HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Overview ■ Design
PC-based operator control and monitoring system for visual- SIMATIC WinCC Runtime Professional is available as a software
ization and operator control of processes, production flows, package with 128, 512, 2 048, 4 096, 8 192, 65 536 PowerTags.
machines and plants in all sectors – from the simple single-user
station through to distributed multi-user systems and cross- PowerTags are data points that are connected to controllers or
location solutions with web clients. other data sources via a WinCC Runtime Professional channel.
Up to 32 alarms can be obtained from one data point. Moreover,
SIMATIC WinCC Runtime Professional is the information hub for internal tags without coupling are available for additional system
corporation-wide vertical integration. SIMATIC WinCC Runtime performance.
Professional is configured with the SIMATIC WinCC Professional
configuration software. WinCC Runtime Professional also contains 500 archive tags.
Additional archive licenses can be obtained for greater quantity
structures.
■ Benefits
Licenses for a multi-user configuration
• Functions for all visualization tasks:
- Operator functions The system software with the required number of PowerTags and
- Graphics and trend displays additionally the SIMATIC WinCC Server for Runtime Professional
- Alarm logging option must be installed on the server. For the clients in the basic
- Report system configuration, a SIMATIC WinCC Client for Runtime Professional
- Archiving (option) license is sufficient.
- Recipe management (option)
• Universally scalable ■ Function
- Expandable from single station to client-server configura-
tions Visualization via Windows-compliant user interface
- Process visualization via the web with the Made up of parameterizable screen objects and faceplates
WinCC WebNavigator created on a project-specific basis:
• Open standards for easy integration • Numeric and alphanumeric input/output fields
- Efficient real-time database MS SQL Server
- Open for application modules with ActiveX controls • Static text and graphic display plus vector graphics 4
- Visual Basic for Applications for individual expansions • Dynamizable graphics from HMI symbol library
- OPC for cross-vendor communication • Bar graph, trend curve graph with scroll and zoom function as
• Part of the Totally Integrated Automation Portal well as read line
- Direct access to the tag and message configuration of the • Signal-specific text and graphic lists
SIMATIC controller
- Excellent support of the new SIMATIC S7-1500 controller • Buttons and switches for operator-process communication
With symbolic addressing • Editing fields for process values (signals)
Access to the new memory-optimized data blocks • Analog display, slider as example for further screen objects
New alarm and diagnostics concept
- Integrated diagnostic functions for increasing productivity • Project-specific faceplates created from basic objects of the
system
■ Application • Graphic displays for various standard graphic formats,
e.g. bitmaps, .jpg, .wmf
SIMATIC WinCC Runtime Professional is designed for visual- Alarms and messages
ization and operation of processes, manufacturing cycles,
machines and plants. With its powerful process interface, • Discrete alarms and analog alarms, as well as event-driven
especially to the SIMATIC family, and the secure data logging, Alarm-S/Alarm-D message procedure with SIMATIC S7
WinCC Runtime Professional enables solutions for the process • The new alarm and diagnostics concept of the S7-1500
control. controller is also supported
The sector-neutral basic system enables universal usage in all • Freely-definable alarm classes for definition of acknowl-
automation applications. edgment response and display of alarm events
SIMATIC WinCC Runtime Professional can be used in combi- Logging of alarms and process values 1)
nation with the following HMI devices: • Signaling system for detecting and archiving events with
SIMATIC PCs: display and control options according to DIN 19235
• SIMATIC Panel PC: HMI IPC477C, IPC477D, Panel PC 577B, • Process logging for the acquisition, compression and storage
HMI IPC577C, Panel PC 677B, HMI IPC677C of measured values
• SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B, • Online evaluation of process value and alarm logs
IPC627C, IPC827C 1)
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
• SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D, purchased separately. For further information, refer to "WinCC options".
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
• Standard PC

Siemens ST 80 / ST PC · 2013 4/19


© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Function (continued)
Recipes 1) Open communication between HMI systems and
• Generation of data records for machine data or production with higher-level systems
data • OPC-Server
• Display or entry of data records via a configurable screen Use of the visualization system as a data server (OPC-Server)
object or via process screens distributed within the project for higher-level automation components such as control
systems or systems in the office sector
• Transmission of data records from or to the controller - OPC-DA-Server: tags, e.g. process values
• Import/export of data records for further processing with other - OPC-HDA-Server: logged process values
tools (e.g. MS Excel) - OPC-A&E-Server: Alarms
- OPC-XML-DA-Server: tags, e.g. process values
Documentation of process data, alarm events, and recipes - OPC-UA-DA-Server: tags, e.g. process values
• Time or event-driven report output • OLE DB Server
• User-definable layout - Standardized and user-friendly access to WinCC log data
Flexible expansion by means of Visual Basic Script and ANSI-C (MS SQL Server 2005).
- Access is via the OLE-DB Provider supplies all WinCC log
• Programming interfaces for individual access to data and data available along with the accompanying process values,
functions of WinCC Runtime Professional and for the as well as alarm and user texts.
integration in user programs with VBA, VB Script, C-API, - The WinCC OLE-DB provider also supports analysis
C-Script (ANSI-C) functions such as minimum, maximum, alarm hit list, etc.
Language support for multilingual projects • WinCC WebNavigator for Runtime Professional 1)
• Language-dependent texts and graphics - Option for SIMATIC WinCC Runtime Professional for
operating and monitoring plants over the Internet, company
• Language selection during runtime Intranet or LAN.
Onboard controller connection to many different controllers - Configuration from a web server with the SIMATIC WinCC
Runtime Professional software as a single-user, client or
• Communication via native drivers and standard OPC channel
4
server version and a web client that enables operator control
• For communication with subordinate controls and monitoring of a current WinCC Runtime Professional
(SIMATIC protocols, PROFIBUS DP, PROFIBUS FMS, DDE project via an Internet browser with ActiveX support. The
and OPC server included in the scope of delivery) WinCC basic system does not have to be installed on the
client computer.
• WinCC DataMonitor for Runtime Professional 1)
- The WinCC DataMonitor is used for displaying and evalu-
ating current process states and historical data on office PCs
using standard tools such as Microsoft Internet Explorer or
Microsoft Excel.
The DataMonitor Client is supported by a web server with
current and historic process data and alarms. All staff
ranging from machine operators to corporate managers can
use the DataMonitor to obtain information.
1) Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".

4/20 Siemens ST 80 / ST PC · 2013


© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Function (continued) ■ Integration


WinCC ControlDevelopment Integration in company-wide solutions
for extending the functionality by adding own Controls 1) (IT and business integration)
• Development of proprietary VB.net or C# Controls for
integration in WinCC Runtime Professional WinCC Runtime Professional is strictly based on Microsoft
technology, which provides for the greatest possible compati-
1)
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
bility and integration ability. ActiveX and .net Controls support
purchased separately. For further information, refer to "WinCC options". technology and sector-specific expansions.
Cross-manufacturer communication is also a simply exercise.
System prerequisites SIMATIC WinCC The reason: WinCC Runtime Professional can be used as an
Runtime Professional OPC client and server, and in addition to access to current
Processor type (min.) 1) • Windows XP: 2.5 GHz P4 or process values, it also supports standards such as OPC HDA
comparable, Pentium M, 1.6 GHz (Historical Data Access), OPC Alarm & Events, OPC UA Data
or comparable Access and OPC XML Data Access. Just as important: Visual
• Windows 7 (32-bit): 3.5 GHz P4 Basic Scripting (VBS) as an easy-to-learn, open Runtime
or comparable, dual core language. If desired, professional application developers can
• Windows Server 2003: 3 GHz P4 also use ANSI-C.
or comparable
• Windows Server 2008: 3 GHz P4
WinCC Runtime Professional integrates a powerful and scalable
or comparable, dual/multi core Historian function based on the Microsoft SQL Server in the
basic system.
RAM (min.) 2) 2 GB
Free hard disk space 3) 2 GB on system drive "C:"
Thus the user is given all possibilities: from high-performance
archiving of current process data, to long-term archiving with
Operating systems 32-bit operating systems high data compression, through to a central information
• Microsoft Windows XP Professional
SP3
turntable in form of a company-wide Process Historian.
• Windows Embedded Standard Open interfaces form the basis for an effective IT and business
2009 (for IPC / IPC2x7D, HMI
IPC4x7C only)
• Microsoft Windows Server 2003 R2
integration.
4
StdE SP2
• Microsoft Windows Server 2008
StdE SP2
• Microsoft Windows 7 Professional
SP1
• Microsoft Windows 7 Enterprise
SP1
• Microsoft Windows 7 Ultimate SP1
• Microsoft Windows Embedded
Standard 7 SP1 (for IPC / IPC2x7D,
HMI IPC4x7C only)
64-bit operating systems
• Microsoft Windows 7 Professional
SP1
• Microsoft Windows 7 Enterprise
SP1
• Microsoft Windows 7 Ultimate SP1
• Microsoft Windows Server 2003 R2
StdE SP2
• Microsoft Windows Server 2008 R2
Standard Edition SP1
Graphics card 32 MB RAM, 24 bit color depth
Network Ethernet 10 Mbit/s or higher
Optical drive DVD-ROM
1) In combination with options, more powerful systems may be required
2) The required RAM is determined primarily by the size of the graphics used.
3) Without taking archives into account.

Note:
In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past:
Size of swap file = 3 x size of RAM.
For further information, refer to your Windows documentation.

Siemens ST 80 / ST PC · 2013 4/21


© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Technical specifications
The following tables of system limits provide assistance in SIMATIC WinCC
estimating whether a specific project is still within the system Runtime Professional
limitations for WinCC Runtime Professional. The stated maximum Logs
values are not additive.
Trend views per screen 25
We cannot guarantee proper functioning of configurations that
Trends per trend view 80
make full use of all system limits on the HMI devices. In addition
to the limitations specified, allowances must be made for restric- Tables per screen 25
tions in configuration memory resources. Columns per table 12
Values per table 30 000
SIMATIC WinCC
Runtime Professional Logs per single-user station/server 100

Alarms Log tags per single-user station/ 8 000


server 7)
Configurable alarms 20 000
per server/single user Trends

PowerTags per alarm line 10 Trend views per image 25

User text blocks per alarm line 10 Trends per trend view 80

Alarm classes 18 User administration


(incl. system alarm classes) Number of user groups 128
Alarm types 16 Number of user rights 999
Alarm priorities 17 (0...16) Number of users 128
Alarms in Runtime Configurations – Quantity structure
Alarms per alarm log Unlimited 1) in a multi-user system

4 Alarms per short-term log list 1 000 WinCC clients in a system 32 8) 9)

Alarms per long-term log list 1 000 2) Web clients in a system 50 10)

Alarms per alarm display 5 000 3)


Screens 1)
Limited by system resources.
Objects per screen 4) 3 0005) 2)
On single-user station or server or on client per server if "LongTimeArchive-
Levels per screen 32 Consistency" is set to "No". On single-user station, server, or client if
"LongTimeArchiveConsistency" is set to "Yes".
Screens per project 1 000 5) 3)
On single-user station or server or on client per server.
Instances of fixed faceplates 31 instances of the same picture 4)
The number and complexity of the objects affect the performance.
in a process screen type
5)
Limited by system resources.
Screen size in pixels 10 000 x 10 000 6)
The sum of the number of recipe elements and number of data records
Nesting levels of screen objects 20 must not exceed a value of 320,000.
7)
Recipes Dependent on the Logging Powerpack used for the log tags.
500 log tags are contained in the basis version.
Number of recipes 1 000 5) 8)
If the server is also used as an operating unit, the number of clients for this
Number of recipe elements 500 6) server is reduced to four.
9)
Number of recipe data records 3 000 6) Mixed configuration: 32 Clients + 3 Web Clients
10)
5) Mixed configuration: 50 Web Clients + 1 WinCC Client
Number of views Unlimited

4/22 Siemens ST 80 / ST PC · 2013


© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Ordering data Order No. Order No.


Basic software Powerpacks
SIMATIC WinCC SIMATIC WinCC
Runtime Professional V12 SP1 Runtime Professional V12 and
SIMATIC WinCC
For PC systems; Runtime Professional ASIA V12
incl. software options 1),
language/script versions: Single license, license key only on
DE, EN, FR, IT, ES USB sticks for PowerTags from
Single License, on DVD • 128 to 512 PowerTags 6AV2105-2BD02-0BD0
incl. licensing, on USB stick, for: • 512 to 2048 PowerTags 6AV2105-2DF02-0BD0
• 128 PowerTags 6AV2105-0BA02-0AA0 • 2048 to 4096 PowerTags 6AV2105-2FH02-0BD0
• 512 PowerTags 6AV2105-0DA02-0AA0 • 4096 to 8192 PowerTags 6AV2105-2HK02-0BD0
• 2048 PowerTags 6AV2105-0FA02-0AA0 • 8192 to 65536 PowerTags 6AV2105-2KM02-0BD0
• 4096 PowerTags 6AV2105-0HA02-0AA0
• 8192 PowerTags 6AV2105-0KA02-0AA0 Online software delivery (OSD) 3)
• 65535 PowerTags 6AV2105-0MA02-0AA0 Single license, license key
download only.
Incl. 500 archive tags each E-mail address required
Online software delivery (OSD) 3) for the delivery.
• 128 to 512 PowerTags 6AV2105-2BD02-0BJ0
Single license, software and
license key download. • 512 to 2048 PowerTags 6AV2105-2DF02-0BJ0
E-mail address required • 2048 to 4096 PowerTags 6AV2105-2FH02-0BJ0
for the delivery. • 4096 to 8192 PowerTags 6AV2105-2HK02-0BJ0
• 128 PowerTags 6AV2105-0BA02-0AH0 • 8192 to 65536 PowerTags 6AV2105-2KM02-0BJ0
• 512 PowerTags 6AV2105-0DA02-0AH0 Upgrades WinCC V11
• 2048 PowerTags 6AV2105-0FA02-0AH0 to WinCC V12 SP1
• 4096 PowerTags 6AV2105-0HA02-0AH0
SIMATIC WinCC
• 8192 PowerTags 6AV2105-0KA02-0AH0
4
Runtime Professional V11 to
• 65535 PowerTags 6AV2105-0MA02-0AH0 SIMATIC WinCC
Incl. 500 archive tags each Runtime Professional V12 SP1
and SIMATIC WinCC
SIMATIC WinCC Runtime Professional ASIA V11
Runtime Professional ASIA to SIMATIC WinCC
V12 SP1 Runtime Professional ASIA
V12 SP1
For PC systems;
incl. software options 1), Single license, on DVD
language/script versions: incl. licensing on USB stick
EN, CHs, CHt, KOR, JPN • SIMATIC WinCC Runtime 6AV2105-3BB02-0AE0
Single License, on DVD Professional 128 PowerTags
incl. licensing, for: V12 SP1
• 128 PowerTags 6AV2105-0BA12-0AA0 Upgrade V11 -> V12 SP1
• 512 PowerTags 6AV2105-0DA12-0AA0 • SIMATIC WinCC Runtime 6AV2105-3DD02-0AE0
• 2048 PowerTags 6AV2105-0FA12-0AA0 Professional 512 PowerTags
V12 SP1
• 4096 PowerTags 6AV2105-0HA12-0AA0
Upgrade V11 -> V12 SP1
• 8192 PowerTags 6AV2105-0KA12-0AA0
• SIMATIC WinCC Runtime 6AV2105-3FF02-0AE0
• 65535 PowerTags 6AV2105-0MA12-0AA0 Professional 2048 PowerTags
Incl. 500 archive tags each V12 SP1
Upgrade V11 -> V12 SP1
SIMATIC WinCC Client for • SIMATIC WinCC Runtime 6AV2105-3HH02-0AE0
Runtime Professional Professional 4096 PowerTags
• WinCC Client for 6AV2107-0DB02-0AA0 V12 SP1
Runtime Professional Upgrade V11 -> V12 SP1
• WinCC Client for 6AV2107-0DB02-0AH0 • SIMATIC WinCC Runtime 6AV2105-3KK02-0AE0
Runtime Professional Professional 8192 PowerTags
(form of delivery OSD 3)) V12 SP1
• WinCC Client for 6AV2107-0DB12-0AA0 Upgrade V11 -> V12 SP1
Runtime Professional ASIA • SIMATIC WinCC Runtime 6AV2105-3MM02-0AE0
Professional 65536 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
1) Runtime licenses for WinCC Runtime Professional options must be
purchased separately for each target system.
2) Each including 1 upgrade license to the WinCC Runtime Professional
options.
3) Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC · 2013 4/23

You might also like