SFF-8661 (Specification For QSFP 4X Module Rev 2.4 October 3, 2017)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

PUBLISHED SFF-8661 Rev 2.

SFF specifications are available at http://www.snia.org/sff/specifications

SFF-8661

Specification for

QSFP+ 4X Module

Rev 2.4 October 3, 2017

Secretariat: SFF TA TWG

Abstract: This specification defines the mechanical specifications for the QSFP+ 4x
Module Formfactor.

The mechanical dimensioning allows backwards mechanical compatibility between QSFP+


4X modules plugged into most QSFP+ cages which have been implemented to SFF-8436.
The EMI leakage is expected to be similar to that when QSFP+ modules and cages are
mated.

Superior EMI performance can only be expected with mated combinations of modules
compliant with this specification and cages compliant with SFF-8663 or SFF-8683.

This specification provides a common reference for systems manufacturers, system


integrators, and suppliers.

This specification is made available for public review, and written comments are
solicited from readers. Comments received by the members will be considered for
inclusion in future revisions of this specification.

The description of a connector in this specification does not assure that the
specific component is actually available from connector suppliers. If such a
connector is supplied it must comply with this specification to achieve
interoperability between suppliers.

POINTS OF CONTACT:
Jay Neer Dan Gorenc Chairman SFF TA TWG
Molex, LLC. TE Connectivity Email: [email protected]
2222 Wellington Court 3101 Fulling Mill Rd
Lisle, IL 60532 Middletown, PA 17057
Ph: 561-251-8016 Ph: 717-986-3518
[email protected] [email protected]

QSFP+ 4X Module Page 1


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

Change History
December 28, 2010:
- Section 3:
o Divided Figure 3-1 into two figures (3-1 and 3-2) and updated titles
accordingly
- Section 4:
o Added "Datum Definitions" table
o Updated Figure 4-1 with the following changes:
▪ Added "Module/Plug" description to top view
▪ Added appropriate SFF document reference to each view
▪ Extended datum line through all 3 views
▪ Replaced "SEE FIGURES 12A AND 12B" WITH "EMI SOLUTION DEPENDENT"
- Section 5:
o Updated Figure 5-1 with the following changes:
▪ Added note triangle 2 to 32 MIN. dimension
▪ Added 19 MAX., 13.5 REF., 3.4 MAX. and 1.6 MAX. dimensions
o Updated Figure 5-2 with the following changes:
▪ Added "MAX." and "MIN." to 1.10 / 0.55 dimension (View K-K)
o Updated Figure 5-3 with the following changes:
▪ Replaced SFP+ PCB with QSFP+ PCB
o Updated description of Figure 5-3
- Section 6:
o Updated title (previously was Section 7)
o Replaced Table 7-1 AND 7-2 (SFP+ requirements) with Table 6-1
▪ Added text to clarify that connector is included in module
insertion/extraction

June 12, 2011:


- Global
o Removed redundant use of 25G throughout body
o All references to 25G were replaced by 32 Gb/s
o Specification Titles updated to current usage
o Added Table of Contents

January 30, 2012:


- All references to 32 Gb/s were replaced by 28 Gb/s

May 21, 2012:


- Expanded list of Industry Documents

July 7, 2012:
- Figure 5-1 was redrawn
o Note 4 was clarified
o Note 9 re higher wattage models added
o Length of transceiver outside of cage restored to the 20 Max of the MSA

Rev 1.7 (May 22, 2013):


- Corrected title (removed 'Style')

Rev 1.8 (July 29, 2013):


- Identified Datums to be corrected on Figure 4-1, Figure 5-1 and Figure 5-2

Continued on next page

QSFP+ 4X Module Page 2


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

Rev 1.9 (October 16, 2013):


- Replaced Figure 4-1
o Sidebar shows how Style A and B create a common figure
- Updated Figure 5-1
- Updated Figure 5-2
o Added Datums D and H to Detail 1
- Revised Table 5-1 (was 6-1) cage retention force from 180N to 125N

Rev 2.0 (February 21, 2014):


- Replaced reference to SFF-8436 with EIA 964 in 2-1
- Replaced figures 4-1, 5-1, 5-2 to improve quality
- Deleted two rows in Table 6-1 that did not apply to the Plug/Module

Rev 2.1 (May 25, 2014):


- Restored two rows in Table 6-1 that should not have been deleted

Rev 2.2 (August 7, 2014):


- Replaced Figure 5-2 (the view of section J-J had the radius 0.05 MIN and the
dimension 29.60 REF pointing to the wrong location).

Rev 2.3 (September 13, 2014):


- Removed references to 28 Gb/s

Rev 2.4 (October 3, 2017)


- Updated to SNIA format
- Revised abstract
- Reformatted Change History
- Fixed broken links in Foreword
- Updated applications (Section 1.1)
- Added EIA document references
- Clarified “fixed” and “free” definitions
- All references to “pluggable modules,” “plugs,” or “modules” changed to
“module;” added definition for “module”
- Minor editorial issues resolved
- Renamed Figure 3-2
- Corrected table in Figure 4-1
- Clarified chamfer/radius callout in Figure 5-2
- Updated Section 5.3 (Insertion, Extraction, and Retention Forces) to agree
with other SFF documents for QSFP

QSFP+ 4X Module Page 3


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

Foreword

The development work on this specification was done by the SNIA SFF TWG, an industry
group. Since its formation as the SFF Committee in August 1990, the membership has
included a mix of companies which are leaders across the industry.

When 2 1/2" diameter disk drives were introduced, there was no commonality on
external dimensions e.g. physical size, mounting locations, connector type,
connector location, between vendors. The SFF Committee provided a forum for system
integrators and vendors to define the form factor of disk drives.

During their definition, other activities were suggested because participants in SFF
faced more challenges than the form factors. In November 1992, the charter was
expanded to address any issues of general interest and concern to the storage
industry. The SFF Committee became a forum for resolving industry issues that are
either not addressed by the standards process or need an immediate solution.

In July 2016, the SFF Committee transitioned to SNIA (Storage Networking Industry
Association), as a TA (Technology Affiliate) TWG (Technical Work Group).

Industry consensus is not a requirement to publish a specification because it is


recognized that in an emerging product area, there is room for more than one
approach. By making the documentation on competing proposals available, an
integrator can examine the alternatives available and select the product that is
felt to be most suitable.

SFF meets during the T10 (see www.t10.org) and T11 (see www.t11.org) weeks, and
SSWGs (Specific Subject Working Groups) are held at the convenience of the
participants. Material presented to SFF becomes public domain, and there are no
restrictions on the open mailing of the presented material by Members.

Many of the specifications developed by SFF have either been incorporated into
standards or adopted as standards by ANSI, EIA, JEDEC and SAE.

For those who wish to participate in the activities of the SFF TWG, the signup for
membership can be found at:
http://www.snia.org/sff/join

The complete list of SFF Specifications which have been completed or are currently
being worked on by the SFF Committee can be found at:
https://ta.snia.org/higherlogic/ws/public/download/47/SFF-8000.TXT

If you wish to know more about the SFF TWG, the principles which guide the
activities can be found at:

https://ta.snia.org/higherlogic/ws/public/download/144/8032_028.PDF

Suggestions for improvement of this specification will be welcome, they should be


submitted to:
http://www.snia.org/feedback

QSFP+ 4X Module Page 4


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

CONTENTS

1. Scope 6
1.1 Application Specific Criteria 6
1.2 Copyright 6
1.3 Disclaimer 7

2. References 7
2.1 Industry Documents 7
2.2 Sources 7
2.3 Conventions 8
2.4 Definitions 8

3. General Description 10

4. Datums 11

5. Module Description 13
5.1 Dimensions 13
5.2 Electrical Interface 15
5.3 Insertion, Extraction, and Retention Forces 15

FIGURES
Figure 2-1 Fixed and Free Definition 8
Figure 3-1 Typical Module with Copper Cable 10
Figure 3-2 Typical Module (Without Cable) 10
Figure 4-1 Datum Definitions 11
Figure 5-1 Basic Views 13
Figure 5-2 Enlarged View of module 14
Figure 5-3 Module Electrical Interface 15

TABLES
Table 4-1 Datum Definitions 12
Table 5-1 Insertion, Extraction, and Retention Values 15

QSFP+ 4X Module Page 5


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

1. Scope
This specification defines the terminology and mechanical requirements for a QSFP+
4x module. This specification is also intended to facilitate the implementation of
the 1 x "n" ganged and the 2 x "n" stacked cage configurations based on the
mechanical form factor defined in this specification.

The need for this specification became evident when it was realized that some QSFP+
modules and cage designs do not meet the needs for the higher data rates. The QSFP+
is an improved transceiver style which has enhanced EMI characteristics when mated
with a cage designed for the module. Please note that there are additional cage
requirements specified in this document to allow proper function of the modules in
application. These improvements make this module suitable for current QSFP+
applications as well as those at higher transfer rates.

1.1 Application Specific Criteria


SAS, InfiniBand, IEEE, and Fibre Channel define respective electrical performance
requirements for the transmission of multi-gigabit signals through this interface.
When this connector is used for any of these applications, its performance shall
meet the requirements of the appropriate standard. This connector shall intermate
with previous generations of lower speed QSFP connectors.

1.2 Copyright
The SNIA hereby grants permission for individuals to use this document for personal
use only, and for corporations and other business entities to use this document for
internal use only (including internal copying, distribution, and display) provided
that:

1. Any text, diagram, chart, table, or definition reproduced shall be


reproduced in its entirety with no alteration, and,
2. Any document, printed or electronic, in which material from this document
(or any portion hereof) is reproduced shall acknowledge the SNIA copyright
on that material, and shall credit the SNIA for granting permission for its
reuse.

Other than as explicitly provided above, there may be no commercial use of this
document, or sale of any part, or this entire document, or distribution of this
document to third parties. All rights not explicitly granted are expressly reserved
to SNIA.

Permission to use this document for purposes other than those enumerated (Exception)
above may be requested by e-mailing [email protected]. Please include the
identity of the requesting individual and/or company and a brief description of the
purpose, nature, and scope of the requested use. Permission for the Exception shall
not be unreasonably withheld. It can be assumed permission is granted if the
Exception request is not acknowledged within ten (10) business days of SNIA's
receipt. Any denial of permission for the Exception shall include an explanation of
such refusal.

QSFP+ 4X Module Page 6


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

1.3 Disclaimer
The information contained in this publication is subject to change without notice.
The SNIA makes no warranty of any kind with regard to this specification, including,
but not limited to, the implied warranties of merchantability and fitness for a
particular purpose. The SNIA shall not be liable for errors contained herein or for
incidental or consequential damages in connection with the furnishing, performance,
or use of this specification.

Suggestions for revisions should be directed to http://www.snia.org/feedback/

2. References

2.1 Industry Documents


- Ethernet IEEE 802.3ba 40G
- Ethernet IEEE 802.3bj 100G
- InfiniBand IBTA QDR/FDR/EDR
- T10 SAS-2.1 (Serial Attached SCSI)
- T10 SAS-3
- T11 FC-PI-5 (Fibre Channel Physical Interface)
- T11 FC-PI-6
- EIA-964 QSFP+ 10 Gb/s 4X Pluggable Transceiver
- SFF-8024 SFF Committee Cross Reference to Industry Product Names
- SFF-8410 High Speed Serial Testing for Copper Links
- SFF-8635 QSFP+ 10 Gb/s 4X Pluggable Transceiver Solution (QSFP10)
- SFF-8662 QSFP+ 28 Gb/s 4X Connector (Style A)
- SFF-8665 QSFP+ 28 Gb/s 4X Pluggable Transceiver Solution (QSFP28)
- SFF-8672 QSFP+ 28 Gb/s 4X Connector (Style B)
- SFF-8682 QSFP+ 4X Connector
- SFF-8683 QSFP+ Cage
- SFF-8685 QSFP+ 14 Gb/s 4X Pluggable Transceiver Solution (QSFP14)
- EIA-364-1000 Environmental Test Methodology for Assessing the Performance of
Electrical Connectors and Sockets Used in Controlled Environment Applications
- EIA-364-13 Mating and Unmating Forces Test Procedure for Electrical Connectors
2.2 Sources
There are several projects active within the SFF TWG. The complete list of
specifications which have been completed or are still being worked on are listed in
https://ta.snia.org/higherlogic/ws/public/download/47/SFF-8000.TXT

Copies of ANSI standards may be purchased from the InterNational Committee for
Information Technology Standards (http://www.techstreet.com/incitsgate.tmpl).

QSFP+ 4X Module Page 7


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

2.3 Conventions
The dimensioning conventions are described in ANSI-Y14.5M, Geometric Dimensioning
and Tolerancing. All dimensions are in millimeters, which are the controlling
dimensional units (if inches are supplied, they are for guidance only).

The ISO convention of numbering is used i.e., the thousands and higher multiples are
separated by a space and a period is used as the decimal point. This is equivalent
to the English/American convention of a comma and a period.

American French ISO


0.6 0,6 0.6
1,000 1 000 1 000
1,323,462.9 1 323 462,9 1 323 462.9

2.4 Definitions
For the purpose of SFF Specifications, the following definitions apply:

Advanced grounding contacts: Connector contacts that mate first and break last and
are capable of carrying power ground return currents and performing electrostatic
discharge. Other terms sometimes used to describe these features are: grounding
pins, ESD contacts, grounding contacts, static drain, and pre-grounding contacts.

Alignment guides: Connector features that preposition insulators prior to


electrical contact. Other terms sometimes used to describe these features are: guide
pins, guide posts, blind mating features, mating features, alignment features, and
mating guides

Contact mating sequence: Order of electrical contact during mating/unmating


process. Other terms sometimes used to describe this feature are: contact
sequencing, contact positioning, make first/break last, EMLB (early make late break)
staggered contacts, and long pin / short pin.

Fixed: Adopted from EIA standard terminology as the gender that most commonly
exists on the fixed end of a connection, for example, on the board or bulkhead side.
In this specification "fixed" is specifically used to describe the mating side
gender illustrated in Figure 2-1. It is typically used to describe the gender of
the mating side of the connector that accepts its mate upon mating. Other common
terms are “receptacle,” “female,” and “socket connector.”

Free: Adopted from EIA standard terminology as the gender that most commonly exists
on the free end of a connection, for example, on the cable side. In this
specification "free" is specifically used to describe the mating side gender
illustrated in Figure 2-1. It is typically used to describe the gender of the
mating side of the connector that penetrates its mate upon mating. Other common
terms are "plug” or “module," "male," and "pin connector.”

FIGURE 2-1 FIXED AND FREE DEFINITION

QSFP+ 4X Module Page 8


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

Module: In this specification, refers to direct attach copper (DAC), direct attach
optics, and pluggable optics.

Optional: This term describes features which are not required by the SFF
Specification. However, if any feature defined by the SFF Specification is
implemented, it shall be done in the same way as defined by the Specification.
Describing a feature as optional in the text is done to assist the reader. If there
is a conflict between text and tables on a feature described as optional, the table
shall be accepted as being correct.

Surface mount: A connector design and a printed circuit board design style where
the connector termination points do not penetrate the printed circuit board and are
subsequently soldered to the printed circuit board. Other common terms are “surface
mount technology” or “SMT.”

Through hole: A connector design and a printed circuit board design style where the
connector termination points penetrates the printed circuit board and are
subsequently soldered to the printed circuit board. Other common terms are “plated
through hole” or “PTH.”

QSFP+ 4X Module Page 9


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

3. General Description
This specification defines the complete mechanical dimensions of the QSFP+ 4x
module. This module provides interoperability and EMI control for the QSFP system.

The dimensions for the module are normative.

FIGURE 3-1 TYPICAL MODULE WITH COPPER CABLE

FIGURE 3-2 TYPICAL MODULE (WITHOUT CABLE)

QSFP+ 4X Module Page 10


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

4. Datums

FIGURE 4-1 DATUM DEFINITIONS

QSFP+ 4X Module Page 11


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

TABLE 4-1 DATUM DEFINITIONS


Datum Description
A Host board top surface
B Centerline of bezel
D *Hard stop on module
E **Width of module
F Height of module housing
H Leading edge of signal contact pads on module PCB
J Top surface of module PCB
K *Host board thru hole #1 to accept connector guide post
L *Host board thru hole #2 to accept connector guide post
N *Connector alignment pin
T *Hard stop on cage
AA **Connector slot width
DD Top surface of connector backshell
*Datums D, K, L, N and T are aligned when assembled.
**Centerlines of Datums AA, E and Z are aligned on the same vertical
axis.
***All dimensions shown are in millimeters.

QSFP+ 4X Module Page 12


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

5. Module Description

5.1 Dimensions

FIGURE 5-1 BASIC VIEWS

QSFP+ 4X Module Page 13


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

0.3 MIN CHAMFER OR


RADIUS ON TOP EDGE

FIGURE 5-2 ENLARGED VIEW OF MODULE

QSFP+ 4X Module Page 14


Copyright © 2017 SNIA. All rights reserved.
PUBLISHED SFF-8661 Rev 2.4

5.2 Electrical Interface


The QSFP+ module contains a printed circuit board that mates with an appropriately
designed connector. The pads are designed for a sequence mating:
• First mate: Ground contacts
• Second mate: Power contacts
• Third Mate: Signal contacts

FIGURE 5-3 MODULE ELECTRICAL INTERFACE

Note: View is shown for reference only. See appropriate specfication for
dimensional values. Seee the appropriate standard for the pad layout and
definitions.

5.3 Insertion, Extraction, and Retention Forces

TABLE 5-1 INSERTION, EXTRACTION, AND RETENTION VALUES


Parameter Procedure Requirement1
Insertion force EIA 364-13 60N MAX
Test with connector, cage & module
(latch disengaged, without heatsink)
Extraction force EIA 364-13 30N MAX
Test with connector, cage & module
(latch disengaged, without heatsink)
Latch strength Pull to separate module from cage 125N MIN
Test with connector, cage & module
(latch engaged)
Bulk cable Pull to separate bulk cable from module 90N MIN
retention in Test with cable assembly only
module2
Module durability Test with connector, cage & module as part 50 cycles
of TS-10003 MIN
NOTES:
1. In addition to the requirements listed, all parts must be free of
visible damage after testing.
2. Does not apply to pluggable optical modules.
3. Modules may be replaced every 50 cycles.

QSFP+ 4X Module Page 15