RT Professionnal Architecture

Download as pdf or txt
Download as pdf or txt
You are on page 1of 54

WinCC RT Professional V16

Architectures
The SCADA system inside TIA Portal – Efficiency and transparency for your plant

Unrestricted © Siemens 2019 siemens.com/wincc

Unrestricted © Siemens 2019


WinCC RT Professional V16 architectures
Legend

• WinCC Runtime Professional V16


Base Packages = Base Package

• SIMATIC Information Server 2014 SP3 upd4 = IS2014

• SIMATIC Process Historian 2014 SP3 upd4 = PH2014

Unrestricted © Siemens 2019


Page 2 2/19/2020
WinCC RT Professional V16
Basic functionality

Basic functionality Description

• The WinCC OPC servers provide customer-specific OPC clients with data from the WinCC data warehouse, e.g. process values
or messages.

• The WinCC OPC UA server is installed as Windows service and started automatically.
WinCC / OPC-Server The WinCC OPC UA server supports only the communication profile
"UA-TCP UA-SC UA Binary". The used port number is adjustable.

• WinCC OPC HDA Server


The WinCC OPC HDA Server enables an OPC HDA Client to access the archived process values in the WinCC archive system.

• Runtime API describes the open programming interface of WinCC.


• Via the API functions, you use the internal functions of WinCC in your own applications and access HMI tag data or data in the
archives

Runtime API Application


• API functions are used in the following places:
• Within WinCC: In user-defined C -functions and local C-scripts.
• Outside of WinCC: In Windows applications created in the C/C++ programming language. To use Runtime API in the C# or
VB.Net programming languages, you must program a corresponding implementation.

Unrestricted © Siemens 2019


Page 3 2/19/2020
WinCC RT Professional V16
Runtime options

Runtime Options Description


WinCC Server / WinCC Client Server/client systems Server Lizenz:
6AV2107-0EB00-0BB0
Client-Lizenz:
6AV2107-0DB06-0AH0
Organization of data records for associated machines / production data
WinCC Recipes 6AV2107-0JB00-0BB0
WinCC Redundancy provides a considerable increase in the availability of WinCC and the
SIMATIC WinCC Redundancy system as a whole by operating two servers at the same time linked together. 6AV2107-0FB00-0BB0

WinCC Logging (1500/5000 Tags) Archiving of process data (including 500 archive tags) 6AV2107-0GB00-0BB0
Control and monitoring via the web (MS Internet Explorer) See WebNavigator
WinCC WebNavigator slides
Platform and browser-independent operator control and monitoring via the web (HTML5)
WebUX See WebUX slides
Monitoring and analyzing of current and historical process data via the web (MS IE) For
WinCC DataMonitor new systems, the information server is recommended
SIMATIC Information Server 2014 SP3 Web-based analysis and historical process data reports (browser dependent)
upd4
SIMATIC Process Historian 2014 SP3 Plant-wide archive for messages and process data
upd4
Industrial Data Bridge1) Configurable connections to databases and IT systems
SIMATIC ProDiag allows selective and fast machine and plant diagnostics for SIMATIC
SIMATIC ProDiag S7-1500 and SIMATIC HMI: 6AV2107-0UB00-0BB0

1)
Unrestricted © Siemens 2019 WinCC RT Prof: as Consumer/Provider as sep. application

Page 4 2/19/2020
WinCC RT Professional V16
Engineering Options

Engineering Options Description


Transparency of energy consumption
SIMATIC EnergySuite • SIMATIC Energy Suite Engineering 6AV2108-0AA06-0AA5
(incl. 10 Energy Objects) • SIMATIC Energy Suite S7-1500, 5-100 Energy Objects
SIMATIC Visualization Architect (SiVArc) enables simple, fast, and flexible automated creation of HMI
contents based on the
SIMATIC Visualization Architect STEP 7 user program. 6AV2107-0PX06-0AA5

TIA Portal Multiuser Engineering allows several users to work on the same project simultaneously.

MultiUser 6ES7823-1AA06-0YA5

The TIA Portal Teamcenter Gateway permits storage and management of TIA Portal projects and global
libraries in Teamcenter.
TIA Portal Teamcenter Gateway 6ES7823-1EA06-0YA5

The TIA Portal Cloud Connector enables access to local PC interfaces and connected SIMATIC hardware in
the TIA Portal Engineering even though the engineering itself takes place via remote desktop in a private
TIA Portal Cloud Connector cloud. 6ES7823-1CA00-0YA0

The SIMATIC ODK 1500S allows the development of function libraries with the high-level languages C/C++
SIMATIC ODK 1500S for ODK-capable SIMATIC S7-1500 PLCs. 6AV2108-0AA06-0AA5

The SIMATIC Target 1500S TM for Simulink® is an add-on for Simulink from MathWorks. It allows the
SIMATIC Target 1500S TM for integration of Simulink models directly into the program cycle of an ODK-capable S7-1500 PLC.
6AV2107-0PX06-0AA5
Simulink®

1)
Unrestricted © Siemens 2019 WinCC RT Prof: as Consumer/Provider as sep. application

Page 5 2/19/2020
SIMATIC WinCC Professional
WinCC Premium Add-ons for Process Management

Efficient data management Data consistency over the entire production process

PM-CONTROL Flexible parameter managemnt and job control


PM-QUALITY Batch-based archiving and reporting

Diagnostic management Higher availability of machines and production plants

PM-MAINT Intelligent maintenance management system


PM-ANALYZE Efficient identification of weak points in the process + reporting

Open-mindedness Consolidation of automation and IT world

PM-OPEN-EXPORT Automatic export of process data


PM-OPEN-IMPORT Automatic import of messages and archive values
PM-LOGON Automatic registration, e.g.: via RFID

siemens.com/process-management
\\ww004.siemens.net\bu01$\NbgM\PROJ\PROMOTOREN_VM\VM_WARE_WORLD_WITHOUT_UCL\Inst_SW\2019_01_Install_PM_AddOn
Unrestricted © Siemens 2019
Page 6 2/19/2020
Analysis + Reporting with PM-ANALYZE

Archiving, Display and analysis of alarms • Database and archiving


from several different systems in
• Manual input values
chronological order
• Reporting with Microsoft Excel
• Automatic report generation
• SIMATIC WinCCV7
• Add-in for Microsoft Excel 2007, 2010, 2013, 2016
• PCS7
• Access to all process value and summarization
• WinCC Comfort / RT Professional
archives
• WinCC Advanced
• Access to calculated values and key figures
• WinCC flexible
• Access to messages and operating actions
• Event log of the operating system

Unrestricted © Siemens 2019


Page 7 2/19/2020
WinCC RT Professional V16
Explanation of symbols

WinCC Single-User System S7 System Components

WinCC Server

External Database
WinCC Standard Client e.g.: SQL, Oracle, Access
Ext

3 …
Software to be installed on the
PC without WinCC 1 2
computer

Unrestricted © Siemens 2019


Page 8 2/19/2020
WinCC RT Professional V16
System requirements for supported Operating Systems

• Windows 10 64bit Pro Operating Systems


• Version 1809 (OS Build 17763)
• Version 1903 (OS Build 18362)

• Windows 10 64bit Enterprise


• Version 1809 (OS Build 17763)
• Version 1903

• Windows 10 64bit IoT Enterprise LTSB


• 2015 LTSP (OS Build 10240) (Test for IPC)
• 2016 LTSP (OS Build 14393) (Test for IPC)
• 2019 LTSP (OS Build 17763) (Test for IPC)

• Windows Server 2012 R2 64bit StdE


• Windows Server 2016 64Bit Standard
• Windows Server 2019 64Bit Standard

Office
• Excel 2016
• Build 16.0.6769 (32 or 64 Bit)
• Access to Online Office 365
1) The Windows operating system is only released together with a SIMATIC IPC.

Unrestricted © Siemens 2019


Page 9 2/19/2020
WinCC RT Professional V16
Browser

Microsoft Browser:
• Google Chrome*
• Microsoft Edge
• Mozilla Firefox, Mozilla Firefox ESR

Android Browser:
• Google Chrome*
• Firefox
• Edge

iOS & Mac Browser:


• Safari*
• Google Chrome
• Firefox
• Edge
* Browser with the main focus for this operating system

Unrestricted © Siemens 2019


Page 10 2/19/2020
WinCC RT Professional V16
Supported virtualization software

WinCC Engineering and Runtime

• WinCC Professional V16 & WinCC Runtime Professional V16 are released
for the following virtualization platforms

Runtime Advanced/
Virtualization platforms Engineering
Professional
VMware vSphere Hypervisor (ESXi) ab, 6.5 or higher ✓ ✓
VMware Workstation 12.5.5 / 15.0.2 ✓ 
VMware Player 12.5.5/ 15.0.2 ✓ 
Microsoft Windows Hyper-V Server 2016 or 2019 ✓ ✓

All of the released operating systems can be used as host operating systems
in a virtualization platform.

Unrestricted © Siemens 2019


Page 11 2/19/2020
WinCC RT Professional V16
Compatibility and general information (continued)

Side-by-side installation with all SIMATIC products


Parallel installation von WinCC Runtime Professional V16 and other SIMATIC HMI Products
The parallel installation of WinCC V16 with versions of WinCC flexible before WinCC flexible 2008 SP5 is not permitted.

The parallel installation of WinCC V16 with WinCC V7 is not permitted for:
• WinCC V16 Professional
• WinCC V16 Runtime Professional

Parallel Use
If the software or license key after the installation is named with the affix “Combo”, the use of the following products/versions is permitted:
• With license "STEP 7 Professional Combo": older versions of STEP 7 (STEP 7 Professional 2006 – STEP 7 Professional V16)
• With license "WinCC V16 Comfort Combo": WinCC flexible 2008 Standard
• With license "WinCC V16 Advanced Combo": WinCC flexible 2008 Advanced

Unrestricted © Siemens 2019


Page 12 2/19/2020
WinCC RT Professional V16
Compatibility and general information (continued)

Remote-Software → Link
The following options are available for remote access to WinCC stations:
• NC (Real VNC) Enterprise Edition V5.0.1.
• RDP (Remote Desktop Protocol)

The RealVNC software must be used for remote access to the other computers of a distributed WinCC
system (e.g. WinCC Server).
The Remote Desktop Protocol (RDP) may only be used for remote maintenance of WinCC clients.
Furthermore, no server services (e.g. WebNavigator server, DataMonitor server, OPC server) may be
active on these computers. The reason for this is the handling of the remote desktop sessions by the
Microsoft operating system.

WinCC running in service mode


The service mode allows you to run WinCC Runtime Professional as a service.
WinCC Runtime Professional can also be active as a service if no interactive user is logged on to the computer.

Unrestricted © Siemens 2019


Seite 13 2/19/2020
WinCC RT Professional V16
Compatibility and general information (continued)

Remote Software: Using RealVNC→ Link


The following scenarios were tested:

• WinCC as a single-user system


• WinCC as a distributed system
• WinCC in redundant operation
• WinCC/WebUX Server

You can also use communication via OPC in the released scenarios.
Start Remote Desktop
Access to WinCC systems with a Remote Desktop Client is only possible via a console session.
Access via the Remote Desktop Protocol may only take place via console transfer with the same user or
initial logon.

Unrestricted © Siemens 2019


Seite 14 2/19/2020
SIMATIC WinCC RT Professional
Upgrade for Power Tags at WinCC in TIA Portal (to V16)

… WinCC RT Professional V11… –> V16 RT SUS (V16)

WinCC RT Professional RT Client 6AV2107-0DB00-0AL0

6AV2105-3BB06-0AE0
WinCC RT Professional 128

6AV2105-3DD06-0AE0
WinCC RT Professional 512

6AV2105-3FF06-0AE0
WinCC RT Professional 2k
6AV2105-0XA00-0AL0
6AV2105-3HH06-0AE0
WinCC RT Professional 4k

6AV2105-3KK06-0AE0
WinCC RT Professional 8k

6AV2105-3MM06-0AE0
WinCC RT Professional 64k-250k

The information in SIOS is available: https://support.industry.siemens.com/cs/ww/en/view/109751896

Unrestricted © Siemens 2019


Page 15 2/19/2020
SIMATIC WinCC Professional
Powertags

Server
The number of WinCC Runtime Professional PowerTags for the server is
selectable.
Power Packs extend the number of available tags.
The total price remains constant.

Client
The Client is being deployed for
• WinCC RT Professional Client
Or
128 512 2k 4k 8k 64k 100k 150k 256k
• WinCC RT Professional 128

Unrestricted © Siemens 2019


Page 16 2/19/2020
SIMATIC WinCC Professional Engineering
Upgrade WinCC in TIA Portal (V13.SPx to V16)

WinCC Prof. WinCC


V11 - V16 Prof. V16

Online Software
… WinCC Professional V11 to V16 SUS
Delivery
• WinCC Professional V16 512 6AV2103-3DA06-0AE5 6AV2103-3DA06-0AK5
• WinCC Professional V16 4096 6AV2103-3HA06-0AE5 6AV2103-3HA06-0AK5
• WinCC Professional V16 max. 6AV2103-3XA06-0AE5 6AV2103-3XA06-0AK5
6AV21030DA000AY0
• WinCC Prof.V16 512 Powertags SUS DL
• WinCC Prof.V16 4096 Powertags SUS DL 6AV21030HA000AY0
• WinCC Prof.V16 max. Powertags SUS DL 6AV21030XA000AY0

Unrestricted © Siemens 2019


Page 17 2/19/2020
SIMATIC WinCC Professional
Migration from WinCC V7 RC/RT
WinCC V7.2 WinCC Professional. V13 SP1

WinCC V7.3 WinCC Professional V14

WinCC V7.4 WinCC Professional V14 SP1

WinCC V7.4 SP1 WinCC RT Professional V15.1

WinCC V7.5 WinCC RT Professional V16


WinCC RC/RT V7.0…V7.5 → WinCC V16 OSD
V7 RT Client → WinCC RT Professional Client 6AV2107-4DB06-0AE0 6AV2107-4DB06-0AK0
V7 RC/RT 128 → RT Prof. 128 6AV2105-4BB06-0AE0 6AV2105-4BB06-0AK0
V7 RC/RT 512 → RT Prof. 512 6AV2105-4DD06-0AE0 6AV2105-4DD06-0AK0
V7 RC/RT 2k → RT Prof. 2k 6AV2105-4FF06-0AE0 6AV2105-4FF06-0AK0
V7 RC/RT 8k → RT Prof. 8k 6AV2105-4KK06-0AE0 6AV2105-4KK06-0AK0
V7 RC/RT 64k → RT Prof. >= 64k 6AV2105-4MM06-0AE0 6AV2105-4MM06-0AK0

When upgrading from V7 RC/RT, ONLY the RT Professional license will be delivered with immediate effect. The
WinCC Professional Engineering software must be ordered separately if required.

Unrestricted © Siemens 2019


Page 18 2/19/2020
Engineering: WinCC RT Professional V16
The following security programs were tested:

• Trend Micro "Office Scan" 12.0


• Symantec Endpoint Protection V14.0
• McAfee Endpoint Security (ENS) 10.5
• Kaspersky Endpoint Security 11.1
• Windows Defender (version contained in the operating system)
• Qihoo 360 "Safe Guard 11.5" + "Virus Scanner"

Unrestricted © Siemens 2019


Page 19 2/19/2020
WinCC RT Professional V16
Licenses

Runtime
• WinCC differentiates between RT licenses (Runtime) and ES licenses (Configuration) as well as the number of tags.
• RT licenses permit the operation of WinCC in runtime for an unlimited period of time.
With this license you can use up to 262 144 external tags and up to 500 archive tags (WinCC Logging) in Runtime.
Engineering is not possible.
• New :... the license for sporadic use:50h of actual use – where the usage can be interrupted as often as required
Activation 50 h

Valid License Key Expired License Key

Engineering
A license key is required for:
• WinCC Engineering System, e.g. WinCC Professional
• Options for WinCC Engineering System

Web options
• The license type of the web options (WEBNAVIGATOR, DATAMONITOR and WebUX ) becomes consistently countable.

Unrestricted © Siemens 2019


Page 20 2/19/2020
SIMATIC WinCC Professional V16
Order data Logging

… Runtime Professional V16 Logging*) Online Software Delivery


• 1500 Logging Tags 6AV2107-0GB00-0BB0 6AV2107-0GB00-0BH0
• 5000 Logging Tags 6AV2107-0GD00-0BB0 6AV2107-0GD00-0BH0

• 1500 -> 5000 Logging Tag Not applicable due to conversion to additive licenses!

• WinCC Professional contains 500 Archive Tags in the base system


• WinCC Logging Tags are expandable by:1500 and 5000. +5000 Archive Tags
+1500 Archive Tags
• Archive licenses can be combined/ pooled (countable licenses). 500 Archive Tags 7000
2000

• WinCC Professional supports up to 80k Archive Tags

*) Number of tags are additive, i.e. total archive tags = sum of individual licenses

Unrestricted © Siemens 2019


Page 21 2/19/2020
WinCC RT Professional V16 basic station
Article numbers

SIMATIC WinCC Professional xx PowerTags V16 Engineering


Order number EU Order number ASIA
Description
DVD Online Software Download DVD

512 PowerTags 6AV2103-0DA06-0AA5 6AV2103-0DA06-0AH5 -


4096 PowerTags 6AV2103-0HA06-0AA5 6AV2103-0HA06-0AH5 -
Max PowerTags 6AV2103-0XA06-0AA5 6AV2103-0XA06-0AH5 -
NEW: SIMATIC 50h Engineering
with STEP 7 Professional V14 SP1 Combo, SIMATIC 50h Engineering with
6ES7823-1GE06-0YA5 -
STEP 7 Professional Combo, WinCC Professional (incl. WinCC flexible 2008)
and STEP 7 Safety Advanced (incl. Distributed Safety)

SIMATIC WinCC Runtime Professional … PowerTags V16 Basis Package (RT incl. 500 Archive Variables)
(RT incl. 500 Archive Variables and one WebUX Monitor Client)
128 PowerTags 6AV2105-0BA06-0AA0 6AV2105-0BA06-0AH0 6AV2105-0BA16-0AA0
512 PowerTags 6AV2105-0DA06-0AA0 6AV2105-0DA06-0AH0 6AV2105-0DA16-0AA0
2048 PowerTags 6AV2105-0FA06-0AA0 6AV2105-0FA06-0AH0 6AV2105-0FA16-0AA0
4096 PowerTags 6AV2105-0HA06-0AA0 6AV2105-0HA06-0AH0 6AV2105-0HA16-0AA0
8192 PowerTags 6AV2105-0KA06-0AA0 6AV2105-0KA06-0AH0 6AV2105-0KA16-0AA0
65536 PowerTags AV2105-0MA06-0AA0 6AV2105-0MA06-0AH0 6AV2105-0MA16-0AA0
102400 PowerTags 6AV2105-0PA06-0AA0 6AV2105-0PA06-0AH0 6AV2105-0PA16-0AA0
153600 PowerTags 6AV2105-0RA06-0AA0 6AV2105-0RA06-0AH0 6AV2105-0RA16-0AA0
262144 PowerTags 6AV2105-0TA06-0AA0 6AV2105-0TA06-0AH0 6AV2105-0TA16-0AA0
WinCC Client for RT Prof V15 6AV2107-0DB06-0AA0 6AV2107-0DB06-0AH0 6AV2107-0DB16-0AA0
Please note the price advantage for Online Software Delivery!
Unrestricted © Siemens 2019 Note: WinCC Professional V16 can also be configured with a WinCC Unified Engineering (max license).
Page 22 2/19/2020
SIMATIC WinCC Professional
Order Data Engineering / Trial

Link to compatibility list: Compatibility List

… Trial Software Online Software Delivery


• Engineering Trial Software V16
WinCC Basic / Comfort / Advanced 6AV2102-0AA06-0AA7

• SIMATIC WinCC Professional V16,


6AV2103-0AA06-0AA7 Download in Customer Support Portal
• Trial License

Unrestricted © Siemens 2019


Page 23 2/19/2020
Integrated licensing concept
NEW as of WinCC V7.4 / RT Professional V14

Web solutions with WebNavigator and WebUX Scalable web access


In the future, these SCADA options will have Switching between two license models:
standardized MLFBs as of V7.4 or V14 and
therefore there will no longer be any in-house • Separate or combined Web-licenses
MLFBs for WinCC RT Professional V15 WebUX Monitor Client (read only)
WebUX Operate Client (read-write)
Separate Web Combined Web Web Navigator Client (read-write)
licenses licenses
WebNavigator Web Licenses are additive:
all WebClients = sum of the individual licenses (countable)
WebUX WebUX • (1, 3, 10, 30, 100 clients)
WebNavigator
Operate Operate • Reserving licenses for users
Monitor Monitor • No update costs, because version-independent
licenses (existing licenses remain valid after upgrade)
IIS on Windows 10 supports a maximum of ten connections or instances. WebUX
requires more than one connection for a client. Therefore, a maximum of three WebUX
clients can connect to the WebUX server.If the limit is exceeded, you can no longer 1x WinCC WebUX Monitor Client FREE!
operate the instances already connected

Unrestricted © Siemens 2019


Page 24 2/19/2020
Integrated licenses
NEW as of WinCC V7.4 SP1 / WinCC RT Professional V14

WinCC WebNavigator (countable)


Order number: Order number Order number:
Description DVD Online Software Download DVD
EU EU ASIA
WinCC WebNavigator - 1 Client 6AV6362-1AB00-0BB0 6AV6362-1AB00-0AH0 6AV6362-1AB00-0BB0
WinCC WebNavigator - 3 Clients 6AV6362-1AD00-0BB0 6AV6362-1AD00-0AH0 6AV6362-1AD00-0BB0
WinCC WebNavigator - 10 Clients 6AV6362-1AF00-0BB0 6AV6362-1AF00-0AH0 6AV6362-1AF00-0BB0
WinCC WebNavigator - 30 Clients 6AV6362-1AJ00-0BB0 6AV6362-1AJ00-0AH0 6AV6362-1AJ00-0BB0
WinCC WebNavigator - 100 Clients 6AV6362-1AM00-0BB0 6AV6362-1AM00-0AH0 6AV6362-1AM00-0BB0
WinCC WebNavigator Diagnostic Client 6AV6362-1BA00-0BB0 6AV6362-1BA00-0AH0 6AV6362-1BA00-0BB0

WinCC DataMonitor (countable)


Order number: Order number : Order number:
Description DVD Online Software Download DVD
EU EU ASIA

WinCC DataMonitor - 1 Client 6AV6362-3AB00-0BB0 6AV6362-3AB00-0AH0 6AV6362-3AB00-0BB0

WinCC DataMonitor - 3 Clients 6AV6362-3AD00-0BB0 6AV6362-3AD00-0AH0 6AV6362-3AD00-0BB0

WinCC DataMonitor - 10 Clients 6AV6362-3AF00-0BB0 6AV6362-3AF00-0AH0 6AV6362-3AF00-0BB0

WinCC DataMonitor - 30 Clients 6AV6362-3AJ00-0BB0 6AV6362-3AJ00-0AH0 6AV6362-3AJ00-0BB0

Unrestricted © Siemens 2019


Page 25 2/19/2020
Integrated licenses
NEW from WinCC V7.4 / WinCC RT Professional V14

WinCC WebUX (Monitor countable)


Order number: Order number Order number:
Description DVD Online Software Download DVD
EU EU ASIA
WinCC WebUX Monitor 1 Client 6AV6362-2AB00-0BB0 6AV6362-2AB00-0AH0 6AV6362-2AB00-0BB0

WinCC WebUX Monitor 3 Clients 6AV6362-2AD00-0BB0 6AV6362-2AD00-0AH0 6AV6362-2AD00-0BB0

WinCC WebUX Monitor 10 Clients 6AV6362-2AF00-0BB0 6AV6362-2AF00-0AH0 6AV6362-2AF00-0BB0

WinCC WebUX Monitor 30 Clients 6AV6362-2AJ00-0BB0 6AV6362-2AJ00-0AH0 6AV6362-2AJ00-0BB0

WinCC WebUX Monitor 100 Clients 6AV6362-2AM00-0BB0 6AV6362-2AM00-0AH0 6AV6362-2AM00-0BB0

WinCC WebUX (Operate countable)


Order number: Order number Order number:
Description DVD Online Software Download DVD
EU EU ASIA
WinCC WebUX Operate 1 Client 6AV6362-2BB00-0BB0 6AV6362-2BB00-0AH0 6AV6362-2BB00-0BB0

WinCC WebUX Operate 3 Clients 6AV6362-2BD00-0BB0 6AV6362-2BD00-0AH0 6AV6362-2BD00-0BB0

WinCC WebUX Operate 10 Clients 6AV6362-2BF00-0BB0 6AV6362-2BF00-0AH0 6AV6362-2BF00-0BB0

WinCC WebUX Operate 30 Clients 6AV6362-2BJ00-0BB0 6AV6362-2BJ00-0AH0 6AV6362-2BJ00-0BB0

WinCC WebUX Operate 100 Clients 6AV6362-2BM00-0BB0 6AV6362-2BM00-0AH0 6AV6362-2BM00-0BB0

Unrestricted © Siemens 2019


Page 26 2/19/2020
WinCC RT Professional V16 ?
In which case WinCC RT Advanced / WinCC V7 ?

WinCC RT Advanced WinCC V7

• Single user system with max 16 384 PowerTags • 18 servers


• No clients • 64 clients or
• Support of bit messages and analog messages as • 50 multi-clients
well as the event-controlled alarm procedure • 150 web clients
Alarm-S / D for SIMATIC S7
• 2 Server (redundant)
• Recipes:
• Possibility to connect to SAP Hana/SAP R3 via
Creation of data sets for machine data or
PM Add ons
production data
• KPI evaluation (see V7 Performance Monitor)
• WinCC Logging
For archiving variables and messages • Connection of telecontrol stations (WinCC V7
TeleControl )
• Generierung from Tags, Messages, pictures,
Trend with VBA

Unrestricted © Siemens 2019
Page 27 2/19/2020
WinCC RT Professional V16
In which case WinCC RT Professional V16?

Project TIA Portal for SPS / SCADA System Architecture

• Perfect integration into the TIA Portal => customer good SCADA solution for small to medium solutions
has been using and is familiar with the TIA Portal
for a long time 1 server (optional redundant) maximum 32 clients
• WinCC integrated
• System diagnosis, time stamping at source
• Process diagnosis
• SIMATIC Energy Suite
• Generierung from pictures with SiVArc
• Intelligentes Lastmanagement

Unrestricted © Siemens 2019


Seite 28 2/19/2020
WinCC RT Professional V16
Communication with the process

WinCC RT Prof Ethernet Card of the PC:


• SOFTNET-IE S7
max. 64 connections (6GK1704-1CW16-0AA0)
PROFIBUS Network Ethernet Network • SOFTNET-IE S7 Extended
max. 128 connections (6GK1704-1BW16-0AA0)
With CP
• CP 1623 PCIe: (6GK1162-3AA00 )

CP 5621 PCIe Softnet Module Ethernet Card of the PC


• Protocols 1200/1500, S7 TCP/IP, Ind. Eth
• S7 MPI/PROFIBUS protocols included in WinCCCP 5613 A2 PCI • Licenses for
Hardnet Module • SOFTNET-IE S7 Lean max. 8 connections (included in the WinCC
package)
• S7 MPI/PROFIBUS protocols • With > 8 connections => license required for Softnet-IE S7
• A license is required
CP 1623 PCIe Hardnet Assembly (license for Hardnet-IE S7 (S7 1613) required)
• It is recommended that you use separate network cards for reducing the load on the PC-
WinCC RT Professional V16 supports max 128 S7 connections CPU
of which: • max. 128 x S7-1500/1200 Connections Example:
• max. 64 x S7-1500/1200 Connections - LAN Card 1: 64 x 1200/1500
-max. 128 x S7-1200 / S7-1500 Connections • max. 64 x S7-300/400 Connections + LAN Card 2: 64 x 300/400
-max. 64 x S7-300/400 Connections

Unrestricted © Siemens 2019


Page 29 2/19/2020
Single-user system
Operator control and monitoring with a single PC

1 Basis Paket =
Single-user system SIMATIC WinCC Runtime
Engineering Station+ Professional PowerTags V16
WinCC RT Prof
WinCC RT Prof n
e. g.:
1 • 512 PowerTags
2 • 2048 PowerTags
• 4096 PowerTags
• 8192 PowerTags
• 65 536 PowerTags
• 102 400 PowerTags
• 153 600 PowerTags
• 262 144 PowerTags
SIMATIC Net V16

Additional information 2 SIMATIC WinCC Engineering


• Quantity Structure: System Base Package V16
• Process tags: up to 262 144 (depending on license selected) • 512 PowerTags
• Archive tags: max. 80 000 (depending on WinCC Logging option) • 4096 PowerTags
• Max. PowerTags
(Note: WinCC Pro 500 archive tags are included in the basic version.)

Unrestricted © Siemens 2019


Page 30 2/19/2020
Redundant single-user systems - 2 operator control and
monitoring stations with a high degree of availability

1 Base Package
Engineering 2
Station WinCC RT Prof n
SIMATIC Net V16

3 1 1 2 WinCC Redundancy
Redundant WinCC
Single-user systems MLFB: 6AV2107-0FB00-0BB0

3 WinCC Engineering
• 512 PowerTags
• 4096 PowerTags
• max PowerTags

Additional information
• The two stations run in parallel (both are connected to the process). In the event of a fault
• in one of the two WinCC stations, the other takes over the archiving of messages,
and the process/user data (recipe). Automatic synchronization of all archives
• after restoration of the normal operating state.

Unrestricted © Siemens 2019


Page 31 2/19/2020
Redundant Single-User Systems
Engineering station

1 Base Package
Engineering 2
Station WinCC RT Prof n
SIMATIC Net V16

3 2 WinCC Redundancy
1 1 Redundant WinCC
single-user systems MLFB: 6AV2107-0FB00-0BB0

3 WinCC Engineering
• 512 PowerTags
• 4096 PowerTags
• max PowerTags

IMPORTANT
Changes can be made in the two WinCC servers via the engineering station.
The requirement for this is that the engineering station must be configured, for example, with:
• WinCC Prof V16 or
• WinCC Prof V16 + STEP 7 Basic V16 (S7-1200) or STEP 7 Prof V16 (S7-1500)

Unrestricted © Siemens 2019


Page 32 2/19/2020
WinCC Recipes
Recipe management

WinCC Clients 1 Base Package


WinCC 2 WinCC 2 WinCC 2 WinCC RT Prof
… SIMATIC Net V16
2 WinCC Client
MLFB: 6AV2107-0DB06-0AA0
1 3 RT Pro Server
3 WinCC Server
4
MLFB: 6AV2107-0EB00-0BB0

4 WinCC Recipes
MLFB: 6AV2107-0JB00-0BH0

With WinCC Recipes, the user can manage his archives in tabular form,
E. g.: Recipe management – managing the batch parameters, ...
The recipe license is located on the server.

Unrestricted © Siemens 2019


Page 33 2/19/2020
WinCC Logging
Archive tags

WinCC Clients 1 Base Package


WinCC 2 WinCC 2 WinCC 2 WinCC RT Prof
… SIMATIC Net V16
2 WinCC Client
MLFB: 6AV2107-0DB06-0AA0
1 3 RT Pro Server
3 WinCC Server
4 MLFB: 6AV2107-0EB00-0BB0

4 WinCC Logging
e. g.: 1500 archive tags
MLFB: 6AV2107-0GB00-0BB0
The number of the archive tags can be increased with WinCC Logging. e. g.: 5000 archive tags
(countable licenses) MLFB: 6AV2107-0GD00-0BB0
• The license for 500 archive tags is included in the basic package.
• The logging license is located on the server.
• With a license for 1500 archive tags and the basic license for 500 archive tags, you then have
2000 archive tags at your disposal

Unrestricted © Siemens 2019


Page 34 2/19/2020
Multi-user systems – central server with operating and
monitoring stations: Only standard client

WinCC Clients 1 Base Package

WinCC RT Prof n
2 WinCC 2 WinCC 2 WinCC
SIMATIC Net V16
… 2 WinCC Client
MLFB: 6AV2107-0DB06-0AA0
1 – 32 WinCC Clients
1 3
WinCC RT Prof Server 3 WinCC Server
MLFB: 6AV2107-0EB00-0BB0

Please note

A standard client does not have a WinCC project. It is connected to a specific server
from which it receives data and views.

Unrestricted © Siemens 2019


Page 35 2/19/2020
Multi-user systems with standard clients – Engineering
Scenario 1 – Development on the server

Case 1: The engineering license is located on the server. Changes


to the project are made directly on the server. 1 Base Package
WinCC RT Prof n
2 WinCC 2 WinCC 2 WinCC SIMATIC Net V16
Standard
Clients … 2 WinCC Client
MLFB: 6AV2107-0DB06-0AA0
1 – 32 WinCC Clients
1 3
WinCC RT Prof Server + 3 WinCC Server
4 Engineering
MLFB: 6AV2107-0EB00-0BB0

4 WinCC Engineering
• 512 PowerTags
• 4096 PowerTags
• max PowerTags
To be observed – Differences compared to the preceding scenario:
An engineering license is also required on the server.
TIA is possible (i.e. STEP 7 can be installed on the server.)

In the event of changes, it may be necessary to shut down the server.

Unrestricted © Siemens 2019


Page 36 2/19/2020
Multi-user systems with standard clients – Engineering
Scenario 2 – Engineering station

Case 2: Changes are made on an in-house engineering station 1 Base Package


(e.g.: work station of a system integrator who is not constantly connected)
4 WinCC RT Prof n
2 WinCC 2 WinCC 2 WinCC Engineering SIMATIC Net V16
Standard
Station
Clients … 2 WinCC Client
MLFB: 6AV2107-0DB06-0AA0
1 – 32 WinCC Clients
1 3
WinCC RT Prof 3 WinCC Server
Server
MLFB: 6AV2107-0EB00-0BB0

4 WinCC Engineering
• 512 PowerTags
• 4096 PowerTags
• max PowerTags
IMPORTANT

Changes can be made on the WinCC server via the engineering station.
The requirement for this is that the engineering station must be configured.

Unrestricted © Siemens 2019


Page 37 2/19/2020
Multi-user systems with standard clients – Engineering
Scenario 3 – Engineering station on a client

Case 3: Changes are made on an engineering station that is running on a client


1 Base Package
(e.g.: work station of a maintenance employee)
4 Engineering WinCC RT Prof n
2 WinCC 2 WinCC WinCC Station SIMATIC Net V16
Standard 2
Clients … 2 WinCC Client
MLFB: 6AV2107-0DB06-0AA0
1 – 32 WinCC Clients
1 3
WinCC RT Prof 3 WinCC Server
Server
MLFB: 6AV2107-0EB00-0BB0

4 WinCC Engineering
WinCC Prof (512 / 4096 / max )

IMPORTANT

Changes can be made on the WinCC server via the engineering station.
The requirement for this is that the engineering station must be configured.

Unrestricted © Siemens 2019


Page 38 2/19/2020
Analysis + Reporting with PM-ANALYZE
Installation Variants

*Installation on a separate server requires a Microsoft SQL Server 2008, 2014,2016 (32/64).

PM-ANALYZE Client
(With/Without WinCC PM-ANALYZE Server
Client) (Without WinCC)

WinCC Server
PM-AGENT

WinCC Comfort Panels


OPC UA

Distributed System

Unrestricted © Siemens 2019


Page 39 2/19/2020
SIMATIC Information Server –
Reporting System in the web

PC with reporting with dashboards on 1 Base Package


HTML5-capable browser or via Office (Microsoft Excel, Word, PowerPoint) WinCC RT Prof n
SIMATIC Net V16

Internet
2 WinCC IS 2014 SP3 upd4
Base Package
MLFB: 6AV6361-2AA01-4AA0
LAN
The base package contains:
1 • 1 x data source access
WinCC single-user
2 system with (connection with a WinCC database)
IS2014 SP3 upd4 • 3 x client access
(three simultaneous client accesses)

Note:
Information Server 2014 SP3 upd4
is compatible with
Additional Information -WinCC RT Prof V13 SP1 or higher
-WinCC 7.0 SP3 or higher
Standard and user-specific reports (via Report Builder of MS SQL Reporting Services)
-WinCC OA 3.14 or higher
Transparent access to WinCC-Archive in Excel and Word (2007, 2010, 2013 and 2016).
-SIMATIC Process Historian 2014 SP2

Unrestricted © Siemens 2019


Page 40 2/19/2020
SIMATIC Information Server –
Reporting system in the web

WinCC Clients 1 Base Package


WinCC 2 WinCC 2 WinCC 2 WinCC 2 WinCC RT Prof n
SIMATIC Net V16
2 WinCC Client
MLFB: 6AV2107-0DB06-0AA0
1 3 5
1 3
Redundant 3 WinCC Server
6 7
WinCC MLFB: 6AV2107-0EB00-0BB0
Server
4 4 WinCC Redundancy
PH + Information
Server MLFB: 6AV2107-0FB00-0BB0
5 Process Historian 2014 SP3 upd4
MLFB: 6AV6361-1AA01-4AA0
Additional Information 6 WinCC IS 2014SP3 Base Package

PH and Information Server can be installed on the same computer. MLFB: 6AV6361-2AA01-4AA0
If IS is connected to PH, no "IS DataSource Access" license is needed.
7 WinCC IS Client Access (1)
MLFB: 6AV6361-2BD00-0AD0

Unrestricted © Siemens 2019


Page 41 2/19/2020
Single-User Web Server
Remote web client on the Internet/intranet

With Internet Explorer or WinCC ViewerRT 1 – 100 Web Clients 1 Base Package

WinCC RT Prof n
Internet/intranet
SIMATIC Net V16

2
WinCC WebNavigator
LAN
1
RT Prof Web z. B.: for three clients
2 Server Single-User MLFB: 6AV6362-1AD00-0BB0
System

Additional Information
WinCC/WebNavigator allows operator control and monitoring from a remote operator station via a local intranet or the Internet.

In each case, a web license for n clients allows a simultaneous connection with the WinCC web server for these n clients

Unrestricted © Siemens 2019


Page 42 2/19/2020
Single-user web server with HTML5 web clients:
WebUX allows remote web client on the internet/intranet
via tablets/smartphones
1 Base Package
WinCC RT Prof n
Interne/Intranet SIMATIC Net V16
2 WinCC WebUX
Any 3 web HTML5 clients
e.g.: for 3 clients
LAN
1 MLFB: 6AV6362-2BD00-0BB0
Web server single-user system
2

Additional information
In this case, three clients HTML5 can access to the WebUX server without any installation from the client
side.
WebUX is based on a secure connection and needs a certificate.
Note: The security certificate must be renewed after one year.
Because of some limitations in comparison to WebNavigator, please verify that WebUX is suitable for the
required operations.

Unrestricted © Siemens 2019


Page 43 2/19/2020
Remote diagnostics of WinCC systems in connection with
WebNavigator / WebUX - Combined licenses for
WebNavigator / WebUX and Diagnostic Client
Remote diagnostics of WinCC systems 1 Base Package
in connection with WebNavigator
WinCC RT Prof n
4 SIMATIC Net V16
Internet

2 WinCC WebNavigator

Any 3 Web Clients e. g.: for three Clients


1 MLFB: 6AV6362-1AD00-0BB0
Webserver Single-User System
2 3 WinCC WebUX
e. g.: WebUX Operate 3 Clients
MLFB: 6AV6362-2BD00-0BB0

4 WinCC WebDiagnostics Client

Additional Information MLFB: 6AV6362-1BA00-0BB0


The WebNavigator license can allow the access even from WebUX HTML5 clients combined to
WebNavigator desktop clients.
In this case, a WebNavigator license for three clients allows connection from any three
WebNavigator/WebUX clients, depending on the configuration.

As example, a fourth stand-alone client with the Diagnostics License can access to the server anytime!
Unrestricted © Siemens 2019
Page 44 2/19/2020
Web server single-user system – Special case with only one
web connection (WebNavigator Diagnostics)

WebDiagnostics Client 1 Base Package

2 WinCC RT Prof n
Internet SIMATIC Net V16
2 WinCC WebDiagnostics Client

MLFB: 6AV6362-1BA00-0BB0

1
Webserver-
Single-User System

Additional Information
In contrast to the preceding case, the license is installed on a web client.
Thus, no license is necessary on the server(s) for this client.
Several diagnostic clients can be connected to a diagnostics server

Unrestricted © Siemens 2019


Page 45 2/19/2020
Web-Solution 1:
Web Solution based on (RDP-Clients) on Industrial Thin
Client V3
3 1 – 25 Thin Clients (RDP-Clients) 1 Base Package
Internet
WinCC RT Prof n
Web Clients SIMATIC Net V16
2 WinCC WebNavigator
e. g.: for 10 Clients
1 2 MLFB: 6AV6362-1AF00-0BB0
RT Prof Webserver
Single-User System

3 Thin Client V3 /
Thin Client V3 PRO
6AV6646-1BA15-0AA0 SIMATIC ITC1500 V3
6AV6646-1BA15-0NA0 SIMATIC ITC1500 V3
6AV6646-1BA18-0AA0 SIMATIC ITC1900 V3
With the services of the Windows Terminal Server, the functionalities of the WebNavigator can be used for 6AV6646-1BA18-0NA0 SIMATIC ITC1900 V3
thin clients (limited resources and 6AV6646-1BA22-1AA0 SIMATIC ITC2200 V3
operating system not supported by WinCC) Example: SIMATIC Thin Client 6AV6646-1BA22-1NA0 SIMATIC ITC2200 V3
The ITC V3 supports the protocols RDP, VNC and Sm@rtserver

https://support.industry.siemens.com/cs/ww/en/view/109758315

Unrestricted © Siemens 2019


Page 46 2/19/2020
Web Solution 2:
Operator control and monitoring of WinCC systems with
HTML 5 browser (Tablet / PC / WebPanel)
1 Base Package
WinCC RT Prof n
SIMATIC Net V16
Internet 2 WinCC WebUX
e. g.: for 10 Clients
3 any WebUX-Clients
1 2 MLFB: 6AV6362-1AF00-0BB0
RT Prof Webserver
Single-User System

3 WebPanel

Attention:
Standard ThinClient V3 uses a Mozilla Firefox
Additional Information browser that is not optimal for WebUX

WebPanel (Linux based software ) Please order the new WebPanel based on Thin
Integrated current Chromium Browser v66 (perfect for WebUX) Client V3 with the new Google Chrome
browser
The IWP software supports different hardware architect (Basic Panels / ITC /IPC

Unrestricted © Siemens 2019


Page 47 2/19/2020
Virtualization for WinCC clients and/or server

Example: Virtual WinCC clients on Hypervisor


1 Base Package
2 Thin clients via remote access to the WinCC RT Prof n
2 WinCC clients of the host computer SIMATIC Net V16
2
2 WinCC Client
MLFB: 6AV2107-0DB06-0AA0
1 3 RT Prof Server
3 WinCC Server
MLFB: 6AV2107-0EB00-0BB0

WinCC clients run with the Hypervisor system.


WinCC servers can also be operated using the Hypervisor system.
The maximum number of clients that the virtualization server can host depends on the physical resources
of the host computer
• RAM, SSD
• CPU, Number of Core

Unrestricted © Siemens 2019


Page 48 2/19/2020
Functional differences between
WinCC RT Professional V16 and WinCC 7.5 SP1

Functions WinCC RT Professional V16 WinCC V7.5 SP1

ES: 512, 4k, max. RC: 128, 512, 2k, 8k, 64k, 100K, 150K, 256k
PowerTags
RT: 128, 512, 2k, 4k, 8k, 64k, 100K, 150K, 265k RT: 128, 512, 2k, 8k, 64k, 100K, 150K, 265k

Screens / screen objects No limit / no limit No limit / no limit

Alarms 150,000 150,000

256 alarm classes, 32 types in groups, 256 alarm classes


17 alarm priorities 17 alarm priorities (0 to 16)
18 servers / 64 clients
Server/client 1 server / 32 clients
50 multi-clients

Logging *) Archive tags add. 1,500, 5,000 Archive tags add. 1,500, 5,000, 10k, 30k, 80k
500/ 512 archive tags incl.
max. 80,000 (server) max. 80,000 (server)
Recipes: 500 / Recipes: No limit /
Recipes **)
Elements per recipe: 10 000 Elements per recipe: 100,000
WebNavigator
1, 3, 10, 30, 100 clients 1, 3, 10, 30, 100 clients ( in WinCC V7.3 max.150 clients)
WebUX
PLC Connections Up to 128 connections, 128 x S7-1500/ 32 x S7-1200 / 64 x S7-300/400
*) V7.x: Archive tags -max. 128 x S7-1200 / S7-1500 Connections
**) V7.x: UserArchives -max. 64 x S7-300 / 400 Connections

Unrestricted © Siemens 2019


Page 49 2/19/2020
Functional differences between
WinCC RT Professional V16 and WinCC 7.5 SP1

Communication WinCC Professional V16 WinCC V7.5 SP1

MPI/PROFIBUS Yes Yes

OPC UA OPC UA Server : DA, HA, A&C (Alarm & Condition) UA Server: DA, HA, A&C (Alarm & Condition)

OPC UA Client: DA UA Client: DA, A&C

SIMOTION OPC UA Yes

SINUMERIK NO Add-on

Allen Bradley Ethernet/IP Ethernet/IP

Modicon Modbus (TCP) Modbus (TCP)

Mitsubishi MC TCP/IP i-QR PLCs

IEC Client NO IEC 61850 (Add-on)

DNP3 NO Option Telecontrol

MQTT NO WinCC Cloud Connect

Unrestricted © Siemens 2019


Page 50 2/19/2020
SIMATIC WinCC Professional
Hardware and software from a single source - Order
Packages
Package Runtime Licenses Available SIMATIC IPC
WinCC RT Professional Client 6AV2117-2DB06-0AA0

WinCC RT Professional 128 PT 6AV2115-2BA06-0AA0


All SIMATIC IPC
WinCC RT Professional 512 PT 6AV2115-2DA06-0AA0

WinCC RT Professional 2048 PT 6AV2115-2FA06-0AA0


Box, Panel, Rack PCs

WinCC RT Professional 4096 PT 6AV2115-2HA06-0AA0

WinCC RT Professional 8192 PT 6AV2115-2KA06-0AA0


IPC227D and IPC277D
WinCC RT Professional 65536 PT 6AV2115-2MA06-0AA0

Up to 30% price advantage Available packages for SIMATIC IPC


(vs. regular WinCC list price) SIOS - IPC Packages

Only if ordered simultaneously with the SIMATIC IPC.


Please always observe the operating system requirements of the WinCC system.

Unrestricted © Siemens 2019


Page 51 2/19/2020
Promoter selection help –
Software packages for SIMATIC IPCs Additional information

WinCC WinCC RT WinCC RT


WinCC V7.x
flexible RT Advanced Professional

2x7D/E
client client

4x7D

6x7 / 8x7 C/E

647 / 847 C/D

547E/G

347E

Unrestricted © Siemens 2019


Page 52 2/19/2020
Promoter selection help –
Software packages for SIMATIC IPCs Additional information

WinCC WinCC RT WinCC RT


WinCC V7.x
flexible RT Advanced Professional

2x7E

377E
client client

ITP1000

647 / 847C/D/E

127E
? (Worked, but not system tested)

Unrestricted © Siemens 2019


Page 53 2/19/2020
Subject to changes and errors. The information given in this document only contains general descriptions and/or
performance features which may not always specifically reflect those described, or which may undergo modification in the
course of further development of the
products. The requested performance features are binding only when they are expressly
agreed upon in the concluded contract.

All product designations, product names, etc. may contain trademarks or other rights of Siemens AG, its affiliated
companies or third parties.
Their unauthorized use may infringe the rights of the respective owner.

Unrestricted © Siemens 2019


Page 54 2/19/2020

You might also like