MANNINGS TRANSFORMER Tech Spec

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

TECHNICAL

SPECIFICATION
Transformer Power Unit – (6 Output channel)
Stock Reference: 11000 for 50kVA, 11100 for 70kVA Features:
• Outputs for 60V heaters
Stork’s transformer units (Mannings model) have achieved a worldwide
• Controllers can be set to operate in °C or °F
reputation for cost effective design, quality and reliability having been
successfully operated on heat treatment projects in some of the most • Displays set point and work piece temperature
demanding climates and industrial environments and around the world, • Neon shows ‘power on’ for each output channel
for over 50 years. • Fitted with temperature controllers and energy
The unit consists of a robust, natural air cooled, 3 phase transformer regulators as standard
which is built into a compactly designed, strong, steel case which • Core winding thermostats provide automatic
together provides the unit with a long working life expectancy. protection against transformer coil overheating
Each output channel is controlled by means of an internal energy • Primary over-current protection provided by a
regulator working in parallel with a digital temperature controller. three-phase circuit breaker
Provision is also made for connection to external control from any • Multi pin output to connect to external
compatible programmer/control unit. Switching between internal programmer
(manual) control or external (automatic) control mode is made via each • Selector switches per channel to allow for internal
channel’s auto/manual selector switch. temperature control or external

Benefits:
• Rapid return on investment
• Six independent temperature controllers allow
the operator to control up to six control zones
simultaneously
• Rugged, cost effective construction
• Temperature controllers are easy to set and
operate
• Safety plugs fitted as standard to all 60V outputs

www.stork.com
50kVA Specifications 70kVA Specifications
Transformer Core
• Three Phase, Air Natural, Class ‘H’, 50kV • Three phase, forced air cooled, class H, 70kVA
• Primary winding connected in Delta • Primary winding connected in Delta
• Secondary winding connected in Star • Secondary winding connected in Star
Primary Supply
• Primary voltage: 380V, 415V, 440V • Primary voltage: 380V, 415V, 440V
• Primary current: 76A, 70A, 66A • Primary current: 106A, 97A, 92A
• Frequency: 50/60 Hz • Frequency: 50/60 Hz
Protection
• Three phase 100A circuit breaker with shunt trip • Three phase 160A circuit breaker with shunt trip
• Three primary core winding over temperature • Three primary core winding over temperature
thermostats linked to circuit breaker shunt trip thermostats linked to circuit breaker shunt trip
Secondary Outputs
• Output: 65V • Output: 65V
• 6 temperature controlled output channels• Number of • 6 temperature controlled output channels
temperature controlled output channels: 6 channels • Max load per output channel: three 60V, 2.7kW heating
• Max load per output channel: three 60V, 2.7kW heating elements
elements • Maximum current per output channel: 180A
• Maximum current per output channel: 135A • Auxiliary Output: Two 110V, 5A, 50/60Hz fused output
• Auxiliary Output: Two 110V, 5A, 50/60Hz fused output sockets
sockets
Control
• Six 110V Energy Regulators • Six 110V Energy Regulators
• Six 110V Temperature Controllers • Six 110V Temperature Controllers
• One Multi-pin socket for remote programmer • One Multi-pin socket for remote programmer
• Mode Selection: Six Auto / Manual switches • Mode Selection: Six Auto / Manual switches
• Indicators: Six 110V neon channel indicators • Indicators: Six 110V neon channel indicators
Dimensions
• Case: Robust sheet steel case complete with four • Case: Robust sheet steel case complete with four
150mm diameter wheels 150mm diameter wheels
• Weight: 302kg • Weight: 410kg
• Height: 1010mm • Height: 1010mm
• Width: 675mm • Width: 675mm
• Depth: 725mm • Depth: 725mm
• Lifting Method: Fork lift under base • Lifting Method: Fork lift under base
Mains Connection
The units are complete with 4.5m of four core primary cable
Switching
Contactorised – six off 200A, 110V a.c. solenoid contactors