How To Change RRU Loadmodule
How To Change RRU Loadmodule
How To Change RRU Loadmodule
As bellow example, RRU-2 is new RRU and the correct LoadModule is CXP9019879/2_R2F,
but it always refers to CXP9018680/2_JT002_PGUF which is old version same with RRU-
1 and RRU-3, we need to change LoadModule of RRU-2 with corresponding type. The
procedure is as bellow:
Deleting ...
===========================================================================
238 Equipment=1,AuxPlugInUnit=RRU-
2,DeviceGroup=ru,XpProgram=CXP9018680/2_JT002_PGUF >>> Mo deleted
===========================================================================
Total: 1 MOs attempted, 1 MOs deleted
YDDS> cr Equipment=1,AuxPlugInUnit=RRU-2,DeviceGroup=ru,XpProgram=CXP9019879/2_R2F
Note:At last, need to swich off RRU power then switch on.