Cooperheat Heat Treatment Module Tech Spec

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

TECHNICAL

SPECIFICATION
Heat Treatment Module (6 Output) Features:
• Outputs per channel for both 30V or 60V heaters
Stock Reference: 16050 for 50kVA, 16051 for 70kVA (40V and 80V output units also available)
• ‘Advantage 3’ operates in °C or °F
Compliance with international heat treatment codes and standards
requires equipment that can provide accurate control of the heat • Displays set point and work piece temperature
treatment specification parameters, including uniformity of temperature • LED shows ‘power on’ for each output channel
throughout the geometry of the work piece. As part of our commitment • Connector block provided for simple connection
to continuing innovation, Stork Cooperheat’s 50kVA and 70kVA Heat of primary supply cable
Treatment Modules include our unique ‘Advantage 3’ temperature
• Constructed from high-grade stainless steel giving
programmer/controllers which ensure the required temperature
excellent protection against corrosion, including
uniformity within each control zone. The design of our equipment is
marine offshore applications
based on over 50 years experience as a market leader in the field of heat
treatment and has been developed to meet the real needs of the heat • Core winding thermostats provide automatic
treatment engineering industry. Stork Cooperheat modules deliver :- protection against transformer coil overheating
• Value for Money • Primary over-current protection provided by a
• Versatility three-phase circuit breaker
• Ease of operation and maintenance
• Safety Benefits:
• Fitness for purpose • Rapid return on investment
• Unique ‘Advantage 3’ programmer/controller
linking features allow the operator to carry out up
to 6 heat treatment cycles simultaneously
• Each ‘Advantage 3’ communicates with other
controlling zones on the same heat treatment.
This controls and limits the differential between
each control zone within the work piece being
heated
• Simple access to transformer tapping board and
instruments for maintenance by means of a swing
hinged front panel
• Safe voltages employed. Voltage to earth from any
single output socket is 32.5V a.c.

www.stork.com
50kVA Module 70kVA Module
Transformer Core
• Three phase, forced air cooled, class H, 50kVA • Three phase, forced air cooled, class H, 70kVA
• Primary winding connected in Delta • Primary winding connected in Delta
• Secondary winding connected in Star • Secondary winding connected in Star
• Auxiliary winding: 110V a.c. 3.3kVA single phase • Auxiliary winding: 110V a.c. 3.3kVA single phase
Primary Supply
• Primary voltage: 380V, 415V, 440V • Primary voltage: 380V, 415V, 440V
• Primary current: 76A, 70A, 66A • Primary current: 106A, 97A, 92A
• Frequency: 50/60 Hz • Frequency: 50/60 Hz
Protection
• Three phase 80A circuit breaker with shunt trip • Three phase 125A circuit breaker with shunt trip
• Three primary core winding over temperature • Three primary core winding over temperature
thermostats linked to circuit breaker shunt trip thermostats linked to circuit breaker shunt trip
Secondary Outputs
• Output: 32.5V – 0V – 32.5V (for 30V and 60V heating • Output: 32.5V – 0V – 32.5V (for 30V and 60V heating
element operation) element operation)
• Auxiliary outputs: Two 110V, 10A, 50/60Hz output • Auxiliary outputs: Two 110V, 10A, 50/60Hz output
sockets sockets
• Number of temperature controlled output channels: 6 • Number of temperature controlled output channels:
channels 6 channels
• Maximum load per output channel: 8.1kW (e.g. three • Maximum load per output channel: 10.8kW (e.g. four
60V, 2.7kW heating elements) 60V, 2.7kW heating elements)
• Maximum current per output channel: 135A • Maximum current per output channel: 180A
Construction
• Case: 304 Stainless Steel case fitted with four 150mm • Case: 304 Stainless Steel case fitted with four 150mm
nylon wheels nylon wheels
• Weight: 330kg • Weight: 330kg
• Height: 110mm • Height: 110mm
• Width: 680mm • Width: 680mm
• Depth: 665mm • Depth: 665mm
Temperature Control
• Case: Temperature measurement, display and control
• Degrees Fahrenheit or Degrees Centrigrade
• Start temperature
• Temperature ramp up and down in degrees per hour
• Hold/soak temperature set point and hold/soak time period setting
Switching
• Six double pole, 180a, contractors with 110V a.c. coil

www.stork.com