.1.17
CPI-17
C-M447-02
2C X 1.5 Cu.Sc.
101
101
1555.25.1.17
CPI-17
51-DOC-030
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
51-DOC-030
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
51-DOC-030
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
51-DOC-030
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS
51-DOC-030
PREPARED BY
GMC
APPROVED BY
KBD
REMARKS