Daikin HeatPump

Download as pdf or txt
Download as pdf or txt
You are on page 1of 40

PCVAU0737E

A sp e c i al air conditioning system d esigned f or s m al l-sized buildings

HEAT PUMP
Heat Pump 50 Hz

The ideal air conditioning


Extending the core 5S conceptSpace saving, Sufficient capacity, Slim design, Soundreduced operation and Single phase power supplyDaikins VRV III-S offers added value with the 2E conceptEasy installation and Easy maintenance. With all these features and more, we proudly present the ideal air conditioning system designed for small-sized buildings.

small office
The

5S+2E concepts of

S
5S
concept
1

Space saving Sufficient capacity Slim design

Sound-reduced operation Single phase power supply Easy maintenance Easy installation

E
2E
concept

s and shops
Volume

system for

Slim, compact and sufficient capacity


The VRV III-S is highly space saving, featuring slim and compact outdoor units. It is suitable for small offices and shops with capacities of 4, 5 and 6 class (11.2, 14 and 15.5 kW).

Approx.

reduction

50%

765 mm

320 mm

Footprint
635 mm

Approx.

VRV III (5 class (14 kW))

reduction

40%

900 mm

(4, 5, 6 class (11.2, 14, 15.5 kW))

VRV III (5 class (14 kW)) (4, 5, 6 class (11.2, 14, 15.5 kW))

Outdoor unit can be installed on a balcony


The compact, trunk-shaped outdoor unit can easily be installed on a balcony, realising complete system installation within each floor. This enables more useful utilisation of the space on the building rooftop.

Contents Content
Introduction..............page 1 Main features...........page 3 Control systems.....page 9 Indoor unit lineup.....page 15 Specifications.................page 27
Indoor units............page 27 Outdoor units........page 34

Option list..........................page 35
Indoor units..............page 35 Outdoor units...........page 37 Control systems......page 37
2

MAIN FEATURES
Wide range of choices
To suit the variety of rooms found in small offices and shops, the VRV III-S system offers wide range of indoor and outdoor units. VRV III-S indoor and outdoor units are almost as easy to install as residential air conditioning systems, making them ideal for small offices and shops.

Outdoor units
3 models Outdoor unit can be selected from three models to provide the power that suits your needs. The trunk-shaped outdoor unit can be neatly installed.
RXYMQ4PV4A 4 class (11.2 kW) RXYMQ5PV4A 5 class (14 kW) RXYMQ6PV4A 6 class (15.5 kW)

Indoor units
14 types 78 models A wide range of indoor units includes 78 models in 14 types. The indoor units can be selected to match rooms and preferences.

Indoor unit lineup 14 types 78 models


Type
Ceiling Mounted Cassette (Round Flow) Ceiling Mounted Cassette (Compact Multi Flow) Ceiling Mounted Cassette (Double Flow) Ceiling Mounted Cassette Corner

Model Name

Capacity Range 2.2 kW 2.8 kW 3.6 kW 4.5 kW 5.6 kW 7.1 kW 9 kW 11.2 kW 14 kW 16 kW 16.2 kW Capacity Index 20 25 31.25 40 50 62.5 80 100 125 140 145

FXFQ-PVE FXZQ-MVE FXCQ-MVE FXKQ-MAVE FXDQ-PBVE


(700 mm width type)

Slim Ceiling Mounted Duct

FXDQ-NBVE
(900/1,100 mm width type)

Ceiling Mounted Built-in Ceiling Concealed (Duct) Ceiling Mounted Duct

New FXSYQ-MVE

New

New

New

New

New

New

New

New

New

FXDYQ-MAV1 FXMQ-PVE FXHQ-MAVE FXAQ-MAVE FXLQ-MAVE FXNQ-MAVE


New

Ceiling Suspended Wall Mounted Floor Standing Concealed Floor Standing

Note: R-410A VRV system indoor units are not compatible with the R-22 VRV system.

Connection unit series indoor units


Type
Ceiling Suspended Cassette

Model Name

Capacity Range Capacity Index Connection Unit

2.2 kW 20

2.8 kW 25

3.6 kW 31.25

4.5 kW 40

5.6 kW 50

8 kW 71
BEVQ71MAVE

11.2 kW 100

14 kW 125

BEVQ100MAVE BEVQ125MAVE

FXUQ-MAV1

Note: BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data for details.

MAIN FEATURES
Energy efficiency and quiet operation
Outdoor units use Daikins unique scroll compressor to realise energy saving performance and quiet operation.
High COP achieved in all ranges!

High COP during both cooling and heating operations


Cooling
4 class (11.2 kW) 5 class (14 kW) 6 class (15.5 kW)

VRVII-S
Previous model RXYMQ-MV4A

3.07 2.81 2.82 3.27 3.58 3.45

One of the top features of the VRV III-S is its energy efficiency. It achieves high COP during cooling and heating operations by utilising Daikins unique scroll compressor.

Heating

4 class (11.2 kW) 5 class (14 kW) 6 class (15.5 kW)

3.15 2.94 3.03 3.37 3.73 3.62

Above values are based on the following nominal conditions: 2 built-in units are connected (4 class (11.2 kW): FXSYQ50M x 2; 5 class (14 kW): FXSYQ63M x 2; and 6 class (15.5 kW): FXSYQ63M + FXSYQ80M.) Cooling: Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

Quiet operation provides luxurious comfort


Quietness is yet another important feature of Daikins VRV III-S system. To reduce noise and realise comfortable operation, latest technologies and features are applied to the outdoor units.

Lower operation sound is achieved! VRVII-S


Previous model RXYMQ-MV4A

1 dB(A) reduced in each model!

Cooling

4 class (11.2 kW) 5 class (14 kW) 6 class (15.5 kW)

51 52 54 53 54 56

-1dB(A) -1dB(A) -1dB(A) -1dB(A) -1dB(A) -1dB(A)

Heating

4 class (11.2 kW) 5 class (14 kW) 6 class (15.5 kW)

50 51 53 52 53 55

Nighttime quiet operation function


Operation sound level selectable from 3 steps for the night mode
Mode 1. Automatic mode Mode 1. Automatic mode

Capacity %

Peak in outdoor temperature

Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will initiate 8 hours*1 after the peak temperature in the daytime, and normal operation will resume 10 hours*2 after that. The operation sound level for the night mode can be selected from 47 dB(A) (Step 1), 44 dB(A) (Step 2) and 41 dB(A) (Step 3).
Mode 2. Manual mode

100

Load %

8 hrs
50

(Initial setting)

10 hrs

(Initial setting)

Operation sound dB(A)

0 50
Step 1 max. - 3dB(A) ( 4 class/11.2 kW)

Night Mode

Starting time and ending time can be input. (An external control adaptor for outdoor unit, DTA104A53/61/62, and a locally obtained timer are necessary.)
Mode 3. Combined mode

Step 1: 47 dB(A)

47 44 41 8:00

Step 2 max. - 6dB(A) ( 4 class/11.2 kW) Step 3 max. - 9dB(A) ( 4 class/11.2 kW)

Step 2: 44 dB(A) Step 3: 41 dB(A)

Combinations of modes 1 and 2 can be used depending on your needs.


*1. Initial setting. Can be selected from 6, 8 and 10 hours. *2. Initial setting. Can be selected from 8, 9 and 10 hours.

Night mode starts


12:00 16:00 20:00

Night mode ends


0:00 4:00 8:00

Note: This function is available in setting at site. The relationship of outdoor temperature (load) and time shown in the graph is just an example. The capacity reduction rate differs depending on the operation sound level step selected.

A collection of cutting-edge technologies results in efficient and quiet operation.


Improving the high efficiency compressor to achieve a high COP
1 5 3

Reluctance DC Scroll Compressor


Overheating losses are reduced by pressurising the area around the motor, boosting energy saving performance in conjunction with other features. High thrust mechanism
By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound levels.
Reluctance DC motor

>> Powerful magnets


Use of neodymium magnets in the motor enables efficient generation of high torque, reducing the size of the compressor.
Neodymium magnets are well known for their powerfulness compared to commonly used ferrite magnets.

RXYMQ4PV4A RXYMQ5PV4A RXYMQ6PV4A

>> Smooth sine wave DC inverter


Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency.
Sine wave DC inverter

>> Stronger materials


The strength of the casing has been increased by boosting the internal dome pressure. 2

>> Optimal refrigerant configuration


Changes to the shape of the spiral and volume ratio result in optimal refrigerant layout.

Smooth Air Inlet Bell Mouth and Aero Spiral Fan


These two features work to significantly reduce noise. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence.

With the bent blade edge

Without the bent blade edge

Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence.
DC motor efficiency
(comparison with a conventional AC motor)
100 80 60 40 Approx. 20 increase 0 200 300

DC fan motor
Efficiency improved in all areas compared to conventional AC motors, especially at low speeds.
DC fan motor structure

Efficiency (%)

DC motor

Approx. increase

20%

40%

AC motor

400 500

600

700 800

900 1000

Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory.

Motor speed (rpm)

Super Aero Grille


Refined ventilation mechanism enables further reduction in required fan power.

SC heat exchanger
A larger sub-cooled area reduces refrigerant flow sound by making it easer to form a liquid seal in front of the electrical valve.
6

MAIN FEATURES
Design flexibility
VRV III-S systems offer broad design flexibility with long refrigerant piping lengths and multiple indoor unit combinations, which provides generous freedom for office and shop design both inside and out.

Up to 9 indoor units can be connected to a single outdoor unit


Multiple indoor unit combinations are possible.* As many as 9 indoor units can be connected to a 6 class (15.5 kW) unit, making the VRV III-S a versatile system.
* Indoor units can be connected up to 130% of the capacity of the outdoor unit.

For a 6 class (15.5 kW) installation

Max.

9
5 6 7 8 9

units

>> Max. 8 indoor units for a 5 class (14 kW) installation >> Max. 6 indoor units for a 4 class (11.2 kW) installation

Long piping design possible


The VRV III-S provides the long piping length possibility of 150 m, with a total piping length of 300 m. If the outdoor unit is installed above indoor units the level difference can be up to a maximum of 50 m. These generous allowances facilitate an extensive variety of system designs.
Actual piping length Total piping length

*2 Max.

50 m*1

Level difference

Max.

Level difference between indoor units

15 m

Max.

150

Max.

300

Note: *1. 40 m when the outdoor unit is installed below indoor units. *2. Maximum piping length between the indoor unit and the first branch is 40 m.

Wide operation temperature range


50
Outdoor temperature (CDB)

Certified operation temperature range

40 30 20 10 0 -10 -5CDB Cooling

The operation range of the VRV III-S system works to reduce limitations on installation locations. The operation temperature range for heating goes all the way down to -20C, while cooling can be performed with outdoor temperatures as high as 46C. Both these achievements are due to the adoption of a highpressure dome-type compressor.

Outdoor temperature (CWB)

46CDB

20 10 0 -10 -20

15.5CWB

-20CWB Heating

Easy installation
A variety of functions are provided that make installation easier, such as simple wiring and piping and automatic test operation.
Previous model VRV II-S

Easy wiring
A printed circuit board has been adopted that is much easier to see and wire during installation.

Automatic test operation


Simply press the test operation button after refrigerant charging is completed, and the unit performs an automatic system check, including wiring, shutoff valves, and sensors. The results are returned automatically after the check finishes.

Simple wiring and piping connection


Unique piping and wiring systems make it possible to install a VRV III-S system quickly and easily.
>> Super wiring system
A super wiring system is used to enable shared use of the wiring between indoor and outdoor units and the central control wiring, with a relatively simple wiring operation. The DIII-NET communication system is employed to enable the use of advanced control system.

>> REFNET piping system


Daikins advanced REFNET piping system makes installation easy. Only two main refrigerant lines are required in any one system. REFNET greatly reduces the imbalances in refrigerant flow between units, while using small-diameter piping.

Outdoor unit Central remote controller Indoor unit

Easy maintenance
VRV III-S features a memory function that helps to identify the problem if a malfunction occurs.

Memory function for operation data


Operating data for the preceding 3 minutes is automatically stored in memory. Should a malfunction occur, this speeds up the process of identifying and fixing the cause of the problem.

CONTROL SYSTEMS
Control systems
The VRV III-S system uses the same DIII-NET communication system as the VRV, enabling the use of advanced control systems.

Individual control systems


Wired remote controller (Option)
Digital display lets you set temperature in 1C units. Lets you individually programme by timer the respective times for operation start and stop within a maximum of 72 hours. Equipped with a thermostat sensor in the remote controller that makes possible more comfortable room temperature control. Enables you to select cool/heat/fan operation mode with the indoor remote controller of your choice without using the cool/heat selector. (dependant on system) Equipped with self-diagnosis function that constantly monitors the system for malfunctions. Should a problem occur, the system alerts you of the problem through an alphanumeric code. The rubber switch and the oil-resisting resin casing have been adopted for durability.
* When the auto-swing function is not available, the message, THIS FUNCTION IS NOT AVAILABLE is displayed when the air direction adjustment button is pressed.

BRC1C62

Wired remote controller with weekly schedule timer (Option)


Adds advanced functions to those of the above wired remote controller.
Includes ventilation mode and airflow rate switching, the main functions of HRV series. 24-hour clock function (1-hour backup for power failures) Programming function for each day of week. Scheduling possible of start/stop and temperature limit (5 settings/day) Programming can be enabled or disabled. Copy function for programmed schedules.
Notes: 1. Standard remote controllers (BRC1C62) not required. 2. If the BRC1D61 is connected to the centralised remote controllers (DCS303A51, DCS302CA61,DCS301BA61, DST301BA61), the schedule function is not available.

BRC1D61

The wired remote controller supports a wide range of control functions


Control of Cool/Heat In all the series of VRV, Cool/Heat changeover in the same refrigerant circuit can be changed by the master remote controller of an indoor unit. changeover Group control
Outdoor unit

Control by two remote controllers

Equipment related to the central control

One remote controller can control the operation of max.16 indoor units at the same time.

The indoor unit can be connected by the two remote controller, for example one in the room and the other one in the control room, which can control the operation of indoor unit freely. (The last command has a priority.) Of course, the group control by two remote controllers is also possible.

2
Remote controller Remote controller Indoor unit

Remote control

The wiring of remote controller can be extended to max.500 m and it is possible to install the remote controllers for the different indoor units in one place.

Remote controller

3 Control for the combined operation


Forced OFF input HRV

The operation of HRV can be controlled by the remote controller of the indoor unit. Of course, the remote controller can display the time to clean the filter.

Remote controller

Remote controller

Remote controller Remote controller Remote controller

Expansion of system control

The system can be expanded to add several controllers, such as BMS, Forced OFF input and etc.

Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit.

Wireless remote controller (Option)


The same operation modes and settings as with wired remote controllers (BRC1C62 only) are possible. A compact signal receiver unit (separate type) to be mounted into a wall or ceiling is included. A signal receiver unit (installed type) for a Ceiling Mounted Cassette (Round Flow, Compact Multi Flow, Double Flow) type, Ceiling Suspended type and Wall Mounted type is mounted into the indoor unit. Signal receiver unit can be installed on the panel
ex. Ceiling Mounted Cassette (Round Flow) type

Signal receiver unit


(Separate type)

Wireless remote controller *Wireless remote controller and signal receiver unit are sold as a set. * Refer to page 37 for the name of each model.

Signal receiver unit


(Installed type)

Simplified remote controller (Option)


The remote controller has centralised its frequently used operation selectors and switches (on/off, operation mode, temperature setting and airflow volume), making itself suitable for use in hotel rooms or conference rooms. The exposed type remote controller is fitted with a thermostat sensor.

Concealed type
(For hotel use) (BRC3A61)

Exposed type
(BRC2C51)

The concealed type remote controller smartly fits into a night table or console panel in a hotel room.

Wide variation of remote controllers for indoor units


FXFQ Wired remote controller
(BRC1C62)

FXZQ

FXCQ

FXKQ

FXDQ

FXSYQ FXDYQ

FXMQ

FXHQ

FXAQ

FXL(N)Q

FXUQ

Wired remote controller with weekly schedule timer


(BRC1D61)

Wireless remote controller*


(Installed type signal receiver unit)

Wireless remote controller*


(Separate type signal receiver unit)

Simplified remote controller


(Exposed type) (BRC2C51)

Simplified remote controller


(Concealed type: for Hotel use) (BRC3A61)

* Refer to page 37 for the name of each model.

10

CONTROL SYSTEMS
Centralised control systems
Up to 64 groups of indoor units (128 units) can be centrally controlled. Optional controllers for centralised control can be combined and optimised in accordance with building scale and purpose. System integration with various air-conditioning peripheral equipment such as HRV (Heat Reclaim Ventilation) is easy. Wiring can be run up to a total length of 2 km, and adapts easily to large-scale system expansion.

Unified on/off controller (DCS301BA61) Connection of up to 8 units possible Address setting of central control can be performed from the remote controller.

Independent and centralised control of HRV is possible.

Connectable number of centralised control equipment Central remote controller Unified on / off controller Schedule timer 2 units 8 units 1 unit Group control of up to 16 units is possible 1 (group control via automatic address setting)

System without remote control is also available.

Forced shut-down input

Central control adaptor kit (DTA107A55)

Wiring adaptor for other airconditioners (DTA103A51)

Outdoor-air processing unit can be connected.

Central remote controller (DCS302CA61) Up to 2 units connectable

Interface adaptor for SkyAir series (built-in indoor unit) (DTA102A52)

6 cores Schedule timer (DST301BA61) 1 unit connection possible ; 8 weekly schedule control patterns possible

7 cores max.

Interlink Building Management System (host computer monitor panel) also possible

Unification adaptor for computerised control (DCS302A52)

1. Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit. Certain indoor units limit the functions of some control systems.

For more details, please refer to the Engineering Data.

11

Residential central remote controller* (Option)


Max. 16 groups of indoor units can be easily controlled with the large LCD panel.
Max. 16 groups (128 indoor units) controllable Backlight and large LCD panel for easy readability ON/OFF, temperature settings and scheduling can be controlled individually for indoor units. All indoor units can be turned on or off at once with ALL button. Each group has a dedicated button for convenience. Outside temperature display
DCS303A51
* For residential use only. Cannot be used with other centralised control equipment.

Central remote controller (Option)


Max. 64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller.
Max. 64 groups (128 indoor units) controllable Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers, which can control from 2 different places. Zone control Malfunction code display Max. wiring length 1,000 m (Total: 2,000 m) Connectable with Unified ON/OFF controller, schedule timer and BMS system Airflow volume and direction can be controlled individually for indoor units in each group operation. Ventilation volume and mode can be controlled for Heat Reclaim Ventilation (HRV). Up to 4 ON/OFF pairs can be set per day by connecting a schedule timer.

DCS302CA61

Unified ON/OFF controller (Option)


Max. 16 groups of indoor units can be operated simultaneously/individually.
Max. 16 groups (128 indoor units) controllable 2 remote controllers can be used to control from 2 different places. Operating status indication (Normal operation, Alarm) Centralised control indication Max. wiring length 1,000 m (Total: 2,000 m) Compact size casing (Thickness: 16 mm) Connectable with Central Remote controller, Schedule timer and BMS system

DCS301BA61

Schedule timer (Option)


Max. 128 indoor units can be operated as programmed schedule.
Max. 128 indoor units controllable When used in combination with a central remote controller, a maximum of 8 weekly schedule patterns can be set, while the central controller can be used to select desired zones. Up to 2 ON/OFF pairs can be set per day. Max. 48 hours back up power supply Max. wiring length 1,000 m (Total: 2,000 m) Compact size casing (Thickness: 16 mm) Connectable with Central Remote controller, Unified ON/OFF controller and BMS system

DST301BA61

12

CONTROL SYSTEMS
Advanced control systems

Communication functions in the user-friendly icon-based multilingual controller simplify centralised control of the VRV system.
Colour LCD touch panel icon display Small manageable size Simplified engineering Multi language (English, French, Italian, German, Spanish, Dutch, Portuguese, Chinese and Korean) Yearly schedule PPD (Power Proportional Distribution function) (Option) Auto heat/cool change-over Temperature limitation Enhanced history function Air Conditioning Network Service System (Optional Maintenance Service) Simple Interlock Function
CSV output of power proportional distribution results (Option)

PCMCIA Flash Memory

Function 1

Remote monitoring and control

DCS601C51
Pi Port Via internet Air Conditioning Network Service System modem for connections Connection to power consumption meter when using power proportional distribution function. (Option)

Function 2

Function 3

System Components
ACC centre
Air Conditioning Network Service System (Optional Maintenance Service)

Trouble reports
Mobile Phone PC

13

Function 1
Support for centralised control from elsewhere using a PC with a Web browser (Option)

Function 4
Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option)

Function 2
Sending of e-mail alerts to a specified address when malfunctions occur (Option)

Function 5
Management of facilities/equipment other than A/C units (By adding Dio unit or Di unit)

Function 3
Built-in modem for connecting to Air Conditioning Network Service System (Option)

Function 6
Simple Interlock Function

Dio Unit DEC102A51 (Option)

Di Unit DEC101A51 (Option)

Function 5
Input (Lights) Input (Key signal General purpose ADP)

System

Set temperature change command

OFF command

Function 6

D -NET RS-232C

Indoor Unit D -NET Plus Adaptor DCS601A52 (Option) Number of indoor units expanded from 64 to 128.

HRV

Function 4

14

INDOOR UNIT LINEUP


Ceiling Mounted Cassette (Round Flow) Type
FXFQ25P/ FXFQ32P/ FXFQ40P FXFQ50P/ FXFQ63P/ FXFQ80P FXFQ100P/ FXFQ125P
GOOD DESIGN AWARD IN JAPAN

360 airflow improves temperature distribution and offers a comfortable living environment.
The industrys first* Round Flow Ceiling Mounted Cassette type offers 360 airflow with improved temperature distribution.
4-way flow

Round Flow

There are areas of uneven temperature.

There are much fewer areas of uneven temperature.

* As of April 2004, the release date for Japan.

All models are lighter than the conventional ones. Ex: Models FXFQ25P-50P are 4.5 kg lighter (reduced from 24 kg to 19.5 kg). Drain pump is equipped as standard accessory, and the 850 mm lift height has been improved from 750 mm to 850 mm. A modern sophisticated decoration panel has been applied, with a panel surface that has been treated with a dirt-repellant coating.
Treated surface Untreated surface
Dirt and grime Condition after exposure to the smoke of 600 3 cigarettes in 1 m enclosed space.

An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours. The horizontal louvres prevent dew condensation. Their non-flocking surfaces, which repel dirt, are easy to clean. The air filter has an anti-mould and antibacterial treatment that prevents the growth of mould generated from dust or moisture that may adhere to the filter.
4-way flow 3-way flow L-shaped 2-way flow

Resists soiling

Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level
FXFQ-P 25/32 40 50 63 80 100 (dB(A)) 125

Sound level 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 (HH/H/L)

Example of airflow patterns:


360 airflow is available, as well as 2- to 4-way flows, so you can choose the most suitable airflow pattern depending on location or room layout.

All-round flow

Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to close each unused outlet.

15

Ceiling Mounted Cassette (Compact Multi Flow) Type


FXZQ20M / FXZQ25M FXZQ32M / FXZQ40M FXZQ50M

Quiet, compact, and designed for user comfort


Dimensions correspond with 600 mm X 600 mm architectural module ceiling design specifications. Low operation sound level
(240 V)(dB(A))

FXZQ-M Sound level (H/L)

20/25 32/26

32 34/28

40 37/29

50 42/35

Comfortable airflow
1

Wide discharge angle: 0 to 60


Auto swing Fixed angles: 5 levels

0 60 60

0 60 60

Angles can be also set on site to prevent drafts (0-35) or soiling of the ceiling (25-60), other than standard setting (0-60).

2-, 3-, and 4-way airflow patterns are available, enabling installation in the corner of a room. Drain pump is equipped as standard accessory with 750 mm lift.

4-way flow

3-way flow

L-shaped 2-way flow

750 mm

For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close each unused outlet.

16

INDOOR UNIT LINEUP


Ceiling Mounted Cassette (Double Flow) Type
FXCQ20M / FXCQ25M / FXCQ32M FXCQ40M / FXCQ50M / FXCQ63M FXCQ80M / FXCQ125M

Thin, lightweight, and easy to install in shallow ceiling spaces


The low profile unit (only 305 mm high) can be installed in a ceiling space as shallow as 350 mm. All models feature a compact design with a depth of only 600 mm.

305 mm

(When a high-efficiency filter is attached, the unit's height is 400 mm.)

Low operation sound level


FXCQ-M 20 25/32 40/50 63

(240 V)(dB(A))

80

125

Sound level (H/L) 34/29 36/30 37/32 39/34 41/36 46/40

Designed with higher airflow suitable for high ceiling application up to 3 metres. Providing 2 different settings of standard and ceiling soiling prevention, the auto swing mechanism achieves even distribution of airflow and room temperature. Drain pump is equipped as standard accessory with 600 mm lift.

Two types of optional high-efficiency filter are available (65% and 95%, colourimetric method). A long-life filter (maintenance free up to one year) is equipped as standard accessory. Major maintenance work can be performed by removing the panel. A flat-type suction grille and a detachable blade make cleaning easy.

600 mm

17

Ceiling Mounted Cassette Corner Type


FXKQ25MA / FXKQ32MA FXKQ40MA / FXKQ63MA

Slim design for flexible installation


Slim body needs only 220 mm space above the ceiling. If you use a panel spacer (option), the unit can be installed in the minimum space of 195 mm.
Min.195 mm Panel spacer 20 mm

Providing 3 different settings of standard, draft prevention and ceiling soiling prevention, the auto swing mechanism achieves even distribution of airflow and room temperature.
(m) 3 2 1 28C 32C 30C 26C 24C 22C 20C 1 2 3 4 5 6 (m)

Single-flow type allows effective air discharge from corner or from drop-ceiling. Drain pump is equipped as standard accessory with 500 mm lift.
500 mm

Front discharge is possible with an air discharge unit (option), which allows the installation in the drop-ceiling or sagging wall.
Main body

Downward discharge

Air discharge grille (Option)

Set for front discharge using a suspended ceiling.

Main body

Air discharge grille (Option)

Downward discharge is shut off and air is blown straight out (front discharge).

A long-life filter (maintenance free up to one year) is equipped as standard accessory.


18

INDOOR UNIT LINEUP


Slim Ceiling Mounted Duct Type
Slim design, quietness and static pressure switching
Suited for use in drop-ceilings!
FXDQ40NB/FXDQ50NB/FXDQ63NB FXDQ20PB/FXDQ25PB/FXDQ32PB
Only 700 mm in width and 23 kg in weight, this model is suitable to install in limited spaces like drop-ceilings in hotels. Great for hotel use! Only 200 mm in height, this model can be installed in rooms with as little as 240 mm depth between the drop-ceiling and ceiling slab.

200 mm
Only

900 mm

200 mm
1,100 mm in width for the FXDQ63NB model.

700 mm

Suspension bolt*

Air filter

AIR

240 mm
Suction grille* AIR

Discharge grille*

* To be obtained locally

External static pressure selectable by remote controller switching make this indoor unit a very comfortable and flexible model.
10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models. 15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

Drain pump is equipped as standard accessory with 750 mm lift. Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level
FXDQ-PB/NB Sound level (HH/H/L) 20/25/32 33/31/29 40 34/32/30 50 35/33/31 (dB(A)) 63 36/34/32
Ceiling

750 mm

The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.

19

Ceiling Mounted Built-in Type


FXSYQ20M/FXSYQ25M/FXSYQ32M New FXSYQ40M/FXSYQ50M/FXSYQ63M FXSYQ80M/FXSYQ100M/FXSYQ125M

Highly flexible for various application


Highly flexible installation is possible with a complete lineup of optional kits to satisfy various needs, such as the design concept, interior decoration and so on. The unit can be installed, if there is a space of 350 mm above ceiling. (when suction panel is used.)
Min. 350 mm Screening door

Installation examples ( Optional parts)


Standard Cassette style (standard filter)
Long-life filter Air suction canvas bellows Long-life filter Air suction panel

Cassette style (high efficiency filter) With duct


High efficiency filter Air suction canvas bellows Air suction panel Access panel

Ceiling return
Long-life filter

Drain pump is equipped as standard accessory with 250 mm lift.


250 mm

Access panel

High external static pressure allows the use of flexible ducts of various length. Low operation sound level
FXSYQ-M Sound level (H/L) 20/25/32 40 50 43/37 63 45/38.5 41/33.5 41/34.5
(230 V)(dB(A))

80/100 48/43

125 49/41.5

The values of operation sound level are based on Australian Standard 1217.6-1985. Measurement is based on bottom-return air entry.

20

INDOOR UNIT LINEUP


Ceiling Concealed (Duct) Type
FXDYQ80MA/FXDYQ100MA FXDYQ125MA/FXDYQ145MA

High static pressure offers flexible duct design that blends in with interior dcor in stores and offices
High efficiency Hi-X heat exchanger coils that provide energy savings.

High external static pressure of 120 Pa allows comprehensive duct layout for various applications.

Design of indoor units allows installation in limited roof spaces.

Return air spigots included for ease of installation.

Two external static pressure settings for added flexibility.

Quiet yet powerful supply air fan.

High strength galvanised steel casing.

21

Ceiling Mounted Duct Type


FXMQ20P/ FXMQ25P/ FXMQ32P FXMQ40P/ FXMQ50P/ FXMQ63P FXMQ80P/ FXMQ100P/ FXMQ125P FXMQ140P New

Middle and high static pressure allows for flexible duct design
A DC fan motor increases the external static pressure capacity range to include middle to high static pressures, increasing design flexibility.
30 Pa100 Pa for FXMQ20P-32P 30 Pa160 Pa for FXMQ40P 50 Pa200 Pa for FXMQ50P-125P 50 Pa140 Pa for FXMQ140P

All models are only 300 mm in height, an improvement over the 390 mm height of conventional models. The weight of the FXMQ40P has been reduced from 44 kg to 28 kg.

300 mm
Easy installation in buildings with narrow ceiling spaces

Drain pump is equipped as standard accessory with 700 mm lift.


700 mm
Ceiling

Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level
FXMQ-P 20/25 32 40 50 63 80/100 125 (dB(A)) 140

Sound level 33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 46/45/43 (HH/H/L)

Improved ease of installation Airflow can be controlled using a remote controller. With the conventional model, the airflow rate was controlled from the PC board. It is automatically adjusted to the range between approximately 10% of the rated HH tap airflow for FXMQ20P-125P. Improved ease of maintenance The drain pan can be detached for easy cleaning. An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours.
22

Energy-efficient The adopted DC fan motor is much more efficient than the conventional AC motor, yielding an approximate 20% decrease in energy consumption (FXMQ125P).

INDOOR UNIT LINEUP


Ceiling Suspended Type
FXHQ32MA / FXHQ63MA FXHQ100MA

Slim body with quiet and wide airflow


Adoption of QUIET STREAM FAN
Uses the quiet stream fan and many advanced technologies.
Sound absorption material

Turbulent flow is produced

Quiet stream fan Straightening vane

Low operation sound level


FXHQ-MA Sound level (H/L) 32 36/31 63 39/34

(dB(A)) 100 45/37

Installation is easy Drain pump kit (option) can be easily incorporated.


600 mm

Drain pump kit (Built inside main unit)

Maintenance is easy Non-dew Flap with no implanted bristles


Bristle-free Flap minimises contamination and makes cleaning simpler.

Wide air discharge openings produce a spreading 100 airflow.

Easy-to-clean flat design

Non-dew Flap

Maintenance is easier because servicing can be performed from below the unit. A long-life filter (maintenance free up to one year) is equipped as standard accessory.
100

23

Wall Mounted Type


FXAQ20MA / FXAQ25MA FXAQ32MA/FXAQ40MA FXAQ50MA / FXAQ63MA

Sophisticated design and compact casing harmonised with your interior dcor
Compact and stylish design that does not detract from the dcor of the room. Low operation sound level
FXAQ-MA Sound level (H/L) 20 35/29 25 36/29 32 37/29 40 39/34 50 42/36

(dB(A)) 63 46/39

Drain pan and air filter can be kept clean by mildew-proof polystyrene. Washable grille, the front grille can be easily removed for washing. Auto-swing realises efficiency of air distribution. The louvre closes automatically when the unit stops.

5 steps of discharge angle can be set by remote controller. Discharge angle is automatically set at the same angle as the previous operation when restarting. (Initial setting: 10 for cooling and 70 for heating) Flexible installation Drain pipe can be fitted to from either left or right sides.

Drain pump kit is available as optional accessory, which lifts the drain 1,000 mm from the bottom of the unit.
Height of drain-up

1,000 mm

Indoor unit Drain pump kit

24

INDOOR UNIT LINEUP


Floor Standing Type
FXLQ20MA / FXLQ25MA FXLQ32MA/FXLQ40MA FXLQ50MA / FXLQ63MA

Suitable for perimeter zone air conditioning


Floor Standing types can be hung on the wall for easier floor cleaning. Running the piping from the back allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier. The adoption of a fibre-less discharge grille featuring an original design to prevent condensation also helps prevent staining and makes cleaning easier. A long-life filter (maintenance free up to one year) is equipped as standard accessory.
Wall hanging Floor installation

Concealed Floor Standing Type


FXNQ20MA / FXNQ25MA FXNQ32MA / FXNQ40MA FXNQ50MA / FXNQ63MA

Designed to be concealed in the perimeter skirting-wall


The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design. The connecting port faces downward, greatly facilitating on-site piping work. A long-life filter (maintenance free up to one year) is equipped as standard accessory.

Connecting port Refrigerant piping


Applies also to Floor Standing type (FXLQ-MA).

25

Ceiling Suspended Cassette Type


FXUQ71MA FXUQ100MA FXUQ125MA

This thin indoor unit achieves optimum air distribution, and can be installed without the need for ceiling cavity
Depending on installation site requirements or room conditions, 2-way, 3-way and 4-way discharge patterns are available.

4-way airflow from the centre of the store.

The 3-way airflow can distribute comfortable air throughout the room.

Only one unit is needed to distribute comfortable air throughout an L-shaped store.

Connection unit

Connection unit is the device for connecting above indoor unit to VRV III-S.

BEVQ71MA/BEVQ100MA/BEVQ125MA
Refrigerant piping layout
Connection unit for indoor unit

External wiring layout

*1 Model FXUQ-MA

Maximum piping length between the BEV unit and the indoor unit. 5m

VRV -S series outdoor unit Liquid pipe Gas pipe


BEVQ-MA

Super wiring ( DIII-NET ) Single-phase 220-240 V power supply Indoor unit

Piping length*1

Indoor unit Remote controller

Notes: When connecting centralised-control device, it is necessary to install an interface adaptor for an indoor unit (DTA102A52). Connection unit BEVQ-MA is necessary for each indoor unit. The refrigerant piping height difference between the indoor units and the BEV unit must be within 4 m. The BEV unit must be installed within a maximum height difference between indoor units of 15 m. Branching of the refrigerant piping is not possible downstream of the BEV unit.

26

SPECIFICATIONS
INDOOR UNITS
Ceiling Mounted Cassette (Round Flow) Type
MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2) 2,500 9,900 2.9 2.8 2,800 10,900 3.2 0.033 0.027 3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.033 0.027

FXFQ25PVE FXFQ32PVE FXFQ40PVE FXFQ50PVE FXFQ63PVE FXFQ80PVE FXFQ100PVE FXFQ125PVE


1-phase, 220-240 V/220 V, 50/60 Hz 4,000 16,000 4.7 4.5 4,300 17,100 5.0 0.047 0.034 5,000 19,800 5.8 5.6 5,400 21,500 6.3 0.052 0.038 6,300 24,900 7.3 7.1 6,900 27,300 8.0 0.066 0.053 8,000 31,700 9.3 9.0 8,600 34,100 10.0 0.093 0.075 10,000 39,600 11.6 11.2 10,800 42,700 12.5 0.187 0.174 12,500 49,500 14.5 14.0 13,800 54,600 16.0 0.209 0.200

kcal/h Heating capacity Cooling Heating kW Btu/h kW Power consumption Casing Airflow rate (HH/H/L) Sound level (HH/H/L) Sound power (HH/H/L) Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain Model Panel (Option) Colour Dimensions (HXWXD) Weight mm kg mm /s m3/min dB(A) dB(A) mm kg

Galvanised steel plate 216/191/166 216/191/166 250/216/183 266/225/183 316/275/225 350/300/250 533/433/333 550/466/375 13/11.5/10 13/11.5/10 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 32/26/20 33/28/22.5 44/39/34

30/28.5/27 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32

48/46.5/45 48/46.5/45 49/47/45 50/47.5/45 52/49/46 53/51.5/49 60/54.5/50 61/56/52 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 288X840X840 288X840X840 19.5 6.4 12.7 19.5 6.4 12.7 19.5 6.4 12.7 19.5 6.4 12.7 22 9.5 15.9 22 9.5 15.9 25 9.5 15.9 25 9.5 15.9

VP25 (External Dia, 32/Internal Dia, 25) BYCP125K-W1 Fresh white 50X950X950 5.5 50X950X950 5.5 50X950X950 5.5 50X950X950 5.5 50X950X950 5.5 50X950X950 5.5 50X950X950 5.5 50X950X950 5.5

Ceiling Mounted Cassette (Compact Multi Flow) Type


MODEL
Power supply kcal/h(*1) Btu/h(*1) Cooling capacity kW (*1) (*2) 2,000 7,800 2.3 2.2 2,200 8,500 2.5 0.073 0.064 150/116 9/7 32/26 49

FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE


1-phase, 220 - 240 V/220 V, 50 Hz/60 Hz 2,500 9,900 2.9 2.8 2,800 10,900 3.2 0.073 0.064 150/116 9/7 32/26 49 3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.076 0.068 Galvanised steel plate /s m3/min 158/125 9.5/7.5 34/28 51 286X575X575 18 6.4
mm

4,000 16,000 4.7 4.5 4,300 17,100 5.0 0.089 0.080 183/133 11/8 37/29 54

5,000 19,800 5.8 5.6 5,400 21,500 6.3 0.115 0.107 233/166 14/10 42/35 59

kcal/h Heating capacity


Power consumption Cooling Heating

Btu/h kW kW

Casing Airflow rate (H/L) Sound level (H/L) Sound power (H) Machine weight
Liquid (Flare) Piping connections Gas (Flare) Drain

240 V 240 V

dB(A) dB(A) mm kg

Dimensions (HXWXD)

6.4 12.7

6.4 12.7 BYFQ60B8W1 White (6.5Y9.5/0.5)

6.4 12.7

6.4 12.7

12.7

VP20 (External Dia, 26/Internal Dia, 20)

Model Panel (Option) Colour Dimensions (HXWXD) Weight mm kg 55X700X700 2.7 55X700X700 2.7

55X700X700 2.7

55X700X700 2.7

55X700X700 2.7

Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35.0CDB. (*2) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

27

INDOOR UNITS
Ceiling Mounted Cassette (Double Flow) Type
MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2) 2,000 7,800 2.3 2.2 2,200 8,500 2.5 0.077 0.044 2,500 9,900 2.9 2.8 2,800 10,900 3.2 0.092 0.059

FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE


1-phase, 220-240 V/220 V, 50/60 Hz 3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.092 0.059 4,000 16,000 4.7 4.5 4,300 17,100 5.0 0.130 0.097 5,000 19,800 5.8 5.6 5,400 21,500 6.3 0.130 0.097 6,300 24,900 7.3 7.1 6,900 27,300 8.0 0.161 0.126 8,000 31,700 9.3 9.0 8,600 34,100 10.0 0.209 0.176 12,500 49,500 14.5 14.0 13,800 54,600 16.0 0.256 0.223

kcal/h Heating capacity Cooling Heating kW Btu/h kW Power consumption Casing Airflow rate (H/L) Sound level (H/L) 240 V /s m3/min dB(A) mm kg

Galvanised steel plate 116/83 7/5 34/29 305X775X600 26.0 6.4 mm 12.7 150/108 9/6.5 36/30 305X775X600 26.0 6.4 12.7 150/108 9/6.5 36/30 305X775X600 26.0 6.4 12.7 200/150 12/9 37/32 305X990X600 31.0 6.4 12.7 200/150 12/9 37/32 305X990X600 32.0 6.4 12.7 275/216 16.5/13 39/34 433/350 26/21 41/36 550/416 33/25 46/40

Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain Model Panel (Option) Colour Dimensions (HXWXD) Weight

305X1,175X600 305X1,665X600 305X1,665X600 35.0 9.5 15.9 47.0 9.5 15.9 48.0 9.5 15.9

VP25 (External Dia, 32/Internal Dia, 25) BYBC32G-W1 BYBC50G-W1 White (10Y9/0.5) mm kg 53X1,030X680 53X1,030X680 53X1,030X680 53X1,245X680 53X1,245X680 53X1,430X680 53X1,920X680 53X1,920X680 8.0 8.0 8.0 8.5 8.5 9.5 12.0 12.0 BYBC63G-W1 BYBC125G-W1

Ceiling Mounted Cassette Corner Type


MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2) 2,500 9,900 2.9 2.8 2,800 10,900 3.2 0.066 0.046 183/150 11/9 40/35 215X1,110X710 31.0 6.4 mm 12.7

FXKQ25MAVE

FXKQ32MAVE
3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.066 0.046 183/150 11/9 40/35 215X1,110X710 31.0 6.4 12.7 BYK45FJW1

FXKQ40MAVE
4,000 16,000 4.7 4.5 4,300 17,100 5.0 0.076 0.056 216/166 13/10 42/36 215X1,110X710 31.0 6.4 12.7

FXKQ63MAVE
6,300 24,900 7.3 7.1 6,900 27,300 8.0 0.105 0.085 300/250 18/15 44/39 215X1,310X710 34.0 9.5 15.9 BYK71FJW1

1-phase, 220-240 V/220 V, 50/60 Hz

kcal/h Heating capacity Cooling Heating kW Btu/h kW Power consumption Casing Airflow rate (H/L) Sound level (H/L) Machine weight Liquid (Flare) Piping Gas (Flare) connections Drain Model Panel (Option) Colour Dimensions (HXWXD) Weight mm kg 240 V /s m3/min dB(A) mm kg

Galvanised steel plate

Dimensions (HXWXD)

VP25 (External Dia, 32/Internal Dia, 25) White (10Y9/0.5) 70X1,240X800 8.5 70X1,240X800 8.5 70X1,240X800 8.5 70X1,440X800 9.5

Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35.0CDB. (*2) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.) Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. (FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

28

SPECIFICATIONS
INDOOR UNITS
Slim Ceiling Mounted Duct Type (700 mm width type)
MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2) 2,000 7,800 2.3 2.2 2,200 8,500 2.5 0.086 0.067

FXDQ20PBVE

FXDQ25PBVE
1-phase, 220-240 V/220 V, 50/60 Hz 2,500 9,900 2.9 2.8 2,800 10,900 3.2 0.086 0.067 Galvanised steel plate

FXDQ32PBVE
3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.089 0.070

kcal/h Heating capacity Btu/h kW Power consumption Casing Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) 2 3 Sound power (HH) Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain mm /s m3/min Pa dB(A) dB(A) mm kg Cooling Heating kW

133/120/106 8.0/7.2/6.4

133/120/106 8.0/7.2/6.4 30-10 1

133/120/106 8.0/7.2/6.4

33/31/29 51 200X700X620 23.0 6.4 12.7

33/31/29 51 200X700X620 23.0 6.4 12.7 VP20 (External Dia, 26/Internal Dia, 20)

33/31/29 51 200X700X620 23.0 6.4 12.7

Slim Ceiling Mounted Duct Type (900/1,100 mm width type)


MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2) 4,000 16,000 4.7 4.5 4,300 17,100 5.0 0.160 0.147

FXDQ40NBVE

FXDQ50NBVE
1-phase, 220-240 V/220 V, 50/60 Hz 5,000 19,800 5.8 5.6 5,400 21,500 6.3 0.165 0.152 Galvanised steel plate

FXDQ63NBVE
6,300 24,900 7.3 7.1 6,900 27,300 8.0 0.181 0.168

kcal/h Heating capacity Btu/h kW Power consumption Casing Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) 2 3 Sound power (HH) Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain mm /s m3/min Pa dB(A) dB(A) mm kg Cooling Heating kW

175/158/141 10.5/9.5/8.5

208/183/166 12.5/11.0/10.0 44-15 1

275/241/216 16.5/14.5/13.0

34/32/30 52 200X900X620 27.0 6.4 12.7

35/33/31 53 200X900X620 28.0 6.4 12.7 VP20 (External Dia, 26/Internal Dia, 20)

36/34/32 54 200X1,100X620 31.0 9.5 15.9

Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35.0CDB. (*2) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1: External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard".(Factory setting is 10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.) 2: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). 3: Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

29

INDOOR UNITS
Ceiling Mounted Built-in Type
MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2) 2,000 7,900 2.3 2.2 2,200 8,500 2.5 0.089 0.089 150/112 9/6.72 41/33.5 58/50.5 30 6.4 mm 12.7 2,500 9,900 2.9 2.8 2,800 10,900 3.2 0.089 0.089 150/112 9/6.72 41/33.5 58/50.5 30 6.4 12.7 3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.096 0.096 158/112

FXSYQ20MVE FXSYQ25MVE FXSYQ32MVE FXSYQ40MVE FXSYQ50MVE FXSYQ63MVE FXSYQ80MVE FXSYQ100MVE FXSYQ125MVE


1-phase, 220-240 V, 50 Hz 4,000 16,000 4.7 4.5 4,300 17,100 5.0 0.106 0.106 191/143 5,000 19,800 5.8 5.6 5,400 21,500 6.3 0.145 0.145 250/190 6,300 24,900 7.3 7.1 6,900 27,300 8.0 0.178 0.178 350/235 21/14.1 45/38.5 62/55.5 44 9.5 15.9 8,000 31,700 9.3 9.0 8,600 34,100 10.0 0.304 0.304 450/355 27/21.3 48/43 65.5/60 57 9.5 15.9 10,000 39,600 11.6 11.2 10,800 42,700 12.5 0.309 0.309 466/370 28/22.2 48/43 65.5/60 57 9.5 15.9 12,500 49,500 14.5 14.0 13,800 54,600 16.0 0.366 0.366 633/457 38/27.42 49/41.5 66/59 57 9.5 15.9

kcal/h Heating capacity


Cooling Heating

Btu/h kW

Power consumption

kW

Casing Airflow rate (H/L) External static pressure Sound level (H/L) 230 V Sound power (H/L) Machine weight Piping connections Gas (Flare) Drain Model Panel (Option) Colour Dimensions (HXWXD) Weight mm kg
3.0 3.0 3.0

Galvanised steel plate /s m3/min Pa dB(A) dB(A) mm kg 9.5/6.72 11.5/8.58 15/11.4 41/33.5 58/50.5 30 6.4 12.7 41/34.5 58/51.5 34 6.4 12.7 43/37 60/54 35 6.4 12.7

98-65-33 1 98-65-33 1 88-57-27 1 96-65-57 1 86-58-43 1 115-84-52 1 140-122-61 1 138-118-53 1 98-58 2

230 V

Dimensions (HXWXD) Liquid (Flare)

300X550X800 300X550X800 300X550X800 300X700X800 300X700X800 300X1,000X800 300X1,400X800 300X1,400X800 300X1,400X800

VP25 (External Dia, 32/Internal Dia, 25) BYBS32DJW1 BYBS32DJW1 BYBS32DJW1 BYBS45DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 BYBS125DJW1 BYBS125DJW1 White (10Y9/0.5) 55X650X500 55X650X500 55X650X500 55X800X500 55X800X500 55X1,100X500 55X1,500X500 55X1,500X500 55X1,500X500
3.5 3.5 4.5 6.5 6.5 6.5

Ceiling Concealed (Duct) Type


MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2) kcal/h Heating capacity Btu/h kW Power consumption Casing Airflow rate (H) External static pressure (H) Sound level (H) 240 V Dimensions (HXWXD) Machine weight Liquid (Flare) Piping Gas (Flare) connections Drain mm /s m /min
3

FXDYQ80MAV1 FXDYQ100MAV1 FXDYQ125MAV1 FXDYQ145MAV1


1-phase, 220 - 240 V, 50 Hz 8,000 31,700 9.3 8.8 8,480 33,800 9.9 0.415 0.415 10,000 39,600 11.6 11.2 10,800 42,700 12.5 0.700 0.700 12,500 49,500 14.5 13.9 13,800 54,600 16.0 0.780 0.780 14,500 57,600 16.9 16.0 15,800 62,800 18.4 0.880 0.880

Cooling Heating

kW

Galvanised steel plate 510 30.6 120 3 45 360X1168X869 50 9.5 15.9 778 46.7 120 3 46 360X1478X899 60 9.5 15.9 852 51.1 120 3 48 360X1478X899 65 9.5 15.9 957 57.4 120 3 51 360X1478X899 66 9.5 15.9

Pa dB(A) mm kg

VP25 (External Dia, 32/Internal Dia, 25)

Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35.0CDB. (*2) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "High static pressure-Standard-Low static pressure". 2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "High static pressure-Standard". 3: External static pressure is changeable to change over the connectors inside electrical box (High static pressure-Standard static pressure). The data above is for high static pressure setting. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.) For FXDYQ models, an air filter is not a standard accessory. A suitable locally obtained filter must be installed in the return air duct. Sound level: (FXSYQ) Anechoic chamber conversion value, based on Australian Standard 1217.6-1985. Measurement is based on bottom-return air entry. (FXDYQ) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

30

SPECIFICATIONS
INDOOR UNITS
Ceiling Mounted Duct Type
MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2) 2,000 7,800 2.3 2.2 2,200 8,500 2.5 0.081 0.069

FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE


1-phase, 220-240 V/220 V, 50/60 Hz 2,500 9,900 2.9 2.8 2,800 10,900 3.2 0.081 0.069 3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.085 0.073 Galvanised steel plate /s m3/min Pa dB(A) dB(A) mm kg 150/125/108 9/7.5/6.5
30-100
1

4,000 16,000 4.7 4.5 4,300 17,100 5.0 0.194 0.182

5,000 19,800 5.8 5.6 5,400 21,500 6.3 0.215 0.203

kcal/h Heating capacity Btu/h kW Power consumption Casing Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) Sound power (H) Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain mm Cooling Heating kW

150/125/108 9/7.5/6.5
30-100
1

158/133/116 9.5/8/7
30-100
1

267/216/183 16/13/11
30-160
1

300/275/250 18/16.5/15
50-200
1

33/31/29 51 300X550X700 25.0 6.4 12.7

33/31/29 51 300X550X700 25.0 6.4 12.7

34/32/30 52 300X550X700 25.0 6.4 12.7

39/37/35 57 300X700X700 28.0 6.4 12.7

41/39/37 59 300X1,000X700 36.0 6.4 12.7

VP25 (External Dia, 32/Internal Dia, 25)

MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2)

FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE


1-phase, 220-240 V/220 V, 50/60 Hz 6,300 24,900 7.3 7.1 6,900 27,300 8.0 0.230 0.218 8,000 31,700 9.3 9.0 8,600 34,100 10.0 0.298 0.286 10,000 39,600 11.6 11.2 10,800 42,700 12.5 0.376 0.364 Galvanised steel plate /s m3/min Pa dB(A) dB(A) mm kg 325/292/267 19.5/17.5/16
50-200
1

12,500 49,500 14.5 14.0 13,800 54,600 16.0 0.461 0.449

14,300 57,000 16.7 16.0 15,500 61,400 18.0 0.461 0.449

kcal/h Heating capacity Btu/h kW Power consumption Casing Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) Sound power (H) Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain mm Cooling Heating kW

417/375/333 25/22.5/20
50-200
1

533/450/383 32/27/23
50-200
1

650/550/466 39/33/28
50-200
1

766/649/533 46/39/32
50-140
1

42/40/38 60 300X1,000X700 36.0 9.5 15.9

43/41/39 61 300X1,000X700 36.0 9.5 15.9

43/41/39 61 300X1,400X700 46.0 9.5 15.9

44/42/40 62 300X1,400X700 46.0 9.5 15.9

46/45/43 64 300X1,400X700 47.0 9.5 15.9

VP25 (External Dia, 32/Internal Dia, 25)

Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35.0CDB. (*2) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

31

INDOOR UNITS
Ceiling Suspended Type
MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2) 3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.111 0.111

FXHQ32MAVE

FXHQ63MAVE
1-phase, 220-240 V/220 V, 50/60 Hz 6,300 24,900 7.3 7.1 6,900 27,300 8.0 0.115 0.115 White (10Y9/0.5)

FXHQ100MAVE
10,000 39,600 11.6 11.2 10,800 42,700 12.5 0.135 0.135

kcal/h Heating capacity Btu/h kW Power consumption Casing Airflow rate (H/L) Sound level (H/L) Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain mm /s m3/min dB(A) mm kg Cooling Heating kW

200/166 12 /10 36/31 195X960X680 24.0 6.4 12.7

291/233 17.5 /14 39/34 195X1,160X680 28.0 9.5 15.9 VP20 (External Dia, 26/Internal Dia, 20)

416/325 25/19.5 45/37 195X1,400X680 33.0 9.5 15.9

Wall Mounted Type


MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW (*1) (*2) 2,000 7,800 2.3 2.2 2,200 8,500 2.5 0.016 0.024 2,500 9,900 2.9 2.8 2,800 10,900 3.2 0.022 0.027

FXAQ20MAVE FXAQ25MAVE FXAQ32MAVE FXAQ40MAVE FXAQ50MAVE FXAQ63MAVE


1-phase, 220-240 V/220 V, 50/60 Hz 3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.027 0.032 4,000 16,000 4.7 4.5 4,300 17,100 5.0 0.020 0.020 5,000 19,800 5.8 5.6 5,400 21,500 6.3 0.027 0.032 6,300 24,900 7.3 7.1 6,900 27,300 8.0 0.050 0.060

kcal/h Heating capacity Btu/h kW Power consumption Casing Airflow rate (H/L) Sound level (H/L) Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain mm /s m3/min dB(A) mm kg Cooling Heating kW

White (3.0Y8.5/0.5) 125/75 7.5/4.5 35/29 290X795 X230 11.0 6.4 12.7 133/83 8/5 36/29 290X795 X230 11.0 6.4 12.7 150/91 9/5.5 37/29 290X795 X230 11.0 6.4 12.7 200/150 12/9 39/34 290X1,050 X230 14.0 6.4 12.7 250/200 15/12 42/36 290X1,050 X230 14.0 6.4 12.7 316/233 19/14 46/39 290X1,050 X230 14.0 9.5 15.9

VP13 (External Dia, 18/Internal Dia, 13)

Note : Specifications are based on the following conditions ; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35.0CDB. (*2) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.) Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

32

SPECIFICATIONS
INDOOR UNITS
Floor Standing Type/Concealed Floor Standing Type
MODEL
Power supply kcal/h(*1) 2,000 7,800 2.3 2.2 2,200 8,500 2.5 0.049 0.049 2,500 9,900 2.9 2.8 2,800 10,900 3.2 0.049 0.049

FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE
1-phase, 220-240 V/220 V, 50/60 Hz 3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.090 0.090 4,000 16,000 4.7 4.5 4,300 17,100 5.0 0.090 0.090 5,000 19,800 5.8 5.6 5,400 21,500 6.3 0.110 0.110 6,300 24,900 7.3 7.1 6,900 27,300 8.0 0.110 0.110

FXLQ

Cooling capacity

Btu/h(*1) kW (*1) (*2)

kcal/h Heating capacity Btu/h kW

FXNQ

Power consumption Casing Airflow rate (H/L)

Cooling Heating

kW

FXLQ:Ivory white (5Y7.5/1) / FXNQ:Galvanised steel plate /s m /min


3

116/100 7/6 37/34 600X1,000X222 610X930X220 25.0 19.0 6.4

116/100 7/6 37/34 600X1,000X222 610X930X220 25.0 19.0 6.4 12.7

133/100 8/6 37/34 600X1,140X222 610X1,070X220 30.0 23.0 6.4 12.7

183/141 11/8.5 40/35 600X1,140X222 610X1,070X220 30.0 23.0 6.4 12.7 21O.D.

233/183 14/11 41/36 600X1,420X222 610X1,350X220 36.0 27.0 6.4 12.7

266/200 16/12 42/37 600X1,420X222 610X1,350X220 36.0 27.0 9.5 15.9

Sound level (H/L) 240 V Dimensions (HXWXD) Machine weight FXLQ FXNQ FXLQ FXNQ Liquid (Flare) Piping connections Gas (Flare) Drain

dB(A) mm

kg

mm

12.7

Connection unit series indoor units


* A type of BEV unit is necessary for each Connection unit series indoor unit. Refer to the Engineering Data for details. * If indoor units from the Connection unit series are connected within a single refrigerant system to indoor units from any other series, cooling/heating switchover will not be possible using the remote controller of the Connection unit series indoor units. However, if the remote controller of an indoor unit from the other series is set as a master remote controller, cooling/heating switchover will be possible. * If all indoor units are from the Connection unit series, an outdoor unit Cool/Heat selector will be needed to enable cooling/heating switchover. * Group control between Connection Unit series equipment within one system is possible. However, group control with the other VRV indoor units is not possible.

Ceiling Suspended Cassette Type


MODEL
Power supply Kcal/h(*1) Cooling capacity Btu/h(*1) (*1) kW (*2) 7,100 28,300 8.3 8.0 7,700 30,700 9.0 0.189 0.169

Indoor unit Connection unit

FXUQ71MAV1 BEVQ71MAVE

FXUQ100MAV1 BEVQ100MAVE
1-phase, 220-240 V, 50 Hz 10,000 39,600 11.6 11.2 10,800 42,700 12.5 0.298 0.278 White(10Y9/0.5)

FXUQ125MAV1 BEVQ125MAVE
12,500 49,500 14.5 14.0 12,000 47,800 14.0 0.298 0.278

Kcal/h Heating capacity (Max.) Btu/h kW Power consumption Casing Indoor unit Airflow rate (H/L) Sound level (H/L) 230 V /s m3/min dB(A) dB(A) mm kg Liquid Piping connections Gas Drain mm Cooling Heating kW

316/233 19/14 40/35 56 165X895X895 25

483/350 29/21 43/38 59 230X895X895 31 9.5 (Flare) 15.9 (Flare) VP 20 (External Dia. 26/Internal Dia. 20)

533/383 32/23 44/39 60 230X895X895 31

Sound power (H) Dimensions (HXWXD) Machine weight

33

Note : Specifications are based on the following conditions ; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35.0CDB.(*2) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.) Sound level: (FXLQ-MA,FXNQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m. (FXUQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m below the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

OUTDOOR UNITS
Heat Pump
MODEL
Power supply Kcal/h Cooling capacity Btu/h kW Kcal/h Heating capacity Cooling Heating Btu/h kW Power consumption Capacity control Casing colour Compressor Airflow rate Dimensions (H x W x D) Machine weight Sound level (Cooling/Heating) Sound power Operation range Refrigerant Piping connections Cooling Heating Type Charge Liquid Gas kg mm 15.9 (Flare) Type Motor output kW /s m3/min mm kg dB(A) dB(A) CDB CWB 50/52 68 2.5 kW % 9,600 38,200 11.2 10,800 42,700 12.5 2.95 3.27 RXYMQ4PV4A RXYMQ5PV4A 1-phase, 230240 V, 50 Hz 12,000 47,800 14.0 13,800 54,600 16.0 3.97 4.09 24 to 100 Ivory white (5Y7.5/1) Hermetically sealed scroll type 3.0 1,766 106 1,345 x 900 x 320 125 51/53 69 -5 to 46 -20 to 15.5 R-410A 4.0 9.5 (Flare) 19.1 (Brazing) 53/55 71 3.5 RXYMQ6PV4A 13,300 52,900 15.5 15,500 61,400 18.0 4.44 4.82

Note: Specifications are based on the following conditions; Cooling: Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Equivalent piping length: 7.5 m Level difference: 0 m Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. Refrigerant charge is required.

34

OPTION LIST
INDOOR UNITS
Ceiling Mounted Cassette (Round Flow) Type
No.
1 2 3

Item

Type FXFQ25P FXFQ32P FXFQ40P FXFQ50P FXFQ63P FXFQ80P FXFQ100P FXFQ125P


BYCP125K-W1 KDBH55K160F KDBP55H160FA KAFP556H80 KAFP557H80 KAFP552H80 KAFP553H80 KDDFP55H160 KAFP551K160 KAFP55H160 KAFP55H160H KDDP55K160 KDDP55K160K KDDP55X160 KDJP55H80 KKSJ55K160 KDTP55K80

5 6 7 8

Decoration Panel Sealing member of air discharge outlet Panel spacer High efficiency filter unit 65% High efficiency filter unit 90% Replacement high efficiency filter 65% Replacement high efficiency filter 90% Filter related Filter chamber Long life replacement filter Non-woven type Ultra long-life filter Replacement ultra long-life filter Without T shape and fan Chamber type With T shape without fan Fresh air intake kit Direct installation type Branch duct chamber Chamber connection kit Insulation kit for high humidity

KAFP556H160 KAFP557H160 KAFP552H160 KAFP553H160

KDJP55H160 KDTP55K160

Ceiling Mounted Cassette (Compact Multi Flow) Type


No.
1 2 3 4 5

Item

Type

FXZQ20M

FXZQ25M

FXZQ32M
BYFQ60B8W1 KDBHQ44B60 KDBQ44B60A KAFQ441B60 KDDQ44X60

FXZQ40M

FXZQ50M

Decoration panel Sealing member of air discharge outlet Panel spacer Replacement long-life filter Fresh air intake kit Direct installation type

Ceiling Mounted Cassette (Double Flow) Type


No.
1

Type FXCQ20M Item


Decoration Panel High efficiency filter 65% 1 High efficiency filter 90% 1 Filter chamber bottom suction Long life replacement filter

FXCQ25M FXCQ32M

FXCQ40M

FXCQ50M

FXCQ63M
BYBC63G-W1 KAFJ532G80 KAFJ533G80 KDDFJ53G80 KAFJ531G80

FXCQ80M FXCQ125M
BYBC125G-W1 KAFJ532G160 KAFJ533G160 KDDFJ53G160 KAFJ531G160

2
Note:

Filter related

BYBC32G-W1 KAFJ532G36 KAFJ533G36 KDDFJ53G36 KAFJ531G36

BYBC50G-W1 KAFJ532G56 KAFJ533G56 KDDFJ53G56 KAFJ531G56

1 Filter chamber is required if installing high efficiency filter.

Ceiling Mounted Cassette Corner Type


No.
1

Item
Panel related Air inlet and air discharge outlet related

Type
Decoration Panel Panel Spacer Long life replacement filter Air discharge grille Air discharge blind panel Flexible duct (with shutter)

FXKQ25MA

FXKQ32MA
BYK45FJW1 KPBJ52F56W KAFJ521F56 K-HV7AW KDBJ52F56W KFDJ52FA56

FXKQ40MA

FXKQ63MA
BYK71FJW1 KPBJ52F80W KAFJ521F80 K-HV9AW KDBJ52F80W KFDJ52FA80

Slim Ceiling Mounted Duct Type (700 mm width type)


No.
1

Type Item
Insulation kit for high humidity

FXDQ20PB

FXDQ25PB
KDT25N32

FXDQ32PB

Slim Ceiling Mounted Duct Type (900/1,100 mm width type)


No.
1

Type Item
Insulation kit for high humidity

FXDQ40NB
KDT25N50

FXDQ50NB

FXDQ63NB
KDT25N63

35

INDOOR UNITS
Ceiling Mounted Built-in Type
No.
1

Type Item
Panel related Decoration Panel Access panel High efficiency filter 65% 1 High efficiency filter 90% 1 Long life replacement filter Filter chamber for bottom suction Air suction canvas Screening door

FXSYQ20M FXSYQ25M FXSYQ32M


BYBS32DJW1 KTBJ25K36W KAFJ252L36 KAFJ253L36 KAFJ251K36 KAJ25L36D KSA-25K36 KBBJ25K36

FXSYQ40M FXSYQ50M
BYBS45DJW1 KTBJ25K56W KAFJ252L56 KAFJ253L56 KAFJ251K56 KAJ25L56D KSA-25K56 KBBJ25K56

FXSYQ63M
BYBS71DJW1 KTBJ25K80W KAFJ252L80 KAFJ253L80 KAFJ251K80 KAJ25L80D KSA-25K80 KBBJ25K80

FXSYQ80M FXSYQ100M FXSYQ125M


BYBS125DJW1 KTBJ25K160W KAFJ252L160 KAFJ253L160 KAFJ251K160 KAJ25L160D KSA-25K160 KBBJ25K160

Filter related

3
Note:

Air inlet related

1 If installing a high efficiency filter in the Ceiling Mounted Built-in type, a filter chamber for bottom suction is required.

Ceiling Concealed (Duct) Type


No.
1

Item
Run/fault status PCB

Type

FXDYQ80MA

FXDYQ100MA

FXDYQ125MA

FXDYQ145MA

KRP1B5X

Ceiling Mounted Duct Type


No. Item
High efficiency filter Filter chamber Long life replacement filter Long life filter chamber kit Service panel Air discharge adaptor

Type
65% 90%

FXMQ20P FXMQ25P FXMQ32P


KAF372AA36 KAF373AA36 KDDF37AA36 KAF371AA36 KAF375AA36 KTBJ25K36W KTBJ25K36F KTBJ25K36T KDAJ25K36A

FXMQ40P
KAF372AA56 KAF373AA56 KDDF37AA56 KAF371AA56 KAF375AA56 KTBJ25K56W KTBJ25K56F KTBJ25K56T KDAJ25K56A

FXMQ50P FXMQ63P FXMQ80P


KAF372AA80 KAF373AA80 KDDF37AA80 KAF371AA80 KAF375AA80 KTBJ25K80W KTBJ25K80F KTBJ25K80T KDAJ25K71A

FXMQ100P FXMQ125P FXMQ140P


KAF372AA160 KAF373AA160 KDDF37AA160 KAF371AA160 KAF375AA160 KTBJ25K160W KTBJ25K160F KTBJ25K160T KDAJ25K140A

1 2 3 4 5 6

Ceiling Suspended Type


No.
1 2 3

Item
Drain pump kit Replacement long-life filter (Resin net) L-type piping kit (for upward direction)

Type

FXHQ32MA
KDU50M60VE KAFJ501D56 KHFP5M35

FXHQ63MA
KAFJ501D80 KHFP5M63

FXHQ100MA
KDU50M125VE KAFJ501D112

Wall Mounted Type


No.
1

Item
Drain pump kit

Type FXAQ20MA

FXAQ25MA

FXAQ32MA

FXAQ40MA

FXAQ50MA

FXAQ63MA

K-KDU572EVE

Floor Standing Type


No.
1

Item
Long life replacement filter

Type FXLQ20MA FXLQ25MA FXLQ32MA FXLQ40MA FXLQ50MA FXLQ63MA


KAFJ361K28 KAFJ361K45 KAFJ361K71

36

OPTION LIST
INDOOR UNITS
Concealed Floor Standing Type
No.
1

Item
Long life replacement filter

Type FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA


KAFJ361K28 KAFJ361K45 KAFJ361K71

Ceiling Suspended Cassette Type


No.
1 2 3 4 5

Item
Replacement long-life filter Sealing member of air discharge outlet Decoration panel for air discharge Vertical flap kit L-shape piping kit
(*1)

Type

FXUQ71MA
KDBHJ49F80 KDBTJ49F80 KDGJ49F80

FXUQ100MA
KAFJ495F140 KDBHJ49F140 KDBTJ49F140 KDGJ49F140 KHFP49M140

FXUQ125MA

Note: (*1): This option is necessary for setting up 2-way (opposing directional) airflow when the air conditioner is installed.

OUTDOOR UNITS
Heat Pump
No.
1 1-1 2 3 4 5 6

Item
Cool/Heat Selector Fixing Box REFNET Header REFNET Joint

Type

RXYMQ4PV4A

RXYMQ5PV4A
KRC19-26A KJB111A KHRP26M22H (Max. 4 branch) KHRP26M33H (Max. 8 branch) KHRP26A22T KKPJ5F180 KPT-60B160 K-KYZP15C

RXYMQ6PV4A

Central drain plug Fixture for preventing overturning Wire fixture for preventing overturning

CONTROL SYSTEMS
Operation Control System Optional Accessories
No.
1 2 3 4 5 6-1 6-2 7 8 9 10

Type Item
Remote controller Wireless Wired

FXFQ-P

FXZQ-M

FXCQ-M FXKQ-MA FXDQ-PB FXSYQ-M FXDYQ-MA FXMQ-P FXHQ-MA FXAQ-MA FXLQ-MA FXUQ-MA FXDQ-NB FXNQ-MA
BRC4C61 BRC4C65 BRC4C62 BRC4C62 BRC4C65 BRC7EA63W BRC7EA618 BRC4C62 BRC7CA528W BRC1C62 BRC1D61 BRC2C51 BRC3A61 KRP1B61 KRP2A61 KRP1B61 KRP2A61 KRP1BA56 KRP1B61 KRP2A53 KRP2A61 KRP1B61 KRP2A61 KRP1C64 KRP2A61 KRP4AA51 KRCS01-4B
Note 5

BRC7F634F BRC7E530W BRC7C62

Wired remote controller with weekly schedule timer Simplified remote controller (Exposed type) Remote controller for hotel use (Concealed type) Adaptor for wiring Wiring adaptor for electrical appendices (1) Wiring adaptor for electrical appendices (2) Remote sensor (for indoor temperature) Installation box for adaptor PCB External control adaptor for outdoor unit Adaptor for multi tenant
.

KRP1B3 KRP2A62 KRP4AA52 KRP2A61

BRC2C51 BRC3A61 KRP1B61 KRP2A61

KRP2A62 KRP4AA53

KRP1C63 KRP2A62 KRP4AA53 KRCS01-4B


Note 2,3

KRP1BA57 KRP2A62 KRP4AA53

KRP4AA51 KRP4AA51

KRP4A54 KRP4AA51 KRP4AA51

KRP4AA51 KRP4AA51 KRCS01-1B

KRCS01-1B
Note 4,6 Note 2,3

KRP1H98 KRP1BA101 KRP1B96 DTA104A62

Note 4,6

KRP1BA101 KRP4A91 DTA104A53 DTA104A61

Note 2,3

KRP4A96 DTA104A61

Note 3

KRP1CA93 DTA104A62

Note 2,3

KRP4A93 DTA114A61

KRP1B97

DTA104A61 DTA104A61

DTA104A61 DTA104A61

Note: 1. Installation box is necessary for each adaptor marked 2. Up to 2 adaptors can be fixed for each installation box.

3. Only one installation box can be installed for each indoor unit. 4. Up to 2 installation boxes can be installed for each indoor unit.

5. Installation box 6. Installation box

is necessary for second adaptor. is necessary for each adaptor.

37

CONTROL SYSTEMS
System Configuration
No.
1 2 2-1 3 3-1 3-2 4 5 6 7

Item
Residential central remote controller Central remote controller Electrical box with earth terminal (3 blocks) Unified ON/OFF controller Electrical box with earth terminal (2 blocks) Noise filter (for electromagnetic interface use only) Schedule timer Interface adaptor for SkyAir-series Central control adaptor kit
For SkyAir, FD(Y)M-FA, FDY-KA FDYB-KA, FVY(P)J-A, FXUQ-MA For UAT(Y)-K(A),FD-K

Model No.
Note 3

Function
Up to 16 groups of indoor units (128 units) can be easily controlled using the large LCD panel. ON/OFF, temperature settings and scheduling can be controlled individually for indoor units. Up to 64 groups of indoor units(128 units) can be connected, and ON/OFF, temperature setting and monitoring can be accomplished individually or simultaneously. Connectable up to 2 controllers in one system.

DCS303A51
Note 2

DCS302CA61 KJB311AA
Note 2

DCS301BA61 KJB212AA KEK26-1A


Note 2

Up to 16 groups of indoor units(128 units) can be turned, ON/OFF individually or simultaneously, and operation and malfunction can be displayed. Can be used in combination with up to 8 controllers.

DST301BA61 DTA102A52 DTA107A55 DTA103A51

Programmed time weekly schedule can be controlled by unified control for up to 64 groups of indoor units (128 units). Can turn units ON/OFF twice per day.

Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET communication system adopted for the VRV System.
* To use any of the above optional controllers, an appropriate adaptor must be installed on the product unit to be controlled.

Wiring adaptor for other air-conditioner D -NET

Up to 1024 units can be centrally controlled in 64 different groups. DTA109A51 Wiring restrictions (max. length: 1,000m, total wiring length: 2,000m, max. number of branches: 16) apply to each adaptor. Fixing plate for DTA109A51

Expander Adaptor Mounting plate

8-1

KRP4A92

Notes: 1. Installation box for adaptor must be obtained locally. 2. For FXUQ-MAV1, an interface adaptor (DTA102A52) for the SkyAir series is necessary. 3. For residential use only. Cannot be used with other centralised control equipment.

Building Management System


No.
1 1-1 1-2 1-3 1-1 1-4 intelligent Touch Controller Basic Option

Item
Hardware intelligent Touch Controller Hardware DIII-NET plus adaptor Software PPD Web 128 units

Model No.
DCS601C51 DCS601A52 DCS002C51 DCS004A51 KJB411AA DAM602B52 DAM602B51 DAM602B51x2 DAM602B51x3 DAM602B51x4 DAM002A51 DAM004A51 DAM003A51 DAM101A51 DEC101A51 DEC102A51 Power Proportional Distribution function 256 units 512 units 768 units 1024 units PPD

Function
Air-Conditioning management system that can be controlled by a compact all-in-one unit. Additional 64 groups (10 outdoor units) is possible. PPD: Power Proportional Distribution function Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC. Wall embedded switch box.

Electrical box with earth terminal (4 blocks)

Basic

Number of Hardware units to be connected

Air conditioner management system that can be controlled by personal computers.

intelligent Manager III 2-1 2-2 2-3 2-4 2-5 2-6 3 3-1 3-2 4 5 6 7 8 Optional DIII Ai unit Di unit Dio unit Option Software

Web ECONO

Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC. ECONO (Energy saving functions.) External temperature sensor for intelligent Manager III. 8 pairs based on a pair of On/Off input and abnormality input. 4 pairs based on a pair of On/Off input and abnormality input. Interface unit to allow communications between VRV and BMS. Operation and monitoring of airconditioning systems through BACnet communication.

Communication line

*1 Interface for use in BACnet

DMS502B51 DAM411B51 DAM412B51

Optional DIII board Optional Di board


*2 Interface for use in LONWORKS

Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET communication ports. Not usable independently. Expansion kit, installed on DMS502B51, to provide 16 more wattmeter pulse input points. Not usable independently. Interface unit to allow communications between VRV and BMS. Operation and monitoring of airconditioning systems through LONWORKS communication.

DMS504B51 DPF201A51 DPF201A52 DPF201A53 DCS302A52

Contact/analogue signal

Parallel interface Basic unit Temperature measurement units Temperature setting units Unification adaptor for computerised control

Enables ON/OFF command, operation and display of malfunction; can be used in combination with up to 4 units. Enables temperature measurement output for 4 groups; 0-5VDC. Enables temperature setting input for 16 groups; 0-5VDC. Interface between the central monitoring board and central control units.

Note : *1. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). *2. LONWORKS is a registered trade mark of Echelon Corporation. *3. Installation box for adaptor must be obtained locally.

38

Warning

Daikin Industries, Ltd.s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a particular country. Prior to purchase, please therefore confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, COMMERCIAL HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, MARINE TYPE CONTAINER REFRIGERATION UNITS, COMPRESSORS AND VALVES.

Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM

JMI-0107

JQA-1452

Daikin Australia Pty Limited (ISO 9001)


QEC 23256 31 May 2006

All of the Daikin Groups business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management.

Daikin Australia Pty Limited (ISO 14001)


CEM20437 13 November 2006