6AV21070DB020AH0
6AV21070DB020AH0
6AV21070DB020AH0
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
■ Overview ■ Design
PC-based operator control and monitoring system for visual- SIMATIC WinCC Runtime Professional is available as a software
ization and operator control of processes, production flows, package with 128, 512, 2 048, 4 096, 8 192, 65 536 PowerTags.
machines and plants in all sectors – from the simple single-user
station through to distributed multi-user systems and cross- PowerTags are data points that are connected to controllers or
location solutions with web clients. other data sources via a WinCC Runtime Professional channel.
Up to 32 alarms can be obtained from one data point. Moreover,
SIMATIC WinCC Runtime Professional is the information hub for internal tags without coupling are available for additional system
corporation-wide vertical integration. SIMATIC WinCC Runtime performance.
Professional is configured with the SIMATIC WinCC Professional
configuration software. WinCC Runtime Professional also contains 500 archive tags.
Additional archive licenses can be obtained for greater quantity
structures.
■ Benefits
Licenses for a multi-user configuration
• Functions for all visualization tasks:
- Operator functions The system software with the required number of PowerTags and
- Graphics and trend displays additionally the SIMATIC WinCC Server for Runtime Professional
- Alarm logging option must be installed on the server. For the clients in the basic
- Report system configuration, a SIMATIC WinCC Client for Runtime Professional
- Archiving (option) license is sufficient.
- Recipe management (option)
• Universally scalable ■ Function
- Expandable from single station to client-server configura-
tions Visualization via Windows-compliant user interface
- Process visualization via the web with the Made up of parameterizable screen objects and faceplates
WinCC WebNavigator created on a project-specific basis:
• Open standards for easy integration • Numeric and alphanumeric input/output fields
- Efficient real-time database MS SQL Server
- Open for application modules with ActiveX controls • Static text and graphic display plus vector graphics 4
- Visual Basic for Applications for individual expansions • Dynamizable graphics from HMI symbol library
- OPC for cross-vendor communication • Bar graph, trend curve graph with scroll and zoom function as
• Part of the Totally Integrated Automation Portal well as read line
- Direct access to the tag and message configuration of the • Signal-specific text and graphic lists
SIMATIC controller
- Excellent support of the new SIMATIC S7-1500 controller • Buttons and switches for operator-process communication
With symbolic addressing • Editing fields for process values (signals)
Access to the new memory-optimized data blocks • Analog display, slider as example for further screen objects
New alarm and diagnostics concept
- Integrated diagnostic functions for increasing productivity • Project-specific faceplates created from basic objects of the
system
■ Application • Graphic displays for various standard graphic formats,
e.g. bitmaps, .jpg, .wmf
SIMATIC WinCC Runtime Professional is designed for visual- Alarms and messages
ization and operation of processes, manufacturing cycles,
machines and plants. With its powerful process interface, • Discrete alarms and analog alarms, as well as event-driven
especially to the SIMATIC family, and the secure data logging, Alarm-S/Alarm-D message procedure with SIMATIC S7
WinCC Runtime Professional enables solutions for the process • The new alarm and diagnostics concept of the S7-1500
control. controller is also supported
The sector-neutral basic system enables universal usage in all • Freely-definable alarm classes for definition of acknowl-
automation applications. edgment response and display of alarm events
SIMATIC WinCC Runtime Professional can be used in combi- Logging of alarms and process values 1)
nation with the following HMI devices: • Signaling system for detecting and archiving events with
SIMATIC PCs: display and control options according to DIN 19235
• SIMATIC Panel PC: HMI IPC477C, IPC477D, Panel PC 577B, • Process logging for the acquisition, compression and storage
HMI IPC577C, Panel PC 677B, HMI IPC677C of measured values
• SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B, • Online evaluation of process value and alarm logs
IPC627C, IPC827C 1)
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
• SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D, purchased separately. For further information, refer to "WinCC options".
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
• Standard PC
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
■ Function (continued)
Recipes 1) Open communication between HMI systems and
• Generation of data records for machine data or production with higher-level systems
data • OPC-Server
• Display or entry of data records via a configurable screen Use of the visualization system as a data server (OPC-Server)
object or via process screens distributed within the project for higher-level automation components such as control
systems or systems in the office sector
• Transmission of data records from or to the controller - OPC-DA-Server: tags, e.g. process values
• Import/export of data records for further processing with other - OPC-HDA-Server: logged process values
tools (e.g. MS Excel) - OPC-A&E-Server: Alarms
- OPC-XML-DA-Server: tags, e.g. process values
Documentation of process data, alarm events, and recipes - OPC-UA-DA-Server: tags, e.g. process values
• Time or event-driven report output • OLE DB Server
• User-definable layout - Standardized and user-friendly access to WinCC log data
Flexible expansion by means of Visual Basic Script and ANSI-C (MS SQL Server 2005).
- Access is via the OLE-DB Provider supplies all WinCC log
• Programming interfaces for individual access to data and data available along with the accompanying process values,
functions of WinCC Runtime Professional and for the as well as alarm and user texts.
integration in user programs with VBA, VB Script, C-API, - The WinCC OLE-DB provider also supports analysis
C-Script (ANSI-C) functions such as minimum, maximum, alarm hit list, etc.
Language support for multilingual projects • WinCC WebNavigator for Runtime Professional 1)
• Language-dependent texts and graphics - Option for SIMATIC WinCC Runtime Professional for
operating and monitoring plants over the Internet, company
• Language selection during runtime Intranet or LAN.
Onboard controller connection to many different controllers - Configuration from a web server with the SIMATIC WinCC
Runtime Professional software as a single-user, client or
• Communication via native drivers and standard OPC channel
4
server version and a web client that enables operator control
• For communication with subordinate controls and monitoring of a current WinCC Runtime Professional
(SIMATIC protocols, PROFIBUS DP, PROFIBUS FMS, DDE project via an Internet browser with ActiveX support. The
and OPC server included in the scope of delivery) WinCC basic system does not have to be installed on the
client computer.
• WinCC DataMonitor for Runtime Professional 1)
- The WinCC DataMonitor is used for displaying and evalu-
ating current process states and historical data on office PCs
using standard tools such as Microsoft Internet Explorer or
Microsoft Excel.
The DataMonitor Client is supported by a web server with
current and historic process data and alarms. All staff
ranging from machine operators to corporate managers can
use the DataMonitor to obtain information.
1) Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
Note:
In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past:
Size of swap file = 3 x size of RAM.
For further information, refer to your Windows documentation.
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
■ Technical specifications
The following tables of system limits provide assistance in SIMATIC WinCC
estimating whether a specific project is still within the system Runtime Professional
limitations for WinCC Runtime Professional. The stated maximum Logs
values are not additive.
Trend views per screen 25
We cannot guarantee proper functioning of configurations that
Trends per trend view 80
make full use of all system limits on the HMI devices. In addition
to the limitations specified, allowances must be made for restric- Tables per screen 25
tions in configuration memory resources. Columns per table 12
Values per table 30 000
SIMATIC WinCC
Runtime Professional Logs per single-user station/server 100
User text blocks per alarm line 10 Trends per trend view 80
Alarms per long-term log list 1 000 2) Web clients in a system 50 10)
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional