Penguard Clear Sealer

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Technical Data Sheet

Approved 612;4265 1,2 4265 epoxy ^(ValidationDate) 1

Penguard Clear Sealer

Product description
This is a two component transparent polyamide cured high molecular weight epoxy sealer coating. It has
excellent penetrating properties and is designed to be used as sealer coat or varnish for concrete surfaces. Can
be used as primer or finish coat in a complete system in atmospheric environments.

Typical use
Protective:
Suitable for concrete exposed to a wide range of environments.
Other

Colours
transparent

Product data
Property Test/Standard Description

Solids by volume ISO 3233 44 ± 2 %


Gloss level (GU 60 °) ISO 2813 gloss (70-85)
Flash point ISO 3679 Method 1 25 °C
Density calculated 0.97 kg/l

Region Regulation Test Standard VOC Value

US CARB(SCM)2020 / SCAQMD rule 1113 Calculated 494 g/l


Hong Kong Air Pollution Control (VOC) Regulation Calculated 494 g/l
EU European Paint Directive 2004/42/CE Calculated 494 g/l
EU IED Industrial Emission Directive 2010/75/EU Calculated 494 g/l
Korea Korea Clean Air Conservation Act Calculated 494 g/l
China GB 30981-2020 Limit of harmful GB/T 23985-2009 8.3 467 g/l
substances of industrial protective coatings

The provided data is typical for factory produced products, subject to slight variation depending on colour.
Gloss description: According to Jotun Performance Coatings' definition.

Date of issue: 8 April 2024 Page: 1/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Penguard Clear Sealer

Film thickness per coat


Typical recommended specification range

Dry film thickness 30 - 50 μm


Wet film thickness 70 - 115 μm
Theoretical spreading rate 14.7 - 8.8 m²/l

Surface preparation

Surface preparation summary table

Surface preparation

Substrate Minimum Recommended

Coated surfaces Clean, dry and undamaged compatible Clean, dry and undamaged compatible
coating coating
Concrete Low pressure water washing to a Minimum 4 weeks curing.Moisture
rough, clean, dry and laitance free content maximum 5 %.Low pressure
surface. water washing to a rough, clean, dry
and laitance free surface.

Optimum performance, including adhesion, corrosion protection, heat resistance and chemical resistance is
achieved with recommended surface preparation.

Application
Application methods
The product can be applied by

Spray: Use airless spray.


Brush: Recommended.
Roller: Recommended.

Product mixing ratio (by volume)

Penguard Clear Sealer Comp A 4 part(s)


Penguard Comp B 1 part(s)

Date of issue: 8 April 2024 Page: 2/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Penguard Clear Sealer

Thinner/Cleaning solvent
Thinner: Jotun Thinner No. 17

Guiding data for airless spray


Nozzle tip (inch/1000): 15-23
Pressure at nozzle (minimum): 150 bar/2100 psi

Drying and Curing time


Substrate temperature 10 °C 23 °C 40 °C

Surface (touch) dry 2h 1h 30 min


Walk-on-dry 14 h 6.5 h 4h
Dry to over coat, minimum 8h 4h 2h
Dried/cured for service 14 d 7d 3d

For maximum overcoating intervals, refer to the Application Guide (AG) for this product.

Drying and curing times are determined under controlled temperatures and relative humidity below 85 %, and
at average of the DFT range for the product.

Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal
tackiness.

Walk-on-dry: Minimum time before the coating can tolerate normal foot traffic without permanent marks,
imprints or other physical damage.

Dry to over coat, minimum: The recommended shortest time before the next coat can be applied.

Dried/cured for service: Minimum time before the coating can be permanently exposed to the intended
environment/medium.

Induction time and Pot life


Paint temperature 23 °C

Induction time 30 min


Pot life 8h

Heat resistance
Temperature
Continuous Peak

Dry, atmospheric 120 °C 140 °C

Peak temperature duration max. 1 hour.

Date of issue: 8 April 2024 Page: 3/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Penguard Clear Sealer

The temperatures listed relate to retention of protective properties. Aesthetic properties may suffer at these
temperatures.

Product compatibility
Depending on the actual exposure of the coating system, various primers and topcoats can be used in
combination with this product. Some examples are shown below. Contact Jotun for specific system
recommendation.
Subsequent coat: epoxy, polyurethane

Packaging (typical)
Volume Size of containers
(litres) (litres)

Penguard Clear Sealer Comp A 4/16 5/20


Penguard Comp B 1/4 1/5

The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary
due to local regulations.

Storage
The product must be stored in accordance with national regulations. Keep the containers in a dry, shaded, cool,
well-ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed.
Handle with care.

Shelf life at 23 °C
Penguard Clear Sealer Comp A 24 month(s)
Penguard Comp B 24 month(s)

In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf
life, thereafter the paint quality is subject to re-inspection.

Caution
This product is for professional use only. The applicators and operators shall be trained, experienced and have
the capability and equipment to mix/stir and apply the coatings correctly and according to Jotun's technical
documentation. Applicators and operators shall use appropriate personal protection equipment when using this
product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit
the site conditions shall be forwarded to the responsible Jotun representative for approval before commencing
the work.

Health and safety


Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do
not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable
cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

Date of issue: 8 April 2024 Page: 4/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Penguard Clear Sealer

Colour variation
When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations
from batch to batch. Such products and epoxy based products used as a finish coat may chalk when exposed to
sunlight and weathering.

Colour and gloss retention on topcoats/finish coats may vary depending on type of colour, exposure
environment such as temperature, UV intensity etc., application quality and generic type of paint. Contact your
local Jotun office for further information.

Disclaimer
The information in this document is given to the best of Jotun's knowledge, based on laboratory testing and
practical experience. Jotun's products are considered as semi-finished goods and as such, products are often
used under conditions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product
itself. Minor product variations may be implemented in order to comply with local requirements. Jotun reserves
the right to change the given data without further notice.

Users should always consult Jotun for specific guidance on the general suitability of this product for their needs
and specific application practices.

If there is any inconsistency between different language issues of this document, the English (United Kingdom)
version will prevail.

Date of issue: 8 April 2024 Page: 5/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com

You might also like